huawei ne40e router quick ordering guide(2012-10-30).pdf
TRANSCRIPT
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
1/41
Huawei NE40E Router Quick Ordering Guide
Product Overview
The NetEngine40E series universal service router (NE40E) is a family of high-endnetwork products that are usually deployed at the edges of Internet Protocol (IP)
backbone networks, IP Metropolitan Area Networks (MANs), and other large-scale IP
networks. The NE40E, ME60, NE20E-S and NE5000E together provide a complete,
layered IP network solution.
The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks,
simplifying the network structure. With its ability to provide an extensive range of services
with reliable service quality, the NE40E is enabling IP and MPLS bearer networks to
develop greater broadband capacity and to become more secure, intelligent, and
service-oriented. Based on distributed hardware forwarding and non-blocking switchingtechnologies, the NE40E features line-rate forwarding capability, a well designed Quality
of Service (QoS) mechanism, strong service processing capability, and excellent
expansibility. The NE40E is based on a 400G platform and provides 100G line cards to
satisfy increased demand for bandwidth. Compatible with all line cards currently in use,
the NE40E minimizes the need for additional investments.
Ordering
NE40E Router Configuration Flow: Basic Configuration -Services BoardsSpecialService BoardsSoftware, LicenseElectrical or Optical Modules Cabinet Cables
Accessories
1 Basic Configuration
1Chassiswith powerSelect a chassis based on the number of service boardsrequired.
BOM Number SBOM Type Description Main
Control
Switc
hing
Servic
e
Slots
Power
Slots
Maximum Power
Consumption
02351596
CR52-BKPE-4
U-DC
NetEngine40E-X3,C
R5Z1BKPE,Integrate
d DC Chassis
Components(NE40E
-X3)-4U 1+1
Backup
In the
chass
is, no
need
to
config
ure
3 2
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
2/41
02351930
CR5B0BKP08
70
NetEngine40E,CR5Z
1BKP08A,NE40E-X8
Integrated Chassis
Components(Includi
ng 4 DC Power)
1+1
Backup
1
8 4
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
3/41
A4(Including 1*2G
Memory and 1*1G
CF Card)
cards, two DDR2 memory cards,
and two USB disks. By default, it
contains one 1 GB CF card and
one 2 GB memory card. The other
CF card, memory card, and USBdisks need to be prepared and
quoted additionally.
03053549
CR5D0SRUA5
70
NetEngine40E,CR5
7SRU200A5,Switch
and Route
Processing Unit
A5(Including One
2G Memory and
One 1G CF Card)
NE40E-X8
1:1 Preferred. It is optional for
supporting 100 Gbit/s LPUs and
supported in V600R003 or later
versions. Each device is equipped
with one or two pcs. It can be
configured with two CF cards, two
DDR2 memory cards, and two
USB disks. By default, it contains
one 1 GB CF card and one 2 GB
memory card. The other CF cards,
memory card, and USB disks
need to be prepared and quoted
additionally.
03030KSYCR5DSFUI407
C
NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit C
NE40E-X8
2+1
Not preferred
03053548CR5DSFUIE0
7C
NetEngine40E-CR57SFU200C0-200Gb
ps Switch Fabric
Unit C
NE40E-X8
2+1 Preferred. It is used to replace the
SFU with the BOM number as
03030KSY.
03030JTW
CR5D0MPUB
460
NetEngine40E,CR5
6MPUB4,Main
Processing Unit
B4(Including 1*2G
Memory and 1*1G
CF Card)
NE40E-X1
6
1:1 Mandatory and preferred. Each
device is configured with one
MPUD or two MPUB4s. Each
MPUB4 can be configured with
two CF cards, two DDR2 memory
cards, and two USB disks. By
default, each MPUB4 is attached
with one 1 GB CF card and one 2
GB memory card. The other CF
card, memory card, and USB
disks need to be prepared and
quoted additionally.
03030KSXCR5DSFUI407
B
NetEngine40E-CR5
7SFU40C0-40Gbps
Switch Fabric Unit B
NE40E-X1
6
3+1
Not preferred
03053547 CR5DSFUIE07B
NetEngine40E-CR57SFU200B0-200Gb
NE40E-X16
3+1 Preferred. It is used to replace the03030KSX. It is optional for
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
4/41
ps Switch Fabric
Unit B
supporting 100 Gbit/s LPUs and
mandatory for supporting 200
Gbit/s LPUs. It is used together
with the SRU200A5 and
supported in V600R003C00 or alater version.
3CF Card, Memory card and USB DisksConfiguration notes of the CF card, memory card and USB disks
BOM Number SBOM Type Model Description Remarks
02315064 CF-512M CF Card 512 MB CF card Mandatory.
02316042 CF-1G CF Card 1 GB CF card Mandatory.
02315063 MEM-1G-184pin MemoryCard
MEM-1G-184pin It is mandatory and of DDR
SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.
02316431 MEM-2G-240pin Memory
Card
2GB 240pin
memory moduleIt is mandatory and of DDR2
SDRAM type. This type of
memory cards is applied to
the MPUs on the NE40E-X3
and NE40E-X16 and SRU on
the NE40E-X8.
06010171 NUSBDSK01 USB Disk Storage, USB
disk,4GB/USB2.0
Optional. It is applied to the
SRU40A4 on the NE40E-X8
and the MPUB4 of the
NE40E-X16.
NE40E-X3
The CR52MPUD (03030KKR) of the NE40E-X3 can be configured with two CF cards
and the maximum capacity of a single CF card can be 1 GB.
By default, the CR52MPUD is already attached with one 1 GB CF card. During
http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=ext.huawei.huaweipart.HuaweiPart%3A1521623676&u8=1http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=ext.huawei.huaweipart.HuaweiPart%3A1521623676&u8=1http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=ext.huawei.huaweipart.HuaweiPart%3A1521623676&u8=1 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
5/41
configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
The CR52MPUD2 contains CF cards. Customers do not need to purchase
additionally.
The CR52MPUD (03030KKR) of the NE40E-X3 has one memory slot and supports
single DDR2 memory cards of a maximum of 2 GB.
By default, the CR52MPUD is already attached with a 2 GB memory card. You do not
need to purchase the memory card independently during the contract configuration.
The CR52MPUD2 contains 2 GB DDR3 memory cards. Customers do not need to
purchase additionally.
CR52-MPUD does not support USB disks. CR5D0MPUD170 supports 2G USB and it
is contained and need not to be configured.
NE40E-X8
The CR57SRU40A4 (03030KSR) of the NE40E-X8 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR57SRU40A4 is already attached with one 1 GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number
being 02316042 is recommended.
he CR57SRU40A4 (03030KSR) of the NE40E-X8 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR57SRU40A4 is already attached with one 2 GB memory card.
It is recommended that the CR57SRU40A4 be configured with another memory card
of the BOM number 02316431 during the contract configuration.
The CR57SRU40A4 (03030KSR) of the NE40E-X8 supports two USB2.0 interfaces.
Each SRU40A4 supports a maximum of two USB disks, and each NE40E-X8 supports a
maximum of four USB disks. By default, no USB disk is configured. How many USB disks
(06010161 or 06010171) needs to be configured depend on customers' requirements.
The USB disk is used to upgrade the system software package. It is recommended that
each device be configured with one USB disk. After the upgrade, you need to copy the
system software package to the CF card.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
6/41
NE40E-X16
The CR56MPUB4 (03030JTW) of the NE40E-X16 can be configured with two CF
cards and the maximum capacity of a single CF card can be 1 GB.
By default, the CR56MPUB4 is already attached with one l GB CF card. During
configuration, you must configure another CF card. The CF card with the BOM number as
02316042 is recommended.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports 2 GB DDR2 SDRAM
memory cards and can be configured with a maximum of two such memory cards. The
CR56MPUB4 is already attached with one 2 GB memory card.
It is recommended that the CR56MPUB4 be configured with another memory card of
the BOM number 02316431 during the contract configuration.
In 1:1 mode of MPUs or SRUs, the capacity of the memory cards of the MPUs or
SRUs must be the same. The memory cards configured for one board must share the
same BOM number, and it is better to have them supplied by the same manufacturer.
The CR56MPUB4 (03030JTW) of the NE40E-X16 supports two USB2.0 interfaces.
Each MPUB4 supports a maximum of two USB disks, and each NE40E-X16 supports a
maximum of four USB disks. By default, no USB disk is configured. You can determine the
number of USB disks with the BOM number being 06010161 or 06010171 according to
customers' requirements. The USB disk is used to upgrade the system software package.
It is recommended that each device be configured with one USB disk. After the upgrade,
you need to copy the system software package to the CF card.
2 Service Slots
1Configuration Notes of the LPUF-10: The LPUF-10 (03038461) is a 10 Gbit/splatform for flexible cards. It provides four slots for flexible cards of the same type or
different types, and supports hot swap of flexible cards. The LPUF-10 supports a
maximum of 10-Gbit/s bandwidth. When the total bandwidth of ports in the four slots
exceeds 10 Gbit/s, the line-rate forwarding performance is not ensured.
BOM Number SBOM Type Description Remarks
03038461 CR53-LPUF-10 Flexible Card Line ProcessingUnit(LPUF-10,four slots) The LPUF-10 (03038461) is a 10 Gbit/splatform for flexible cards. It provides fourslots for flexible cards of the same type or
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
7/41
different types, and supports hot swap offlexible cards.
03030FSL CR53-P10-1xPOS/STM64-XFP
1-Port OC-192c/STM-64cPOS-XFP FlexibleCard(Occupy two slots)
Each flexible card occupies two subcardslots on the LPUF-10. It is stronglyrecommended that only P1XX beconfigured for each LPUF-10. The XFP
optical module needs to be preparedadditionally and each LPUF-10 can beconfigured with a maximum of one XFPoptical module.
03030EYA CR53-P10-8x100/1000Base-X-SFP
8-Port 100/1000Base-X-SFPFlexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of eightSFP optical modules. All interfaces supportthe sending of Ethernet synchronous clocksignals and meanwhile only the interface0/1 supports the receiving of Ethernet
synchronous clock signals.SFP optical modules with electricalinterfaces can be inserted into theinterfaces of each flexible card.
03030GBV CR53-P10-1xPOS/STM16-SFP
1-Port OC-48c/STM-16cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of oneSFP optical module.
03030GUG CR53-P10-2xATM/STM4-SFP
2-Port OC-12c/STM-4cATM-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of twoSFP optical modules.
03030GBR CR53-P10-4xATM/STM1-SFP
4-Port OC-3c/STM-1cATM-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of fourSFP optical modules.
03030HNJ CR53-P10-2xPOS/STM16-SFP
2-port OC-48c/STM-16cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10. The SFP optical
module needs to be prepared additionallyand each LPUF-10 can be configured witha maximum of two SFP optical modules.
03030JCX CR53-P10-4xPOS/STM16-SFP
4-port OC-48c/STM-16cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of fourSFP optical modules.
03030JCY CR53-P10-4xPOS/STM4-SFP
4-port OC-12c/STM-4cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to be
prepared additionally and each LPUF-10can be configured with a maximum of four
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
8/41
SFP optical modules.
03030JTY CR53-P10-4xPOS/STM1-SFP
4-port OC-3c/STM-1cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of fourSFP optical modules.
03030JUB CR53-P10-8xPOS/STM4-SFP
8-port OC-12c/STM-4cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of eightSFP optical modules.
03030JUA CR53-P10-8xPOS/STM1-SFP
8-port OC-3c/STM-1cPOS-SFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10
can be configured with a maximum of eightSFP optical modules.
03030KBB CR53-P10-2xcPOS/STM1-SFP
2-Port ChannelizedOC-3c/STM-1c POS-SFPFlexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of twoSFP optical modules.
03030HNE CR53-P10-4xE3/cT3-SMB
4-Port Clear ChannelE3/Channelized T3-SMBFlexible Card
Each flexible card occupies one subcardslot on the LPUF-10.
Coaxial cables are used as user cables.
03030KHP CR53-P10-24xcE1/cT1-DB100
24-Port ChannelizedE1/T1-DB100 Flexible Card(Supporting 1588v2)
Each flexible card occupies one subcardslot on the LPUF-10 and needs to beconnected to a conversion box through thecable (04070064). If the cable is a coaxialcable with SMB connectors, the conversionbox (02351608) is used. If the cable is atwisted-pair cable with RJ48 connectors,the conversion box (02351606 or02351607) is used.
03030KNE CR5M0E8GFA30 8-Port 100/1000Base-X-SFPFlexible CardA(P10-A,Supporting 1588v2)
Each flexible card occupies one subcardslot on the LPUF-10.
The SFP optical module needs to beprepared additionally and each LPUF-10can be configured with a maximum of eightSFP optical modules.
SFP optical modules with10M/100M/1000M electrical interfaces canbe inserted into the interfaces of eachflexible card.
In addition to IEEE 1588v2, all interfacessupport the sending and receiving ofEthernet synchronous clock signals.
02351606 DB100-24xRJ48-E1/T1-Box
24*E1/T1 DB100 to RJ48 PortConversion Box
Each flexible card (03030KHP) isconfigured with one conversion box.
02351607 DB100-48xRJ48-E1/T1-Box
48*E1/T1 DB100 to RJ48 PortConversion Box
Every two flexible cards (03030KHP) areconfigured with one conversion box.
02351608 DB100-24xSMB-E 24*E1 DB100 to SMB Port Each flexible card (03030KHP) is
http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1370796013&u8=1http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1370796013&u8=1 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
9/41
1-Box Conversion Box configured with one conversion box.
04070064 DB100-DB100-Cable-4m
Signal cable ,24E1 TransitCable,4m,D100M-I,3*CC16P0.4P430U(S)-I,D100M-I
Each flexible card (03030KHP) isconfigured with one cable.
2Configuration Notes of the LPUF-21: The LPUF-20 and LPUF-21 are newlyincreased in NE80E/40E V300R003. Adopting the SD588 processors, the LPUF-20 and
LPUF-21 are 20 Gbit/s platforms for flexible cards and support a maximum bandwidth of
20 Gbit/s. When the total bandwidth of the interfaces on the LPUF-20 and LPUF-21 in two
slots exceeds 20 Gbit/s, the line-rate forwarding performance is not ensured on all
interfaces. The LPUF-20/21 provides two slots for flexible cards of the same type or
different types. According to the support for hot swap of the flexible card, the LPUF-20 can
be classified into the LPUF-20 supporting hot swap (03030HVN and 02316416) and the
LPUF-20 that does not support hot swap (02315504 and 02315756). The LPUF-21supports hot swap of the flexible card.
In the case of the LPUF-20 that does not support hot swap of the flexible card, before
installing the LPUF-20, you need to first insert flexible cards into the LPUF-20, and before
removing flexible cards, you need to first remove the LPUF-20. In the case of the LPUF-20
that supports hot swap of the flexible card and the LPUF-21, you can install the
LPUF-20/21 and insert or remove the flexible cards in any order. The LPUF-20/-21-A
supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number SBOM Type Description Remarks
03030KJY CR52-LPUF-21-A Flexible Card LineProcessing Unit(LPUF-21,2sub-slots) A(L3VPN,MVPN,IPV6Enhanced)
Supports hot swap of the flexible card andis preferred.
Supports services such as L3VPN,MVPN, and enhanced IPV6.
Supports full-width and half-width flexiblecards.
03053989 CR5DLPUF202E Flexible Card LineProcessing Unit(LPUF-21,2sub-slots) E
Supports hot swap of subcards.
Supports services such as L3VPN,MVPN, and IPV6 enhanced.
Supports both half-width subcards andfull-width subcards.
Supports the traffic management function.Supports PPPoE users access.
The board is supported sinceV600R005C00.
03030GSG CR52-P20-12x10/100/1000Base-TX-RJ45
12-Port10/100/1000Base-RJ45Flexible Card
Each flexible card occupies one subcardslot on the LPUF-20/21.
03030GSK CR52-P20-1x10GBase WAN/LAN-XFP
1-Port 10GBaseWAN/LAN-XFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-20/21.
The XFP optical module needs to beprepared additionally and eachLPUF-20/21 can be configured with amaximum of one XFP optical module.
It supports the sending and receiving of
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
10/41
Ethernet synchronous clock signals.
03030GSH CR52-P20-12x100/1000Base-X-SFP
12-Port 100/1000Base-SFPFlexible Card
Each flexible card occupies one subcardslot on the LPUF-20/21.
The SFP optical module needs to beprepared additionally and eachLPUF-20/21 can be configured with amaximum of 12 optical modules. Allinterfaces support the sending of Ethernetsynchronous clock signals andmeanwhile only the interface 0/1 supportsthe receiving of Ethernet synchronousclock signals.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
03030HND CR52-P20-1xPOS/STM64-XFP
1-Port OC-192c/STM-64cPOS-XFP Flexible Card
Each flexible card occupies one subcardslot on the LPUF-20/21.
The XFP optical module needs to beprepared additionally and eachLPUF-20/21 can be configured with amaximum of one XFP optical module.
03030JUJ CR52-P21-40x10/100/1000Base-TX-RJ45
40-Port10/100/1000Base-RJ45Flexible Card(Occupy twosub-slots)
It can be inserted into only the LPUF-21and each flexible card occupies twosubcard slots on the LPUF-21.
03030JUL CR52-P21-40x100/1000Base-X-SFP
40-Port 100/1000Base-SFPFlexible Card(Occupy twosub-slots)
It can be inserted into only the LPUF-21and each flexible card occupies twosubcard slots on the LPUF-21.
The SFP optical module needs to beprepared additionally and eachLPUF-20/21 can be configured with amaximum of 40 SFP optical modules. Allinterfaces of the flexible card support thesending of Ethernet synchronous clocksignals but each time only one interfacesupports the receiving of Ethernetsynchronous clock signals. The interfacesupporting the receiving of Ethernetsynchronous clock signals is selectedthrough software among the 40 interfaceson the flexible card.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
03030JUK CR52-P21-4x10GBase WAN/LAN-XFP
4-port 10GBaseWAN/LAN-XFP FlexibleCard(Occupy two sub-slots)
It can be inserted into only the LPUF-21and each flexible card occupies twosubcard slots on the LPUF-21.
The XFP optical module needs to beprepared additionally and eachLPUF-20/21 can be configured with amaximum of four XFP optical modules. Allinterfaces of the flexible card support thesending of Ethernet synchronous clocksignals but each time only one interfacesupports the receiving of Ethernetsynchronous clock signals. The interfacesupporting the receiving of Ethernetsynchronous clock signals is selected
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
11/41
through software among the fourinterfaces on the flexible card.
03030FDY CR52-P20-48x10/100Base-TX-RJ45
2-Port 10GBaseLAN/WAN-XFP+20-Port100/1000Base-X-SFPFlexible Card(P20,Occupy
two sub-slots)
It can be inserted into only the LPUF-21and each flexible card occupies twosubcard slots on the LPUF-21.
The XFP and SFP optical modules needto be prepared additionally and eachLPUF-20/21 can be configured with amaximum of 2 XFP optical modules and20 SFP optical modules.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
03030KKP CR52-P20-12x100/1000Base-X-SFP-A
1-Port 10GBaseWAN/LAN-XFP Flexible CardA(Supporting 1588v2)
Each flexible card occupies one subcardslot on the LPUF-20/21. Interfaces on theflexible card support the sending andreceiving of Ethernet synchronous clocksand IEEE 1588v2. The XFP opticalmodule needs to be prepared additionallyand each LPUF-20/21 can be configuredwith a maximum of one XFP opticalmodule.
03030KKQ CR5ML2XEEG20 12-Port 100/1000Base-SFPFlexible Card A(Supporting1588v2)
Each flexible card occupies one subcardslot on the LPUF-20/21.
The SFP optical module needs to be
prepared additionally and eachLPUF-20/21 can be configured with amaximum of 12 SFP optical modules.SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
All interfaces support IEEE 1588v2.
03030HVJ CR5M0EBGFB20
12-Port100/1000Base-X-SFPFlexible Card B(P20-B)
Each flexible card occupies one subcardslot on the LPUF-21 and supports PPPoEand IPoE. The SFP optical module needsto be prepared additionally and eachLPUF-21 can be configured with amaximum of 12 SFP optical modules.SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
03030HVH CR5M0L1XXB20
1-Port 10GBaseLAN/WAN-XFP Flexible CardB(P20-B)
Each flexible card occupies one subcardslot on the LPUF-21 and supports PPPoEand IPoE. The XFP optical module needsto be prepared additionally and eachLPUF-21 can be configured with amaximum of one XFP optical module.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
12/41
03030LVG CR5M0L1XXE20
1-Port 10GBaseLAN/WAN-XFP Flexible CardE(P20-E)
Each flexible card occupies one subcardslot on the LPUF-21 and supportsdownstream TM. The XFP optical moduleneeds to be prepared additionally andeach LPUF-21 can be configured with amaximum of one XFP optical module.
03030LVF CR5M0EAGFE20
10-Port 1000Base-X-SFPFlexible Card E(P20-E)
Each flexible card occupies one subcardslot on the LPUF-21 and supportsdownstream TM.
The XFP optical module needs to beprepared additionally and each LPUF-21can be configured with a maximum of 10XFP optical modules. XFP opticalmodules with 1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
3Configuration Notes of the LPUF-40: The LPUF-40 is a 40 Gbit/s platform for flexiblecards and supports a maximum bandwidth of 40 Gbit/s. The LPUF-40 provides two slots
for flexible cards of the same type or different types, and supports hot swap of the flexible
card.
The LPUF-40-A supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number SBOM Type Description Remarks
03030KWD
CR5MLPUF402A
Flexible Card LineProcessing Unit(LPUF-40,2sub-slots) A
(L3VPN,MVPN,IPv6Enhanced)
Supports hot swap of the flexible card andis preferred.
Supports services such as L3VPN,
MVPN, and enhanced IPV6.
03053990
CR5DLPUF402E
Flexible Card LineProcessing Unit(LPUF-40,2sub-slots) E
Supports hot swap of subcards.
Supports services such as L3VPN,MVPN, and IPV6 enhanced.
Supports the traffic management function.
Supports PPPoE users access.
The board is supported sinceV600R005C00.
03036967 CR5M00EEGF20 20-Port100/1000Base-X-SFP
Flexible Card(P40)
Each flexible card occupies one subcardslot on the LPUF-40.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
The SFP optical module needs to beprepared additionally and each LPUF-40can be configured with a maximum of 20SFP optical modules.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card.
The 100M SFP optical module issupported and a maximum of 20 100MSFP optical modules can be inserted into
http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370705334http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370705334 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
13/41
each flexible card.
03037070 CR5M0EEGFA20 20-Port100/1000Base-X-SFPFlexible CardA(P40-A,Supporting 1588v2)
Each flexible card occupies one subcardslot on the LPUF-40.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
The SFP optical module needs to beprepared additionally and each LPUF-40can be configured with a maximum of 20SFP optical modules.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of eachflexible card. All interfaces on the flexiblecard support IEEE 1588v2.
The 100M SFP optical module issupported and a maximum of 20 100M
SFP optical modules can be inserted intoeach flexible card.
03036752 CR5M00L2XX20 2-Port 10GBaseLAN/WAN-XFP FlexibleCard(P40)
Each flexible card occupies one subcardslot on the LPUF-40.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
The XFP optical module needs to beprepared additionally and each LPUF-40can be configured with a maximum of two
XFP optical modules.03038466 CR5M0L2XXA20 2-Port 10GBase
LAN/WAN-XFP Flexible CardA(P40-A,Supporting 1588v2)
Each flexible card occupies one subcardslot on the LPUF-40.
All interfaces support the sending ofEthernet synchronous clocks andmeanwhile only one interface supportsthe receiving of Ethernet synchronousclocks through software.
The XFP optical module needs to beprepared additionally and each LPUF-40can be configured with a maximum of twoXFP optical modules.
All interfaces on the flexible card support
IEEE 1588v2.
03030MDK CR5M0L2XXB20 2-Port 10GBaseLAN/WAN-XFP Flexible CardB(P40-B,Supporting PPPoEand IPoE)
Each flexible card occupies one subcardslot on the LPUF-40 and supports PPPoEand IPoE.
The XFP optical module needs to beprepared additionally and each LPUF-40can be configured with a maximum of twoXFP optical modules.
The flexible card is supported inV600R002C02 and later versions.
03030MDS CR5M0EEGFB20 20-Port100/1000Base-X-SFP
Flexible CardB(P40-B,Supporting PPPoE
Each flexible card occupies one subcardslot on the LPUF-40 and supports PPPoE
and IPoE.
The SFP optical module needs to be
http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370699398http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370798105http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370802623http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370802623http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370798105http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370699398 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
14/41
and IPoE) prepared additionally and each LPUF-40can be configured with a maximum of 20SFP optical modules.
SFP optical modules with10M/100M/1000M electrical interfacescan be inserted into the interfaces of each
flexible card.The 100M SFP optical module issupported and a maximum of 20 100MSFP optical modules can be inserted intoeach flexible card.
The flexible card is supported inV600R002C02 and later versions.
03030MLA
CR5D00EEGE70
20-Port10/100/1000Base-RJ45Flexible Card(P40)
Each subcard requires an LPUF-40subcard slot.
The board is supported by NE40E sinceV600R005C00.
03030LXH
CR5D00L4XX70
4-Port 10GBase
LAN/WAN-XFP FlexibleCard(P40,Occupy onesub-slot)
Each subcard requires an LPUF-40
subcard slot.
At most four XFP optical modules can beconfigured additionally for each card.
The board is supported by NE40E sinceV600R005C00.
03030LYU
CR5D0EEGFE70
20-Port 1000Base-X-SFPFlexible Card E(P40-E)
Each subcard requires an LPUF-40subcard slot. Supports traffic controlmanagement.
The SFP optical module is requiredadditionally. At most 20 SFP opticalmodules can be configured for eachsubcard.
SFP modules with electrical interfacescan be configured. SFP modules with10M/100M/1000M electrical interfacescan be inserted into ports. The LPUF-40board with 5A configuration can beequipped with 10 electrical interface SFPmodules at most. The LPUF-40 boardwith 7A configuration supports full 20electrical interface SFP modules.
The 100M SFP optical module issupported and each subcard can beinstalled with 20 100M SFP opticalmodules.
The board is supported by NE40E sinceV600R005C00.
03030MGC
CR5D0L2XXE70
2-Port 10GBaseLAN/WAN-XFP Flexible CardE(P40-E)
Each subcard requires an LPUF-40subcard slot. Supports traffic controlmanagement.
At most two XFP optical modules can beprepared additionally for each card.
The board is supported by NE40E sinceV600R005C00.
4Configuration Notes of the LPUF-100: The LPUF-100 is a 100G flexible card platformand supports a maximum bandwidth of 100 Gbit/s.The LPUF-100 provides four subcard
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
15/41
slots and supports the mixed configuration of subcards of various types. In addition, the
LPUF-10 supports hot swap of subcards.
The LPUF-100 supports services such as L3VPN, MVPN, and IPV6 enhanced.
BOM Number SBOM Type Description Remarks
03053589
CR5DLPUFA070
NetEngine40E,CR57LPUF101A0,100Gbps Flexible CardLine ProcessingUnit(LPUF-100,4 sub-slots)
Provides four subcard slots and supportsthe hot swap of subcards. Preferred;
Supports services such as L3VPN,MVPN, and IPV6 enhanced.
03030MXM
CR5D0L5XXA70
5-Port 10GBaseLAN/WAN-XFP Flexible CardA(P100-A,Supporting1588v2,Occupy twosub-slots)
It occupies two LPUF-100 subcard slots.
The XFP optical module is requiredadditionally. At most five XFP opticalmodules can be installed on each board.
All interfaces support 1588v2.
The board is supported by NE40E sinceV600R003.
03030MXA CR5D00EMGF72 48-Port100/1000Base-X-CSFPFlexible Card(P100,Occupytwo sub-slots)
It occupies two LPUF-100 subcard slots.
The CSFP single-fiber bidirectionaloptical module(34060525)is requiredadditionally. At most 24 CSFP single-fiberbidirectional optical modules can beinstalled on each board.
The board is supported by NE40E sinceV600R003.
03030NCF CR5D00EFGF70 24-Port100/1000Base-X-SFPFlexible Card(P100,Occupytwo sub-slots)
It occupies two LPUF-100 subcard slots.
The SFP optical module is requiredadditionally. At most 24 SFP optical
modules can be installed on each board.SFP modules with 10M/100M/1000Melectrical interfaces can be installed onthe subcard.
Supported by V600R003 and laterversions. The board is supported byNE40E since V600R003.
03030MXC CR5D0L5XFB70 5-Port 10GBaseLAN/WAN-SFP+ FlexibleCard B(P100-B,Occupy twosub-slots)
It occupies two LPUF-100 subcard slots.
SFP+ optical module is requiredadditionally. At most five SFP+ opticalmodules can be installed on each board.
03030MXN CR5D00P1MZ70 1-Port OC-768c/STM-256c
POS-2KM-LC FlexibleCard(P100,2 sub-slots)
No need SFP modules.
03030MXQ CR5D00P2XX70 2-Port OC-192c/STM-64cPOS-XFP FlexibleCard(P100,Occupy onesub-slot)
It occupies one LPUF-100 subboard slot.
XFP optical modules need to beconfigured additionally and it can beequipped with a maximum of two XFPoptical modules.
The subboard needs to be configuredwith guide rails and blank fillers.
BOM No. of the 1/4-width blank filler:21136332
BOM number of the guide rail: 21122042
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
16/41
55.5.5 Configuration Notes of the LPUI: The integrated LPU is not a flexible LPU. Theintegrated LPU includes the 100G LPUI-100 and 40G LPUI-41.
BOM Number SBOM Type Description Remarks
03053481 CR5D0LAXXA70 NetEngine40E,CR57L5XFA0,5-Port 10GBaseLAN/WAN-SFP+ FlexibleCard B(P100-B,Occupy twosub-slots)
The line-rate forwarding capability is 100Gbit/s;
The XFP optical module is requiredadditionally. At most 10 XFP opticalmodules can be installed on each board.
03053480 CR5D00EDXF70 NetEngine40E,CR57EDXFB0,16-Port 10GBaseLAN-SFP+ Integrated LineProcessing Unit (LPUI-100)
Converge the 160G board to the 80Gboard;
The SFP+ optical module is requiredadditionally. At most 16 SFP+ opticalmodules can be installed on each board.
03053421 CR5D00L8XX70 NetEngine40E,CR57L8XXB0
,8-Port 10GBaseLAN/WAN-XFP IntegratedLine Processing Unit(LPUI-41)
The line-rate forwarding capability is 40
Gbit/s;
The XFP optical module is requiredadditionally. At most eight XFP opticalmodules can be installed on each board.
03053422 CR5D00L4XX71 NetEngine40E,CR57L4XXB0,4-Port 10GBaseLAN/WAN-XFP IntegratedLine Processing Unit(LPUI-41)
The line-rate forwarding capability is 40Gbit/s;
The XFP optical module is requiredadditionally. At most four XFP opticalmodules can be installed on each board.
03053423 CR5D00EMGF70 NetEngine40E,CR57EMGFB0,48-Port100/1000Base-X-SFPIntegrated Line ProcessingUnit (LPUI-41)
The line-rate forwarding capability is 50Gbit/s;
The SFP optical module is requiredadditionally. At most 48 SFP opticalmodules can be installed on each board.
SFP modules with 10M/100M/1000Melectrical interfaces can be installed onthe subcard.
The CR57EMGFB0 supports 100M SFPoptical modules and each board can beinstalled with 48 100M SFP opticalmodules.
03053420 CR5DL2XEFG70 NetEngine40E,CR57L2XEFGB0,2-Port 10GBaseLAN/WAN-XFP+24-Port
100/1000Base-X-SFPIntegrated Line ProcessingUnit (LPUI-41)
The line-rate forwarding capability is 50Gbit/s;
The XFP optical module is requiredadditionally. At most two XFP opticalmodules can be installed on each board.
The SFP optical module is requiredadditionally. At most 24 SFP opticalmodules can be installed on each board.
SFP modules with 10M/100M/1000Melectrical interfaces can be installed onthe subcard.
03053542 CR5D0L4XXA70 NetEngine40E,CR57L4XXC0,4-Port 10GBaseLAN/WAN-XFP IntegratedLine Processing Unit
(LPUI-41,Supporting1588v2)
The line-rate forwarding capability is 50Gbit/s;
The XFP optical module is requiredadditionally. At most four XFP optical
modules can be installed on each board.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
17/41
03053543 CR5D0EKGFA70 NetEngine40E,CR57EKGFC0,40-Port100/1000Base-X-SFPIntegrated Line ProcessingUnit (LPUI-41,Supporting1588v2)
The line-rate forwarding capability is 50Gbit/s;The SFP optical module is requiredadditionally. At most 40 SFP opticalmodules can be installed on each board.
SFP modules with 10M/100M/1000Melectrical interfaces can be installed on
the subcard.
03053544 CR5DL2XEEG7A NetEngine40E,CR57EKGFC0,40-Port100/1000Base-X-SFPIntegrated Line ProcessingUnit (LPUI-41,Supporting1588v2)
The line-rate forwarding capability is 50Gbit/s;
The XFP optical module is requiredadditionally. At most two XFP opticalmodules can be installed on each board.
The SFP optical module is requiredadditionally. At most 20 SFP opticalmodules can be configured for eachboard.
SFP modules with 10M/100M/1000Melectrical interfaces can be installed on
the subcard.
The LPUI-100 can only be used on the NE40E-X8/X16, and must be used with the 200G
MPU and 200G SFU. CR5D0SRUA570(03053549) and CR5DSFUIE07C (03053548) are
needed on NE40E-X8; CR5DSFUIE07B (03053547) is needed on the NE40E-X16.
3 Special Service Boards
NE40E provides multiple types of services boards.
BOM Number SBOM Type Description Remarks
03030LXJ CR53-SPU-C NetEngine80E,CR53SPUCC0,VersatileService Process Unit C
The SPU does not provideinterfaces to connect to externalinterfaces. You can configuredifferent licenses for differentservices.
03053128 CR5MVSUF1010 NetEngine80E, CR52VSUF10, FlexibleCard Versatile Service Unit10(VSUF-10)
The VSUF does not provideinterfaces to connect to externalinterfaces. You can configuredifferent licenses for differentservices. The flexible card issupported in V600R002C02 and
later versions.
0305G062 CR5DVSUI201A (VSUI-20-A) The board is supported sinceV600R005C00.
4 Software, License
DescriptionStarting from V300R003, the NE40E/80E adopts the License-based salestrategy. The general principle is as follows:
1. Base package
The base package is mandatory item to be purchased for the NE40E/80E of each version,especially at a new site.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
18/41
2. Feature license
Feature licenses are controlled and are sold according to the features required by
customers. Feature licenses of the NE40E/80E are classified into device licenses and
board licenses. For device licenses, each device needs to be configured with one device
license, for example, a 1588v2 Function License for the 1588v2 feature. For boardlicenses, each board needs to be configured with one license, for example, the
LPUF-40-B Upgrade to LPUF-40-A License.
3. Upgrade fee
If customers attempt to upgrade the earlier versions to use new features, they need to pay
the upgrade fee. For upgrades on Huawei's account, such as bug fixing or contract
obligation, the upgrade fee is charged as required.
Software sale strategies may be adjusted. For detailed information about licenses on sale,
refer to the latest Quoter-d system.
BOM Number SBOM Type Description Remarks
88030YTE CR5S40BS6500 NetEngine40E&80E basicsoftware,VRP5, V600R005
Must be purchased for anew site.
81400135 SWP-CR53LIC-V3R3Update SWP-CR53LIC-V3R3Update NetEngine80E/40EV300R003 upgrade
88030BUW CR5S40EF0000 CR5S40EF0000 Software enhancement feefor upgrading theNE40E/80E from Rn toR(n+1).
81400189 CR5S40CLCK00 NetEngine40E&80E 1588v2Function License
It is a device license.
82400144 CR5S40BTOA00 NetEngine40E&80ELPUF-40-B Upgrade toLPUF-40-A License (L3VPN,Ability of MVPN, IPv6Enhanced)
It is a board license.
82400189 SWP-CR52LIC-21BToA NetEngine80E/40ELPUF-21/20-B Upgrade toLPUF-21/20-A License(IPv6, L3VPN, MVPN)
It is a board license.
82400137 SWP-CR53LIC-NetStream-SPUC NetEngine80E/40ENetStream License forSPUC
Each SPUC requires one.
82400141 SWP-CR53LIC-MVPN-SPUC NetEngine80E/40E MVPNLicense for SPUC
Each SPUC requires one.
82400140 SWP-CR53LIC-Tunnel-SPUC NetEngine80E/40E Tunnel(GRE, Lawful interception, 4over 6, etc.) License forSPUC
Each SPUC requires one.
82400204 CR5S40VIDE00 Resource,NetEngine40E&80E,LCR5VIDE00,NetEngine40E&80E VideoEnhanced Function License
Each VSUF-10 requiresone.
82400205 CR5S40SNAT00 NE40E&80E NAT Licensefor SPUC
Each SPUC requires one.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
19/41
81400208 CR5S40MHAG00 NE40E&80E Cross-chassisHAG Function License
It is a device license.
82400207 CR5S40BRAS00 NE40E&80E PPPoE/IPoEFunction License forLPUF-21
Each LPUF-21 requires one.
82400208 CR5S40BRAS01 NE40E&80E PPPoE/IPoEFunction License forLPUF-40
Each LPUF-40 requires one.
81400210 CR5S40L2TP00 NetEngine40E&80E L2TPFunction License
It is a device license.
81400281 CR5S4000LI00 NetEngine40E&80E LawfulInterception FunctionLicense
It is a device license.
81400279 CR5S400DAA00 NetEngine40E&80E DAAFunction License
It is a device license.
81400285 CR5S400MDI00 NetEngine40E&80E VideoMonitoring Function License
It is a device license.
82400240 CR5S40NATS00 NetEngine40E&80E 2MNAT Session License
It is a device license.
82400220 CR5S400DPI00 NetEngine40E&80E DPIFunction License forVSUF-10
Each VSUF-10 requires one
82400247 CR5S40DUAF00 NetEngine40E&80E DPISignature DatabaseUpgrading Annual Fee
It is a device license.
5 Electrical or Optical Modules
NE40E provides multi electrical and optical Modules.
Bom Description Mode Remarks
34060287
OpticalTransceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km
Multimode
Recommended
34060276
OpticalTransceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km
Singlemode
Recommended
34060281
OpticalTransceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km
Singlemode
Recommended
34060282
OpticalTransceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km
Singlemode
Recommended
34060287
OpticalTransceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km
Multimode
Recommended
34060299
OpticalTransceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km
Singlemode
Recommended
34060300
OpticalTransceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km
Singlemode
Recommended
34060301
OpticalTransceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km
Singlemode
Recommended
http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212236003http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212236003http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295182http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295182http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295095http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295095http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295095http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295095http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295182http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212295182http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212236003http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A212236003http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857http://pdm:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?u8&action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A163978857 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
20/41
34060555
BiDi Transceiver,CSFP,1550(Tx) /1310(Rx)nm,125~155Mbps,-14dBm,-8dBm,-28.2dBm,LC,SM,10km
Singlemode
Recommended
34060302
OpticalTransceiver,eSFP,1310nm,STM4,-15~-8dBm,-31dBm,LC,SM,15km
Singlemode
Recommended
3406030
3
Optical
Transceiver,eSFP,1310nm,STM4,-3~2dBm,-30dBm,LC,SM,40km
Single
mode
Recommended
34060304
OpticalTransceiver,eSFP,1550nm,STM4,-3~2dBm,-30dBm,LC,SM,80km
Singlemode
Recommended
34060286
Optical Transceiver,eSFP,850nm,2.125Gb/s(Multirate) ,-9.5~-2.5dBm,-17dBm,LC,MM,0.5km
Multi-mode
Recommended
34060219
Opticaltransceiver,eSFP,1310nm,1.25Gb/s,-9.5~-3dBm,-20dBm,LC,SM,10km
Singlemode
Sales restricted
34060298
OpticalTransceiver,eSFP,1310nm,1.25Gb/s,-5~0dBm,-23dBm,LC,SM,40km
Singlemode
Recommended
34060069
OpticalTransceiver,SFP,1550nm,1.25Gb/s,1dBm,-4dBm,-21dBm,LC(-40~85),40km
Singlemode
Recommended
34060274
OpticalTransceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km
Singlemode
Sales restricted
34060295
OpticalTransceiver,eSFP,1550nm,1.25Gb/s,0~5dBm,-30dBm,LC,SM,100km
Singlemode
Recommended
34100080
Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFPModule, Auto Negotiate, Maximum Transmission Distance 100m
Recommended
34060473
Opticaltransceiver,eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,LC,Single
Mode,10km
Singlemode
Recommended
34060360
OpticalTransceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km
Singlemode
Recommended
34060351
Opticaltransceiver,eSFP,1471nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
34060350
Opticaltransceiver,eSFP,1491nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
34060315
Opticaltransceiver,eSFP,1511nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k
m
Singlemode
34060332
Opticaltransceiver,eSFP,1531nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
34060346
Opticaltransceiver,eSFP,1551nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
34060347
Opticaltransceiver,eSFP,1571nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
3406034
8
Optical
transceiver,eSFP,1591nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Single
mode
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
21/41
34060349
Opticaltransceiver,eSFP,1611nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70km
Singlemode
34100080
Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFPModule, Auto Negotiate, Maximum Transmission Distance 100m
RJ45 Recommended
34060470
OpticalTransceiver,ESFP,Tx1310/Rx1490,1.25Gb/s,-3dBm,-9dBm,-19.5dBm,LC,Single Mode,10km
Singlemode
It must be usedwith the opticalmodule with theBOM numberbeing34060475.
34060475
OpticalTransceiver,ESFP,Tx1490/Rx1310,1.25Gb/s,-3dBm,-9dBm,-19.5dBm,LC,Single Mode,10km
Singlemode
It must be usedwith the opticalmodule with theBOM numberbeing34060470.
34060525 Integrated Optical Transmitting and ReceivingModule,CSFP,Transmitting:1490nm,Receiving:1310nm,1.25Gb/s,-9.0dBm,-3.0dBm,-19.5dBm,LC,10km
Singlemode It must be usedwith the opticalmodule with theBOM number34060470.
34060288
OpticalTransceiver,eSFP,1310nm,STM16,-10~-3dBm,-21dBm,LC,SM,2km
Singlemode
Recommended
34060278
OpticalTransceiver,eSFP,1310nm,STM16,-5~0dBm,-21dBm,LC,SM,15km
Singlemode
Recommended
34060289
OpticalTransceiver,eSFP,1310nm,STM16,-2~3dBm,-29dBm,LC,SM,40km
Singlemode
Recommended
34060279 OpticalTransceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km Singlemode Sales restricted.
34060488
OpticalTransceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km
Singlemode
Recommended
34060362
OpticalTransceiver,XFP,850nm,10.3Gb/s,-7.3dBm,-1.3dBm,-7.5dBm,LC,MM,0.3km
Multimode
Applied to the10 GBase LANonly
34060313
OpticalTransceiver,XFP,1310nm,9.95~10.71Gb/s,-6dBm~-1dBm,-14.4dBm,LC,SM,10km
Singlemode
Applied to the10 G POS, 10GBase LAN,and 10 GBaseWAN
34060322
Optical Transceiver,XFP,1550nm,9.95Gb/s to11.1Gb/s,+2dBm,-1dBm,-15dBm,LC,Single-mode,40km
Singlemode
Applied to the10 G POS, 10GBase LAN,and 10 GBaseWAN
34060361
Optical transceiver,XFP,1550nm,9.95Gb/s to11.1Gb/s,0~4dBm,-24dBm,LC,Single-mode,80km
Singlemode
Applied to the10 G POS, 10GBase LAN,and 10 GBaseWAN
34060494
XFP|SFP+ Opticaltransceiver,SFP+,850nm,10Gb/s,-7.3~-1dBm,-11.1dBm,LC,
MM,0.3km
Multi-mode
Can only beused in the
10GBase LAN.
3406049 XFP|SFP+ Optical Single Can only be
http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1301772803http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1301772803http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR:ext.huawei.huaweipart.HuaweiPart:1370076479http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1301772803http://pdm.huawei.com:8000/Windchill/servlet/WindchillAuthGW/wt.enterprise.URLProcessor/URLTemplateAction?action=ObjProps&oid=VR%3Aext.huawei.huaweipart.HuaweiPart%3A1301772803 -
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
22/41
5 transceiver,SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-12.6dBm,LC,SM,10km
mode used in the10GBase LAN.
34060518
XFP|SFP+ Opticaltransceiver,SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,-14.1dBm,LC,SM,40km
Singlemode
Can be used inthe 10G POS,10GBase LAN,and 10GBase
WAN..
34060570
High Speed Transceiver,CFP-1295nm 1300nm 1304nm1309nm-103.125Gbps--4.3dBm-4.5dBm--8.6dBm-SC-SMF-10km
single-mode
Can only beused in10GBase-CFPinterfaces..
6 Combinet
1 Combinet An assembly cabinet is optional. According to customers'requirements, an NE40E/80E can be installed in an assembly cabinet or in the
cabinet provided by the customer, or directly used without being installed in a
cabinet.
BOM SBOM Type Description Remarks
02113041 CR52-22-D NE80E,CR5B2N68E,2.2m Router AssemblyCabinet with DoubleSwing Doors,N68E-22
Applicable for NE40E-X3,NE40E-X16, and NE40E-X8
7 External Cable Suites
1 Configuration Notes of Power CablesConfiguration notes of external cables and terminals of the NEPS3000-D
Length in SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 25 m
25030101 Wire,450/750V,227 IEC02(RV)25mm^2,Blue,110A
Each power module is equippedwith one cable of this type. Thecable length is determined by thesite survey result.
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each power module is equippedwith one cable of this type. Thecable length is determined by thesite survey result.
14170121 Naked Crimpingconnector,JG2,25mm^2,M8,150A,Silver Plated
Each cable is equipped with oneterminal of this type, which isused to connect to the powermodule.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,Tin
Each cable is equipped with oneterminal of this type, which is
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
23/41
Length in SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Plating,Naked Ring Terminal used to connect to the powerdistribution frame.
Longer than 25 mand equal to orshorter than 35 m
25030199 Wire,450/750V,227 IEC02(RV),35mm^2,Blue,135A
Each power module is equippedwith one cable of this type. Thecable length is determined by thesite survey result.
25030420 Wire,450/750V,227 IEC02(RV),35mm^2,Black,135A
Each power module is equippedwith one cable of this type. Thecable length is determined by thesite survey result.
14170128 Naked CrimpingConnector,JG2,35mm^2,M8,210A,Tin Plating,For OEM
Each cable is equipped with oneterminal of this type, which isused to connect to the powermodule.
14170063 Naked CrimpingTerminal,OT,35mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which isused to connect to the powerdistribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NEPS5000-D
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 25 m
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
14170020 Naked CrimpingTerminal,OT,16mm^2,M6,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower module.
14170024 Naked Crimping
Terminal,OT,16mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminal of
this type, which is used to connect to thepower distribution frame.
Longer than 25 mand shorter than 35m
25030101 Wire,450/750V,227 IEC02(RV),25mm^2,Blue,110A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
14170147 Naked CrimpingTerminal,OT,25mm^2,M6,TinPlating,Width Less Than12.4mm,For OEM
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower module.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,Tin
Each cable is equipped with one terminal ofthis type, which is used to connect to the
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
24/41
Plating,Naked Ring Terminal power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NEPS8000-D
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 25 m
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
14170020 Naked CrimpingTerminal,OT,16mm^2,M6,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower module.
14170024 Naked CrimpingTerminal,OT,16mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower distribution frame.
Longer than 25 mand shorter than 35m
25030101 Wire,450/750V,227 IEC02(RV),25mm^2,Blue,110A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each power module is equipped with threecables of this type. The cable length isdetermined by the site survey result.
14170147 Naked CrimpingTerminal,OT,25mm^2,M6,TinPlating,Width Less Than12.4mm,For OEM
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower module.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminal ofthis type, which is used to connect to thepower distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the AC powerNEPS3000-A
BOM Number Description Configuration Notes
25030422 PowerCable,300/500V,227IEC10(BVV),Black(Cores:Blue,Brown,Yellow/Green),36A,3*6mm^2
Each power module is equipped with onecable of this type. The cable length isdetermined by the site survey result.
14170013 Naked Crimping Terminal,OT,6mm^2,M8,TinPlating,Insulated RingTerminal,12~10AWG,yellow
Each cable is equipped with three terminalsof this type, which are used to connect tothe power distribution frame.
14170017 Naked Crimping Terminal,OT,6mm^2,M4,Tin
Plating,Insulated RingTerminal,12~10AWG,yellow
Each cable is equipped with three terminals
of this type, which are used to connect tothe power module.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
25/41
Configuration notes of external cables and terminals of the AC power
NEPS5000-A
BOM Number Description Configuration Notes
25030463 PowerCable,300/500V,227IEC10(BVV),10mm^2,BlackJacket(Cores:Blue,Brown,Black,Yellow/Green),46A,4 EquivalentCores
Each power module is equipped withone cable of this type, which is used toconnect the AC power distributionframe and power distribution box.
04043396 Chinese AC Power Cable220V16A,3m,3*2.5mm 2,Black,I-Type AnglePlug,227IEC53-2.5^2(3C),C19 Straight Connector
Each power module is equipped withthree cables of this type, which areused to connect the power distributionbox and the input terminal of the ACpower module.
02120415 NetEngine5000E,CR5E3TSR,AC Distribution Frame
for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2Poles 20A Air Switch
Each device is equipped with 1 pcs.
The price of this item needs to beseparately quoted.
14170146 Common Terminal,Single Cord EndTerminal,Conductor Cross Section10mm^2,50A,Insertion Depth 18mm,Ivory
Each cable (25030463) is equippedwith three terminals of this type, whichare used to connect the input terminalof the power distribution box.
14170016 Naked Crimping Terminal,OT,10mm^2,M6,TinPlating,Naked Ring Terminal
Each cable (25030463) is equippedwith three terminals of this type, whichare used to connect the AC powerdistribution frame.
14170098 Common Terminal,Single Cord EndTerminal,Conductor Cross Section
2.5mm^2,12.5A,Insertion Depth 8mm,Blue
Each cable (04043396) is equippedwith three terminals of this type, which
are used to connect the output terminalof the power distribution box.
Configuration notes of external cables and terminals of the NE40E-X3 DC chassis
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 15 m
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with twocables of this type. The cable length is
determined by the site survey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each DC chassis is equipped with twocables of this type. The cable length isdetermined by the site survey result.
14170116 Naked CrimpingConnector,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with oneterminal of this type, which is used toconnect to the PEM.
14170024 Naked CrimpingTerminal,OT,16mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which is used toconnect to the power distribution frame.
Longer than 15 m
and shorter than 35m
25030101 Wire,450/750V,227 IEC
02(RV),25mm^2,Blue,110A
Each DC chassis is equipped with two
cables of this type. The cable length isdetermined by the site survey result.
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
26/41
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each DC chassis is equipped with twocables of this type. The cable length isdetermined by the site survey result.
14170119 Naked CrimpingConnector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
Each cable is equipped with oneterminal of this type, which is used toconnect to the PEM.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which is used toconnect to the power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables of the NE40E-X3 AC chassis
BOM Number Description Configuration Notes
04000104 External Suite, Power Cords All Over The World, Class IEquipment With Connector C13,External Cable Set
Different cables are used indifferent countries. Each ACchassis is equipped with 2 pcs.
Rules for selecting the AC power cable for the NE40E-X3 are as follows:
1. AC power cables are selected according to local cable standards in the country
where the device is deployed.
2. The required length of the power cables is determined based on the length in the
site survey.
3. The following formulas are used to calculate the number of required power
cables:
Number of power cables of each type = 2 pcs x Number of devices
In the 100V/110V/120V AC power supply system, input of double live wires is
required. In this case, the input voltage ranges from 176 VAC to 275 VAC, and any two
phases can be input to the AC power module. In the external cable suite (04000104), theC13-end of the three-core power cable has three terminals marked L, N, and PE. L
stands for live wire 1; N stands for live wire 1; PE stands for the ground wire. The other
end of the three-core power cable must be cut off for cable making. The terminal is
specified in the site survey.
In the 100V/110V/120V AC power supply system, if input of double live wires cannot be
provided, the NE40E-X3 AC chassis is not recommended.
Configuration notes of external cables and terminals of the NE40E-X8 DC chassis
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
27/41
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 15 m
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
14170024 Naked CrimpingTerminal,OT,16mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which is usedto connect to the power distributionframe.
14170116 Naked CrimpingConnector,JG2,16mm^2,M6,95A,Tin
Plated,for OEM
Each cable is equipped with oneterminal of this type, which is used
to connect to the PEM.
Longer than 15 mand shorter than 25m
25030101 Wire,450/750V,227 IEC02(RV),25mm^2,Blue,110A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which is usedto connect to the power distribution
frame.
14170119 Naked CrimpingConnector,JG2,25mm^2,M6,150A,TinPlating,For OEM
Each cable is equipped with oneterminal of this type, which is usedto connect to the PEM.
Longer than 25 mand shorter than 35m
25030199 Wire,450/750V,227 IEC02(RV),35mm^2,Blue,110A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
25030420 Wire,450/750V,227 IEC02(RV),35mm^2,Black,110A
Each DC chassis is equipped withfour cables of this type. The cablelength is determined by the sitesurvey result.
14170159 Naked CrimpingConnector,JG2,34.3mm^2,M6(1/4"),134A,Tin Plated,2AWG,Hole CenterDistance 15.875mm(5/8"),ShortTube,for North American
Each cable is equipped with oneterminal of this type, which is usedto connect to the PEM.
14170063 Naked CrimpingTerminal,OT,35mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with oneterminal of this type, which is usedto connect to the power distributionframe.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NE40E-X8 in AC
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
28/41
power supply mode
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
The distance betweenthe NE40E-X8 chassisand the AC-DCconverter is equal to orshorter than 3 m.
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A Each DC chassis is equipped with fourcables of this type. The cable length isdetermined by the site survey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each DC chassis is equipped with fourcables of this type. The cable length isdetermined by the site survey result.
14170116 Naked CrimpingTerminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with twoterminals of this type, which are used toconnect the PEM and AC-DC converter.
04080076 Monitor and AlarmCable,3m,D9M,CC4P0.48B(S),D9M
Each NE40E-X8 that adopts the ACpower supply mode is equipped withone monitor and alarm cable, which is
used to connect the AC-DC converterand the NE40E-X8 DC chassis.
The distance betweenthe NE40E-X8 chassisand the AC-DCconverter is longer than3 m.
(1) It is recommended to deploy the AC-DC converter near the DC chassis.
(2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment of
the AC power cable in the DC power supply system. In this case, the DC chassis cannot
manage the AC-DC converter.
The distance betweenthe AC-DC converterand the AC powerdistribution frame isequal to or shorter than50 m.
25030461 PowerCable,300/500V,227IEC10(BVV),6mm^2,BlackJacket(Cores:Blue,Brown),43A,2Equivalent Cores
Each AC chassis is equipped withfour cables of this type.
14170023 Naked CrimpingTerminal,OT,6mm^2,M6,TinPlating,Insulated RingTerminal,12~10AWG,yellow
Each AC power cable is equippedwith two terminals of this type on thetwo cores, which are used to connectto the binding post of the AC-DCconverter.
14170013 Naked CrimpingTerminal,OT,6mm^2,M8,TinPlating,Insulated RingTerminal,12~10AWG,yellow
Each AC power cable is equippedwith two terminals of this type on thetwo cores, which are used to connectto the binding post of the AC powerdistribution frame.
The distance betweenthe AC-DC converterand the AC powerdistribution frame islonger than 50 m.
An AC power distribution frame or the first power cabinet of a row should be placed near thedevice.
Configuration notes of external cables and terminals of the NE40E-X16 DC
chassis
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
29/41
Length in the SiteSurvey
Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
Equal to or shorterthan 15 m
25030430 Wire,450/750V,227 IEC02(RV),16mm^2,Blue,85A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
14170024 Naked CrimpingTerminal,OT,16mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminalof this type, which is used to connect tothe power distribution frame.
14170116 Naked CrimpingTerminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with one terminalof this type, which is used to connect tothe PEM.
Longer than 15 mand shorter than 35m
25030101 Wire,450/750V,227 IEC02(RV),25mm^2,Blue,110A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
25030432 Wire,450/750V,227 IEC02(RV),25mm^2,Black,110A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminalof this type, which is used to connect tothe power distribution frame.
14170119 Naked CrimpingConnector,JG2,25mm^2,M6,150A,Tin Plating,For OEM
Each cable is equipped with one terminalof this type, which is used to connect tothe PEM.
Longer than 25 mand shorter than 35m
25030199 Wire,450/750V,227 IEC02(RV),35mm^2,Blue,135A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
25030420 Wire,450/750V,227 IEC02(RV),35mm^2,Black,135A
Each DC chassis is equipped with eightcables of this type. The cable length isdetermined by the site survey result.
14170159 Naked CrimpingConnector,JG2,34.3mm^2,M6(1/4"),134A,Tin Plated,2AWG,HoleCenter Distance15.875mm(5/8"),Short Tube,forNorth American
Each cable is equipped with one terminalof this type, which is used to connect tothe PEM.
14170063 Naked CrimpingTerminal,OT,35mm^2,M8,TinPlating,Naked Ring Terminal
Each cable is equipped with one terminalof this type, which is used to connect tothe power distribution frame.
Longer than 35 m A power distribution frame or the first power cabinet of a row should be placed near the device.
Configuration notes of external cables and terminals of the NE40E-X16 in AC
power supply mode
Length in the Site Survey Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
The distance between the 25030430 Wire,450/750V,227 IEC Each DC chassis is equipped with
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
30/41
Length in the Site Survey Configurations of External Cables and Terminals
BOM Number Description Configuration Notes
NE40E-X16 chassis andthe AC-DC converter isequal to or shorter than 3
m.
02(RV),16mm^2,Blue,85A eight cables of this type. The cablelength is determined by the sitesurvey result.
25030428 Wire,450/750V,227 IEC02(RV),16mm^2,Black,85A
Each DC chassis is equipped witheight cables of this type. The cablelength is determined by the sitesurvey result.
14170116 Naked CrimpingTerminal,JG2,16mm^2,M6,95A,Tin Plated,for OEM
Each cable is equipped with twoterminals of this type, which are usedto connect the PEM and AC-DCconverter.
04080076 Monitor and AlarmCable,3m,D9M,CC4P0.48B(S),D9M
Each NE40E-X16 that adopts the ACpower supply mode is equipped withtwo monitor and alarm cables, whichare used to connect the AC-DC
converter and the NE40E-X16 DCchassis.
The distance between theNE40E-X16 chassis andthe AC-DC converter islonger than 3 m.
(1) It is recommended to deploy the AC-DC converter near the DC chassis.
(2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment
of the AC power cable in the DC power supply system. In this case, the DC chassis
cannot manage the AC-DC converter.
The distance between theAC-DC converter and theAC power distributionframe is equal to orshorter than 50 m.
25030461 PowerCable,300/500V,227IEC10(BVV),6mm^2,BlackJacket(Cores:Blue,Brown),43A,2Equivalent Cores
Each AC chassis is configured withfour cables of this type.
14170023 Naked CrimpingTerminal,OT,6mm^2,M6,TinPlating,Insulated RingTerminal,12~10AWG,yellow
Each AC power cable is equippedwith two terminals of this type on thetwo cores, which are used to connectto the binding post of the AC-DCconverter.
14170013 Naked CrimpingTerminal,OT,6mm^2,M8,TinPlating,Insulated RingTerminal,12~10AWG,yellow
Each AC power cable is equippedwith two terminals of this type on thetwo cores, which are used to connectto the binding post of the AC powerdistribution frame.
The distance between the
AC-DC converter and theAC power distributionframe is longer than 50m.
An AC power distribution frame or the first power cabinet of a row should be placed near the
device.
2 Configuration Notes of Ground CablesConfiguration notes of the ground cable and terminals used on the NE40E-X3
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC02(RV)25mm^2,yellow green,110A
Each device is equipped with one such power cable. Thelength of the power cable is based on the site surveyresult. If the device is grounded through a cabinet, the
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
31/41
BOM Number Description Configuration Notes
length of the ground cable is a1 shown in ; if the device is grounded through a chassis, thelength of the ground cable is a3 shown in .
14170119 Naked CrimpingConnector,JG2,25mm^2,M6,150A,TinPlating,For OEM
One such terminal is used to connect to the groundterminal on the chassis.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
When a device is grounded through a chassis, one suchterminal is used to connect to the ground bar in theequipment room.
If a device is grounded through a cabinet, one suchterminal is used to connect to the ground point on thecabinet.
Configuration notes of the ground cable and terminals used on theNE40E-X8/NE40E-X16
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC02(RV)25mm^2,yellow green,110A
Each device is equipped with one such powercable. The length of the power cable is based onthe site survey result. If the device is groundedthrough a cabinet, the length of the ground cable is
a1 shown in ; if the device isgrounded through a chassis, the length of the
ground cable is a3 shown in .14170119 Naked CrimpingConnector,JG2,25mm^2,M6,150A,Tin
Plating,For OEM
One such terminal is used to connect to the groundterminal on the chassis.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
When a device is grounded through a chassis, onesuch terminal is used to connect to the ground barin the equipment room.
If a device is grounded through a cabinet, onesuch terminal is used to connect to the groundpoint on the cabinet.
Configuration Notes of Ground Cable of the EPS200-4850A
The external AC-DC converter EPS200-4850A of the NE40E-X8/NE40E-X16 needs to be
separately grounded. Therefore, the 25 mm^2 ground cable is needed. The below lists the
configuration notes of the ground cable and terminals used on the EPS200-4850A.
Configuration notes of the ground cable and terminals used on the
EPS200-4850A
BOM Number Description Configuration Notes
25030431 Wire,450/750V,60227 IEC02(RV)25mm^2,yellow green,110A
Each device is equipped with one such power cable.The length of the power cable is based on the sitesurvey result. If the device is grounded through acabinet, the length of the ground cable is a1 shown in
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
32/41
; if the device is groundedthrough a chassis, the length of the ground cable is
a3 shown in .14170119 Naked Crimping
Connector,JG2,25mm^2,M6,150A,TinPlating,For OEM
One such terminal is used to connect to the groundterminal on the chassis.
14170060 Naked CrimpingTerminal,OT,25mm^2,M8,TinPlating,Naked Ring Terminal
When a device is grounded through a chassis, onesuch terminal is used to connect to the ground bar inthe equipment room.
If a device is grounded through a cabinet, one suchterminal is used to connect to the ground point on thecabinet.
3 Configuration Notes of Clock CablesList of clock cables that can be used in NE40E&80E V600R005C00
No. BOM Number Description Length Cable Type Configuration Notes
1 04022629 TrunkCable,20.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,HONET,DL2526
20 m Cable with oneSMB connectorwhich is used toconnect to theMPU/SRU. Theconnector on theother end of thecable must beprovided by thecustomer.
These cables are notsupported on theCR52MPUD.
EachCR52MPUA0/CR52SRUA0/CR52MPUB0/CR52SRUA1 can have 0to 4 pcs.
EachCR52MPUB2/CR52SR
UA3/CR56MPUB4/CR57SRU40A4 can have0 to 2 pcs.
2 04060205 TrunkCable,30.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,Wireless Intelligent Network
30 m
3 04023971 Trunk
Cable,40.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3133
40 m
4 04023972 TrunkCable,50.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2/0.25,C&C08B,DL3134
50 m
5 04060171 Trunk Cable,155MSelf-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34(S),SMB75SF-IV,OptiX
5 m Cable with twoSMB connectors
6 04040497 Trunk
Cable,3m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
3 m Cable with RJ48
connectors
Each
CR52MPUD/CR52MPUB2/CR52SRUA3/CR56MPUB4/CR57SRU40A4 can have 0 to 2 pcs.
These cables are notsupported on theCR52MPUA0/CR52SRUA0/CR52MPUB0/CR52SRUA1.
7 04040261 TrunkCable,15m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II
15 m
8 04040496 TrunkCable,30m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-II,Expert 2.0
30 m
9 04040494 TrunkCable,60.00m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),
60 m
-
5/22/2018 Huawei NE40E Router Quick Ordering Guide(2012-10-30).pdf
33/41
No. BOM Number Description Length Cable Type Configuration Notes
MP8-II,Expert 2.0
10 04040493 TrunkCable,80m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P430U(S),MP8-
II,Expert 2.0
80 m
11 14080082 Network Interface Connector,8Bit8Pin,Crystal Plug,Matching25050014
2 pcs Cable with RJ45connectors
These cables areoptional when the clockinterfaces on theCR52MPUD/CR52MPUB2/CR52SRUA3/CR56MPUB4/CR57SRU40A4 support 1PPS+TODor DCLS.
12 25050014 Twisted-PairCable,100ohm,Category 5eUTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use withPlug:14080082
Based onthe sitesurveyresult
Balanced cable
4 Configuration Notes of E1/T1 Interface CablesConfigurations of the conversion box and cables for the CR5M1CFE1
BOM Number Description Configuration Notes
02351606 NetEngine80E,CR5Z1DCRF,24*E1/T1DB100 to RJ48 Port Conversion Box
The conversion box of this type corresponds to oneCR5M1CFE1 LPU. The LPU and the conversion box areconnected through the 04070064 cable. The conversionbox is separately packaged.
02351607 NetEngine80E,CR5Z1DCRM,48*E1/T1DB100 to RJ48 Port Conversion Box
The conversion box of this type corresponds to twoCR5M1CFE1 LPUs. The LPU and the conversion box areconnected through two sets of 04070064 cables. The
conversion box is separately packaged.
02351608 NetEngine80E,CR5Z1DCSF,24*E1DB100 to SMB Port Conversion Box
The conversion box of this type corresponds to oneCR5M1CFE1 LPU. The LPU and the conversion box areconnected through the 04070064 cable. The conversionbox is separately packaged.
04070064 Signal cable,24E1 TransitCable,4m,D100M-I,3*CC16P0.4P430U(S)-I,D100M-I
It is used to connect the E1 conversion box and E1 LPU.Each LPU is equipped with one cable of this type.
If coaxial cables with SMB connectors are used,