honeywell security - · pdf file5800rp wireless repeater module 0100 5800tm wireless xmtr...

4

Upload: phamcong

Post on 30-Jan-2018

232 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Honeywell Security - · PDF file5800RP wireless repeater module 0100 5800TM wireless xmtr module 0 0 20 0 0 0 5881EN receiver 0 0 60 0 0 0 5883 hi-security receiver 0 0 80 0 0 0
Page 2: Honeywell Security - · PDF file5800RP wireless repeater module 0100 5800TM wireless xmtr module 0 0 20 0 0 0 5881EN receiver 0 0 60 0 0 0 5883 hi-security receiver 0 0 80 0 0 0
Page 3: Honeywell Security - · PDF file5800RP wireless repeater module 0100 5800TM wireless xmtr module 0 0 20 0 0 0 5881EN receiver 0 0 60 0 0 0 5883 hi-security receiver 0 0 80 0 0 0

version 1.059 (9/15/2011)

Honeywell SecurityBattery

ContigencyFactor

Battery & Power Budget Calculator Location: 24© 2003 Honeywell International Inc. All Rights Reserved Account #: 5

Model:Engineer: Recommended

Date: Battery (AH)

Select Panel from pulldown list:Polling

Loop (mA)

StandbyAuxiliary

Power (mA)

Alarm AuxiliaryPower (mA)

PanelStandby

(mA)

PanelAlarm (mA)

Bell #1Output(mA)

Bell #2Output (ifused; mA)

Maximum PanelStandby Output

Maximum PanelAlarm Output

Max BatterySupported by

Panel

128 750 1000 300 470 1700 1700 1300 2800 34.4Total Standby Total Alarm

Calculated Current Draw 0 45 150 Calculated Bell Draw 8 12 45 170Standby Budget Alarm Budget

Power Budget 128.0 705.0 850.0 Bell Power Budget 1692.0 1688.0 1255.0 2630.0Current OK Current OK Current OK Current OK Current OK Current OK

External Bell Power Req'd (mA): Ext. UL Power Req'd (mA): 0.0

KEYPADS/INTERFACESEnter

Quantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent Total Alarm Current

Total ExternalCurrent Required

6128 0 0 30 45 0 0 06128RF 0 0 60 120 0 0 06137 0 0 40 85 0 0 06139/6139R 0 0 40 100 0 0 06148 0 0 30 55 0 0 06149EX 0 0 40 60 0 0 06150 0 0 40 70 0 0 06150RF 0 0 80 105 0 0 06150V 0 0 60 160 0 0 06150RF 0 0 80 105 0 0 06160/6160CR 1 0 45 150 45 150 06160CR-2 0 0 45 160 0 0 06160PX 0 0 40 165 0 0 06160RF 0 0 50 150 0 0 06160V 0 0 60 190 0 0 06164US 0 0 55 210 0 0 06165EX 0 0 40 70 0 0 06270 0 0 180 280 0 0 06271C 0 0 159 230 0 0 06271CV 0 0 159 230 0 0 06271V 0 0 137 210 0 0 06272CV 0 0 180 305 0 0 06272CSV 0 0 180 305 0 0 06272CBV 0 0 180 305 0 0 06460S 0 0 40 150 0 0 06460W 0 0 40 150 0 0 08132iPK (Symphony) 0 0 350 400 0 0 0FSA-8 Fire Zone Annunciator 0 0 35 65 0 0 0FSA-24 Fire Zone Annunciator 0 0 35 130 0 0 0Add'l Keypd (Enter # and Currents) 0 0 0 0 0 0 0Add'l Keypd (Enter # and Currents) 0 0 0 0 0 0 0

2 WIRE & 4 WIRE SMOKE DETECTORS(except Vplex Polling Loop detectors)

EnterQuantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent Total Alarm Current

Total ExternalCurrent Required

2 wire smoke detector (zone powered) 972 wire smoke detector (zone powered) 472 wire smoke detector (zone powered) 02 wire smoke detector (zone powered) 012V 4 Wire Smoke (Qnt'y & Currents) 0 0 0 0 0 0 012V 4 wire Smoke ( Qnt'y & Currents) 0 0 0 0 0 0 012V 4 wire Smoke ( Qnt'y & Currents) 0 0 0 0 0 0 012V 4 wire Smoke ( Qnt'y & Currents) 0 0 0 0 0 0 0

Enter Standby and Alarm TimesFacility InformationBattery Standby (hours):

Alarm Duration (minutes):WATERSIDE

855/8918

Grayed-out device(s) are not supported by selected panel

Recommended Battery Capacity OK for 48-Hr Recharge

Panel Max Output Exceeded if highlighted

SELECTED PANEL MAXIMUM OUTPUT RATINGS

0.0

Power Overdraw if highlighted

Two-wire smoke detector current is built into the panel budgets. These fields are included to help youcreate a complete equipment list. The line below indicates if number of detectors exceeds panelcapacity, or if the selected panel does not support 2-wire smoke detectors.

Quantity of 2 Wire Smoke Detectors OK for selected panel!

FB32Elite Fire Alarm

3/21/20179.7

Vista-32FB

Using Relay?

Commercial Fire Installation

Commercial Burg Installation

10%

Remove Unused Devices From List

Using Relay?

MULTI-POWER DEVICESEnter

Quantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent Total Alarm Current

Total ExternalCurrent Required

4208U [powered by polling loop] 0 0 0 0 27.3 0 0 0 04208U [powered by panel aux power] 0 0 28 0 0.6 0 0 0 04208U [powered externally] 0 0 28 0 0.6 0 0 0 04208SN [powered by polling loop] 0 0 0 0 33.6 0 0 0 04208SN [powered by panel aux power] 0 0 33 0 0.6 0 0 0 04208SN [powered externally] 0 0 33 0 0.6 0 0 0 04208SNF [powered by polling loop] 0 0 0 0 33.6 0 0 0 04208SNF [powered by panel aux power] 0 0 40 0 0.6 0 0 0 04208SNF [powered externally] 0 0 40 0 0.6 0 0 0 04208SNF (Class B to A Zone Converter) 0 0 40 0 0 0 0 0 04209U Grouped Zone Mux. Module 0 0 110 0 15.5 0 0 0 04209U [powered externally] 0 0 110 0 15.5 0 0 0 04297 Polling Loop Extender 0 0 178 0 0 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0 0 0

AUXILIARY POWERED DEVICESEnter

Quantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent Total Alarm Current

Total ExternalCurrent Required

PS24 24 volt Power Supply Module 0 0 50 100 0 0 04100SM (no more than one per system) 0 0 25 0 0 0 04204: Enter no. of relays used 0 0 40 0 0 0 04204CF:Enter no. of relays used 0 0 80 0 0 04285 Voice Module 0 0 160 0 0 04286 with warning speakers 0 0 220 300 0 0 05140DLM Backup Dialer Module 0 0 5 15 0 0 05800RP wireless repeater module 0 0 100 0 0 05800TM wireless xmtr module 0 0 20 0 0 05881EN receiver 0 0 60 0 0 05883 hi-security receiver 0 0 80 0 0 0UVS-QM 0 0 75 110 0 0 0VA8200 Panel Linking Module 0 0 88 0 0 0 0VA8201 Alpha Pager Module 0 0 165 0 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0Communicators7845GSM/7845i-GSM 0 0 10 0 0 07845i/7845i-ENT 0 0 10 0 0 0GSMCF/iGSMCF Fire Communicator 0 0 10 0 0 0Vista-GSM/Vista-GSMCN (Vista-21iP only) 0 0 10 0 0 07847i/7847i-E Internet Communicator 0 0 75 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0Add'l Device (enter quant. & currents) 0 0 0 0 0 0 0PIR Motion Detectors (non Vplex)IS215T 0 0 7 0 0 0IS215TCE 0 0 18 0 0 0IS2260/IS2260T 0 0 4 0 0 0IS2460 0 0 9 0 0 0IS2500LT 0 0 25 0 0 0IS2535/IS2535T 0 0 20 0 0 0IS2560/IS2560T 0 0 20 0 0 0IS2560TC 0 0 25 0 0 0IS310/IS320 Request to Exit (RTE) 0 0 35 0 0 0997 Ceiling Mount PIR 0 0 12 0 0 0998 Wall Mount PIR 0 0 13 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Dual Tech Motion Detectors (non Vplex)DT-515 0 0 20 0 0 0 0DT-6100STC 0 0 35 0 0 0 0DT-7235T 0 0 20 0 0 0 0DT-7435/DT-7435C 0 0 30 0 0 0 0DT-7450/DT-7450MIC 0 0 35 0 0 0 0DT-7550 0 0 40 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0Motion Detctrs (enter quant. & currents) 0 0 0 0 0 0 0

Power Overdraw if highlighted

Panel Max Output Exceeded if highlighted

Panel Max Output Exceeded if highlighted

Power Overdraw if highlighted

LED Active?

LED Active?

LED Active?

LED Active?

POLLING LOOP DEVICESEnter

Quantity

How manypowered by

4297?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent Total Alarm Current

Total ExternalCurrent Required

4101SN Single Output Relay Module 0 0 7 04190SN Two Zone SIM 0 0 2 04190WH 0 0 2 04191SN-WH 0 0 0.5 04192CP 0 0 0.4 04192SD Photoelectric Smoke Det. 0 0 0.4 04192SDT 0 0 0.4 04193SN Two Zone SIM 0 0 1.5 04194 Contact 0 0 1 04196 0 0 1 04209U 0 0 15.5 04275EX Dual PIR 0 0 1 04275EX-SN Dual PIR 0 0 1 04278EX-SN 0 0 1 0DT7500SN 0 0 2.6 04293SN 0 0 1 04939SN WH/BR/GY Surf Mt. Cntct. 0 0 1 04944SN Recessed Contact 0 0 1 04945SN-WH 0 0 0.5 04959SN Overhead Door Contact 0 0 0.5 05192SD Smoke Detector 0 0 1.2 05192SDT Smoke w/ Heat 0 0 1.2 05193SD Smoke Detector 0 0 1.2 05193SDT Smoke w/ Heat 0 0 1.2 0998MX PIR 0 0 1 0IS2500SN PIR 0 0 1.6 0FG-1625SN Glass Break Detector 0 0 1 0Quest2260SN 0 0 6 0Vplex-VSI Short Isolator 0 0 5 0Vistakey 0 0 2 0Add'l VPlex (enter qnt'y & current) 0 0 0 0Add'l Vplex (enter qnt'y & current) 0 0 0 0

12V NOTIFICATION DEVICES ONBELL OUTPUT #1

EnterQuantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent

Total SounderCurrent from Panel

Bell #1Total Sounder

Current (external)

Enter device name, quant., & current 8 0 2 8 0Enter device name, quant., & current 0 0 0 0 0Enter device name, quant., & current 0 0 0 0 0Enter device name, quant., & current 0 0 0 0 0Enter device name, quant., & current 0 0 0 0 0

12V NOTIFICATION DEVICES ONBELL OUTPUT #2 (IF USED)

EnterQuantity

How manypowered

externally?Standby (aux

pwr)Alarm

Current (Aux) Polling LoopTotal Polling

Loop

TotalStandbyCurrent

Total SounderCurrent from Panel

Bell #2Total Sounder

Current (external)

Enter device name, quant., & current 86 0 2 12 0Enter device name, quant., & current 0 0 0 0Enter device name, quant., & current 0 0 0 0 0Enter device name, quant., & current 0 0 0 0 0Enter device name, quant., & current 0 0 0 0 0

12V AUX POWER AND BELL CIRCUITWIRE RUN DATA Units

Ohms per1000 ft

Alarm CurrentDraw (mA) Run Length

ActualResistance(twin leads) Voltage At EOL

Voltage Drop(Percent)

Un

itS

ele

ctio

n

Panel Aux Power Wire Run (twin lead) 8.08 150.00 45 0.73 11.89 0.91

Panel Bell 1 Wire Run (twin lead) 8.08 8.00 95 1.54 11.99 0.10

Panel Bell 2 Wire Run (twin lead) 8.08 12 160 2.59 11.97 0.26

Panel Max Output Exceeded if highlightedPolling Loop Overdraw if highlighted! Add 4297 Devices (row 41)

Bell #1 Power Overdraw if highlighed! Panel Max Output Exceeded if highlighted

Bell #2 Power Overdraw if highlighed! Panel Max Output Exceeded if highlighted

Wire Gauge(AWG)

grayed-out devices are not supported by selected panel

LED Active?

LED Active?

LED Active?

LED Active?

#18 AWG SolidFeet

Feet #18 AWG Solid

Feet #18 AWG Solid

LED Active?

LED Active?

LED Active?

LED Active?

LED Active?

LED Active?

LED Active?

PS24 Power SupplyBattery & Power Budget Calculator 24

© 2003 Honeywell International Inc. All Rights Reserved 51.059

Panel 12VStandby (mA)

Panel 12VAlarm (mA)

Output AStandby (mA)

Output AAlarm (mA)

Output BStandby (mA)

Output BAlarm(mA)

PS24 PCBoard (mA)

Maximum TotalStandby Output

Maximum TotalAlarm Output

Max. BatteryCapacity

345 640 570 1700 570 1700 40 610 4180 34.4Total Standby Total Alarm

Equivalent panel load @ 24V 0.0 0.0 0 0 0 0 40 40 40(converted to 12VDC from 24V full-wave) Standby Budget Alarm Budget

Power Budget 345.0 640.0 570.0 1700.0 570.0 1700.0 570.0 4140.0 34.4Current OK 0 Current OK Current OK

24V NOTIFICATION APPLIANCESEnter Device Names & Specifications

EnterQuantity

Which PS24Output?

DeviceStandby Load

(MA)Device Alarm

Load (MA)Subtotal AStandby

Subtotal AAlarm Subtotal B Standby Subtotal B Alarm

Ou

tpu

tS

ele

ctio

n

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V Notification Appliance 0 0 0 0 0 0 0 0

24V BELL CIRCUIT WIRE RUN DATA UnitsOhms per1000 ft

Total AlarmCurrent Draw

(mA) Run Length

ActualResistance(twin leads) Voltage At EOL

Voltage Drop(Percent)

Un

itS

ele

ctio

n

PS24 Output A Wire Run (twin lead) 0.00 0.00 0 0.00 24.00 0.00

PS24 Output B Wire Run (twin lead) 0.00 0.00 0 0.00 24.00 0.00

Recommended Battery Capacity OK for 48-Hr Recharge

Alarm Duration (minutes):

Standby/Alarm Durations (from top)Battery Standby (hours):

7.0Use TWO identical batteries w/ this AH capacity

Required Capacity (AH)

PS24 POWER SUPPLY MODULE, MAXIMUM CAPACITIES

Wire Gauge(AWG)

<Select Wire Gauge>Feet

Feet <Select Wire Gauge>

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Output A

Using PS24 to back up Control Panel

Page 4: Honeywell Security - · PDF file5800RP wireless repeater module 0100 5800TM wireless xmtr module 0 0 20 0 0 0 5881EN receiver 0 0 60 0 0 0 5883 hi-security receiver 0 0 80 0 0 0

N E W G E N E R A T I O N ® C A B L E S 20.8

F o r m o r e i n f o r m a t i o n , c o n t a c t B e l d e n Te c h n i c a l S u p p o r t : 1 - 8 0 0 - B E L D E N - 1 • w w w . b e l d e n . c o m

Unshielded Multi-conductorCM FT1 Rated

Product Description

Bare copper conductors, polypropylene insulation,PVC jacket. Available in Beige, Brown, Orange,Yellow, Green, Blue, Purple, Gray or White jacketcolors (except as noted in footnote). Conductorsmay not be cabled. Sequential footage markingevery two feet.

Color Code: See chart below.

Specifications

Conductor Bare Copper

Insulation Polypropylene

Insulation Thickness .006″ (.152mm)

Jacket PVC

ApprovalsNEC CMCEC CM FT1

NEC Articles 800

Voltage Rating 300V

Temperature Rating 75°C

Applications• Security Systems

• Intercom/PA Systems

• Sound/Audio Systems

• Power-Limited Controls

• Single Line Telephone

• Station Wire (5582UG)

Solid Conductor

Stranded Conductor

StrandingNo. of Cond.

mFt.

StandardLengths

mmInchkg

Standard Unit Weight

Outer JacketThickness Nominal OD

Inch mmLbs.

Security and Alarm CableResidential, Light Commercial and Institutional ApplicationsUnshielded

PartNo.

Unshielded Multi-conductor (NEC CM and CEC CM FT1)

22 AWG5500UG* 2 7 C-500 C-152 3.5 1.6 .015 .38 .114 2.90

U-500 U-152 5.0 2.3C-1000 C-305 7.0 3.2U-1000 U-305 9.0 4.1

5582UG** 4 solid C-500 C-152 6.0 2.7 .015 .38 .122 3.10C-1000 C-305 12.0 5.4U-1000 U-305 13.0 6.0

5502UG 4 7 C-500 C-152 6.5 3.0 .015 .38 .131 3.33U-500 ▲ U-152 7.5 3.4

C-1000 C-305 13.0 6.0U-1000 U-305 14.0 6.4

5522UG† 4 solid C-500 C-152 6.0 2.7 .015 .38 .122 3.10u C-1000 C-305 12.0 5.45520UG 2 solid C-500 ◆ C-152 3.5 1.6 .015 .38 .106 2.69u C-1000 C-305 7.0 3.218 AWG

5300UG†† 2 7 C-500 C-152 7.5 3.4 .015 .38 .148 3.76U-500 U-152 8.5 3.9

U-1000 U-305 16.0 7.3* U-1000 available in Brown, Gray or Natural only.

** 5582UG available in Brown, Gray, White or Beige only.† 5522UG available in White only.

†† 5300UG available in Gray, Black or Natural only.▲ 5502UG U-500 ft. put-up available in Gray or White only.◆ 5520UG C-500 ft. put-up available in Gray or White only.

Color Code Chart ▼

(5500UG, 5502UG, 5520UG, 5522UG, 5300UG)

Cond. No. Color

1 Black

2 Red

3 White

4 Green▼Except 5582UG which is Black, Red, Yellow, Green

for use as station wire.

Color Code Chart(5582UG)

Cond. No. Color

1 Black

2 Red

3 Yellow

4 Green

Designed to integrate seamlessly with CCTV, access control

and Honeywell’s full range of fire and burglary components,

the new VISTA-32FB provides the ultimate protection of life

and property. The UL Listed commercial fire and burglary

control panel supports up to two partitions and up to

32 zones/points using hardwired, wireless and V-Plex®

addressable technologies. A diverse line of Honeywell

initiating devices, notification circuits, communication devices,

keypads, RF receivers and relays are also supported.

The VISTA-32FB has been designed to mount quickly

and easily.

• Supports addressable V-Plex accesscontrol points using VistaKey(One to Four doors)

• Supports eight hardwired zones,24 V-Plex addressable points/zones,or 32 wireless points/zones

• Can control two separate areas(partitions) independently

• Stores up to 512 events and canaccommodate 75 user codes

• Easily programmed and maintainedwith newly upgraded CompassDownloader Software

• Automatic smoke detector sensitivitymaintenance testing

• Commercial Wireless Fire andBurglary

• Notification Appliance Circuits (two):– Programmable– Individually silenceable

• Carbon monoxide (CO) zone support(Rev 5 and higher)

• Programmable on-board auxiliaryrelay

• False alarm reduction features:– Exit error logic– Exit delay reset– Cross zoning– Call waiting defeat– Recent close report

• Supports commercial hardwired,addressable V-Plex polling loopand wireless zones

• Listed to UL864 9th Edition (Rev 5and higher)

FEATURES

VISTA-32FBCOMMERCIAL PARTITIONED FIRE ANDBURGLARY ALARM CONTROL PANEL

Now UL864 9th Edition Approved

VISTA-32FBCOMMERCIAL PARTITIONED FIRE ANDBURGLARY ALARM CONTROL PANEL

• Hardwired zones– Provides nine style B hardwired

zones

– EOLR supervised for Fire and ULburglary installations

– Supports N.O. or N.C. sensors

– Individually assignable to one ofeight partitions

– Up to 16 two-wire smoke detectorseach on zone one and two (32 total)

• Patented addressable V-Plex pollingloop technology– Supports up to 24 two-wire V-Plex

zones/points

– Global polling technology forfaster processing

– Supervised by panel

– Individually assignable to partitions,notification circuit (bell) output oraux relay

– 4,000 ft. capability without the useof shielded cable

– Extender/Isolation bus modules

– Two-wire smoke detectorzone/group expansion moduleadds two or four zones

– Eight zone – Class A and Bextender module

– Eight zone – Class B extendermodule

– One zone supervised contactmonitor module

• UL Listed wireless expansion– Supports up to 32 wireless zones/

points using 5881ENHC or5883H Receiver

– Supervised by control forcheck-in signals

– Tamper protection for transmitters

– Individually assignable up toeight partitions

– Supports wireless smoke detectors

• Event reporting

• Local printer for access orVISTA related event

• Up to four doors using VistaKeyV-Plex Access Control

• Stored events for one call retrieval

• Communication– Panel operation during download

– Split/Dual Reporting

Applications

The VISTA-32FB control is well suitedfor a variety of applications as anintegrated fire and burglary control.Some of the applications supported are:medical and professional buildings,churches or synagogues, officebuildings, schools, strip malls,residences and factory or warehouseenvironments.

Installation

The VISTA-32FB alarm system hasbeen designed to mount both quicklyand easily. It meets all applicablerequirements for UL commercial fireand burglary installations.

ADDITIONAL FEATURES

Electrical

• Primary power: 18VAC @ 72VAADEMCO No. 1451

• Quiescent current draw: 300mA

• Backup battery:– 12VDC, 7AH min to 34.4AH max– Lead acid battery (gel type)

• Alarm power: 12VDC, 1.7A max foreach notification (bell) circuit output

• Aux. standby pwr: 12VDC, 1A max

• Total power: 2.3A at 12VDC,3.4A at 24VDC from all sources

• 24 hours with 1A standby load

Fusing

• Battery input, aux. and notification(bell) circuit outputs are protectedusing PTC circuit protectors. Alloutputs are power limited.

Main Dialer

• Line seize: Double Pole

• Ringer equiv.: 0.7B

• Formats: ADEMCO Low Speed,ADEMCO 4+2 Express, ADEMCOHigh Speed, ADEMCO Contact ID,Sescoa and Radionics

Cabinet dimensions

• 14.5" H X 12.5" W X 3" D

Environmental

• Storage temp: 14° F to 158° F(-10° C to 70° C)

• Operating temp: 32° F to 122° F(0° C to 50° C)

• Humidity: 85% RH

• EMI: Meets or exceeds thefollowing requirements:– FCC Part 15, Class B Device– FCC Part 68– IEC EMC Directive

Agency Listings

• FCC Part 15, Class B; FCC Part 68

• UL864/NFPA 72, Central Station andRemote Station (Fire)

• UL609 Local MercantilePremises/Mercantile Safe & Vault

• UL365 police station connectedburglar alarm

• UL610 Central StationBurglar Alarm

• California State Fire Marshal

• FM

• CAN/ULC S304 – Central andMonitoring Station Burglar Alarm Unit

• CAN/ULC S527 – Central Unit forFire Alarm Systems

• CAN/ULC S303 – Local BurglarAlarm Unit

• CAN/ULC S525 – Audible SignalAppliances

SPECIFICATIONS

6160 ALPHA DISPLAY KEYPAD

CO06010 L/6160/D September 2006 © 2006 Honeywell International Inc.

Honeywell Security & Custom Electronics Honeywell International Inc.PO Box 9035Syosset, NY 11791

www.honeywell.com

ORDERING 6160 Alpha Display Keypad

The 6160 Deluxe Keypad is easy to install and simple to

use. The attractive white console blends with any décor and

features a contoured, removable door that conceals

illuminated soft-touch keys. The 6160 also features a new

larger and brighter 32-character display with easy-to-read

plain-English status messages.

The oversized function keys are easily accessed even when

the keypad door is closed, and can be programmed for fire,

burglary, personal emergencies and other operations. Colored

self-adhesive labels are included.

• Large, easy-to-use keypad

• Keys continuously backlit for greater

visibility

• Speaker with audible beeps

to indicate:

- System status

- Entry/exit delay

- Other alarm situations

• Zones and system events displayed

in plain English

• No confusing blinking lights

• Four programmable function keys

• System functions clearly labeled

• Functions performed by just entering

security code plus command

• White with removable door blends

with any décor

FEATURES

Physical

• 5-5/16"H x 7-3/8"W x 1-3/16"D

(135mm x 190mm x 30mm)

Current

• Standby-40mA

• Activated Transmission-160mA

Wiring

• - (Black): Ground

• + (Red): +12 VDC (Aux. Power)

• D1 (Green): “Data in” to control panel

• D0 (Yellow): “Data out” from

control panel

Compatibility

• Fully compatible with all

VISTA controls.

SPECIFICATIONS

WITH DOOR ATTACHED

WITHOUT DOOR

Agency Listings

PhotoelectricSmoke Detectors

System Sensor i3™ series smoke detectors represent

significant advancement in conventional detection.

The i3 family is founded on three principles: installation

ease, intelligence, and instant inspection.

FeaturesPlug-in detector line, mounting base included•

Large wire entry port•

In-line terminals with SEMS screws•

Mounts to octagonal and single-gang back boxes, 4-square back •boxes, or direct to ceiling

Stop-Drop ’N Lock attachment to base•

Removable detector cover and chamber•

Built-in remote maintenance signaling•

Drift compensation and smoothing algorithms•

Simplified sensitivity measurement •

Wide-angle, dual-color LED indication•

Loop testing via EZ Walk feature•

Built-in test switch•

Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action.

Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED-indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration.

Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector.

2093290-01-E7272-1653:1523011446S911 3180932

3825OhioAvenue•St.Charles,IL60174 Phone:800-SENSOR2•Fax:630-377-6495

©2009 System Sensor.Product specifications subject to change without notice. Visit systemsensor.com for

current product information, including the latest version of this data sheet.A05-0318-007•6/09•#2169

Ordering InformationModel Thermal Wiring Alarm Current2W-B No 2-wire 130 mA max. limited by control panel

2WT-B Yes 2-wire 130 mA max. limited by control panel

4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24 V

4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24 V

Accessories2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool

SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter

Smoke Detector SpecificationsArchitectural/Engineering Specifications

Smoke detector shall be a System Sensor i3Seriesmodelnumber_______,listedtoUnderwritersLaboratoriesUL268forFireProtectionSignalingSystems.Thedetectorshallbeaphotoelectrictype(Model2W-B,4W-B)oracombinationphotoelectric/thermal(Model2WT-B,4WT-B)withthermalsensorratedat135°F(57.2°C).Thedetectorshallincludeamountingbaseformountingto3½-inchand4-inchoctagonal,single-gang,and4-inchsquarebackboxeswithaplasterring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual-color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually.

Electrical SpecificationsOperating Voltage Nominal: 12/24 V non-polarized

Minimum: 8.5 V Maximum: 35 V

Maximum Ripple Voltage 30% peak to peak of applied voltage

Standby Current 2-wire: 50 µA maximum average; 4-wire: 50 µA maximum average

Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24 V

Peak Standby Current 2-wire: 100 µA; 4-wire: n/a

Alarm Contact Ratings 2-wire:n/a;4-wire:0.5A@30VAC/DC

Physical SpecificationsDimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height

Weight 6.3 oz (178 g)

Operating Temperature Range 2W-Band4W-B:32°Fto120°F(0°Cto49°C);2WT-Band4WT-B:32°Fto100°F(0°Cto37.8°C)

Operating Humidity Range 0 to 95% RH non-condensing

Thermal Sensor 135°F(57.2°C)fixed

Freeze Trouble 2WT-Band4WT-Bonly:41°F(5°C)

Sensitivity 2.5%/ft nominal

Input Terminals 14 to 22 AWG

Mounting 3½-inchoctagonalbackbox 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling

LED Modes Power-Up Sequence for LED IndicationLED Mode Green LED Red LED Condition DurationPower up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds

Normal (standby) Blink every 5 seconds off

Out of sensitivity off Blink every 5 seconds

Freezetrouble off Blink every 10 seconds

Alarm off Solid

DF-52004:A1 • 04/22/08 — Page 1 of 2

BG-12 SeriesManual Fire Alarm Pull Stations

Conventional Initiating Devices

DF-52004:A1 • F-050

GeneralThe Fire·Lite BG-12 Series is a cost-effective, feature-packedseries of non-coded manual fire alarm pull stations. It wasdesigned to meet multiple applications with the installer andend-user in mind. The BG-12 Series features a variety of mod-els including single- and dual-action versions.

The BG-12 Series provides Fire·Lite Alarm Control Panels(FACPs), as well as other manufacturers’ controls, with a man-ual alarm initiating input signal. Its innovative design, durableconstruction, and multiple mounting options make the BG-12Series simple to install, maintain, and operate.

Features• Aesthetically pleasing, highly visible design and color.• Attractive contoured shape and light textured finish.• Meets ADA 5 lb. maximum pull-force.• Meets UL 38, Standard for Manually Actuated Signaling Boxes.• Easily operated(single- or dual-action), yet designed to pre-

vent false alarms when bumped, shaken, or jarred.• PUSH IN/PULL DOWN handle latches in the down position to

clearly indicate the station has been operated.• The word “ACTIVATED” appears on top of the handle in

bright yellow, further indicating operation of the station.• Operation handle features white arrows showing basic opera-

tion direction for non-English-speaking persons.• Braille text included on finger-hold area of operation handle

and across top of handle.• Multiple hex- and key-lock models available.• U.S. patented hex-lock needs only a quarter-turn to lock/

unlock.• Station can be opened for inspection and maintenance with-

out initiating an alarm.• Product ID label viewable by simply opening the cover; label

is made of a durable long-life material.• The words “NORMAL” and “ACTIVATED” are molded into the

plastic adjacent to the alarm switch (located inside).• Four-position terminal strip molded into backplate.• Terminal strip includes Phillips combination-head captive 8/32

screws for easy connection to Initiating Device Circuit (IDC).• Terminal screws backed-out at factory and shipped ready to

accept field wiring (up to 12 AWG/3.1 mm²).• Terminal numbers are molded into the backplate, eliminating

the need for labels.• Switch contacts are normally open.• Can be surface-mounted (with SB-10 or SB-I/O) or semi-

flush mounted. Semi-flush mount to a standard single-gang,double-gang, or 4" (10.16 cm) square electrical box.

• Backplate is large enough to overlap a single-gang backboxcutout by 1/2" (1.27 cm).

• Optional trim ring (BG12TR).• Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP).• Designed to replace the Fire·Lite legacy BG-10 Series.• Models packaged in attractive, clear plastic (PVC), clam-

shell-style, Point-of-Purchase packages. Packaging includesa cutaway dust/paint cover in shape of pull station.

Construction• Cover, backplate and operation handle are all molded of

durable polycarbonate material.• Cover features white lettering and trim.• Red color matches System Sensor’s popular SpectrAlert®

Advance horn/strobe series.

OperationThe BG-12 manual pull stations provide a textured finger-holdarea that includes Braille text. In addition to PUSH IN and PULLDOWN text, there are arrows indicating how to operate the sta-tion, provided for non-English-speaking people.

Pushing in and then pulling down on the handle activates thenormally-open alarm switch. Once latched in the down position,the word “ACTIVATED” appears at the top in bright yellow, with aportion of the handle protruding at the bottom as a visible flag.Resetting the station is simple: insert the key, twist one quarter-turn, then open the station’s front cover, causing the spring-loaded operation handle to return to its original position. Thealarm switch can then be reset to its normal (non-alarm) positionmanually (by hand) or by closing the station’s front cover, whichautomatically resets the switch.

52004p4c.jpg

Page 2 of 2 — DF-52004:A1 • 04/22/08

This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate.

We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.

For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105.www.firelite.com

Fire•Lite® Alarms, SpectrAlert® Advance, and System Sensor® areregistered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited.

Made in the U.S. A.

Specifications

PHYSICAL SPECIFICATIONS:

ELECTRICAL SPECIFICATIONS:Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC orVDC.

ENGINEERING/ARCHITECTURAL SPECIFICATIONSManual Fire Alarm Stations shall be non-code, with a key- orhex-operated reset lock in order that they may be tested, and sodesigned that after actual Emergency Operation, they cannot berestored to normal except by use of a key or hex. An operatedstation shall automatically condition itself so as to be visuallydetected as activated. Manual stations shall be constructed ofred colored LEXAN (or polycarbonate equivalent) with clearlyvisible operating instructions provided on the cover. The wordFIRE shall appear on the front of the stations in white letters,1.00 inches (2.54 cm) or larger. Stations shall be suitable forsurface mounting on matching backbox SB-10 or SB-I/O; orsemi-flush mounting on a standard single-gang, double-gang, or4" (10.16 cm) square electrical box, and shall be installed withinthe limits defined by the Americans with Disabilities Act (ADA) orper national/local requirements. Manual Stations shall be Under-writers Laboratories listed.

NOTE: *The words “FIRE/FUEGO” on the BG-12LSP shall appearon the front of the station in white letters, approximately 3/4"(1.905 cm) high.

Agency Listings and ApprovalsThe listings and approvals below apply to the BG-12 Series pullstations. In some cases, certain modules may not be listed bycertain approval agencies, or listing may be in process. Consultfactory for latest listing status.

• C(UL)US: S711• FM Approved• CSFM: 7150-0075:184• MEA: 67-02-E• Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772;

6,632,108.

Product Line InformationBG-12S: Single-action pull station with pigtail connections, hexlock.BG-12SL: Same as BG-12 with key lock.

BG-12: Dual-action pull station with SPST N/O switch, screwterminal connections, hex lock.BG-12L: Same as BG-12 with key lock.

BG-12LSP: Same as BG-12L with English/Spanish (FIRE/FUEGO) labeling. BG-12LOB: Same as BG-12L with “outdoor use” listing.Includes outdoor listed backbox, and sealing gasket.

BG-12LO: Same as BG-12L with “outdoor use” listing. Doesnot include backbox.

BG-12LA: Same as BG-12L with auxiliary contacts.

BG-12LPS: Dual-action pull station with pre-signal option.BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/FUEGO) labeling.SB-10: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG-12LOB.)

BG12TR: Optional trim ring for semi-flush mounting.17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64”. (Included with hex-lock pull stations.) NOTE: For addressable BG-12LX models, see data sheet DF-52013.

pull station SB-I/O SB-10

Height 5.5 inches(13.97 cm)

5.601 inches(14.23 cm)

5.5 inches(13.97 cm)

Width 4.121 inches(10.47 cm)

4.222 inches(10.72 cm)

4.121 inches(10.47 cm)

Depth 1.39 inches(3.53 cm)

1.439 inches(3.66 cm)

1.375 inches(3.49 cm)

52004dim.tbl

VISTA-32FBCOMMERCIAL PARTITIONED FIRE ANDBURGLARY ALARM CONTROL PANEL

• Hardwired zones– Provides nine style B hardwired

zones

– EOLR supervised for Fire and ULburglary installations

– Supports N.O. or N.C. sensors

– Individually assignable to one ofeight partitions

– Up to 16 two-wire smoke detectorseach on zone one and two (32 total)

• Patented addressable V-Plex pollingloop technology– Supports up to 24 two-wire V-Plex

zones/points

– Global polling technology forfaster processing

– Supervised by panel

– Individually assignable to partitions,notification circuit (bell) output oraux relay

– 4,000 ft. capability without the useof shielded cable

– Extender/Isolation bus modules

– Two-wire smoke detectorzone/group expansion moduleadds two or four zones

– Eight zone – Class A and Bextender module

– Eight zone – Class B extendermodule

– One zone supervised contactmonitor module

• UL Listed wireless expansion– Supports up to 32 wireless zones/

points using 5881ENHC or5883H Receiver

– Supervised by control forcheck-in signals

– Tamper protection for transmitters

– Individually assignable up toeight partitions

– Supports wireless smoke detectors

• Event reporting

• Local printer for access orVISTA related event

• Up to four doors using VistaKeyV-Plex Access Control

• Stored events for one call retrieval

• Communication– Panel operation during download

– Split/Dual Reporting

Applications

The VISTA-32FB control is well suitedfor a variety of applications as anintegrated fire and burglary control.Some of the applications supported are:medical and professional buildings,churches or synagogues, officebuildings, schools, strip malls,residences and factory or warehouseenvironments.

Installation

The VISTA-32FB alarm system hasbeen designed to mount both quicklyand easily. It meets all applicablerequirements for UL commercial fireand burglary installations.

ADDITIONAL FEATURES

Agency Listings

Features

• Plug-in design with minimal intrusion into the back box

• Tamper-resistant construction

• Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela

• Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185

• Horn rated at 88+ dBA at 16 volts

• Rotary switch for horn tone and three volume selections

• Universal mounting plate for wall units

• Mounting plate shorting spring checks wiring continuity before device installation

• Electrically Compatible with legacy SpectrAlert devices

• Compatible with MDL sync module

• Listed for ceiling or wall mounting

The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement.

Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults.

To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed.

Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections.

Indoor Selectable-Output Horns, Strobes, andHorn Strobes forWall Applications

SpectrAlert® Advance audible visible notification products

are rich with features guaranteed to cut installation times

and maximize profits.

MEA452-05-E3023572

7125-1653:186 (indoor strobes)7125-1653:188 (horn strobes,

chime strobes)7135-1653:189 (horns, chimes)

S4011 (chimes, horn strobes, horns)S5512 (strobes)

AVDS00601

SpectrAlert Advance SpecificationsArchitect/Engineer SpecificationsGeneralSpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185.

StrobeThe strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.

Horn Strobe CombinationThe horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply.

Synchronization ModuleThe module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.

Physical/Electrical SpecificationsStandard Operating Temperature 32°F to 120°F (0°C to 49°C)Humidity Range 10 to 93% non-condensingStrobe Flash Rate 1 flash per secondNominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1

Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)Input Terminal Wire Gauge 12 to 18 AWGWall-Mount Dimensions (including lens) 5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D)Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D)Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9˝ L × 5.0˝ W × 2.2˝ D (151 mm L × 128 mm W × 56 mm D)Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS)

5.7˝ L × 4.8˝ W × 0.35˝ D (145 mm L × 122 mm W × 9 mm D)

Notes:1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs.2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd.

AVDS00601

Horn and Horn Strobe Output (dBA)

Switch Position Sound Pattern dB

8–17.5 Volts

16–33Volts

24-Volt NominalReverberant Anechoic

DC FWR DC FWR DC FWR DC FWR1 Temporal High 78 78 84 84 88 88 99 982 Temporal Medium 74 74 80 80 86 86 96 963 Temporal Low 71 73 76 76 83 80 94 894 Non-Temporal High 82 82 88 88 93 92 100 1005 Non-Temporal Medium 78 78 85 85 90 90 98 986 Non-Temporal Low 75 75 81 81 88 84 96 927† Coded High 82 82 88 88 93 92 101 1018† Coded Medium 78 78 85 85 90 90 97 989† Coded Low 75 75 81 81 88 85 96 92

†Settings 7, 8, and 9 are not available on 2-wire horn strobes.

UL Max. Strobe Current Draw (mA RMS)

Candela8–17.5 Volts 16–33 VoltsDC FWR DC FWR

Standard Candela Range

15 123 128 66 7115/75 142 148 77 8130 NA NA 94 9675 NA NA 158 15395 NA NA 181 176110 NA NA 202 195115 NA NA 210 205

HighCandela Range

135 NA NA 228 207150 NA NA 246 220177 NA NA 281 251185 NA NA 286 258

UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd)

DC Input8–17.5 Volts 16–33 Volts15 15/75 15 15/75 30 75 95 110 115

Temporal High 137 147 79 90 107 176 194 212 218Temporal Medium 132 144 69 80 97 157 182 201 210Temporal Low 132 143 66 77 93 154 179 198 207Non-Temporal High 141 152 91 100 116 176 201 221 229Non-Temporal Medium 133 145 75 85 102 163 187 207 216Non-Temporal Low 131 144 68 79 96 156 182 201 210FWR InputTemporal High 136 155 88 97 112 168 190 210 218Temporal Medium 129 152 78 88 103 160 184 202 206Temporal Low 129 151 76 86 101 160 184 194 201Non-Temporal High 142 161 103 112 126 181 203 221 229Non-Temporal Medium 134 155 85 95 110 166 189 208 216Non-Temporal Low 132 154 80 90 105 161 184 202 211

UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd)

DC Input16–33 Volts

FWR Input16–33 Volts

135 150 177 185 135 150 177 185Temporal High 245 259 290 297 Temporal High 215 231 258 265Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258Temporal Low 232 251 282 292 Temporal Low 207 221 248 256Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262

UL Max. Horn Current Draw (mA RMS)

Sound Pattern dB8–17.5 Volts 16–33 VoltsDC FWR DC FWR

Temporal High 57 55 69 75Temporal Medium 44 49 58 69Temporal Low 38 44 44 48Non-temporal High 57 56 69 75Non-temporal Medium 42 50 60 69Non-temporal Low 41 44 50 50Coded High 57 55 69 75Coded Medium 44 51 56 69Coded Low 40 46 52 50

UL Current Draw Data

Horn Tones and Sound Output Data

3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495

©2012 System Sensor.Product specifications subject to change without notice. Visit systemsensor.com

for current product information, including the latest version of this data sheet.AVDS00601 • 3/12

SpectrAlert Advance Dimensions

Model DescriptionWall Horn StrobesP2R*† 2-Wire Horn Strobe, Standard cd‡, RedP2RH* 2-Wire Horn Strobe, High cd, RedP2W* 2-Wire Horn Strobe, Standard cd, WhiteP2WH* 2-Wire Horn Strobe, High cd, WhiteP4R* 4-Wire Horn Strobe, Standard cd, RedP4RH 4-Wire Horn Strobe, High cd, RedP4W 4-Wire Horn Strobe, Standard cd, WhiteWall StrobesSR*† Strobe, Standard cd, RedSRH*† Strobe, High cd, RedSW* Strobe, Standard cd, WhiteSWH* Strobe, High cd, White

SpectrAlert Advance Ordering Information

Notes:* Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P.† Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP.‡ “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185

candela settings.

4.7˝

5.6˝

6.8˝Dia.

2.5˝

2.5˝ 2.23˝5.05˝

5.98˝

7.1˝Dia.

2.25˝

5.1˝

2.0˝

5.7˝

7.1˝Dia.

2.0˝

Wall-mount horn strobes Wall back box skirt

Model DescriptionHornsHR Horn, RedHW Horn, WhiteAccessoriesBBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White TR-HS Trim Ring, Wall, RedTRW-HS Trim Ring, Wall White