Sorbisense
Passive sampling technology for effective groundwater monitoring
Hubert de Jonge, Bert Baan
CityChlor: Workshop on-site research and monitoring for chlorinated solvents in urban areas.
Utrecht, the Netherlands. March 2011
Sorbisense 2011
ContentIntroduction to passive samplingApplication areasTechnology, how it worksUser valueCases, references.
Sorbisense 2011
IntroductionGroundwater sampling primarily occurs with traditional pumping techniques (”spot samples”)Passive samplers have emerged since the 1990´s and have found widespread use in the US.Still marginally used in Europe.Major argument for using passive samplers is continuous sampling rather than discrete ”snap shots”
Sorbisense 2011
Application areas
Sorbisense 2011
GroundwaterSurface waterWastewater
Groundwater applications
Sorbisense 2011
Groundwater3D plume characterizationMonitoring performance of remediation activitiesMonitoring natual attenuationCompliance monitoring”Stable end situation”
Sorbisense method: technology (1)
Pressure gradients creates advective flow through SorbiCellSolid phase polymer adsorbs compounds to be measuredTracer salt is leached in proportion to water volumeAnalysis in laboratory (GC-MS, LC-MS, etc.)Concentration C derived from: C = M * Ks /(mo-mt)
De Jonge and Rothenberg; Pat. WO03098167Sorbisense 2011
SorbiCell – how it works
SorbiCell types – different solute groups
VOC: 55 VOC (halogenated, aromatics, degradation products)Oil, PAH, pesticidesHeavy metalsNutrients, MNA parameters
Sorbisense 2011
Sorbisense method – technology (2)
Mounting in groundwater wellsSorbiCell is clipped onto the GWS unit (various sizes) and mounted at the depth of the well screenHydrostatic water pressure fills the GWS unit, water inflow occurs through SorbiCell cartridgeAir is pressed out through air-hoseSampling interval 1 day 3 - monthsSampling from 0,5 - 100 m depthPrecision capillaries for flow control
Sorbisense 2011
Sorbisense method–technology
Time-averaged concentration values: more reliable results with dynamic/pulsed concentrationsEasy and precise vertical delineation of the plume Saves time (no pre-pumping)No waste water pumped to the surfaceNo service, power, maintenanceBetter logistics; preservation of the sample
Better decisions: save total project costs!
Sorbisense 2011
Sorbisense method- user value
User value (2)- time averaged concentrations
SKB projectCase: Rotterdam HarbourConsultant: Royal HaskoningProblem: Vinyl chloride plume, 20 m under GWLSampling period: 3 months4 reference samples with regular groundwater sampling
Sorbisense 2011
Peilbuis MP16
0
0,5
1
1,5
2
2,5
28-04-2007 17-06-2007 06-08-2007 25-09-2007
Viny
l chl
orid
e (u
g/L)
Watermonsters
Sorbisense 0309
Sorbisense 0312
Peilbuis MP19
0
20
40
60
80
100
120
28-04-2007 17-06-2007 06-08-2007 25-09-2007
Viny
l chl
orid
e (u
g/L)
Watermonsters
Sorbisense 0308
Sorbisense 0313
Peilbuis MP20
0
20
40
60
80
100
120
140
28-04-2007 17-06-2007 06-08-2007 25-09-2007
Viny
l chl
orid
e (u
g/L)
Watermonsters
Sorbisense 0314
Sorbisense 0315
Peilbuis MP22
0
5
10
15
20
25
30
28-04-2007 17-06-2007 06-08-2007 25-09-2007
Vin
yl c
hlor
ide
(ug/
L)Watermonsters
Sorbisense 0310
Sorbisense 0311
Sorbisense 2011
User value (3)- time averaged concentrations
Customer: Copenhagen Regional authoritiesConsultant: Grontmij Carl BroVOCl contaminationSampling period: 2 weeks2 reference sampes with regular groundwater samplesShort filter screens (single level) for horizontal mappingLonger filter screens with multi-level sampling for vertical delineation of plume
Sorbisense 2011
User value (4)- Plume delination in 3D
Sorbisense 2011
User value (5)- Vertical delineation of plume with ML sampler
Make optimal use of longer well screens
Sorbisense 2011
Long wells are ”problematic” and mostly usefull for screening purpose onlyNevertheless: many have been placed throughout Europe.Level specific groundwater sampling: expensive with regular methodsSorbisense Multilevel System is easily applicable: 30 min placementsGives precise information on vertical concentration gradients.
User value (6)- vertical delineation
Sorbisense 2011
Sagsnavn Initialer:Lokalitet: Dato:Sagsnr: Side: 1 af
Boring. nr.: B6-11 MP, placering: MP, kote (husk x): DNN DVR90 Bundpejling 20 m u.t. Bundpejling: m u. MP
Pumpetype: Mp-1 Start, kl.: Slut, kl.:Pumpens placering:2 m over bund Filtersætning: m u.t. - m u.t. Filtersætning m.u.MP - m.u.MP
Tidspkt. Pejling Kondukt. pH Temp. Prøve-(kl.) (m.u.MP) (mS/cm) (-) (mg/L) (%) (ºC) udtagning
13.30 16,21 1406 7,39 4,27 10,5 ?13.45 17,58 1404 7,42 4,44 10,4 ?14.00 17,62 1405 7,43 4,54 10,6 ?14.30 17,62 1403 7,44 4,62 10,5 ?14.35 17,62 1407 7,43 4,69 10,5 ?14.40 17,62 1403 7,43 4,7 10,5 ?14.45 17,62 1403 7,43 4,81 10,5 ?
?????
Forpumpningsberegninger ved 5 x filtervolumen:Pejling, vandspejl: m.u.MP - Pejling, filterbund: m.u.MP ? vandsøjle (h): mDiam,filter (fx mm = m Filtervolumen, (π x (D/2)² x h): π x ( / 2 )² m = m³ = L. 5 x filtervol.= literFlow (Q): L/minPumpetid for 5 x filtervolume(5xfiltervolumen)/Q : L / L / min = min
Nødvendigt værktøj til borings-adgang: Boring: unbracoskrue ? lås ? (Nøgle nr./lås nr.: )Boringsafslutning:
VANDPRØVETAGNING
Pejlepunkt (MP):kant filte m o/u terræn
Prøvetagn. slange: PE
SorbicellEgevej 3, Skuldelev30.8030.01
14-dec-10JMP
Ilt Pumpeydelse Bemærkninger(fx prøve id)(L/min)
10 L/ 94 sek brungrumset10 L/ 94 sek klart10 L/ 94 sek klart10 L/ 94 sek klart10 L/ 94 sek klart10 L/ 94 sek klart10 L/ 94 sek klart
Pre-pumpning: 75 min. (60-90)
User value (7) - time saving
Sorbisense 2011
User value (8) - time saving
No pre-pumping; hence no problems with low-yield wellsTypical installation time for mounting of groundwater units: 10-15 minutesDeep well mounting under 15 minutes!Nr. of field visits can be reduced
Documentation & referencesAn extensive list of documentation/ references, here among:
DK: Copenhagen authorities and waterworks (VOCl, pesticides)Grontmij Carl BroDK: DHI/ETV validerings project (VOCs)NL: SKB projectLab accreditations (Alcontrol NL)
International developments
Sorbisense 2011
Sorbisense A/S
Contact us at:Hubert de Jonge, [email protected]
Bert Baan, [email protected]
Sorbisense 2011
It is legal to use us ☺Quick ordering via EijkelkampEnabling services with lab analysesNL office soon to be established
Sorbisense 2011
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Sorbiceller
December 2010
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Sorbiceller
December 2010
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Sorbiceller
December 2010
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
1120
310
456
130
106
63238
14,7-
-<0,4
10960
50
1120
310
456
130
106
63238
14,7-
-<0,4
10960
50
500200
100
0 50m0 50m
N
1000B6.7 B3
B4B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Alm. vandprøver
Januar 2011
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Alm. vandprøver
Januar 2011
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
B6.7 B3B4
B6.6
B6.12
B6.11
B33
B6.8
B6.3
B31
B32
B6.9B6.10
B6.13
B6.14
B6.15
Egevej 3, Skuldelev
Alm. vandprøver
Januar 2011
Udbredelse af 1,1,1-TCA
Miljøteknisk boring med nr. og konc. µg/l. To værdier angiver øvre og nedre filter
700
360
580
120
52
84230
150,48
-0,97
3940
6,9
700
360
580
120
52
84230
150,48
-0,97
3940
6,9
500200
100
0 50m0 50m
N
Almost identical results with SorbiCells (left) and regular water samples (right)
User value (5)- horizontal delineation of VOCl plume