Home Inspection Report
1538 W Greenleaf, Plainfield, IL 60586
Inspection Date:Saturday June 27, 2015
Prepared For:John Doe
Prepared By:Home Anatomy Inspection Services LLC
14855 Van Dyke Rd #540Plainfield, IL 60544
Report Number:20150606
Inspector:Bruce Hedlund
1538 W Greenleaf, Plainfield, IL 60586 Page 2
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Receipt/InvoiceHome Anatomy Inspection Services LLC14855 Van Dyke Rd #540Plainfield, IL 60544815-556-9516
Property Address1538 W GreenleafPlainfield, IL 60586
Date: Jun 27, 2015 Inspection Number: 20150606
Inspected By: Bruce Hedlund Payment Method: Not Paid
Client: John Doe
Inspection FeeHome Inspection $0.00
Total $0.00
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 3
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Report SummaryItems Not Operating
None apparent
Major ConcernsNone apparent
Potential Safety HazardsRecommending grounding of sub panel in garage by qualified electrician. No physical conduit from house or ground rod tied to garage. Safety hazard. Recommend no ignition source within 18" of floor in a garage unless it is of a Flammable Vapor Ignition Resistant (FVIR) DESIGN.
Deferred Cost ItemsFurnace that is 19+ years old. AC that is 24+ years old. Driveway has severe flaking. Recommend repair. Cast iron DWV pipe is 50+ years old and nearing end of life. Starting to flake.
Improvement ItemsNone apparent.
Items To MonitorCast Iron DWV Pipe.
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 4
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Report OverviewHouse in Perspective
Average Quality/Well Maintained
Scope of InspectionAll components designated for inspection in the InterNACHI Standards of Practice are inspected, except as may be noted in the "Limitations of Inspection" sections within this report. It is the goal of the inspection to put a home buyer in a better position to make a buying decision. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. The inspection should not be considered a guarantee or warranty of any kind.Please refer to the pre-inspection contract for a full explanation of the scope of the inspection. SATISFACTORY - Indicates the component is fuctionally consistent with its original purpose, but may show signs of normal wear and tear and deterioration. MARGINAL - Indicates the component will probably require repair or replacement anytime within five years. POOR - Indicates the component will need repair or replacement now, or in the very near future. MAJOR CONCERNS - A system or component that is considered significantly deficient or is unsafe. SAFETY HAZARD - Denotes a condition that is unsafe and in need of prompt attention.
Main Entrance FacesNorth
State of OccupancyOccupied Fully furnished
Weather ConditionsSunny
Recent RainNo
Ground CoverDry
Approximate Age
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 5
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Report Overview50
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 6
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
GarageType
None
Type Attached X Detached 1-Car 2-Car X 2-1/2-Car 3-Car 4-Car Carport
Comments Garage is Insulated
Photos
Automatic Opener
None N/A
Operation X Operable Inoperable
Comments
Safety Reverse
None N/A
Operation X Operable Not Operable Need(s) adjusting Safety hazardX Photo eyes and pressure reverse tested
Comments
Roofing
Material X Same as houseType: Approx. age: 5 Approx. layers: 2
Comments
Gutters/Eavestrough
Condition X Satisfactory Marginal Poor Same as house
Comments
Siding
N/A
Material Same as house X Wood Metal Vinyl Stucco Masonry Slate Fiberboard
Condition X Satisfactory Marginal Poor Recommend repair/replace Recommend painting
Comments
Trim
N/A
Material X Same as house X Wood X Aluminum Vinyl
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 7
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
GarageTrim cont.
Condition X Satisfactory Marginal Poor Recommend repair/replace Recommend painting
Comments
Floor
Material X Concrete Gravel Asphalt Dirt Other
Condition Satisfactory Typical cracks X Large settling cracks Recommend evaluation/repairSafety hazard
Source of Ignition within 18" of the floor X N/A Yes No
Comments
Sill Plates
None X Not Visible
Type X Floor level Elevated
Condition Rotted/Damaged Recommend repair
Comments Sill plates not visible.
Overhead Door(s)
N/A
Material X Wood Fiberglass Masonite Metal Recommend repair
Condition X Satisfactory Marginal Poor Hardware loose Safety Cable RecommendedWeatherstripping missing/damaged Loose/missing
Recommend Priming/Painting Inside & Edges Yes X No
Comments Garage door and opener were in normal working order.
Exterior Service Door
None
Condition X Satisfactory Marginal Poor Damaged/Rusted
Comments
Electrical Receptacles
X Yes No Not Visible Operable: X Yes No
Reverse polarity Yes X No
Open ground X Yes No Safety Hazard
GFCI Present Yes X No Operable: Yes No Handyman/extension cord wiringX Recommend GFCI Receptacles
Comments
Fire Separation Walls & Ceiling
X N/A Present Missing Recommend repair
Condition Satisfactory Recommend repair Holes walls/ceiling Safety hazard(s)
Moisture Stains Present Yes No
Typical Cracks Yes No
Fire door Not verifiable Not a fire door Needs repair Satisfactory
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 8
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
GarageFire Separation Walls & Ceiling cont.
Self closure N/A Satisfactory Inoperative Missing
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 9
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
GroundsService Walks
None Not Visible
Material X Concrete Flagstone Gravel Brick Other
Condition X Satisfactory Marginal Poor Trip hazard X Typical cracks Pitched towards homeSettling cracks Public sidewalk needs repair
Comments
Driveway/Parking
None Not Visible
Material Concrete X Asphalt Gravel/Dirt Brick Other
Condition Satisfactory X Marginal Poor Settling Cracks Typical cracks Pitched towards homeTrip hazard X Fill cracks and seal
Comments Driveway has severe flaking. Recommend repair. Down to gravel in places.
Porch
X None Not Visible
Condition Satisfactory Marginal Poor Railing/Balusters recommended
Support Pier Concrete Wood Other
Floor Satisfactory Marginal Poor Safety Hazard
Comments
Stoops/Steps
None
Material X Concrete Wood Other Railing/Balusters recommended
Condition X Satisfactory Marginal Poor Safety Hazard Uneven risers Rotted/DamagedCracked Settled
Comments
Patio
None
Material X Concrete Flagstone Kool-Deck Brick Other
Condition X Satisfactory Marginal Poor X Settling cracks Trip hazardPitched towards home (see remarks) Drainage provided Typical cracks
Comments
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 10
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Grounds
Deck/Balcony
X None Not Visible
Material Wood Metal Composite Railing/Balusters recommended
Condition Satisfactory Marginal Poor Wood in contact with soil
Finish Treated Painted/Stained Other Safety Hazard Improper attachment to houseRailing loose Not Applicable
Comments
Deck/Patio/Porch Covers
X None
Condition Satisfactory Marginal Poor Posts/Supports need Repair Earth to wood contactMoisture/Insect damage
Recommend Metal Straps/Bolts/Nails/Flashing Improper attachment to house None
Comments
Fence/Wall
Not evaluated None
Type Brick Block X Wood Metal Chain Link Rusted X Vinyl
Condition Satisfactory X Marginal Poor Typical cracks Loose Blocks/Caps
Gate N/A X Satisfactory Marginal Poor Planks missing/damaged Operable: X Yes No
Comments Wood fence damaged, recommend repair.
Landscaping affecting foundation
X N/A
Negative Grade East West North South X Satisfactory Recommend additional backfillRecommend window wells/covers Trim back trees/shrubberiesWood in contact with/improper clearance to soil
Comments
Retaining wall
X None
Material Brick Concrete Concrete block Other Railroad ties Timbers
Condition Satisfactory Marginal Poor Safety Hazard Leaning/cracked/bowedDrainage holes recommended
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 11
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
GroundsHose bibs
N/A
Condition X Satisfactory Marginal Poor No anti-siphon valve Recommend Anti-siphon valve
Operable X Yes No Not Tested Not On
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 12
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
RoofGeneral
Visibility None X All Partial Limited By
Inspected From X Roof Ladder at eaves Ground With Binoculars
Style of Roof
Type X Gable Hip Mansard Shed Flat Other
Pitch Low X Medium Steep Flat
Roof #1 Type: Asphalt Layers: 1 Age: 4 Location: House
Comments
Ventilation System
None N/A
Type X Soffit Ridge X Gable X Roof Turbine X Powered Other
Comments
Flashing
Material Not Visible X Galv/Alum Asphalt Copper Foam Rubber Lead Other
Condition Not Visible X Satisfactory Marginal Poor Rusted MissingSeparated from chimney/roof Recommend Sealing Other
Comments
Valleys
N/A
Material X Not Visible Galv/Alum Asphalt Lead Copper Other
Condition Not Visible X Satisfactory Marginal Poor Holes Rusted Recommend Sealing
Comments
Condition of Roof Coverings
Roof #1 X Satisfactory Marginal Poor Curling Cracking Ponding Burn SpotsBroken/Loose Tiles/Shingles Nail popping Granules missing Alligatoring BlisteringMissing Tabs/Shingles/Tiles Moss buildup Exposed felt CuppingIncomplete/Improper Nailing Recommend roofer evaluate Evidence of Leakage
Comments
Skylights
X N/A Not Visible
Condition Cracked/Broken Satisfactory Marginal Poor
Comments
Plumbing Vents
Not Visible Not Present
Condition X Satisfactory Marginal Poor
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 13
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
ExteriorChimney(s)
None
Location(s) Middle of Roof
Viewed From X Roof Ladder at eaves Ground (Inspection Limited) With Binoculars
Rain Cap/Spark Arrestor X Yes No Recommended
Chase Brick Stone X Metal Blocks Framed
Evidence of Holes in metal Cracked chimney cap Loose mortar joints Flaking Loose brick RustX No apparent defects
Flue Tile X Metal Unlined Not Visible
Evidence of Scaling Cracks Creosote Not evaluated Have flue(s) cleaned and re-evaluatedRecommend Cricket/Saddle/Flashing X No apparent defects
Condition X Satisfactory Marginal Poor Recommend Repair
Comments
Gutters/Scuppers/Eavestrough
None
Condition X Satisfactory Marginal Poor Rusting Downspouts needed Recommend repair/replaceNeeds to be cleaned
Material Copper Vinyl/Plastic X Galvanized/Aluminum Other
Leaking Corners Joints Hole in main run X No apparent leaks
Attachment Loose Missing spikes Improperly sloped X Satisfactory
Extension needed North South East West X N/A
Comments
Siding
Material Stone Slate Block/Brick Fiberboard Fiber-cement Stucco EIFS* Not InspectedAsphalt X Wood Metal/Vinyl Other Typical cracks Peeling paint MonitorWood rot Loose/Missing/Holes
Condition X Satisfactory Marginal Poor Recommend repair/painting
Comments
Trim
Material X Wood Fiberboard X Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other
Condition X Satisfactory Marginal Poor
Comments
Soffit
None
Material Wood Fiberboard X Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other
Condition X Satisfactory Marginal Poor
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 14
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
ExteriorFascia
None
Material Wood Fiberboard X Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other
Condition X Satisfactory Marginal Poor
Comments
Flashing
None
Material Wood Fiberboard X Aluminum/Steel Vinyl Stucco Recommend repair/paintingDamaged wood Other
Condition X Satisfactory Marginal Poor
Comments
Caulking
None
Condition X Satisfactory Marginal PoorRecommend around windows/doors/masonry ledges/corners/utility penetrations
Comments
Windows/Screens
Condition X Satisfactory Marginal Poor Wood rot Recommend repair/paintingRecommend repair/replace damaged screens Failed/fogged insulated glass
Material X Wood Metal X Vinyl Aluminum/Vinyl clad
Screens Torn Bent Not installed X Satisfactory
Comments
Storms Windows
X None Not installed
Condition Satisfactory Broken/cracked Wood rot Recommend repair/painting
Material Wood Clad comb. Wood/Metal comb. Metal
Putty Satisfactory Needed N/A
Comments
Slab-On-Grade/Foundation
Foundation Wall Concrete block X Poured concrete Post-Tensioned concrete Not Visible Other
Condition X Satisfactory Marginal Monitor Have Evaluated Not Evaluated
Concrete Slab X N/A Not Visible Satisfactory Marginal Monitor Have Evaluated
Comments
Service Entry
Location Underground X Overhead
Condition X Satisfactory Marginal Poor Weather head/mast needs repair Overhead wires too low
Exterior receptacles X Yes No Operable: X Yes No Condition: X Satisfactory Marginal Poor
GFCI present Yes X No Operable: Yes No Safety Hazard Reverse polarity Open ground(s)
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 15
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
ExteriorService Entry cont.
GFCI present cont. X Recommend GFCI Receptacles
Comments
Building(s) Exterior Wall Construction
Type X Not Visible Framed Masonry Other
Condition X Not Visible Satisfactory Marginal Poor
Comments Building structure not visible due to siding, not evaluated.
Exterior Doors
Main Entrance N/A Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Patio X N/A Weatherstripping: Satisfactory Marginal Poor Missing ReplaceDoor condition: Satisfactory Marginal Poor
Rear door N/A Weatherstripping: X Satisfactory Marginal Poor Missing ReplaceDoor condition: X Satisfactory Marginal Poor
Other door X N/A Weatherstripping: Satisfactory Marginal Poor Missing ReplaceDoor condition: Satisfactory Marginal Poor
Comments
Exterior A/C - Heat pump #1
Unit #1 N/ALocation: Outside SE corner Brand: York
Model #: B345CF7800 Serial #:Approximate Age: 20-25+
Condition Satisfactory X Marginal Poor Cabinet/housing rusted
Energy source X Electric Gas Other
Unit type X Air cooled Water cooled Geothermal Heat pump
Outside Disconnect X Yes No Maximum fuse/breaker rating (amps): 30 Fuses/Breakers installed (amps): 30Improperly sized fuses/breakers
Level X Yes No Recommend re-level unit
Condenser Fins Damaged Need cleaning Damaged base/pad Damaged Refrigerant Line X Satisfactory
Insulation on Low Pressure Line X Yes No Replace
Improper Clearance (air flow) Yes X No
Comments
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 16
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Exterior
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 17
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
InteriorStairs/Steps/Balconies
None
Condition X Satisfactory Marginal Poor Loose/Missing
Handrail X Satisfactory Marginal Poor Safety hazard Hand Rail/Railing/Balusters recommended
Risers/Treads X Satisfactory Marginal Poor Risers/Treads uneven Trip hazard
Comments
Smoke/Carbon Monoxide detectors
Smoke Detector X Present Not Present X Operable Safety Hazard
CO Detector X Present Not Present X Operable Safety Hazard X Recommend Additional DetectorsWhere: CO in Basement
Comments Age of alarms not verified. Smoke and Carbon Monoxide alarms have a limited service life. Recommend replacing smoke alarms every 10 years and carbon monoxide alarms every 5 to 7 years. Testing of alarms only test the alarm circuits, not the sensors. Smoke and carbon monoxide alarms should be installed according to manufacturers instructions, which was not verified during inspection.
Attic/Structure/Framing/Insulation
N/A
Attic Access X Stairs X Pulldown Scuttlehole/Hatch No Access Other
Inspected from Access panel X In the attic Other
Access Location X Hallway Bedroom Closet Garage Other
Access limited by Not limited
Flooring Complete Partial X None
Insulation X Fiberglass X Batts Loose Cellulose Foam Other Vermiculite Rock woolDepth: 6" Damaged Displaced Missing Compressed X Recommend additional insulation
Installed in Rafters/Trusses Walls X Between ceiling joists Underside of roof deck Not Visible
Vapor barriers Kraft/foil faced Plastic sheeting X Not Visible Improperly installed
Ventilation X Ventilation appears adequate Recommend additional ventilation Recommend baffles at eaves
Fans exhausted to X Attic Outside Not Visible
HVAC Duct N/A X Satisfactory Damaged Split Disconnected Leaking Repair/ReplaceRecommend Insulation
Chimney chase X N/A Satisfactory Needs repair Not Visible
Structural problems observed Yes X No Recommend repair Recommend structural engineer
Roof structure X Rafters Trusses Wood Metal Collar ties Purlins Knee wall Not VisibleOther
Ceiling joists X Wood Metal Not Visible
Sheathing Plywood OSB X Planking Rotted Stained Delaminated
Evidence of condensation Yes X No
Evidence of moisture Yes X No
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 18
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
InteriorAttic/Structure/Framing/Insulation cont.
Evidence of leaking Yes X No
Firewall between units X N/A Yes No Needs repair/sealing
Electrical X No apparent defects Open junction box(es) Handyman wiringKnob and tube covered with insulation Safety Hazard
Comments Recommend extending bathroom vents to the exterior.
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 19
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
KitchenCountertops
Condition X Satisfactory Marginal Recommend repair/caulking
Comments
Photos
Cabinets
Condition X Satisfactory Marginal Recommend repair/adjustment
Comments
Plumbing
Faucet Leaks Yes X No
Pipes leak/corroded Yes X No
Sink/Faucet X Satisfactory Corroded Chipped Cracked Recommend repair
Functional drainage X Satisfactory Marginal Poor
Functional flow X Satisfactory Marginal Poor
Comments
Walls & Ceiling
Condition X Satisfactory Marginal Poor Typical cracks Moisture stains
Comments
Heating/Cooling Source
X Yes No
Comments
Floor
Condition X Satisfactory Marginal Poor Sloping Squeaks
Comments
Appliances
Disposal X N/A Not tested Operable: Yes No
Oven N/A Not tested Operable: X Yes No
Range N/A Not tested Operable: X Yes No
Dishwasher X N/A Not tested Operable: Yes No
Trash Compactor X N/A Not tested Operable: Yes No
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 20
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
KitchenAppliances cont.
Exhaust fan X N/A Not tested Operable: Yes No
Refrigerator N/A Not tested Operable: X Yes No
Microwave N/A Not tested Operable: X Yes No
Receptacles present X Yes No Operable: X Yes No
GFCI Yes X No Operable: Yes No Recommend GFCI Receptacles: X Yes NoPotential Safety Hazard(s)
Open ground/Reverse polarity: Yes X No Potential Safety Hazard
Comments Appliances only tested for operation, working or not. Quality or extent of operation not part of testing or inspection .
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 21
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Laundry RoomLaundry
Laundry sink Yes X No
Faucet leaks Yes X No X N/A
Pipes leak Yes X No Not Visible
Cross connections Yes X No Potential Safety Hazard
Heat source present X Yes No
Room vented X Yes No
Dryer vented through N/A X Wall Ceiling Floor Not vented Plastic dryer vent not recommendedNot vented to exterior Recommend repair Safety hazard
Electrical Open ground/reverse polarity: Yes X No Safety hazard
GFCI present Yes X No Operable: Yes No Recommend GFCI Receptacles
Appliances X Washer X Dryer Water heater Furnace/Boiler
Washer hook-up lines/valves X Satisfactory Leaking Corroded Not Visible
Gas shut-off valve N/A X Yes No Cap Needed Safety hazard Not Visible
Comments
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 22
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Living RoomLiving Room
Location NW corner 1st floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan X None Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 23
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Dining RoomDining Room
Location SW corner 1st floor.
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan X None Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Doors X None Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 24
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Master Bed RoomRoom
Location SE corner 1st floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor X Squeaks Slopes Tripping hazard
Ceiling fan None X Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Bedroom Egress restricted N/A Yes X No
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 25
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Bed Room (2)Room
Location NE corner 1st floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan None X Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Bedroom Egress restricted N/A Yes X No
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 26
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Bed Room (3)Room
Location North center 1st floor
Walls & Ceiling X Satisfactory Marginal Poor Typical cracks Damage
Moisture stains Yes X NoWhere:
Floor X Satisfactory Marginal Poor Squeaks Slopes Tripping hazard
Ceiling fan None X Satisfactory Marginal Poor Recommend repair/replace
Electrical Switches: X Yes No X Operable Receptacles: X Yes No X OperableOpen ground/Reverse polarity: Yes X No Safety hazard Cover plates missing
Heating source present X Yes No Holes: Doors Walls Ceilings
Bedroom Egress restricted N/A Yes X No
Doors None X Satisfactory Marginal Poor Cracked glass Broken/Missing hardware
Windows None X Satisfactory Marginal Poor Cracked glass Evidence of leaking insulated glassBroken/Missing hardware
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 27
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
BathroomBath
Location South center 1st floor
Sinks Faucet leaks: Yes X No Pipes leak: Yes X No
Tubs N/A Faucet leaks: Yes X No Pipes leak: Yes X No Not Visible
Showers N/A Faucet leaks: Yes X No Pipes leak: Yes X No Not Visible
Toilet Bowl loose: Yes X No Operable: X Yes No Cracked bowl Toilet leaks
Whirlpool Yes X No Operable: Yes No Not tested No access door GFCI: Yes X NoX GFCI Recommended
Shower/Tub area X Satisfactory Marginal Poor Rotted Floor
Shower/Tub Material X Ceramic/Plastic Fiberglass Masonite Other
Caulk/Grouting Needed N/A Yes X No
Drainage X Satisfactory Marginal Poor
Water flow X Satisfactory Marginal Poor
Moisture stains present Yes X No Walls Ceilings Cabinetry
Doors X Satisfactory Marginal Poor
Window None X Satisfactory Marginal Poor
Receptacles present X Yes No Operable: X Yes No
GFCI Yes X No Operable: Yes No X Recommend GFCI
Open ground/Reverse polarity Yes X No Potential Safety Hazard
Heat source present X Yes No
Exhaust fan X Yes No Operable: X Yes No Noisy
Comments Recommend venting exhaust fan to exterior Recommend GFCI outlet in bathroom.
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 28
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
BasementStairs
Condition X Satisfactory Marginal Poor Typical wear and tear Need repair Risers UnevenSafety Hazard
Handrail X Yes No Condition: X Satisfactory Loose Handrail/Railing/Balusters recommended
Headway over stairs Satisfactory X Low clearance Safety hazard
Comments Low Head Clearance at Bottom of Stairs Recommend at least 6'8".
Photos
Foundation
Condition Satisfactory Marginal Have evaluated Monitor X Not Visible
Material ICF Brick Concrete block Stone Masonry X Poured concrete wood
Horizontal cracks None North South East West X Not Visible
Step cracks None North South East West X Not Visible
Vertical cracks None North South East West X Not Visible
Covered walls None X North X South X East X West
Movement apparent X None North South East West
Indication of moisture Yes X No Fresh Old stains
Comments Foundation walls were covered with paneling/drywall and were not visible or able to be inspected.
Floor
Material X Concrete Dirt/Gravel X Not Visible Other
Condition Satisfactory Marginal Poor Typical cracks X Not Visible
Comments Concrete floor covered with tile and not visible. Could not inspect for cracks.
Seismic bolts
X N/A None visible
Condition Appear satisfactory Recommend evaluation
Comments
Drainage
Sump pump X Yes No X Working Not working Needs cleaning Pump not tested
Floor drains Yes X None Visible Drains not tested
Comments Two sumps in same hole
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 29
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
BasementDrainage cont.
Girders/Beams
Not Visible
Condition X Satisfactory Marginal Poor Stained/Rusted
Material Steel X Wood Concrete LVL Not Visible
Comments Can only view in southeast room. Tile ceiling elsewhere.
Columns
X Not Visible
Condition X Satisfactory Marginal Poor Stained/Rusted
Material X Steel Wood Concrete Block Not Visible
Comments Can only view one in southeast room.
Joists
Not Visible
Condition X Satisfactory Marginal Poor
Material X Wood Steel Truss Not Visible 2x8 X 2x10 2x12 Engineered I-TypeSagging/altered joists
Comments
Subfloor
X No Subfloor Has Subfloor
Condition Satisfactory Marginal Poor Indication of moisture stains/rotting
Comments
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 30
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
PlumbingWater service
Main shut-off location Bsmt closet Public Water Supply X Private Well Supply
Water entry piping Not Visible Copper/Galv. X PVC Plastic CPVC Plastic Polybutylene PlasticPEX Plastic Lead Polyethylene
Lead other than solder joints Yes X No Unknown Service entry
Visible water distribution piping X Copper Galvanized PVC Plastic CPVC Plastic Polybutylene PlasticPEX Plastic Other
Condition X Satisfactory Marginal Poor
Flow X Satisfactory Marginal Poor Water pressure over 80 psi Recommend plumber evaluateRecommend pressure regulator
Pipes Supply/Drain Corroded Leaking Valves broken/missing Dissimilar metalCross connection: Yes X No Safety Hazard Recommend repair
Recommend a dielectric union X Satisfactory
Drain/Waste/Vent pipe Copper X Cast iron Galvanized PVC ABS Brass
Condition Satisfactory X Marginal Poor
Support/Insulation N/AType: Metal strapping
Traps proper P-Type X Yes No P-traps recommended
Drainage X Satisfactory Marginal Poor
Interior fuel storage system N/A Yes X No Leaking: Yes No
Fuel line N/A Copper Brass X Black iron Stainless steel CSST Not Visible GalvanizedRecommend CSST be properly bonded
Condition X Satisfactory Marginal Poor Recommend plumber evaluate
Comments Cast iron pipe is 50 + years old and nearing end of life. Starting to flake on bottom.
Photos
Main fuel shut-off location
N/A
Location Outside NE corner
Comments Gas meter on exterior of home.
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 31
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
PlumbingWell pump
N/A
Type X Submersible In basement Well house Well pit Shared well
Pressure gauge operable X Yes No Well pressure: 40-60 psi Not Visible
Comments
Sanitary/Grinder pump
X N/A Operable: Yes No
Sealed Crock Sealed crock: Yes No
Check Valve Check valve: Yes No
Shut-off Valve Shut-off valve: Yes No
Vented Yes No
Comments
Water heater #1
N/A
General Brand Name: American Serial #: 123456Capacity: 50 Approx. age: 19
Type X Gas Electric Oil LP Other
Combustion air venting present X Yes No N/A
Seismic restraints needed X N/A Yes No
Pressure Relief valve X Yes NoExtension proper: Yes X No Missing Recommend repair Improper material
Cold Water Shuttoff Valve Yes X No
Vent pipe N/A X Satisfactory Pitch proper Improper Rusted Recommend repair
Condition X Satisfactory Marginal Poor
Comments Temperature-Pressure relief valve extension should be 4"-6" off of the floor - this is a Safety Concern. There should be a shut-off valve on cold water supply line for emergencies.
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 32
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Plumbing
Water softener
None
Loop installed Yes X No
Plumbing hooked up X Yes No
Plumbing leaking Yes X No
Comments Corrosion on water valves.
Photos
Corrosion on valves.
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 33
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Heating SystemHeating System Home
Unit #1 Brand name: Sears Approx. age: 5
Unknown Model #: 23A5664 Serial #: 45AF673-3 Satisfactory X Marginal PoorRecommended HVAC technician examine Location: West wall
Energy source X Gas LP Oil Electric Solid fuel
Ignition Source Within 18" of floor No X Yes
Warm air system Belt drive Direct drive Gravity Central system X Floor/wall furnace
Heat exchanger N/A Sealed Not Visible X Visual w/mirror Flame distortion RustedCarbon/soot buildup
Carbon monoxide X Not Detected Detected at plenum Detected at register Not tested
CO test Tester: Tiff 8900
Combustion air venting present N/A X Yes No
Controls Disconnect: X Yes No X Normal operating and safety controls observedGas shut off valve: X Yes No
Distribution X Metal duct Insulated flex duct Cold air returns Duct board Asbestos-like wrapSafety Hazard
Flue piping N/A X Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace
Filter Standard Electrostatic Satisfactory Needs cleaning/replacement MissingElectronic (not tested) X None Required
When turned on by thermostat X Fired Did not fire Proper operation: X Yes No Not tested
Heat pump X N/A Supplemental electric Supplemental gas
Sub-slab ducts X N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No
System not operated due to X N/A Exterior temperature Other
Comments Recommend no ignition source within 18" of floor in a garage unless it is of a Flammable Vapor Ignition Resistant (FVIR) DESIGN.
Heating System Garage
Unit #1 Brand name: Sears Approx. age: 15-20+
Unknown Model #: 45F5664A-0 Serial #: 345123 Satisfactory X Marginal PoorRecommended HVAC technician examine Location: Basement
Energy source X Gas LP Oil Electric Solid fuel
Warm air system Belt drive X Direct drive Gravity X Central system Floor/wall furnace
Heat exchanger N/A Sealed Not Visible X Visual w/mirror Flame distortion RustedCarbon/soot buildup
Carbon monoxide X Not Detected Detected at plenum Detected at register Not tested
CO test Tester: Tiff 8900
Combustion air venting present N/A X Yes No
Controls Disconnect: X Yes No X Normal operating and safety controls observedGas shut off valve: X Yes No
Distribution X Metal duct Insulated flex duct X Cold air returns Duct board Asbestos-like wrapSafety Hazard
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 34
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Heating SystemHeating System Garage cont.
Flue piping N/A X Satisfactory Rusted Improper slope Safety hazard Recommend repair/replace
Filter X Standard Electrostatic Satisfactory Needs cleaning/replacement MissingElectronic (not tested)
When turned on by thermostat X Fired Did not fire Proper operation: X Yes No Not tested
Heat pump X N/A Supplemental electric Supplemental gas
Sub-slab ducts X N/A Satisfactory Marginal Poor Water/Sand Observed: Yes No
System not operated due to X N/A Exterior temperature Other
Comments Furnace nearing end of life
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 35
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Electric/Cooling SystemMain panel
Location Panel located in laundry room in basement, inside cabinet.
Condition X Satisfactory Poor
Adequate Clearance to Panel Yes X No
Amperage/Voltage Unknown 60a X 100a 150a 200a 400a X 120v/240v
Breakers/Fuses Breakers X Fuses
Appears grounded X Yes No X Not Visible
GFCI breaker Yes X No Operable: Yes No Not Tested
AFCI breaker Yes X No Operable: Yes No Not Tested
Main wire X Copper Aluminum Not Visible Double tapping of the main wireCondition: X Satisfactory Marginal Poor
Branch wire X Copper Aluminum Solid Branch Aluminum Wiring Not Visible Safety Hazard
Branch wire condition X Satisfactory Poor Recommend electrician evaluate/repair X Romex BX cableConduit Knob/Tube Double tapping Wires undersized/oversized breaker/fusePanel not accessible Not evaluated
Reason:
Comments Panel appears to be grounded at meter box with ground rod. Not visible, in conduit. Panel was full and may need to be upgraded for future needs.
Photos
Panel inside left cabinet.
Sub panel(s)
None apparent
Location(s) Location 1: Garage, East wall next to door.
Panel Accessible X Yes NoReason Not:
Recommend separating/isolating neutrals Recommend electrician repair/evaluate box
Branch wire X Copper Aluminum Safety hazard Neutral/ground separated: X Yes NoNeutral isolated: X Yes No
Condition Satisfactory Marginal X Poor Not Evaluated
Comments Recommending grounding by qualified electrician. Safety hazard.
Photos
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
1538 W Greenleaf, Plainfield, IL 60586 Page 36
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC
Electric/Cooling System
Evaporator Coil Section Unit #1
N/A
General X Central system Wall unitLocation: In the basement , at bottom of stairs.
Age: 20-25+ Serial #: Not visible
Evaporator coil X Not Visible Needs cleaning Damaged
Refrigerant lines Leak/Oil present Damage Insulation missing X Satisfactory
Condensate line/drain To exterior To pump Floor drain X Sump
Secondary condensate line/drain Present: Yes X No Needed: Yes X No Primary pan appears cloggedRecommend technician evaluate
Operation Differential: 16
Condition Satisfactory X Marginal Poor Recommend HVAC technician examine/clean/serviceNot operated due to exterior temperature
Comments AC nearing end of life
This confidential report is prepared exclusively for John Doe©2015 Home Anatomy Inspection Services LLC