Home Inspection Report
1234 Street , Anywhere , OK 73075
Inspection Date:Tuesday June 18, 2019
Prepared For:John Doe
Prepared By:Green Light Properties, LLC
113 Christine StPauls Valley, OK 73075
Report Number:HI-000000
Inspector:Green Light Properties, LLC
License/Certification #:OK--70001869
1234 Street , Anywhere , OK 73075 Page 2
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Report OverviewScope of Inspection
All components designated for inspection in the InterNACHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.
Main Entrance FacesNorth
State of OccupancyVacant
Weather ConditionsCloudy
Recent Rain
Ground CoverDry
Approximate Age10-15 years
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 3
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Report SummaryItems Not Operating
-bathroom exhaust fans
Major ConcernsNone apparent
Potential Safety HazardsFurnace was producing high levels of carbon monoxide in flue, recommend a qualified HVAC technican examine
Improvement ItemsTemperature-Pressure relief valve extension should be 4"-6" off of the floor - this is a Safety Concern. Excessive rust present on vent pipe - recommend repairing and/or replacing Federal Pacific Panel Stab Lok® has a history of problems recommend a qualified electrician evaluate panel Some open junction boxes were in need of covers. Refrigerant line has missing insulation recommend installing insulation Ceiling fan is wobbling, recommend repair. Evidence of leaking insulated glass. Recommend repair/replacement of window
Items To MonitorSite Drainage
Deferred MaintenanceAll homes should be regularly maintained. Exterior caulking, maintaining proper site drainage, fixing minor issues AS they occur prevents problems. No home is perfect but routinely maintaining the home and all of its components ensure safety and longevity of the structure.
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 4
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Receipt/InvoiceGreen Light Properties, LLC113 Christine StPauls Valley, OK 730754052076415
Property Address1234 StreetAnywhere , OK 73075
Date: Jun 18, 2019 Inspection Number: HI-000000
Inspected By: Green Light Properties, LLC Payment Method: Credit Card
Client: John Doe
Inspection FeeHome Inspection $325.00Home Inspection discount ($35.00)Pay At Close Fee $25.00Home Energy Score $300.00Mold Testing $300.00
Total $915.00
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 5
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
GroundsService Walks
None Not Visible
Material X Concrete Flagstone Gravel Brick Other:
Condition X Satisfactory Marginal Poor Trip hazard Typical cracks Pitched towards homeSettling cracks Public sidewalk needs repair
Comments
Photos
Driveway/Parking
None Not Visible
Material X Concrete Asphalt Gravel/Dirt Brick Other:
Condition X Satisfactory Marginal Poor Settling Cracks Typical cracks Pitched towards homeTrip hazard Fill cracks and seal
Comments
Photos
Porch
X None Not Visible
Condition X Satisfactory Marginal Poor Railing/Balusters recommended
Support Pier X Concrete Wood Other:
Floor X Satisfactory Marginal Poor Safety Hazard
Comments
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 6
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
GroundsStoops/Steps
None
Material X Concrete Wood Other: Railing/Balusters recommended
Condition X Satisfactory Marginal Poor Safety Hazard Uneven risers Rotted/DamagedCracked Settled
Comments
Patio
None
Material X Concrete Flagstone Kool-Deck Brick Other:
Condition X Satisfactory Marginal Poor Settling cracks Trip hazardPitched towards home (see remarks) Drainage provided Typical cracks
Comments
Deck/Balcony
None Not Visible
Material X Wood Metal Composite Railing/Balusters recommended
Condition X Satisfactory Marginal Poor Wood in contact with soil
Finish X Treated Painted/Stained Other: Safety Hazard Improper attachment to houseRailing loose Not Applicable
Comments Deck appeared to be in satisfactory condition, applying a sealant on the wood will help prolong the life of the deck.
Deck/Patio/Porch Covers
None
Condition X Satisfactory Marginal Poor Posts/Supports need Repair Earth to wood contactMoisture/Insect damage
Recommend Metal Straps/Bolts/Nails/Flashing Improper attachment to house X None
Comments
Fence/Wall
Not evaluated None
Type Brick Block X Wood Metal Chain Link Rusted Vinyl
Condition Satisfactory X Marginal Poor Typical cracks Loose Blocks/Caps
Gate N/A X Satisfactory Marginal Poor Planks missing/damaged Operable: X Yes No
Comments Fencing was in need of maintenance repairs.
Landscaping affecting foundation
N/A
Negative Grade East West X North South Satisfactory X Recommend additional backfillRecommend window wells/covers Trim back trees/shrubberiesWood in contact with/improper clearance to soil
Comments Recommend maintaining a positive drainage slope away from the foundation.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 7
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Grounds
Retaining wall
X None
Material Brick Concrete Concrete block Other: Railroad ties Timbers
Condition Satisfactory Marginal Poor Safety Hazard Leaning/cracked/bowedDrainage holes recommended
Comments
Hose bibs
N/A
Condition X Satisfactory Marginal Poor No anti-siphon valve Recommend Anti-siphon valve
Operable X Yes No Not Tested Not On
Comments
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 8
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
RoofGeneral
Visibility None X All Partial Limited By:
Inspected From X Roof Ladder at eaves Ground With Binoculars
Photos
Style of Roof
Type X Gable Hip Mansard Shed Flat Other:
Pitch Low X Medium Steep Flat
Roof #1 Type:AsphaltLayers:1 Layer Age:5-10+Location:
Roof #2 X NoneType:Layers:Age:Location:
Roof #3 X NoneType:Layers:Age:Location:
Comments
Ventilation System
None N/A
Type X Soffit X Ridge Gable Roof Turbine Powered Other:
Comments
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 9
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Roof
Flashing
Material Not Visible X Galv/Alum Asphalt Copper Foam Rubber Lead Other:
Condition Not Visible X Satisfactory Marginal Poor Rusted MissingSeparated from chimney/roof Recommend Sealing Other:
Comments
Valleys
N/A
Material Not Visible X Galv/Alum Asphalt Lead Copper Other:
Condition X Not Visible Satisfactory Marginal Poor Holes Rusted Recommend Sealing
Comments
Condition of Roof Coverings
Roof #1 X Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Roof #2 X N/A Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Roof #3 X N/A Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Comments Roof was showing normal wear, but was in overall adequate condition.
Skylights
N/A Not Visible
Condition Cracked/Broken X Satisfactory Marginal Poor
Comments
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 10
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Roof
Plumbing Vents
Not Visible Not Present
Condition X Satisfactory Marginal Poor
Comments
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 11
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
ExteriorChimney(s)
None
Location(s) Middle of Roof
Viewed From X Roof Ladder at eaves Ground (Inspection Limited) With Binoculars
Rain Cap/Spark Arrestor X Yes No Recommended
Chase X Brick Stone Metal Blocks Framed
Evidence of Holes in metal X Cracked chimney cap X Loose mortar joints Flaking Loose brick RustNo apparent defects
Flue Tile X Metal Unlined Not Visible
Evidence of Scaling X Cracks Creosote Not evaluated X Have flue(s) cleaned and re-evaluatedRecommend Cricket/Saddle/Flashing No apparent defects
Condition Satisfactory X Marginal Poor Recommend Repair
Comments Flue covered with creosote, recommend cleaning and re-evaluate.
Photos
Gutters/Scuppers/Eavestrough
None
Condition Satisfactory X Marginal Poor Rusting Downspouts needed Recommend repair/replaceX Needs to be cleaned
Material Copper X Vinyl/Plastic Galvanized/Aluminum Other:
Leaking Corners Joints Hole in main run X No apparent leaks
Attachment Loose Missing spikes Improperly sloped X Satisfactory
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 12
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
ExteriorGutters/Scuppers/Eavestrough cont.
Extension needed X North South East X West N/A
Comments Insides of gutters are full of debris recommend cleaning Recommend adding downspout extensions to discharge away from the house. 5-6' extensions recommended.
Photos
Siding
Material Stone Slate Block/Brick Fiberboard X Fiber-cement Stucco EIFS* Not InspectedAsphalt Wood Metal/Vinyl Other: Typical cracks Peeling paint Monitor Wood rotLoose/Missing/Holes
Condition X Satisfactory Marginal Poor Recommend repair/painting
Comments Siding appeared to be all intact and in overall satisfactory condition.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 13
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Exterior
Trim
Material X Wood Fiberboard Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition X Satisfactory Marginal Poor
Comments
Soffit
None
Material Wood Fiberboard Aluminum/Steel X Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition Satisfactory X Marginal Poor
Comments
Fascia
None
Material X Wood Fiberboard Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition Satisfactory Marginal X Poor
Comments Fascia rotted/damaged, recommend repair
Flashing
None
Material Wood Fiberboard X Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other:
Condition X Satisfactory Marginal Poor
Comments
Caulking
None
Condition Satisfactory Marginal PoorX Recommend around windows/doors/masonry ledges/corners/utility penetrations
Comments Recommend caulking around windows, doors, corners, utility penetrations.
Windows/Screens
Condition X Satisfactory Marginal Poor Wood rot Recommend repair/paintingRecommend repair/replace damaged screens Failed/fogged insulated glass
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 14
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
ExteriorWindows/Screens cont.
Material Wood Metal X Vinyl Aluminum/Vinyl clad
Screens Torn Bent Not installed X Satisfactory
Comments
Storms Windows
X None X Not installed
Condition Satisfactory Broken/cracked Wood rot Recommend repair/painting
Material Wood Clad comb. Wood/Metal comb. Metal
Putty Satisfactory Needed N/A
Comments
Slab-On-Grade/Foundation
Foundation Wall Concrete block Poured concrete X Post-Tensioned concrete Not Visible Other:
Condition X Satisfactory Marginal Monitor Have Evaluated Not Evaluated
Concrete Slab X N/A X Not Visible Satisfactory Marginal Monitor Have Evaluated
Comments
Service Entry
Location X Underground Overhead
Condition X Satisfactory Marginal Poor Weather head/mast needs repair Overhead wires too low
Exterior receptacles X Yes No Operable: X Yes No Condition: X Satisfactory Marginal Poor
GFCI present X Yes No Operable: X Yes No Safety Hazard Reverse polarity Open ground(s)Recommend GFCI Receptacles
Comments Overhead wires sagging due to trees, recommend trimming trees and contacting utility company for repairs.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 15
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Exterior
Building(s) Exterior Wall Construction
Type Not Visible X Framed Masonry Other:
Condition X Not Visible Satisfactory Marginal Poor
Comments Building structure not visible due to siding, not evaluated.
Exterior Doors
Main Entrance N/A Weatherstripping: X Satisfactory Marginal Poor Missing Replace Door condition:X Satisfactory Marginal Poor
Patio N/A Weatherstripping: X Satisfactory Marginal Poor Missing Replace Door condition:Satisfactory X Marginal Poor
Rear door N/A Weatherstripping: Satisfactory X Marginal Poor Missing Replace Door condition:Satisfactory X Marginal Poor
Other door N/A Weatherstripping: Satisfactory X Marginal Poor Missing Replace Door condition:Satisfactory X Marginal Poor
Comments Door locks/latches not operable, recommend repair. Double cylinder dead bolt (keyed inside and outside) potential safety hazard. Use with caution.
Exterior A/C - Heat pump #1
Unit #1 N/ALocation:Brand:CarrierModel #: Serial #:Approximate Age: 5-10+
Condition X Satisfactory Marginal Poor Cabinet/housing rusted
Energy source X Electric Gas Other:
Unit type X Air cooled Water cooled Geothermal Heat pump
Outside Disconnect X Yes No Maximum fuse/breaker rating (amps): Fuses/Breakers installed (amps):Improperly sized fuses/breakers
Level X Yes No Recommend re-level unit
Condenser Fins X Damaged Need cleaning Damaged base/pad Damaged Refrigerant Line Satisfactory
Insulation Yes No X Replace
Improper Clearance (air flow) Yes X No
Comments Damaged/Missing insulation recommend replacing insulation
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 16
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
ExteriorExterior A/C - Heat pump #2
Unit #2 N/ALocation:Brand:LennoxModel #: 153f5677Serial #: 35r43edApprox. Age: 5-10+
Energy source X Electric Gas Other:
Unit type Air cooled Water cooled Geothermal X Heat pump
Outside Disconnect X Yes No Maximum fuse/breaker rating (amps): Fuses/Breakers installed (amps):Improperly sized fuses/breakers
Level X Yes No Recommend re-level unit
Condenser Fins Damaged X Need cleaning Damaged base/pad Damaged Refrigerant Line Satisfactory
Insulation X Yes No Replace
Condition X Satisfactory Marginal Poor Cabinet/housing rusted
Improper Clearance (air flow) Yes X No
Comments Outside condenser unit coils dirty recommend cleaning Heat pump was in normal working order.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 17
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Garage/CarportType
None
Type Attached Detached 1-Car X 2-Car 3-Car 4-Car Carport
Comments 2-car
Photos
Automatic Opener
None N/A
Operation X Operable Inoperable
Comments Emergency release rope missing, potential safety hazard. Recommend adding disconnect rope
Safety Reverse
None N/A
Operation X Operable Not Operable Need(s) adjusting Safety hazardX Photo eyes and pressure reverse tested
Comments Electric eyes too high above ground, potential safety hazard. Recommend 6" from floor
Roofing
Material X Same as houseType:Approx. age: Approx. layers:
Comments
Gutters/Eavestrough
Condition X Satisfactory Marginal Poor Same as house
Comments
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 18
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Garage/CarportSiding
N/A
Material X Same as house Wood Metal Vinyl Stucco Masonry Slate Fiberboard
Condition X Satisfactory Marginal Poor Recommend repair/replace Recommend painting
Comments Siding was in need of normal maintenance repairs.
Trim
N/A
Material X Same as house Wood Aluminum Vinyl
Condition Satisfactory X Marginal Poor Recommend repair/replace Recommend painting
Comments Trim was in need of normal maintenance repairs.
Floor
Material X Concrete Gravel Asphalt Dirt Other:
Condition X Satisfactory Typical cracks Large settling cracks Recommend evaluation/repairSafety hazard
Source of Ignition within 18" of the floor X N/A Yes No
Comments Garage floor has typical cracks.
Sill Plates
None X Not Visible
Type Floor level Elevated
Condition Rotted/Damaged Recommend repair
Comments Sill plates not visible.
Overhead Door(s)
N/A
Material Wood X Fiberglass Masonite Metal Recommend repair
Condition Satisfactory Marginal Poor Hardware loose Safety Cable RecommendedX Weatherstripping missing/damaged Loose/missing
Recommend Priming/Painting Inside & Edges X Yes No
Comments Garage door opener safety reverse not working properly recommend repair
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 19
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Garage/Carport
Exterior Service Door
None
Condition X Satisfactory Marginal Poor Damaged/Rusted
Comments Service door opens into a bedroom - SAFETY HAZARD.
Electrical Receptacles
X Yes No Not Visible Operable: Yes No
Reverse polarity X Yes No
Open ground Yes X No X Safety Hazard
GFCI Present Yes X No Operable: Yes No Handyman/extension cord wiringX Recommend GFCI Receptacles
Comments Open ground is a potential safety hazard. Recommend repair by a qualified electrical contractor
Fire Separation Walls & Ceiling
X N/A Present Missing Recommend repair
Condition X Satisfactory Recommend repair Holes walls/ceiling Safety hazard(s)
Moisture Stains Present X Yes No
Typical Cracks X Yes No
Fire door Not verifiable X Not a fire door Needs repair Satisfactory
Self closure X N/A Satisfactory Inoperative Missing
Comments Firewall protection recommended on access to attic.
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 20
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
KitchenCountertops
Condition X Satisfactory Marginal Recommend repair/caulking
Comments
Photos
Cabinets
Condition X Satisfactory Marginal Recommend repair/adjustment
Comments Cabinets have normal wear.
Plumbing
Faucet Leaks X Yes No
Pipes leak/corroded X Yes No
Sink/Faucet X Satisfactory Corroded Chipped Cracked Recommend repair
Functional drainage X Satisfactory Marginal Poor
Functional flow X Satisfactory Marginal Poor
Comments Water flow was normal with several fixtures operated at the same time. Drains show signs of leakage recommend repair
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 21
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Kitchen
Walls & Ceiling
Condition X Satisfactory Marginal Poor Typical cracks Moisture stains
Comments
Heating/Cooling Source
X Yes No
Comments
Floor
Condition Satisfactory X Marginal Poor Sloping Squeaks
Comments
Appliances
Disposal N/A Not tested Operable: X Yes No
Oven N/A Not tested Operable: X Yes No
Range N/A Not tested Operable: X Yes No
Dishwasher N/A Not tested Operable: X Yes No
Trash Compactor N/A Not tested Operable: X Yes No
Exhaust fan N/A Not tested Operable: X Yes No
Refrigerator N/A Not tested Operable: X Yes No
Microwave N/A Not tested Operable: X Yes No
Other Operable: X Yes No
Dishwasher airgap Yes X No
Dishwasher drain line looped X Yes No
Receptacles present X Yes No Operable: X Yes No
GFCI Yes X No Operable: Yes No Recommend GFCI Receptacles: X Yes NoX Potential Safety Hazard(s)
Open ground/Reverse polarity: Yes X No Potential Safety Hazard
Comments
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 22
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Kitchen
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 23
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Laundry RoomLaundry
Laundry sink X N/A
Faucet leaks Yes X No
Pipes leak Yes X No Not Visible
Cross connections Yes X No Potential Safety Hazard
Heat source present X Yes No
Room vented X Yes No
Dryer vented N/A X Wall Ceiling Floor Not vented Plastic dryer vent not recommendedNot vented to exterior Recommend repair Safety hazard
Electrical Open ground/reverse polarity: X Yes No X Safety hazard
GFCI present X Yes No Operable: X Yes No Recommend GFCI Receptacles
Appliances X Washer X Dryer X Water heater Furnace/Boiler
Washer hook-up lines/valves Satisfactory Leaking X Corroded Not Visible
Gas shut-off valve N/A X Yes No Cap Needed Safety hazard Not Visible
Comments Cross connection present - grey water could be forced back into the water system - Safety Concern. Recommend repair
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 24
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Bathroom (1)Bath
Location First floor bath
Sinks Faucet leaks: Yes X No Pipes leak: Yes X No
Tubs N/A Faucet leaks: Yes X No Pipes leak: Yes X No Not Visible
Showers N/A Faucet leaks: X Yes No Pipes leak: Yes X No Not Visible
Toilet Bowl loose: X Yes No Operable: X Yes No Cracked bowl Toilet leaks
Whirlpool Yes X No Operable: Yes No Not tested No access door GFCI: Yes NoGFCI Recommended
Shower/Tub area Ceramic/Plastic X Fiberglass Masonite Other: Condition: X Satisfactory MarginalPoor Rotted floors Caulk/Grouting needed: Yes X No
Where:N/A
Drainage X Satisfactory Marginal Poor
Water flow X Satisfactory Marginal Poor
Moisture stains present X Yes No Walls Ceilings Cabinetry
Doors Satisfactory X Marginal Poor
Window None X Satisfactory Marginal Poor
Receptacles present X Yes No Operable: X Yes No
GFCI X Yes No Operable: X Yes No Recommend GFCI
Open ground/Reverse polarity Yes X No Potential Safety Hazard
Heat source present X Yes No
Exhaust fan X Yes No Operable: X Yes No X Noisy
Comments Pipes are leaking - recommend repair and/or replacement Caulk or grouting recommended in tub area.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 25
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Bathroom (1)
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 26
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Bathroom (2)Bath
Location Second floor half bath
Sinks Faucet leaks: X Yes No Pipes leak: X Yes No
Tubs N/A Faucet leaks: Yes X No Pipes leak: Yes X No Not Visible
Showers N/A Faucet leaks: X Yes No Pipes leak: Yes X No Not Visible
Toilet Bowl loose: Yes X No Operable: X Yes No Cracked bowl Toilet leaks
Whirlpool X Yes No Operable: X Yes No Not tested No access door GFCI: Yes X NoX GFCI Recommended
Shower/Tub area X Ceramic/Plastic Fiberglass Masonite Other: Condition: Satisfactory X MarginalPoor Rotted floors Caulk/Grouting needed: Yes X No
Where:N/A
Drainage X Satisfactory Marginal Poor
Water flow Satisfactory X Marginal Poor
Moisture stains present X Yes No Walls X Ceilings Cabinetry
Doors X Satisfactory Marginal Poor
Window None X Satisfactory Marginal Poor
Receptacles present X Yes No Operable: X Yes No
GFCI Yes X No Operable: Yes No X Recommend GFCI
Open ground/Reverse polarity X Yes No X Potential Safety Hazard
Heat source present Yes X No
Exhaust fan Yes X No Operable: Yes No Noisy
Comments Ground-fault outlet was not operating properly, won't trip recommend replacing
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 27
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Bathroom (2)
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 28
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
InteriorFireplace
None
Location(s) Living room
Type Gas X Wood Solid fuel burning stove Electric Ventless
Material X Masonry Metal (pre-fabricated) Metal insert Cast Iron
Miscellaneous X Blower built-in Operable: X Yes No Damper operable: X Yes NoOpen joints or cracks in firebrick/panels should be sealed Fireplace doors need repair
Damper modified for gas operation X N/A Yes No Damper missing
Hearth extension adequate X Yes No
Mantel N/A Secure X Loose Recommend repair/replace
Physical condition X Satisfactory Marginal Poor Recommend having flue cleaned and re-examinedNot evaluated
Comments Hearth/mantle is loose - Recommend securing
Photos
Needs Sealed Call Me
Stairs/Steps/Balconies
None
Condition Satisfactory X Marginal Poor Loose/Missing
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 29
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
InteriorStairs/Steps/Balconies cont.
Handrail X Satisfactory Marginal Poor Safety hazard Hand Rail/Railing/Balusters recommended
Risers/Treads X Satisfactory Marginal Poor Risers/Treads uneven Trip hazard
Comments Handrail loose, potential safety hazard. Recommend securing/repair
Smoke/Carbon Monoxide detectors
Smoke Detector X Present Not Present Operable: X Yes No Not tested Recommend additionalSafety Hazard
CO Detector Present X Not Present Operable: Yes No Not tested Recommend additionalX Safety Hazard
Comments Recommend changing smoke detectors batteries every 6 months
Attic/Structure/Framing/Insulation
N/A
Access Stairs X Pulldown Scuttlehole/Hatch No Access Other: Access limited by:
Inspected from Access panel X In the attic Other
Location Hallway Bedroom Closet X Garage Other
Flooring Complete X Partial None
Insulation X Fiberglass Batts Loose Cellulose Foam Other Vermiculite Rock woolDepth: 11 Damaged Displaced Missing Compressed Recommend additional insulation
Installed in Rafters/Trusses Walls X Between ceiling joists Underside of roof deck Not Visible
Vapor barriers Kraft/foil faced Plastic sheeting X Not Visible Improperly installed
Ventilation X Ventilation appears adequate Recommend additional ventilation Recommend baffles at eaves
Fans exhausted to Attic: Yes X No Recommend repair Outside: X Yes No Not Visible
HVAC Duct N/A X Satisfactory Damaged Split Disconnected Leaking Repair/ReplaceRecommend Insulation
Chimney chase N/A X Satisfactory Needs repair Not Visible
Structural problems observed Yes X No Recommend repair Recommend structural engineer
Roof structure Rafters X Trusses Wood Metal Collar ties Purlins Knee wall Not Visible Other:
Ceiling joists X Wood Metal Not Visible
Sheathing Plywood X OSB Planking Rotted Stained Delaminated
Evidence of condensation Yes X No
Evidence of moisture Yes X No
Evidence of leaking Yes X No
Firewall between units N/A X Yes No Needs repair/sealing
Electrical No apparent defects X Open junction box(es) Handyman wiringKnob and tube covered with insulation Safety Hazard
Comments Recommend proper weatherstripping be installed around attic access Insulation was sufficient for homes in this area. Recommend junction boxes be covered-SAFETY HAZARD.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 30
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Interior
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 31
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Crawl SpaceCrawl space
N/A
Type X Full crawlspace Combination basement/crawl space/slab
Conditioned (heated/cooled) Yes X No
Comments
Photos
Kevin
Access
Location X Exterior Interior hatch/door Via basement No access
Inspected from Access panel X In the crawl space
Comments
Foundation walls
Condition X Satisfactory Marginal Have Evaluated Monitor Cracks Movement
Material X Concrete block Poured concrete Stone ICF Wood Brick
Comments
Floor
Material Concrete Gravel X Dirt Other:
Condition Typical cracks Not Visible X Vapor barrier present
Comments
Seismic bolts
X N/A None visible
Condition Appear satisfactory Recommed evaluation
Comments
Drainage
Sump pump Yes X No Operable: Yes No Pump not tested
Standing water Yes X No Not Visible
Evidence of moisture damage Yes X No
Comments
Ventilation
N/A
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 32
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Crawl SpaceVentilation cont.
Location X Wall vents Power vents None apparent
Condition X Additional ventilation recommended Evidence of moisture damage
Comments Ventilation is inadequate - recommend adding more vents.
Girders/Beams/Columns
Material Steel X Wood Masonry
Condition X Satisfactory Marginal Poor Not Visible Sagging/Altered
Comments Girders are broken - recommend qualified contractor repair and/or replace as necessary.
Joists
Material Wood Steel Truss Not Visible 2x8 2x10 X 2x12 Engineered I-TypeSagging/Altered joists
Condition X Satisfactory Marginal Poor
Comments
Subfloor
Not Visible
Condition X Indication of moisture stains/rotting
Comments
Insulation
None
Type X Fiberglass Cellulose Rockwool Foam Not VisibleFiberglass
Location Walls X Between floor joists Other:
Comments Insulation was damaged / missing , recommend repair
Vapor barrier
Present X Yes No Not Visible Improperly installed
Material X Kraft/foil faced Plastic Not Visible Other:
Condition X Satisfactory Marginal Poor
Comments
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 33
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
PlumbingWater service
Main shut-off location Outside at curbside
Water entry piping Not Visible X Copper/Galv. PVC Plastic CPVC Plastic Polybutylene PlasticPEX Plastic Lead Polyethylene
Lead other than solder joints Yes X No Unknown Service entry
Visible water distribution piping Copper Galvanized PVC Plastic CPVC Plastic Polybutylene PlasticX PEX Plastic Other:
Condition X Satisfactory Marginal Poor
Flow X Satisfactory Marginal Poor Water pressure over 80 psi Recommend plumber evaluateRecommend pressure regulator
Pipes Supply/Drain Corroded X Leaking Valves broken/missing Dissimilar metal Cross connection: YesNo Safety Hazard X Recommend repair Recommend a dielectric union Satisfactory
Drain/Waste/Vent pipe X Copper Cast iron Galvanized PVC ABS Brass
Condition X Satisfactory Marginal Poor
Support/Insulation X N/AType:
Traps proper P-Type X Yes No P-traps recommended
Drainage X Satisfactory Marginal Poor
Interior fuel storage system X N/A Yes No Leaking: Yes No
Fuel line N/A Copper Brass Black iron Stainless steel CSST Not Visible GalvanizedX Recommend CSST be properly bonded
Condition N/A X Satisfactory Marginal Poor Recommend plumber evaluate
Comments
Photos
Main fuel shut-off location
N/A
Location On the front exterior wall
Comments Gas meter on exterior of home.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 34
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Plumbing
Well pump
N/A
Type Submersible In basement X Well house Well pit Shared well
Pressure gauge operable X Yes No Well pressure: 25 psi Not Visible
Comments
Sanitary/Grinder pump
N/A Operable: X Yes No
Sealed Crock Sealed crock: Yes X No
Check Valve Check valve: X Yes No
Shut-off Valve Shut-off valve: X Yes No
Vented X Yes No
Comments
Water heater #1
N/A
General Brand Name: RheemSerial #: 5675432Capacity:50Approx. age: 5-10+
Type Gas X Electric Oil LP Other:
Combustion air venting present Yes No X N/A
Seismic restraints needed Yes X No N/A
Relief valve X Yes No Extension proper: Yes X No Missing X Recommend repairImproper material
Vent pipe N/A X Satisfactory Pitch proper Improper Rusted Recommend repair
Condition Satisfactory X Marginal Poor
Comments Temperature-Pressure relief valve extension should be 4"-6" off of the floor - this is a Safety Concern.
Water heater #2
N/A
General Brand Name: A.O. Smith Serial #: 456789Capacity:40Approx. age: Unknown
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 35
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
PlumbingWater heater #2 cont.
General cont.Older20-25+
Type X Gas Electric Oil LP Other:
Combustion air venting present X Yes No N/A
Seismic restraints needed Yes No X N/A
Relief valve X Yes No Extension proper: X Yes No Missing Recommend repairImproper material
Vent pipe N/A Satisfactory Pitch proper Improper X Rusted Recommend repair
Condition Satisfactory X Marginal Poor
Comments Excessive rust present on vent pipe - recommend repairing and/or replacing
Water softener
None
Loop installed X Yes No
Plumbing hooked up X Yes No
Plumbing leaking Yes X No
Comments
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 36
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Heating SystemHeating system
Unit #1 Brand name: LennoxApprox. age: 1-5+
Unknown Model #: 123R457 Serial #: 5678765 Satisfactory X Marginal PoorRecommended HVAC technician examine
Unit #2 NoneBrand name: RheemApprox. age: 1-5+
UnknownModel #: Serial #: 4521D34 Satisfactory Marginal Poor Recommended HVAC technician examine
Energy source X Gas LP Oil Electric Solid fuel
Warm air system Belt drive Direct drive Gravity X Central system Floor/wall furnace
Heat exchanger N/A Sealed Not Visible Visual w/mirror Flame distortion RustedX Carbon/soot buildup
Carbon monoxide N/A X Detected at plenum Detected at register Not testedTester:Monoxer II
Combustion air venting present N/A X Yes No
Controls Disconnect: X Yes No X Normal operating and safety controls observed Gas shut off valve:X Yes No
Distribution X Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrapSafety Hazard
Flue piping N/A Satisfactory Rusted X Improper slope X Safety hazard Recommend repair/replace
Filter X Standard Electrostatic Satisfactory X Needs cleaning/replacement MissingElectronic (not tested)
When turned on by thermostat X Fired Did not fire Proper operation: X Yes No Not tested
Heat pump X N/A Supplemental electric Supplemental gas
Sub-slab ducts X N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No
System not operated due to X N/A Exterior temperature Other:
Comments Furnace was producing high levels of carbon monoxide in flue, recommend a qualified HVAC technican examine
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 37
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Heating SystemBoiler system
X N/A
General Brand name: Approx. age: Model #: Serial #:
Energy source Gas LP Oil Electric Solid fuel
Distribution Hot water Baseboard Steam Radiator Radiant floor
Circulator Pump Gravity Multiple zones
Controls Temp/pressure gauge exist: Yes No Operable: Yes No
Oil fired units Disconnect: Yes No
Combustion air venting present Yes No N/A
Relief valve Yes No Missing Extension proper: Yes No Recommend repair/replace
Operated When turned on by thermostat: Fired Did not fire
Operation Satisfactory: Yes No Recommend HVAC technician examine before closing
Comments
Other systems
X N/A
Type Electric baseboard Radiant ceiling cable Gas space heater Solid fuel burning stove
Proper operation Yes No
System condition Satisfactory Marginal Poor Recommend HVAC Technician Examine
Comments
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 38
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Electric/Cooling SystemMain panel
LocationGarage
Condition X Satisfactory Poor
Adequate Clearance to Panel X Yes No
Amperage/Voltage Unknown 60a 100a 150a X 200a 400a 120v/240v
Breakers/Fuses X Breakers Fuses
Appears grounded X Yes No Not Visible
GFCI breaker X Yes No Operable: X Yes No
AFCI breaker Yes X No Operable: Yes No Not Tested
Main wire X Copper Aluminum Not Visible Double tapping of the main wire Condition: X SatisfactoryMarginal Poor
Branch wire X Copper Aluminum Solid Branch Aluminum Wiring Not Visible Safety Hazard
Branch wire condition X Satisfactory Poor Recommend electrician evaluate/repair Romex BX cableConduit Knob/Tube Double tapping Wires undersized/oversized breaker/fusePanel not accessible Not evaluated
Reason:
Comments Panel size appeared to be compatible to service size.
Photos
Sub panel(s)
None apparent
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 39
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Electric/Cooling SystemSub panel(s) cont.
Location(s) Location 1: GarageLocation 2: Hot Tub Location 3:
Evaluation Panel not accessible Not evaluatedReason:X Recommend separating/isolating neutrals Recommend electrician repair/evaluate box
Branch wire X Copper Aluminum Safety hazard Neutral/ground separated: Yes X No Neutral isolated:Yes X No
Condition Satisfactory Marginal X Poor
Comments The ground and neutral wires are not separated - recommend licensed electrician separate
Photos
Evaporator Coil Section Unit #1
N/A
General X Central system Wall unitLocation:Age:5-10+
Evaporator coil Satisfactory Not Visible X Needs cleaning Damaged
Refrigerant lines Leak/Oil present Damage X Insulation missing Satisfactory
Condensate line/drain X To exterior To pump Floor drain Other:
Secondary condensate line/drain Present: Yes X No Needed: Yes X No Primary pan appears cloggedRecommend technician evaluate
Operation Differential: 71
Condition X Satisfactory Marginal Poor Recommend HVAC technician examine/clean/serviceNot operated due to exterior temperature
Comments A/C unit operated properly.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 40
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Electric/Cooling System
Evaporator Coil Section Unit #2
N/A
General X Central system Wall unitLocation:Age:20-25+
Evaporator coil Satisfactory Not Visible X Needs cleaning Damaged
Refrigerant lines Leak/Oil present X Damage Insulation missing SatisfactoryRecommend/Replace damaged/missing insulation
Condensate line/drain To exterior To pump X Floor drain Other:
Secondary condensate line/drain Present: Yes X No Needed: Yes No Primary pan appears cloggedRecommend technician evaluate
Operation Differential: 69
Condition X Satisfactory Marginal Poor Recommend HVAC technician examine/clean/serviceNot operated due to exterior temperature
Comments A/C unit operated properly.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 41
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Electric/Cooling System
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 42
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Living RoomLiving Room
Location First floor SW
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan None X Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors None Satisfactory Marginal Poor Cracked glass X Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments Ceiling fan is wobbling, recommend repair.
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
1234 Street , Anywhere , OK 73075 Page 43
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC
Dining RoomDining Room
Location North
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan None X Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: X Yes No X Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None Satisfactory X Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments Evidence of leaking insulated glass. Recommend repair/replacement of window
Photos
This confidential report is prepared exclusively for John Doe©2019 Green Light Properties, LLC