humastar 100 and 200 - human in afghanistan · humastar 100/200 • low water consumption 2nd...
TRANSCRIPT
HumaStar 100
HumaStar 200
Key advantages
Competition
Product features
Rev. 08d 07.09.2015
Scope of supply
The slides provided in this section are concerned with availability, scope of supply and registration
of the products.
Scope of delivery
Page 5
• Wash Add
• Special Wash
Solution (NaOH)
• Cuvette Clean
(turbidimetry)
Included:
Instrument UPS
Accessory Kit
Not included:
Computer & Monitor
(necessary for operation)
Printer
Wash Solutions (necessary for operation)
Key advantages at a glance
Page 18
Reliable results and flexibility
Reagents and instruments from one supplier
Page 19
• Reliable results
• HUMAN methods pre-installed and validated
• Reagent cooling
Reliable results, less application work, less
supports, less cost
• Flexibility (Open analyzer)
• Substrates, enzymes, turbidimetry, electrolytes
Flexible to use other reagents
Reliable methods
Page 20
More testing than for any other open instrument
• Validation on 4 analyzers running for almost 1 year
• More than 140.000 tests
• Recovery (8 different controls)
• Precision (intra-assay and inter-assay 5 days, 3 levelsfor each)
• Limit of linearity
• Limit of detection
• Calibration stability
• Onboard stability
• Method comparison (internal and/or external AU400)
Pre-installed methods
Page 21
The laboratory has reliable results without doing
any application work by themselves.
Clinical Chemistry
Page 22
Last updated: 02.01.2015
ACID PHOSPHATASE HbA1c liquidirect
ALBUMIN liquicolor HDL CHOLESTEROL liquicolor
ALKALINE PHOSPHATASE liquicolor HOMOCYSTEINE liquiUV
ALKALINE PHOSPHATASE opt. liquicolor IRON liquicolor
alpha-AMYLASE liquicolor IRON TPTZ liquicolor
auto-BILIRUBIN-D liquicolor LDH SCE mod. liquiUV
auto-BILIRUBIN-T liquicolor LDL CHOLESTEROL liquicolor
auto-CREATININE liquicolor LIPASE liquicolor
CALCIUM liquicolor MAGNESIUM liquicolor
CHLORIDE liquicolor PANCREAS-AMYLASE liquicolor
CHOLESTEROL liquicolor PHOSPHORUS liquirapid
CK NAC liquiUV POTASSIUM liquiUV
CK-MB liquiUV SODIUM liquicolor
CREATININE (enzym) liquicolor TOTAL PROTEIN liquicolor
gamma-GT liquicolor TRIGLYCERIDES liquicolor
GLUCOSE liquicolor UREA liquiUV
GLUCOSE liquiUVmono URIC ACID liquicolor
GOT (ASAT) IFCC mod. liquiUV URIC ACID liquicolor plus
GPT (ALAT) IFCC mod. liquiUV
Immunoturbidimetry
Page 23
Last updated: 20.01.2015
anti-STEPTOLYSIN-O (ASO) CYSTATIN-C liquidirect
APOLIPOPROTEIN A1 (APO A1) IMMUNOGLOBULINS direct IgA
APOLIPOPROTEIN B (APO B) IMMUNOGLOBULINS direct IgG
COMPLEMENT C3 IMMUNOGLOBULINS direct IgM
COMPLEMENT C4 MICROALBUMIN
CRP-hs TRANSFERRIN
Intuitive user software
Page 26
Optimized for touch screen
Reliable results
and easy creation of new methods
Complete reaction curve for EVERY test
Page 27
Reliable results
Statistics for every sample - not only QC
Page 28
Page 29
0
20
40
60
80
50 100 150 200 250 300
Sam
ple
po
sit
ion
s
Throughput max. [t/h]
Long walk-away time
High number of sample positions assures long walk-away time
Efficient workflow
Ready for automation of modern laboratories
Page 30
• LIS with standard
Ethernet cable
• Full random-access,
free choice of
execution order
• Continuous loading
and STAT
• Primary tubes• Internal barcode
reader included
1 2
3 4
• Bi-directional LIS
• LIS standardized
according ASTM
Maximum flexibility
Wide choice of sample and reagent vials
Page 31
50 ml bottles
20 ml bottles
5 ml tubes 1 ml
cups
Reagents
5 ml tubes
Primary tubes
1 ml cups
3 ml tubes
Up to 16x100mm, 10 ml
7 ml tubes 3.5 ml
cups
Samples
Unique and recognizable design
Page 32
Page 33
0 t/h
100 t/h
200 t/h
Mindray BS-120 HumaStar 100 Biosystems A15 HumaStar 200
High typical throughput
HumaStar 100 has a constant throughput
for 1- and 2-shot methods
Double Shot Methods
Maximum - Single Shot
Typical Mix
Thro
ugh
pu
t
100 t/h 64 t/h
95 t/h 127 t/h
Page 34
Economic and efficient operation
Cuvette Wash Station
• Very low carry-over
• 8-step wash cycle
• 2nd cleaning solution
• Extra washing definable in method
• Automatic monitoring of cuvettes
Page 35
• 30.000 tests with 80 cuvettes
Low consumable cost
Price per test on instruments
without wash station can be
more than double the price on
HumaStar 100/200
• Low water consumption
2nd cleaning solution
Page 36
Available on HUMAN homepage:
SERVICE > FAQ Cost per test calculation
Reduce expenses
New clinical chemistry family (low to medium throughput)
HumaStar 100
(March 2013)
HumaStar 200
(Mai 2013)
HumaStar 300SR
(2017)
• Identical user software
• Identical hardware components
Page 37
Reduce expenses
• Identical user software
Reduced staff training
Reduced end-user training
Reduced support
• Identical hardware components
Reduced spare part stock
Reduced training for service engineers
Faster repair
Page 38
Modern and easy connection
USB
Ethernet cable
Windows 7 or XP *
(32- or 64-bit)
Page 39
No old RS-232 cable
* Windows 8 compatibility in evaluation
No result will be lost
Failure proof connection
Page 41
Easy maintenance
Monitoring of lifetime
Page 42
Pumps
Lamp Filters
Cuvettes
Easy maintenance
Access to lamp and pumps
Page 43
Pumps
Lamp
• High quality components
• High production depth
• Made in Europe
• Extensive testing
Reliable quality
Page 44
Competitive
advantages
0
20
40
60
80
50 100 150 200 250 300
Sam
ple
po
sit
ion
s
Throughput max. [t/h]
Page 46
BS-120
A15
Page 47
A25
Pentra C200
Cobas C111 BS-200 C200i
C200iplus
C100
C100plus
HumaStar 100 – Feature comparison 1
Human
HumaStar 100
Horiba
Pentra C200
Mindray
BS-120
Biosystems
A15
Roche
Cobas C111
Open/closed Open Closed Open Open Closed
Throughput max. 100 t/h const. 90 t/h const. 100 t/h 150 t/h 60 t/h
Reagent cooling Yes Yes Yes No Yes
Wash station Yes No No No No
Sample pos. 60 15 8 48 8
Reagent pos. 30 15x2 *1 28 20 14x2 *1
Barcode Internal Internal External ? Smp. & Rgt.
Primary tubes 16x100 mm Yes Yes 15x100 mm 16x100 mm
LIS ASTM Yes Yes Yes ASTM
Weight 51 kg 95 kg 75 kg 45 kg 35 kg
Water consumpt. < 1 l/h < 2.1 l/h 2.5 l/h 0.5 l/h < 2 l/day
ISE No Optional Optional No Optional
Cuvettes 80 washable 192 disposable 40 disposable 120 disposable 60 disposable
Page 48
*1 Nbr. of methods X Reag. per method
HumaStar 100 – Feature comparison 2
Human
HumaStar 100
Landwind
C100
Vital Scientific
Pro XS
Human
HumaStar 80
Open/closed Open Open Open Open
Throughput max. 100 t/h const. 150 t/h 75 t/h 80 t/h
Reagent cooling Yes Yes Optional No
Wash station Yes No No No
Sample pos. 60 40 25 54
Reagent pos. 30 40 30 20
Barcode Internal External External External
Primary tubes 16x100 mm Yes Yes No
LIS ASTM Yes LIS-2A Yes
Weight 51 kg 50 kg 67 kg 42 kg
Water consumpt. < 1 l/h 3.5 l/h (C100plus) 0.25 l/h
ISE None Optional No No
Cuvettes 80 washable 81 disposable 48 disposable 144 disp.
Comments
C100plus with Wash
station Batch, Flow-Cell
Page 49
HumaStar 100 – Feature comparison 3
Human
HumaStar 100
ISE Logotech
Miura One
Open/closed Open Open
Throughput max. 100 t/h const. 120 t/h
Reagent cooling Yes Yes
Wash station Yes Yes
Sample pos. 60 15
Reagent pos. 30 19
Barcode Internal Optional
Primary tubes 16x100 mm 13x85 mm
LIS ASTM Yes
Weight 51 kg 42 kg
Water consumpt. < 1 l/h < 2 l/h
ISE None Optional
Cuvettes 80 washable 80 washable
Comments
Page 50
HumaStar 200 – Feature comparison 1
HumaStar
200
Mindray
BS-200
Biosystems
A25
Landwind
C200i
Open/closed Open Open Open Open
Throughput max. 200 t/h 200 t/h 240 t/h 225 t/h
Reagent cooling Yes Yes Yes Yes
Wash station Yes (2 sol.) No No No
Sample pos. 60 40 72 60
Reagent pos. 30 40 30 60
Barcode Internal Internal ? Optional
Primary tubes 16x100 mm Yes 15x100 mm Yes
LIS ASTM Yes Yes HL7
Weight 51 kg 116 kg 73 kg 120 kg
Water consumpt. < 2 l/h 3.5 l/h (BS-200E) 1 l/h < 1,5 l/h
ISE No Optional No Optional
Cuvettes 80 washable 80 disposable 120 disposable 81 disposable
Comments
BS-200E with wash
station
C200iplus with wash
station
Page 51
HumaStar 200 – Feature comparison 2
HumaStar
200
Elitech
Flexor EL80
Elitech
Flexor EL150
Elitech
Flexor EL200
Open/closed Open Open Open Open
Throughput max. 200 t/h 75 t/h 133 t/h 180 t/h
Reagent cooling Yes Optional Yes Yes
Wash station Yes (2 sol.) No Yes Yes
Sample pos. 60 25 25 80
Reagent pos. 30 30 30 32
Barcode Internal Optional external Internal Internal
Primary tubes 16x100 mm 13x75 mm 13x75 mm 13x75 mm
LIS ASTM LIS-2A LIS-2A LIS-2A
Weight 51 kg 67 kg 75 kg 95 kg
Water consumpt. < 2 l/h 250 ml/h 950 ml/h 500 ml/h
ISE No Optional Optional Optional
Cuvettes 80 washable 48 disposable 48 washable 48 washable
Comments Integraded PC Integrated PC
Page 52
HumaStar 200 – Feature comparison 3
HumaStar
200
Roche
Cobas C311
DiaSys
Respons 910
DiaSys
Respons 920
Open/closed Open Closed Closed Closed
Throughput max. 200 t/h 300 t/h 150 t/h 200 t/h
Reagent cooling Yes Yes No Yes
Wash station Yes (2 sol.) Yes No Yes
Sample pos. 60 110 30 30
Reagent pos. 30 42 (casseettes) 30 (x2) 30 (x2)
Barcode Internal Internal Internal Internal
Primary tubes 16x100 mm 16x100 mm 16x100 mm ?
LIS ASTM Yes (RS 232) Yes Yes
Weight 51 kg 270 kg 60 kg 110 kg
Water consumpt. < 2 l/h 12 l/h < 1 l/h < 7.5 l/h
ISE No Yes No Yes
Cuvettes 80 washable Washable 105 disposable 45 washable
Comments
Page 53
HumaStar 200 – Feature comparison 4
HumaStar 200 FUJIFILM NX 500 Miura 200 Pictus 200
Open/closed Open Closed Open Open
Throughput max. 200 t/h 128 t/h 240 t/h 200 t/h
Reagent cooling Yes Not necessary Yes No
Wash station Yes (2 sol.) Not necessary Yes (2 sol.) No
Sample pos. 60 1 49 48
Reagent pos. 30 ? 44 48
Barcode Internal Optional (extern) Optional (Smp&Rgt) Optional
Primary tubes 16x100 mm 16x100 mm 13x100 mm 13x100 mm
LIS ASTM Yes Yes ASTM
Weight 51 kg 25 kg ? 50 kg
Water consumpt. < 2 l/h None < 2 l/h <0.5 l/h
ISE No Yes Optional No
Cuvettes 80 washable Not necessary 80 washable 80 disposable
Comments POCT, dry chem. 1 arm
Page 54
HumaStar 200 – Feature comparison 4
HumaStar 200
Elitech
Selectra Pro M
Open/closed Open Open
Throughput max. 200 t/h 180 t/h
Reagent cooling Yes
Wash station Yes (2 sol.)
Sample pos. 60
Reagent pos. 30
Barcode Internal
Primary tubes 16x100 mm
LIS ASTM
Weight 51 kg
Water consumpt. < 2 l/h
ISE No
Cuvettes 80 washable
Comments
Page 55
vs.
Page 56
A15 HumaStar 100
HS100 vs. Biosystems A15
Page 57
Item Advantage Human Advantage Biosystems A15
Features • Wash Station (vs. disposable cuvettes)• Reagent refrigeration• UPS included• Sample barcode (especially interesting for LIS)• Crash detection of needle• Nbr. sample positions (60 vs. 48)• Nbr. reagent positions (30 vs. 20)• Show complete reaction curve
• 4 flexible racks for reagents and samples
Equivalent • No ISE• Primary tubes (16mm vs. 15mm)
• European origin• Open instrument
• 100 t/h constant vs. 150 t/h max (= ~95 t/h typical)
Methods/ Reagents
• Methods validated• One supplier for reagent and instrument
• Pre-filled in A15 reagent bottles (vs. MPR)
HS100 vs. Biosystems A15
Page 58
Explanation
Advantage HumaStar The main advantages of HumaStar 100 are the wash station and reagent refrigeration. The wash station saves money and time. Money: A15 has consumable cost for disposable cuvettes. HumaStar can run 30.000 tests with only 80 cuvettes. Time: On A15 manual changing of cuvettes is necessary after a test was run. Reagent refrigeration leads to reliable results, longer on-board and calibration stability. On A15 the user either has to place the reagent in the refrigerator after every run, but he will loose time doing this. If he leaves the reagent on the instrument he will waste reagent when it gets warm and he has to throw it away - he is loosing money. A15 has flexible tray for reagents and samples. However the total number of samples and reagents that the user can place on the instrument is higher on HumaStar. UPS and barcode scanner are included in the standard offer of HumaStar at no extra cost.
Equivalent Throughput: A15 has a maximum throughput which is 150 t/h, whereas HumaStar 100 can only reach a maximum of 100 t/h. But the throughput of HumaStar 100 is constant for 1- and 2-shot methods. In a typical mix A15 will only reach 95 t/h. => The throughput is equivalent on both instruments. Biosystems and Human both offer instruments, reagents, and validated methods “out of one hand”.
Advantage A15 Biosystems sells the reagent in bottles that can be placed directly on the instrument.
vs.
Page 59
Cobas C111 HumaStar 100/200
HS100/200 vs. Roche Cobas C111
Page 60
Item Advantage Human Advantage Roche Cobas C111
Features • Wash Station (vs. disposable cuvettes)• Big screen• A4 printing• Nbr. sample positions (60 vs. 8)• Up to 30 reagents/methods (vs. 14)
• Name and reputation of Roche• Small integrated PC, screen and printer• ISE (optional)
Equivalent • Reagent cooling• Primary tubes
• Sample barcode reader
Methods/ Reagents
• Pre-installed and validated methods
• Open instrument • Barcoded reagents in pre-filled bottles• 1-5 open channels (optional)
Throughput • 100 or 200 t/h (vs. 60 t/h)
HS100/200 vs. Roche Cobas C111
Page 61
Explanation
Advantage HumaStar The main difference is that Cobas C111 is a closed instrument. HumaStar 100/200 are open instruments. The user of HumaStar is not limited in the reagents and methods he wants to use on the instrument. Because Human has also pre-installed and validated methods, Cobas C111 does not have an advantage in that respect. There are three other massive advantages of HumaStar: -On HumaStar the user can place up to 60 samples, whereas only 8 samples can be placed on Cobas C111. This leads to a much a higher walk-away time on HumaStar. -The HumaStar has a wash station, which is much more cost and time efficient than disposable cuvettes on Cobas C111 (for explanation also see Biosystems A15). -HumaStar 100 and 200 are much faster than Cobas C111. The throughput of Cobas is only 60 t/h and much closer to HumaStar 80 than HumaStar 100 or 200.
Equivalent The possibility of automation of the laboratory workflow is equivalent on both instruments. HumaStar and Cobas C111 both can use primary tubes, they both have a built in sample barcode reader, both instruments have a standardized (ASTM) LIS protocol, and both instrument support continuous loading.
Advantage Cobas Roche reagents are ready to use in prefilled and barcode labeled bottles. Handling of reagent bottles is easier. The reputation of Roche is very good.
vs.
Page 62
Cobas C311 HumaStar 200
HS200 vs. Roche Cobas C311
Page 63
Item Advantage Human Advantage Roche Cobas C311
Features • Price of instrument and reagents • Low water consumption (<2 vs. 12 l/h) • Low energy consumption (<200 vs. 1500 VA) • Small footprint (width 69 vs. 134cm) • Low weight (51 vs. 270 kg) • LIS via RJ-45 (vs. RS-323) • No fixed water connection needed
• Name and reputation of Roche • ISE (optional) • Loading STAT and reagents without opening
instrument • Clot detection • More sample positions (110 vs. 60)
Equivalent • Reagent cooling • Primary tubes
• Sample barcode reader • Cuvette wash station
Methods/ Reagents
• Pre-installed and validated methods
• Open instrument (50 methods programmable: Human or open channels)
• Barcoded reagents in pre-filled bottles • Master-Curve calibration on reagents • 42 reagent cassette positions
(vs. 30 bottles on HumaStar)
Throughput • 300 t/h (vs. 200 t/h) photometric • 180 t/h ISE
HS200 vs. Roche Cobas C311
Page 64
Explanation
Advantage HumaStar The main difference is that Cobas C311 is a closed instrument. HumaStar 100/200 are open instruments. No limitations regarding reagents and methods he wants to use. There are three main advantages of HumaStar: -Price of the instrument itself is much lower than C311. -Price of multi-purpose reagents on HumaStar 100/200 is lower than reagents for C311. -No need of a fixed water connection (deionized water)*. -Lower consumption of water. -Lower consumption of energy and takes up less room in the laboratory.
Equivalent Both instruments offers pre-installed and validated methods, which assure reliable results.
Advantage Cobas Roche reagents are ready to use in prefilled and barcode labeled bottles. Handling of reagent bottles and loading of STAT is easier. Throughput of C311 is higher and it can load more reagents (parameters) at the same time. The reputation of Roche is very good. Cobas C311 can benefit most of its advantages an a high throughput laboratory.
* Roche also uses water to reconstitute the reagent (high quality necessary)
vs.
Page 65
Pentra C200 HumaStar 100
HS100 vs. Horiba Pentra C200
•Pentra C200 has192 cuvettes in stock
•*1 Reagent cassete with R1 and R2
Page 66
Item Advantage Human Advantage Pentra C200
Features • Wash Station (vs. disposable cuvettes*)• Nbr. reagent positions (30 vs. 15x2*1)• Nbr. sample positions (60 vs. 15)• Less weight (51 vs. 95 kg)
• ISE (optional)• Integrated computer and screen• Cooled sample tray
Equivalent • Fixed cycle (const. throughput) 100 vs. 90 t/h• Reagent cooling
• Intuitive touch screen user software• Sample barcode included• Shock detection of needle
• Primary tubes
Methods/ Reagents
• Pre-installed and validated methods
• Open instrument • Barcoded reagents in pre-filled bottles
HS100 vs. Horiba Pentra C200
Page 67
Explanation
Advantage HumaStar The main difference is that Pentra is a closed instrument. HumaStar 100/200 are open instruments. The user of HumaStar is not limited in the reagents and methods he wants to use on the instrument. Because Human has also pre-installed and validated methods, Pentra does not have an advantage in that respect. There are two other advantages of HumaStar: -On HumaStar the user can place up to 60 samples, whereas only 15 samples can be placed on Pentra . This leads to a much a higher walk-away time on HumaStar. -The HumaStar has a wash station, which is much more cost and time efficient than disposable cuvettes on Pentra (for explanation also see Biosystems A15).
Equivalent HumaStar 100 and Pentra both have a constant throughput which is approximately equivalent. Reagent cooling, primary tubes, sample barcode reader, and a shock detector are also present on both instruments.
Advantage Pentra Horiba offers reagents that are ready to use in prefilled and barcode labeled bottles. Handling of reagent bottles is easier. PC and monitor are integrated and do not need to be purchased separately.
HS100 vs. Horiba Pentra C200
Page 68
Customer claims… Possible reply!
“Pentra has an separate mixing unit. It should be faster.”
Pentra and HS100 both work with a fixed cycle. Thus having a fixed throughput for 1- and 2-shot reagents. HumaStar 100 has a 36 sec. cycle:
1 hour/36 sec. = 100 t/h Pentra C 200 has a 40 sec. cycle:
1 hour/40 sec. = 90 t/h => HS100 is even slightly faster than Pentra C200
“Because Pentra has disposable cuvettes, there is no carry over in the cuvettes. HumaStar 100/200 have washable cuvettes, which will lead to carry over.”
The washing procedure of HumaStar 100/200 is so sophisticated that carry over is comparable to disposable cuvettes. There are several measures to assure this: • 8- step washing of every single cuvette• Normal Systemic and a Special Wash solution are connected to the instrument (most
other instrument only have one type of wash solution).• A third wash solution „Cuvette Clean“ can be programmed in the methods settings if
necessary (e.g. turbidimetry).• The intensity of the washing can be increased from 1 (normal) to 4 (extended) in the
method settings if necessary.• The needle is washed internally and externally.• Incompatibilities can be defined in the method settings. This will prevent the
consecutive execution of parameters that could influence each other in one cuvette.=> In practice carry over is comparable on HumaStar and Pentra. HumaStar has the advantage of lower consumable cost (cuvettes).
vs.
Page 69
BS-120 HumaStar 100
HS100 vs. Mindray BS-120
Page 70
Item Advantage Human Advantage Mindray
Features • Wash Station• 60 sample positions (vs. 8)• Throughput 100 t/h const. (vs. 100 t/h max)• Internal sample barcode reader• Made in Europe• Intuitive touch screen user software
• Optional ISE
Equivalent • Reagent cooling• Nbr. reagent positions (30 vs. 28)
Methods/ Reagents
• Pre-installed and validated method• Reagents and instruments from one source
Service • Technical service available in most countries• Human offers local trainings
Comments
HS200 vs. Mindray BS-120
Page 71
Explanation
Advantage HumaStar
There are 5 massive advantages of HumaStar 100. -The wash station saves money and time. Money: BS-120 has consumable cost for disposable cuvettes. HumaStar can run 30.000 tests with only 80 cuvettes. Time: manual changing of cuvettes is necessary after a test has been run in a cuvette. -HumaStar 100 is much faster than BS-120. The max. throughput of BS-120 is 100 t/h, but the typical throughput will only be at approx. 60 t/h , because it is not constant for 1- and 2-shot methods. -On HumaStar the user can place up to 60 samples, whereas only 8 samples can be placed on BS-120. This leads to a much a higher walk-away time on HumaStar. -HumaStar is made in Europe. -HumaStar has pre-installed and validated methods. Users can be sure about the results. On BS-120 lots of time needs to be spend to reach a precision and performance of parameters as we have on HumaStar 100. Sometimes it will be impossible to reach the performance of HumaStar, because Human has the possibility to adapt the hardware and the software of the instrument to match the reagents. The user in the laboratory does not have this possibility. UPS and barcode scanner are included in the standard offer of HumaStar at no extra cost. The modern user software of HumaStar is easier to use and offers more features than Mindray.
HS200 vs. Mindray BS-120
Page 72
Explanation
Equivalent Reagent cooling. Number of reagent position is approximately equivalent.
Advantage BS-120
Optional ISE. However HumaStar can measure all electrolytes using chemical reagents. ISE modules often require high maintenance if the number of samples that are measured per day is not sufficient.
vs.
Page 73
Miura One HumaStar 100
HS100 vs. Miura One
Page 74
Item Advantage Human Advantage Miura One
Features • 60 sample positions (vs. 15)• 30 reagent positions (vs. 19)• Throughput 100 t/h constant
(vs. 150 t/h max., 76 typical)• Intuitive touch screen user software• UPS included• Primary tubes 16x100mm (vs. 13x85mm)
• Optional ISE• Optional internal reagent barcode reader
Equivalent • Wash Station• Reagent cooling• Made in Europe• Open instrument
• Needle crash detection• Internal sample barcode included
Methods/ Reagents
• Barcoded reagents
Service
Comments
vs.
Page 75
Kroma HumaStar 200
HS200 vs. Linear Kroma
Page 76
Item Advantage Human Advantage Miura One
Features • 60 sample positions (vs. 15)• 30 reagent positions (vs. 20)• Throughput 200 t/h (vs. 150)• Intuitive touch screen user software• UPS included• Primary tubes 16x100mm (vs. 13x100mm)
• Optional ISE• Internal reagent barcode reader
Equivalent • Wash Station• Reagent cooling• Made in Europe• Open instrument
• Needle crash detection• Internal sample barcode included
Methods/ Reagents
• Barcoded reagents
Service
Comments
vs.
Page 77
respons 910 HumaStar 200
HS200 vs. DiaSys respons 910
Page 78
Item Advantage Human Advantage respons 910
Features • Wash Station (vs. disposable cuvettes) • UPS included (end user value € 720) • Reagent refrigeration • Open instrument • Nbr. sample positions (60 vs. 30)
• Nbr. reagent positions (30 vs. 30x2) • STAT can be loaded without opening the cover
Equivalent • No ISE module • Barcoded primary tubes (16x100mm)
• European origin
Methods/ Reagents
• Methods validated • One supplier for reagent and instrument
• Pre-filled in respons reagent bottles (vs. MPR) • Internal reagent barcode reader
Throughput • Slightly higher (200 vs. 150 t/h)
HS200 vs. DiaSys respons 910
Page 79
Explanation
Advantage HumaStar The main advantages of HumaStar 200 is the wash station. The wash station saves money and time. Money: respons 910 has consumable cost for disposable cuvettes. HumaStar can run 30.000 tests with only 80 cuvettes. Depending on your price per disposable cuvette of respons 910, the price per test can be twice as high as on HumaStar 200. Time: manual changing of cuvettes is necessary after a test has been run in a cuvette. UPS is included in the standard offer of HumaStar at no extra cost. HumaStar 200 is an open instruments. The user of HumaStar is not limited in the reagents and methods he wants to use on the instrument. Because Human has also pre-installed and validated methods, respons does not have an advantage in that respect. Reagent refrigeration leads to reliable results, longer on-board and calibration stability. On respons the user either has to place the reagent in the refrigerator after every run, but he will loose time doing this. If he leaves the reagent on the instrument he will waste reagent when it gets warm and he has to throw it away - he is loosing money. Throughput of HumaStar 200 is 50 t/h higher than respons 910. This is difference can make a difference in laboratories with a higher number of samples per day. User can also place 60 samples on HumaStar at the same time. On respons 910 user can only place half of that (30 samples), making HumaStar 200 faster and more suitable if the laboratory has a higher number of samples per day.
HS200 vs. DiaSys respons 910
Page 80
Explanation
Equivalent DiaSys and Human both offer instruments, reagents, and validated methods “out of one hand”.
Advantage respons 910
DiaSys sells the reagent in bottles that can be placed directly on the instrument and are recognized by an internal barcode reader. On respons 910 user can place up to 30 different parameters, each of them can use up to two reagents. On HumaStar the user can place 30 different bottles. If a parameter uses two reagents it will occupy two positions, thus limiting the number of parameters loaded on the instrument. STAT samples can be loaded on respons 910 without opening the cover. On HumaStar 200 the user needs to press pause and wait for approx. 20 seconds before he can open the cover and place the STAT sample.
vs.
Page 81
respons 920 HumaStar 200
HS200 vs. DiaSys respons 920
Page 82
Item Advantage Human Advantage respons 920
Features • Water consumption (2 vs. 7.5 l/h) • UPS included (end user value € 720) • Open instrument • Nbr. sample positions (60 vs. 30) • Weight (51 vs. 110 kg)
• Nbr. reagent positions (30 vs. 30x2) • Optional ISE module • Constant throughput of 200 t/h •
Equivalent • Cuvette wash station • Reagent refrigeration
• European origin
Methods/ Reagents
• Methods validated • One supplier for reagent and instrument
• Pre-filled in respons reagent bottles (vs. MPR) • Internal reagent barcode reader
HS200 vs. DiaSys respons 920
Page 83
Explanation
Advantage HumaStar HumaStar 200 is an open instruments. The user of HumaStar is not limited in the reagents and methods he wants to use on the instrument. Users might be limited using respons 920, if they want to measure parameters that are not available from Diasys or reagents cannot be supplied on time. Because Human has also pre-installed and validated methods for its Multi Purpose Reagents, respons does not have an advantage in that respect. User can place 60 samples on HumaStar at the same time. On respons 920 user can only place half of that (30 samples), making HumaStar 200 more suitable if the laboratory has a high number of samples per day. HumaStar 200 is slightly smaller and its weight is only half the weight of respons 920. The water consumption of HumaStar 200 is much lower (< 2 l/h) than the water consumption of respons 920 (< 7.5 l/h)
HS200 vs. DiaSys respons 920
Page 84
Explanation
Equivalent HumaStar 200 and respons 920 are very similar instruments. Human and DiaSys both supply instrument and validated reagents out of one hand. Thus the user can be sure, to get reliable results. Both instruments have a cuvette wash station and reagent cooling. Both instruments are of European origin, thus having a good reputation in the market.
Advantage respons 920
DiaSys sells the reagent in bottles that can be placed directly on the instrument and are recognized by an internal barcode reader. On respons 910 user can place up to 30 different parameters, each of them can use up to two reagents. On HumaStar the user can place 30 different bottles. If a parameter uses two reagents it will occupy two positions, thus limiting the number of parameters loaded on the instrument. Respons 920 has an optional ISE module for Na, K, Cl, Li.
vs.
Page 85
A25 HumaStar 200
HS200 vs. Biosystems A25
Page 86
Item Advantage Human Advantage Biosystems A25
Features • Wash Station (vs. disposable cuvettes)• UPS included (end user value € 720)• Sample barcode included (value > € 500)
(especially interesting for LIS)• Shock detection of needle• Show complete reaction curve• Intuitive touch screen user software
• 3 independent sample racks
Equivalent • Nbr. sample positions (60 vs. 72), nbr. reagent positions (30 vs. 30)• No ISE
• Primary tubes (16mm vs. 15mm)• European origin
• Reagent refrigeration• Open instrument
Methods/ Reagents
• Methods validated• One supplier for reagent and instrument
• Pre-filled in A25 reagent bottles (vs. MPR)
Throughput • Slightly higher (200 vs. 240 t/h)
HS200 vs. Biosystems A25
Page 87
Explanation
Advantage HumaStar The main advantages of HumaStar 200 is the wash station. The wash station saves money and time. Money: A25 has consumable cost for disposable cuvettes. HumaStar can run 30.000 tests with only 80 cuvettes. Time: manual changing of cuvettes is necessary after a test has been run in a cuvette. UPS and barcode scanner are included in the standard offer of HumaStar at no extra cost. The modern user software of HumaStar is easier to use and more intuitive (see screen shots on next slide).
Equivalent Biosystems and Human both offer instruments, reagents, and validated methods “out of one hand”. Number of samples and reagents are approximately equivalent. On HumaStar you can place primary tubes up to 16 mm, on A25 you can place primary tubes up to 15 mm.
Advantage A25 Biosystems sells the reagent in bottles that can be placed directly on the instrument. Throughput of A25 is 20% higher than HumaStar 200. However, in routine use this difference will not be noticed by the user.
HS200 vs. Biosystems A25
Page 88
vs.
Page 89
BS-200 HumaStar 200
HS200 vs. Mindray BS-200
Page 90
Item Advantage Human Advantage Mindray
Features • Cuvette Wash Station• 60 sample positions (vs. 40)• UPS included• Made in Europe• Easy to use software• Less weight (51 vs. 116 kg)• Less water consumption (< 2 l/h vs. 3.5 l/h)
• Optional ISE• 40 reagent positions (vs. 30)
Equivalent • Throughput 200 t/h (even though Mindray has extra mixer)• Reagent cooling
Service • Technical service available in most countries• Human offers local trainings
Methods/ Reagents
• Methods validated• One supplier for reagent and instrument
Comments • BS-200E with Wash Station
HS200 vs. Mindray BS-200
Page 91
Explanation
Advantage HumaStar -If competing against BS-200 (not BS-200E): The wash station saves money and time. (see also A15 for explanation). If competing against BS-200E: The water consumption on HumaStar is lower. -On HumaStar the user can place up to 60 samples, whereas only 40 samples can be placed on BS-200. -HumaStar is made in Europe. -HumaStar has pre-installed and validated methods. (see also BS-120 for explanation) -UPS and barcode scanner are included in the standard offer of HumaStar at no extra cost. -The modern user software of HumaStar is easier to use and offers more features than Mindray. -The weight of HumaStar is only half the weight of BS-200.
Equivalent Throughput: The throughput on both instruments is approximately the same. Reagent cooling.
Advantage BS-200 Optional ISE. However HumaStar can measure all electrolytes using chemical reagents. ISE modules often require high maintenance if the number of samples that are measured per day is not sufficient. Number of reagent position is slightly higher. However multiple reagent trays can be handled (saved) by HumaStar.
vs.
Page 92
LW C200i HumaStar 200
HS200 vs. Landwind C200i
Page 93
Item Advantage Human Advantage Landwind C200i
Features • Cuvette wash station • Barcode scanner included • UPS included • Easy to use software • Made in Europe • Less weight (51 vs. 116 kg)
• Optional ISE • 60 reagent positions (vs. 30) • Slightly higher throughput (225 vs. 200 t/h)
Equivalent • Reagent cooling • 60 sample positions
Service • Human can offer technical service in most countries • Human offers local trainings
Methods/ Reagents
• Pre-installed and validated method • Reagents and instruments from one source
Comments • C200iplus with wash station (6 l/h)
HS200 vs. Landwind C200i
Page 94
Explanation
Advantage HumaStar -If competing against C200i (not C200iplus): The wash station saves money and time. (see also A15 for explanation). If competing against C200iplus: The water consumption on HumaStar is lower. -HumaStar is made in Europe. -HumaStar has pre-installed and validated methods. (see also BS-120 for explanation) -UPS and barcode scanner are included in the standard offer of HumaStar at no extra cost. -The modern user software of HumaStar is easier to use and offers more features than Landwind. Landwind software is very difficult to use. -The weight of HumaStar is only half the weight of C200i.
Equivalent Reagent cooling. Number of sample positions.
Advantage BS-200 The throughput is slightly higher on C200i. Optional ISE. However HumaStar can measure all electrolytes using chemical reagents. ISE modules often require high maintenance if the number of samples that are measured per day is not sufficient. Number of reagent position is higher. However multiple reagent trays can be handled (saved) by HumaStar.
vs.
Page 95
NX 500 HumaStar 200
HS200 vs. FUJIFILM NX 500
Page 96
Item Advantage Human Advantage NX 500
Features • Open instrument• A4 printout• 60 sample positions (vs. 1)• Lower price per test
• No calibration necessary• No water consumption• Compact and light weight• Optional plasma filter (whole blood)
Equivalent
Service
Methods/ Reagents
• More than 40 Human parameters pre-installed • Can be used with other reagents that areavailable on the market
• 28 + 3 parameters• FUJIFILM dri-chem reagent slides ONLY
Comments • Suited for central or hospital laboratories • Dry chemistry• POCT suited for physician's offices
HS200 vs. FUJIFILM NX 500
Page 97
Explanation
Advantage HumaStar -The HumaStar is an instrument suited for a central or hospital laboratory. It can load and run up to 60 samples at once. NX 500 can only run one sample at a time. NX 500 is a designated POCT instrument for physician’s offices or similar operation areas which run only very few samples. HumaStar also has an internal sample barcode reader, NX 500 only has an optional handheld scanner. -Price per test is much lower on HumaStar than on NX 500. NX 500 is optimized for easy operation, not for low cost or higher throughput. On NX 500 disposable consumables are used for plasma separation and pipetting (-> waste and cost). -HumaStar comes with more pre-installed parameters than NX 500. Some parameters, such as HbA1c are not available on NX 500. HumaStar is also an open system, you can use most clinical chemistry reagents that are available on the market. On NX500 you can only run the dry reagent slides which are provided by Fujifilm.
Equivalent
Advantage NX 500 -Easy operation: No on-site calibration necessary, no centrifugation of sample necessary. -Small footprint and low weight: Integrated computer and thermal printer.
vs.
Page 98
Pictus 200 HumaStar 200
HS200 vs. Pictus 200
Page 99
Item Advantage Human Advantage Pictus
Features • Wash Station (vs. disposable cuvettes)• UPS included (end user value € 720)• Reagent refrigeration• Primary tubes up to 16x100 mm (optional)• Sample barcode included (value > € 500)
(especially interesting for LIS)
• Nbr. reagent positions (30 vs. 48)
Equivalent • No ISE module• European origin
Methods/ Reagents
• Methods validated• One supplier for reagent and instrument
• Pre-filled reagent bottles (vs. MPR)
Throughput • Up to 200 t/h
HS200 vs. Diatron Pictus 200
Page 100
Explanation
Advantage HumaStar The main advantages of HumaStar 200 is the wash station. The wash station saves money and time. Money: Pictus 200 has consumable cost for disposable cuvettes. HumaStar can run 30.000 tests with only 80 cuvettes. Depending on your price per disposable cuvette of Pictus 200, the price per test can be twice as high as on HumaStar 200. Time: manual changing of cuvettes is necessary on Pictus 200 after a test has been run in a cuvette. UPS is included in the standard offer of HumaStar at no extra cost. Reagent refrigeration leads to reliable results, longer on-board and calibration stability. On Pictus 200 the user either has to place the reagent in the refrigerator after every run, but he will loose time doing this. If he leaves the reagent on the instrument he will waste reagent when it gets warm and he has to throw it away - he is loosing money.
Equivalent The throughput of both instruments is identical. Both instruments are of European origin. Both instruments offer validated applications for their reagents.
Advantage Pictus 200 -Users can load more reagents on board. (However these reagents must not stay on Pictus 200 for a long time, because it is not cooling the reagents.)
vs.
Page 101
Miura 200 (one arm) HumaStar 200
HS200 vs. Miura 200
Page 102
Item Advantage Human Advantage Miura 200
Features • Nbr. of sample positions (60 vs. 49)• More compact, less width on the desk (69 vs. 93cm)• Extractable reagent and samples trays• 4 types of reagent bottles (vs. 2)• 2 types of sample trays (4 types of tubes and cups)• Primary tubes up to 16x100 mm (optional)• Vitro-ceramic internally + externally coated probe (vs. no coating)• Internal + external needle wash• Continuous run, never stop, with rapid execution of urgent tests• Repetition of the calibration with recalculation of the results with the
new valid calibration• Multiple dyamic worklists (WL sheets)• LIS operating on dedicated WL sheets• Autodilution of the calibration including concentration of the sample
(dilution rate < 1)• Electronics easy accessible and separated from the hydraulics• Water consumption (mono-reagent 200 t/h) 1.5 l/h (vs. 3-4 l/h)• UPS included (end user value €720)• Sample barcode included (value>€500; especially interesting for LIS)
• Optional ISE module• Nbr. reagent positions (30
vs. 30/43)• Host query LIS• Optional internal reagent
barcode reader
HS200 vs. Miura 200
Page 103
Item Advantage Human Advantage Miura 200
Equivalent • Reagent cooling• Made in Europe• Open instrument
• Needle crash detection• Cuvette wash station
• Bi-directional LIS
Methods/ Reagents
• Methods validated• One supplier for reagent and instrument
• Pre-filled reagent bottles (vs. MPR)
Throughput • Up to 200 t/h (photometric)
HS200 vs. Logotech ISE Miura 200
Page 104
Explanation
Advantage HumaStar •UPS is included in the standard offer of HumaStar at no extra cost. •Sample barcode reader is included in the standard offer of HumaStar at no extra cost. •HumaStar 200 is more flexible in the type of reagent bottles you can use. You can use up to 4 different reagent containers (low dead volume = less reagent is wasted). •HumaStar 200 is more flexible in the type of sample tubes/cups you can use. On HumaStar 200 you have the choice between two different and extractable sample trays. You can also use 4 different sample tubes or cups and tubes up to 16mm diameter. •On HumaStar 200 you have internal AND external needle wash, minimizing shifted results due to needle carry-over. •HumaStar consumes less water than the Miura 200. •Imagine you have calibrated your instrument and you have finished running your patient tests. Then you find out that the calibration was not valid. On most instruments (including Miura 200) you would have to run all tests again. On HumaStar 200 you can just repeat the calibration and the recalculate all patient tests using the valid calibration. Thus your are saving a lot of reagent and time. •On HumaStar 200 electronic and hydraulic components are strictly separated. If there is a leakage in the hydraulics, the electronic components are protected from being destroyed by the water.
HS200 vs. Logotech ISE Miura 200
Page 105
Explanation
Equivalent •HumaStar 200 and Miura 200 are two very similar instruments. Some components areeven shared by both instruments. •Both instruments are of European origin.•Both instruments offer validated applications for their reagents.•Both instruments have a cuvette wash station and reagent refrigeration.•Photometric (without ISE) test throughput is 200 tests per hour on both instruments.
Advantage Miura 200 •Users can load more reagents on board. (However on HumaStar 200 it is possible towork with multiple extractable reagent trays.) •There is an optional ISE module for Na, K, Cl, Li available. (However Na, K, Cl areavailable for HS200 as liquid reagents.) •There are an optional internal reagent barcode reader and barcoded reagentsavailable. •Higher test throughput if ISE is included.
Product features
HumaStar 100 & 200
Product features
1. Design
2. Technology
• Main Features
• Hardware and Software
• Service and Maintenance
Page 109
Our Pioneers for a new Line of Instruments
HumaStar 100 & 200
Our Pioneers for a new Line of Instruments
Page 110
HumaStar 100 & 200
1. Design
2. Technology
• Main Features
• Hardware and Software
• Service and Maintenance
Page 111
Product features
0 t/h
100 t/h
200 t/h
HumaStar 80 HumaStar 100 HumaStar 180 HumaStar 200
HumaStar 100 & 200
Throughput
Maximum - Single Shot
Thro
ughput
Ma
xim
um
100 t/h
180 t/h
200 t/h
80 t/h
Page 112
0 t/h
100 t/h
200 t/h
HumaStar 80 HumaStar 100 HumaStar 180 HumaStar 200
HumaStar 100 & 200
Throughput Double Shot Reagents
Maximum - Single Shot
100 t/h
Thro
ugh
pu
t D
ou
ble
Sh
ot
100 t/h
Page 113
0 t/h
100 t/h
200 t/h
HumaStar 80 HumaStar 100 HumaStar 180 HumaStar 200
HumaStar 100 & 200
Throughput
* independent of single- or double shot methods
Double Shot Reagents
Maximum - Single Shot
Typical Mix
Thro
ugh
pu
t T
yp
ica
l
100 t/h
40 t/h
115 t/h 127 t/h
Page 114
HumaStar 100 & 200
Features • Open random-access
• Multi-step wash station
• Primary tubes (16x100 mm)
• Sample cups
• Reagent cooling
• 30 reagent and 60 sample positions
• Internal sample barcode reader
• Needle shock detector
• Bi-directional LIS (ASTM)
• Continuous loading
Page 115
HumaStar 100 & 200
1. Design
2. Technology
• Main Features
• Hardware and Software
• Service and Maintenance
Page 116
Product features
HumaStar 100 & 200
Wash Station
• 8-step wash cycle
• 2nd cleaning solution
• Level sensors for all containers
• Difference HumaStar 100 vs. 200
• 6 vs. 8 cleaning needles
• Water consumption only 8 ml per test
Page 117
HumaStar 100 & 200
Samples
• Removable sample tray
• Primary tubes and cups
• 60 positions up to 12.5x100 mm
• Optional tray: 20+20 positions up to 16x100 mm
• Internal barcode reader included
Page 118
• HUMAN methods pre-installed and validated
• Substrates, enzymes, turbidimetry, electrolytes
• Open analyzer
• Removable reagent tray
• Reagent cooling
• 30 positions (one used for diluent)
• 4 different reagent vials
HumaStar 100 & 200
Reagents
Page 119
HumaStar 100 & 200
1. Design
2. Technology
• Main Features
• Hardware and Software
• Service and Maintenance
Page 121
Product features
HumaStar 100 & 200
User Interface and Features
Page 122
HumaStar 100 & 200
User Interface and Features
• Easy to use
• Touch screen
Page 123
HumaStar 100 & 200
User Interface and Features
• Easy to use
• Touch screen
• 5 main tabs
• One software -
Complete analyzer line
Page 124
HumaStar 100 & 200
Extensive Information
• Reaction charts
Page 125
HumaStar 100 & 200
Extensive Information
• Reaction charts
• Quality control charts
Page 126
HumaStar 100 & 200
Extensive Information
• Reaction charts
• Quality control charts
• Method statistics
Page 127
HumaStar 100 & 200
LIS
Ext. Computer and LIS
HumaStar
• PC via USB
• ASTM standard
• Bi-Directional
Page 128
HumaStar 100 & 200
1. Design
2. Technology
• Main Features
• Hardware and Software
• Usability and Safety
• Service and Maintenance
Page 129
Product features
HumaStar 100 & 200
Minimum Maintenance
• Monitoring of life time
• Pumps
Page 130
HumaStar 100 & 200
Minimum Maintenance
• Monitoring of life time
• Pumps
• Filters
• Lamp
Page 131
HumaStar 100 & 200
Minimum Maintenance
• Monitoring of life time
• Pumps
• Filters
• Lamp
• Cuvettes
Page 132
• Quality
• High quality components
• High production depth
• Made in Europe
• Extensive testing
• Easy access
HumaStar 100 & 200
Minimum Service
Page 133
HumaStar 100 & 200
Minimum Service
• Quality
• Easy access
• Lamp
Page 134
HumaStar 100 & 200
Minimum Service
• Quality
• Easy access
• Lamp
• Peristaltic pumps
Page 135
HumaStar 100 & 200
Minimum Service
• Quality
• Easy access
• Lamp
• Peristaltic pumps
• Remove top cover
Page 136
HumaStar 100 & 200
Minimum Service
• Quality
• Easy access
• Lamp
• Peristaltic pumps
• Remove top cover
• Remove complete cover
Page 137
HumaStar 100 & 200
Size and Weight
51 kg
76 cm
69 cm
52 c
m
169 cm
Page 138
The end
“Get in the race and ask
for more information
about HumaStar 100
and 200.“
Page 141