ignite your routine testing methodsper-form.hu/wp-content/uploads/2015/08/...dmc.pdf · ignite your...

29
Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

Upload: others

Post on 12-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

Ignite your Routine Testing Methods

Daniel McMillan, SCIEXBudapest, 27th April 2016

Page 2: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

3 © 2015 AB Sciex

AB SCIEX TripleTOF™ 4600 SystemIon Path Innovations – The Best of Both Worlds

• Qualitative analysis power of a high resolution accurate mass analyzer

• Quantitative speed and sensitivity of a triple quadrupole instrument

Page 3: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

18 © 2015 AB Sciex

What’s New?

SCIEX X500R QTOF System powered by SCIEX OS Software

SCIEX ExionLC™ AC system SCIEX OS software

SCIEX X500R QTOF system

Page 4: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

20 © 2015 AB Sciex

Introducing the SCIEX X500R QTOF System

Design Improvements and Details

Minimized footprintThe benchtop stature (110 x 57 x 112 cm)* occupies less lab space than any other HRMS system on the market.

Integrated calibrationMaintains mass calibration through long runs without effect on sample flow.

Engineered for simplicityOptimal performance delivered through adjustment of only 2 voltage variables.

Service accessibilityEasy QJet access for fast and efficient

maintenance and single three stage split flow pump for increased system uptime.

TwinSprayAn independent calibrant delivery path for reliable

auto-calibration.

Page 5: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

21 © 2015 AB Sciex

Introducing the SCIEX X500R QTOF System

Design Improvements and Details

N-optic design4 mm orifice leading into TOF accelerator

tube delivers resolution without compromise in

sensitivity.

Heated TOF pathSix heater drones

throughout the TOF path to maintain robustness

and mass accuracy.

Page 6: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

22 © 2015 AB Sciex

Introducing the SCIEX X500R QTOF System

Design Improvements and Details

Legendary Turbo V source with optional IonDrive and Curtain Gas interface

Renowned ionization performance and ruggedness now delivered with a high

resolution accurate mass analyzer.

Page 7: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

23 © 2015 AB Sciex

Perfect Balance to Elevate Your Lab’s Performance

• The first robust, high performance high resolution MS/MS system designed for routine use.‒ Sensitivity to easily detect maximum residue levels‒ Resolving power to remove interference from complex

food matrices‒ Linearity to quantify over up to 4 orders of magnitude‒ Mass accuracy to identify compounds following regulatory

guidelines‒ Confident identification based MS/MS (IDA and

SWATH™ MS/MSALL, ion ratios and MS/MS spectra)‒ Industry leading robustness of Turbo V™ source and

Curtain Gas™ interface

SCIEX X500R QTOF System

Page 8: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

24 © 2015 AB Sciex

The SCIEX X500R QTOF System – Performance

Sensitivity and Resolution (20 µg/kg Pesticides in Fruit, 5 µL injected)

Cyromazine@ 167.10452

Spinosyn A@ 732.46867

Trifloxystrobin@ 409.13752

Imazalil@ 297.05614

Carbendazime@ 192.07730

Page 9: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

25 © 2015 AB Sciex

The SCIEX X500R QTOF System – Performance

Linearity and Mass Accuracy (Paclobutrazol 0.1 to 10,000 ng/mL)

0.1 1,000100101 10,000(excluded)

r2 = 0.99934 orders linear dynamic range

Mass error = -0.2 to 0.91 ppm

Page 10: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

26 © 2015 AB Sciex

Information Dependent Acquisition of MS/MS (IDA)

Provides MS/MS Spectra with High Selectivity (Q1 Resolution unit)

IDA can be used with and without inclusion list for target or non-target screening

Page 11: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

27 © 2015 AB Sciex

The SCIEX X500R QTOF System – IDA

Confident Identification of Isomers using MS/MS (Prometon vs. Terbumeton)

PrometonC10H19N5O+H+

RT = 5.44 min

TerbumetonC10H19N5O+H+

RT = 5.53 min

MS: 226.1664(0.63 ppm)

MS 226.1665(0.99 ppm)

MS/MS: 98.5%

MS/MS: 95.7%

Identification based on MS/MS library searching (Q1 at unit resolution)

Page 12: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

28 © 2015 AB Sciex

MS/MSALL using SWATH ™ Acquisition

A Mode of Data Independent Acquisition Providing MS/MSALL

SWATH™: Wide Q1 Isolation Window is Stepped Across the Mass Range

Page 13: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

30 © 2015 AB Sciex

The SCIEX X500R QTOF System – SWATH™ MS/MS ALL

Confident Identification of Isomers using SWATH (Prometon vs. Terbumeton)

Prometon226/184.1193RT = 5.44 min

Terbumeton226/170.1036RT = 5.54 min

MS: 226.16641(0.77 ppm)

MS 226.16641(0.77 ppm)

Identification based on unique fragment ions and their ratios

*

*

**

**

*

**

*

*

**

*

Page 14: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

32 © 2015 AB Sciex

MRMHR

209/192.0404 and 209/166.0611

MRM 209/192 and 209/166

TOF-MSXIC of 209.0675 ± 10 ppm

Increased Selectivity using MRM HR

Feed Sample Tested Positive for NP-Semicarbazide

Page 15: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

33 © 2015 AB Sciex

S/N = 9.6 S/N = 26

Comparison of TOF MS vs. SWATH vs. MRM HR Quant

S/N = 166

Selectivity

TOF MS SWATH MRMHR

Sensitivity

Loratidine

Page 16: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

34 © 2015 AB Sciex

Perfect Balance to Elevate Your Lab’s Performance

• The first robust, high performance high resolution MS/MS system designed for routine use.‒ Sensitivity to easily detect maximum residue levels‒ Resolving power to remove interference from complex

food matrices‒ Linearity to quantify over up to 4 orders of magnitude‒ Mass accuracy to identify compounds following regulatory

guidelines‒ Confident identification based MS/MS (IDA and

SWATH™ MS/MSALL, ion ratios and MS/MS spectra)‒ Industry leading robustness of Turbo V™ source and

Curtain Gas™ interface

• Simple software workflows that deliver reliable results, it’s the solution that’s ready to meet your challenges today and for the future, from the trusted LC-MS/MS industry leader.

SCIEX X500R QTOF System Powered by SCIEX OS Software

Page 17: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

35 © 2015 AB Sciex

Introducing the SCIEX OS Software

Single Software Platform for MS Control, Data Processing and Reporting

Page 18: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

37 © 2015 AB Sciex

SCIEX OS Software – Home

Everything in a Single Software Platform

AcquisitionBuild MS and LC methodsCreate batchesRun samples

ProcessingSimultaneous Identification

and quantitation

ManagementAdjust hardware, software, and user settings

Page 19: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

43 © 2015 AB Sciex

Targeted Data Processing Workflow

XIC generation for each target

Identification

RT � Mass �

Isotopes �

MS/MS search �

Quantitation

Above reporting level

Page 20: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

44 © 2015 AB Sciex

Identification and Quantitation in SCIEX OS Softwar e

1. Define Retention Time and Accurate Mass for Each Target Analyte

Page 21: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

45 © 2015 AB Sciex

Identification and Quantitation in SCIEX OS Softwar e

2. Define Identification Criteria and Confidence Settings

Page 22: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

46 © 2015 AB Sciex

Identification and Quantitation in SCIEX OS Softwar e

3. Review Qualitative and Quantitative Results

Flagging when above MRL and traffic lights for confidence

Review of peak integration, spectra and calibration line

Page 23: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

53 © 2015 AB Sciex

SCIEX OS Software – Unknown Identification

Software Improvements and Details

Automatic sample-control comparison

ChemSpider searchingSorting by number of references and automatic structure elucidation to identify unknowns

Non-Target peak finding

Automatic MS/MS library searching and formula findi ng

Page 24: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

54 © 2015 AB Sciex

Non-Targeted Data Processing Workflow

Sample-control comparison

MS/MS search �

Identification

Formula finding�

Mass and RT

Page 25: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

55 © 2015 AB Sciex

Unknown Identification in SCIEX OS Software

1. Define Non-Target Peak Finding and Identification Parameters

Page 26: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

56 © 2015 AB Sciex

Unknown Identification in SCIEX OS Software

2. Automatic Sample-Control Comparison and Compound Identification

Automatic formula finding and MS/MS library searching

Page 27: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

57 © 2015 AB Sciex

Unknown Identification in SCIEX OS Software

3. ChemSpider Searching and Structure Elucidation

ChemSpider searching of found formulaeAutomatic structure elucidation using HR-MS/MS spectra

Page 28: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

59 © 2015 AB Sciex

• Hardware and Software‒ New SCIEX ExionLC™ systems

‒ Fully controlled by SCIEX OS software

‒ New SCIEX Triple Quad™ and QTRAP® 6500+ systems‒ Improved IonDrive™ detection system‒ Elevated SelexION® technology

‒ New SCIEX X500R QTOF System‒ N-optic design‒ Heated TOF path‒ Minimized footprint, engineered for simplicity and

service accessibility‒ New SCIEX OS Software

‒ New user interface‒ Simultaneous identification and quantitation ‒ Automatic unknown identification

• Application data

Summary

Page 29: Ignite your Routine Testing Methodsper-form.hu/wp-content/uploads/2015/08/...DMc.pdf · Ignite your Routine Testing Methods Daniel McMillan, SCIEX Budapest, 27th April 2016

62 © 2015 AB Sciex

For Research Use Only. Not for use in diagnostic procedures.

The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners.

© 2015 AB Sciex.

Trademarks/Licensing