The iCup® is a zero-exposure urine drug screen that tests for up to 13 drugs in 1 device. This drug screen is fast and reliable, and the results can be photocopied for easy result recording.
The test device you select should be from an inno-vative and experienced leader. Perform initial rapid screening and order lab confirmation—all from one company. Now you’ll know.
iCup Instant Urine Drug Test
Call us Today at: 858.875.0265 www.confirmbiosciences.com [email protected]
![Page 2: "How It Works" - iCup Urine Drug Test Cup](https://reader035.vdocument.in/reader035/viewer/2022080123/5880e60d1a28ab0d358b59b3/html5/thumbnails/2.jpg)
©2013 Alere. All rights reserved. Reditest, iScreen, and the Redwood Toxicology Laboratory logo are trademarks of the Alere group of companies.
Features & benefits» Integrated test cup screens for
3-13 prescription and illicit drugs1
» FDA 510(k) Cleared; CLIA Waivedoptions available
» Integrated specimen validitycombinations available:CR, GL, NI, OX, PH, SG2
» Self contained cup minimizescollector exposure to urine
» Fast results in 5 minutes
11 000 0366 REV3
How it works. CERTIFICATION AVAILABLE ONLINE.PRODUCT TRAINING AND
Interpret test results at 5 minutes.
Collect specimen and secure the test lid.
Peel label to reveal drug test and specimen validity (if applicable)
Cap
Testing Chamber
Urine Cup
Peel Off Label
Temperature Strip
C
1
2
C
1
2
3
C
1
2
3
C
1
OX
pH
S.G.
NIT
CRE
GLUT
1.AMP2.COC3.THC
1.BZO2.BAR
1.MTD1.mAMP2.OPI3.PCP
C
1
2
C
1
2
3
C
1
2
3
C
1
1.AMP2.COC3.THC
1.BZO2.BAR
1.MTD1.mAMP2.OPI3.PCP
C
1
2
C
1
2
3
C
1
2
3
C
1
OX
pH
S.G.
NIT
CRE
GLUT
1.AMP2.COC3.THC
1.BZO2.BAR
1.MTD1.mAMP2.OPI3.PCP
Designated OperatorPeel Label to View Results
PRODUCT PROCEDURE NOTE: Refer to product insert for complete instructions, limitations, and warnings.
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) or liquid chromatography/tandem mass spectrometry (LC/MS/MS) are the preferred confirmatory methods. Clinical consideration and professional judgement should be applied to any drug of abuse test result, particularly when preliminary positive results are indicated.
1. Amphetamine (AMP), Barbiturates (BAR), Benzodiazepines (BZO), Buprenorphine (BUP), Cocaine Metabolites(COC), Marijuana (THC), MDMA (Ecstasy), Methadone (MTD), Methamphetamine (M-AMP), Opiates (OPI), Oxycodone (OXY), Phencyclidine (PCP), Propoxyphene (PPX) and Tricyclic Antidepressants (TCA).
2. Creatinine (CR), Glutaraldehyde (GL), Nitrate (NI), Oxidants (OX), ph (PH) and Specific Gravity (SG)
FOR PROFESSIONAL IN VITRO DIAGNOSTIC USE ONLY.
iScreen® iCup® / substance abuse screening device