horizontal post-tensioned connections for precast · pdf fileshear walls supporting...

Download Horizontal Post-Tensioned Connections for Precast · PDF fileShear walls supporting hollow-core floor slabs were ... design example is included to ... Typical North American horizontal

If you can't read please download the document

Upload: doankhuong

Post on 06-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • o

    ~ PRECAST I PRESTRESSEO

    CONCRETE INSTI TUTE

    Horizontal Post-Tensioned Connections for Precast Concrete Loadbearing Shear Wall Panels

    64

    Robin L. Hutchinson, P. Eng. Structural Engineer Crosier Kilgour & Partners Winnipeg. Manitoba. Canada

    Sami H. Rizkalla, Ph.D. Professor

    Civil Engineering Department University of Manitoba

    Winnipeg. Manitoba, Canada

    Mike Lau, Ph.D., P. Eng. Engineering Manager Con-Force Structures Limited Winnipeg, Manitoba, Canada

    Scott Heuvel, P. Eng. Principal

    ARC+CADD Architectural CAD Services and Structural

    Engineering Winnipeg. Manitoba, Canada

    This paper presents the results of nine prototype specimens tested to investigate the behavior and capacity of post-tensioned horizontal connections typically used for precast loadbearing shear wall panels subjected to monotonic shear loading. Shear walls supporting hollow-core floor slabs were included. Two different levels of load normal to the connection were used to simulate the effects of gravity and permanent loading conditions. Test results were used to refine and calibrate rational mathematical models developed to predict the maximum shear capacity and the nominal shear strength of the connection. Various failure mechanisms are presented and discussed. A numerical design example is included to show the application of the proposed mathematical model.

    Precast load bearing shear wall panels are used exten-sively for high rise building construction, due to the high quality control that can be achieved with off-site fabrication, the reduction of construction time and, con-sequently. reduction in cost. In addition, precast concrete construction is seldom interrupted by adverse weather con-ditions.

    Precast concrete medium and high rise buildings nor-mally consist of precast concrete loadbearing shear wall panels arranged in both the longitudinal and transverse directions of the building to resist lateral loads, as shown in Fig. I. The major difference between the longitudinal and transverse shear walls is mainly the type of horizontal con-

    PCI JOURNAL

  • ~ LONGITUDINAL ~ v.1ND LOAD

    . J~.-::::;::::;-~ LONGI TUDIN AL > STAIR WELL

    TRANSVERSE v.1ND LOAD

    SHEAR WALLS

    HOLLOW-CORE SLABS

    TRANSVERSE INTERIOR SHEAR WALLS

    Fig. 1. Loadbearing shear wall panel system.

    nection. Transverse shear walls are normally used to support the hollow-core slab of the floor system, whereas the longitudinal shear walls run paral-lel to the hollow-core slab and do not include the hollow-core slab at their connection, as shown in Fig. 2.

    HOllOW-CORE SLAB

    The connections between the panels are extremely important. A well designed simple connection normally minimizes construction time, requires minimal false work and maintains the overall integrity of the structure.

    A recent innovative technique,

    LONGITUDIN AL SHEAR WALL PANEL

    QR'fPACK

    Fig. 2. Horizontal connections for longitudinal and transverse shear walls.

    November-December 1991

    utilized in the construction of horizon-tal connections for load bearing shear wall panels, is the use of vertical post tensioning tendons. The strands pass through galvanized ducts from the top panel to the base of the structu re . While the panels are temporarily braced, the gap between panels, which is necessary for alignment purposes, is packed with dry pack. After the erec-tion of several stories, the tendons are posttensioned, the ducts are grouted and the temporary braces are removed.

    Until now, the posttensioned hori zontal connection, with or without a hollow-core slab, has not been ade-quately examined so as to gain a thorough understanding of its shear behavior under the various limit states. Also, the available literature on the subject is not directly applicable to this type of connection.

    RESEARCH SIGNIFICANCE

    The primary objective of this research is to investigate the behavior of post-tensioned connections for pre-cast concrete load bearing shear wall panels subjected to monotonic shear loading conditions. Connections of shear wall panels supporting the hol-

    TRANSVERSE INTERIOR SHEAR WALL PANEL

    DETAILS IN nGURE 3

    HOLLOW-CORE SLAB

    65

  • DRYPACK i ;;;; 4

    CAST IN PLACE

    CONCRETE FILL

    i ;;;; 3

    CONTlNUOUS

    BEARING PAD i ;;;; f

    PRE;OASl' IN'fERIOR - ~EAA WALL PANEL

    HOLLOW..,CORE SLAB

    i :::: 2

    PAPER OR PLASTlC DAM

    CONCRETE FILL - BETWEEN HOLLOW-CORE

    i = 5

    Fig. 3. Typical North American horizontal jOint with hollow-core slab.

    low -core slab were included. Two load levels normal to the connection were considered to simulate the grav-ity and pennanent loads. The research includes development of rational mathematical models proposed to pre-dict the behavior and capacity of these connections at various limit states. The maximum shear capacity and the nominal shear strength based on the proposed mathematical models com-pared favorably with the measured values.

    BACKGROUND Horizontal connections are typically

    reinforced with a combination of con-tinuity bars and mechanical shear con-nectors. In a previous study conducted at the University of Manitoba,1 it was found that the shear capacity of the horizontal connection may be pre-dicted as the sum of the contributions from the friction resistance of the con-crete interfaces, the dowel action of the continuity bars and the shear resis-tance of the mechanical shear connec-tors. To improve the shear capacity of this type of connection, some fabrica-tors introduced the use of multiple shear keys along the horizontal portion

    66

    of the joint surface of the panel. The presence of these shear keys has been shown to enhance the shear capacity in comparison to the plain surface connection. 2

    Several tests have been conducted in Europe to detemline the shear capacity of horizontal connections supporting a hollow-core slab. However, the details of the European connections differ from those used in North American practice. and their results are not directly applicable.

    The results of two investigations4.~ related to the behavior of connections used in North American practice were significantly different and no effort was made to separate the contribution of the various components of the con-nections to the shear strength of the connections.

    Fig. 3 shows a typical North Ameri-can type horizontal connection sup-porting a hollow-core slab. The major-ity of tests conducted for this type of connection investigated the vertical load carrying capacity. It was found that the total applied vertical stress is distributed to the various components of the connection according to their relative stiffness, as shown in Fig. 4. The total vertical stress nonnal to the

    connection, a n' is distributed to the bearing area of the hollow-core slab in contact with the dry pack, Column I, all ]' and the bearing area of the con-crete fill between the hollow-core slabs, Column 2, crn2, using the fol-lowing expressions:

    crnl = (2h, + b,) crn / (2b, + b2k,/k,)

    (I.)

    where k, and k2 are the equivalent spring constants of Columns I and 2, respectively. These constants can be detennined using the thickness, t;, and the elastic modulus, Ej , for the individ-ual components of the connection as follows:

    t k2 = =---:-:::-

    I'/; / E;

    i = 1, ... ,4

    i =4,5

    where the different components are designated:

    i = I for bearing pad i = 2 for hollow-core slab i = 3 for concrete fill in the cores

    of the hollow-core slab i = 4 for drypack i = 5 for concrete fill between

    hollow-core slabs

    EXPERIMENTAL PROGRAM

    Nine full scale specimens were tested in this experimental program.' The first two groups of specimens were designed to simulate the trans-verse interior shear wall connections supporting the hollow-core floor slabs. The third group was designed to simu-late the horizontal connection of the longitudinal shear walls used for the elevator shafts and stairwells. For each category, the presence of post-tension-ing was investigated and two levels of load normal to the connection were considered to simulate the effects of gravity and permanent loading condi-tions.

    In this paper, the first digit of the specimen mark, given in Tables I and 2, represents the specimen number.

    PCI JOURNAL \

  • ~ DEAD LOAD

    COLUMN S 1:

    HOLLOW-CORE

    SLAB PORTION

    COLUMN 2:

    CONCRETIE FlLL PORTION

    DISTRIBUTION OF

    VERTICAL LOAD

    L

    [n this investigation:

    b, = b, = 50 mm

    A"h = L x l b, = 2 [ 50 x 1200 ] = 120000 mm'

    A". = L x b, = 50 x 1200 = 60000 mm'

    A.h =2[50xl webJ = 2 [ 50 x ( 5x40 + 2x50 ) ] = 30000 mm'

    Note: 1 mm = 0.039 in.

    Fig. 4. Distribution of vertical load and dimensions of typical horizontal connection with hollow-core slab. (Note: 1 mm = 0.039 in.)

    Table 1. Material properties. Table 2. Experimental program and test resulls.

    Cylinder compressive strength Load normal Maximum Nominal shear

    Wall panel Concrete Tensile strength Joint Specimen to connection load strength

    mark Specimen concrete fill Drypack of concrete fill

    type (MPa) (kN) (kN)

    mark (MPa) (M Pa) (MPa) (MPa) HD IH04 4 550 535

    IH04 40.90 55.70 13.70 4.5 2HD8 8 905 750

    2HD8 4 1.30 45.10 13.40 4.0 3HD8 8 885 675

    3HD8 39.70 56. 10 14.70 4.5

    HP 4HP4 4 704 660 4HP4 34.10 52.30 15.60 4.5 5HP8 8 957 6S0 5HP8 38.80 4 1. 10 14.30 3.8 6HP8 8 947 8S0 6HPS 37.60 53.30 12.70 4.4

    7PD4 3S. 10 9.70 11.40 - PD 7P04 4 690 680

    SPD8 46.20 9.70 15.20 - 8PD8 8 1160 11 30 9PD8 37.80 11.50 13.80 -