hoffmann ii micro external fixation system · 2017-06-12 · 5065-3-615 5065-4-520 ref 36mm 45mm...
TRANSCRIPT
Hoffmann II Micro External Fixation System
Indications for the Hand
50752000 C5007 Hoffmann II Micro Brochure.indd 150752000 C5007 Hoffmann II Micro Brochure.indd 1 21.1.2008 9:34:50 Uhr21.1.2008 9:34:50 Uhr
22
A variety of frames can be ana-tomically built with only 4 basic components which are based on the patented Hoffmann II “Click” Mechanism offering surgeons quick and easy solutions.
This system is compatible with the Hoffmann II Compact System giving the surgeon Complete Solutions for the Hand, Wrist, and Forearm.
2.0mm and 1.65mm Self-Drill-ing Self-Tapping Apex Pins allow pin insertion without pre-drilling which will Save Time in O.R.
The instrumentation is Simple and User-Friendly, and the system is Color Coded, so there is no lost time or confusion in the O.R.
Features & Benefits
50752000 C5007 Hoffmann II Micro Brochure.indd 250752000 C5007 Hoffmann II Micro Brochure.indd 2 21.1.2008 9:34:52 Uhr21.1.2008 9:34:52 Uhr
33
The system offers Independent Pin Placement to adapt to the anatomy which is needed to ad-dress complex fractures and severe soft-tissue damage.
Low Profi le and Light Weight frame assemblies offer added com-fort to the patient.
The system is designed to facilitate fracture alignment and Reduction After Frame Assembly offering the surgeon more Freedom and Flexibility when building the frame.
Post-operative Corrections can easily be made while the frame is in place to insure proper anatomi-cal positioning throughout the healing process.
Features & Benefits
50752000 C5007 Hoffmann II Micro Brochure.indd 350752000 C5007 Hoffmann II Micro Brochure.indd 3 21.1.2008 9:34:59 Uhr21.1.2008 9:34:59 Uhr
4
In 1938, Raoul Hoffmann, a Swiss
surgeon from Geneva, Switzerland,
designed a revolutionary External
Fixation System. The basic features of
this system were its modular design
and the ability to reduce fractures or
to make post operative corrections to
the alignment of fragments in three
planes with the frame in situ. The
Original Hoffmann System underwent
considerable design improvements
over the years. Then in the late 90’s, a
group of renowned design surgeons1
and Stryker engineers developed the
innovative Hoffmann II and
Hoffmann II Compact Systems. These
systems signifi ed a giant step forward
in the treatment of bone fractures with
modular external fi xation frames.
Indeed, thanks to the light weight and
non bulky components, the Hoffmann II
Systems provide surgeons an unlimited
versatility, simplicity, and an unequaled
ease of use. The Hoffmann II Micro
System capitalizes on the experience
acquired during several decades with the
original Hoffmann System and with the
Hoffmann II and Hoffmann II Compact
Systems. It is made of stainless steel and
carbon composite materials to provide
optimal low profi le high resistance
features, and it has been designed to
answer the growing needs of small bone
injuries by ensuring ease of use,
versatility and patient comfort.
Introduction
1 Dr. Gernot Asche, Andy Burgess M.D., Prof. Franz Burny, Mr. Charles M. Court-Brown, Prof. Erkki O. Karaharju, Loren Latta Ph.D., Prof. David Seligson M.D., Dr. Gregory Zych M.D.
50752000 C5007 Hoffmann II Micro Brochure.indd 450752000 C5007 Hoffmann II Micro Brochure.indd 4 21.1.2008 9:35:04 Uhr21.1.2008 9:35:04 Uhr
5
Relative Indications
The Hoffmann II Micro System is indi-cated for hand fractures. It is particularly suited for the following indications:
- Articular fractures- Comminuted Fractures- Severe open fractures (Grade 3)- Rolando fractures- Non unions and delayed unions- Fractures associated with infection- Acute Corrective Osteotomies- Bennett’s fractures- Burns and Contractures- Pathologic fractures- Small Joint Arthrodesis
Hoffmann II Micro Standard Frame Guide
Due to the versatility of the Hoffmann II Micro System, there is a virtually unlimited number of frame constructs.The surgeon has the choice to make any frame that will best heal the fracture. The following are the standard frames which are explained in detail in the Hoffmann II Micro Technical Guide
- Mid-Shaft Fracture of the Proximal Phalanx of the Index Finger
- Metaphaseal Fracture of the Proximal Phalanx of the Index Finger
- Inter-Articular Fracture of the Fifth Metacarpal with severe soft-tissue damage.
Relative Contraindications
- Patients with a compromised immune system.
- Non compliant patients who would not be able to ensure proper pin care.
- Pre-existing internal fi xation that prohibits proper pin placement
- Bone pathology precluding pin fi xation
Indications & Contraindications
50752000 C5007 Hoffmann II Micro Brochure.indd 550752000 C5007 Hoffmann II Micro Brochure.indd 5 21.1.2008 9:35:08 Uhr21.1.2008 9:35:08 Uhr
6
Related Stryker Products
The Hoffmann II Compact External Fixation System gives the surgeon the ability to treat a variety of fractures of the wrist, forearm, and foot. This low-profi le, modular fi xator easily adapts to the patient’s anatomy and soft tissues. For more details, contact your local Stryker Representative and ask for the Hoffmann II Compact Brochure (REF 5075-1-500).
The VariAx Distal Radius Plating System represents the Next Generation of Bone Fixation for your Distal Radius Fracture Needs. It is designed to offer the most comprehensive selection of plates, screws, pegs and unique instrumentation necessary to optimally maintain the stability of the distal radius lesion, while providing your surgical staff a user-friendly module layout.
The VariAx Distal Radius Plating System
Hoffmann II Compact
Hoffmann II Micro Lengthener
Based on the unique Hoffmann IIMicro System for fracture management, Stryker has developed the Hoffmann II Micro Lengthener for metacarpal or phalangeal lengthening.The lengthener offers the same versatility and ease-of-use which makes the Hoffmann II Micro system a leader in External Fixation for the Hand
50752000 C5007 Hoffmann II Micro Brochure.indd 650752000 C5007 Hoffmann II Micro Brochure.indd 6 21.1.2008 9:35:14 Uhr21.1.2008 9:35:14 Uhr
7
Related Stryker Products
The Stryker Hand Plating System is a truly comprehensive system which offers you the locking and non-locking options necessary to treat a full range of hand and wrist fractures which present daily.
Stryker Hand Plating System
HydroSet Injectable HA Bone Substitute
Fracture gaps are often seen in comminuted Distal Radius fractures. Some surgeons prefer to use bone substitutes to fi ll these gaps. Stryker offers an innovative HA Bone Substitute with HydroSet.
The injectable self-setting calcium phosphate material allows the surgeon to fi ll bone voids or gaps of the skeletal system (i.e., extremities, craniofacial, spine, and pelvis). These defects may be surgically created or osseous defects created from traumatic injury to the bone.
HydroSet is delivered in 3, 5, 10, or 15cc quantities. 3cc and 5cc are normally suitable for voids in the Distal Radius.
50752000 C5007 Hoffmann II Micro Brochure.indd 750752000 C5007 Hoffmann II Micro Brochure.indd 7 21.1.2008 9:35:18 Uhr21.1.2008 9:35:18 Uhr
8
Ordering Information - Implants
Warning:Bone Screws referenced in this material are not approved for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine.
5079-6-030
5079-6-040
5079-6-050
5079-6-060
5079-6-090
5079-6-120
5079-6-150
5079-5-030
5079-5-040
5079-5-050
5079-5-060
5079-5-090
5079-5-120
5079-5-150
REF Diameter
30mm
40mm
50mm
60mm
90mm
120mm
150mm
30mm
40mm
50mm
60mm
90mm
120mm
150mm
Total Length
Connecting Rods
Carbon Connecting Rod
Carbon Connecting Rod
Carbon Connecting Rod
Carbon Connecting Rod
Carbon Connecting Rod
Carbon Connecting Rod
Carbon Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Stainless Steel Connecting Rod
Description
Couplings and Clamps
4960-1-010
REF
3mm / 3mm
Diameter
1.65mm–2mm / 3mm4960-1-020
4960-1-060
Rod to Rod Coupling
Description
5mm / 3mm
Pin to Rod Coupling
Multi-Pin Clamp —
Rod to Rod Coupling
90° Multi-Pin Clamp
4960-2-020
4960-2-030 —
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
3mm
50752000 C5007 Hoffmann II Micro Brochure.indd 850752000 C5007 Hoffmann II Micro Brochure.indd 8 21.1.2008 9:35:45 Uhr21.1.2008 9:35:45 Uhr
9
2mm Self Drilling / Self Tapping Apex Half-Pins
5080-2-012
5080-2-020
REF
45mm
45mm
Total Length
12mm
20mm
Thread Length
2mm
2mm
Shaft Diameter
390142
390152
390162
390164
REF
1.0mm
1.2mm
1.4mm
1.6mm
Diameter
150mm
150mm
150mm
150mm
Total Length
K-Wires
K-Wire
K-Wire
K-Wire
K-Wire
Description
5080-1-612
5080-1-620
REF
45mm
45mm
Total Length
12mm
20mm
Thread Length
1.65mm Self Drilling / Self Tapping Apex Half-Pins
1.65/2mm
1.65/2mm
Thread/Shaft Diameter
5065-3-615
5065-4-520
REF
36mm
45mm
Total Length
15mm
20mm
Thread Length
2mm Blunt Apex Half-Pins
2mm
2mm
Shaft Diameter
Ordering Information - Implants
50752000 C5007 Hoffmann II Micro Brochure.indd 950752000 C5007 Hoffmann II Micro Brochure.indd 9 21.1.2008 9:35:59 Uhr21.1.2008 9:35:59 Uhr
10
4960-9-040
REF
Drill / Pin Insertion Guide
Description
4960-9-904 Storage Case Lid
5084-4-044 4mm Spanner Wrench
4940-9-030 5mm Wrench / 3mm–4mm Pin Driver
4960-9-020 2mm/1.65mm Pin Driver
4960-9-030 4mm Nut Wrench
Ordering Information - Instruments
4960-9-903 Storage Case Upper Insert
4960-9-902 Storage Case Lower Insert
4960-9-901 Storage Case Base
50752000 C5007 Hoffmann II Micro Brochure.indd 1050752000 C5007 Hoffmann II Micro Brochure.indd 10 21.1.2008 9:36:03 Uhr21.1.2008 9:36:03 Uhr
11
Notes
50752000 C5007 Hoffmann II Micro Brochure.indd 1150752000 C5007 Hoffmann II Micro Brochure.indd 11 21.1.2008 9:36:12 Uhr21.1.2008 9:36:12 Uhr
Stryker Trauma AGBohnackerweg 1CH-2545 SelzachSwitzerland
www.osteosynthesis.stryker.com
The information presented in this brochure is intended to demonstrate a Stryker product. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which products and techniques to use with their patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area.
Stryker Corporation or its subsidiary owns the registered trademark: Stryker, Hoffmann, ApexStryker Corporation or its subsidiary owns, uses or has applied for the following trademarks: Compact, HydroSet, VariAx
Literature Number: 5075-2-000LOT C5007
Copyright © 2007 Stryker
50752000 C5007 Hoffmann II Micro Brochure.indd 1250752000 C5007 Hoffmann II Micro Brochure.indd 12 21.1.2008 9:36:12 Uhr21.1.2008 9:36:12 Uhr