DUO I/O-Module BUS-2/BUS-1 DUO Switching Module 230 V AC / 8 A - 4 detector groups with clear function - 2 semiconductor outputs - 2 Relais outputs DUO I/O-Module BUS-2/BUS-1, f.m. DUO Switching Mod. 230 V AC / 8 A, f.m. DUO I/O-Module The DUO I/O-Module has the same function as detector groups and control modules. It can be operated at either BUS-2 or BUS-1. Detectors equipped with conventional connection technology can be integrated in the BUS system via the 4 detector group inputs with clear function (e.g. contacts and passive glass breakage sensors). The module is also equipped with 2 semiconductor outputs for switching and control functions (max. 30 V DC / 50 mA per output). For external consumers, the voltage of the module or an external voltage source can be used as operating voltage. Higher switching capacities (up to 250 V AC / 8 A) are possible in conjunction with the DUO Switching Module (see example on the right). DUO Switching Module Both relays can be activated via the outputs of the DUO I/O- Module or alternatively with another control voltage ("stand alone", see below). Voltage range: 9 V to 15 V DC. In combination with the DUO I/O-Module f.m., both modules are installed in two flush-mounted boxes that are positioned directly next to one another. A double cover frame is available as an accessory for this type of application. Features DUO Switching Module ! ! ! ! ! ! Activation of both relays via the DUO I/O-Module or "stand alone" 2 relay outputs each with one potential-free changeover contact Wide switching capacity range: 5 V DC / 10 mA to 250 V AC / 8 A 2 LEDs for status indication A LED (green) lights up as long as the corresponding relay is actuated. Visible from the outside or if required with individual cover. Simple installation in flush-mounted or cavity wall boxes 60 mm (DIN,Austria and Switzerland). VdS-approval Class C (IDS). Æ Example: Examples: Principle of activation "stand alone" Activation via DUO I/O module DUO I/O-Module DUO Switching Module DUO I/O-Module BUS-2/BUS-1, s.m. O1 O2 DG1 DG2 DG3 DG4 +12 V DC DUO I/O- Module +U 0 V BUS-2 or BUS-1 max. 50 mA per output Consumer Control panel 4 detector groups with clear function e.g. for contacts, passive glass breakage sensors 1 2 External voltage (max. 30 V DC) +12 V DC from BUS or DUO I/OModule ! ! ! ! ! ! ! ! Operation at BUS-2: Operation as 5-Input Module (compatibility mode) Operation as DUO I/O-Module. Operation at BUS-1: Operation either as zone interface, switching module or universal connection module. 4 Detector group inputs with clear function. 4 LEDs as detector group status indication or function freely programmable (depending on the operating mode). Visible from the outside or if required with individual cover. 2 semiconductor outputs, open collector, LOW active. Both outputs are activated simultaneously to LED1 and LED2 or function freely programmable (depending on the operating mode). Combined operation with the DUO Switching Module for high switching capacities. Simple installation of the f.m. module in flush-mounted or cavity wall boxes 60 mm (DIN, Austria and Switzerland). VdS-approval Class C (IDS). Æ DG1 DG2 DG3 DG4 +12 V DC DUO I/O- Module O1 O2 Rel1 Rel2 2 1 Rel1 Rel2 2 1 0 V +U DUO Switching Module Control panel BUS-2 or BUS-1 e.g. 230 V AC Consumer 9 V to 15 V DC e.g. 230 V AC Consumer DUO Switching Module

Upload: others

Post on 08-Jul-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Honeywell Commercial Security - DUO I/O-Module …...DUO I/O-Module BUS-2/BUS-1 DUO Switching Module 230 V AC / 8 A - 4 detector groups with clear function - 2 semiconductor outputs

DUO I/O-Module BUS-2/BUS-1

DUO Switching Module 230 V AC / 8 A

- 4 detector groups with clear function- 2 semiconductor outputs

- 2 Relais outputs

DUO I/O-ModuleBUS-2/BUS-1, f.m.

DUO Switching Mod.230 V AC / 8 A, f.m.

DUO I/O-ModuleThe DUO I/O-Module has the same function as detectorgroups and control modules. It can be operated at either BUS-2or BUS-1.

Detectors equipped with conventional connection technologycan be integrated in the BUS system via the 4 detector groupinputs with clear function (e.g. contacts and passive glassbreakage sensors).

The module is also equipped with 2 semiconductor outputs forswitching and control functions (max. 30 V DC / 50 mA peroutput). For external consumers, the voltage of the module oran external voltage source can be used as operating voltage.Higher switching capacities (up to 250 V AC / 8 A) arepossible in conjunction with the DUO Switching Module (seeexample on the right).

DUO Switching ModuleBoth relays can be activated via the outputs of the DUO I/O-Module or alternatively with another control voltage ("standalone", see below).Voltage range: 9 V to 15 V DC.

In combination with the DUO I/O-Module f.m., both modulesare installed in two flush-mounted boxes that are positioneddirectly next to one another. A double cover frame is availableas an accessory for this type of application.

Features

DUO Switching Module!

!

!

!

!

!

Activation of both relays via the DUO I/O-Module or "standalone"

2 relay outputs each with one potential-free changeovercontact

Wide switching capacity range:5 V DC / 10 mA to 250 V AC / 8 A

2 LEDs for status indicationA LED (green) lights up as long as the corresponding relay isactuated.Visible from the outside or if required with individual cover.

Simple installation in flush-mounted or cavity wall boxes

60 mm (DIN,Austria and Switzerland).

VdS-approval Class C (IDS).

Æ

Example:

Examples:

Principle of activation"stand alone"

Activation via DUO I/O module

DUO I/O-ModuleDUO Switching Module

DUO I/O-ModuleBUS-2/BUS-1, s.m.

O1

O2

DG1 DG2 DG3 DG4

+12 V DC

DUO I/O-Module

+U0 V

Alarmzentrale561-MB100

ZA509024X

VdS - Zulassungs-Nr.

Betrieb SAlarm SStörung

Info 4

Info 3

Info 2

Info 1

Pol.-Notruf

Überfall

Sabotage

Einbruch

System-Störung

0

1 2 3 M E

G F

B A

4 5 6

7 8 9ÜBERFALLFUNKTION

SONDERFUNKTION

Bereichewählen/ansehen

Meldungenansehen

Zusatz-funktionen

Gruppenansehen/sperren

Melderansehen/sperren

EingabeQuittierungBedienende

ALARMSTOPunscharflöschen

Internscharf-schaltenAUS EIN

nein ja

BUS-2or

BUS-1

max. 50 mAper output

Consumer

Control panel

4 detector groups with clear functione.g. for contacts, passive glass breakage sensors

1 2

External voltage(max. 30 V DC)

+12 V DC from BUSor

DUO I/OModule!

!

!

!

!

!

!

!

Operation at BUS-2:Operation as 5-Input Module (compatibility mode)Operation as DUO I/O-Module.

Operation at BUS-1:Operation either as zone interface, switching module oruniversal connection module.

4 Detector group inputs with clear function.

4 LEDs as detector group status indication or functionfreely programmable (depending on the operating mode).Visible from the outside or if required with individual cover.

2 semiconductor outputs, open collector, LOW active.Both outputs are activated simultaneously to LED1 andLED2 or function freely programmable (depending on theoperating mode).

Combined operation with the DUO Switching Module forhigh switching capacities.

Simple installation of the f.m. module in flush-mounted or

cavity wall boxes 60 mm (DIN, Austria and Switzerland).

VdS-approval Class C (IDS).

Æ

DG1 DG2 DG3 DG4

+12 V DC

DUO I/O-Module

O1

O2Alarmzentrale561-MB100

ZA509024X

VdS - Zulassungs-Nr.

Betrieb SAlarm SStörung

Info 4

Info 3

Info 2

Info 1

Pol.-Notruf

Überfall

Sabotage

Einbruch

System-Störung

0

1 2 3 M E

G F

B A

4 5 6

7 8 9ÜBERFALLFUNKTION

SONDERFUNKTION

Bereichewählen/ansehen

Meldungenansehen

Zusatz-funktionen

Gruppenansehen/sperren

Melderansehen/sperren

EingabeQuittierungBedienende

ALARMSTOPunscharflöschen

Internscharf-schaltenAUS EIN

nein ja

Rel1

Rel2

21

Rel1

Rel2

21

0 V

+U

DUO Switching ModuleControl panel

BUS-2or

BUS-1

e.g. 230 V AC

Consumer

9 V to 15 V DC

e.g. 230 V AC

Consumer

DUO Switching Module

Page 2: Honeywell Commercial Security - DUO I/O-Module …...DUO I/O-Module BUS-2/BUS-1 DUO Switching Module 230 V AC / 8 A - 4 detector groups with clear function - 2 semiconductor outputs

Technical Data

DUO I/O-ModuleRated operating voltage 12 V DC

Operating voltage range 9 V to 15 V DC

Current consumption at U_b=12 V DC:

- Detector groups open 5.0 mA

- Detector groups terminatd with 12k1 0.6 mA in addition per detector group

- LED indicator 1.3 mA in addition per LED

4 detector group inputs with clear function- Voltage 8 V DC, stabilized, short-circuit protected- Monitoring range 12k1 ± 20% (depending on the operating mode the values can be

changed)

2 semiconductor outputs "open collector", LOW active,max. 30 V DC, max. 50 mA per output

Rated operating voltage (relay) 12 V DC

Operating voltage range (relay) 9 V to 15 V DC

Current consumption at U_b=12 V DC 18.3 mA per relay

Relay contacts:- Type of contact Changeover contact, potential free- Switching capacity max. 8 A at 250 V AC (2000 VA) / 5 A at 30 V DC (150 W)

min. 5 V DC / 10 mA

Protection class as per DIN 40 050 IP 40

Environmental class as per VdS II

Operating temperature range -10 °C to +55 °C

Storage temperature range -25 °C to +70 °C

Dimensions:- Module s.m. (W x H x D) 85 x 109 x 30 mm- Modules f.m.:

- Mounting dimension ( x D) 58 x 26 mm- Mounting frame (W x H x D) 70 x 70 x 1 mm- Cover frame (W x H x D) 80 x 80 x 5 mm- 2-module cover frame (W x H x D) 151 x 80 x 5 mm

Colour Traffic white (similar to RAL 9016)

£

£

£

Æ

DOU Switching Module

General data

P02320-22-0G0-0511.2012 Subject to change without notice.© 2012 Honeywell International Inc.

"

Honeywell Security GroupNovar GmbH

Johannes-Mauthe-Str. 14 72458 Albstadt

Tel. +49(0) 74 31/801-0 Fax

"" 801-12 20

www.honeywell.com/security/de

[email protected]

Ordering informations

010120.17 010121.17

010124.17

010123.17

010130

010120.17 DUO I/O-Module BUS-2/BUS-1, f.m.

Item no. Description

010130 DUO I/O-Module BUS-2/BUS-1, s.m.

010121.17 DUO Switching Module 230V AC / 8A, f.m

Accessories

Item no. Description

010123.17 2-module cover frame for DUO-/Relay module

010124.17 Decorating foil

approval G109010

incl. Cover frame and Decorating foil

approval G109010

incl. Cover frame and Decorating foil

approval G109011

(PU = 2 pce.)

(PU = 4 pce. with 4 holes, 1 pce. with 2 holes)