ibm systems & technology group ibm storwize family peter lončarević phone: +386 1 33862617,...
TRANSCRIPT
IBM Systems & Technology Group
IBM Storwize Family
Peter LončarevićPhone: +386 1 33862617, Mobile: +386 40456617, E-mail: [email protected]
IBM Systems & Technology Group
© 2012 IBM Corporation2 Storwize Family
Agenda
Introduction
Strowize V3700
Storwize V7000
Storwize Flex V7000
Advanced features
IBM Systems & Technology Group
© 2012 IBM Corporation3 Storwize Family
Expanding the Storwize Family
• same CLI• same user interface• one set of functions (selectively licensed)• one code base on all platforms
IBM Systems & Technology Group
© 2012 IBM Corporation4 Storwize Family
IBM Introduced a New Era in Midrange Disk Systems
IBM Storwize V7000 announced October 7, 2010• Very well-received by customers, business partners and reviewers
• Tremendous positive reception around the world
• Presence in every major country and industry
Over 13.200 systems sold world-wide since Nov 2010 GA (Sep 2012)
One of the fastest product ramps in IBM storage history
There have been numerous attempts at repackaging high-end enterprise products for a
wider audience, but few get it right. One exception, however, could be IBM’s new Storwize V7000,
which mixes enterprise-class storage virtualization with custom hardware and an intuitive
management interface to create a highly scalable, yet easy-to-deploy, mid-range storage solution.
Source: Talk on the Street
… Author Alan Stevens gives his review, February 24, 2011 (Extract)
IBM Systems & Technology Group
© 2012 IBM Corporation5 Storwize Family
Built on Proven IBM Technologies
IBM SVC• Storage virtualization• Global & Metro Mirror• FlashCopy• Thin provisioning• Volume mirroring
XIV Storage• Innovative easy to use
graphical user interface
DS8000 Family• RAID 0,1,5,6,10
capabilities • Easy Tier
‒ Built on proven IBM storage technologies
‒ Widest range of external storage virtualization support available
IBM Storwize V7000
SONAS*• File services• Remote copy• File snapshots• ILM with HSM• Quotas
* These capabilities are part of Storwize V7000 Unified
IBM Systems & Technology Group
© 2012 IBM Corporation6 Storwize Family
Agenda
Introduction
Strowize V3700
Storwize V7000
Storwize Flex V7000
Advanced features
IBM Systems & Technology Group
© 2012 IBM Corporation7 Storwize Family
What is Storwize V3700 ?
Storwize V3700 is an entry level storage controller
1Gb/s iSCSI host attachment
Optional: 10Gb/s iSCSI, 8Gb FC, FCoE
Internal virtualization gives access to advanced functions
– thin provisioned volumes, flash copy, mirroring
SAS network for expansion (up to 4 expansion enclosures)
Internal drives
– SSD, 15K SAS, 10K SAS and NL SAS
– supports up to 120 x 2.5”, 60 x 3.5”
Customer installable and maintainable
IBM Systems & Technology Group
© 2012 IBM Corporation8 Storwize Family
Controller Enclosure – Rear
Looks identical on type 12C and 24C
Rear of the Enclosure:
– There are two power supply slots along the bottom of the unit, each taking up half of 1U. The left hand slot is power supply 1, the right hand slot is power supply 2. The power supplies are inserted the same way up (unlike V7000).
– There are two canister slots along the top of the unit, again taking up half of 1U The left slot is canister 1, the right slot is canister 2. The canisters are inserted the same way up (unlike V7000)
– Fans are contained within the PSU, replacement requires a new PSU
– Fan speed is variable and under system control
– Fans continue to operate in a PSU which has failed or lost AC power
IBM Systems & Technology Group
© 2012 IBM Corporation9 Storwize Family
Four 6 Gb/s SAS ports
– currently only port 4 is used (foradditional enclosure connections)
Two USB 2.0 ports
– one port used during install
Two 10/100/1000 Mb/s Ethernet ports
– Usage of port 1 is required, port 2 is optional
Optional Host Interface Cards
Node Canister
IBM Systems & Technology Group
© 2012 IBM Corporation10 Storwize Family
Node Canister
Intel Sandy Bridge architecture
– Dual core Celeron G530T
– CPU runs in energy saving Green Mode
4GB memory per node canister ( 8GB total )
– optional upgrade to 8GB per node canister ( 16GB total )
Battery Backup Unit (BBU) inside node
Option to install Host Interface Card (HIC)
Battery
Memory
CPU
Host InterfaceCard (HIC)
IBM Systems & Technology Group
© 2012 IBM Corporation11 Storwize Family
SAS Network
Unlike V7000, V3700 node canister only has 1 SAS chain
V3700 supports up to four expansion enclosures
Node canisters use SAS port 4 for expansion connection
only V3700 expansion enclosures are supported(no V7000)
IBM Systems & Technology Group
© 2012 IBM Corporation12 Storwize Family
Vendor Size Type
Seagate 146GB/300GB 2.5” 15K HDD
Toshiba 146GB/300GB 2.5” 15K HDD
Hitachi 300GB/600GB/900GB 2.5” 10K HDD
Toshiba 300GB/600GB/900GB 2.5” 10K HDD
Seagate 500GB/1TB 2.5” 7.2K Nearline HDD
Seagate 2TB/3TB 3.5” 7.2K Nearline HDD
Hitachi 2TB/3TB 3.5” 7.2K Nearline HDD
Hitachi 200GB/400GB 2.5” SDD
Only V3700 drives can be used in V3700Drive types can be mixed within an enclosure
Supported Drives
IBM Systems & Technology Group
© 2012 IBM Corporation13 Storwize Family
Comparing Storwize V3700 and DS3500
IBM Systems & Technology Group
© 2012 IBM Corporation14 Storwize Family14
– Easy-to-use, embedded graphical user interface
– Thin provisioning capabilities: allocate the exact amount o
space needed at the time it is required
– Non-disruptive migration from existing FC storage helps
speed implementation and minimize disruption
– Sophisticated data protection with FlashCopy technology
– Multi-protocol support (iSCSI, FC and FCoE and SAS1),
provides consolidation flexibility
– Full interoperability: extensive suite of Microsoft and
VMware solutions supported
Summary of Storwize V3700 system
Easy to manage and efficient entry storage system designed to address growing data requirements and server consolidation needs
1 Statement of Direction. IBM Plans are subject to change without notice
IBM Systems & Technology Group
© 2012 IBM Corporation15 Storwize Family
Agenda
Introduction
Strowize V3700
Storwize V7000
Storwize Flex V7000
Advanced features
IBM Systems & Technology Group
© 2012 IBM Corporation16 Storwize Family
IBM Storwize V7000 – The Right Solution
Enterprise capability at a midrange price
Scalable as your needs grow
Provides high storage efficiency
Breakthrough ease of use increasing administrator efficiency
Comprehensive integrated software functions
IBM Systems & Technology Group
© 2012 IBM Corporation17 Storwize Family
Expansion Enclosure Rear View2076-212/224
Control Enclosure Rear View2076-112/124/312/324
Storwize V7000 Components
The power cooling module or PCM for the control enclosure includes
batteries to protect the cache in the node canisters. Notice the units are identical except the unit on the right
is installed upside down.
Top node canister.
The power supply unit or PSU for the control enclosure includes
batteries to protect the cache in the node canisters. Notice the units are identical except the unit on the right
is installed upside down.
The power cooling module or PCM for the expansion enclosure does not include batteries and thus are not interchangeable with control enclosure PCMs. Notice the units
are identical except the unit on the right is installed upside down.
Bottom node canister. Notice the unit is
identical to the top canister but installed
upside down.
Top expansion canister.Bottom expansion
canister. Notice the unit is identical to the
top canister but installed upside down.
The power supply unit or PSU for the expansion enclosure does not include batteries and thus are not
interchangeable with control enclosure PSUs. Notice the units
are identical except the unit on the right is installed upside down.
IBM Systems & Technology Group
© 2012 IBM Corporation18 Storwize Family
Expansion Enclosure Rear View2076-212/224
Control Enclosure Rear View2076-112/124/312/324
Storwize V7000 Components
Two 6Gbps SAS ports are available per
expansion canister for connection to other
enclosures.
Four 8Gbps fibre channel ports are available per node
canister.
Four 8Gbps fibre channel ports are available per node
canister.
Two gigE ports and two USB ports are available per node
canister.
Two gigE ports and two USB ports are available per node
canister.
Two 6Gbps SAS chains for enclosure
expansion are available per node
canister.
Expansion slot for optionally providing two 10gigE ports for iSCSI host access.
Optional CNA card providing two 10gigE ports for FCoE and
iSCSI capability.
Two 24Gbps SAS chains for expansion enclosure attachment are available per node
canister.
Two 6Gbps SAS ports are available per
expansion canister for connection to other
enclosures.
Two 6Gbps SAS ports are available per
expansion canister for connection to other
enclosures.
Two 24Gbps SAS ports are available per expansion canister for
connection to other enclosures.
IBM Systems & Technology Group
© 2012 IBM Corporation19 Storwize Family
Node Canister Details Intel Jasper Forest quad core 64-bit CPU
8GB Cache using 2 x 4GB DIMM’s
Four 2/4/8 Gbps Fibre Channel ports
– Usage optional for external storage, replication and/or for server attachment
Two USB 2.0 ports
Two 10/100/1000 Mbps Ethernet ports
– Port 1 usage required for management and/or iSCSI
– Port 2 usage optional for management and/or iSCSI
Optionally two 10gigE iSCSI ports
Two 10 Gbps Ethernet ports (Mod 312/324)
– Adapter is a FCoE card
Two 6 Gbps SAS ports
‒ Usage optional for expansion enclosures
IBM Systems & Technology Group
© 2012 IBM Corporation20 Storwize Family
SAS Ports and Cables
SAS cable is comprised of four individual wire pairs providing four 6Gbps links or lanes per cable
Each SAS lane/link is 6Gbps
– Drives are dual ported
– Path to drives is a single lane from each canister in an enclosure providing redundancy
4
4
1 2 3
1 32
A single SAS 2.0 wide port delivers up to 24Gb/s throughput. With a total of four SAS ports on the control enclosure the theoretical throughput capability of a Storwize V7000 is 96Gbps.
IBM Systems & Technology Group
© 2012 IBM Corporation21 Storwize Family
Control Enclosure Rear View2076-112/124/312/324
Expansion Enclosure Rear View2076-212/224
Notice that port 1 and port 2 are reversed on the bottom node canister
as this canister is installed upside down.
Notice that port 1 and port 2 are reversed on the bottom node canister
as this canister is installed upside down.
SAS Ports and Cabling On the control enclosure port 1 equates to SAS chain 1 and port 2 equates to SAS chain 2 on each of the node canisters. The arrows on the labels indicate that you cable-
out from the port to expansion enclosures in the chains.
On the control enclosure port 1 equates to SAS chain 1 and port 2 equates to SAS chain 2 on each of the node canisters. The arrows on the labels indicate that you cable-
out from the port to expansion enclosures in the chains. Notice
that port 1 and port 2 are reversed on the bottom node canister as this canister is installed upside down.On each expansion canister, port 1 is
the cable-in port from the control enclosure or another expansion
enclosure for a given chain. Notice the arrow on the label indicates this
is a cable-in port.
NOTE: On the expansion enclosures the port numbers have no
relationship to the SAS chain numbering.
On each expansion canister, port 2 is the cable-out port to the next
expansion enclosure in the chain. Notice the arrow on the label
indicates this is a cable-out port.
NOTE: On the expansion enclosures the port numbers have no
relationship to the SAS chain numbering.
IBM Systems & Technology Group
© 2012 IBM Corporation22 Storwize Family
What is the Storwize V7000 Unified Unified block and files storage system
‒ Tightly integrated management console
‒ NFS / CIFS / FTP / HTTPS / SCP in addition to block functions
Configuration
‒ Up to 9 expansion enclosures & 240 drives
‒ Supports 10 Gb and 1 Gb customer networks
‒ All supported back-end storage systems
IBM Active Cloud Engine™
– File based ILM
– File based asynchronous replication
– File based snapshots
– Quotas
V7000 Unified
V7000 Unified
IBM Systems & Technology Group
© 2012 IBM Corporation23 Storwize Family
Agenda
Introduction
Strowize V3700
Storwize V7000
Storwize Flex V7000
Advanced features
IBM Systems & Technology Group
© 2012 IBM Corporation24 Storwize Family24
Flex System Enterprise Chassis Front View
IBM Systems & Technology Group
© 2012 IBM Corporation25 Storwize Family25
FLEX Storage Node Usage – Architecture Overview
Front View
Functional View
HostingChassis
Storage ITEPlatform
24 Trays
Data FabricsMgmt
Fabrics
SysMgmt
(IMMv2)
Storage Processing
SAS Subsystem
Ports for Storage Expansion
Host Ports
(Mezz 1)
Host Ports
(Mezz 2)
Data FabricsMgmt
Fabrics
SysMgmt
(IMMv2)
Storage Processing
SAS Subsystem
Ports for Storage Expansion
Host Ports
(Mezz 1)
Host Ports
(Mezz 2)
In Chassis Enterprise StorageDouble high / double wide ITEDual hot swappable controllers for HAShared storage for multiple CPU ITEs
High performance/ high function storageMidrange class performance
FCoE & iSCSI block storage FC block storage as well
NAS file storage (post GA)
24 HDDs/SSDs – 2.5” hot swap disk traysVia dual SAS paths to both controllersAdd’l storage via Storage Disk Expansion Automated FW for hot spot data migration
Migrate content between SSDs and HDDs
IBM Director / Standalone based mgmtTight integration with chassis mgmtTight integration for storage and fabric mgmt
VM provisioning, copy svcs, mirroring, etc
IBM Systems & Technology Group
© 2012 IBM Corporation26 Storwize Family26
Flex System V7000 Node Canister The Node canister contains:
– One or two Host Interface Cards (HIC)– First HIC must always 2P 10 Gb/s Ethernet Mezz ( for FCoE and/or iSCSI)– Second HIC can be either:
– Four 2/4/8 Gb/s Fibre Channel ports– Two 10 Gb/s Ethernet Ports (FCoE and/or iSCSI)
– Two internal 10/100/1000 Mb/s Ethernet for management (no iSCSI)– One for IMM: IMM to L2 SW to CMM 1 or CMM 2– One for Storage: Storage to L2 SW to CMM 1 or CMM 2
– One external 6 Gb/s SAS ports (4 lanes). Usage optional– Two external USB Ports (not used for normal operation)– One Battery– Hardware is reported as “IT1” in the lsnode and lsservicestatus views.
IBM Systems & Technology Group
© 2012 IBM Corporation27 Storwize Family27
Virtualized Storage
ConsolidatedStorage
Tiered Storage
AutomatedDeployment
Innovative GUI
SAN
Thin provisioning
Space-efficient copies
External Virtualization
External Virtualization
Solid-State Storage
Hard Disks
Easy Tier
Efficiently use solid state disk to Increase performance up to 200% on critical apps.
Reduce costs by migrating less critical data to less expensive media.
Increase utilization of existing storage by up to 30%.
Reduce TCO up to 66% by deploying automated, virtualized storage.
Scale out storage to manage billions of files from a single, consolidated system.
Scale up storage with systems that can scale to store petabytes of structured data.
Deploy in minutes versus weeks: 3x faster deployment
Data Migration included with every system for rapid integration
IBM Storwize FLEX V7000
IBM Systems & Technology Group
© 2012 IBM Corporation28 Storwize Family
Agenda
Introduction
Strowize V3700
Storwize V7000
Storwize Flex V7000
Advanced features
IBM Systems & Technology Group
© 2012 IBM Corporation29 Storwize Family
Feature Comparison
Feature SVC V7000 V3700
Remote Copy Yes No(planed as license Feature in future)
Thin Provisioning Yes
Flashcopy Yes Limited to 64(planed to be lifted in the future)
Virtualisation Yes For migration only(only Image Mode Disks)
EasyTier Yes No(planed as license Feature in future)
Compression Yes No
SSDs Yes
Expansions n/a up to 9 perControl Enclosure up to 4
Clustering up to 8 Nodesup to 4 Control
Enclosures(8 Nodes)
1 Control Enclosure (2 Nodes, no NDVM)
IBM Systems & Technology Group
© 2012 IBM Corporation30 Storwize Family
Data Migration – Included
Thin Provisioning – Included
Volume Mirroring – Included
Easy Tier – Included
FlashCopy – Included
FCP, iSCSI & FCoE – Included
Non-disruptive Data Migration – Included
Metro and/or Global Mirror – Optional
Compression – Optional
External Virtualization – Optional
Advanced FunctionsVolume
MDiskTarget
Storwize V7000
MDiskSource
Volume
Volumecopy 1
Storwize V7000
Volumecopy 0
Hot-spots Optimized performance and throughput
AutomaticRelocation
SSDs HDDs SSDs HDDs
Up to 256
IBM Systems & Technology Group
© 2012 IBM Corporation31 Storwize Family
LAN
Volumes• Up to 2,048/8,192 Volumes per I/O group/cluster• Max. Volume size of 256TiB• Image Mode = Native Mode• Managed Mode = Virtualized Mode
Single Multipath driver(SDD, MPIO)
SAN
StorwizeV7000
Internal Storage External Storage
Internal Storage1 to 8/16 drives (HDD) to form an Array1 Array Managed Disk (MD)
External StorageMultiple Storage Subsystems
1 LUN Managed Disk (MDisk)
SSD SAS NL-SAS
Storage Pools• Up to 128 MDisks per
Storage Pool• Up to 128 storage pools per
cluster
Pool 3 Pool 4 Pool 5
iSCSI, FCP or FCoEHost Mapping
Virtualisation Concepts & Limits
Up to 4,096 MDisks Max. External MDiskSize of 2TiBOr greater(1)
Hosts• Up to 256/1024 Hosts per I/O group/cluster• Up to 512/2048 FC ports per I/O group/cluster• Up to 256/1024 iSCSI ports per I/O group/cluster
Pool 1 Pool 2 Vol6Vol3Vol1Vol2
(1) Check Storwize V7000 interoperability website to obtain the list of Disk Subsystems supported with greater than 2TB MDiskshttp://www-03.ibm.com/systems/storage/disk/storwize_v7000/interop.html
Round-robin port selection for back-end storage subsystems
Vol5Vol4Vol7
IBM Systems & Technology Group
© 2012 IBM Corporation32 Storwize Family
IBM Storwize V7000 Advanced Architecture Up to 4-way Clustering* - Capacity and Performance Growth in One Model
Control Enclosure
Control Enclosure
Expansion Enclosures
Scale Out (up to 960 drives)+ External virtualization for more capacity
Sca
le U
p(u
p t
o 2
40 d
rive
s)
• Business growth – Up to 4X capacity and up to 4X throughput scalability
• Fully upgradable without disruption from smallest to largest configurations: minimizes need to purchase hardware in advance of need
• Greater efficiency –Enables more consolidation, including external virtualized storage
• 120 / 240 HDDs
• 16 GB Cache
• 8x8 Gbps FC
• 4x10 Gbps iSCSI or FCoE
• 4x6 Gbps SAS
1 x Up to: • 240 / 480 HDDs
• 32 GB Cache
• 16x8 Gbps FC
• 8x10 Gbps iSCSI or FCoE
• 8x6 Gbps SAS
2 x Up to: 3 x Up to: • 360 / 720 HDDs
• 48 GB Cache
• 24x8 Gbps FC
• 12x10 Gbps iSCSI or FCoE
• 12x6 Gbps SAS
4 x Up to: • 480 / 960 HDDs
• 64 GB Cache
• 32x8 Gbps FC
• 16x10 Gbps iSCSI or FCoE
• 16x6 Gbps SAS
* V7000U File modules do not currently support clustering
IBM and IBM Business Partner Internal Use Only NOT to be distributed to customers or other third parties
IBM Systems & Technology Group
© 2012 IBM Corporation34 Storwize Family
IBM Storwize V7000 Real-time Compression Compression Without Compromise – It Works with Active Primary Data
Innovative, easy-to-use compression fully integrated into Storwize V7000– It uses same proven Random-Access Compression Engine
(RACE) as IBM RtC Appliances
High performance implementation can be used with active primary data– Supports workloads off-limits to other arrays
– Significantly expands candidates data for compression
– Greater compression benefits through use on more types of data
It operates immediately and is easy to manage– No need to schedule periods to run post-process compression
– Eliminates need to reserve space for uncompressed data waiting post-processing
By using V7000 virtualization, it significantly enhances the value of existing storage assets (including non-IBM)
Compression can help freeze storage growth or delay need for additional purchases. It helps reduce– Storage purchase costs
– Rack space, Power and cooling
– Software costs for additional functions
DB2 and Oracle databases Up to 80%
Virtual Servers (VMware)
Linux virtual OSes Up to 70%
Windows virtual OSes
Up to 50%
Office2003 Up to 60%
2007 or later Up to 20%
CAD/CAM Up to 70%
IBM Systems & Technology Group
© 2012 IBM Corporation35 Storwize Family
IBM Storwize V7000U Advanced FunctionalityInternal & External Virtualization
Storwize V7000 Unified virtualizes internal storage
– Enables rapid, flexible provisioning and simple configuration changes
– Enables non disruptive movement of data among tiers of storage, including Easy Tier
– Enables data placement optimization to improve performance
Storwize V7000 Unified also virtualizes external FC storage*
– Capacity from existing storage systems becomes part of Storwize V7000U system
– Single user interface to manage all storage, regardless of vendor: Designed to significantly improve productivity
– Virtualized storage inherits all Storwize V7000 Unified rich function including FlashCopy, Easy Tier, and thin provisioning
– Move data transparently between external storage and the Storwize V7000 Unified storage system
– Extends life and enhances value of existing storage assets
External Virtualization
* File access for externally attached storage does not support the CIFS protocol
IBM and IBM Business Partner Internal Use Only NOT to be distributed to customers or other third parties
IBM Systems & Technology Group
© 2012 IBM Corporation36 Storwize Family
If you are looking for
help in planning or executing changes
please contact your IBM representative!
IBM Systems & Technology Group
© 2012 IBM Corporation37 Storwize Family
IBM Systems & Technology Group
© 2012 IBM Corporation38 Storwize Family
IBM TS7600 ProtecTIER® FamilySupport for VTL, OST, FSI CIFS & NFS
Capacity and Performance
High Performance
High Capacity
Flexible Storage
Highest
Performance
Largest Capacity
High Availability
TS7650G ProtecTIER
Deduplication Gateway
TS7620 ProtecTIER
Deduplication
Appliance Express
Good Performance
Entry Capacity
Low Investment
Scalable From 6 – 35TB
Single Node
Up to 300 MB/sec
6TB, 12TB, 23TB, 35TB Useable
Single Node
Up to 1600/2000 MB/sec
1 PB useable
Active-Active Cluster
Up to 2500/3200 MB/sec
1 PB useable
IBM Systems & Technology Group
© 2012 IBM Corporation39 Storwize Family
TS7620 Capacity/Performance
Same enterprise-proven ProtecTIER technology
SM2 Backup Restore
VTL, OST, FSI 300 MB/s 300 MB/s
Single-stream throughput expectations:
VTL, OST, CIFS, NFS 40 MB/s
TS 7620 Capacity Options6TB12TB
23 TB35 TB
Enables users to easily scale capacity requirements to effectively meet capacity increases.
Combination of RAID 1 & 5 Technology