Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY
INSTRUCTIONS for USE of MODERNIZATION SURVEY DATA SHEETS
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
This Modernization Survey Package consists of the following 14 sheets:
1. General InformationOutline of Equipment2.Hoistway Dimensional Data - Elevation3.Hoistway Dimensional Data - Plan / Freight Car4a.Hoistway Dimensional Data - Plan / Passenger Car - Single Slide Doors4b.Hoistway Dimensional Data - Plan / Passenger Car - Two Speed Doors4c.Hoistway Dimensional Data - Plan / Passenger Car - Center Opening Doors4d.Machine Room Layout5.Car Frame Data6.Passenger Hoistway and Car Door Data7.Hoistway Wiring Arrangement8.Signal Fixture Information9.Jack Unit Dimensional Data10.Controller Data11.
PAGE TITLE
WHEN REQUESTING AN ESTIMATE FOR MODERNIZATION WORK:
Complete Pages 1 and 2 with information necessary for the re-spective modernization project
AND
If machine room size or location may be a factor in providingan estimate, complete Page 5 as necessary.
If sling and platform is to be reused, and dimensional informationof existing sling and platform is needed for estimating purposes,then complete Page 6 as necessary.
If new operator equipment is to be provided to fit existing hatchand/or car doors, or if new panels only are to be provided,then complete Page 7 as necessary.
If new fixtures are to be provided to fit within existing boxesor openings, complete Page 9 as necessary.
NOTE: If project is an extensive modernization with equipmentto be installed in an existing hoistway, it is suggested thatPages 3 & 4 be completed at this time.
WHEN MODERNIZATION PROJECT IS BOOKED:
Resubmit Pages 1 and 2 with all necessary informationcompleted (updated).
If CANTON ELEVATOR is to provide elevator layouts, or if mod-ernization is extensive, with new equipment to be installed inexisting hoistway - complete Pages 3, 4, and 5.
If any new machine room equipment is to be furnished, completePage 5.
If existing power unit is to be reused, complete applicablesection of Page 5.
If existing sling and platform is to be reused, and interfaceswith any new equipment, complete Page 6.
If new door operator equipment is to be furnished to attachto existing doors, or if new door panels are to be provided,complete Page 7.
If replacement of, or modification to wiring materials is partof modernization project, complete Page 8.
If new signal fixtures are to be provided to fit within existingboxes or openings, complete Page 9 as necessary.
If a new jack unit or slip casing is to be provided to interfacewith existing equipment, complete Page 10 as necessary. Ifnew jack unit is to be used with the existing power unit,complete the Power Unit section of Page 5.
If a new controller is to be provided, complete page 11.
REMEMBEROUR ABILITY TO MAINTAIN OUR NORMAL HIGH LEVEL OF ENGINEERING
PRECISION IS DEPENDENT ON THE COMPLETENESS AND ACCURACYOF THE INFORMATION SUPPLIED.
AND
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
GENERAL INFORMATION(Complete this page for ALL projects for estimating purposes, and resubmit when sending pages 3 - 11.)
DATE: MATERIAL REQUIRED BY: YOUR NAME:
ELEVATOR COMPANY:
PROJECT:
MATERIAL TO BE SHIPPED TO:
BRIEF DESCRIPTION OFMODERNIZATION WORK
TO BE PERFORMED
WHICH CODE APPLIES:
ELEVATOR DATA(Provide basic information necessary to estimate modernization cost)
QUANTITY: TYPE: PASSENGER FREIGHT CLASS: OTHER (SPECIFY):
ITEM PRESENT REMARKS
DOORS-POWER/MANUAL
CAPACITYSPEED
TRAVEL (FL to FL)
No. of LANDINGSNo. of OPENINGS
FRONT OPENINGS REAR OPENINGS SIDE OPENINGS
PLATFORM SIZEHEIGHT of CAB (INSIDE)
DOOR TYPEOPENING SIZE
CONTROLLER OPERATION
POWER SUPPLYMACHINE ROOM LOCATION
PRIMARY MFGR. OF EXISTING EQPT.:
PRESENT PISTON SIZE: PISTON WALL PRESENT CYLINDER SIZE:NOTE:
PRESENT CAR WT. PRESENT GROSS WT.(IF AVAILABLE) (IF AVAILABLE)
OR DESCRIPTION OF CAR
(IF AVAILABLE) :
ADDITIONAL REMARKS:
: :
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOVE
YOU S
COOB
Y
NEWIF SAME AS PRESENT, INDICATE
BY A CHECK ( )
*
**
**
HOISTWAY SIZE*PIT*
OVERHEAD*
PISTON AND CYLINDER SIZES CAN BE GIVEN EITHER AS DIAMETERS OR AS CIRCUMFERENCES (DISTANCE AROUND). TO OBTAIN A CIRCUMFERENCE DIMENSION, WRAP A TAPEMEASURE TIGHTLY AROUND THE PISTON OR CYLINDER AND READ TO 1/16 OF AN INCH. IF SUPPLYING A CIRCUMFERENCE DIMENSION, INDICATE IT AS SUCH BY WRITING "CIR" AFTER THE MEASUREMENT.
WHEN PROJECT IS BOOKED, ACCURATE FIELD MEASUREMENTS OF EXISTING CONDITIONS WILL BE REQUIRED, IF THIS DATA IS NECESSARY TO COMPLETE ENGINEERING. SEE PAGES 3 - 11.
@@@
*
MACHINE ROOM DOOR OPENING WIDTH (IF APPLICABLE) ANY OTHER OPENINGS OR OBSTRUCTIONS THAT WOULD
LIMIT ACCESS? DESCRIBE:
H.P. OF EXISTING POWER UNIT: TYPE OF POWER UNIT: BELT DRIVE DIRECT DRIVE SUBMERSIBLE
*
PHONE:
FAX:
Page 1
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
OUTLINE of EQUIPMENT(Complete this page for ALL projects for estimating purposes)
REMARKS
ADDITIONAL (or New cab desc.):
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
COMPONENT
N/A –
NEW.REPAIR ORREFURBISH.REUSE.
N –R –
–NOT APPLICABLE.
POWER UNITINCLUDE:
JACK UNIT
PIT SUPPORTSPRING BUFFERSCONTROLLERMOTOR STARTERLEVELING SWITCHES, VANES & BRACKETSFLOOR SWITCHES, CAM & BRACKETSLIMIT SWITCHES, CAM & BRACKETSHOISTWAY WIREWAY - (CONDUIT)TRAVELING CABLEHATCH WIRINGSLINGPLATFORMCAR ENCLOSURE
FIXTURES
PIT STOP SWITCHCROSSHEAD INSPECTION STATION
HOISTWAY ENTRANCE FRAMES, SILLS, STRUCTURAL, FACIA
HOISTWAY DOOR PANELS
DOOR OPERATOR EQUIP.
PHOTO EYE OR PROXIMITY DEVICERAILSRAIL BRACKETSOIL LINE MATERIALSSHUT OFF (GATE) VALVELAYOUTS REQUIRED
MISC. (DESCRIBE)
MUFFLER HEATER VALVE ONLY
INCLUDE: HEAD BEARING PISTON ONLYCYLINDER ONLY
IF PARTIAL REPLACEMENT, OR IF ADDITIONAL FIXTURES ARETO BE FURNISHED, MARK "PARTIAL" OR "ADDITIONAL" AT LEFTAND DESCRIBE REQUIREMENTS IN REMARKS COLUMN AT RIGHT.
IF PARTIAL REPLACEMENT, MARK "PARTIAL"AT LEFT AND DESCRIBE IN REMARKS COLUMNAT RIGHT.
IF ADDITIONAL, MARK "ADDITIONAL" AT LEFT ANDDESCRIBE IN REMARKS COLUMN AT RIGHT.
FOR FREIGHT CAR(S) ONLY
BUMPER RAILSRETIRING CAMCAR GATES
REMARKS
TO FIT WITHIN EXISTING BOXES OR CUTOUTS (SEE PAGE 9).
SIGNAL FIXTURE VOLTAGE:
EXISTING OPERATOR MFGR & TYPE:
IF NEW, DESCRIBE BELOW
IF NEW, WHAT IS EXISTING WALL CONSTRUCTION?
Page 2
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
HOISTWAY DIMENSIONAL DATA - ELEVATION
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
BUFF
ERH
EIG
HT
STR
OKE
IF E
XIST
ING
BU
FFER
SAR
E TO
BE
REU
SED
CO
MPL
ETE
THIS
INFO
IF E
XIST
ING
SLI
NG
IS T
O B
ER
EUSE
D S
EE S
HEE
T 6
FOR
DIM
ENSI
ON
S R
EQU
IRED
INDICATE AND
OVERHEADOBSTRUCTIONS
CLE
ARAN
CE
FRAM
E O
PEN
ING
HEI
GH
T
CLE
AR O
VER
HEA
D
F.O
.H.
FLO
OR
to F
LOO
R T
RAV
ELPI
T D
EPTH
PLATFORM LEVEL WITH FLOOR
I LOV
E EE
IF EXISTING JACK UNIT IS TO BEREUSED INDICATE –
TOP RUNBY
BOTTOM RUNBY
(Complete this page if elevator layouts are to be provided by Canton - or if new basicelevator equipment is to be provided to fit within existing hoistway.)
(This information is required when project is booked.)
DIMENSION ANY
IND
ICAT
E AN
DD
IMEN
SIO
N A
NY
HO
ISTW
AYO
BSTR
UC
TIO
NS
DIM
ENSI
ON
F.O
.H.
ATFR
ON
TR
EAR
REA
RFR
ON
T
WAL
LTH
KNS/
CONS
.TH
KNS/
CONS
.W
ALL
FLO
OR
DESI
GNAT
ION
OPE
NIN
GAT
REA
RFR
ONT
FLO
OR
TOFL
OO
RD
IMEN
SIO
N
**
IF NE
W FR
AMES
ARE
TO B
E PR
OVID
ED - T
HEN
INDI
CATE
WAL
L THI
CKNE
SS AN
DCO
NSTR
UCTIO
N AT
EAC
H OP
ENIN
G:M
= MAS
ONRY
C =
CONC
RETE
G =
DRYW
ALL (
GYP)
ADDI
TIONA
LRE
MARK
S:
*
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 3
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
HOISTWAY DIMENSIONAL DATA - PLAN
I LOV
E EE
(Complete this page if elevator layouts are to be provided by Canton - or if new basicelevator equipment is to be provided to fit within existing hoistway.)
(This information is required when project is booked.)
(FREIGHT CAR HOISTWAY)
FLOOR
F.O.W.FRONT A B C D E F G H J K L M NF.O.W.
REAR
REARF.O.W. NMLKJHGFEDCBAFRONT
F.O.W.
TABLE 2(COMPLETE SURVEY)
TABLE 1(MINIMUM CONTROLLING DIMENSIONS)
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
If minimum controllingdimensions are easilydetermined and reliablydefine the hoistway, thenonly TABLE 1 need becompleted. If, however,the condition of thehoistway (plumbness,alignment, etc.) is lessthan perfect, or if acomplete survey is de-sired, fill out TABLE 2.
Remember - our abilityto maintain our normalhigh level of engineeringprecision is dependenton the completenessand accuracy of thedimensional informationsupplied.
IF EXISTING OPENINGFRAMES ARE TO BE REUSEDDIMENSION F.O.W. MUSTBE FILLED IN FOR ALLOPENINGS.
HOISTWAY WIDTH IN PIT
FRONT OPENINGS
A B
F.O.W.FRAME OPENING WIDTH (FRONT)
CPLUMB
LINE*
ED
PLAT
FOR
M
PLATFORM
BETWEEN GUIDES
K J
G
H
REAR OPENINGS
F.O.W.FRAME OPENING WIDTH (REAR)
NM
HO
ISTW
AY D
EPTH
IN P
IT
F
L
FAC
E
EXISTING GUIDE RAILS (IF REUSED)ARE:
#/ftOR DIMENSION BELOW
INDICATE AND DIMENSION ANY OBSTRUCTIONS IN HOISTWAY
If car gate(s) will be reused - sketchand dimension gate and post locationsand projections:
Indicate cam and door lock, hall station, andCOP location if applicable.
Inclusion of dimensions & isnot essential, but is recommended onany modernization project where existinghatch is used and where any out of plumbconditions, or out of line conditions ofentrances may affect new installation.
* A, B, C
@
@
REQUIRED FOR REAR OPENING ONLY
REQUIRED FOR REAR OPENING ONLY
TYPE OF DOORS
TYPE OF DOORS
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 4a
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATAHOISTWAY DIMENSIONAL DATA - PLAN
I LOV
E EE
(Complete this page if elevator layouts are to be provided by Canton - or if new basicelevator equipment is to be provided to fit within existing hoistway.)
(This information is required when project is booked.)
(PASSENGER CAR HOISTWAY)
FLOOR
F.O.W.FRONT A B C D E F G H J K L M NF.O.W.
REAR
REARF.O.W. NMLKJHGFEDCBAFRONT
F.O.W.
TABLE 2(COMPLETE SURVEY)
TABLE 1(MINIMUM CONTROLLING DIMENSIONS)
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
HOISTWAY WIDTH IN PIT
FRONT OPENINGS
A B
F.O.W.FRAME OPENING WIDTH (FRONT)
C
PLUMBLINE
*
ED
PLAT
FOR
M
PLATFORM
BETWEEN GUIDES
K J
G
H
REAR OPENINGS
FRAME OPENING WIDTH (REAR)
HO
ISTW
AY D
EPTH
IN P
IT
F
L
FAC
E
EXISTING GUIDE RAILS (IF REUSED)ARE:
#/ftOR DIMENSION BELOW
INDICATE AND DIMENSION ANY OBSTRUCTIONS IN HOISTWAY
Inclusion of dimensions & isnot essential, but is recommended onany modernization project where existinghatch is used and where any out of plumbconditions, or out of line conditions ofentrances may affect new installation.
* A, B, C
@
@
REQUIRED FOR REAR OPENING ONLY
Indicate hall station, and COP location if applicable.
(SINGLE SLIDE DOORS)
F.O.W.M N
REQUIRED FOR REAR OPENING ONLY
RCR1 RCR2
RCR1 RCR2
RC1 RC2
RC2RC1
RCR2 RCR1
RC1RC2
If minimum controlling dimensions are easilydetermined and reliably define the hoistway,then only TABLE 1 need be completed. If,however, the condition of the hoistway (plumb-ness, alignment etc.) is less than perfect, orif a complete survey is desired, fill out TABLE 2.
Remember - our ability to maintain our normalhigh level of engineering precision is dependenton the completeness and accuracy of thedimensional information supplied.
IF EXISTING OPENING FRAMES ARE TO BE REUSEDDIMENSION F.O.W. MUST BE FILLED IN FOR ALLOPENINGS.
AS SHOWNOPPOSITE
DOORS
DOORS
OPPOSITEAS SHOWN
SILL
PSILL
P
P
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 4b
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATAHOISTWAY DIMENSIONAL DATA - PLAN
I LOV
E EE
(Complete this page if elevator layouts are to be provided by Canton - or if new basicelevator equipment is to be provided to fit within existing hoistway.)
(This information is required when project is booked.)
(PASSENGER CAR HOISTWAY)
FLOOR
F.O.W.FRONT A B C D E F G H J K L M NF.O.W.
REAR
REARF.O.W. NMLKJHGFEDCBAFRONT
F.O.W.
TABLE 2(COMPLETE SURVEY)
TABLE 1(MINIMUM CONTROLLING DIMENSIONS)
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
HOISTWAY WIDTH IN PIT
FRONT OPENINGS
A B
F.O.W.FRAME OPENING WIDTH (FRONT)
C
PLUMBLINE
*
ED
PLAT
FOR
M
PLATFORM
BETWEEN GUIDES
K J
G
H
REAR OPENINGS
FRAME OPENING WIDTH (REAR)
HO
ISTW
AY D
EPTH
IN P
IT
F
L
FAC
E
EXISTING GUIDE RAILS (IF REUSED)ARE:
#/ftOR DIMENSION BELOW
INDICATE AND DIMENSION ANY OBSTRUCTIONS IN HOISTWAY
Inclusion of dimensions & isnot essential, but is recommended onany modernization project where existinghatch is used and where any out of plumbconditions, or out of line conditions ofentrances may affect new installation.
* A, B, C
@
@
REQUIRED FOR REAR OPENING ONLY
Indicate hall station, and COP location if applicable.
(TWO SPEED DOORS)
F.O.W.M N
REQUIRED FOR REAR OPENING ONLY
RCR1 RCR2
RCR1 RCR2
RC1 RC2
RC2RC1
RCR2 RCR1
RC1RC2
If minimum controlling dimensions are easilydetermined and reliably define the hoistway,then only TABLE 1 need be completed. If,however, the condition of the hoistway (plumb-ness, alignment etc.) is less than perfect, orif a complete survey is desired, fill out TABLE 2.
Remember - our ability to maintain our normalhigh level of engineering precision is dependenton the completeness and accuracy of thedimensional information supplied.
IF EXISTING OPENING FRAMES ARE TO BE REUSEDDIMENSION F.O.W. MUST BE FILLED IN FOR ALLOPENINGS.
AS SHOWNOPPOSITE
DOORS
DOORS
OPPOSITEAS SHOWN
SILL
PSILL
P
P
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 4c
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATAHOISTWAY DIMENSIONAL DATA - PLAN
I LOV
E EE
(Complete this page if elevator layouts are to be provided by Canton - or if new basicelevator equipment is to be provided to fit within existing hoistway.)
(This information is required when project is booked.)
(PASSENGER CAR HOISTWAY)
FLOOR
F.O.W.FRONT A B C D E F G H J K L M NF.O.W.
REAR
REARF.O.W. NMLKJHGFEDCBAFRONT
F.O.W.
TABLE 2(COMPLETE SURVEY)
TABLE 1(MINIMUM CONTROLLING DIMENSIONS)
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
HOISTWAY WIDTH IN PIT
FRONT OPENINGS
A B
F.O.W.FRAME OPENING WIDTH (FRONT)
C
PLUMBLINE
*
ED
PLAT
FOR
M
PLATFORM
BETWEEN GUIDES
K J
G
H
REAR OPENINGS
FRAME OPENING WIDTH (REAR)
HO
ISTW
AY D
EPTH
IN P
IT
F
L
FAC
E
EXISTING GUIDE RAILS (IF REUSED)ARE:
#/ftOR DIMENSION BELOW
INDICATE AND DIMENSION ANY OBSTRUCTIONS IN HOISTWAY
Inclusion of dimensions & isnot essential, but is recommended onany modernization project where existinghatch is used and where any out of plumbconditions, or out of line conditions ofentrances may affect new installation.
* A, B, C
@
@
REQUIRED FOR REAR OPENING ONLY
Indicate hall station, and COP location if applicable.
(CENTER OPENING DOORS)
REQUIRED FOR REAR OPENING ONLY
RCR1 RCR2
RCR1 RCR2
RC1 RC2
RC2RC1
RC1RC2
If minimum controlling dimensions are easilydetermined and reliably define the hoistway,then only TABLE 1 need be completed. If,however, the condition of the hoistway (plumb-ness, alignment etc.) is less than perfect, orif a complete survey is desired, fill out TABLE 2.
Remember - our ability to maintain our normalhigh level of engineering precision is dependenton the completeness and accuracy of thedimensional information supplied.
IF EXISTING OPENING FRAMES ARE TO BE REUSEDDIMENSION F.O.W. MUST BE FILLED IN FOR ALLOPENINGS.
SILL
PSILL
P
P
NF.O.W.M
RCR2 RCR1
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 4d
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
MACHINE ROOM LAYOUT
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(This information is required when project is booked.)
(Complete this page when location of machine room or equipmentin machine room is a factor in modernization effort.)
D
C
B
A
INDICATE - HOISTWAY ADJACENT TO SIDE: or REMOTEA B C D(indicate below)
Indicate location of door opening and swing, andclear width of opening between stops.
Indicate location of disconnect switch and otherexisting equipment (power unit, controller(s),motor starter, etc.) if applicable.
Show any obstructions.
If applicable, show existing oil line location andsize.
Show existing electrical conduit run to hatch –location and size.
Is silencer in place? Indicate location.
Is silencer to be reused?
Is existing disconnect switch to be reused?
Existing disconnect switch is amps.
Is machine room temperature controlled?
Clear height of machine room.
IF MACHINE ROOM IS REMOTE FROM HOISTWAY, SKETCH ANDDIMENSION THE RELATIONSHIP BETWEEN MACHINE ROOM AND HOISTWAY.
POWER UNITIf power unit is to be reused, complete thefollowing:
TANK: Usable oil capacity
MOTOR: H.P.
Voltage
F.L.A.
PUMP: G.P.M.
VALVE: Mfg./Model
Size (if applicable)
Coil Voltage
ADDITIONALREMARKS
SYSTEM STATIC PRESSURE Empty Car: P.S.I.
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
MACHINE ROOM IS @ LOWEST LANDING SERVED
PIT FLOOR LEVELOTHER FLOOR LEVEL, DESCRIBE–
Page 5
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
CAR FRAME DATA
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(This information is required when project is booked.)
(Complete this page when existing sling & platform is to be reused,and if dimensional information is necessary for modernization effort.)
PLAT
FOR
M to
UN
DER
SID
Eof
CR
OSS
HEA
D
CROSSHEAD CHANNELS
WIDTH FLANGEX
SIDE STILE
WIDTHX
FLANGE
BOLSTER CHANNELS
WIDTHX
FLANGE
BUFFER STRIKE PLT
THKNS
PLATFORM THKNS
CROSSHEAD
SIDE STILE
~GUSSET
IF SLING ISGUSSETTED
PROVIDE
PLATFORM (IF TO BE REUSED, DESCRIBE CONSTRUCTION):
TYPE OF FLOORING:
IS PLATFORM SOUND ISOLATED?
GUIDE SHOES: NEW REUSE
TYPE:
IF NEW GUIDE SHOES ARE TO BE FURNISHED, SHOWMOUNTING ARRANGEMENT IF APPLICABLE.
INCLUDE ANY OTHER INFO PERTINENT TO SLING & PLATFORM:
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 6
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
PASSENGER HOISTWAY and CAR DOOR ARRANGEMENT
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(Complete this page if existing hoistway entrances and/or car doors areto be reused - with new operator equipment and/or new door panels to be provided.)
(Complete this page for estimating purposes when job is booked unless new equipment is to be identical to original,or if you are confident that existing space limitations are sufficient to adapt new equipment.)
PLATFORM
(TWO SPEED SHOWN)
A
B
FACE OF DOOR TOEDGE OF PLATFORM
CD
FLOOR A
HOISTWAY SILL
EF
GH {TWO SPEED
ONLY
{TWO SPEEDONLY
PLATFORM SILL
DOOR PANELWIDTH-HOISTWAY
DOOR PANELWIDTH (CAR)
B C D E F G H
IF DIMENSIONS FOR ALL FLOORSARE IDENTICAL, ONLY FILL IN ONCE
(If dimensions for all floorsare identical, only fill in once.)
X YFOR CENTER
OPENING ONLY
YXYXFLOORREARFRONT
REMARKS:
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 7
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
HOISTWAY WIRING ARRANGEMENT
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(This information is required when project is booked.)(Complete this page if replacement of, or modification to wiring materials is required for this project.)
FRONT
HATCH SWITCHES - NUMBER, TYPE, AND CONTACTS (N.O. or N.C.):
TERMINALS
INTERMEDIATE
@
@
IS DOOR ZONE SWITCH INCLUDED:
DOES PRESENT JOB HAVE:CAR TOP INSPECTION SWITCH
PIT STOP SWITCH
IF THE POSSIBILITY OF REUSING TRAVEL CABLE EXISTS, INDICATE THENUMBER OF WIRES OF THE CURRENT TRAVEL CABLE
SKETCH PRESENT LOCATION AND SIZE OF WIRING MATERIALS AND DEVICESTHAT ARE TO BE REUSED. INDICATE LOCATION OF HALL AND CAR STATIONS.
REMARKS
LEVELING SWITCHES ON CAR - NUMBER, TYPE & CONTACT (N.O. or N.C.)
PAIRS OF PHONE WIRES:
IF POSSIBLE, SHOW ANY OBSTRUCTIONS OR VARIATIONS IN HATCH THATWOULD AFFECT MODERNIZATION. INDICATE RIGHT OR LEFT HAND WIREWAY/CAR TOP BOX REQUIRED. INDICATE ON PAGE 5 OF THIS SURVEY THE RE-LATIONSHIP BETWEEN THE MACHINE ROOM AND THE HOISTWAY.
RIGHT
LEFT RIGHT
LEFT
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 8
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
SIGNAL FIXTURE INFORMATION
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(Complete this page if modernization project requires new fixtures to be installed in existing openings or boxes.)(This information is required when project is booked or if required for estimating purposes.)
CAR
HALL
IF SIDEWALL COP,INDICATE ANY
OBSTRUCTIONSIN HOISTWAY
IF SIDEWALL COP,DO BRACE RODS
INTERFERE ?
COP
CDICPI
CPI CDICOP
CO
P
HALLLANTERN
HALLSTATION
STATIONHALL
HALL P.I. ORP.I. & LANTERNCOMBINATION
EXISTING OPENINGS OR BOXES TO BE REUSED:Car Operator Panel
Car Position IndicatorCar Direction Indicator
Fire Switch present
Indicate the dimensions of the openings orboxes as applicable.
REMARKS
Fire Switch present
Hall LanternHall Position Indicator
Hall Station
EXISTING OPENINGS OR BOXES TO BE REUSED:
Access Switch present
Indicate the dimensions of the openings or boxes as applicable.If opening sizes are not identical between all floors, indicate diff-erences in the remarks section below.
REMARKS
ALL DIMENSIONS ARE TO BE CUTOUT OR BOX SIZES
IF SO, INDICATEHOW & WHERE
ALTERNATE
LOCATION
Hall P.I. and Lantern Comb.
HALL P.I. ORP.I. & LANTERNCOMBINATION
HALLSTATION
ALTERNATELANTERN
OR
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
Page 9
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
JACK UNIT DIMENSIONAL DATA
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(Complete this page if jack unit is to be replaced, or if slip casing is to be provided for existing jack.)(This information is required when job is booked.)
TOP FLOOR
BOTTOM FLOOR
PIT CHNLHEIGHT IFEXISTING
BETWEEN PIT CHNLIF EXISTING
FLO
OR
TR
AVEL
PIT
DEP
TH
(FO
R S
LIP
CAS
ING
, SU
PPLY
DIM
ENSI
ON
TO B
OTT
OM
INSI
DE
OF
CYL
IND
ER IF
PO
SSIB
LE)
PLATFORM &BOLSTER
PLATEN
O.D. PISTON
O.D. CYLINDER
TO T
OP
OF
HEA
D
TO O
UTL
ET C
L
EXISTING OUTLET
SIZE x LONG
CONNECTION:GROOVED THREADED
OTHER
ORIENTATION IN PIT:FRONT/REAR SIDE
TRAVEL ABOVE TOP FLOOR TRAVEL BELOW BOTTOM FLOOR
REMARKS
IF A COMPLETE NEW JACK UNIT IS TO BE PROVIDED FOR USEWITH AN EXISTING POWER UNIT, COMPLETE THE POWER UNIT
SECTION OF THIS SURVEY (PAGE 5).
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
EXISTING HYDRAULIC CYLINDER I.D.(FOR SLIP CASING OR NEW CYLINDER
TO FIT INSIDE EXISTING CYLINDER)
(FULLY COLLAPSED JACK) (PISTON EXTENDED TO STOP)
I LOV
E SCO
OBY
Page 10
Canton Elevator Inc.HYDRAULIC ELEVATOR
MODERNIZATION SURVEY DATA
CONTROLLER DATA
2575 GREENSBURG ROAD NORTH CANTON, OHIO 44720 PHONE (330) 833-3600 FAX (330) 833-0229
I LOV
E EE
(Complete this page if a new controller is to be furnished.)(This information is required when project is booked, or if needed for estimating purposes.)
GENERAL
Number of elevatorsType: Passenger Freight Other
Hydro Traction
OPERATION
Constant pressureSingle automatic Call & sendCollectiveSelective CollectiveDuplex TriplexOtherMicroprocessor Relay logic
POWER, MOTOR, & VALVE DATA
Volts Phase HzHP F L AmpsValve Valve coilsX-Line startY-Delta startStaggered start
DOORS
Door operator Mfgr TypeSelective door operationDoor nudgingDifferential Car/Hall Door TimePhoto eyesTimed photo eye cutoutRetiring Cam by Front Rear VoltageOther
REMARKS
SWITCHES
Leveling switches and vanesIntermediate floor hatch switchesFloor selector byOther
SIGNALS
Signal voltageCall register lightsIn use lightsCar P.I. Direction arrows Passing floor gongHall P.I. Direction arrowsCar direction indicator Handicap gongHall Lantern Handicap gong Programmer byDoor open bellUp run bellCar arrival lights GongOther
ADDED FEATURES
Top of car inspectionIn car inspection switchFire service phase Car key switch: 2 position 3 Position Main floor return Alternate floorIndependent serviceAttendant serviceU.L. LabelReverse phase relayAccess switches: Top BottomLoad weight device By-passEmergency power Return to & shut down, or Car runs on emergency powerBattery operated rescue unitSpecial cabinet Describe:
Hospital service
REMARKS
@
@
@
Low oil connections for pressure switch
NOTE: WHEN SENDING PAGES 3 THROUGH 11, PLEASE RESUBMIT A COMPLETED PAGE 1.
I I & II Other than ANSI
Dig. Std.
Std.Dig.
Page 11