6
Multi-Service Access Network The HX9500 SONET/SDH-PDH is a Hybrid Multi-Service Access Multi- plexer with STM-1/4 - OC-3/12 optical lines aggregate and HS tributaries and a non-blocking VC11/VC12/VC3/VC4 cross-connect together with a PDH DS0 cross-connect or DACS with Low Speed tributary modules. The 6U shelf delivers: - 4 High Speed tributary module slots - 6 Low Speed tributary module slots With up to 4 aggregate optical STM- 1/4 - OC-3/12 or electrical STM-1/OC- 3 line interfaces, the HX9500 SONET/ SDH offers service providers a versa- tile protection scheme including UPSR/SNCP and MSP(1+1) protection for both ring and linear network topolo- gies. It can operate with the HX9100 and HX9400 multiplexers in the same topology. The HS tributary modules include opti- cal STM-1/4 - OC-3/12, E3/T3, E1/T1 interfaces and Fast Ethernet over STM-1/4 - OC-3/12. Fast Ethernet sig- nals are mapped into the SONET - SDH payload through standard techniques such as GFP, LAPS, VCAT and LCAS. These HS modules are the same mod- els for the HX9400 SONET-SDH multi- plexer. Version 1.3 August 2012 Features Combined SONET - SDH ADM and E1/T1- PDH multiservice DACS 6U height, full front access (ETSI) shelf TM, ADM and DCS at DS0, VC12, VC3, VC4 Dual STM-1/4 - OC-3/12 Optical Ring Uplinks Hot-swappable cross-connect modules, tributary modules and power modules. Tributary Modules (See Ta- ble1 below) High-Speed or High Density access tributary modules HS Low-Speed access tributary modules (LS) Power Modules DC (-48Vdc) *AC (90 to 240V, 50/60Hz) Dual Power (1+1) Protection Networking protection Tributary protection E1/T1: Card, Port, Line E3/T3: Card, Port, Line B155/622: MSP, SNCP Cross-connect Unit (XCU) SDH Protection MSP, SNCP PDH Protection 1+1 and w 3E1 card SNCP PDH 64K TM, ADM, and cross-connect Full cross-connect at VC11/VC12/VC3/VC4 levels External/Internal/Line timing source with SSM Ethernet supports GFP, LAPS, VCAT and LCAS Full switch Ethernet capabil- ity on EoS card DTMF Engineering Order-Wire using VoIP phone Alarm suppression, masking and report Management Console port, VT100 menu SNMP Port Telnet Centralized management EMS-GUI CXRview CXR’s EMS/iNMS EMS TMN management,full FCAPS end- to end circuit management SSH HX9500 HX9500 HX9500 HYBRID YBRID YBRID SONET/SDH SONET/SDH SONET/SDH-PDH PDH PDH DESCRIPTION The LS tributary modules are connected through a full non-blocking DS0 cross- connect matrix so delivering an inte- grated mini DACS system. All interfaces are fully compliant with the relevant ITU ETSI and ANSI standards. The hybrid SONET/SDH-PDH provides full Operation, Administration, Maintenance and Provisioning (OAM&P) functionalities. Users can easily operate the HX9500R locally or remotely for centralized man- agement together with HX9400R, QX3440/S/D and different product of CXR ranges with CXRview-Plus (EMS) and CXR-iNMS (integrated NMS).

Upload: trannhi

Post on 31-Mar-2018

257 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

Mult i -Ser vice Access Network

The HX9500 SONET/SDH-PDH is a

Hybrid Multi-Service Access Multi-

plexer with STM-1/4 - OC-3/12 optical

lines aggregate and HS tributaries and

a non-blocking VC11/VC12/VC3/VC4

cross-connect together with a PDH

DS0 cross-connect or DACS with Low

Speed tributary modules.

The 6U shelf delivers:

- 4 High Speed tributary module slots

- 6 Low Speed tributary module slots

With up to 4 aggregate optical STM-

1/4 - OC-3/12 or electrical STM-1/OC-

3 line interfaces, the HX9500 SONET/

SDH offers service providers a versa-

tile protection scheme including

UPSR/SNCP and MSP(1+1) protection

for both ring and linear network topolo-

gies. It can operate with the HX9100

and HX9400 multiplexers in the same

topology.

The HS tributary modules include opti-

cal STM-1/4 - OC-3/12, E3/T3, E1/T1

interfaces and Fast Ethernet over

STM-1/4 - OC-3/12. Fast Ethernet sig-

nals are mapped into the SONET - SDH

payload through standard techniques

such as GFP, LAPS, VCAT and LCAS.

These HS modules are the same mod-

els for the HX9400 SONET-SDH multi-

plexer.

Vers ion 1 .3 – August 2012

Features

◦ Combined SONET - SDH ADM

and E1/T1- PDH multiservice

DACS

◦ 6U height, full front access

(ETSI) shelf

◦ TM, ADM and DCS at DS0,

VC12, VC3, VC4

◦ Dual STM-1/4 - OC-3/12

Optical Ring Uplinks

◦ Hot-swappable cross-connect

modules, tributary modules

and power modules.

◦ Tributary Modules (See Ta-

ble1 below) ◦ High-Speed or High Density

access tributary modules HS

◦ Low-Speed access tributary

modules (LS)

◦ Power Modules ◦ DC (-48Vdc)

◦ *AC (90 to 240V, 50/60Hz)

◦ Dual Power (1+1) Protection

◦ Networking protection

◦ Tributary protection ◦ E1/T1: Card, Port, Line

◦ E3/T3: Card, Port, Line

◦ B155/622: MSP, SNCP

◦ Cross-connect Unit (XCU)

◦ SDH Protection MSP, SNCP

◦ PDH Protection 1+1 and w

3E1 card SNCP PDH 64K

◦ TM, ADM, and cross-connect

◦ Full cross-connect at

VC11/VC12/VC3/VC4 levels

◦ External/Internal/Line timing

source with SSM

◦ Ethernet supports GFP, LAPS,

VCAT and LCAS

◦ Full switch Ethernet capabil-

ity on EoS card

◦ DTMF Engineering Order-Wire

using VoIP phone

◦ Alarm suppression, masking

and report

◦ Management ◦ Console port, VT100 menu

◦ SNMP Port

◦ Telnet

◦ Centralized management

EMS-GUI CXRview

◦ CXR’s EMS/iNMS EMS TMN

management,full FCAPS end-

to end circuit management

◦ SSH

HX9500 HX9500 HX9500 HHHYBRIDYBRIDYBRID SONET/SDHSONET/SDHSONET/SDH---PDHPDHPDH

DESCRIPTION

The LS tributary modules are connected

through a full non-blocking DS0 cross-

connect matrix so delivering an inte-

grated mini DACS system.

All interfaces are fully compliant with the

relevant ITU ETSI and ANSI standards.

The hybrid SONET/SDH-PDH provides full

Operation, Administration, Maintenance

and Provisioning (OAM&P) functionalities.

Users can easily operate the HX9500R

locally or remotely for centralized man-

agement together with HX9400R,

QX3440/S/D and different product of

CXR ranges with CXRview-Plus (EMS) and

CXR-iNMS (integrated NMS).

Page 2: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

Page 2 - Multi -Service Access Network Vers ion 1 .3 – August 2012

THE HX9500 R

CXR Web site

www.cxr.com

Specifications may change without notice.

Smart Solutions

for Smart Networks

4 SDH slots

Fans Connector b.dPower

6 PDH slots

The HX9500R structure with two CPU/Aggregate HX9400R-CC5 give it the possibility to deploy

different topologies of SDH aggregates and tributaries. This configuration support 2 SNCP ring

STM1/4 or 2 MSP 1+1 or one SNCP + MSP (1+1) STM1/4 ring with 4 fibers or 4 independent

STM1/4 .

Each interface STM1 or STM4 are independent and can be selected by the selection of optical

module or the settling for multi-rate SFP module.

SDH TOPOPLOGIE OF THE HX9500R

Page 3: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

Page 3 - Multi -Service Access Network Vers ion 1 .3 – August 2012

PDH SDH

COREEDGE ACCESS

EoPDH L2: RSTP L3: Static, RIP, OSPF

EoSDH E-LINE: SNCP LCASE-LAN: RSTP

SNCPMSP 1+1

SNCP+MSP

SNCPMSP 1+1

SNCP MESHSNCP+MSP

1+1SNCP-64K over PDH SNCP-64K over PDH in SDH

HX9500R THE RIGHT PROTECTION FOR PDH and SDH

QX3440QX3440S

HX9400RHX9416R

HX9500R

Page 4: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

Page 4 - Multi -Service Access Network Vers ion 1 .3 – August 2012

CXR Web site

www.cxr.com

Specifications may change without notice.

Smart Solutions

for Smart Networks

894 Faulstich Court

San Jose—CA95112—USA

Phone +1 ( 408 ) 573-2700

Email : [email protected]

Please contact for North America

Rue de l ’ Ornette

28410 Abondant – France

Tel. +33 (0 ) 2 37 62 87 90

Email: [email protected]

and for Europe, Africa

and other countries

SPECIFICATIONS

Physical/Electrical

Clock Source Up to 4 clocks with priority from : Internal, STM-N Line 4 aggregate, 2 External input 2MHz or G704 w or w/o SSM, E1 PDH source, 2 output clocks Management Interface

Alarm Input/Output

Standards Compliance

Certification EMC: FCC Part 15 Subpart B, Class A; EN 55022, Class A; EN55024; EN300 386 * In test for DC48v only: IEC61850-3, IEEE1613 for utilization in electric substation

HX9500R-6U 6U chassis 433mm x 264mm x 223,5mm (W/H/D) HX9x00R-FILTER 0,5U chassis 433mm x 22mm x 223,5mm (W/H/D) HX9x00R-FILTER-CBL-T 2U chassis 433mm x 88mm x 223,5mm (W/H/D) AC Power 90 to 240 VAC, 50/60Hz *

DC 48v Power -36 to –72 Vdc ± 15%

DC 24v Power By use of DC 48v card and a 1U 19” chassis with dual chan-nel converter 24V to 48V the DCDC-2X24-48-300W-1U DC 17 to 31 V to DC 48 V 300W each channel

Temperature -5 to +55°C

Humidity 0-95%RH (non-condensing)

Mounting Desk-top stackable, 19/23 inch rack mountable supply with brackets, and wall mountable

EOW 2 * RJ-11 FXS, for Analog Circuit Telephone Device (Tip/Ring) , including SIPv2 technology

LAN port 2* RJ-45 , Lan ports for SNMP administration, 100BT Console port DB-9F E1/T1 interface connector SCSI-II 68 pins Optical Interface connector SFP module with LC connectors

Number of Optical STM-x Up to 6 STM4 or 10 STM1 Number of E1/T1 channels Card of 16E1/T1, 32 E1/T1 or 63 E1/ 63T1

Console port DB9F, RS232 DCE, user interface VT100 menu driven Standard SNMP V1 and V3 (RFC1213, RFC2571 to RFC2575) OSS interface 10/100BaseT FE (IEEE 802.3u ), Telnet and SSH V2 NE/NE interface DCC/HDLC/Ethernet type II

Inputs Ports 4 Activation current 3 mA Internal resistance 1K Deactivation current 1.5 mA Connectors RJ45 Outputs

Ports 4 Maximum switching voltage 110 Vdc, 125 Vac Initial insul. resist. Min. 100M ohm (at 500Vdc) Connectors RJ45 Use SNMP TRAP or Transmission from Input to Output

ITU-T G.703, G.707, G.751, G.747, G.7041, G.7042, G.775, G.783, G.806, G.813, G.823, G.824, G.826, G.841, G.747, X.86, G.664

ANSI T1.105, T1.107

IEEE 802.1q & 802.1ad(VLAN), 802.1w(RSTP), 802.1s(MSTP), 802.3x(flow control), 802.3u, 802.1p(QoS)

Page 5: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

TRIBUTARY

GROUP

SLOTS TRIB 1 TRIB 2 TRIB 3 TRIB 4 CC4 W CC4 E T1 T2 T3 T4 T5 T6

4 X 155M N/A 2 X 155M N/A

2 x 155M 2 x 155M 1 x 155M 1 x 155M

STM-1/4 STM-1/4

(2 po rts) (2 po rts)

STM-1/4 STM-1/4

(2 po rts) (2 po rts)

STM-1/4 STM-1/4

(2 po rts) (2 po rts)

STM-1/4 STM-1/4

(2 po rts) (2 po rts)

Maxi 252 E1 63 E1 63 E1 63 E1 63 E1

or 126 (1+1) 63 E1 63 E1 (P) 63 E1 63 E1 (P)

Max. 12 E3 3 E3 3 E3 3 E3 3 E3

or 6 (1+1) 3 E3 3 E3 (P) 3 E3 3 E3 (P)

32 FE or 4 GE

w/o protection8 FE or 1 GE 8 FE or 1 GE 8 FE or 1 GE 8 FE or 1 GE 8 FE 8 FE 8 FE 8 FE 8 FE 8 FE

16 FE or 2 GE w

1+1 protection8 FE or 1 GE

8 FE or 1 GE

Protection8 FE or 1 GE

8 FE or 1 GE

Protection

28 FOM w/o

protection7 FOM 7 FOM 7 FOM 7 FOM

14 FOM w 1+1

protection7 FOM

7 FOM

Protection7 FOM

7 FOM

Protection

EoPDH 64k to 2M to 8M per card

Use All QX3440 card 1 and 2 slots

BUS SDH to this 6 PDH

Cards

of 21E1 to 21 VC12

Maximum 6 x 4E1, unique clock

Maximum 3 x 4E1 , unique clock , 1+1 protection

Maximum 6 x 3E1, unique clock , SNCP protection *

Maximum 3 x 3E1, unique clock , 1+1 and SNCP protection

*

No SDH

4 x 2M 4 x 2M 4 x 2M 4 x 2M 4 x 2M 4 x 2M

PDH Tributaries

STM-4STM-4

protection

Link with MSP

(1+1)

2 x STM-12 x STM-1

protection2 x STM-1

2 x STM-1

protection

GLOBAL

PAYLOAD2 x 622M 2 x 622M

Link without

MSP

2 x STM-1 2 x STM-1 STM-1 STM-1

TG 1 TG2 AGGREGATES

STM-4 N/A

HX9500R CAPACITY WITH 2 CC4

Page 5 - Multi -Service Access Network Vers ion 1 .3 – August 2012

HX9500 TRIBUTARY MODULES

High-Speed or High Density Access Tributary Modules (HS) plug-in Interface cards

STM-1/4 - OC-3/12 tributaries

63x ports E1/T1 tributaries

32x ports E1/T1 tributaries

16x ports E1/T1 tributaries

3x ports E3/T3 tributaries

EoS (8xFE+1xGBE) Ethernet card with built in a L2 switch (E-Line/E-LAN)

EoS (8xFE+1xGBE) Ethernet card without switch (E-Line)

The High Speed card are can be used in HX9400R or HX9500R without modification.

Please looks to HX9400R datasheet for tributary specifications.

Low-Speed Access Tributary Modules (LS) plug-in Interface Cards

4x channel E1/T1

3 x channel E1 with SNCP 64K support*

8x channel Dry Contact I/O

8x channel 2W/4W E&M

8x channel G703-64K—Codirectionnal

2x channel G.SHDSL (2 pairs)

4x channel G.SHDSL (1 pairs)

12x channel FXS

12x channel FXO

8x channel OCU-DP

1x or 4x channel C37.94 (low speed optical)

8x port Bridge/Router EoPDH 64Kbps to 2M to 8Mbps

6x channel V.35

6x channel V.36

6x channel X.21

8x channel RS232, 8 RS485 and 8 Bridge RS232

The Low Speed PDH cards are can be used in QX3440/QX3440S or HX9500R without modification.

Please looks to QX3440 datasheet for tributary specifications.

Page 6: HX9500 SDH/SONET & PDH modular multiplexer (En) · SNCP-64K over PDH in SDH HX9500R THE RIGHT PROTECTION FOR PDH and SDH QX3440 QX3440S HX9400R HX9416R HX9500R. Page 4 - Multi-Service

DEFENSE

ELECTRONIC MONEY

POS-BANK

CAMPUS

BUSINESS CENTRE

COMMUNITY

UNIVERSITY

INDUSTRIAL

FACILITIES

AIRPORT

ROAD

SUBWAY

TRAIN

UTILITIES

ELCTRICITY

WATER

GAS

TELCO

www.cxr.anderson-jacobson.com

CXR ANDERSON JACOBSON & CXR LARUS

MANUFACTURES AND SALES EQUIPMENTS FOR

NETWORK ACCESS, TRANSMISSION & TIMING SYSTEM

...AND PROVIDES SOLUTIONS TO HIS CUSTOMERS

DEFENSE - ELECTRONIC MONEY - CAMPUS - INDUSTRIAL - FACILITIES - UTILITIES - TELCO

894 Faulstich Court

San Jose—CA95112—USA

Phone +1 ( 408 ) 573-2700

Email : [email protected]

Please contact for North America

Rue de l ’ Ornette

28410 Abondant – France

Tel. +33 (0 ) 2 37 62 87 90

Email: [email protected]

and for Europe, Africa

and other countries