hmwpe cathodic protection line card - agavewire.com

1
Give Us A Call 1.800.690.3408 www.AgaveWire.com P) 800.690.3408 F) 469.547.4242 [email protected] Annealed stranded bare copper conforming to ASTM B-8. A high molecular weight polyethylene (HMW/PE) jacket insulation conforming to ASTM D 1248. All cathodic protection cable products are recognized by UL. USED IN CATHODIC PROTECTION SYSTEMS FOR: - Pipelines - Well Casings - Oil Tanks - Underground or Submerged - Steel Pipe Metallic Objects/Structures FEATURES: - Custom Print Available - Crush Resistant - Direct Burial - Oil Resistant - Abrasion Resistant - UL Listed Conductor Stranding Insulation Material Insulation Thickness Finished Nominal O.D. Appx Weight/1,000 ft. Operating Temperature Operating Voltage ACPT-1/OT ACPT-0807 ACPT-0607 ACPT-0407 ACPT-0207 600V 600V 600V 600V 600V 75ºC 75ºC 75ºC 75ºC 75ºC 411 LBS 262 LBS 182 LBS 125 LBS 88 LBS 0.623” 0.512” 0.452” 0.404” 0.366” 0.125” 0.110” 0.110” 0.110” 0.110” HMW/PE HMW/PE HMW/PE HMW/PE HMW/PE 19/.0745 Stranded BC 7/.0486 Stranded BC 7/.0612 Stranded BC 7/.0772 Stranded BC 7/.0974 Stranded BC 1 O/T Stranded Bare Copper 8 AWG Stranded Bare Copper 6 AWG Stranded Bare Copper 4 AWG Stranded Bare Copper 2 AWG Stranded Bare Copper CATHODIC PROTECTION PRODUCTS TYPE TW & THHN ALSO AVAILABLE HMWPE CATHODIC PROTECTION CABLE (1/OT) (2 AWG) (4 AWG) (6 AWG) (8 AWG)

Upload: others

Post on 03-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Give Us A Call1.800.690.3408

www.AgaveWire.com

P) 800.690.3408 F) 469.547.4242 [email protected]

Annealed stranded bare copper conforming to ASTM B-8. A high molecular weight polyethylene (HMW/PE) jacket insulation conforming to ASTM D 1248. All cathodic protection cable products are recognized by UL.

USED IN CATHODIC PROTECTION SYSTEMS FOR: - Pipelines - Well Casings - Oil Tanks - Underground or Submerged - Steel Pipe Metallic Objects/Structures

FEATURES: - Custom Print Available - Crush Resistant - Direct Burial - Oil Resistant - Abrasion Resistant - UL Listed

Conductor

Stranding

Insulation Material

Insulation Thickness

Finished Nominal O.D.

Appx Weight/1,000 ft.

Operating Temperature

Operating Voltage

ACPT-1/OT ACPT-0807ACPT-0607ACPT-0407ACPT-0207

600V 600V 600V 600V 600V

75ºC 75ºC 75ºC 75ºC 75ºC

411 LBS 262 LBS 182 LBS 125 LBS 88 LBS

0.623” 0.512” 0.452” 0.404” 0.366”

0.125” 0.110” 0.110” 0.110” 0.110”

HMW/PE HMW/PE HMW/PE HMW/PE HMW/PE

19/.0745Stranded BC

7/.0486Stranded BC

7/.0612Stranded BC

7/.0772Stranded BC

7/.0974Stranded BC

1 O/T StrandedBare Copper

8 AWG StrandedBare Copper

6 AWG StrandedBare Copper

4 AWG StrandedBare Copper

2 AWG StrandedBare Copper

CATHODICPROTECTIONPRODUCTS

TYPE TW & THHN ALSO AVAILABLE

HMWPE CATHODIC PROTECTION CABLE

(1/OT) (2 AWG) (4 AWG) (6 AWG) (8 AWG)