holtec’s vision for a centralized interim storage facility · 2015-07-30 · a generation ahead...

14
a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent Fuel Seminar January 16, 2013 Doug Weaver, Vice President of Licensing and Regulatory Affairs Technology Center located in Marlton, New Jersey U.S.A

Upload: others

Post on 25-Apr-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Holtec’s Vision for a Centralized Interim Storage FacilityINMM Spent Fuel Seminar

January 16, 2013

Doug Weaver, Vice President of Licensing and Regulatory Affairs

Technology Center locatedin Marlton, New Jersey U.S.A

Page 2: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Holtec’s Dry Storage &Transport Expertise

• Holtec offers a complete line of equipment for dry fuel storage and transportation

• 73 plants worldwide (48 in the U.S.) are under contract for use of Holtec’s dry storage systems

• Over 550 Holtec canisters have been successfully loaded

– This number grows by 70-90 canisters per year

2

Page 3: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Holtec’s Interim Storage Experience

3

Rendering of Private Fuel Storage

• Holtec gained valuable experience by supporting the licensing of PFS

• Holtec’s above ground storage system was approved for use

• Over 4,000 systems were expected to be used

• Demonstrated integrity even considering aircraft impact (F-16)

Page 4: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Why Do We Need Centralized Interim Storage?

• The path to a repository is uncertain

• CIS more than pays for itself

• Recommended by the BRC

• At 9 decommissioned sites, the SNFis all that prevents from releasing theland to other uses

• CIS is the shortest path for DOE to begin taking SNF and reduce the amount the government pays as a result of lawsuits (currently projected at $500M/yr. by 2020)

• Provides the most flexibility for recycling, research, and disposal4

Page 5: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

What is Holtec Doing?

• HI-STORM UMAX

– Underground Storage System– Based on an already certified

design - the HI-STORM 100U– Offsite doses are negligible – Provides the added security

against aircraft and other radiological sabotage

– Increased efficiency associated with standardization – An excellent solution for an ISFSI or CIS facility

5

Page 6: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Underground Maximum – “UMAX”

• HI-STORM FW* System Certified Components:

– HI-STORM Overpack

– HI-STORM VVM

– MPC-37– HI-TRAC VW*

• HI-STAR 190 Transport Package*FW – Flood and Wind

*VW – Variable Weight

66

Purpose-specific casks allow for optimized transfer, storage, and transport of the canisterized spent fuel

HI‐TRAC VWTransfer Cask

(Onsite Transfer/Transport)

HI‐STORM FW Storage Cask

(Aboveground Interim Storage)

HI‐STAR 190Transport Cask

(Offsite Transport)

MPC‐37Multi‐Purpose Canister(Storage/Transport) HI‐STORM UMAX

Storage Cask(Underground Interim Storage)

Page 7: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Constituent Parts of the VVM

7

• Closure Lid

• Cavity Enclosure Container (CEC)

• Divider Shell

Page 8: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

HI-STORM UMAX VVM

8

CECDivider Shell

Closure Lid

Page 9: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

MPC BEING LOWERED INTO THE VVM

9

Page 10: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

What’s Next? HI-STORM CIS

• Holtec plans to certify a system called HI-STORM CIS

– “CIS” is essentially a double capacity UMAX

– MPCs are stacked vertically underground

– Minimizes the site footprint

– Reduced construction and operating costs

– Ultra secure (e.g. against aircraft impact)

10

Page 11: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

HI-STORM CIS – A Closer Look

11

Centering andSpacing rings

HI-STORM CIS loadedwith two canisters

HI-STORM CIS loadedwith single canister

Page 12: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Turning Plans into Actions(Who will do the heavy lifting?)

• Holtec will support the prompt development of one or more consolidated interim storage sites

– Holtec is ready to partner with one or more communities to design and license a CIS

– Holtec believes an interim storage facility makes technical and economic sense

– CIS provides flexibility to deal with SNF in the future (recycling, research, cooling prior to shipment to repository)

12

Page 13: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Turning Plans into Actions(continued)

• Holtec supports the BRC’s recommendations– We urge Congressional action to adjust the

NWPA to allow for an interim storage facility– A new waste management organization with

access to the NWF is essential– We support the consent based approach for

siting, recognizing that Congress must act to provide incentives for potential host communities

– Potential host communities should dialog now with DOE on how they might meet the consent based standard

13

Page 14: Holtec’s Vision for a Centralized Interim Storage Facility · 2015-07-30 · a generation ahead by design Holtec’s Vision for a Centralized Interim Storage Facility INMM Spent

a generation ahead by design

Conclusions

• CIS is a viable short-term solution for SNF

• A facility could be available in a few years

• There are no technical impediments

• Holtec is certifying the needed systems now

• Holtec seeks to partner with host communities14