hormann - steel folding doors
TRANSCRIPT
Industrial Folding Doors and Fire Station Folding DoorsTechnical Manual: Issue 01.06.2009
2 Technical Manual: Industrial Folding Doors 06.2009
Reprinting, (even in excerpts) requires our express approval. All rights reserved. All dimensions in mm. Subject to design changes.
Technical Manual: Industrial Folding Doors 06.2009 3
Contents
Topic Page
Door selection guide 4
Folding door FSN/FAW (fi nger trap protection) 5
Steel folding door FSN, standard profi le•
Aluminium folding door FAW, with thermal breaks•
FSN/FAW design examples 6
FSN/FAW/FPU/FMI – fl oor details 7
Head details for FSN/FAW, fi tting to the wall, 90° opening, view I – I (see page 5) 8
Head details for FSN/FAW, fi tting in the opening, 90° opening, view I – I (see page 5) 9
Wicket door FSN/FAW 10
Divided traffi c leaf FSN/FAW 11
Folding door FPU/FMI, double-skinned 12
FPU with PUR insulation•
FMI with mineral wool insulation•
Ventilation slots FPU/FMI 13
Head details for FPU/FMI, fi tting to the wall, 90° opening, view D – D (see page 12) 14
Head details for FPU/FMI, fi tting in the opening, 90° opening, view D – D (see page 12) 15
Glazings FPU 16
Glazings FMI 17
Wicket door FPU/FMI 18
Divided traffi c leaf FPU/FMI 19
Sideroom FSN/FAW, view A – A (see page 5) 20
Sideroom FSN/FAW, fi tting to the wall, no passage loss, 90° 21
Sideroom FSN/FAW, fi tting to the wall, no passage loss, 180° 22
Sideroom PU/FMI, view A – A (see page 12) 23
Sideroom FPU/FMI, fi tting to the wall, no passage loss, 90° 24
Sideroom FPU/FMI, fi tting to the wall, no passage loss, 180° 25
Choice of folding arrangements/passage width for 3 and 5-leaf doors, FSN/FAW/FPU/FMI 26
Choice of folding arrangements/passage width for 3 to 12-leaf doors, FSN/FAW/FPU/FMI 27
FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 0:2 or 2:0 28
FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 2:2 29
Rain canopy/headroom, opening angle 90°, FSN/FAW/FPU/FMI 30
Rain canopy/headroom, opening angle 180°, FSN/FAW/FPU/FMI 31
Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid 32
Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid 33
Notes 34
4 Technical Manual: Industrial Folding Doors 06.2009
Door Selection Guide
Door typeDepth
approx. 60 mmVersion Sheet thickness/
surface Example leaf infi ll Finger trap protection [KS]
Aluminium diecast hinges, painted black
Thermal insulation value U
Acoustic value R’υ,w,B
4000 x 4000 4000 x 4000
FSN Standard steel profi le
Steel profi le1.5
Sheet steel 1.5 mm
Glazing types between
3 – 36 mm (*)
KS AdjustableFitted on front side
Between 3.5 W/m2 K and
3.7 W/m2 K
Approx. 24 – 28 dB/(A)
FAWAluminium profi le
With thermal breaks
Aluminium profi le2 – 2.5
Insulated glass 26 – 36 mm
PU panel 26 mmKS Adjustable
Fitted on front side
Between 2.0 W/m2 K and
2.3 W/m2 KApprox. 28 dB/(A)
FPU double-skinned
Polyurethane sandwich panel
Stucco-textured or smooth
1.0
Polyurethane(*) KS Surface-
mounted
Between 1.5 W/m2 K and
1.8 W/m2 KApprox. 22 dB/(A)
FMI double-skinned
Mineral wool sandwich panel
Smooth 1.5
(1.75)
Mineral wool (*) KS Surface-
mounted
Between 1.6 W/m2 K and
1.9 W/m2 KApprox. 24 dB/(A)
Glazing types, see the price list *Fire station folding door with folding arrangement 2:2 (see pages 32 – 33)
Size range for manually operated doors
RA
M h
eigh
t
6000
5000
4500
4000
3500
3000
2500
App
rox.
35
00
4000
App
rox.
52
00
App
rox.
80
00
App
rox.
14
000
RAM width
Size range for power-driven doors
RA
M h
eigh
t
6000
5000
4500
4000
3500
3000
2500
App
rox.
35
00
4000
App
rox.
52
00
App
rox.
56
00
App
rox.
80
00
App
rox.
14
000
RAM width
Fully glazed Fire station FPU FMI FSN FAWMax. RAM
4000 x 4000Max. RAM
5200 x 5000Leaf width max. 1400
Leaf width max. 1400
Leaf width max. 1400
Leaf width max. 1300
Technical Manual: Industrial Folding Doors 06.2009 5
Steel Folding Door FSN (Standard Profi le) with Finger Trap ProtectionAluminium Folding Door FAW (with thermal breaks) with Finger Trap ProtectionFolding door, 3-leaf version
FAW: View A – A1x trap protection, see page 20
FAW: View B – B2x trap protection
FSN: View A – A1x trap protection
FSN: View B – B2x trap protection
Elastic trap protection profi les on the vertical leaf edges ensure accident-free operation and also reduce noise.
Fitting to the wall
Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.
Note:Do plaster and screed work after door fi tting.• Folding arrangements and clear passage dimensions, see pages 26 – 27.• With/without ventilation slots•
RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =
LDB (90°)
LDB (180°)
LB
RAM = LB + 160
EXTERIOR
Folding arrangement 1:2
Traffi c leaf
Tubular guide railTrack roller
Intermediate, adjustable aluminium diecast hinge
FFL
Surface-mounted espagnolette lock with loop handle
Surface-mounted
espagnolette lock, prepared
for profi le cylinder
with lever handle set
View I – ISee pages 8 – 9
6 Technical Manual: Industrial Folding Doors 06.2009
FSN/FAW Design Examples
FSN/FAW (max. RAM of the door) FSN
FSN: View K – K FAW: View K – K
Smooth sheet steel Single pane Insulated pane Special infi ll Insulated glass Insulated glass or PU panel
Base area View M – M Base area View N – NView M – M Ventilation slots View N – N Lockable ventilation slots
Max
. 600
0
Min. 1.5 mm
Max. 6 mm
26 mm or 36 mm
Min. 18 mm to max. 36 mm
Min. 26 mm to
max. 36 mm
Max
. 125
0
K
K
M
M
Min
. 300
– m
ax. 6
00
N
N
Min
. 300
– m
ax. 6
00
Min
. 300
– m
ax. 6
00
Min
. 300
– m
ax. 6
00
Optionally with sliding cover on door interior
Max
. 237
5
Max
. 300
0
Max
. 400
0
Max
. 500
0
Fully
gla
zed
(real
gla
ss)
Max
. 400
0
PU panelMax. 26 mm
Technical Manual: Industrial Folding Doors 06.2009 7
FSN/FAW/FPU/FMI – Floor Details
Special version with threshold for e.g. fi re station folding doors
15
94
26
130
150
Version without threshold
15
INTERIOR EXTERIOR
FFL
L 120 x 80 x 8
Recess 130 x 150Leave free until after fi tting
FFL
On-site internalwater run-off
INTERIOR EXTERIOR
8 Technical Manual: Industrial Folding Doors 06.2009
Head Details for FSN/FAWFitting to the Wall, 90° OpeningView I – I (see page 5)
Sideroom overview, see pages 20 – 2290° headroom overview, see page 30180° headroom overview, see page 31
External fi tting Internal fi tting
135
150
100
26
1550
30 x 68 x 50
20
150
1550
100
135
20
30 x 68 x 50
INTERIOR EXTERIOR
LH =
LD
H
RA
M =
LH
+ 1
06
FFL
Min
. 95
Min
. 60
On-site recess
LH
INTERIOR EXTERIOR
RA
M =
LH
+ 8
0
LDH
= L
H –
26
FFL
Min
. 60
Min
. 95
On-site recess
On-site internal water run-off
Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•
RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
Technical Manual: Industrial Folding Doors 06.2009 9
Head Details for FSN/FAWFitting in the Opening, 90° OpeningView I – I (see page 5)
Sideroom overview, see pages 20 – 2290° headroom overview, see page 30180° headroom overview, see page 31
External fi tting Internal fi tting
150
135
30 x 68 x 50
26
5015
100
15
15
150
135
30 x 68 x 50
26
5015
100
15
15
Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•
RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
INTERIOR EXTERIORLDH
= L
H -
(20
+ 60
+ 1
5)
LH
Min. 60
RA
M =
LH
+ 2
6 –
15
FFL
Min. 60
On-site recess
LH
FFL
Min. 60
INTERIOR EXTERIOR
RA
M =
LH
– 1
5
LDH
= L
H -
(26
+ 20
+ 6
0 +
15)
Min. 60
On-site internal water run-off
On-site recess
10 Technical Manual: Industrial Folding Doors 06.2009
Wicket Door FSN/FAW
Wicket door – View FSN/FAW bottom section height
30
60
30
110110
Note:The wicket door is adjusted to match the appearance of the door version.
LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
LDB (opened by 180°)
Backset 40
FFL
LDH
max
. 250
0
Exterior rain canopy
70 =
rail
60
90 =
rail
80
FFL
1050
from
FFL
Wic
ket d
oor h
eigh
t(n
ote
horiz
onta
l rai
l div
isio
n fo
r the
doo
r lea
f!)
2-piece aluminium hinge, black, screwed
Plastic lever handle set, prepared for profi le cylinder, black
A wicket door must be provided for • folding doors without a traffi c leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4, etc. and without a second entrance.An outward-opening escape door may also be required by the authorities.•
Technical Manual: Industrial Folding Doors 06.2009 11
Divided Traffi c Leaf FSN/FAW
Folding door, 3-leaf version, divided traffi c leaf
Detail
FFL Top edge of fi nished fl oor level =
Detail
Traf
fi c le
af h
eigh
t max
. 200
0
Track roller Tubular guide rail
1050
from
FFL
Surface-mounted espagnolette lock with
loop handle
Surface-mounted espagnolette lock,
prepared for profi le cylinder, with lever
handle set
FFL
Divided traffi c leaves (lock leaves) do not have an obstructive threshold rail as with wicket doors.• They are recommended for door heights above 3500 mm and in windy areas (with manual operation).• They also reduce loss of heat.• Divided traffi c leaves enable a larger passage width and barely impair the overall appearance of the door.•
12 Technical Manual: Industrial Folding Doors 06.2009
Steel Folding Door FPU/FMI, Double-SkinnedFPU with PUR InsulationFMI with Mineral Wool Insulation
Folding door, 4-leaf version
View A – A1x trap protection, see page 23
View B – B2x trap protection
View C – C1x trap protection
View D – DSee pages 14 – 15
Elastic trap protection profi les on the vertical leaf edges ensure accident-free operation and also reduce noise.
Fitting to the wall
80
Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.
Note:Do plaster and screed work after door fi tting.• Folding arrangements and clear passage dimensions, see • pages 26 – 27.Without ventilation slots• With ventilation slots with/without sliding cover•
RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =
A A W W C C
Surface-mounted espagnolette lock with loop handle
Surface-mounted espagnolette lock, prepared for profi le cylinder, with lever handle set
FFL
D
D
Tubular guide rail
Aluminium diecast hinge
1050
from
FFL
Track roller
RAM = LB + 160LB
LDB (180°)
Traffi c leaf
Door leaf stayLDB (90°)
Folding arrangement 1:3EXTERIOR
FPU: Door leaf with PUR insulation approx. 60 mm thick (textured on both sides or smooth sheet steel)FMI: Door leaf with mineral wool insulation approx. 60 mm thick (1.50 mm thick smooth sheet steel on both sides)
Door leaf, guide rail and frame hot galvanized and wet primer-coated.Finger trap protection consisting of a hollow rubber profi le between the individual door leaves and side frame.Top lip seal, bottom brush seal.
Technical Manual: Industrial Folding Doors 06.2009 13
Ventilation Slots FPU/FMI
1 ventilation slot group 12 cm2 28 ventilation slots (example) 112 cm2Ventilation slots
Two-side
80
50
30
Exterior ventilation slots Interior sliding cover
Min
. 80
Optionally with sliding cover on
door interior
Min
. 80
Min. 180 Min. 180
Min. 830without glazing
Free ventilation cross section: 3 ventilation slots form one group = 12 cm2, several groups can be arranged next to or on top of each other. Interior sliding cover possible.
14 Technical Manual: Industrial Folding Doors 06.2009
Head Details for FPU/FMIFitting to the Wall, 90° View D – D (see page 12)
Sideroom overview, see pages 23 – 2590° headroom overview, see page 30180° headroom overview, see page 31
External fi tting Internal fi tting
30 x 68 x 50
85 x 60
135
15
26
10050
60
150
1520
85 x 60
30 x 68 x 50
15
26
100
50
135
2015
150
With insulation Without
insulation
Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•
RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
LH =
LD
H
RA
M =
LH
+ 1
06
FFL
Insulation
Min
. 95
Min
. 60
INTERIOR EXTERIOR
On-site recess
LH
Insulation
RA
M =
LH
+ 8
0
LDH
= L
H -
26
FFL
Min
. 60
Min
. 95
On-site internal water run-off
INTERIOR EXTERIOR
On-site recess
Technical Manual: Industrial Folding Doors 06.2009 15
Head Details for FPU/FMIFitting in the Opening, 90° Opening View D – D (see page 12)
Sideroom overview, see pages 23 – 2590° headroom overview, see page 30180° headroom overview, see page 31
External fi tting Internal fi tting
30 x 68 x 50
135
15
1515
26
10050
150
85 x 60
30 x 68 x 50
15 15
15
26
100 50
135
150
85 x 60
With insulation Without
insulation
Doors on the weather side are preferably fi tted externally!• Threshold required as a guide.• 3 and 4-leaf doors also without a threshold on request• On-site internal water run-off required.•
RAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
LH
Insulation
FFL
RA
M =
LH
– 1
5
LDH
= L
H -
121
On-site internal water run-off
INTERIOR EXTERIOR
On-site recess
Min. 60 Min. 60
LDH
= L
H –
95LH
RA
M =
LH
+ 1
1
FFL
Insulation
INTERIOR EXTERIOR
On-site recess
Min. 60Min. 60
16 Technical Manual: Industrial Folding Doors 06.2009
Glazings FPU
Standard Special sizeSingle pane Insulated paneView E – E View F – F
a
a
473523573
773
a a
773
Arrangement of glazing in the partial surface
aa aa
a
a
2000
370
a
Divided traffi c leaf
Leaf section A =Min. 1300 to H = 3000• Min. 1400 to H = 3500• Min. 1500 to H = 4000• Min. 1600 to H = 4500• Min. 1700 to H = 5000•
Black glazing frame as a clamping profi le with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.
a = • min. surrounding area 180
Min
. 125
0
Max. 6
Glazing frame in rounded version, arrangement of glazing in the partial surfacePlastic as standard, metal on request• Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including • clear Duratec acrylic double pane or double-moulded pane 20 mmOther single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site.• Special sizes available up to max. 1250 mm high.•
Min
. 208
Max. 26
Min
. 208
Min
. 208
Technical Manual: Industrial Folding Doors 06.2009 17
Glazings FMI
Standard Special sizeSingle paneView G – G
a
a
473523573
773
a a
773
Arrangement of glazing in the entire surfaceInsulated pane
View H – H
aa
2000
370
Divided traffi c leaf
Black glazing frame as a clamping profi le with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.
a = • min. surrounding area 180
Min
. 108
Min
. 30
0
Min
. 108
min
. 108
Min
. 108
Max. 26
Max. 6
Min
. 125
0
Glazing frame in rounded version, arrangement of glazing in the entire surfacePlastic as standard, metal on request• Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including • clear Duratec acrylic double pane or double-moulded pane 20 mm.Other single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site.• Special sizes available up to max. 1250 mm high.•
18 Technical Manual: Industrial Folding Doors 06.2009
Wicket Door FPU/FMI
A wicket door with threshold must be provided for • folding doors without a traffi c leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4 etc. and without a second entrance (on request also without a threshold for type FMI with folding arrangments 1:2, 2:1, 2:2). An outward-opening escape door may also be required by the authorities.• With • PUR doors a wicket door can only be included from a door height of 3500 mm, and should usually be fi tted in the door leaf without glazing cut-out.
Wicket door view FPUBottom section height 175
FMIBottom section height 95
40
Note:The wicket door is adjusted to match the appearance of the door version.
LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
Wic
ket d
oor h
eigh
t
FFL
1050
from
FFL
2-piece aluminium hinge, black, screwed
Plastic lever handle set, prepared for profi le cylinder, black
Bot
tom
sec
tion
heig
ht
LDH
max
. 250
0
FFL
LDH
max
. 250
0
FFL
Exterior rain canopy
EPDM seal
Black aluminium edge
Black aluminium edge
EPDM seal
EPDM sealBlack aluminium edge
Backset 65
Min. 175Min. 175 LDB (opened by 180°)
Technical Manual: Industrial Folding Doors 06.2009 19
Divided Traffi c Leaf FPU/FMI
Folding door, 3-leaf version, divided traffi c leaf
Detail
FFL Top edge of fi nished fl oor level =
Divided traffi c leaves • (lock leaves) do not have an obstructive threshold rail as with wicket doors.They are recommended for door heights above 3500 mm and in windy areas (with manual operation).• They also reduce loss of heat.• Divided traffi c leaves enable a larger passage width and barely impair the overall appearance of the door.•
Traf
fi c le
af h
eigh
t max
. 200
0
Track roller Tubular guide rail
1050
from
FFL
Surface-mounted espagnolette lock with
loop handle
FFL
Surface-mounted espagnolette lock,
prepared for profi le cylinder, with lever
handle set
Detail
20 Technical Manual: Industrial Folding Doors 06.2009
Sideroom FSN/FAWView A – A (see page 5)
Fitting to the wall Fitting to the wallStandard/normal fi xing Side fi xing
85 x 60
90
10 20
7010
8585 x 60
Fitting in the opening Fitting to the wallSide fi xing Free passage width with 180° opening angle
10
85 x 6050
10 85
85 x 60
Head details overview, see page 8 – 9 RAM Overall frame dimension =LB Clear width =
RAM = LB + 220
LBMin. 120
LB
RAM = LB + 120
Min
. 60
LB
RAM = LB – 20
Min
. 60
Min
. 60
RAM = LB + 160
Min. 60
LB
Technical Manual: Industrial Folding Doors 06.2009 21
Sideroom FSN/FAWFitting to the WallNo Passage Loss
Folding arrangement 2:1
340 250
Folding arrangement 4:3
560 470
Folding arrangement 5:6 (not possible with FAW)
690 780
Head details overview, see pages 8 – 9Folding arrangement overview, see pages 26 – 27
RAM Overall frame dimension =LB Clear width =
RAM = LB + 590LB
RAM = LB + 1470
LB
RAM = LB + 1030
LB
22 Technical Manual: Industrial Folding Doors 06.2009
Sideroom FSN/FAWFitting to the WallNo Passage Loss
Folding arrangement 2:1
275
365
120 120
135
135
Folding arrangement 4:3
605
495
120 120
135
135
Folding arrangement 5:5 (not possible with FAW)
715
120 120
135
135
Head details overview, see pages 8 – 9Folding arrangement overview, see pages 26 – 27
RAM Overall frame dimension =LB Clear width =
RAM = LB + 240
LB
RAM = LB + 240
LB
RAM = LB + 240
LB
Technical Manual: Industrial Folding Doors 06.2009 23
Sideroom FPU/FMIView A – A (see page 12)
Fitting to the wall Fitting to the wallStandard/normal fi xing Side fi xing
90
10 20
85 x 60
7010
8585 x 60
Fitting in the opening Fitting to the wallSide fi xing Free passage width with 180° opening angle
10
85 x 60
10 85
70
85 x 60
Head details overview, see pages 14 – 15 RAM Overall frame dimension =LB Clear width =
LB
RAM = LB + 120
Min
. 60
LB
RAM = LB – 20
Min
. 60
Min
. 60
LB
RAM = LB + 260
Min. 140
LB
RAM = LB + 160
Min. 60
24 Technical Manual: Industrial Folding Doors 06.2009
Sideroom FPU/FMIFitting to the WallNo Passage Loss
Folding arrangement 2:1
340 250
Folding arrangement 4:3
560 470
Folding arrangement 5:6
690 780
Head details overview, see pages 14 – 15Folding arrangement overview, see pages 26 – 27
RAM Overall frame dimension =LB Clear width =
RAM = LB + 590LB
RAM = LB + 1470LB
RAM = LB + 1030
LB
Technical Manual: Industrial Folding Doors 06.2009 25
Sideroom FPU/FMIFitting to the WallNo Passage Loss
Folding arrangement 2:1
275
365
140 140
135
135
Folding arrangement 4:3
495
605
140 140
135
135
Folding arrangement 5:6
140 140
135
715
135
Head details overview, see pages 14 – 15Folding arrangement overview, see pages 26 – 27
RAM Overall frame dimension =LB Clear width =
RAM = LB + 280
LB
RAM = LB + 280
LB
RAM = LB + 280
LB
26 Technical Manual: Industrial Folding Doors 06.2009
Folding Arrangement/Passage Widthfor 3 and 5-Leaf DoorsFSN/FAW/FPU/FMI
Folding arrangements are read from the opening side (fi tting side) from left to right. 3 and 4-leaf doors with folding arrangements 3:0, 0:3, 1:3, 3:1, 4:0 and 0:4 without threshold and with internal fi tting with guide piece in the fl oor.
FAWFSN
FPUFMI
➀ Folding doors without a traffi c leaf: A wicket door is required if there is no second entrance.
RAM - 590 RAM - 240 RAM - 280 1:2
RAM - 590 RAM - 240 RAM - 280 2:1
RAM - 565 RAM - 215 RAM - 200 3:00
RAM - 565 RAM - 215 RAM - 200 00:3
RAM - 720 RAM - 240 RAM - 280 1:3
RAM - 720 RAM - 240 RAM - 280 3:1
RAM - 680 RAM - 240 RAM - 280 2:2 ➀
RAM - 655 RAM - 215 RAM - 200 00:4 ➀
RAM - 655 RAM - 215 RAM - 200 4:00 ➀
RAM - 810 RAM - 240 RAM - 280 2:3
RAM - 810 RAM - 240 RAM - 280 3:2
RAM - 810 RAM - 240 RAM - 280 4:1
RAM - 785 RAM - 215 RAM - 200 00:5
Technical Manual: Industrial Folding Doors 06.2009 27
Folding Arrangement/Passage Widthfor 6 to 12-Leaf DoorsFSN/FAW/FPU/FMI
Folding arrangements are read from the opening side (fi tting side) from left to right.
FAWFSN
FPUFMI
➀ Folding doors without a traffi c leaf: A wicket door is required if there is no second entrance.➁ Not possible with FAW
RAM - 940 RAM - 240 RAM - 280 3:3
RAM - 940 RAM - 240 RAM - 280 3:3
RAM - 900 RAM - 240 RAM - 280 2:4 ➀
RAM - 1030 RAM - 240 RAM - 280 3:4
RAM - 1030 RAM - 240 RAM - 280 4:3
RAM - 1120 RAM - 240 RAM - 280 4:4 ➀
RAM - 1250 RAM - 240 RAM - 280 4:5 ➁
RAM - 1250 RAM - 240 RAM - 280 5:4 ➁
RAM - 1380 RAM - 240 RAM - 280 5:5 ➁
RAM - 1380 RAM - 240 RAM - 280 5:5 ➁
RAM - 1470 — — 6:5 ➁
RAM - 1470 — — 5:6 ➁
RAM - 1560 — — 6:6 ➀➁
28 Technical Manual: Industrial Folding Doors 06.2009
FSN/FAW/FPU/FMIOperator Type AFT B900 – Folding Arrangement 0:2 or 2:0
Folding door with operator
80
330
170
80
RAM Overall frame dimension =LH Clear height =LB Clear width =LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
RA
M
Operator
LH
LDH
= L
H –
app
rox.
95
Operator
FFL
RAM
Folding arrangement 2:0
Opening angle 90°
LDB = LB – approx. 475 (near operator arm)
LB
Approx. 360
Approx. 370
Approx. 110
Technical Manual: Industrial Folding Doors 06.2009 29
FSN/FAW/FPU/FMIOperator Type AFT B900 – Folding Arrangement 2:2
Folding door with operator
8080
170
330
330
80170
80
RAM Overall frame dimension =LH Clear height =LB Clear width =LDB Clear passage width =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
FFL
Operator
LH
LDH
= L
H –
app
rox.
95
Operator Operator
1050
RA
M
RAM
Folding arrangement 2:2
Opening angle 90°
LDB = LB – approx. 740 (near operator arm)
LB
Approx. 110Approx. 110
Approx. 360
Approx. 370
Approx. 360
Approx. 370
30 Technical Manual: Industrial Folding Doors 06.2009
Rain Canopies/HeadroomOpening Angle 90°FSN/FAW/FPU/FMI
Canopy 1 Canopy 2
8012016
519
0
60
12016
519
0FSN/FPU/FMI: Door with or without operator
Cover 3
12021
027029
5
295
270
210
120
FAW: Door with operator
Rain canopy length: RAM + approx. 100 mm
Type of fi tting Headroom [mm]Without rain canopy With rain canopy
To the interior wall 95 -To the exterior wall 95 200/200 ➁In the opening - on request
In the opening ➂ 160 on requestFire station folding door 170 -
➁ Applies to FSN folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2➂ Applies to FAW folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2
Approx. 170
INTERIOR EXTERIOR
➂INTERIOR EXTERIOR
Approx. 270
INTERIOR EXTERIOR
Approx. 270
➁
INTERIOR EXTERIOR
Operator
Operator arm
Approx. 435
Approx. 270
Technical Manual: Industrial Folding Doors 06.2009 31
Rain Canopies/HeadroomOpening Angle 180°FSN/FAW/FPU/FMI
Canopy 4
11521
0
27029
5
Canopy 5
80
210
290315
Rain canopy length: RAM + approx. 300 mm
Type of fi tting Headroom [mm]Without rain canopy With rain canopy
On the wall 240 310/330 ➄In the opening 160 -
➄ Applies to folding arrangements: 1:4/4:1/2:4/4:2/1:5/5:1/2:5/5:2/3:4/4:3/4:4/3:5/5:3/4:5/5:4/5:5
INTERIOR EXTERIOR
Approx. 450
INTERIOR EXTERIOR
Approx. 660
➄
32 Technical Manual: Industrial Folding Doors 06.2009
Fire Station Folding Doors FSN/FAW/FPU/FMIFast Opening via a MechanicalOpening Aid
Folding arrangement 2:215
20 Without traffi c leaf (locking leaf).Can only be opened from inside (second entrance required).
Fitting to the wall
60 x 85
Mechanical opening aid arranged on the door interior!
Fitting in the opening
RAM Overall frame dimension =LB Clear width =LDB Clear passage width =FFL Top edge of fi nished fl oor level =
DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.
FFL
Connecting lead 230 V (3 x 1.5)
On-site connecting lead
Push button
App
rox.
190
0
Grip handle
Energy storing device Snap locking Energy storing device
Lifting magnet 230 V
Grip handlePull cord
Folding arrangement 2:2, opening angle 90°
LDB min. 3500
LB = min 4360
RAM = LB – 20
EXTERIOR
INTERIOR
Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90°.Release via pull cord. Supplemented with lifting magnet. On-site connecting lead.The quick release can be operated on the left or right (right arrangement shown).The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button.Group switching possible.
RAM = LB + 680 (min. 4180)
LB = LDB (min. 3500)
EXTERIOR
INTERIOR
Space requirement = LB + 800 (min. 4300)
Folding arrangement 2:2, opening angle 90°Min. 170
Min. 850
Technical Manual: Industrial Folding Doors 06.2009 33
Fire Station Folding Doors FAW/FPU/FMI/FSNFast Opening via a MechanicalOpening Aid
Fitting to the wall Fitting in the opening
15
1525
140
60x8
560
x85
15
15
1525
120
60x85
60x85
Detail ASeepage 30 120
10
60x8560x85FAWRAM Overall frame dimension =LH Clear height =LDH Clear passage height =FFL Top edge of fi nished fl oor level =
FSN with insulation
FSN without insulation
DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.
EXTERIOR INTERIOR
FFL
LH =
cle
ar p
assa
ge h
eigh
t 350
0 or
400
0
RA
M =
LH
+ 1
40
Min
. 60
Min
. 60
Min
. 60
FFL
EXTERIOR INTERIOR
RA
M =
LH
-15
LDH
= L
H –
(160
+ 1
5)
LH =
367
5 or
417
5 w
ith F
AWLH
= 3
670
or 4
170
with
FP
U-F
MI-
FSN
Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90°.Release via pull cord. Supplemented with lifting magnet. On-site connecting lead.The quick release can be operated on the left or right (right arrangement shown).The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button.Group switching possible.
34 Technical Manual: Industrial Folding Doors 06.2009
Notes
Technical Manual: Industrial Folding Doors 06.2009 35
Notes
Issu
e 06
.200
9 /
Prin
t da
te 0
9.20
09 /
HF
8578
7 en
/ P
.1.5
75
Hörmann KG Werne Hörmann Genk NV, Belgium Hörmann Beijing, China Hörmann LLC, Montgomery IL, USA
Hörmann KG Amshausen Hörmann KG Antriebstechnik Hörmann KG Brandis Hörmann KG Brockhagen
Hörmann KG Dissen Hörmann KG Eckelhausen Hörmann KG Freisen Hörmann KG Ichtershausen
Hörmann: Quality without Compromise
Hörmann is the only manufacturer worldwide that offers you
a complete range of all major building products from one source.
We manufacture in highly-specialized factories using the
latest production technologies.
The close-meshed network of sales and service companies
throughout Europe, and activities in the USA and China,
make Hörmann your strong partner for first-class building
products, offering “Quality without Compromise”.
GARAGE DOORS
OPERATORS
INDUSTRIAL DOORS
LOADING EQUIPMENT
HINGED DOORS
DOOR FRAMES