howdens professional fast fit light oak chevron flooring...flooring 20 years domestic warranty 5...
TRANSCRIPT
HowdensProfessional
Fast FitLight OakChevronFlooring
20Years
DomesticWarranty
5Years MediumCommercial
Warranty
1291mm x 327mm x 8mm6 Panels Per PackCoverage 2.53m2Pack Weight: 18.31kgs
*Planks should beglued in a commercial
fit application(D3 PVA Glue)
AC 4
Important information
Features and benefits
Simple and quick installation with no tapping or glue required*
Sealed packs must be stored for at least 48 hours where they are to be laid.
Packs are to be laid flat on the floor with at least 50cm between packs and walls.
Packs should be stored in a room with a minimum temperature of 18°C.
Do not open packs until you are ready to install the flooring.
The fitting method for this flooring is unique and laying instructions must be followed on the reverse of this sheet
48
18 C
hrs
Compression proof& impact resistant
Suitable for hot water &electrical underfloor heating
Flooring can betaken up again
Planks can be independently fitted
*see stage 11 of installation
27°c max
EN 14041:2004
Laminate flooring for internal non structural use
40 Portman Square, London W1H 6LT
Howden Joinery Group Plc
13
HJ-003-JCv5
Reaction to fire: CLass CfI - s1
Content of Pentachlorophenol: <0.1 mg/kg (ppm)
Emission of Formaldehyde: Class E1
Slipperiness: NPD
Thermal Resistance: ≤ 0.15 (m²K)/W
Thermal Conductivity: NPDAquabloc
IMPORTANT LAMINATE FLOORING FITTING NOTICE
• Subfloor must be flat, smooth, clean and permanently dry
• Use spacers to create the required expansion gap (minimum 10mm) around the edge of the room and all fixed objects including door frames, radiator pipes & cabinet legs
• Check the moisture content of subfloor and apply suitable moisture barrier if required
• Short joints should be a minimum of 200mm apart from the short-end joint on the previous row
• Do not install kitchen cabinets on top of the floor
• Three ‘A’ planks and three ‘B’ planks are supplied in the pack. Plank types must be alternated row by row
6 Planksx3 (A) x3 (B)
HD912041
General Instructions
Pre-installation
Installation
Care & Maintenance
Clean the subfloor
SMOOTH
GRADUALLY INCREASETEMPERATURE BY 5° PER DAYTO A MAX OF 27°SEEK ADVICE FROM UNDERFLOOR HEATINGMANUFACTURER
CLEAN
DRY
Water and electric*systems can be used*electric systems must beencased in a minimum of 9mmof levelling compound
UNDERFLOOR HEATING
CHECK SUBFLOOR MOISTURE CONTENT
CONCRETE
CEMENT SCREEDS
ANHYDRITE
CONCRETE CEMENT SCREEDS ANHYDRITE FLOORBOARDS CHIPBOARD PLYWOOD
MAX27 C
NOTE:ADDITIONAL EXPANSION
GAP REQUIRED FOR RUNSLONGER THAN 20M IN
THE FORM OF A THRESHOLDSTRIP
10mm EXPANSION GAP
1m
Max 2mm
0mins
uv
115kgMAX
1
18°c - 27°c
48hrs
LEVELLINGCOMPOUND
FLOATING
MAKE SUREEXISTING TIMBER
SUB FLOORSARE SECURE
PLYWOOD OVEREXISTING FLOORS
IN POOR CONDITION
TOOLS REQUIRED
CHOOSE DIRECTION OF INSTALLATION
UNDERLAY REQUIRED
MINERAL BASED
DPMOR
MAX 0.5cm%Cement <2CM% 8 - 12% Moisture content
Breathable moisture barrieri.e - Bitumen moisture barrierpaper can be used
DPMCalcium Carbide Test
Always install a DPM where there areconcerns over moisture in the subfloor
TIMBER BASED
2 LAY UNDERLAY & FIT FIRST ROW
10mm
10mmTake planks from di�erent packs when fitting
10M Max
10M Max
Example of two rows laying from two packs. Each packcontains x3 planks (A) & x3 planks (B)
3 LAY FIRST TWO ROWS TOGETHER(diagram shows laying order example)
MEASURE & CUT PLANKSAS REQUIRED
LAY OTHER ROWS ONE AT A TIMEMAINTAINING CHEVRON PATTERN
>200mmPack 1 example (white)
Use spacers aroundthe edge of the room
>200mm
>200mm>200mm
PLANK REMOVAL
No steam mops should be used
Well wrung out mop andcleaning cloth can also be used
Slide the planks apart to release
Castor cups Soft castorsFelt pads
Entrance mats
ø
Fit into long edge, then slidealong and push down
Cut around frame Cut under the door frame
Ensure all panels are fully engaged and straight
FITTING AROUND OR UNDERDOOR FRAMES
5
Ensure expansion gaps are maintained
Note: Glue the cut section when cutting around pipes
10mm expansiongap required aroundpipework
6 CUTTING AROUND PIPEWORK
Measure width of panel required and cut
Ensure applicable expansion gap is maintained
7 LAST ROW
>50mm
10mm>50mm
>200mm
RH <70%
A
1 4 6 8 10
112 3 5 7 9
A A A
B B BBB
4 USE DOOR THRESHOLDSwhere required
8-10mm
25°
25°