how to set threshold setting and remote notification on the m2000

7
Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal 2012-11-02 HUAWEI Confidential Page1, Total7 How to set Threshold Setting and Remote Notification on the M2000(V2R11C01CP2302) Pre-requisites: 1.Access to EMS(M2000) 2.Username and Password for EMS 3.Performance Counter Parameters for Threshold Setting 4.Remote Notification function has been enabled and working on the M2000 Overview: In some special scenario,customers want to set up individual threshold settings on the M2000 and wants these thresholds to be set as an alarm.Once the threshold is reached,it will trigger corresponding alarms.These corresponding alarms are readily sent to them either by SMS or email through M2000 Remote Notification.This process will show an example on how to set it up on the M2000.Wimax NE version is V3R3C01SPC400 and M2000 version is V2R11C01CP2302.

Upload: c2poyraz

Post on 30-Oct-2014

74 views

Category:

Documents


2 download

DESCRIPTION

How to set Threshold Setting and Remote Notification on the M2000

TRANSCRIPT

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page1, Total7

How to set Threshold Setting and Remote

Notification on the M2000(V2R11C01CP2302)

Pre-requisites:

1.Access to EMS(M2000)

2.Username and Password for EMS

3.Performance Counter Parameters for Threshold Setting

4.Remote Notification function has been enabled and working on the M2000

Overview:

In some special scenario,customers want to set up individual threshold settings on the M2000 and

wants these thresholds to be set as an alarm.Once the threshold is reached,it will trigger

corresponding alarms.These corresponding alarms are readily sent to them either by SMS or email

through M2000 Remote Notification.This process will show an example on how to set it up on the

M2000.Wimax NE version is V3R3C01SPC400 and M2000 version is V2R11C01CP2302.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page2, Total7

1.On the M2000,click on Performance/Threshold Management/Threshold Setting.

2.On the Threshold Setting Tab,under Wimax BTS,click on Sector Carrier.Click on Add.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page3, Total7

3.On the Add threshold pop up window,select the objects(sites),enter the threshold name,and

select the Alarm Name.

4.If needed,you can add or modify the alarm name by clicking the “…” right next to it.Under

Alarm Name Setting,you can Add or Modify,as needed,then click OK.Note that this alarm name

will be the name of the alarm that will show on the M2000 alarm window once the threshold is

reached.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page4, Total7

5.On the Extended Threshold Information Tab,set the threshold type(single or

combined),Direction(increasing or decreasing),Function subset(from Performance Counter),the

counter name(for example : maximum number of online users),and the Alarm Severity that are

needed.On the example,we have set 150 as critical and 120 as Warning with Hysteresis of

10.Meaning,if the number is currently at 120 and increases by 10,it changes from Warning to

Minor.Click OK to save the threshold setting.

6.To set Remote Notification for the alarm that was set,on the M2000 click on Monitor,Alarm

Setting,and choose Remote Notification.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page5, Total7

7.On the Remote Notification Tab,click on Add and select Alarm Notification Rule.

For this example,let us take the current alarm 40925(Performance Threshold Default Alarm) as an

example for our remote notification setting.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page6, Total7

8.On the Add Remote Notification Rule pop up window,check(box) the Alarm Name and click the

“…” button.On the Select Alarm pop up window,click on Common Alarm and select the alarm

“Performance Threshold Default Alarm – 40925” and move it to the right side of the window

using the right arrow key.Then click OK.

9.Once the alarm name is already set,click Next.

Document Title:How to set Threshold Setting and Remote Notification on the M2000(V2R11C01SPC2302) Internal

2012-11-02 HUAWEI Confidential Page7, Total7

10.Select the Notification days and time,accordingly,then click Next.

11.Enter the email addreses of the recipients of the remote notification.Click Finish to complete

the notification.