hygienic design ingles
TRANSCRIPT
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 1/16
R
For use in the design of easy-cleanproduction plant used in open processesin the food and related industries
Rittal – Hygienic Design
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 2/16
2 Rittal Hygienic Design
The Rittal Hygienic Design for food safety is based on:● Machinery Directive
(98/37/EC)Food Machinery sec-tion, Appendix 1, point2.1 (to be replaced by2006/42/EC)
● DIN EN 1672-2:2005Food machinery –General designprinciples – Part 2:Hygiene requirements
● DIN EN ISO 14 159Machine safety –Hygiene requirementspertaining to thedesign of machinery
● Document 13 EHEDG-Guideline to thehygienic design ofapparatus for openprocesses, prepared incollaboration with 3-Aand NSF International
Rittal Hygienic Design pursues four main aims:● Higher productivity through greater system availability● Reducing the amount of cleaning required (faster cleaning,
reduced energy requirements, reduced use of chemicals)● Superior product quality and greater durability by reducing the
contamination risk, which in turn helps to avoid production losses● Improved protection for both consumers and employees
HDRittalHygienic Design
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 3/16
3Rittal Hygienic Design
Cleaning and disinfectionHygiene checks and the moni-toring of cleaning processeshave revealed that the use ofhigh pressures harbours therisk of organic contaminants(fats or proteins) enteringniches and being more widelydistributed. For this reason,
pressures are being signi-cantly reduced.
Decide for yourself what isimportant:● High pressure-resistant
design A labyrinth in front of the sealor multiple screw-fastening
of the lid or door to the enclo-sure, to enable the use ofhigh pressure hosing of upto 120 bar, whether static ormanual.As well as hampering servic-ing, multiple screw-fasteningalso harbours additional
hygiene risks resulting fromincorrectly tightened screwsor damaged seals.
● Hygienic design The new Hygienic Design HDavoids the hollows and deadspaces found in labyrinths forhigh pressure applications.
RITTAL OFFERS THE “KEY” TOOPTIMUM HYGIENE FOR ALLSECTORS!
The completely new lock insert is synonymous with the consistency
of Rittal Hygienic Design. Featuring a high protection category, it
has nowhere for micro-organisms to hide, making cleaning easy.
The same is true of the entire new product line, in every respect.Rittal Hygienic Design reduces the risk of contamination and
signicantly increases productivity.
Meat, poultry, sh,delicatessen products,ready meals
Beverages, fruit andvegetables
Milk processing, cheeseand dairy productmanufacturing
Baked goods andconfectionery
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 4/16
4 Rittal Hygienic Design
Make existing plant more hygienic. Thissaves time with cleaning and disinfection,i.e. downtime is reduced, or plant productiv-ity is increased, provided ...
Optimise existing machines and processesThe growing incidence of food poisoning and foodproduct recalls caused by microbial, physical or chemicalcontamination underscore the need for reliable hygienestandards.
... the wall-mounted devicesand enclosures are installedat a distance for cleaningpurposes. With the wallspacer bracket HD.
… enclosures with cableentry from below aremounted on the new HDbase rather than on a base/plinth or a mounting angleframe.
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 5/16
5Rittal Hygienic Design
... The new HD levelling feet eliminate the need for adjust-ment with external threads.
... The polyamide or brasscable entry with externalthread is replaced by thenew HD stainless steelcable gland .
... the standard at roofsin TS 8 enclosures arereplaced by a slopedattachment .
... Terminal boxes (Premium-KL IP 69K), used e.g. assocket distributors, aremounted on the wall at 45˚ instead of horizontally.
BECOME HEALTHIER, BETTERAND MORE PRODUCTIVE –WITH RITTAL HYGIENIC DESIGN
When it comes to the increasing demands of food safety, stainless
steel enclosures and enclosures in hygienic design are “two different
animals”.
Rittal Hygienic Design offers mechanical engineers and plant opera-tors in the food sector decisive new building-blocks for the hygiene
demands of the future. This innovative sub-range is based on our
world-renowned expertise in enclosure manufacturing and enclosure
climate control.
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 6/16
Hygienic DesignCompact enclosures
6 Rittal Hygienic Design
Enclosure roof tilted forwardsthrough 30˚● Covers the horizontal gap
between the enclosure anddoor
● Overhang edge preventsliquids from running onto theseal
● Sufciently large gap betweenthe overhang edge and thedoor, easy to clean from thefront
● Heat loss dissipation is
encouraged by the largersurface area. This mayeliminate the need for climatecontrol components.
Door ● Chamfered edge fold
prevents liquids fromaccumulating
● With hinges tted inside theseal, i.e. in the enclosure.
Special silicone seal ● Gap-free seal against the
enclosure● High resistance to acids,
alkaline solutions, detergentsand disinfectants.
Mounting plateWith the existing standarddimensions of AE compactenclosuresThe design is a matter ofcustomer preference:● Sheet steel, spray nished● Sheet steel, spray-nished,
resistant to high-pressurecleaning
● Stainless steel● Stainless steel, resistant to
high-pressure cleaning● or the new Hygienic
Design HDOnce project planned, themounting plate remains thesame.
Benets in detail:Enclosure with smooth, gap-freesurface.No additional gaps through:Gland plate with cable entry.● Cable glands are tted
directly in the required sizes
Sealed holes for the wall or oormounting.● Holes for two, three or four
wall spacer brackets may be
drilled where needed● The enclosure may behygienically welded to themachine or plant
Material:Enclosure and door: Stainlesssteel 1.4301 (AISI 304)Mounting plate: Sheet steelLocks:Stainless steel 1.4404
(AISI 316L)Surface nish:Brushed, grain 400, polishedZinc-plated mounting plate
Protection category:IP 66 to EN 605 29/10.91Supply includes:Enclosure of all-round solidconstruction, single door,interchangeable door hinge
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 7/16
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 8/16
Hygienic DesignAccessories
8 Rittal Hygienic Design
HD cable gland, stainless steelSuitable for use in the following areas● Manufacturing and packaging of foodstuffs etc.● Clean room technology (e.g. pharmaceuticals)● Biotechnology● Chemical industryBenets: ● Smooth, solid exterior surfaces effectively
prevent the depositing of harmful micro-organisms. All threads are beneath the cap nut.
● Much easier, therefore cheaper, cleaningcompared with conventional stainless steelcable glands.
● Reliable strain relief, thanks to duplicate cableattachment.
● Resistant to high-pressure cleaning (protectioncategory IP 69K).
Material:Cap nut: Stainless steel 1.4305 (AISI 303)External seals: Made from FDA-approved materialProtection category:IP 68 (5 bar, 30 min.) to EN 60 529/10.91IP 69K to DIN 40 050-9/05.93(Available from November 2007)
12345
6
7
8
External cable sealCompression ringInternal cable sealCap nutGripper jawsClamping ringEnclosure sealBase with locator for
assembly tool
1
2
3
4
5
6
7
8
Critical pointsin conventionalsolutions
Cable entry in frontof sealNo minimum radiion the hexagonExternal threadGap caused byO-ring on theenclosure surface
1
2
3
4
Hygiene-compatibledesign features
Seal directly at thecable entryCompliance withminimum radii onthe hexagonNo external threadFlush terminationbetween the capnut and theenclosure
1
2
3
4
3
4
2
1
3
4
2
1
Why hygiene-compatible cable glands?
Size Cable diametermm Packs of Model No. HD
M12 x 1.5 3 – 6.5 10 2410.000M16 x 1.5 4.5 – 10 10 2410.010M20 x 1.5 6 – 12 10 2410.020M25 x 1.5 11 – 17 10 2410.030
EMC version available on request.
Stainless steel lock nutTo match HD cable glands, stainless steel.Material:Stainless steel 1.4305 (AISI 303)
(Available from November 2007)
Size Packs of Model No. HDM12 x 1.5 10 2410.200M16 x 1.5 10 2410.210M20 x 1.5 10 2410.220M25 x 1.5 10 2410.230
Assembly toolFor HD cable gland, stainless steelFor attaching stainless steel HD cable glands withan external thread or using lock nuts. This can beachieved either from the inside or from the outsideusing a wrench with a hexagonal SW 6 insert.Supply includes:1 set =Adaptor for sizes from M12 – M25.
(Available from November 2007)
Packs of Model No. HD1 set 2410.290
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 9/16
Accessories
Hygienic Design
9Rittal Hygienic Design
HD lock insertsFront-protruding rather than inserted into the doorcreates the best conditions for fast cleaning.Compared with built-in double-bit or alternativelock inserts they present a high hygiene risk.Material:Stainless steel, precision-cast
Supply includes:Cam with insert, or insert only, to be exchangedfor existing systems.
HD enclosure keyFor HD lock insert
HD bitFor universal keySee Innovations 2006, page 180.
Support arm system CP-L,stainless steelIn conjunction with the HD compact enclosureand cable entry from below, this offers the idealsolution for the human/machine interface.The larger diameter provides space to insertseveral cables and/or larger connectors, andsupports greater weights and offers increasedstability when assembling the operating unit.The support section, bent from a single piece,offers ideal hygienic conditions. Furthermore,there are no attachment components or sharp-edged steps on support arm components such aswall/oor mounting, enclosure couplingor enclosure attachment. All seals are external toensure optimum hygiene requirements. For wallmounting from the outside, we recommend anadditional seal and hex screws.
Due to the possibility of condensation forming inthe support arm system as a result of temperatureuctuations, when cleaning and disinfecting theplant we recommend that the support arm shouldbe attached to the bottom of the enclosurewherever possible.
Support section
Size: External diameter: 70 mmWall thickness: 2.9 mmMaterial:Stainless steel 1.4301Surface nish:Brushed, grain 400, polished
Support arm components
Material:Stainless steel 1.4305Supply includes:Assembly parts and seal to the enclosure
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 10/16
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 11/16
Resistant to high-pressure cleaning
Premium Line
11Rittal Hygienic Design
Command Panel
For detailed information,see Catalogue 31, page 274 and 1121.
Dimensionsmm
Supportarm
connectionModel No.
CPWidth Height Depth For installation panelW x H Installation depth
Operatinghousing Keyboardhousing Operatinghousing Operatinghousing Keyboardhousing Operatinghousing KeyboardhousingWith keyboard housing
530 460 200 120
482.6 mm(19˝) x
354.8 mm(8 U)
482.6 mm(19˝) x177 mm(4 U)
115 front 58rear 63 Top 6680.000
530 460 200 120 115 front 58rear 63 Bottom 6680.010
530 460 200 220 215 front 58rear 63 Top 6680.100
530 460 200 220 215 front 58rear 63 Bottom 6680.110
Without keyboard housing
530 360 – 120 482.6 mm(19˝) x310 mm(7 U)
–115 – Top, or
bottom byrotating theenclosure
6681.000
530 360 – 220 215 – 6681.100
To order in stainless steel 1.4404 (AISI 316L) please add the extension XX5X.XXX to the Model No.Delivery times available on request.Other sizes available on request
Command Panel with 17˝ TFTTechnical specications:Resolution max.:17˝: 1024 x 768 pixels,VGA + SXGA non-interlacedColours: 16.2 millionBrightness: 300 cd/m 2 Reading angle: 150° horizontal, 130° verticalContrast ratio: 500 : 1MTBF backlight: 50,000 hVoltage: 12 V DCOn Screen Display (OSD) at rearVGA input: 15 pin D-SubOperating temperature: 0°C to +50°C
Power pack SM 6450.050 and connection cableSM 6450.060, see Cat. 31, page 1047.
Support armconnection
Wmm
Hmm
T1mm
T2mm
Model No.SM
Bottom 530 360 120 70 6450.100Top 530 360 120 70 6450.110
To order in stainless steel 1.4404 (AISI 316L)please use Model No. SM 6450.5XX.Delivery times available on request.
Switch housingStainless steel
Material:1.4301 (AISI 304)Surface nish:Brushed, grain 240Protection category:IP 66 to EN 60 529/10.91Complies with NEMA 4X.
For detailed information,see Innovations 2006, pages 51 and 209.
Dimensionsmm No. of cutouts Model No. SM
Width Height Depth100 100 90 1 2384.010160 100 90 2 2384.020220 100 90 3 2384.030280 100 90 4 2384.040
Version with hygienic lid screws, silicone seal or alternatively without key cut-outs available on request.
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 12/16
Compact enclosures AEResistant to high-pressure cleaning
12 Rittal Hygienic Design
The correct solution in caseswhere high-pressure cleaningis a priority.●
Internal seal protected with a labyrinth fromdirect water jets.● Foamed-in silicone seal● Lock, hinges and mounting plate are all
secured in a vibration-resistant manner.● Solid base, without gland plate● Wall mounting via concealed M8 blind nuts
Protection category:IP 69 K to DIN 40 050-9/5.93Mounting plate: Zinc-plated
Accessories: Internal door, see Cat. 31, page 873.
IP 69 K
Stainless steel, with 10˚ roof slope
Material:1.4301 (AISI 304)
Surface nish:Brushed, grain 240
For detailed information,see Innovations 2006, page 53.
Dimensionsmm Model No. AE
Width Height, front Height, rear Depth230 330 352 155 1101.110400 400 439 250 1101.120400 650 689 250 1101.130650 650 689 250 1101.140
Other sizes available on request.
Sheet steel, spray nished, with straight roof
Material:Sheet steel with aluminium zinc coatingSurface nish:Powder coated in textured RAL 7035
For detailed information,see Catalogue 31, page 121 and 1086.
Dimensionsmm Model No. AE
Width Height Depth230 330 155 1101.010400 400 250 1101.020400 650 250 1101.030650 650 250 1101.040
Other sizes available on request.
KL, BG, AE in stainless steelwith silicone sealIn special ambient conditions, this seal offersgreater, longer-lasting protection againstaggressive detergents and disinfectants. Theclosed cell structure of the foam means that waterabsorption is negligible.Temperature resistance: –40˚C to +130˚C
Terminal boxes KL, stainless steel, Cat. 31,page 270Bus enclosure BG, stainless steel, Cat. 31,page 272Compact enclosures AE, stainless steel, single-door, see Innovations 2006, page 52 and Cat. 31,page 273.With a foamed silicone seal in the l id/door, nowavailable for ordering with extension no..020 = KL and BG in stainless steel 1.4301(AISI 304),.620 = AE in stainless steel 1.4301 (AISI 304).Delivery times available on request.Note:Other sizes, stainless steel 1.4404 or other seriesavailable on request.
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 13/16
Resistant to high-pressure cleaning
Accessories
13Rittal Hygienic Design
Desktop keyboard IP 65Particularly well-suited to all areas with dusty ordamp industrial atmospheres and places wherehygiene is particularly crucial, such as in the foodindustry or medical technology.● Sealed, wipeable surface nish.● High level of mechanical and chemical
resistance to DIN 42 115.● Lenticular key caps and minimal typing force
for optimum nger guidance and fast operation.This makes it ideally suited for workstations wherelarge quantities of data need to be input.Technical specications:Dimensions: 410 x 220 x 25 mm105 keysActuation travel/force: 0.4 mm/2 NService life: ≥ 1 million switching cyclesOperating temperature: –20°C to +70°CGerman layout
Supply includes:
Connection cable with PS/2 connector,length 1.8 m.
Rittal service:Country-specic layout and USB connectionavailable on request.
Model No. SMDesktop keyboard 6446.000
Stainless steel keyboard19˝/4 Ubased on the piezo system.With this innovative technology, merely tappinglightly with your nger is sufcent to initiateswitching. There are no edges, cracks or hollows,as with conventional keyboards. This makes itparticularly suitable for use in the food industry.Technical specications:Dimensions of front panel:482.6 x 177 x 3.7 mmInstallation depth 25 mm105 keysActuation travel/force: 0 mm/0.7 NService life: ≥ 10 million switching cyclesKeypad: Abrasion-resistant electrolyte letteringOperating temperature: –25°C to +55°CPS/2 and USB connectionGerman layoutMaterial:Stainless steel 1.4301 (AISI 304)Protection category:IP 69K to DIN 40 050/5.93Supply includes:Connection cable, length 1.8 m,with PS/2 connector and hex nuts.
Rittal service:Country-specic layout available on request.
464.6
482.6 (19˝)
5
1 5 9
479.6
170
182.3
1 7 4
1 . 5
1 0 4
7
1
32 4
1 7 7 ( 4 U )
Model No. SMStainless steel keyboard 6446.010
Front panel cut-out
SealHoles for fastening boltsContact surface
1
23
4
Pressure relief stopperEspecially when enclosures are exposed tochanging climatic conditions (e.g. with outdoorsiting), condensation may form in sealedenclosures due to pressure differences. Theintegral sealing membrane largely prevents suchpressure differences and hence condensation;additionally, they prevent the ingress of moisturefrom the outside.
Technical specications:● Air permeability up to 120 litres/hour with a
pressure difference of 70 mbar● Protection category IP 66, 68, 69K● Connection thread M12 x 1.5● For tting in wall thicknesses up to 4 mm
Material:PolyamideColour:Similar to RAL 9005 (black)Supply includes:Lock nutFor detailed information, see:www.rittal.com/Moreinfo?2459500
Model No. SZPressure relief stopper 2459.500
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 14/16
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 15/16
A partner for your plant
Liquid cooling concepts
15Rittal Hygienic Design
DCP mounting platePower electronic components can be cooled particularly
effectively using the liquid cooled plate. Heat losses are
cleverly dissipated from the enclosure or housing without
compromising the high enclosure protection category in any
way. Furthermore, liquid cooling is both quiet and a thousand
times more efcient than heat dissipation via air.
The Rittal DCP Cold Plate has received type-tested certication from the TÜV inspectionauthority and is approved for pressures up to10 bar.
y p e T e s t e
3 basic variants are available for the congurationof various power electronic components:
Siemens SINAMICS S 120 series Danfoss frequency converter VLT Automation Drive FC300
1. With drilling surface for thecustomer to drill their owntapped holes (core holemax. 12 mm)
2. With variable wire clampsystem as an accessory forclamping surface: ● All-round● Side● Top and bottom
3. Manufacturer-specicOther sizes and manufacturers available on request.
For detailed information and accessories, see Innovations 2006, from page 129.
RittalDCP CoolingUnitThe CoolingUnit is available intwo variants. As a stand-aloneunit with press-tted coolertubes, or as an add-on in
conjunction with a Rittal ColdPlate. The optional housing forthe cooler ensures even moreefcient air routing and thusreliable cooling of the air insidethe enclosure.
Detailed informationand accessories, see Innovations 2006,from page 133 and also atwww.rittal.com/dcp
DCP CoolingUnit – AddOn
DCP CoolingUnit – Standalone
RittalDCP PanelCoolingThis integrated PanelCoolingsolution was developed byRittal for optimum, space-savingcooling of operating housings.
Heat losses of approx. 150 –350 W can be dissipated withoutthe need for external add-ons.The high protection category ofthe enclosure is retained, thanksto the uid connection at therear of the panel.
Detailed informationand accessories, see Innovations 2006,from page 133 and also atwww.rittal.com/dcp
8/6/2019 Hygienic Design Ingles
http://slidepdf.com/reader/full/hygienic-design-ingles 16/16
R
Small enclosures Compact enclosures Large enclosuresProducts for the human/machine interface Console systemsMaterial: sheet steel, stainless steel, aluminium and plastic
Industrial network technology Input and signalling devicesSolutions for EMC and Ex Cable glands
All in all – solutions from Rittal
Rittal has one of the largest ranges of enclosures availablefor immediate delivery. However, Rittal also supplies inte-grated solutions – up to Level 4. This comprises mechanicalinstallation, power supply, electronic components, climatecontrol and central monitoring. For all of your requirements.
Fully assembled and functional. Wherever in the world youdevelop and implement solutions for yourself and yourcustomers, we are close at hand. The global alliancebetween production, distribution and service guaranteescloseness to the customer. Worldwide!
0 7 / 0 7
E 9 7 3
Electronic packaging
IT Solutions
Communication Systems
System Climate Control
Power Distribution
Industrial enclosures
Rittal GmbH & Co. KG Postfach 1662 D-35726 HerbornTelephone: +49(0)2772 505-0 Telefax: +49(0)2772 505-2319 eMail: [email protected] www.rittal.com