hospital grade receptacles power ... - steven...

24
Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock Pro Surge & IG Power Quality Panels Power Strips Occupancy Sensors Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Upload: dangdan

Post on 06-Feb-2018

213 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock Pro™

Surge & IG

Power Quality Panels Power Strips

Occupancy Sensors

B-1027C HealthBrochure.qxd 7/11/06 2:02 PM Page 2

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 2: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

● Hospital Grade 15 & 20 Amp Straight& Angle Devices

● HG Power Indication Plugs & Connectors

● 20 Amp Hospital GradePower InterruptingDevices

● 15-60 Amp NEMA & Non-NEMA StraightBlade Devices

● 15-30 Amp NEMA &Non-NEMA Locking Devices

● Infrared, Ultrasonic & Multi-Technology Units● Individual Units Cover 180 & 360 Degrees,

Up to 2000 Square Feet● Ambient Light Override Feature● Self Contained Units for 120 or 277V Circuits● Ultrasonic & Multi-Technology Units Require

Separate Power Pack● Cage Available for High Abuse Areas

PAGES 19-21

● Available with Infraredand Adaptive Infrared Technologies

● Ambient Light OverrideFeature

● Single Unit Operates On120 or 277V and Can Handle Incandescent orFluorescent Loads

● Single & Dual RelayOptions

● Device Fit StandardSwitch Boxes & UtilizeDecora Wallplates

PAGE 19

● Available Technologies Include Infrared, Ultrasonic & Multi-Technology

● Individual Units Cover110 and 360 degrees,up to 2500 square feet

● Ambient Light OverrideFeature

● Ultrasonic & Multi-Technology Units Require Separate Power Pack

● Infrared High-BayVersion Available withSecondary Relay Option

PAGE 21

Hea

lth

Care

Pro

duct

Typ

es

1

Health Care Product Types

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

● Protection at Facility Service Entrance● Advanced Diagnostics for Monitoring Trends

in Surge Events on LCD Display● Models Available for Generator Transfer

Switch, Panelboard and Dedicated Equipment Applications

PAGES 13 & 14

SURGE PROTECTION SURGE STRIPS SURGE PANELS

FOUR-IN-ONE GFCI SMARTLOCK® PLUGS & CONNECTORS

SWITCH MOUNT CEILING MOUNT WALL MOUNT

● Hospital Grade ● 15-20 Amp Duplex &

Single Configurations● Interlocking

Thermoplastic Nylon Cover & Body

●Permanent "Green Dot"Marked on Face

●Nickel-Plated Brass Strap with Integral

Ground Contacts●Back & Side Wired

Ground Termination

● Hospital Grade ● 15 Amp version has a

nickel plated steel strap● 20 Amp version has a

nickel plated brass strapand a 1 piece mounting strap/grounding system

● Mechanical Safety Shutters

● Interlocking Thermoplastic Cover & Body

● Approved for EmergencyCircuits and Pediatric/Psychiatric Care Areas

● Hospital Grade ● 15-20 Amp

Configurations● 100,000 Hr.

Green LED Power Status Indicator

● Permanent "Green Dot" Lens

● Suitable for Critical Care Areas and Emergency Circuits

● Nickel-Plated BrassStrap with Integral Ground Contacts

● Full Illuminated Face Also Available

HOSPITAL SPEC TAMPER-RESISTANT POWER INDICATION

8300-R 8300-SGI 8300-PLW

74120-7M3

● Hospital Grade ● 15-20 Amp Configurations● Hospital, Surge and IG Versions●Thermoplastic Nylon Face and Body● Universal Mounting

8490-IGG

ODS0D-IDW ODW12-M0D

● Hospital Grade ● 15-20 Amp Duplex

Configurations● Back & Side Wired ● LED Status Indicator● Prevents Reset if

Protective Function is Compromised

● Prevents Reset in Case of Line-Load Reverse Wiring

● Meets New UL GFCI Requirements, Effective 20068598-HGW

● Hospital Grade15-20 Amp Duplex & Single Configurations

●Surge & IG Versions● Audible and Visual

Protection Status Alarms

● Back & Side Wired● Thermoplastic Nylon

Cover & Body

PAGE 8

8280-IGB

8215-C

8319-C

● Six Outlet, 6’ Cord withHospital Grade Plug & Receptacles

● No Switch Provided – Power is Always ON toAvoid Accidental Shutdown

● Three Mode Protection with Leakage Current Below 100 Microamps

● Tamper Resistant Receptacles

PAGES 11 & 22

5300-HT2

ODC0S-I1W

Occupancy Sensors

PAGE 5PAGE 5 PAGE 5

PAGES 6 & 7 PAGES 9 & 10 PAGES 11 & 12

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 3

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 3: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

2

Hospital G

rade Device Testing

Hospital Grade Testing

Cord Pull TestThe cord must remain securely fastened afterstraight pulls of 30 pounds, and rotating pulls (in a 3-inch circle) of 10 pounds for two hours.“Displacement of conductors, insulation, andouter jacket of the flexible cord AWG 18 SVTshall not exceed 1/32 inch.There shall be nocuts, rips, or tears in cord insulation.”

Heavy-duty cord stress is typical abuse forindustrial plugs and connectors. Levitonincreases the weight in the straight cord pulltest to 175 lbs. with AWG 14 ST and in therotating pull test to 20 lbs., ensuring positivestrain relief under industrial conditions.

Mechanical Drop Test A sample wired plug or connector is suspended horizontally by its attached cord,and released so that it impacts a hard woodsurface 45 inches below the point of suspension--repeated for 1300 cycles. “Thereshall be no breakage, deformation, or otherdamage which would interfere with the func-tioning of the device.”

Impact Test A wired plug or connector is subjected toimpact from a 10 lb. weight repeatedlydropped from a height of 18 inches. “Thereshall be no breakage, deformation or othereffect that may interfere with the function ofthe device.” Plugs and connectors are sub-jected to severe impacts in industrial settings.Therefore, Leviton exceeds the UL require-ment by dropping the weight from a height of36 inches.

500 lb. Crush TestA wired plug or connector is placed betweentwo steel plates and subjected to a force whichis steadily increased to 500 pounds. “Thereshall be no breakage, deformation or othereffect that may interfere with the function of thedevice.” Leviton knows that in real industrialenvironments, plugs and connectors arecrushed by forces exceeding 500 lbs. Weperform the crush test with a force of 2500 lbs.to ensure that our devices withstand the reallyheavy hits on the job.

Abrupt Removal of Plug TestA steel-bodied test plug with brass blades is inserted into the receptacle. A 10-poundweight dropped from at least 24 inchesyanks the plug out of the receptacle.Thistest is done eight times with the receptaclerotated into different positions to create thegreatest stress on its face and contact. Afterthis, the grounding contact must retain afour ounce, 0.184” diameter grounding pin,with the receptacle face down, for oneminute.There shall be no breakage of thereceptacle that interferes with the receptaclefunction or the integrity of the enclosure.Thereceptacle shall maintain the grounding pathintegrity through the receptacle.

Ground Pin Retention TestThe grounding contact of the receptacle isconditioned by 20 insertions with a .204”oversized pin. After conditioning, a 0.184”diameter pin shall be inserted in the ground-ing contact which shall be capable of sup-porting at least four ounces for one minute.

4oz.+

Power Blade Retention TestA test plug with oversized blades of .075” isinserted into the current-carrying opening ofthe receptacle for 20 conditioning cycles.After the conditioning cycles, the contactshall be capable of supporting for oneminute 11/2 lbs. secured to a single .055”thick solid steel blade without holes.

1.5 lb.Assembly Security TestA force of 100 pounds is applied through the slots to the base of the receptacle while the yokeis supported at its screw mounting positions. There must be no cracking of base or permanentdeformation of yoke.

In addition...Leviton Hospital Grade receptacles undergo these demanding tests:

• Strength of insulating base• Ground contact temperature• Impact test• Ground Contact Resistance• Terminal Strength Test• Resistance of Ground• Fault current• Gripping

• Overload• Temperature• Dielectric withstand• Insulation resistance• Assembly security• Receptacle ground contact• Horsepower

Testing For Hospital Grade Listing Of Plugs, Connectors, and Receptacles Includes:

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 4

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 4: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Wiring Devices1. What are the requirements for

receptacles in General Care Patient Bed Locations?� NEC Article 517.18 (B)

� Must be hospital grade and have a permanent means of identification.

� Must have a minimum of four receptacle outlets.

2. What are the requirements for receptacles in Pediatric Locations?� NEC Article 517.18 (C)

� Must be hospital grade and have a permanent means of identification.

� Must be listed as Tamper Resistant

3. What are the requirements for receptacles in Critical Care Patient Bed locations?� NEC Article 517.19 (B)(1)

� Must be identified as hospital grade with a permanent indicator.

� Must have a minimum of six receptacle outlets.

4. True or False: Receptacles supplied by the emergency power system shall have distinctive color or marking as to be readily identifiable.True.� NEC Article 517.41 (E)

and NFPA 99, 3-5.2.2.4 � Requires receptacles on

the emergency circuit to be readily identified.

� Device color or wall plate ID.

5. What are the requirements for receptacles and fixed equipment installed in wet locations?� NEC Article 517.20 (A)

� All receptacles and fixed equipment within the area of the wet location shall have ground-fault circuit-interrupter protection for personnelif interruption under fault conditions can be tolerated. If servedby an isolated power system, ground fault circuit interrupterprotection is not required.

� GFCI protection is not required for receptacles installed in critical care areas where the toilet and basin are installed within the patient room.

6.What are the testing and maintenance requirements for electrical receptacles in health care facilities?� NFPA 99, Chapter 3-3 Section 3-3.3.3

� Visual integrity, ground continuity, polarity and ground blade retention force.

� Chapter 3-3 Section 3-3.4.2.3

� Testing shall be performed after initial installation, replacement or servicing. Additional testing shall be performed at intervalsdefined by documented performance data.

Exception: Receptacles not listed as hospital grade shall be testing at intervalsnot exceeding 12-months.

Freq

uent

ly A

sked

Que

stio

ns

3

Frequently Asked Questions

Health Care Facilities Code and Application Related Questions

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 5

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 5: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

4

Frequently Asked Q

uestionsFrequently Asked Questions

1. How does a surge protector work? � A Surge Protector, sometimes called

a TVSS (transient voltage surge suppressor); Diverts surge currents away from equipment by creating a low impedance path to ground.

� Typical components include:� MOV: Metal-Oxide

Varistor

� SAD: Silicon Avalanche Diodes

� Gas Tubes

� LCR filters

2. How do surges enter a building?� Surges Enter A System In Two Ways:� Conducted (Directly On Lines Entering

or Leaving A System)

� Radiated (Indirectly Via Electro-magnetic Fields)

3. What is IEEEC62.41?

The Institute of Electrical and Electronic Engineers have developed C62.41 59to provide recommended guidelines on surge exposure levels with respect to location. The standard amplitudes and wave forms are the basis for testing surge receptacles.

4. Does the NEC cover installation of Transient Voltage Surge Suppressors?

� Yes. NEC Article 285 TVSS Protection covers short circuit rating and installation and connection of TVSS or Surge Protection panels.

5. What are the three basic types of occupancy sensor technologies?

� Passive Infrared (PIR) 'Line-of-sight' device that responds to infraredchanges in a workspace.

� Ultrasonic devices transmit ultrasonicfrequencies (32kHz-40kHz) andmonitor workspace changes.'Line-of-sight not required'.

� Multi-Technology single unit that combines PIR and Ultrasonic to controllighting loads in a workspace.

6. Can occupancy sensors save energy and reduce power bills?

� Yes. Since lighting accounts for 50% of the electricity usage in a typical commercial or institutional facility turning those loads off when not required can have a considerable impact on the bottom line.

7. Are adjustments required to make surethe lights do not go off while the workspace is occupied?

� Most commercial grade occupancy sensors are self adjusting. After initial installation the device monitors occupancy patterns and automatically compensates for 'real-time' usage and sets itselfaccordingly.

For the complete line of Power Quality products, request the Power Quality Product Line Bulletin (C-678A).

For the complete line of Occupancy Sensor Products request the Occupancy Sensors Product Guide (G-7164).

For the complete line of Lighting Controls products, request the Lighting Controls Product Catalog (G-6960).

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 6

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 6: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

5

Hos

pita

l Gra

de S

trai

ght

Bla

de R

ecep

tacl

es15A 125V&250V;20A125V&250VHospital Grade 10 YEAR LIMITED

NEMA 5-15R NEMA 5-20R NEMA 6-15R NEMA 6-20R

Back & Side Wired, Self-Grounding

8210-R8300-E 8300-SGI8200-HI 8300-PLW8300-HLI

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 #E13399 #152105 #057

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30�Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

FACE HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD. HOSP. GRD.COLOR DUPLEX SLIM DUPLEX TAMPER DUPLEX DUPLEX DUPLEX SINGLE

DUPLEX RESISTANT ILLUMINATED

Brown 8200 8200-H 8200-SG – 8200-L – 8210Ivory 8200-I 8200-HI 8200-SGI 8200-HLI 8200-LI 8200-PLI 8210-IWhite 8200-W 8200-HW 8200-SGW 8200-HLW 8200-LW 8200-PLW 8210-WGray 8200-G 8200-HG 8200-SGG – 8200-LGY – –Red 8200-R 8200-HR 8200-SGR 8200-HLR 8200-LR 8200-PLR 8210-R

Brown 8300 8300-H 8300-SG – 8300-L – 8310Ivory 8300-I 8300-HI 8300-SGI 8300-HLI 8300-LI 8300-PLI 8310-IWhite 8300-W 8300-HW 8300-SGW 8300-HLW 8300-LW 8300-PLW 8310-WGray 8300-G 8300-HGY 8300-SGG – 8300-LGY – 8310-GRed 8300-R 8300-HR 8300-SGR 8300-HLR 8300-LR 8300-PLR 8310-RBlack 8300-E – – – 8300-LE – –Almond – – – – 8300-LA – –

1.31(33.3 mm)

0.82(20.8 mm) 1.33

(33.7 mm)

1.06(30 mm)

2.38

(60

.3 m

m)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

0.85(21.6 mm)

1.55(39.5 mm)

1.51(38.5 mm)

1.31 (33.3 mm)

1.31 (33.3 mm)

2.77

(70

.4 m

m)

2.76

(70

.0 m

m)

1.18 (29.9 mm)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

2.77

(10

3.2

mm

)

1.38 (33.7 mm)

0.87 (22.1 mm)

1.12 (28.4 mm)

1.21 (38.4 mm)

0.87 (22.1 mm)

1.31 (33.3 mm)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

LEVITON

1.11(28.1 mm)

0.88(22.3 mm)

2.78

(70

.6 m

m)

125V15A

1.53(38.9 mm)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

1.31(33.3 mm)

8200, 8300, 8200-PL,8300-PL, 8400, 8600 8200-H, 8300-H 8200-HL, 8300-HL 8210, 83108200-SG

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

8400

20A 250V, NEMA 6-20R

15A 250V, NEMA 6-15R

FACE HOSP. GRD.COLOR DUPLEX

Brown 8600Ivory 8600-IWhite –Gray –Red –

Brown 8400Ivory 8400-IWhite –Gray –Red –Black –

w/Green LED Power StatusIndicator

8300-L

Midway 302/304 non-magnetic stainlesssteel wallplates provide more coverage ofwall openings to conceal imperfections thatmight occur during sheetrock installation.

w/6” Wire Leads

15A 125V, NEMA 5-15R

20A 125V, NEMA 5-20R

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 7

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 7: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

6

Hospital G

rade Straight Blade Isolated G

round Receptacles15A 125V;20A125V

Hospital Grade10 YEAR LIMITED

NEMA 5-15R NEMA 5-20R

NYLON WALLPLATES 302 STAINLESS STEEL WALLPLATES WEATHER RESISTANCE COVERS DIE-CAST ZINC

ISOLATED GROUND ISOLATED GROUND

80703-IG 80703-RE 80704-IG 80716-I 84004-40 84003-40 84016-40 84005-40 4925-2 4970

FOR ADDITIONAL WALLPLATE OPTIONS SEE IPD 2.05 CATALOG

Back & Side Wired

8200-IGBSplit Circuit Not Available

1254-IGW 8490-IGG 8200-LIG 8210-IG

4-in-1 Side Wired

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 #E13399 #152105 #057

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30�Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

15A 125V, NEMA 5-15R

20A 125V, NEMA 5-20R

EMERGENCY

2.77

(70

.4 m

m)

0.87(22.1 mm)

1.12(28.4 mm) 1.55

(39.5 mm)

1.31(33.3 mm)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

1.31(33.3 mm)

0.82(20.8 mm) 1.33

(33.7 mm)

1.06(30 mm)

2.38

(60

.3 m

m)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

2.77

(10

3.2

mm

)

1.38 (33.7 mm)

0.87 (22.1 mm)

1.12 (28.4 mm)

1.31 (33.3 mm)

3.28

(83

.3 m

m)

4.06

(10

3.2

mm

)

8200-IG, 8300-IG 8210-IG, 8310-IG8200-LIG, 8300-LIG

FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADECOLOR IG DUPLEX IG 4-IN-1 IG 4-IN-1 SURGE IG DUPLEX IG SINGLE

Refer to page 7 for Terminal Accom. & Device Drawings

Brown 8200-IGB – – – –Ivory 8200-IGI 1254-IGI – – –White 8200-IGW 1254-IGW 8480-IGW – –Gray 8200-IGG – 8480-IGG – –Red 8200-IGR – – – –Orange 8200-IG 1254-IG 8480-IG 8200-LIG 8210-IG

Brown 8300-IGB – – – –Ivory 8300-IGI 21254-IGI – – –White 8300-IGW 21254-IGW 8490-IGW – –Gray 8300-IGG – 8490-IGG – –Red 8300-IGR – – – –Orange 8300-IG 21254-IG 8490-IG 8300-LIG 8310-IG

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

w/6” Ground Lead w/6” Ground Lead

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 8

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 8: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Split Circuit Not Available8490-IGG

Split Circuit Not Available8490-R

7

Hos

pita

l Gra

de F

our-

In-O

ne S

trai

ght

Bla

de R

ecep

tacl

es

10 YEAR LIMITED

15A 125V, NEMA 5-15R

20A 125V, NEMA 5-20R

4.50 (114.3 mm) square

3.38 (85.9 mm) 0.68 (17.1 mm)

0.25 (6.4 mm)

3.38

(85

.9 m

m)

1.15 (29.2mm)

4.80 (121.9 mm) square

2.75 (69.8 mm)

3.38 (85.9 mm

1.75 (44.4 mm)

1.73 (43.9 mm)

0.31(7.9 mm)

0.42 (10.7 mm)0.12 (3.2 mm)

3.28

(83

.4 m

m)

3.38

(85

.9 m

m)

2.73

(69

.3 m

m)

4.25

(10

7.9

mm

)

DIMENSIONS APPLY TO ALL FOUR-IN-ONE RECEPTACLES 4254 3254

Four-In-One Adapter Plates Four-In-One Portable Boxes

PLATE ADAPTERCOLOR PLATE

Brown 3254Ivory 3254-IWhite 3254-WGray 3254-GYRed 3254-RBlack 3254-EOrange 3254-ORBlue 3254-BLU

MountsDirectly

Single-Gang

4” Square

4” Octagon

Mountswith

AdapterPlate

411/16”Square

2-Gang

4.50 (114.3 mm) square

3.38 (85.9 mm) square

3.28

(83

.3 m

m)

squ

are

4 knockouts

.90(22.9 mm)

ø 0.66

(16.8)Feed Thru Wire Hole

Portable boxes are not UL Listed.

15A 125V; 20A 125VHospital Grade

NEMA 5-15R NEMA 5-20R

1254-HW 1254-IG

Accepts #16/3 AWG Type SJ to #12/3 AWGType SO COPPER Only.

Side Wired

For clamping and performance data refer

to page 8.

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 #E13399 #152105 #057

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30�Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

BOX PORTABLECOLOR BOX

Ivory 4254-IGray 4254-GYBlack 4254-EOrange 4254-ORBlue 4254-BLUYellow 4254-Y

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADECOLOR IG IG, SURGE SURGE

Brown 1254-H – – –Ivory 1254-HI 1254-IGI 8480-IGI 8480-IWhite 1254-HW 1254-IGW 8480-IGW 8480-WGray – – 8480-IGG –Red 1254-HR – – 8480-RBlack – – – –Orange – 1254-IG 8480-IG –Blue – – 8480-IGB –

Brown 21254-H – – –Ivory 21254-HI 21254-IGI 8490-IGI 8490-IWhite 21254-HW 21254-IGW 8490-IGW 8490-WGray 21254-HGY – 8490-IGG –Red 21254-HR – – 8490-RBlack – – – –Orange – 21254-IG 8490-IG –Blue – – 8490-IGB –

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 9

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 9: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

8

Hospital G

rade AC D

ecora Surge Receptacles15A 125V; 20A 125V

Hospital Grade10 YEAR LIMITED

NEMA 5-15R NEMA 5-20R

1.47 (37.3 mm)

2.70

(68

.6 m

m)

3.81

(96

.8 m

m)

3.28

(83

.3 m

m)

1.70 (43.2 mm)

SURGE RECEPTACLES

Back & Side Wired

8380 8280-IGO 8281-IGI Back View8381-GY

15A 125V, NEMA 5-15R

20A 125V, NEMA 5-20R

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 – #152105 #057

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30� Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

OPERATING MAXIMUM MAXIMUM MAXIMUM EMI-RFI NOISEFREQUENCY CONTINUOUS SINGLE-PULSE SINGLE-PULSE REJECTION

OPERATING (10x1000µs) (8x20µs) @ 50 OhmsVOLTAGE (MCOV) Joules L-N/L-G/N-G 500K - 30MHz

50, 60Hz 150V rms 720 24kA/12kA/12kA -30dB

PERFORMANCE DATAUL1449 SUPPRESSED

VOLTAGE RATINGS (SVR) Assigned at 6" lead length with 6kV/500A

impulse in accordance with UL1449 (2nd Ed.)

400/400/400Vpk

CLAMPING PERFORMANCE

FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADECOLOR SURGE, DUPLEX SURGE, SINGLE IG, SURGE, DUPLEX IG, SURGE, SINGLE

Brown 8280 – – –Ivory 8280-I – 8280-IGI 8281-IGIWhite 8280-W – 8280-IGW 8281-IGWGray – – 8280-IGG –Red 8280-R – – –Blue 8280-B – 8280-IGB –Black – – – –Orange – – 8280-IGO 8281-IGOAlmond – – 8280-IGA 8281-IGA

Brown 8380 8381 – –Ivory 8380-I 8381-I 8380-IGI 8381-IGIWhite 8380-W – 8380-IGW 8381-IGWGray 8380-GY 8381-GY 8380-IGG –Red 8380-R 8381-R 8380-IGR –Black – – – –Blue 8380-B – 8380-IGB 8381-IGBOrange – – 8380-IGO 8381-IGOAlmond – – – –

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

Indicator Light,Audible Alarm

Indicator Light,Audible Alarm

Indicator Light,Audible Alarm

Indicator Light,Audible Alarm

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 10

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 10: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

SCREWLESS NYLON 302 STAINLESS STEELSNAP-ON WALLPLATES WALLPLATES WALLPLATES

15A 125V, NEMA 5-15R

80301-I 80309-I 80401-NE 80409-NE 84409-40 84411-40

• Meets or Exceeds UL, 2006 Requirements

• Smart Lock® GFCI Prevents Reset in Case of Line-Load Reverse Wiring

• Greater Protection Against Loss of Ground Fault Protection Due toSurges, Abuse and Overvoltages

• Device Prevents Reset If Its Protective Function Has Been Compromised

FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSP. GRD.SMARTLOCK®

COLOR DUPLEX DUPLEX IG DUPLEX DUPLEX w/LED - GFCI DUPLEXTAMPER-RESISTANT Self-Grounding Does Not Apply w/ LOCKOUT

Brown – 16262-SG – – 7599-HGIvory 16262-HGI 16262-SGI 16262-IGI 16262-PLI 7599-HGIWhite 16262-HGW 16262-SGW 16262-IGW 16262-PLW 7599-HGWGray 16262-HGG 16262-SGG 16262-IGG – 7599-HGGRed 16262-HGR 16262-SGR 16262-IGR 16262-PLR 7599-HGRBlack – – – – –Blue – – 16262-IGB – –Orange – – 16262-IG – –Almond – – – – 7599-HGALight Almond – – – – 7599-HGT

9

Hos

pita

l Gra

de A

C D

ecor

a Pl

us R

ecep

tacl

es15A 125VHospital Grade 10 YEAR LIMITED

Back & Side Wired, Self-Grounding4.

06 (

103.

2 m

m)

3.81

(96

.8 m

m)

3.28

(83

.3 m

m)

0.88 (22.4 mm)

1.52 (38.7 mm)

1.14 (29.0 mm)

1.31 (33.3 mm)

2.78

(70

.6 m

m)

15A 125VRECEPTACLE

TEST

TEST

TES

T M

EN

SU

EL

TES

T M

ON

THLY

SU

IVE

Z INS

TRU

CTIO

NFO

LLOW

DIR

EC

TION

SRESETRESET

16262 & 16362 SERIES 7599-HG SERIES

NEMA 5-15R

16262-HGR 16262-SGW 16262-IG 16262-PLR 7599-HGR

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 – #152105 #057

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30�Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

Note: This devicemeets UL FedSpec WC-596requirements

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

w/Green LED PowerStatus Indicator

1.7 (43.2 mm)

1.12 (28 mm)

2.7

(68.

6 m

m)

4.21

(10

6.93

mm

)

15A 125VRECEPTACLE

CLASS ALEVITON

GFC

I

CLA

SS

15 AM

P125V

1.53 (38.9 mm)

TEST

TEST

TES

T M

EN

SU

EL

TES

T M

ON

THLY

SU

IVE

Z INS

TRU

CTIO

NFO

LLOW

DIR

EC

TION

SRESETRESET

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 11

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 11: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

20A 125V, NEMA 5-20R

SCREWLESS NYLON 302 STAINLESS STEELSNAP-ON WALLPLATES WALLPLATES WALLPLATES

80301-I 80309-I 80401-NE 80409-NE 84409-40 84411-40

• Meets or Exceeds UL, 2006 Requirements

• SmartLock® GFCI Prevents Reset in Case of Line-Load Reverse Wiring

• Greater Protection Against Loss of Ground Fault Protection Due toSurges, Abuse and Overvoltages

• Device Prevents Reset If Its Protective Function Has Been Compromised

10

Hospital G

rade AC D

ecora Plus Receptacles

10 YEAR LIMITED

15A 125VHospital Grade

NEMA 5-20R

4.06

(10

3.2

mm

)

3.81

(96

.8 m

m)

3.28

(83

.3 m

m)

0.88 (22.4 mm)

1.52 (38.7 mm)

1.14 (29.0 mm)

1.31 (33.3 mm)

2.78

(70

.6 m

m)

15A 125VRECEPTACLE

TEST

TEST

TES

T M

EN

SU

EL

TES

T M

ON

THLY

SU

IVE

Z INS

TRU

CTIO

NFO

LLOW

DIR

EC

TION

SRESETRESET

Back & Side Wired, Self-Grounding

16362-HGI 16362-IG 16362-PLR

MECHANICAL

TERMINAL TERMINAL PRODUCTI.D. ACCOMM. I.D.

Brass, hot

Grounding

White,neutral

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings are permanently

marked on device

#14 - #10 AWGMax 30�Cafter 250 cycles of

overload at200% of

rated current

AC HORSEPOWER RATINGS

15A 125V 15A 250V 20A 125V 20A 250V

.5 1.5 1.0 2.0

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498HG WC-596 C22.2 No. 42

� � #E13399 – #152105 #057

16262 & 16362 SERIES 7899-HG SERIES

7899-HGW

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

FACE HOSPITAL GRADE HOSPITAL GRADE HOSPITAL GRADE HOSP. GRD.SMARTLOCK®

COLOR DUPLEX IG DUPLEX DUPLEX w/LED - GFCI DUPLEX w/ LOCKOUTSelf-Grounding Does Not Apply Meets 2003 UL Requirements

Brown – – – 7899-HGIvory 16362-HGI 16362-IGI 16362-PLI 7899-HGIWhite 16362-HGW 16362-IGW 16362-PLW 7899-HGWGray 16362-HGG 16362-IGG – 7899-HGGRed 16362-HGR 16362-IGR 16362-PLR 7899-HGRBlack – – – –Blue – 16362-IGB – –Orange – 16362-IG – –Almond – – – 7899-HGALightAlmond – – – 7899-HGT

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

1.7 (43.2 mm)

1.12 (28 mm)

2.7

(68.

6 m

m)

4.21

(10

6.93

mm

)

15A 125VRECEPTACLE

CLASS ALEVITON

GFC

I

CLA

SS

20 AM

P125V

1.53 (38.9 mm)

TEST

TEST

TES

T M

EN

SU

EL

TES

T M

ON

THLY

SU

IVE

Z INS

TRU

CTIO

NFO

LLOW

DIR

EC

TION

SRESETRESET

w/Green LED PowerStatus Indicator

Note: This devicemeets UL FedSpec WC-596requirements

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 12

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 12: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

30�C max at fullrated current

after 50 cyclesoverload at150% rated

current for bothAC and DC per

UL 498

11

Hos

pita

l Gra

de S

trai

ght

Bla

de P

lugs

& C

onne

ctor

s, P

ower

Str

ips

15A 125; 20A 125&250VHospital Grade 10 YEAR LIMITED

8315-CT 8315-CAT8319-C

20A 125V, NEMA 5-20P AND 5-20R, 2-P 3-W

20A 250V, NEMA 6-20P AND 6-20R, 2-P 3-W

Ø 1.39 (35.3 mm)

Ø 1.49 (37.9 mm)

2.76

(70

.1 m

m)

Ø 1.53 ( 38.9 mm)

Ø 1.39 ( 35.3 mm)

1.98

(50

.4 m

m)

0.97 (24.7 mm)

1.15 (29.2 mm) dia.

1.05 (26.8 mm)

1.57

(39

.9 m

m)

PLUGS CONNECTORS ANGLE PLUGS

15A 125V, NEMA 5-15P AND 5-15R, 2-P 3-W

NEMA 5-15P NEMA 5-15R NEMA 5-20P` NEMA 5-20R NEMA 6-20P NEMA6-20R

MECHANICAL

TERMINAL TERMINAL PRODUCT CORD GRIPI.D. ACCOMM. I.D. RANGE

Brass, hot

Grounding

White,neutral

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498 Listed WC-596 C22.2 No. 42

� � � #E13393 #LR-406 #057

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings &NEMA I.D.

permanentlymarked on device

#18 - #10AWG

.245" - .700"

TYPE PLUG CONNECTOR ANGLE PLUG

Black & White 8215-C 8219-C –Transparent 8215-CT 8219-CT 8215-CATLighted Transparent 8215-PLC 8219-PLC –

Black & White 8315-C 8319-C –Transparent 8315-CT 8319-CT 8315-CATLighted Transparent 8315-PLC 8319-PLC –

Transparent – – 8415-CAT

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

5300-HT2

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

6-HG,TAMPER-RESISTANT OUTLETS & HOSP. GRADE

LIGHTED TRANSPARENT PLUG

5300-HT2

20A 120V NEMA 5-20 P, Plug & 5-20RReceptacles 2-P 3-W

SURGE SUPPRESSOR PLUG STRIP w/ MULTI-STAGE

PROTECTION

CORD LENGTH

6'(without switch)

5300-HTS

6-HG,TAMPER-RESISTANT OUTLETS & HOSP. GRADE

LIGHTED TRANSPARENT PLUG

5300-HTS (6')5300-H15 (15')

15A 120V NEMA 5-15P & 5-15R

2-P 3-W

SURGE SUPPRESSOR PLUG STRIP w/ MULTI-STAGE

PROTECTION

CORD LENGTHS

6' and 15'(without switch)

See Additional Strips Page 22

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 13

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 13: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

12

Hospital G

rade Plugs & Connectors

15A 125V & 250V;20A 125V & 250VHospital Grade10 YEAR LIMITED

GR

W Y

X

GR

NON-NEMA NON-NEMA

23001-HG 23000-HG23004-HG

20A 125V, Non-NEMA, 2-P 3-W, Grounding UL Listed for "HOSPITAL USE ONLY" applications in non-hazardous areas.

NEMA 5-15P NEMA 5-15R15A 250V, 2-P 3-W, Grounding

20A 125V, 2-P 3-W, Grounding

20A 250V, 2-P 3-W, Grounding

NEMA 6-15P NEMA 6-15R

NEMA 5-20P NEMA 5-20R

NEMA 6-20P NEMA 6-20R

PYTHON PYTHON 23001-HG 23004-HGPLUGS CONNECTORS

1.81

(46

.0 m

m)

1.40 (35.7 mm) 1.50 (38.1 mm)

2.50

(64

.0 m

m)

1.41 (35.7 mm)

1.69 (42.9 mm)

3.63 (92.1 mm

)

1.69 (42.9 mm)

3.25 (82.6 mm

) 2.31 (58.7 m

m)

1.50 (38.1 mm)

8256-V 8259-V 8456-V

PLUGS AND CONNECTORS

TM

84004-40

MECHANICAL

TERMINAL TERMINAL PRODUCT CORD GRIPI.D. ACCOMM. I.D. RANGE

Brass, hot

Grounding

White,neutral

STANDARDS & CERTIFICATIONS

NEMA ANSI UL UL Fed Spec CSA NOMWD-6 C-73 498 Listed WC-596 C22.2 No. 42

� � � #E13393 #LR-406 #057

30�C max at fullrated current

after 50 cyclesoverload at150% rated

current for bothAC and DC per

UL 498

ENVIRONMENTAL

FLAMMABILITY OPERATING TEMP.

Rated V-2 per UL 94 -40�C to 60�C

Ratings &NEMA I.D.

permanentlymarked on device

#18 - #10AWG

.245" - .700"

15A 125V, 2-P 3-W, Grounding

POWER INTERRUPTING LOCKING LOCKING LOCKING 302 NON-NEMADEVICES PLUG CONNECTOR FLUSH RECEPTACLE STAINLESS STEEL

w/ THERMOSET BODY WALLPLATE

Gray & Black 23004-HG 23001-HG 23000-HG

COLOR STRAIGHT BLADE STRAIGHT BLADE NEMAPYTHON PLUG PYTHON CONNECTOR

White 8256-V 8259-V –

White 8656-V 8659-V

White 8356-V 8359-V

White 8456-V 8459-V

ELECTRICAL

DIELECTRIC CURRENT TEMP.VOLTAGE INTERR. RISE

Withstands Full2000V rated

per currentUL 498

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 14

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 14: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Pow

er Q

ualit

y D

evic

es -

Sur

ge P

rote

ctiv

e Pa

nel M

ount

s

13

Panel Mounted Devices74000 & 75000 Series - For Industrial & Commercial Environments

Diagnostic Capabilities:• Monitors the status of each phase

• Display will indicate “Fault”, “Alert”, and “Protection” status.

• Functions include a surge event counter, amplitude measurement, date and time stamping of the event.

• Events are stored and are recallable and downloadable by the user

Normal Operations:• Green indicator lights illuminate when the panel status is OK. A fault condition is indicated when up to 3 indicators are no longer illuminated

• Yellow indicator light will illuminate and audible alarm will sound when one of the fuses in the surge module opens due to surge activity The percentage of protection in that module will flash on the screen (i.e., 75% protection when 1 fuse is open)

• Red indicator light will illuminate and audible alarm will sound when protection level is at 50% or less

• Arrow buttons allow user to view surge event history on each line by scrolling through data

• Information is easily downloadable via RS-232 port using the program “Hyperterminal” that comes standard on any Windows operating software (see instruction sheet for detailed instructions)

74000 & 75000 Series

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

10 YEAR LIMITED

74120-7M3

SPECIFICATIONS & FEATURES74000 & 75000 SERIES

• Provides Seven Mode Protection.• User replaceable modules• Real-time diagnostics monitor power and suppression status for each mode

• Surge magnitude, time, and date is provided for each surge event

• Surge event history downloadable for storage via RS-232 connection

• AC Sine Wave Tracking• Optically isolated dry contacts

• UL 1449 2nd Edition Listed

ENVIRONMENTAL

STORAGE TEMPERATURE-20�C to 85�C

OPERATING TEMPERATURE-10�C to 60�C

STANDARDS & CERTIFICATIONSANSI/IEEE Categories A, B, & C

C-62.41 & C-62.45

UL 1449#E146315

CSA#LR-94773

DESCRIPTION CATALOG NO. VOLTAGE RATING MODULE NO.3ø WYE (4-Wire + Ground)

7-Mode, 3ø WYE, 4-Wire + Ground 74120-7M3 120/208V AC (7) HC120-M407-Mode, 3ø WYE, 4-Wire + Ground 74277-7M3 277/480V AC (7) HC277-M407-Mode, 3ø WYE, 4-Wire + Ground 75120-7M3 120/208V AC (7) HC120-M537-Mode, 3ø WYE, 4-Wire + Ground 75277-7M3 277/480V AC (7) HC277-M53

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 15

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 15: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Panel Mounted Devices74000 & 75000 Series - For Industrial & Commercial Environments

14

Power Q

uality Devices - Surge Protective Panel M

ounts

FaultFault

FaultFault

AlertAlert

AlertAlert

ProtectionProtection

ProtectionProtection

ProtectionProtection

TestTest EnterEnter ResetReset ALARM ALARMAUDIOAUDIO

Line 3Line 3

Line 1Line 1

Line 2Line 2FaultFault

FaultFault

AlertAlert

AlertAlert ProtectionProtection USUSC

N-GN-G

Line 2Line 2

Line 1Line 1

Line 3Line 3

SURGE COUNTERSURGE COUNTERPROTECTION STATUSPROTECTION STATUS

3 PHASE WYE3 PHASE WYE

120/208 VAC 50/60 HZ 120/208 VAC 50/60 HZ

CATALOG NO. 75120-7M3CATALOG NO. 75120-7M3

15.8

(40

1mm

)

8.33 (211.6mm)

7.48 (190mm)

19.71 (500.3mm)

74000 & 75000 SERIES

74000 & 75000 Series

Diagnostic display panel on the 74000 and75000 Series uses LED display to indicate“Fault”, “Alert”, and “Protection” status.

75000 Series modules are designed withfour arrester grade MOV's each rated for80,000 Amps, 8x20us Impulse. Each mod-ule is tested to maximum levels of surgecurrent withstand at an independent labo-ratory.

Large-diameter MOV's, 40mm on 74000Series panels and 53mm on the 75000Series, are individually thermal fused forover-current protection.

CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE6kV/500A (test w/ 8x20us wave) REJECTION

L-N L-G N-G L-N + L-G = “per Phase”

74120-7M3 150V AC 400 400 400 200 200 400 -40 dB(@ 5K-100MHz)

74277-7M3 320V AC 800 800 800 200 200 400 -40 dB(@ 5K-100MHz)

75120-7M3 150V AC 400 400 400 320 320 640 20-40 dB(@ 5K-100MHz)

75277-7M3 320V AC 800 800 800 320 320 640 20-40 dB(@ 5K-100MHz)

10 YEAR LIMITED

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 16

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 16: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

ENVIRONMENTAL

FLAMMABILITY

Pow

er Q

ualit

y D

evic

es -

Sur

ge P

rote

ctiv

e Pa

nel M

ount

s

15

Panel Mounted Devices57000 Series - For Service Entrance or Branch Panels

10 YEAR LIMITED

Replacement Modules for Superior ProtectionThe heart of the Cat. No. 57000 group is the powerful Replacement Module equipped withextremely effective hybrid multi-component suppression circuitry. Six different module variants areavailable to suit a range of commonly available North American AC line-voltage configurations.

57120-M3Type 1

57120-CM3Type 12

STANDARDS & CERTIFICATIONS

SPECIFICATIONS & FEATURES57000 SERIES

• Available with NEMA 12 enclosureFlush mount collar included with most units

• Dry contacts for remote monitoring (NO-C-NC)

• Modular design allows for easy replacement of modules

• Features Sine-Wave Tracking and Redundant Protection

• UL 1449 2nd Edition Listed

STORAGE TEMPERATURE-20�C to 85�C

OPERATING TEMPERATURE-10�C to 60�C

UL 945-VFlame Retardant Thermoplastic

(Front Bezel)

ANSI/IEEE Categories A, B, & CC-62.41 & C-62.45

UL 1449#E146315

NEC200 KAIC Rated per Article 285

CSA#LR-94773

DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.3ø WYE (4-Wire + Ground)

3ø WYE, 4-Wire & Ground 57120-M3 57120-CM3 120/208V AC (3) 120(1) 8120-GN

3ø WYE 7-Mode, Integral 57120-M3S 57120-C3S 120/208V AC (3) 120-M3SDisconnect, 4-Wire & Ground (1) 8120-GN3ø WYE, 4-Wire & Ground 57220-IM3 –– 220/380V AC (3) 220

(1) 8250-GN3ø Delta, 3-Wire & Ground 57240-DM3 – 240V AC (3) 72403ø WYE, 4-Wire & Ground 57277-M3 57277-CM3 277/480V AC (3) 7277

(1) 8320-GN3ø WYE 7-Mode, Integral 57277-M3S 57277-C3S 277/480V AC (3) 7277-M3SDisconnect, 4-Wire & Ground (1) 8320-GN3ø WYE, 4-Wire & Ground 57346-M3 – 346/600V AC (3) 7347

(1) 8385-GN3ø WYE, 4-Wire & Ground 57347-M3S – 347/600V AC (3) 7346

(1) 8385-GN3ø Delta, 3-Wire & Ground 57480-DM3 – 480V AC (3) 74803ø Delta, 3-Wire & Ground 57600-DM3 – 600V AC (3) 7600

57000 Series

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 17

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 17: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Panel Mounted Devices57000 Series - For Service Entrance or Branch Panels

16

Power Q

uality Devices - Surge Protective Panel M

ounts

10 YEAR LIMITED

1.53(38.9 mm) 3.28 (83.3 mm)

4.41

(11

2.0

mm

)

HIGH VOLTAGE

Haute tension

DANGER

5.00" (127.0 mm)

10.31" (261.9 mm)

7.50" (190.5 mm)

3.50

" (8

8.9

mm

)

14.9

" (3

60.4

mm

)

57000 SERIES 57000-M3S 52000-RS

20.0

0 (5

08.0

mm

)

®

16.00 (406.4 mm) 6.80 (172.7 mm)

8.02(203.7 mm)

57000 Series panels Shown with 52000-RS Remote Supervisor, features easy-to-install replaceable modules.

CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE6kV/500A (test w/ 8x20us wave) REJECTION

L-N L-G N-G L-L L-N + L-G = “per Phase”

57120-M3 150V AC 400 800 400 800 150 – 150 -20 to -40 dB57120-CM3 (@ 5K-10MHz)

57120-M3S 150V AC 400 500 400 700 100 100 200 -20 to -40 dB57120-C3S (@ 5K-10MHz)

57220-IM3 250V AC 600 1200 600 1200 150 – 150 -20 to -40 dB(@ 5K-10MHz)

57240-DM3 250V AC – – – 700 -20 to -40 dB(@ 5K-10MHz)

57277-M3 320V AC 800 1800 800 1800 150 – 150 -20 to -40 dB57277-CM3 (@ 5K-10MHz)

57277-M3S 320V AC 900 1000 800 1500 100 100 200 -20 to -40 dB57277-C3S (@ 5K-10MHz)

57346-M3 385V AC 1000 2000 1000 2000 150 – 150 -20 to -40 dB(@ 5K-10MHz)

57347-M3S 390V AC 1000 1000 1000 2000 100 100 200 -20 to -40 dB(@ 5K-10MHz)

57480-DM3 550V AC – – – 1500 -20 to -40 dB(@ 5K-10MHz)

57600-DM3 680V AC – – – 1800 -20 to -40 dB(@ 5K-10MHz)

57000 Series

L-L: 150

L-L: 150

L-L: 150

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 18

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 18: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Remote Supervisor Provides Clear Indication of Protection StatusAll Leviton Panel mounted SPD’s are equipped with real-time diagnostics that indicate protectionstatus. However, when these units are mounted in electrical closets, or other out-of-the-way locations,a diagnostic alert might not be seen or heard for some time.

The 52000-RS Remote Supervisor can relay protection failure or power interruption warnings fromone or more Leviton panel-mounted SPD’s. Warnings are provided by an optically coupled sensor anddata lines comprising up to 5000 feet of #20 or #22 twisted-pair wiring. One Remote Supervisor canmonitor up to six panel-mounted SPD’s. The Remote Supervisor provides both a visual and audiblealert, which can be silenced at the press of a button. The unit is equipped with a test circuit, anddesigned for surface mounting. It draws power from any 120V source through a six-foot line cord.

52000-RS

ENVIRONMENTAL

FLAMMABILITY

Pow

er Q

ualit

y D

evic

es -

Sur

ge P

rote

ctiv

e Pa

nel M

ount

s

17

Panel Mounted Devices52000 Series - For Industrial & Commercial Environments

10 YEAR LIMITED

DESCRIPTION WITHOUT SURGE COUNTER WITH SURGE COUNTER VOLTAGE RATING MODULE NO.

Single Phase, 2-Wire & Ground 52120-M1 – 120V AC (1) 2120(1) 8120-GN

Single Phase, 3-Wire & Ground 52120-M2 52120-CM2 120/240V AC (2) 2120(Home Automation Model) (52120-M2H) (1) 8120-GN3ø WYE, 4-Wire & Ground 52120-M3 52120-CM3 120/208V AC (3) 2120(Without Enclosure) (52120-B3) (1) 8120-GN3ø WYE (International), 52220-IM3 – 220/380V AC (3) 22204-Wire & Ground (1) 8250-GN3ø Delta, 3-Wire & Ground 52240-DM3 – 240V AC (3) 22403ø WYE, 4-Wire & Ground 52277-M3 52277-CM3 277/480V AC (3) 2277

(1) 8320-GN3ø WYE, 4-Wire & Ground 52347-M3 – 347/600V AC (3) 2347

(1) 8385-GN3ø Delta, 3-Wire & Ground 52480-DM3 – 480V AC (3) 2480Split Phase Delta, 52412-DS3 – 120/240V AC (2) 2120 (120V) &4-Wire & Ground (1) 2412 (Hi-Leg)

52000 Series

52120-M3Type 12

52120-CM3Type 12

STANDARDS & CERTIFICATIONS

SPECIFICATIONS & FEATURES52000 SERIES

• Available with NEMA 12 enclosureFlush mount collar included with most units

• Dry contacts for remote monitoring

• Features Sine-Wave Tracking and Redundant Protection

• UL 1449 2nd Edition Listed

STORAGE TEMPERATURE-20�C to 85�C

OPERATING TEMPERATURE-10�C to 60�C

UL 945-VFlame Retardant Thermoplastic

(Front Bezel)

ANSI/IEEE Categories A, B, & CC-62.41 & C-62.45

UL 1449#E146315

NEC200 KAIC Rated per Article 285

CSA#LR-94773

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 19

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 19: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Panel Mounted Devices52000 Series - For Industrial & Commercial Environments

18

Power Q

uality Devices - Surge Protective Panel M

ounts

10 YEAR LIMITED

HIGH VOLTAGE

Haute tension

DANGER

5.00" (127.0 mm)

10.31" (261.9 mm)

7.50" (190.5 mm)

3.50

" (8

8.9

mm

)

14.9

" (3

60.4

mm

)

52000 SERIES 52000-RS

1.53(38.9 mm) 3.28 (83.3 mm)

4.41

(11

2.0

mm

)

52000 Series

CATALOG NO. MCOV UL 1449 (2nd Ed) IMPULSE MAX.SURGE CURRENT in KA NOISE6kV/500A (test w/ 8x20us wave) REJECTION

L-N L-G N-G L-L L-N

52120-M1 150V AC 400 800 400 – 100 -20 to -40 dB(@ 5K-10MHz)

52120-M2 150V AC 400 800 400 800 100 -20 to -40 dB52120-CM2 (@ 5K-10MHz)

52120-M2H 150V AC 400 800 400 800 100 N/A DHC Power Line Carrier Compatible

52120-M3 (B3) 150V AC 400 800 400 800 100 -20 to -40 dB52120-CM3 (@ 5K-10MHz)

52220-IM3 250V AC 600 1200 600 1200 100 -20 to -40 dB(@ 5K-10MHz)

52240-DM3 L-L: 250V AC – – – 600 100 -20 to -40 dB(@ 5K-10MHz)

52277-M3 320V AC 800 1800 800 1800 100 -20 to -40 dB52277-CM3 (@ 5K-10MHz)

52347-M3 420V AC 900 – – 900 100 -20 to -40 dBL-L: 680 (@ 5K-10MHz)

52480-DM3 550V AC – – – 1500 100 -20 to -40 dB(@ 5K-10MHz)

52412-DS3 L-L: 250V AC 400 800 400 800 100 -20 to -40 dB(@ 5K-10MHz)

For answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com/powerquality

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 20

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 20: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Com

mer

cial

Gra

de W

all S

wit

ches

& C

eilin

g-M

ount

Occ

upan

cy S

enso

rs

19

Infrared Occupancy SensorsCommercial Grade Wall Switches & Ceiling-Mount

Commercial Grade Decora® Wall Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)

Commercial Grade Dual-Relay Decora® Wall Switch Infrared Occupancy SensorsAdaptive Dual Relay Occupancy Sensors:Conference Room Mode Both Primary andSecondary Relays respond to AmbientLight Override.

Alternate Setting: Classroom Mode PrimaryRelay only responds to Ambient LightOverride.

Primary Relay:Fluorescent: 1200VA @120V, 2700VA @ 277VIncandescent: 800W @120VSecondary Relay:Fluorescent: 800VA @120V, 1200VA 277VIncandescent: 800W @120V

ODS15-IDWwith 80301-W plate

ODS0D-IDWwith 80301-W plate

COLOR CATALOG NUMBER DESCRIPTION RATING

Ivory ODS15-IDI Fluorescent: 1800VA @ 120V,White ODS15-IDW Adaptive Infrared 4000VA @ 277VGray ODS15-IDG Occupancy Sensors Incandescent: 1800W @ 120VAlmond ODS15-IDA Motor: 1/4 HP @ 120V

COLOR CATALOG NUMBER DESCRIPTION RATING

Ivory ODS0D-IDIWhite ODS0D-IDWGray ODS0D-IDGAlmond ODS0D-IDA

Commercial Grade Decora® Wall Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)

COLOR CATALOG NUMBER DESCRIPTION RATING

Ivory ODS10-IDI Fluorescent: 1200VA @ 120V,White ODS10-IDW Infrared 2700VA @ 277VGray ODS10-IDG Occupancy Sensors Incandescent: 800W @ 120VAlmond ODS10-IDA Motor: 1/4 HP @ 120V

Commercial Grade Self-Contained Ceiling-Mount Occupancy Sensors

COLOR CATALOG NUMBER DESCRIPTION COVERAGE RATING

White ODC0S-I1W Self-Contained Ceiling-Mount 360°, 530 sq. ft. Incandescent: 1000W @ 120V(formerly 16786-120) Infrared Occupancy Sensor Fluorescent/Inductive:

and Switching Relay 1000VA @ 120V For 60Hz AC only.1HP@120V AC

White ODC0S-I2W Self-Contained Ceiling-Mount 360°, 530 sq. ft. Incandescent: 1000W @ 220V Infrared Occupancy Sensor Fluorescent/Inductive:and Switching Relay 500VA @ 220V For 50Hz AC only.

White ODC0S-I7W Self-Contained Ceiling-Mount 360°, 530 sq. ft. Fluorescent/Inductive:(formerly 16786-277) Infrared Occupancy Sensor 2700VA @ 277V For 60Hz AC only.

and Switching Relay

White ODCCG-000 Protective Cage – –

ODC0S-I1W

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

For the complete line of Occupancy Sensor Products request the Occupancy Sensors Product Guide (G-7164).

For the complete line of Lighting Controls products, request the Lighting Controls Product Catalog (G-6960).

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 21

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 21: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Occupancy SensorsCommercial Grade Multi-Tech and Ultrasonic

20

Comm

ercial Grade Ceiling-M

ount Occupancy Sensors

ODC20-M0W

Multi-Technology Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digitalself-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect LevitonOccupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).

Commercial Grade Ceiling-Mount Occupancy Sensors

COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY

White ODC05-M0W Multi-Tech Ceiling-Mount 180°, 500 sq. ft. 40kHzOccupancy SensorMulti-Tech Ceiling-Mount

White ODC05-MRW Occupancy Sensor with Ambient 180°, 500 sq. ft. 40kHzLight Override & Secondary Relay

White ODC10-M0W Multi-Tech Ceiling-Mount 180°, 1000 sq. ft. 32kHzOccupancy SensorMulti-Tech Ceiling-Mount

White ODC10-MRW Occupancy Sensor with Ambient 180°, 1000 sq. ft. 32kHzLight Override & Secondary Relay

White ODC20-M0W Multi-Tech Ceiling-Mount 360°, 2000 sq. ft. 32kHzOccupancy SensorMulti-Tech Ceiling-Mount

White ODC20-MRW Occupancy Sensor with Ambient 360°, 2000 sq. ft. 32kHzLight Override & Secondary Relay

White ODCRA-000 Hard-Ceiling Raceway Adapter Kit – –

White ODCCG-000 Protective Cage for Ceiling-Mount – –Occupancy Sensors

Ultrasonic Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)Advanced Ultrasonic sensing technology for highly accurate monitoring with excellent immunity to air currents and other interference. All-digitalself-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect LevitonOccupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).

Commercial Grade Ultrasonic Ceiling-Mount Occupancy Sensors

COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY

White ODC05-U0W Ultrasonic Ceiling-Mount 180°, 500 sq. ft. 40kHzOccupancy Sensor

White ODC05-URW Ultrasonic Ceiling-Mount 180°, 500 sq. ft. 40kHzOccupancy Sensor with Ambient Light Override & Secondary Relay

White ODC10-U0W Ultrasonic Ceiling-Mount 180°, 1000 sq. ft. 32kHzOccupancy Sensor

White ODC10-URW Ultrasonic Ceiling-Mount 180°, 1000 sq. ft. 32kHzOccupancy Sensor with AmbientLight Override & Secondary Relay

White ODC20-U0W Ultrasonic Ceiling-Mount 360°, 2000 sq. ft. 32kHzOccupancy Sensor

White ODC20-URW Ultrasonic Ceiling-Mount 360°, 2000 sq. ft. 32kHzOccupancy Sensor with Ambient Light Override & Secondary Relay

White ODCRA-000 Hard-Ceiling Raceway Adapter Kit – –

White ODCCG-000 Protective Cage for Ceiling-Mount – –Occupancy Sensors

ODC10-U0W

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 22

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 22: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Com

mer

cial

Gra

de C

eilin

g-M

ount

& W

all-

Mou

nt O

ccup

ancy

Sen

sors

21

Occupancy SensorsCommercial Grade Ultrasonic, Multi-Tech & Infrared

Infrared Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect LevitonOccupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).

Commercial Grade Infrared Ceiling-Mount Occupancy Sensors

COLOR CATALOG NUMBER DESCRIPTION COVERAGE

White ODC04-I0W Infrared Ceiling-Mount 360°, 450 sq. ft.Occupancy SensorInfrared Ceiling-Mount

White ODC04-IRW Occupancy Sensor with Ambient 360°, 450 sq. ft.Light Override & Secondary Relay

White ODCRA-000 Hard-Ceiling Raceway Adapter Kit –

White ODCCG-000 Protective Cage for Ceiling-Mount –Occupancy Sensors

Multi-Technology Wall-Mount Occupancy Sensor (For use with Leviton Power Pack)Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect LevitonOccupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).

Commercial Grade Multi-Technology Wall-Mount Occupancy Sensor

COLOR CATALOG NUMBER DESCRIPTION COVERAGE OPERATING FREQUENCY

White ODW12-M0W Multi-Tech Wall-Mount 110°, 1200 sq. ft. 32kHzOccupancy Sensor

White ODW12-MRW Multi-Tech Wall-Mount 110°, 1200 sq. ft. 32kHzOccupancy Sensor with Ambient Light Override & Secondary Relay

Infrared Wide-View and High-Bay Wall Mount Occupancy Sensors (For use with Leviton Power Pack)Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect LevitonOccupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately).

Commercial Grade Infrared Wide-View Occupancy Sensors

Commercial Grade Infrared High-Bay Occupancy Sensors

COLOR CATALOG NUMBER DESCRIPTION COVERAGE

White ODWWV-I0W Infrared Wide-View Wall-Mount 110°, 2500 sq. ft.Occupancy SensorInfrared Wide-View Wall-Mount

White ODWWV-IRW Occupancy Sensor with Ambient 110°, 2500 sq. ft.Light Override & Secondary Relay

White ODWHB-I0W Infrared High-Bay Wall-Mount 120 ft, 14 ft. wide Occupancy Sensor @ 30 ft. heightInfrared High-Bay Wall-Mount

White ODWHB-IRW Occupancy Sensor with Ambient120 ft, 14 ft. wide

Light Override & Secondary Relay @ 30 ft. height

ODW12-M0W ODWWV-I0W ODC04-I0W

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 23

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 23: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

5300 Series

Six-Outlet Surge Strips5300 Series - 15A and 20A 120V AC Plug-In Devices

22

Power Q

uality Devices - Six-O

utlet Surge Strips

10 YEAR LIMITED

DESCRIPTION CATALOG NO. APPLICATION HOUSING COLOR

6-Outlet w/ Switch, w/ 6’ Cord 5300-PS Data-Sensitive Operations Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GS Data-Sensitive Operations Thermoplastic Gray6-Outlet w/ Switch, w/ 15’ Cord 5300-S15 Data-Sensitive Operations Thermoplastic Beige6-Outlet w/ Switch, w/ 15’ Cord 5300-G15 Data-Sensitive Operations Thermoplastic Gray6-Outlet w/ Switch, w/ 6’ Cord 5300-PST Telephone/Modem Line Protection Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GST Telephone/Modem Line Protection Thermoplastic Gray6-Outlet w/ Switch, w/ 6’ Cord 5300-PSC CATV Line Surge Protection Thermoplastic Beige6-Outlet w/ Switch, w/ 6’ Cord 5300-GSC CATV Line Surge Protection Thermoplastic GrayHospital Grade,Tamper-Resistant 5300-HTS Continues to supply power to load Aluminum Beige6-Outlet w/o Switch, w/ 6’ Cord if protection is lostHospital Grade,Tamper-Resistant 5300-H15 Continues to supply power to load Aluminum Beige6-Outlet w/o Switch, w/ 15’ Cord if protection is lost6-Outlet w/ Switch, w/ 6’ Cord 5300-IPS For use in rough environments Aluminum BeigeHospital Grade,Tamper-Resistant 5300-HT2 Continues to supply power to load Aluminum Beige6-Outlet w/o Switch, w/ 6’ Cord 20 AMP if protection is lost

ENVIRONMENTAL

STANDARDS & CERTIFICATIONS

5300 Series

5300-PSC5300-HT2

CATALOG NO. JOULES UL 1449 (2nd Ed) MAX.SURGE CURRENT NOISE REJECTION LOW VOLTAGE CLAMPINGIMPULSE 6kV/500A (test w/ 8x20us wave) (@100kHz-100MHZ) (UL 497A/B or UL 452)

5300-PS 1620 L-N: 330V L-N: 48KA -20 to -40 dB –

5300-GS 1620 L-N: 330V L-N: 48kA -20 to -40 dB –

5300-S15 1620 L-N: 330V L-N: 48kA -20 to -40 dB –

5300-G15 1620 L-N: 330V L-N: 48kA -20 to -40 dB –

5300-PST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V

5300-GST 1620 L-N: 330V L-N: 48kA -20 to -40 dB 270V

5300-PSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB –

5300-GSC 1620 L-N: 330V L-N: 48kA -20 to -40 dB –

5300-HTS 1080 L-N: 400V L-N: 36kA -20 to -40 dB –

5300-H15 1080 L-N: 400V L-N: 36kA -20 to -40 dB –

5300-IPS 1440 L-N: 330V L-N: 27kA -20 to -40 dB –

5300-HT2 1080 L-N: 400V L-N: 36kA -20 to -40 dB –

SPECIFICATIONS & FEATURES5300 SERIES

• Clamping profile tightly tracks AC sine wave.

• Six protected outlets with ON/OFF switch.

• Resettable circuit breaker andinternal fusing.

5300-HTS

• Tamper-proof, Hospital Grade receptacles

• Leakage current below UL 544 100VA limits

STORAGE TEMPERATURE-35�C to 60�C

OPERATING TEMPERATURE-10�C to 60�C

ANSI/IEEE Categories A & BC-62.41 & C-62.45

UL 1449, 1363, 1283#E146315

CSA#LR-94773

To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:� www.leviton.com

B-1027C HealthBrochure.qxd 7/11/06 2:03 PM Page 24

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com

Page 24: Hospital Grade Receptacles Power ... - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/74HCPROD.pdf · Hospital Grade Receptacles Power Status Tamper-Resistant SmartLock

Leviton Manufacturing Co., Inc. 59-25 Little Neck Parkway, Little Neck, NY 11362-2591Telephone: 1-800-323-8920 • FAX: 1-800-832-9538Tech Line (8:30AM-6:00PM E.S.T. Monday-Friday): 1-800-824-3005

Leviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9Telephone: 1-800-469-7890 • FAX: 1-800-563-1853

Leviton S.A. de C.V.General Arista 54-A Col. Argentina, Mexico D.F., C.P. 11270Telephone: 011-525-386-1131, 011-525-386-2052 • FAX: 011-525-386-1797

Visit us on the web at: www.leviton.com

© Copyright 2006 Leviton Manufacturing Co., Inc. All rights reserved. B-1027C/F6-tp

For our complete line of Industrial wiring device products, request Catalog IPD-2.05.

B-1027C HealthBrochure.qxd 7/11/06 2:02 PM Page 1

Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com