68 IBM XIV Storage System Host Attachment and Interoperability INFO: Gathering Windows Setup API (2/3)...                                  DONE INFO: Gathering Windows Setup API (3/3)...                                  DONE INFO: Gathering Hardware Registry Subtree...                                DONE INFO: Gathering xiv_devlist...                                              DONE INFO: Gathering Host Attachment Kit version...                                             DONE INFO: Gathering xiv_fc_admin -L...                                          DONE INFO: Gathering xiv_fc_admin -V...                                          DONE INFO: Gathering xiv_fc_admin -P...                                          DONE INFO: Gathering xiv_iscsi_admin -L...                                       DONE INFO: Gathering xiv_iscsi_admin -V...                                       DONE INFO: Gathering xiv_iscsi_admin -P...                                       DONE INFO: Gathering inquiry.py...                                               DONE INFO: Gathering drivers.py...                                               DONE INFO: Gathering mpio_dump.py...                                             DONE INFO: Gathering wmi_dump.py...                                              DONE INFO: Gathering xiv_mscs_admin --report...                               SKIPPED INFO: Gathering xiv_mscs_admin --report --debug ...                      SKIPPED INFO: Gathering xiv_mscs_admin --verify...                               SKIPPED INFO: Gathering xiv_mscs_admin --verify --debug ...                      SKIPPED INFO: Gathering xiv_mscs_admin --version...                              SKIPPED INFO: Gathering build-revision file...                                      DONE INFO: Gathering host_attach logs...                                         DONE INFO: Gathering xiv logs...                                                 DONE INFO: Gathering ibm products logs...                                        DONE INFO: Gathering vss provider logs...                                        DONE INFO: Closing xiv_diag archive file                                         DONE Deleting temporary directory...                                             DONE INFO: Gathering is now complete. INFO: You can now send c:\users\admini~1\appdata\local\temp\2\xiv_diag-results_2012-10-22_14-12-1.tar.gz to IBM-XIV for review. INFO: Exiting. 2.2  Attaching a Microsoft Windows 2008 R2 cluster to XIV This section addresses the attachment of Microsoft Windows 2008 R2 cluster nodes to the XIV Storage System. For more information, see the XIV Storage System Host System Attachment Guide for Windows - Installation Guide, which is available at: http://publib.boulder.ibm.com/infocenter/ibmxiv/r2/topic/com.ibm.help.xiv.doc/xiv_ pubsrelatedinfoic.html This section addresses the implementation of a two node Windows 2008 R2 Cluster by using FC connectivity. Important: The procedures and instructions that are given here are based on code that was available at the time of writing. For the latest support information and instructions, see the System Storage Interoperability Center (SSIC) at: http://www.ibm.com/systems/support/storage/config/ssic/index.jsp

Upload: juan-pablo-atehortua

Post on 02-Oct-2015

23 views

Category:

Documents


6 download

DESCRIPTION

IBM XIV Storage System Host Attachment and Interoperability

TRANSCRIPT

  • 68 IBMXIVStorageSystemHostAttachmentandInteroperability

    INFO:GatheringWindowsSetupAPI(2/3)...DONEINFO:GatheringWindowsSetupAPI(3/3)...DONEINFO:GatheringHardwareRegistrySubtree...DONEINFO:Gatheringxiv_devlist...DONEINFO:GatheringHostAttachmentKitversion...DONEINFO:Gatheringxiv_fc_admin-L...DONEINFO:Gatheringxiv_fc_admin-V...DONEINFO:Gatheringxiv_fc_admin-P...DONEINFO:Gatheringxiv_iscsi_admin-L...DONEINFO:Gatheringxiv_iscsi_admin-V...DONEINFO:Gatheringxiv_iscsi_admin-P...DONEINFO:Gatheringinquiry.py...DONEINFO:Gatheringdrivers.py...DONEINFO:Gatheringmpio_dump.py...DONEINFO:Gatheringwmi_dump.py...DONEINFO:Gatheringxiv_mscs_admin--report...SKIPPEDINFO:Gatheringxiv_mscs_admin--report--debug...SKIPPEDINFO:Gatheringxiv_mscs_admin--verify...SKIPPEDINFO:Gatheringxiv_mscs_admin--verify--debug...SKIPPEDINFO:Gatheringxiv_mscs_admin--version...SKIPPEDINFO:Gatheringbuild-revisionfile...DONEINFO:Gatheringhost_attachlogs...DONEINFO:Gatheringxivlogs...DONEINFO:Gatheringibmproductslogs...DONEINFO:Gatheringvssproviderlogs...DONEINFO:Closingxiv_diagarchivefileDONEDeletingtemporarydirectory...DONEINFO:Gatheringisnowcomplete.INFO:Youcannowsendc:\users\admini~1\appdata\local\temp\2\xiv_diag-results_2012-10-22_14-12-1.tar.gztoIBM-XIVforreview.INFO:Exiting.

    2.2AttachingaMicrosoftWindows2008R2clustertoXIV

    ThissectionaddressestheattachmentofMicrosoftWindows2008R2clusternodestothe

    XIVStorageSystem.

    Formoreinformation,seetheXIVStorageSystemHostSystemAttachmentGuidefor

    Windows-InstallationGuide,whichisavailableat:

    http://publib.boulder.ibm.com/infocenter/ibmxiv/r2/topic/com.ibm.help.xiv.doc/xiv_pubsrelatedinfoic.html

    ThissectionaddressestheimplementationofatwonodeWindows2008R2Clusterbyusing

    FCconnectivity.

    Important:Theproceduresandinstructionsthataregivenherearebasedoncodethat

    wasavailableatthetimeofwriting.Forthelatestsupportinformationandinstructions,see

    theSystemStorageInteroperabilityCenter(SSIC)at:

    http://www.ibm.com/systems/support/storage/config/ssic/index.jsp

  • Chapter2.XIVandWindowshostconnectivity 69

    2.2.1Prerequisites

    TosuccessfullyattachaWindowsclusternodetoXIVandaccessstorage,anumberof

    prerequisitesmustbemet.Thisisagenericlist.Yourenvironmentmighthaveextra

    requirements.

    CompletetheFCcabling.

    ConfiguretheSANzoning.

    TwonetworkadaptersandaminimumoffiveIPaddresses.

    InstallWindows2008R2SP1orlater.

    Installanyotherupdates,ifrequired.

    InstallhotfixKB2468345ifServicePack1isused.

    InstalltheHostAttachmentKittoenabletheMicrosoftMultipathI/OFramework.

    Ensurethatallnodesarepartofthesamedomain.

    CreatevolumestobeassignedtotheXIVHost/Clustergroup,nottothenodes.

    SupportedversionsofWindowsClusterServerAtthetimeofwriting,thefollowingversionsofWindowsClusterServeraresupported:

    WindowsServer2008R2(x64)

    WindowsServer2008(x32andx64)

    SupportedconfigurationsofWindowsClusterServerWindowsClusterServerwastestedinthefollowingconfigurations:

    Uptoeightnodes:Windows2008(x32andx64)

    Upto10nodes:Windows2008R2(x64)

    Ifotherconfigurationsarerequired,youneedaStorageCustomerOpportunityREquest

    (SCORE),whichreplacestheolderrequestforpricequotation(RPQ)process.IBMthentests

    yourconfigurationtodeterminewhetheritcanbecertifiedandsupported.ContactyourIBM

    representativeformoreinformation.

    SupportedFCHBAsSupportedFCHBAsareavailablefromBrocade,Emulex,IBM,andQLogic.Moreinformation

    aboutdriverversionsisavailablefromtheSSICat:

    http://www.ibm.com/systems/support/storage/config/ssic/index.jsp

    UnlessotherwisenotedinSSIC,useanysupporteddriverandfirmwarebytheHBAvendors.

    Thelatestversionsarealwayspreferred.

    Multi-pathsupportMicrosoftprovidesamulti-pathframeworkanddevelopmentkitthatiscalledtheMPIO.The

    driverdevelopmentkitallowsstoragevendorstocreateDSMsforMPIO.YoucanuseDSMs

    tobuildinteroperablemulti-pathsolutionsthatintegratetightlywithMicrosoftWindows.

    MPIOallowsthehostHBAstoestablishmultiplesessionswiththesametargetLUN,but

    presentthemtoWindowsasasingleLUN.TheWindowsMPIOdriversenableatrue

    active/activepathpolicythatallowsI/Oovermultiplepathssimultaneously.

    FurtherinformationaboutMicrosoftMPIOsupportisavailableat:

    http://download.microsoft.com/download/3/0/4/304083f1-11e7-44d9-92b9-2f3cdbf01048/mpio.doc

  • 70 IBMXIVStorageSystemHostAttachmentandInteroperability

    2.2.2InstallingClusterServices

    ThisscenariocoversatwonodeWindows2008R2Cluster.Theproceduresassumethatyou

    arefamiliarwithWindows2008Cluster.Therefore,theyfocusonspecificrequirementsfor

    attachingtoXIV.

    FormoreinformationaboutinstallingaWindows2008Cluster,see:

    http://technet.microsoft.com/en-us/windowsserver/bb310558.aspx

    Toinstallthecluster,completethesesteps:

    1. OntheXIVsystemmainGUI,selectHostsandClusters.Createaclusterandputboth

    nodesintotheclusterasdepictedinFigure 2-28.

    Figure2-28XIVclusterwithbothnodes

    Inthisexample,anXIVclusternamedclu_solmanwascreatedandbothnodeswere

    placedinit.

    2. MapalltheLUNstotheclusterasshowninFigure 2-29.

    Figure2-29MappedLUNslist

    AllLUNsaremappedtotheXIVcluster,butnottotheindividualnodes.

    3. Setupacluster-specificconfigurationthatincludesthefollowingcharacteristics:

    Allnodesareinthesamedomain

    Havenetworkconnectivity

    Private(heartbeat)networkconnectivity

  • Chapter2.XIVandWindowshostconnectivity 71

    Node2mustnotdoanyDiskI/O

    Runtheclusterconfigurationcheck

    4. OnNode1,scanfornewdisks.Then,initialize,partition,andformatthemwithNTFS.The

    followingrequirementsareforsharedclusterdisks:

    Thesedisksmustbebasicdisks.

    ForWindows2008,youmustdecidewhethertheyareMasterBootRecord(MBR)

    disksorGUIDPartitionTable(GPT)disks.

    Figure 2-30showswhatthisconfigurationlookslikeonnode1.

    Figure2-30Initialized,partitioned,andformatteddisks

  • 72 IBMXIVStorageSystemHostAttachmentandInteroperability

    5. Ensurethatonlyonenodeaccessestheshareddisksuntiltheclusterserviceisinstalled

    onallnodes.ThisrestrictionmustbedonebeforeyoucontinuetotheClusterwizard

    (Figure 2-31).YounolongermustturnoffallnodesasyoudidwithWindows2003.You

    canbringallnodesintotheclusterinasinglestep.However,nooneisallowedtoworkon

    theothernodes.

    Figure2-31CreateClusterWizardwelcomewindow

    6. SelectallnodesthatbelongtotheclusterasshowninFigure 2-32.

    Figure2-32Selectingyournodes

  • Chapter2.XIVandWindowshostconnectivity 73

    7. AftertheCreateClusterwizardcompletes,asummarypanelshowsyouthatthecluster

    wascreatedsuccessfully(Figure 2-33).Keepthisreportfordocumentationpurposes.

    Figure2-33FailoverClusterValidationReportwindow

    8. Checkaccesstoatleastoneoftheshareddrivesbycreatingadocument.Forexample,

    createatextfileononeofthem,andthenturnoffnode1.

    9. ChecktheaccessfromNode2totheshareddisksandpowernode1onagain.

  • 74 IBMXIVStorageSystemHostAttachmentandInteroperability

    10.MakesurethatyouhavethecorrectclusterwitnessmodelasillustratedinFigure 2-34.

    Theoldclustermodelhadaquorumasasinglepointoffailure.

    Figure2-34ConfigureClusterQuorumWizardwindow

    Inthisexample,theclusterwitnessmodelischanged,whichassumesthatthewitness

    shareisinathirddatacenter(seeFigure 2-35).

    Figure2-35Selectingthewitnessmodel