how to up-grade rtn
DESCRIPTION
huaweiTRANSCRIPT
[HOW TO UPGRADE RTN LINK ]
Types of Up-gradation
a. Upgrade the Working Mode (Software).1) Case-1: To upgrade from 4E1 (1+0) to 16E1 (1+0)
2) Case-2: To upgrade from 4E1 (1+0) to 16E1 (1+1)
3) Case-3: To upgrade from 16E1 (1+1) to STM 1
b. Change the SCC Board (Hardware).c. Upgrade the Software version of IDU by TOOLKIT (without
changing SCC board).
Networks Product Line
Upgrade RTN-Release-12009-Feb-18
Procedure to Upgrade Microwave link
Tools & Test Equipment Required:
Wrapping Tool Punching Tool Tie Cutter
Screw Driver Set Bert Meter Label Printer
Measuring Tape Marker Pen Hammer
Hammer Multimeter Nose Pliers
Camera Wire Cutter Crimpling Pliers
Pliers Knife Ladder
2 Networks product line
Procedure to Upgrade Microwave link
Case 1
Objective:
To upgrade Huawei Microwave (RTN 600 series) from 4E1 (1+0) to 16E1 (1+0)
RTN Hardware Requirement:
PH1 Board Tributary cable DDF/Crone
RTN Software Requirement:
WEBLCT: With updated version (V2R6 software) Runtime Java (V5), required for WEBLCT
Tools & Test Equipment Required:
Punching/Wrapping tool Tie Cutter Screw driver setLabel Printer Knife E1 TagsTies BERT meter
Other Requirement
Revised Link Budget E1/DDF Plan Laptop with XP Windows LAN cable (With both sides RJ45 connectors)
3 Networks product line
Procedure to Upgrade Microwave link
Procedure: How to Upgrade;
1. Please refer to “How to Login in Huawei RTN” document, if you are having difficulty in login;
2. After you login, following window will appear;(Make sure, all cards are green color, which means “Installed & Running”
Saving “Cross Connect Configuration” (very important…)
3. Click NE (NE49136) click “Function tree” click “Configuration” & click “Cross Configuration”;
[Note down “Cross Connect Configuration (CCC)” or take snapshot for re-configuration][After “CCC” is saved, delete configuration]
Up-grade Working Mode
4. Starting from “Far end”, Up-grade working mode; (4E1, 7MHz, QPSK 16E1, 28MHz, QPSK)
4 Networks product line
Before up-gradation
After up-gradation
Procedure to Upgrade Microwave link
Creating “Cross Connect Configuration” (to restore services…)
5. Click NE Function tree Configuration Cross Connect Configuration;6. Click NEW Button.
7. Enter information of service (as saved) and click “OK” or “Apply”;
8. Install PH1 Board, DDF & Route the “Tributary cable”;
9. Patch E1 according to the given E1/DDF plan;
5 Networks product line
Procedure to Upgrade Microwave link
Case 2
Objective:
To upgrade Huawei Microwave (RTN 600 series) from 4E1 (1+0) to 16E1 (1+1)
RTN Hardware Requirement:
IDU 620 PH1 Board IF BoardTributary cables DDF/Crone IF cablesHybrid Coupler ODU
RTN Software Requirement:
WEBLCT: With updated version (V2R6 software) Runtime Java (V5), required for WEBLCT
Tools & Test Equipment Required:
Punching/Wrapping tool Tie Cutter Screw driver setBERT meter Ties E1 TagsLabel Printer Knife Hex key wrenchWrench Adjustable wrench Cable CutterAdhesive tape Weather proofing Crimpling PliersCamera Multimeter Heat Gun
Other Requirement
Revised Link Budget E1/DDF Plan Laptop with XP Windows LAN cable (With both sides RJ45 connectors)
6 Networks product line
Procedure to Upgrade Microwave link
Procedure: How to Upgrade;
1. Please refer to “How to Login in Huawei RTN” document, if you are having difficulty in login;
2. After you login, following window will appear;(Make sure, all cards are green color, which means “Installed & Running”
Saving “Cross Connect Configuration” (very important…)
3. Click NE (NE49136) click “Function tree” click “Configuration” & click “Cross Configuration”;
[Note down “Cross Connect Configuration (CCC)” or take snapshot for re-configuration][After “CCC” is saved, delete configuration]
Hardware Installation
4. Install Hybrid Coupler, ODU, IF Cable, IF Board, PH1 Board, Tributary Cable, and DDF.
7 Networks product line
Procedure to Upgrade Microwave link
Configuration
5. Make IF (1+1 Protection) and Configure the IDU according to the Revised Link Budget.
Up-grade Working Mode
6. Starting from “Far end”, Up-grade working mode; (4E1, 7MHz, QPSK 16E1, 28MHz, QPSK)
Creating “Cross Connect Configuration” (to restore services…)
7. Click NE Function tree Configuration Cross Connect Configuration;
8 Networks product line
Before up-gradation
After up-gradation
Procedure to Upgrade Microwave link
8. Click NEW Button. Enter information of service (as saved) and click “Apply” and “OK”;
9. Install PH1 Board, DDF & Route the “Tributary cable”;
10.Patch E1 according to the given E1/DDF plan;
After upgrade please run PRBS test.
Case 3
9 Networks product line
Procedure to Upgrade Microwave link
Objective:
To upgrade Huawei Microwave (RTN 600 series) from 16E1 (1+1) to STM1 (1+1)
RTN Hardware Requirement:
SL1 Board Patch Cord
RTN Software Requirement:
WEBLCT: With updated version (V2R6 software) Runtime Java (V5), required for WEBLCT
Tools & Test Equipment Required:
Camera Screw driver set TiesLabel Printer Adhesive tape
Other Requirement
Revised Link Budget E1/DDF Plan Laptop with XP Windows LAN cable (With both sides RJ45 connectors)
Procedure: How to Upgrade;
10 Networks product line
Procedure to Upgrade Microwave link
1. Please refer to “How to Login in Huawei RTN” document, if you are having difficulty in login;
2. After you login, following window will appear;(Make sure, all cards are green color, which means “Installed & Running”
Saving “Cross Connect Configuration” (very important…)
3. Click NE (NE49136) click “Function tree” click “Configuration” & click “Cross Configuration”;
[Note down “Cross Connect Configuration (CCC)” or take snapshot for re-configuration][After “CCC” is saved, delete configuration]
Up-grade Working Mode
4. Starting from “Far end”, Up-grade working mode; (16E1, 28MHz, QPSK STM-1, 28MHz, 128QAM)
Creating “Cross Connect Configuration” (to restore services…)
5. Click NE Function tree Configuration Cross Connect Configuration;
11 Networks product line
Before up-gradation
After up-gradation
Procedure to Upgrade Microwave link
6. Click NEW Button. Enter information of service (as saved) and click “Apply” and “OK”;
7. Click “Apply” and “OK”
After upgrade please run PRBS test.