How to connect S7-300 PLC to a computer?
This PLC tutorial will tell you how to connect you PLC to a computer. You will learn what kind of cables you can use. How to
download and upload Siemens drivers etc.
MORE TUTORIALS
You are here: Home PLC Articles How to connect S7-300 PLC to a computer? 1
Ads by Google Siemens S7 PLC PLC Programming Siemens PLC PLC Tutorial
Thursday, 30 April 2009 16:00
Fujitsu LIFEBOOK S751Try the new LIFEBOOK S751. With 2ndgeneration Intel® Core™ i7 vPro™.lifebook.me.ts.fujitsu.com
Free Programming CoursesGet started in minutes! Become a SoftwareEngineercode.he.net
PID Tuning SimulatorPID Practice & Testing on Simulator for DCSTechs & Control Engineerswww.picontrolsolutions.com
Software Engineer Degree100%Online Master Degree - SoftwareEngineering for Busy Programmers!EducationDegreeSource.com/Free_Info
PLC MEGAPACK
PLC MEGAPACK
Learn programmingPLC the easy w ay.
PLC Fundamentals -THE NUMBERSYSTEM
Boat Lift Controllerw ith Remote - PLCProgramming: Relaylogic
PLC Ladder LogicSimulator
Ladder LogicFundamentals andProgrammingExamples - PLCTutorial
How to connect S7-300 PLC to acomputer?
LOGIN
Forgot your password? Forgot your username? Create an account
Home PLC Video Tutorials PLC Articles PLC Ladder Simulator PLC Downloads PLC Classifieds PLC Questions
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 1/11
Step 7 Connecting, Downloading and Uploading
These are general guidelines for connecting, downloading and uploading from an S7-300 or S7-400 PLC. The following
procedures were created using Siemens SIMATIC STEP 7 version 5.4 software.
To start, open the SIMATIC Manager.
Connecting to the S7 PLC
The Programming Cables
There are three major types of programming cables:
1. The CP5512 card in a PCMCIA slot.
2. The PC Adapter using a serial or USB connection
GENERAL PLC
QUESTIONSPLC manual for siemens
LOGO!...
PC PLC Communication
PLC Softw are
Type of PLC as per...
project idea
send a ladder diagramme
of...
SIEMENS PLC
QUESTIONSlogo! 230rc
someone please please
please help...
Best internet tablet for
around...
SCADA: WinCC or
LabView ?
I w ant free ebook
“Automating...
has the pin up look...
Please tell me everything
about...
I am w orking w ith SIEMENS...
w here i can dow nload
siemens...
w hat is the latest version...
ALLEN BRADLEY PLC
QUESTIONSLooking for a new or...
Allen Bradley PLC
Programming softw are?
Rate and Comment: Caylee
Sophia...
sources of contamination for
allen...
how do i program an...
can anyboddy use the
allen...
PLC Allen bradley SLC 500...
does anybody know from
w here...
What is Allen-Bradley 1784-
PKTX/A?
How many digital i/os does...
How to diagnose PLCerrors?
Practical real lifeexamples on how toprogram PLC -advanced examplesfor PLC.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 2/11
3. An Ethernet cable
The CP5512 card and the PC Adapter can communicate on either an MPI or PROFIBUS port. Note that PROFIBUS is
labeled as DP on the Siemens connection ports. These cables can piggyback on existing connectors. Be aware that the
PC Adapter draws its power to work from the connection port so check the power LED for proper operation. The CP5512
card draws its power from the computer.
For Ethernet (TCP/IP) use a standard Ethernet cable from the computer to a CPU with an Ethernet port, a CP 343/443
module or a network switch all ready attached to the PLC network.
Checking Communications
With the programming cable plugged in, you can check for proper operation by clicking on the Accessible Nodes icon.
If communications are successful, you'll see a window pop up similar to the one below. If so, then close the Accessible
Nodes window and proceed to the download or upload section.
If communication fails then you will receive a message like below.
This indicates that the cable is not in the right computer port or the cable is not plugged in properly.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 3/11
Setting the PG/PC Interface
In order to start communication to the PLC you will need to match the "PG Interface" setting with the programming cable
and protocol. To do this, select the menu Options > Set PG/PC Interface.
The following dialog box will open up displaying all the different interfaces (i.e. communication drivers).
Each cable has its own interface. For Ethernet select the TCP/IP interface for your computers network card. Be careful not to
select your wireless Ethernet connection.
To get it working quickly it is best to select the interface with the Auto designation. This will discover working settings and
use them automatically.
For the PC Adapter click on the Properties button and make sure the Station Parameters Address is a unique network
address. It should not conflict with existing PLC and slave devices on the network. Also, check under the Local Connection
tab and make sure connection selection matches the port the cable is connected into.
Once the proper interface is selected and the properties are set then click OK and use the Accessible Nodes window to
check for successful communications. It should work. If not double-check the connection and cable. With the CP5512 and
PC Adapter cables, you should use the MPI port, as this is the default connection for Siemens.
If this doesn't work then I don't know what to tell you.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 4/11
Downloading
First, in order to enable the download menu commands, you must select the Block folder in the project's station you wish to
download.
There are three methods of downloading.
1. Partial download of selected blocks
2. Full download of all blocks and system data
3. Complete deletion of online PLC blocks and then downloading of all blocks and system data
Partial Download
Partial downloads are used in existing projects where only one or more blocks will be downloaded. To perform this type of
download select the block(s) you wish to download and then select the PLC > Download menu item or the download
button .
Holding down the Ctrl key or the Shift key allows more then one block to be selected at a time. Be careful though as the
order of download will occur in the order that the blocks were selected. This may mean that an error will occur if a block is
called before it is downloaded.
The CPU will need to be in Stop mode before downloading the System Data Block (SDB) as this is equivalent to a
hardware configuration download. This is usually not necessary in a PLC that has all ready had its hardware configured. If
you do download the system data, the following messages will prompt you through the transitions.
If the CPU is in Run mode then you will be prompted to Stop the CPU. The software will do the Run to Stop transition when
you click OK.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 5/11
After downloading the SDB you will be prompted to Run the CPU again.
Clicking Yes will automatically put the CPU back into run mode.
Full Download
To download all the blocks at once make sure you are in the Block folder and select the Edit > Select All menu item. Click
on the Download icon . You will be prompted to overwrite any existing blocks and if you want to load the system data
(see above).
Clearing the CPU Memory and then Downloading
The partial and full download methods above will overwrite existing blocks but will not any blocks from memory. In order to
completely delete the existing program in the CPU and download a new project select the Blocks folder and then use the
PLC > Download User Program to Memory Card menu item.
The following dialog box will pop up prompting you about the deletion of all the blocks and project data in the PLC. Click
Yes to perform the operation.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 6/11
After this, follow the normal download procedure.
Uploading
There are two methods for uploading. The first is when you have the original project and you want to preserve the symbols
and comments. The second method, when you don't have the original project, will upload everything from the CPU but will
have no associated documentation (i.e. symbols and comments).
Uploading to an Existing Project
With the existing project open, select the View > Online menu item.
This is the same as the Online button on the icon bar.
This will open up another window called the Online Partner. It shows the existing blocks inside the CPU. The Online
version is indicated by the highlighted title bar.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 7/11
There is a connection between these two versions so that uploading from the online partner makes sure to preserve all the
symbols and comments. Be careful. After uploading, make sure to close the online partner and do all work from the offline
version.
To upload individual blocks, select them in the Online view and choose the PLC > Upload to PG menu item. For a full
upload, select the Block folder and do the same.
Upload without an Existing Project
Follow these steps when you do not have the original project but wish to upload the program for backup purposes. With an
existing project open or a new blank project select the PLC > Upload Station to PG… menu selection.
In the next screen, fill in the slot the CPU is in (this is always 2 for S7-300) and the node address of the communication port
on the CPU. In the case below we are talking to a CPU over MPI with node address 10.
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 8/11
Quote
Quote
After clicking OK, the whole contents of the PLC including all blocks and hardware configuration will be uploaded into a
new station in the project.
While this project contains no documentation, it can be used as a backup to download later if needed.
source:http://www.plcdev.com
Last Updated ( Sunday, 27 December 2009 18:59 )
Comments
#16 2012-01-20 11:29
KOVAL ! why do you only respond to people who threaten to unsubscribe.viagra what about me....Id like a shout outtoo ....I watched all your videos....TWICE.....i loved you when you weren't? famous.... *sigh*
#15 2012-01-09 06:45
Hi friends.....i want One help plz help me Imm.........I used siemens 840dsl drive....i want to see plc program already iinstalled simatic s7 300 software but Hmi Does not shoow the s7 Icon.....How to access s7 icon to HMIdoftware....Plz send me ur suggestion imm ......
#14 2011-07-10 18:00
i want to know hat how to check communication b/t plc and hmi
1 2
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 9/11
Quote
Quote
Quote
Quote
Quote
Quote
Quote
Quote
1000 symbols left
Send
JC omments
#13 2011-06-24 13:01
hi calvin i am sending this page
#12 2011-06-03 00:40
Which data can, get out from PLC to PC displayed, is the PLC able to send out the data capture such, biner, hexa,digital,..please let me know,...thanks
#11 2011-05-25 04:51
Please tell me i can download plc programme from siemens S-7 300 plc with protool enviroment
#10 2010-11-19 22:14
i mean how to get ladder programming manula or literature
#9 2010-11-19 22:12
from where can i get Ladder programming manual
#8 2010-09-28 09:57
dear sir,which are the os will support to s7300 simatic manager and windows 7 will support or not...which are the adapter can communicate with simatic manager. I awaiting for ur reply.
Thanks & Regardssenthil
#7 2010-09-09 14:36
I have buy a CP5512 from www.bestincn.comeasy than the adapter!
Refresh comments list
RSS feed for comments to this post.
Add comment
Name (required)
E-mail (required)
Notify me of follow-up comments
Refresh
1 2
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 10/11
PLC Books - sometimes you just need a good book.
Programmable LogicControllers, Thir...
Frank Petruzella
Privacy Information
Activities Manual toaccompany Progr...
Frank Petruzella
Privacy Information
Introduction toProgrammable Logic C...
Gary A. Dunning
Privacy Information
ProgrammableControllers, Third Edit...
E. A. Parr
Privacy Information
Fundamentals ofProgrammable Logic C...
Jon Stenerson
Privacy Information
Programmable LogicControllers
John W. Webb, Rona...
Privacy Information
Copyright © 2012 plc-course.com. All Rights Reserved. Designed by Kursy online.Privacy Policy
13/05/2012 How to connect S7-300 PLC to a comp…
plc-course.com/…/how-to-connect-co… 11/11