ies lm-80-08 - edison opto corporation edison opto corporation
TRANSCRIPT
1/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
Report Number Q130401
Test Sample 2PHM30WW38P13001
Rating DC 720mA 30W
Normal CCT 3,000 K
Test Date1. 55oC,70oC,85oC (Apr. 11, 2013 to Jan. 13, 2014)2. 105oC (Oct. 31, 2013 to Mar. 17, 2014)
Test Address9F, NO.800, Chung-Cheng Rd., Chung-Ho Dist., New Taipei City 235, Taiwan
Test StandardIES LM-80-08 Approved Method : Measuring Lumen Maintenance of Led Lighting Sources
Temp. Measure point See page 3
Description of test equipment
See page 3
Test Engineer Amos Huang
Review By Kenny Yen
Notes:1. The test center executes the test operations with prudent manners. All the test results are detail stated in the report. All test service meet under the regulations of ISO/IEC 17025.2. The report is only responsible to the assigned test. It shall not be any of the bases of Compliance judgments.3. There are 13 pages in the test report (include the cover page). It is invalid when being used separately.4. The test report is forbidden to reproduce in separate pages. The complete report copy is unrestricted.5. The recorded contents in this report shall not be used as advertising, publications or merchandising purposes without written permissions by the test center.6. Lumen maintenance(lm) uncertainty=6.2%; Chromaticity(x,y) uncertainty=0.0002.
IES LM-80-08 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCE
2/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
According to section 3 item 7 and section 4 item 5 of ENERGY STAR® Program Guidance Regarding LED Package, LED Array and LED Module Lumen Maintenance Performance Data Supporting Qualification of Lighting Products, the test report also applies to the following products:
Part Number Normal CCT Watt W/mm^2
2PHM30WW38P13001 3000K 30 0.074
2PHM30NW38P13001 4000K 30 0.074
2PHM30CW38P13001 5700K 30 0.074
2PHM16WW38P13001 3000K 16 0.037
2PHM16NW38P13001 4000K 16 0.037
2PHM16CW38P13001 5700K 16 0.037
2PHM30WW27P13001 3000K 30 0.074
2PHM30NW27P13001 4000K 30 0.074
2PHM30CW27P13001 5700K 30 0.074
2PHM16WW27P13001 3000K 16 0.037
2PHM16NW27P13001 4000K 16 0.037
2PHM16CW27P13001 5700K 16 0.037
2PHM24WW27P13001 3000K 24 0.061
2PHM24NW27P13001 4000K 24 0.061
2PHM24CW27P13001 5700K 24 0.061
3/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
Equipment Model No. / Serial No. Cal. Laboratory Report No. Effective Date
Integrating sphere ISP25045392012
Deutscher Akkreditierungs RatDAT-PL-293/09-00
CAL-141-12-058 02.08.2014
DC power source KEITHLEY 24004000282
Tai YiTAF-1625 T3306141201 17.06.2014
Temperature controlled test
VEKTREX/ SpikeSafe 2001080030009
Tai YiTAF-1625
T3305240801
27.05.2014
VEKTREX/ ITCS 428 T3305240701
VEKTREX/ ITCS 429 T3305240702
VEKTREX/ ITCS 430 T3305240703
Ts Measurement Point2. Case and ambient temperatureThe case temperature Ts is the temperature on the substrate; the ambient temperature TA is the temperature of the air at a distance of 50 mm above substrate.
3. Description of test equipment
1. Test Summary
Case temperature (Ts) 53oC ≤ Ts 68oC ≤ Ts 83oC ≤ Ts 103oC ≤ Ts
Ambient conditions (TA)50oC ≤ TA
R.H. < 65 % Minimized airflow
65oC ≤ TA R.H. < 65 %
Minimized airflow
80oC ≤ TA R.H. < 65 %
Minimized airflow
100oC ≤ TA R.H. < 65 %
Minimized airflow
Sample Size 10 10 10 10
Drive current of the LED 720mA 720mA 720mA 720mA
Initial flux (lm) / VF(V) 2641.9 / 36.9 2637.2 / 36.9 2629.1 / 36.9 2649.7 / 37.5
Lumen maintenance at 7000 hrs 98.33% Page 5
96.36% Page 7
96.01% Page 9
98.17% Page 11
LED failure 0 0 0 0
Monitoring interval (hrs) 0,1000,2000,3000,4000,5000,6000,7000 0,1000,2000,3000
Chromaticity shift Page 6 Page 8 Page 10 Page 12
Ts
4/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
Package Dimensions and Polarity
16W/ 30W Emitter Dimensions
Notes : 1. Unit : mm2. Tolerance : ± 0.2 mm3. Drawings are not to scale4. TP : Thermal measurement point
16W EdiPower® II HM Series Circuit Layout
16W/ 30W Emitter Circuit Layout
(1)
(2)
(3)
30W EdiPower® II HM Series Circuit Layout
(1)
(2)
(6)
1.6
17
1
R2.00
19
19
7.1
9.5
5.59.5R2.00
9.5
7.1
1.6
3.2 5.5 9.5
3.2
1.6
5/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2663.3 1.000 0.998 1.000 0.997 1.001 0.995 0.990 0.986
2 2613.6 1.000 0.997 0.998 0.995 1.000 0.994 0.991 0.985
3 2643.8 1.000 0.996 1.001 1.000 0.993 0.988 0.985 0.979
4 2670.1 1.000 0.996 0.997 0.995 0.999 0.994 0.990 0.987
5 2657.4 1.000 0.996 0.998 0.996 0.989 0.984 0.981 0.976
6 2621.0 1.000 0.996 0.992 0.992 0.992 0.985 0.985 0.978
7 2627.7 1.000 0.994 0.992 0.990 0.989 0.985 0.983 0.978
8 2677.4 1.000 0.996 0.990 0.990 0.994 0.987 0.986 0.982
9 2651.3 1.000 0.997 0.998 0.994 0.989 0.983 0.983 0.977
10 2629.7 1.000 0.997 0.993 0.993 0.991 0.984 0.982 0.977
AVG 2645.5 1.000 0.996 0.996 0.994 0.994 0.988 0.985 0.980
MIN 2613.6 1.000 0.994 0.990 0.990 0.989 0.983 0.981 0.976
MAX 2677.4 1.000 0.998 1.001 1.000 1.001 0.995 0.991 0.987
4. Test Results 4.1 Lumen and Color Maintenance data (55 oC)
■ Lumen Maintenance data (55 oC)
6/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
∆ u’v’
No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2752.4 0 0.0001 0.0002 0.0006 0.0004 0.0003 0.0002 0.0004
2 2755.0 0 0.0001 0.0002 0.0004 0.0003 0.0002 0.0002 0.0003
3 2740.8 0 0.0001 0.0003 0.0004 0.0005 0.0004 0.0002 0.0001
4 2753.2 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0002 0.0003
5 2742.1 0 0.0001 0.0002 0.0004 0.0003 0.0002 0.0001 0.0002
6 2750.9 0 0.0001 0.0003 0.0006 0.0002 0.0001 0.0003 0.0004
7 2753.5 0 0.0002 0.0002 0.0005 0.0002 0.0002 0.0003 0.0004
8 2755.3 0 0.0001 0.0003 0.0006 0.0002 0.0001 0.0003 0.0004
9 2744.5 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0001 0.0002
10 2753.4 0 0.0001 0.0003 0.0006 0.0003 0.0002 0.0004 0.0005
AVG 2750.1 0 0.0001 0.0002 0.0005 0.0003 0.0002 0.0002 0.0003
MIN 2740.8 0 0.0001 0.0002 0.0004 0.0002 0.0001 0.0001 0.0001
MAX 2755.3 0 0.0002 0.0003 0.0006 0.0005 0.0004 0.0004 0.0005
■ Color Maintenance data (55 oC)
Test Condition 1 - 55⁰C Case Temp
Sample size 10
Number of failures 0
DUT drive current used in the test (mA) 720
Test duration (hours) 7,000
Test duration used for projection (hour to hour) 2,000 - 7,000
Tested case temperature (⁰C) 55
α 3.141E-06
B 1.004
Calculated L70(7k) (hours) 115,000
Reported L70(7k) (hours) >39000
7/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
4.2 Lumen and Color Maintenance data (70 oC)
■ Lumen Maintenance data (70 oC)
No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2658.6 1.000 0.997 1.006 1.000 0.989 0.984 0.962 0.950
2 2608.7 1.000 0.996 1.000 0.998 1.001 0.994 0.981 0.975
3 2634.3 1.000 0.998 0.998 0.997 0.993 0.986 0.976 0.968
4 2628.8 1.000 0.996 0.993 0.985 0.968 0.963 0.941 0.935
5 2654.0 1.000 0.996 0.991 0.991 0.991 0.987 0.974 0.970
6 2673.5 1.000 0.995 0.999 0.993 0.987 0.981 0.969 0.965
7 2620.2 1.000 0.997 0.995 0.993 0.992 0.989 0.977 0.970
8 2623.4 1.000 0.996 0.993 0.989 0.979 0.977 0.963 0.958
9 2649.3 1.000 0.997 0.996 0.998 0.997 0.997 0.982 0.976
10 2620.9 1.000 0.996 0.995 0.996 0.998 0.991 0.975 0.970
AVG 2637.2 1.000 0.996 0.997 0.994 0.989 0.985 0.970 0.964
MIN 2608.7 1.000 0.995 0.991 0.985 0.968 0.963 0.941 0.935
MAX 2673.5 1.000 0.998 1.006 1.000 1.001 0.997 0.982 0.976
8/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
∆ u’v’
■ Color Maintenance data (70 oC)
Test Condition 2 - 70⁰C Case Temp
Sample size 10
Number of failures 0
DUT drive current used in the test (mA) 720
Test duration (hours) 7,000
Test duration used for projection (hour to hour) 2,000 - 7,000
Tested case temperature (⁰C) 70
α 7.062E-06
B 1.015
Calculated L70(7k) (hours) 53,000
Reported L70(7k) (hours) >39000
No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2743.4 0 0.0001 0.0007 0.0005 0.0009 0.0008 0.0008 0.0016
2 2754.2 0 0.0001 0.0006 0.0005 0.0005 0.0002 0.0004 0.0004
3 2752.0 0 0.0001 0.0006 0.0005 0.0005 0.0003 0.0003 0.0003
4 2756.6 0 0.0001 0.0005 0.0006 0.0012 0.0011 0.0002 0.0002
5 2744.0 0 0.0001 0.0006 0.0005 0.0006 0.0005 0.0002 0.0002
6 2748.8 0 0.0001 0.0006 0.0006 0.0009 0.0009 0.0006 0.0005
7 2754.2 0 0.0001 0.0005 0.0005 0.0006 0.0004 0.0003 0.0002
8 2750.3 0 0.0000 0.0005 0.0006 0.0009 0.0008 0.0006 0.0004
9 2741.8 0 0.0001 0.0008 0.0006 0.0006 0.0004 0.0003 0.0002
10 2749.4 0 0.0001 0.0005 0.0004 0.0005 0.0003 0.0002 0.0001
AVG 2749.5 0 0.0001 0.0006 0.0005 0.0007 0.0006 0.0004 0.0004
MIN 2741.8 0 0.0000 0.0005 0.0004 0.0005 0.0002 0.0002 0.0001
MAX 2756.6 0 0.0001 0.0008 0.0006 0.0012 0.0011 0.0008 0.0016
9/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
4.3 Lumen and Color Maintenance data (85 oC)
■ Lumen Maintenance data (85 oC)
No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2611.0 1.000 0.995 0.997 0.997 0.984 0.977 0.970 0.957
2 2686.8 1.000 0.993 0.996 0.996 0.990 0.985 0.979 0.963
3 2626.0 1.000 0.995 0.997 0.997 0.992 0.984 0.977 0.964
4 2653.2 1.000 0.993 0.993 0.995 0.988 0.980 0.973 0.958
5 2683.2 1.000 0.994 0.999 0.999 0.996 0.988 0.983 0.970
6 2599.8 1.000 0.992 0.995 0.998 0.996 0.990 0.984 0.970
7 2602.9 1.000 0.994 0.997 0.997 0.987 0.984 0.976 0.961
8 2611.9 1.000 0.993 0.991 0.984 0.967 0.963 0.955 0.941
9 2600.8 1.000 0.995 0.996 0.994 0.983 0.976 0.969 0.955
10 2615.9 1.000 0.994 0.989 0.991 0.991 0.986 0.977 0.963
AVG 2629.1 1.000 0.994 0.995 0.995 0.987 0.981 0.974 0.960
MIN 2599.8 1.000 0.992 0.989 0.984 0.967 0.963 0.955 0.941
MAX 2686.8 1.000 0.995 0.999 0.999 0.996 0.990 0.984 0.970
10/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
∆ u’v’
■ Color Maintenance data (85 oC)
Test Condition 3 - 85⁰C Case Temp
Sample size 10
Number of failures 0
DUT drive current used in the test (mA) 720
Test duration (hours) 7,000
Test duration used for projection (hour to hour) 2,000 - 7,000
Tested case temperature (⁰C) 85
α 7.077E-06
B 1.014
Calculated L70(7k) (hours) 52,000
Reported L70(7k) (hours) >39000
No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2756.6 0 0.0001 0.0005 0.0004 0.0007 0.0005 0.0004 0.0003
2 2749.6 0 0.0001 0.0004 0.0003 0.0004 0.0002 0.0003 0.0003
3 2747.4 0 0.0001 0.0004 0.0003 0.0003 0.0003 0.0004 0.0005
4 2740.2 0 0.0001 0.0007 0.0005 0.0005 0.0003 0.0001 0.0002
5 2755.2 0 0.0001 0.0004 0.0003 0.0003 0.0002 0.0004 0.0004
6 2750.4 0 0.0003 0.0005 0.0004 0.0005 0.0003 0.0005 0.0006
7 2756.8 0 0.0002 0.0005 0.0004 0.0005 0.0002 0.0003 0.0003
8 2756.9 0 0.0002 0.0005 0.0006 0.0012 0.0009 0.0007 0.0006
9 2753.8 0 0.0001 0.0005 0.0004 0.0005 0.0003 0.0002 0.0003
10 2746.4 0 0.0001 0.0006 0.0005 0.0004 0.0003 0.0004 0.0005
AVG 2751.3 0 0.0001 0.0005 0.0004 0.0005 0.0004 0.0004 0.0004
MIN 2740.2 0 0.0001 0.0004 0.0003 0.0003 0.0002 0.0001 0.0002
MAX 2756.9 0 0.0003 0.0007 0.0006 0.0012 0.0009 0.0007 0.0006
11/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
4.3 Lumen and Color Maintenance data (105 oC)
■ Lumen Maintenance data (105 oC)
No. lm(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2657.8 1.000 0.995 0.987 0.982 - - - -
2 2610.7 1.000 0.992 0.986 0.979 - - - -3 2669.7 1.000 0.995 0.989 0.982 - - - -4 2672.4 1.000 0.993 0.989 0.981 - - - -5 2673.9 1.000 0.994 0.985 0.981 - - - -6 2637.1 1.000 0.993 0.988 0.983 - - - -7 2645.8 1.000 0.994 0.989 0.984 - - - -8 2631.7 1.000 0.994 0.987 0.982 - - - -9 2637.1 1.000 0.994 0.985 0.981 - - - -
10 2661.1 1.000 0.993 0.988 0.982 - - - -AVG 2649.7 1.000 0.994 0.987 0.982 - - - -MIN 2610.7 1.000 0.992 0.985 0.979 - - - -MAX 2673.9 1.000 0.995 0.989 0.984 - - - -
12/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
∆ u’v’
■ Color Maintenance data (105 oC)
Test Condition 4 - 105⁰C Case Temp
Sample size 10
Number of failures 0
DUT drive current used in the test (mA) 720
Test duration (hours) 3,000
Test duration used for projection (hour to hour) 1,000 - 3,000
Tested case temperature (⁰C) 105
α -
B -
Calculated L70(7k) (hours) -
Reported L70(7k) (hours) >39000
No. CCT(Initial) 0h 1000h 2000h 3000h 4000h 5000h 6000h 7000h
1 2716.5 0 0.0001 0.0004 0.0005 - - - -
2 2750.0 0 0.0003 0.0004 0.0006 - - - -
3 2761.5 0 0.0002 0.0003 0.0006 - - - -
4 2733.2 0 0.0003 0.0004 0.0006 - - - -
5 2727.7 0 0.0002 0.0005 0.0005 - - - -
6 2766.7 0 0.0003 0.0004 0.0005 - - - -
7 2728.0 0 0.0002 0.0004 0.0004 - - - -
8 2726.0 0 0.0002 0.0004 0.0005 - - - -
9 2723.1 0 0.0002 0.0005 0.0005 - - - -
10 2726.6 0 0.0002 0.0004 0.0005 - - - -
AVG 2735.9 0 0.0002 0.0004 0.0005 - - - -
MIN 2716.5 0 0.0001 0.0003 0.0004 - - - -
MAX 2766.7 0 0.0003 0.0005 0.0006 - - - -
13/13www.edison-opto.comCopyright © 2014 Edison Opto Corporation. All right reserved. The information in this document is subject to change without notice.
version : 2.1
Edison Opto Corporation4F,NO.800, Chung-Cheng Rd., Chung-Ho Dist.,New Taipei City 235,TaiwanTel:+886 28227 6996Fax:+886 28227 6997
OPTO Laboratory Test Report
Report NO. Q130401
About Edison Opto
Edison Opto is a leading manufacturer of high power LED and a solution provider experienced in LDMS. LDMS is an integrated program derived from the four essential technologies in LED lighting applications- Thermal Management, Electrical Scheme, Mechanical Refinement, Optical Optimization, to provide customer with various LED components and modules. More Information about the company and our products can be found at www.edison-opto.com
Copyright©2014 Edison Opto. All rights reserved. No part of publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photo copy, recording or any other information storage and retrieval system, without prior permission in writing from the publisher. The information in this publication are subject to change without notice.
www.edison-opto.com
For general assistance please contact:[email protected]
For technical assistance please contact:[email protected]
5. EPA Recognized Certification Laboratory Information
EPA Recognized Certification Bodies (CBs) and Laboratories List ResultsNotes:1. Only accredited laboratories are listed on this page. Laboratories that are EPA-recognized through enrolling in a Certification Body's WMTL or SMTL program are not listed here.2. EPA encourages manufacturers to contact laboratories directly to ensure they have the capability and availability to test the particular products for which certification is sought, as some product types may require special testing equipment or capabilities. Manufacturers must also confirm with an EPA-recognized certification body (CB) that the laboratory is acceptable under the CB's program for that product type.3. Windows, Doors, and Skylights partners are advised to contact the National Fenestration Rating Council(www. nfrc.org ) for a complete list of EPA-recognized laboratories for these products.4. Lighting (CFLs, ILLs, Luminaires, and Decorative Light Strings) Labs and CBs are listed separately.5. Please note, EPA recognizes the Association of Home Appliance Manufacturers (AHAM) only for administering verification testing.
Organization ID
Organization Name
Type of Recognized
Body
If Lab is it 1st Party? Programs Organization
Address City State Country
1114690
Edison Opto Corporation - OPTO Testing
Laboratory
Accredited Laboratory Y Luminaires
4F, NO.800, Chung-Cheng Rd., Chung-Ho
Dist.,
New Taipei City
- TW