Product Features
• Rated for R-22 & R-410a• Cleanable, mold-resistant silver-liner interior surface• UV resistant materials• Fiberglass removed from the air stream• Superior air flow from sides or end of plenum• Easily removable top panel with locking air seal for UV light• Easily installed safety drain pan• Pitched drain pan elevates coil from the condensate• Top left and right refrigerant drain connections• Factory or field installed thermal expansion valve• Aluminum or rifled, copper tube option available• Enhanced aluminum fins• Heavy aluminum end plates vs. galvanized steel• Pressure tested to 500 PSI• Fits furnaces 17” to 23” wide for easy attic installation• Plenum coil combines an adjustable inlet adapter, cooling coil, and supply plenum
into one east install
Safety drain pan has international mechanical code. Council Approval6.2020
ASLB, ASFM, ASKMAll - In - One Plenum
3/4” FPT Primary drain connection3/4” Slip Secondary drain connection
3/8” Refrigerant liquid lineRefrigerant suction line:
1.5 to 3.0 Tons - 3/4”3.5 to 5.0 Tons - 7/8”
Optional galvanized steel cabinets
Cabinet Dimensions
ModelHeight
AWidth
BLength
COpening Height
DOpening Width
EASLT 18.25” 20.25” 26.25” 13.00” to 18.00” 16.00” to 20.25”ASLB 18.25” 20.25” 34.375” 13.00” to 18.00” 16.00” to 20.25”ASLL 18.25” 20.25” 40.375” 13.00” to 18.00” 16.00” to 20.25”ASFM 22.25” 20.25” 34.375” 17.00” to 21.00” 16.00” to 20.25”ASFL 22.25” 20.25” 40.375” 17.00” to 21.00” 16.00” to 20.25”ASKM 26.25” 20.25” 34.375” 21.00” to 23.00” 16.00” to 20.25”ASKL 26.25” 20.25” 40.375” 21.00” to 23.00” 16.00” to 20.25”
Specifications may change without notice
Sturdy Safety Auxilary drain pan exact fit for AllStyle Plenum CoilsSeamless one piece 3/4” FPT drain connection
Mounting brackets are integral to the drain pan
CB
D A
E
20 1/4"18 1/4"-26 1/4"
26 1/4"-40 3/8"
Horizontal PlenumBlower Housing
Cabinet Dimensions
ModelHeight
AWidth
BLength
CEPL 17.00” 17.00” 20.75”EPM 19.00” 19.00” 24.00”EPK 19.00” 19.00” 24.00”Specifications may change without notice
• Plenum coils may be installed with an AllStyle blower housing or with a gas furnace• Optional electric heat 3kW - 20kW• Blower housing has optional ECM motors
Electrical Specifications
Model kW BTUHMCA
CKT 1MCA
CKT 2MCA
CKT 3MOP
CKT 1MOP
CKT 2MOP
CKT 3EPL/EPM 2 - 3 3 10,200 17 0 N/A 20 0 N/AEPL/EPM 2 - 5 4.8 16,300 27 0 N/A 30 0 N/AEPL/EPM 2 - 6 6 20,400 33 0 N/A 40 0 N/AEPL/EPM 2 - 8 7.5 25,600 41 0 N/A 50 0 N/AEPL/EPM 2 - 10 9.6 32,700 52 0 N/A 60 0 N/AEPL/EPM 3 - 6 6 20,400 35 0 N/A 40 0 N/AEPL/EPM 3 - 8 7.5 25,600 43 0 N/A 50 0 N/AEPL/EPM 3 - 10 9.6 32,700 54 0 N/A 60 0 N/AEPL/EPM 3 - 15 14.4 49,100 54 25 N/A 60 30 N/A
EPM 4 - 8 7.5 25,600 44 0 N/A 50 0 N/AEPM 4 - 10 9.6 32,700 55 0 N/A 60 0 N/AEPM 4 - 15 14.4 49,100 55 25 N/A 60 30 N/AEPM 4 - 20 19.2 65,500 55 50 N/A 60 50 N/AEPK 5 - 10 9.6 32,700 56 0 N/A 60 0 N/AEPK 5 - 15 14.4 49,100 56 25 N/A 60 30 N/AEPK 5 - 20 19.2 65,500 56 50 N/A 60 60 N/A
Refer to applicable electrical code for correct wire and over current sizingDe-rate BTUH heating capacity 25% for 208/230 volt application
15 & 20 kW units come with factory installed circuit breakers
Blower Performance
Model SpeedExternal Static Pressure
0.01 0.02 0.03 0.04
EPL/EPM 2DHigh 1160 1100 1050 960Low 1040 990 950 870
EPL/EPM 3DHigh 1380 1330 1240 1160Low 1275 1225 1130 1020
EPM 4DHigh 1740 1650 1550 1400Low 1680 1540 1430 1305
EPL/EPM 2DHigh 1170 1110 1060 970Low 1050 995 960 880
EPL/EPM 3DHigh 1390 1340 1250 1170Low 1280 1230 1140 1030
EPM 4DHigh 1750 1660 1560 1410Low 1690 1565 1430 1315
EPK 5DHigh 2160 2000 1900 1800Low 2050 1910 1805 1710
Product specifications may change without notice