im610-a sp-175plus - lincoln electric · sp-175 plus for engine powered equipment. 1.a. turn the...

49
SP-175 Plus OPERATOR’S MANUAL IM610-A May, 2002 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful. For use with machine Code Numbers 10542,10743 • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • Date of Purchase: Serial Number: Code Number: Model: Where Purchased: Copyright © 2002 Lincoln Global Inc. This manual covers equipment which is no longer in production by The Lincoln Electric Co. Specifications and availability of optional features may have changed.

Upload: dothu

Post on 12-Nov-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

SP-175 Plus

OPERATOR’S MANUAL

IM610-AMay, 2002

Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However, youroverall safety can be increased byproper installation ... and thought-ful operation on your part. DONOT INSTALL, OPERATE ORREPAIR THIS EQUIPMENTWITHOUT READING THISMANUAL AND THE SAFETYPRECAUTIONS CONTAINEDTHROUGHOUT. And, mostimportantly, think before you actand be careful.

For use with machine Code Numbers 10542,10743

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

Date of Purchase:Serial Number:Code Number:Model:Where Purchased:

Copyright © 2002 Lincoln Global Inc.

This manual covers equipment which is no longer in production by The Lincoln Electric Co. Speci�cations and availability of optional features may have changed.

SP-175 PLUS

FOR ENGINEpowered equipment.

1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

____________________________________________________1.b. Operate engines in open, well-ventilated

areas or vent the engine exhaust fumesoutdoors.

____________________________________________________1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.Stop the engine and allow it to cool beforerefueling to prevent spilled fuel from vaporiz-ing on contact with hot engine parts andigniting. Do not spill fuel when filling tank. Iffuel is spilled, wipe it up and do not startengine until fumes have been eliminated.

____________________________________________________1.d. Keep all equipment safety guards, covers and devices in

position and in good repair.Keep hands, hair, clothing andtools away from V-belts, gears, fans and all other movingparts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safetyguards to perform required maintenance. Removeguards only when necessary and replace them when themaintenance requiring their removal is complete.Always use the greatest care when working near movingparts.

___________________________________________________1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor oridler by pushing on the throttle control rodswhile the engine is running.

___________________________________________________1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenancework, disconnect the spark plug wires, distributor cap ormagneto wire as appropriate.

iSAFETYi

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that youpurchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is availablefrom the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES AREPERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ʻ95

ELECTRIC ANDMAGNETIC FIELDSmay be dangerous

2.a. Electric current flowing through any conductor causeslocalized Electric and Magnetic Fields (EMF). Weldingcurrent creates EMF fields around welding cables andwelding machines

2.b. EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physicianbefore welding.

2.c. Exposure to EMF fields in welding may have other healtheffects which are now not known.

2.d. All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Securethem with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode andwork cables. If the electrode cable is on your rightside, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close aspossible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove theradiator pressure cap when the engine ishot.

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituentsare known to the State of California to cause can-cer, birth defects, and other reproductive harm.

The engine exhaust from this product containschemicals known to the State of California to causecancer, birth defects, or other reproductive harm.

The Above For Diesel Engines The Above For Gasoline Engines

SP-175 PLUS

iiSAFETYii

ARC RAYS can burn.4.a. Use a shield with the proper filter and cover

plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistantmaterial to protect your skin and that of your helpers fromthe arc rays.

4.c. Protect other nearby personnel with suitable, non-flammablescreening and/or warn them not to watch the arc nor exposethemselves to the arc rays or to hot spatter or metal.

ELECTRIC SHOCK cankill.3.a. The electrode and work (or ground) circuits

are electrically “hot” when the welder is on.Do not touch these “hot” parts with your bareskin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation.Make certain the insulation is large enough to cover your fullarea of physical contact with work and ground.

In addition to the normal safety precautions, if weldingmust be performed under electrically hazardousconditions (in damp locations or while wearing wetclothing; on metal structures such as floors, gratings orscaffolds; when in cramped positions such as sitting,kneeling or lying, if there is a high risk of unavoidable oraccidental contact with the workpiece or ground) usethe following equipment:

• Semiautomatic DC Constant Voltage (Wire) Welder.• DC Manual (Stick) Welder.• AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode,electrode reel, welding head, nozzle or semiautomaticwelding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electricalconnection with the metal being welded. The connectionshould be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical(earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable andwelding machine in good, safe operating condition. Replacedamaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts ofelectrode holders connected to two welders because voltagebetween the two can be the total of the open circuit voltageof both welders.

3.i. When working above floor level, use a safety belt to protectyourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

FUMES AND GASEScan be dangerous.5.a. Welding may produce fumes and gases

hazardous to health. Avoid breathing thesefumes and gases.When welding, keepyour head out of the fume. Use enoughventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. Whenwelding with electrodes which require specialventilation such as stainless or hard facing (seeinstructions on container or MSDS) or on lead orcadmium plated steel and other metals or coatingswhich produce highly toxic fumes, keep exposure aslow as possible and below Threshold Limit Values (TLV)using local exhaust or mechanical ventilation. Inconfined spaces or in some circumstances, outdoors, arespirator may be required. Additional precautions arealso required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vaporscoming from degreasing, cleaning or spraying operations.The heat and rays of the arc can react with solvent vapors toform phosgene, a highly toxic gas, and other irritating prod-ucts.

5.c. Shielding gases used for arc welding can displace air andcause injury or death. Always use enough ventilation,especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturerʼs instructions for thisequipment and the consumables to be used, including thematerial safety data sheet (MSDS) and follow youremployerʼs safety practices. MSDS forms are available fromyour welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ʻ95

SP-125 PLUS

FOR ELECTRICALLYpowered equipment.

8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.

8.b. Install equipment in accordance with the U.S. NationalElectrical Code, all local codes and the manufacturerʼsrecommendations.

8.c. Ground the equipment in accordance with the U.S. NationalElectrical Code and the manufacturerʼs recommendations.

CYLINDER may explodeif damaged.7.a. Use only compressed gas cylinders

containing the correct shielding gas for theprocess used and properly operatingregulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable forthe application and maintained in good condition.

7.b. Always keep cylinders in an upright position securelychained to an undercarriage or fixed support.

7.c. Cylinders should be located:• Away from areas where they may be struck or subjected tophysical damage.

• A safe distance from arc welding or cutting operations andany other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any otherelectrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outletwhen opening the cylinder valve.

7.f. Valve protection caps should always be in place and handtight except when the cylinder is in use or connected foruse.

7.g. Read and follow the instructions on compressed gascylinders, associated equipment, and CGA publication P-l,“Precautions for Safe Handling of Compressed Gases inCylinders,” available from the Compressed Gas Association1235 Jefferson Davis Highway, Arlington, VA 22202.

iiiSAFETYiii

Mar ʻ95

WELDING SPARKS cancause fire or explosion.6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to preventthe welding sparks from starting a fire.Remember that welding sparks and hot

materials from welding can easily go through small cracksand openings to adjacent areas. Avoid welding nearhydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,special precautions should be used to prevent hazardoussituations. Refer to “Safety in Welding and Cutting” (ANSIStandard Z49.1) and the operating information for theequipment being used.

6.c. When not welding, make certain no part of the electrodecircuit is touching the work or ground. Accidental contactcan cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until theproper steps have been taken to insure that such procedureswill not cause flammable or toxic vapors from substancesinside. They can cause an explosion even though they havebeen “cleaned”. For information, purchase “RecommendedSafe Practices for the Preparation for Welding and Cutting ofContainers and Piping That Have Held HazardousSubstances”, AWS F4.1 from the American Welding Society(see address above).

6.e. Vent hollow castings or containers before heating, cutting orwelding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oilfree protective garments such as leather gloves, heavy shirt,cuffless trousers, high shoes and a cap over your hair. Wearear plugs when welding out of position or in confined places.Always wear safety glasses with side shields when in awelding area.

6.g. Connect the work cable to the work as close to the weldingarea as practical. Work cables connected to the buildingframework or other locations away from the welding areaincrease the possibility of the welding current passingthrough lifting chains, crane cables or other alternate cir-cuits. This can create fire hazards or overheat lifting chainsor cables until they fail.

6.h. Also see item 1.c.

SP-175 PLUS

ivSAFETYiv

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissent dans cemanuel aussi bien que les précautions de sûreté générales suiv-antes:

Sûreté Pour Soudage A LʼArc1. Protegez-vous contre la secousse électrique:

a. Les circuits à lʼélectrode et à la piéce sont sous tensionquand la machine à souder est en marche. Eviter toujourstout contact entre les parties sous tension et la peau nueou les vétements mouillés. Porter des gants secs et sanstrous pour isoler les mains.

b. Faire trés attention de bien sʼisoler de la masse quand onsoude dans des endroits humides, ou sur un planchermetallique ou des grilles metalliques, principalement dansles positions assis ou couché pour lesquelles une grandepartie du corps peut être en contact avec la masse.

c. Maintenir le porte-électrode, la pince de masse, le câblede soudage et la machine à souder en bon et sûr étatdefonctionnement.

d.Ne jamais plonger le porte-électrode dans lʼeau pour lerefroidir.

e. Ne jamais toucher simultanément les parties sous tensiondes porte-électrodes connectés à deux machines à souderparce que la tension entre les deux pinces peut être letotal de la tension à vide des deux machines.

f. Si on utilise la machine à souder comme une source decourant pour soudage semi-automatique, ces precautionspour le porte-électrode sʼapplicuent aussi au pistolet desoudage.

2. Dans le cas de travail au dessus du niveau du sol, se protégercontre les chutes dans le cas ou on recoit un choc. Ne jamaisenrouler le câble-électrode autour de nʼimporte quelle partiedu corps.

3. Un coup dʼarc peut être plus sévère quʼun coup de soliel,donc:

a. Utiliser un bon masque avec un verre filtrant appropriéainsi quʼun verre blanc afin de se protéger les yeux du ray-onnement de lʼarc et des projections quand on soude ouquand on regarde lʼarc.

b. Porter des vêtements convenables afin de protéger lapeau de soudeur et des aides contre le rayonnement delʻarc.

c. Protéger lʼautre personnel travaillant à proximité ausoudage à lʼaide dʼécrans appropriés et non-inflammables.

4. Des gouttes de laitier en fusion sont émises de lʼarc desoudage. Se protéger avec des vêtements de protection libresde lʼhuile, tels que les gants en cuir, chemise épaisse, pan-talons sans revers, et chaussures montantes.

5. Toujours porter des lunettes de sécurité dans la zone desoudage. Utiliser des lunettes avec écrans lateraux dans les

zones où lʼon pique le laitier.

6. Eloigner les matériaux inflammables ou les recouvrir afin deprévenir tout risque dʼincendie dû aux étincelles.

7. Quand on ne soude pas, poser la pince à une endroit isolé dela masse. Un court-circuit accidental peut provoquer unéchauffement et un risque dʼincendie.

8. Sʼassurer que la masse est connectée le plus prés possiblede la zone de travail quʼil est pratique de le faire. Si on placela masse sur la charpente de la construction ou dʼautresendroits éloignés de la zone de travail, on augmente le risquede voir passer le courant de soudage par les chaines de lev-age, câbles de grue, ou autres circuits. Cela peut provoquerdes risques dʼincendie ou dʼechauffement des chaines et descâbles jusquʼà ce quʼils se rompent.

9. Assurer une ventilation suffisante dans la zone de soudage.Ceci est particuliérement important pour le soudage de tôlesgalvanisées plombées, ou cadmiées ou tout autre métal quiproduit des fumeés toxiques.

10. Ne pas souder en présence de vapeurs de chlore provenantdʼopérations de dégraissage, nettoyage ou pistolage. Lachaleur ou les rayons de lʼarc peuvent réagir avec les vapeursdu solvant pour produire du phosgéne (gas fortement toxique)ou autres produits irritants.

11. Pour obtenir de plus amples renseignements sur la sûreté,voir le code “Code for safety in welding and cutting” CSAStandard W 117.2-1974.

PRÉCAUTIONS DE SÛRETÉ POURLES MACHINES À SOUDER ÀTRANSFORMATEUR ET ÀREDRESSEUR

1. Relier à la terre le chassis du poste conformement au code delʼélectricité et aux recommendations du fabricant. Le dispositifde montage ou la piece à souder doit être branché à unebonne mise à la terre.

2. Autant que possible, Iʼinstallation et lʼentretien du poste seronteffectués par un électricien qualifié.

3. Avant de faires des travaux à lʼinterieur de poste, la debranch-er à lʼinterrupteur à la boite de fusibles.

4. Garder tous les couvercles et dispositifs de sûreté à leurplace.

Mar. ʻ93

SP-175 PLUS

Thank You for selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much pride as we have in bringing this product to you!

Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep ithandy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.The level of seriousness to be applied to each is explained below:

WARNINGThis statement appears where the information must be followed exactly to avoid serious personal injury orloss of life.

This statement appears where the information must be followed to avoid minor personal injury or damage tothis equipment.

CAUTION

Please Examine Carton and Equipment For Damage ImmediatelyWhen this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claimsfor material damaged in shipment must be made by the purchaser against the transportation company at thetime the shipment is received.

Please record your equipment identification information below for future reference. This information can befound on your machine nameplate.

Model Name & Number _____________________________________

Code & Serial Number _____________________________________

Date of Purchase _____________________________________

Whenever you request replacement parts for or information on this equipment always supply the informationyou have recorded above.

vv

vi vi

SP-175 PLUS

TABLE OF CONTENTS

Page

Installation .......................................................................................................Section ATechnical Specifications ........................................................................................A-1Identify and Locate Components ...........................................................................A-2Select Suitable Location ........................................................................................A-3Output Connections...............................................................................................A-3Input Connections..................................................................................................A-5Code Requirements ..............................................................................................A-6

Operation .........................................................................................................Section BSafety Precautions ................................................................................................B-1General Description ...............................................................................................B-2

Design Features and Advantages...................................................................B-2Welding Capability ..........................................................................................B-2Limitations .......................................................................................................B-2Controls and Settings......................................................................................B-2

Welding Operations ...............................................................................................B-3Overload Protection...............................................................................................B-7Learning to Weld....................................................................................................B-8Application Chart .................................................................................................B-19

Accessories .....................................................................................................Section CAccessories ...........................................................................................................C-1Replacement Parts ................................................................................................C-2

Maintenance ....................................................................................................Section DSafety Precautions ................................................................................................D-1Items Requiring No Maintenance ..........................................................................D-1Routine and Periodic Maintenance........................................................................D-1Gun and Cable Maintenance.................................................................................D-2Configuration of Components in Wire Feeding System.........................................D-2Component Replacement Procedures ..................................................................D-3

Troubleshooting ..............................................................................................Section ESafety Precautions.................................................................................................E-1How To Use Troubleshooting Guide......................................................................E-1Troubleshooting Guide ..........................................................................................E-2

Wiring Diagrams ..............................................................................................Section FSP-175 Plus Wiring Diagram ...............................................................................F-1

Parts Lists....................................................................................P331 Series & P202-E

A-1 A-1 INSTALLATION

SP-175 PLUS

TECHNICAL SPECIFICATIONS – SP-175 Plus

Fuse orOutput Mode Input Voltage Breaker Size Input Amps Power Cord

RATED 230V/60Hz 40 Super Lag 21/23 50 Amp, 250V,208V/60Hz Three-Prong Plug

(NEMA Type 6-50P)

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height Width Depth Weight12.0 in 9.75 in 16.5 in 60 Ibs305 mm 248 mm 419 mm 27.3 kg

PHYSICAL DIMENSIONS

Standard Voltage/Frequency Input Current230V/60Hz 21 Amps – Rated Output208V/60Hz 23 Amps – Rated Output

Duty Cycle Amps Volts at Rated Amperes30% Duty Cycle @ 230V/60Hz 130 2030% Duty Cycle @ 208V/60Hz 130 20

Welding Current Range Maximum Open Circuit Voltage Wire Speed RangeRated DC Output: 25 – 175 amps 33 50-400IPM (1.3-10.2m/min)

A-2 A-2 INSTALLATION

SP-175 PLUS

Read entire installation section before startinginstallation.

SAFETY PRECAUTIONS

IDENTIFY AND LOCATE COMPONENTS

If you have not already done so, unpack the SP-175Plus from its carton and remove all packing materialaround the SP-175 Plus . Remove the following looseitems from the carton (see Figure A.1):

1. SP-175 Plus

2. Gun and cable assembly(1)

3. Literature and miscellaneous including:

a) This operating manual

b) A contact tip for .030” (0.8 mm) diameter wire.

c) A contact tip for .035” (0.9 mm) diameter wire.

4. 10 ft (3.0 m) work cable.

5. Work clamp.

6. Sample Spool of L-56 .025 MIG Wire.

7. Adjustable mixed-Gas Regulator & Hose.

For available options and accessories refer to theaccessories section later in this manual.

1) As shipped from the factory, the SP-175 Plus gunliner is ready to feed .023” (0.6 mm) -.035 (0.9 mm)wire. The contact tip is sized for .025” (0.6 mm) wirefeeding.

ELECTRIC SHOCK can kill.

• Only qualified personnel should performthis installation.

• Only personnel that have read and under-stood the SP-175 Plus Operating Manualshould install and operate this equipment.

• Machine must be plugged into a receptaclewhich is grounded per any national, localor other applicable electrical codes.

• The SP-175 Plus power switch is to be inthe OFF (“O”) position when installingwork cable and gun and when connectingpower cord to input power.

WARNING

FIGURE A.1

12

3

4

5

SP-175 Plus

WELDING AMP RANGE-

WELDING AMP RANGE-

25-12525-125

6

7

A-3 A-3 INSTALLATION

SP-175 PLUS

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is freecirculation of clean air into the louvers in the back andleft side and out the front of the unit. A location thatminimizes the amount of smoke and dirt drawn intothe louvers reduces the chance of dirt accumulationthat can block air passages and cause overheating.

STACKING

SP-175 Plusʼ cannot be stacked.

TILTING

Each machine must be placed on a secure, level sur-face, or on a recommended undercarriage. Themachine may topple over if this procedure is not fol-lowed.

OUTPUT CONNECTIONS

Refer to Figure A.2.

1. Work Cable Access Hole.

2. Gun Cable and Control Lead Access Hole.

3. Connector Block.

4. Gun Trigger Lead Connectors.

5. Positive (+) and negative (–) output terminals.

6. Wire Feed Gearbox and Gun Connector Block

7. Cable Clamp

8. Thumbscrew - Secures gun and cable assembly

9. Optional Spot/Stitch Timer Kit see Accessories.

Work Clamp Installation

Attach the work clamp per the following:

1. Unplug the machine or turn the power switch to the“OFF” position.

2. Insert the work cable terminal lug with the largerhole through the strain relief hole in the work clampas shown in Figure A-3.

3. Fasten securely with the bolt and nut provided.

FIGURE A.3

Work Cable Installation

Refer to Figure A.2.

1. Open the wire feed section door on the right side ofthe SP-175 Plus .

2. Pass the end of the work cable that has the termi-nal lug with the smaller hole through the WorkCable Access Hole (1) in the case front.

Strain Relief Hole

Nut & Bolt

Work Clamp

Work Cable

FIGURE A.2

45

8

3 6 71 2

SP-175 PlusSP-175 Plus

WELDING AMP RANGE-WELDING AMP RANGE- 25-12525-125

+

-

9

A-4 A-4 INSTALLATION3. Route the cable under and around the back of the

Wire Feed Gearbox (6).

4. For GMAW Only: Refer to Figure A.2. As deliv-ered, the SP-175 Plus is wired for positive polarity.This is the appropriate configuration for the GasMetal Arc Welding (GMAW) process. To completeinstallation, use the provided wing nut to connectthe work cableʼs terminal lug to the negative (–)output terminal (5) located above the Wire FeedGearbox (6). Make sure that both wing nuts aretight.

5. For Innershield Only: Refer to Figure A.4. To wirefor negative polarity, connect the short cableattached to the connector block (1) to the negative(–) output terminal (2) and the work cable (3) to thepositive (+) terminal (4).

FIGURE A.4

3. Insert the connector on the gun conductor cablethrough the Gun Cable Access Hole (2) in the SP-175 Plus case front. Make sure the connector is allthe way in the metal connector block to obtainproper gas flow. Rotate the connector so controlleads are on the underside and tighten theThumbscrew (8) in the connector block.

4. Connect the gun trigger control lead terminals tothe two insulated 1/4" (6,4 mm) tab connectorbushings located above the “Gun TriggerConnection” decal in the wire feed section (4).Either lead can go to either connector. Form theleads so that they are as close as possible to theinside panel.

If the gun trigger switch being used is other thanthat supplied with the SP-175 Plus, the switchmust be a normally open, momentary switch. Theterminals of the switch must be insulated from thewelding circuit. Malfunction of the SP-175 Plus willresult if this switch shorts to the SP-175 Pluswelding output circuit or is common to any electri-cal circuit other than the SP-175 Plus triggercircuit.

GAS CONNECTION

Refer to Figure A.5

When using the GMAW process, a cylinder of shield-ing gas, must be obtained. For more information aboutselecting gas cylinders for use with the SP-175 Plus,refer to the ACCESSORIES section.

CYLINDER may explode if dam-aged. Keep cylinder upright andchained to support

• Keep cylinder away from areaswhere it may be damaged.

• Never lift welder with cylinderattached.

• Never allow welding electrode totouch cylinder.

• Keep cylinder away from weldingor other live electrical circuits.

GUN INSTALLATION

As shipped from the factory, the SP-175 Plus gun lineris ready to feed 0.023 - 0.035” (0.6 - 0.9 mm) wire. If0.025” (0.6 mm) or 0.030” (0.8 mm) wire is to be usedinstall the 0.025” (0.6 mm) or 0.30” (0.8 mm) contacttip. Refer to the MAINTENANCE section for contact tipinstallation details.

Connecting Gun Cable to the SP-175 Plus

1. Refer to Figure A.2. Unplug the machine or turnpower switch to the off “O” position.

2. Pass the insulated terminals of the gun trigger con-trol leads, one at a time, through the Gun Cableand Control Lead Access Slot (2) in the case front.The leads are to be routed under the Wire FeedGearbox (6) and through the Cable Hanger (7) onthe inner panel.

CAUTION

WARNING

1

2

34

SP-175 PLUS

A-5 A-5 INSTALLATION

SP-175 PLUS

3. Attach the flow regulator to the cylinder valve andtighten the union nut securely with a wrench. Theflow regulator for carbon dioxide must have a plas-tic washer seated in the fitting that attaches to thecylinder to prevent leakage. Refer to K1800-1 inthe accessories section.

4. Refer to Figure A.6. Attach one end of inlet gashose to the outlet fitting of the flow regulator andtighten the union nut securely with a wrench.Connect the other end to the SP-175 Plus GasSolenoid Inlet Fitting (5/8-18 female threads — forCGA — 032 fitting). Make certain the gas hose isnot kinked or twisted.

INPUT CONNECTIONS

Refer to Figure A.6.

The SP-175 Plus has two input connections, thepower input cable, and the Gas Solenoid Inlet Fitting.Both connections are located on the rear of themachine.

FIGURE A.6

BUILDUP OF SHIELDING GAS mayharm health or kill.

• Shut off shielding gas supplywhen not in use.

• SEE AMERICAN NATIONALSTANDARD Z-49.1, “SAFETY INWELDING AND CUTTING” PUB-LISHED BY THE AMERICANWELDING SOCIETY.

1. Chain the cylinder to a wall or other stationary sup-port to prevent the cylinder from falling over.Insulate the cylinder from the work circuit and earthground.

FIGURE A.5

2. With the cylinder securely installed, remove thecylinder cap. Stand to one side away from the out-let and open the cylinder valve very slightly for aninstant. This blows away any dust or dirt which mayhave accumulated in the valve outlet.

BE SURE TO KEEP YOUR FACE AWAY FROM THEVALVE OUTLET WHEN “CRACKING” THE VALVE.Never stand directly in front of or behind the flowregulator when opening the cylinder valve. Alwaysstand to one side.

WARNING

WARNING

Cylinder Valve

Gas Hose

Flow Regulator

Gas SolenoidInlet Fitting

PowerInputCable

A-6 A-6 INSTALLATIONLine Cord Connection

A 3 conductor line cord with a 50 amp, 250 volt, three-prong plug (NEMA Type 6-50P) is factory installed.Connect this plug to a mating grounded receptaclewhich is connected to an appropriate power supplyper the U.S. National Electric Code and any applicablelocal codes.

CONNECT TO A SYSTEMGROUNDING WIRE. SEETHE UNITED STATESNATIONAL ELECTRICALCODE AND/OR LOCALCODES FOR OTHERDETAILS AND MEANS FORPROPER GROUNDING.

CONNECT TO HOT WIRES OF A THREE-WIRE SINGLEPHASE SYSTEM OR TOONE PHASE OF A TWO ORTHREE PHASE SYSTEM.

This welding machine must be connected to apower source in accordance with applicable elec-trical codes.

The United States National Electrical Code (Article630-B, 1990 Edition) provides standards foramperage handling capability of supply conduc-tors based on duty cycle of the welding source.

If there is any question about the installationmeeting applicable electrical code requirements,consult a qualified electrician.

ELECTRICAL INPUT CONNECTION FORRATED OUTPUT

ELECTRIC SHOCK can kill.

• Disconnect input power by removingplug from receptacle before workinginside SP-175 Plus.

• Use only grounded receptacle.

• Do not touch electrically “hot” partsinside SP-175 Plus.

• Have qualified personnel do the main-tenance and troubleshooting work.

230 Volt Input Connection

The SP-175 Plus is shipped from the factory connect-ed for 230 volt input power. If the welder has beenreconnected for 208 volt input power and 230 voltinput is desired, perform the following reconnectioninstructions:

1. Disconnect welder from input power and removecase side panel.

2. Remove lead marked “H3” from H1 terminal on thecontrol P.C. Board.

3. Remove tape securing H1 lead to lead sleevingand connect H1 lead to H1 terminal on the board.

4. Insulate unused H3 lead for 300 volts with electri-cal tape and secure to lead sleeving.

5. Reinstall case side before connecting input power.

208 Volt Input Connection

1. Disconnect welder from input power and removecase side.

2. Remove lead marked “H1” from H1 terminal on thecontrol P.C. Board.

3. Remove tape securing H3 lead to lead sleevingand connect H3 lead to H1 terminal on the board.

4. Insulate unused H1 lead for 300V with electricaltape and secure to lead sleeving.

5. Reinstall case side before connecting input power.

WARNING

GroundingType 75°C Wire Fuse

Wire in Conduit, Copper SizeInput Copper Cond. Cond. (Super

Voltage Hertz AWG Size AWG Size Lag)

208/230 60 8 10 40

WARNING

SP-175 PLUS

B-1

SP-175 PLUS

B-1 OPERATION

Read entire Operation section beforeoperating the SP-175 Plus.

ELECTRIC SHOCK can kill.• Do not touch electrically live

parts or electrode with skin orwet clothing. Insulate yourselffrom work and ground.

• Always wear dry insulatinggloves.

FUMES AND GASES can bedangerous.• Keep your head out of fumes.

• Use ventilation or exhaust toremove fumes from breathingzone.

WELDING SPARKS cancause fire or explosion.• Keep flammable material away.

• Do not weld on closed contain-ers.

ARC RAYS can burn eyesand skin.• Wear eye, ear and body protec-

tion.

Observe all safety information throughoutthis manual.

WARNING

B-2 B-2 OPERATIONGENERAL DESCRIPTION

The SP-175 Plus is a complete semiautomatic constant volt-age DC arc welding machine. Included is a continuous con-trolled, single phase constant voltage transformer/rectifierpower source and a wire feeder with welding gun for feeding.023” (0.6 mm) through .035” (0.9 mm) solid steel electrode.Optional kits are available for .035” (0.9 mm) and .045” (1.2mm) Innershield® NR-211-MP cored wire and .035” alu-minum wire.

The SP-175 Plus is ideally suited for individuals havingaccess to 230 or 208 volt 60 Hz AC input power, and wanti-ng the ease of use, quality and dependability of both gasmetal arc welding or GMAW (also known as MIG welding)and the Innershield electrode process (self shielded fluxcored or FCAW). A convenient chart is mounted inside thewire feed section door for setting welding procedures for 24gauge (.60 mm) through 5/16” (8.0 mm) mild steel. The SP-175 Plus is a rugged and reliable machine that has beendesigned for dependable service and long life.

RECOMMENDED PROCESSES

The SP-175 Plus can be used for welding mild steel usingthe GMAW, single pass, process which requires a supply ofshielding gas or it can be used for the self shielded,Innershield electrode process (FCAW). The SP-175 Plus isconfigured for use with the GMAW (MIG) process as deliv-ered from the factory.

OPERATIONAL FEATURES AND CONTROLS

The SP-175 Plus has the following controls as standard:Power ON/OFF Switch, Voltage Control, Wire SpeedControl, and a Circuit Breaker.

DESIGN FEATURES AND ADVANTAGES

● Reconnectable for 230 volt or 208 volt single phase 60Hz input power.

● Solid state output control.

● “Cold electrode” until gun trigger is pressed for an addedmeasure of safety.

● Overload protection — incorporates both a thermostatand a circuit breaker.

● Quality wire drive with electronic overload protection.

● Easy-to-set continuous range controls for precise settingof arc voltage and wire speed.

● “Quick Release” idle roll pressure arm is easily adjusted.

● Reversible, dual groove drive roll. Drive roll will feed.023-.035” (0.6- 0.9 mm) diameter wire.

● Accommodates both 8” (200 mm) diameter and 4” (100mm) diameter spools of wire.

● No external shielding gas is required when used withLincoln Innershield .035” (0,9 mm) NR®-211-MP elec-trode.

● Easy to change polarity. (No tools required)

● Accepts optional Spot/Stitch Timer Kit.

WELDING CAPABILITY

The SP-175 Plus, as shipped, is rated at 130 amps, 20volts, at 30% duty cycle on a ten minute basis. It is capableof higher duty cycles at lower output currents.

LIMITATIONS

Arc Gouging cannot be performed with the SP-175Plus. The SP-175 Plus is not recommended for pipethawing or TIG welding.

CONTROLS AND SETTINGS

Refer to Figures B.1a & B.1b.

1. Power ON/OFF Switch —When the power is on thefan motor will run and air willbe exhausted out the louversin the front of the machine.The welding output and wirefeeder remain off until thegun trigger is pressed.

2. Voltage Control — A contin-uous control that gives fullrange adjustment of powersource output voltage.Voltage can be adjustedwhile welding.

3. Wire Speed Control —Controls the wire feed speedfrom 50 – 400 in /min (1.3 –10 m/min). The control canbe preset on the dial to thesetting specified on the SP-175 Plus Application Chartlocated on the inside of thewire feed section door. Wirespeed is not affected whenchanges are made in thevoltage control.

OFF

ON

ARC VOLTS

WIRE SPEED

ON

ARC VOLTS

SP-175 PLUS

WELDING OPERATIONS

SEQUENCE OF OPERATION

Wire LoadingRefer to Figure B.2 and B.3.The machine power switch should be turned to theOFF (“O”) position before working inside the wire feedenclosure.

The machine is shipped from the factory ready to feed8” (200 mm) diameter spools [2.2” (56 mm) max.width]. These spools fit on a 2” (50 mm) diameterspindle that has a built-in adjustable friction brake toprevent overrun of the spool and excess slack in thewire.

Note:When loading and removing the 8” Spools makesure that the wing nut (inside the wire spool spindlehub) is turned 90° from the wire spool spindle lockingtab. If the wing nut is positioned in line with the lockingtab, the tab cannot be depressed to load or unload thewire spool.

Load an 8” (200 mm) diameter spool on the wire spoolspindle shown in Figure B.2.

To use 4” (100 mm) diameter spools, the 2” (50 mm)diameter spindle must be removed (See Figure B.3).Remove the wing nut and spacer at the end of theshaft and remove the outside plastic wire spool spin-dle. The spindle can be stored in the wire feed com-partment. A 4” (100 mm) diameter spool is mounteddirectly on the 5/8” (16 mm) diameter shaft and held inplace with the previously removed hardware. Alsomake certain the start end of the wire, which may pro-trude through the side of the spool does not contactany metallic case parts.

FIGURE B.2

B-3

SP-175 PLUS

B-3 OPERATION

FIGURE B.1a

Refer to Figure B.1b

4. Circuit Breaker – Protects machine from damage ifmaximum output is exceeded. Button will extendout when tripped (Manual reset).

5. Optional K695-2 Spot/Stitch Controls (see ACCES-SORIES section) - If present, replaces Blank PanelAssembly located on the center panel inside thecase door:

Mode Switch - Selects between Spot, Stitch, orSeam (normal welding) mode. Spot mode welds foran adjustable length of time (set by Time Control;see below) and then stops, whenever the gun trig-ger is depressed and held. Stitch mode cyclesbetween welding and not welding for an adjustablelength of time (also set by Time Control) while thegun trigger is depressed. In Seam mode themachine will weld continuously while the gun trig-ger is depressed. Releasing the gun trigger in anyof the three modes will interrupt welding immedi-ately.

Time Control - In Spot mode, controls spot modeON time between approximately .25 and 4.0 sec-onds. In Stitch mode, controls stitch mode ON timeand OFF time simultaneously between .25 and 4.0seconds each. This control is deactivated while inSeam mode.

FIGURE B.1b

1

SP-175 PlusSP-175 Plus

WELDING AMP RANGE-WELDING AMP RANGE- 25-12525-125

3

2

4

5

To wire drive

Wire Spool must be pushed all the way on the spindle so that thespindleʼs tab will hold it in place. The Wire Spool must rotate clock-wise when wire is dereeled.

Wire Spool Spindle

Thumb Screw

Be sure that this stud engagesthe hole in the wire spool.

Locking Tab

8” Wire Spool

B-4

SP-175 PLUS

B-4 OPERATION

Note: The brake should be adjusted with a spool ofwire installed. When properly adjusted it shouldmove freely but not coast.

Friction Brake Adjustments

1. With wire spool installed, check free movementand coast of the spool.

2. To tighten the brake turn the wing nut clockwise in1/4 turn increments until coasting stops.

3. To loosen the brake turn the wing nut counter-clockwise in 1/4 turn increments until the wire spoolmoves freely without coasting.

Wire Threading Refer to Figure B.4

1. Release the Spring Loaded Pressure Arm (1)rotate the Idle Roll Arm (2) away from the WireFeed Drive Roll (3). Ensure that the visible, sten-ciled size on the drive roll matches the wire sizebeing used.

2. Carefully detach the end of the wire from thespool. To prevent the spool from unwinding, donot release the wire until after step 5.

3. Cut the bent portion of wire off and straighten thefirst 4” (100 mm).

4. Thread the wire through the In-going guide tube(4), over the drive roll (3), and into the out-goingguide tube (5).

5. Close the idle roll arm and latch the spring loadedpressure arm (2) in place (now you may releasethe welding wire).

6. The idle roll pressure adjustment wing nut is nor-mally set for mid-position on the pressure armthreads. If feeding problems occur because thewire is flattened excessively, turn the pressureadjustment counter-clockwise to reduce distortionof the wire. Slightly less pressure may be requiredwhen using 0.023 – 0.025” (0,6 mm) wire. If thedrive roll slips while feeding wire, the pressureshould be increased until the wire feeds properly.

When inching the welding wire, the drive rolls, thegun connector block and the gun contact tip arealways energized relative to work and ground andremain energized several seconds after the guntrigger is released.

7. Refer to Figure B.5. Remove (unscrew) gas noz-zle and contact tip from end of gun.

8. Turn the SP-175 Plus ON (“I”).

9. Straighten the gun cable assembly.

10. Depress the gun trigger switch and feed weldingwire through the gun and cable. (Point gun awayfrom yourself and others while feeding wire.)Release gun trigger after wire appears at end ofgun.

11. Replace contact tip and gas nozzle.

12. Refer to Figure B-6. Cut the wire off 1/4” – 3/8”(6 – 10 mm) from the end of the tip. The SP-175Plus is now ready to weld.

Wire Spindle Shaft 4" Wire Spool

Wing Nut and Spacer

To wire drive

FIGURE B.4

The Wire Drive Feed Roll canaccommodate two wire sizes byflipping the wire drive feed rollover. The sizes are stenciled onthe drive roll.

1

2

345

WARNING

B-5 B-5 OPERATION

Shielding GasWhen using the GMAW process, a cylinder of shield-ing gas, must be obtained. Refer to the ACCES-SORIES section for more information about selectinggas cylinders for use with the SP-175 Plus. Be sureto observe all cylinder handling and use precau-tions.

1. For CO2, open the cylinder very slowly. For argon-mixed gas, open cylinder valve slowly a fraction ofa turn. When the cylinder pressure gauge pointerstops moving, open the valve fully.

2. If using a regulator with an adjustable flow meter,press the gun trigger and adjust the flow to give 15– 20 cubic ft per hour (CFH) (7 – 10 I/min) [use 20-– 25 CFH (10 – 12 I/min) when welding out ofposition or in a drafty location for CO2]. For argonmixed gas, press the gun trigger to release gaspressure, and adjust the flow to give 25 – 30 CFH(12 – 14 I/min).

3. Keep the cylinder valve closed, except when usingthe SP-175 Plus. When finished welding:

a) Close the cylinder valve to stop gas flow.

b) Depress the gun trigger briefly to release thepressure in the gas hose.

c) Turn off the SP-175 Plus.

Making A Weld1. See Recommended Processes And Equipment

section for selection of welding wire and shieldinggas and for range of metal thicknesses that can bewelded.

2. See the Application Chart on the inside of wirefeed section door for information on setting theSP-175 Plus controls.

3. Set the Voltage (“V”) and Wire Speed (“oloʼ”) con-trols to the settings suggested for the welding wireand base metal thickness being used.

FIGURE B.6FIGURE B.5

Gun Handle

Gas Diffuser/Contact Tip

Gas Nozzle

4. Check that the polarity is correct for the weldingwire being used and that the gas supply, ifrequired, is turned on.

5. When using Innershield electrode, remove the gasnozzle and install the gasless nozzle. This willimprove visibility of the arc and protect the gas dif-fuser from weld spatter. Refer to the MAINTE-NANCE section for details on nozzle replacement.

6. Refer to Figure B.7. Connect work clamp to metalto be welded. Work clamp must make good elec-trical contact to the workpiece. The workpiecemust also be grounded as stated in “Arc WeldingSafety Precautions” in the beginning of this manu-al.

7. Position gun over joint. End of wire may be lightlytouching the work.

8. Lower welding helmet, close gun trigger, andbegin welding. Hold the gun so the contact tip towork distance is about 3/8 inch (10 mm).

3/8" – 1/2" Electrical Stickout

Contact Tip

Wire Electrode

FIGURE B.7

WORKPIECE

GUN CABLE

ARC

WORK CLAMP

SP-175 PlusSP-175 Plus

SP-175 PLUS

B-6 B-6 OPERATION9. To stop welding, release the gun trigger and then

pull the gun away from the work after the arc goesout.

10. When no more welding is to be done, close valveon gas cylinder (if used), momentarily operate guntrigger to release gas pressure, and turn off theSP-175 Plus.

Cleaning Tip And NozzleClean the contact tip and nozzle to avoid arc bridgingbetween the nozzle and contact tip which can result ina shorted nozzle, poor welds and an overheated gun.Hint: Anti-stick spray or gel, available from a weldingsupply distributor, may reduce buildup and aid in spat-ter removal.

PROCESS GUIDELINES

The SP-175 Plus can be used for welding mild steelusing the GMAW, single pass, process which requiresa supply of shielding gas or it can be used for the selfshielded, Innershield electrode process.

The recommended gas and electrode for GMAW iswelding grade mixed CO2 and Argon (75-80%) gasand 0.025” (0 6 mm) diameter Lincoln L-56 mild-steelwelding wire [supplied on 121/2 Ib (6 kg) spools]. For14 gauge (2,0 mm) and thinner CO2, or blended gas isacceptable. A mixed gas consisting of 75 to 80%Argon and 20 to 25% CO2 is recommended for weld-ing on heavier gauge [12 gauge (2,5 mm) for example]steel.

The recommended electrode for the self-shieldedprocess is 0.035” (0,9 mm) diameter LincolnInnershield NR-211-MP on 10 Ib (4,5 kg) spools. Thiselectrode can be used for all position welding of 20gauge through 5/16” (1,0 – 8,0 mm) thick steel [multi-ple passes are required for 1/4” and 5/16” (6,0 and 8,0mm)].

The SP-175 Plus is suitable for .035" Aluminum wireand .030"-.035” stainless wire. Refer to Table B.1 forRecommended Procedure Settings. Aluminum wirerequires an Aluminum Welding kit. See ACCES-SORIES section.

It is important when changing between weldingwith steel wire and aluminum to exchange feedingcomponents due to the lubricant applied to steelwire. Failure to do so may result in contaminatedwelds when welding aluminum.------------------------------------------------------------------------

TABLE B.1 — SP-175 Plus Welding Procedures

CHANGING MACHINE OVER TOFEED OTHER WIRE SIZES

The SP-175 Plus is shipped from the factory with agun liner ready to feed 0.023-0.035” (0.6-0.9 mm)diameter wire. The contact tip is 0.025” (0.6 mm) andthe drive roll is set for 0.023”-0.025” (0.6 mm). Tooperate the SP-175 Plus with other sizes of wire, it isnecessary to change the contact tip and change thedrive roll over to other sizes. Refer to Changing theContact Tip and Changing the Drive Roll, in the MAIN-TENANCE section, for specific information on theseprocedures.

WELDING WITH FCAW (Innershield)

Welding with Innershield requires an InnershieldWelding Kit. A gasless nozzle is provided in theInnershield Welding Kit. When using Innershield elec-trode, installing the gasless nozzle will improve visibili-ty of the arc and protect the gas diffuser from weldspatter. Additionally included is a gun cable liner topermit proper feeding of .035” (0,9 mm) Innershieldwire. Refer to the ACCESSORIES section for detailson obtaining this kit.

Welding ShieldingProcess Wire Gas 16 ga 14 ga 12 ga 10 ga 3/16

MIG DC+ .035 Dia 100% Argon C-7 D-9 F-9 G-9 I-104043/5356Alum. Wire

MIG DC+ .030 Dia 90% Helium/F-6 G-7 H-8 I-9 I-9308L Stainless 7.5% Argon/

Steel Wire 2.5% CO2

MIG DC+ .035 Dia 90% Helium/G-6 H-7 I-8 J-9 J-9308L Stainless 7.5% Argon/

Steel Wire 2.5% CO2

WARNING

Use of the GMAW process with the SP-175 Plus onthicker materials than 5/16” (8.0 mm) may result inpoor welds. The welds may “look” good, but mayjust be “sitting” on top of the plate. This is called“cold casting” and will result in weld failure.

CAUTION

SP-175 PLUS

SP-175 PLUS

B-7 OPERATION

OVERLOAD PROTECTION

Output OverloadThe SP-175 Plus is equipped with a circuit breakerwhich protects the machine from potential damagefrom excessive output current. The circuit breaker but-ton will extend out when tripped. The circuit breakermust be manually reset.

Thermal ProtectionThe SP-175 Plus duty cycle is exceeded a thermostatwill shut off the output until the machine cools to a nor-mal operating temperature. This is an automatic func-tion and is self resetting.

Wire Feed Overload ProtectionIf the SP-175 Plus has an automatic electronic protec-tion circuit to protect the wire feed motor. If excessivemotor overload occurs (due to excessive feeding forcejammed drive rolls, or shorted motor leads) the circuitwill shut down the wire feed motor and the weldingpower output.

The wire feed shut-down circuit will reset automaticallywhen the gun trigger is released. However shut-downwill reoccur if the overload situation is not corrected.

B-7

B-8 B-8 LEARNING TO WELDLEARNING TO WELD

No one can learn to weld simply by reading about it.Skill comes only with practice. The following pages willhelp the inexperienced operator to understand weld-ing and develop this skill. For more detailed informa-tion, order a copy of “New Lessons in Arc Welding”listed at the end of this manual.

THE ARC-WELDING CIRCUIT

The operatorʼs knowledge of arc welding must gobeyond the arc itself. The operator must know how tocontrol the arc, and this requires a knowledge of thewelding circuit and the equipment that provides theelectric current used in the arc. Figure B.7 illustratesthe welding circuit for a typical welding machine. Thecircuit begins where the gun cable is attached to thewelding machine. Current flows through the gun cable,gun, and contact tip, to the wire and across the arc.On the work side of the arc, current flows through thebase metal to the work cable and back to the weldingmachine. This circuit must be complete for the currentto flow.

This machineʼs welding circuit has a voltage output of33 volts DC maximum. This voltage is quite low and isonly present when the gun trigger is depressed.

To weld, the work clamp must be tightly connected toclean base metal. Remove paint, rust, dirt or oil asnecessary and connect the work clamp as close aspossible to the area you wish to weld. This helps pre-vent current from going through an unwanted path.Avoid allowing the welding circuit to pass throughhinges, bearings, electronic components, or similardevices that can be damaged. See Figure B.8. Alwaysdisconnect electrical devices before welding uponthem.

Fumes and slag generated fromInnershield type electrodes recom-mended for use with this weldingmachine can be toxic.

• Avoid contact with eyes and skin.

• Do not take internally.

• Keep out of reach of children.

• Follow all safety precautionsfound in this operating manual.

The gun and cable assembly is held by the operatorwho guides the automatically fed wire along the joint,maintaining a contact tip to work distance of about 3/8to 1/2 inch (10 – 12 mm). This is called electrical stick-out. This electrical stickout (ESO) must be properlymaintained by the operator. The electric arc is made inthe gap between the work and the tip end of a smalldiameter wire. When the power source is properly set,the arc gap is maintained automatically.

Arc welding is a manual skill requiring a steady hand,good physical condition, and good eyesight. The oper-ator controls the welding arc, and therefore, the qualityof the weld made.

THE SELF-SHIELDED FCAW WELDINGARC

Figure B.9 illustrates the action taking place in the selfshielded FCAW (Innershield) welding arc. It closelyresembles what is actually seen while welding.

FIGURE B.9

WARNING

FIGURE B.8

Electronic Components

Hinges Bearings

Burning of core materialsinside wire electroderesults in shield of gas.

Arc Stream

Cored Wire

Protective Slag

Weld Metal

SP-175 PLUS

B-9

SP-175 PLUS

B-9 LEARNING TO WELDThe “arc stream” is seen in the middle of the picture.This is the electric arc created by the electric currentflowing through the space between the end of the wireelectrode and the base metal. The temperature of thisarc is about 6000°F, which is more than enough tomelt metal. The arc is very bright, as well as hot, andcannot be looked at with the naked eye without riskingpainful injury. The very dark lens, specif icallydesigned for arc welding must be used with the handor face shield whenever viewing the arc.

The arc melts the base metal and actually digs into itmuch as water through a nozzle on a garden hosedigs into the earth. The molten metal forms a moltenpool or crater and tends to flow away from the arc. Asit moves away from the arc, it cools and solidifies.

The function of the Innershield cored wire electrode ismuch more than simply to carry current to the arc. Thewire core is composed of fluxes and/or alloying ingre-dients around which a steel sheath has been formed.It is simply a stick electrode turned inside out in a con-tinuous wire form.

The cored wire melts in the arc and tiny droplets ofmolten metal shoot across the arc into the moltenpool. The wire sheath provides additional filler metalfor the joint to fill the groove or gap between the twopieces of base metal.

The core materials also melt or burn in the arc andperform several functions. They make the arc stead-ier, provide a shield of smoke-like gas around the arcto keep oxygen and nitrogen in the air away from themolten metal, and provide a flux for the molten pool.The flux picks up impurities and forms the protectiveslag on top of the weld during cooling.

After running a weld bead, the slag may be removedwith a chipping hammer and wire brush. Thisimproves appearance and allows for inspection of thefinished weld.

Since machine size and output characteristics limit thesize and type of wire electrode which can be used,Lincoln 0.035" and 0.045" (0.9 and 1.2 mm) NR-211-MP Innershield electrode is recommended for Self-Shielded Flux Cored Arc Welding with this machine.

THE GMAW (MIG) WELDING ARC

Figure B.10 illustrates the GMAW (MIG) welding arc.Solid wire does not contain fluxes or ingredients toform its own shielding and no slag forms to protect themolten weld metal. For this reason, a continuous evenflow of shielding gas is needed to protect the moltenweld metal from atmospheric contaminants such asoxygen and nitrogen. Shielding gas is suppliedthrough the gun and cable assembly, through the gasnozzle and into the welding zone.

When comparing the GMAW and FCAW processes,you can see that the principal difference between thetwo lies in the type of shielding used. GMAW uses gasfor shielding, thus we have Gas Metal Arc Welding.FCAW uses the melting or burning of the core ingredi-ents for shielding, and is thus termed Self-ShieldedFlux Cored Arc Welding.

The recommended wire for Gas Metal Arc Welding(MIG) is Lincolnweld 0.025” (0.6 mm) L-56 electrode.Lincolnweld” L-56 is capable of welding a wide rangeof mild steels in all positions, however, more skill isrequired for out-of-position welding with the GMAWprocess.

PROCESS SELECTION

By gaining knowledge of the differences between thetwo processes, you will be able to select the bestprocess for the job you have at hand. In selecting aprocess, you should consider:

For GMAW (MIG) Process1. Is most of my welding performed on 16 gauge and

lighter materials?

FIGURE B.10

Gas nozzle

Shielding gasSolid wireelectrode

Base metalWeld metal

B-10

SP-125 PLUS

B-10 LEARNING TO WELD2. Can I afford the extra expense, space, and lack of

portability required for gas cylinders and gas sup-ply?

3. Do I require clean, finished-looking welds?

If you have answered yes to all the above questionsGMAW may be the process for you. If you haveanswered no to any of the above questions, then youshould consider using the FCAW process.

For FCAW (Innershield) Process1. Do I want simplicity and portability?

2. Will welding be performed outdoors or under windyconditions?

3. Do I require good all position welding capability?

4. Will most welding be performed on 16 gauge andheavier, somewhat rusty or dirty materials?

5. Weld must be cleaned prior to painting.

COMMON METALS

Most metals found around the farm, small shop orhome are low carbon steel, sometimes referred to asmild steel. Typical items made with this type of steelinclude most sheet metal, plate, pipe and rolledshapes such as channels and angle irons. This type ofsteel can usually be easily welded without special pre-cautions. Some steels, however, contain higher car-bon levels or other alloys and are more difficult toweld. Basically, if a magnet sticks to the metal andyou can easily cut the metal with a file, chances aregood that the metal is mild steel and that you will beable to weld the material. In addition, aluminum andstainless steel can be welded using an aluminumwelding kit. For further information on identifying vari-ous types of steels and other metals, and for properprocedures for welding them, we again suggest youpurchase a copy of “New Lessons in Arc Welding”.

Regardless of the type of metal being welded, in orderto get a quality weld, it is important that the metal isfree of oil, paint, rust or other contaminants.

JOINT TYPES AND POSITIONS

Five types of welding joints are: Butt Welds, FilletWelds, Lap Welds, Edge Welds and Corner Welds.See Figure B.11.

Of these, the Butt Weld and Fillet Weld are the twomost common welds.

FIGURE B.11

Butt WeldsPlace two plates side by side, leaving a space approx-imately one half the thickness of the metal betweenthem in order to get deeper penetration.

Securely clamp or tack weld the plates at both ends,otherwise the heat will cause the plates to move apart.See Figure B.12.

Now weld the two plates together. Weld from left toright (if right handed). Point the wire electrode down inthe crack between the two plates, keeping the gunslightly tilted in the direction of travel. Watch themolten metal to be sure it distributes itself evenly onboth edges and in between the plates. This is referedto as the “pull technique”. On thin gauge sheet metal,use the “push technique”. See “Welding Techniquesfor GMAW (MIG) Process”.

Butt weld Lap weld

Edge weld Fillet weld Corner weld

B-11

SP-175 PLUS

B-11 LEARNING TO WELD

FIGURE B.12PenetrationUnless a weld penetrates close to 100% of the metalthickness, a butt weld will be weaker than the materialwelded together. In the example shown in FigureB.13, the total weld is only half the thickness of thematerial thus the weld is only approximately half asstrong as the metal.

FIGURE B.13

FIGURE B.14

In the example shown in Figure B.14, the joint hasbeen welded so that 100% penetration could beachieved. The weld, if properly made, is as strong asor stronger than the original metal.

Fillet WeldsWhen welding fillet welds, it is very important to holdthe wire electrode at a 45° angle between the twosides or the metal will not distribute itself evenly. Thegun nozzle is generally formed at an angle to facilitatethis. See Figure B.15.

FIGURE B.15

Welding In The Vertical Position

Welding in the vertical position can be done either ver-tical-up or vertical-down. Vertical-up is used whenevera larger, stronger weld is desired. Vertical-down isused primarily on sheet metal 5/32” (3.9 mm) andunder for fast, low penetrating welds.

Use of this unit on thicker materials than recom-mended may result in poor welds. The welds may“look” good, but may just be “sitting” on top, ofthe plate. This is called “Cold Casting” and willresult in weld failure.

Vertical-up And Overhead WeldingThe problem, when welding vertical-up, is to put themolten metal where it is wanted and make it staythere. If too much molten metal is deposited, gravitywill pull it downwards and make it “drip”. Therefore, acertain technique has to be followed.

When welding out-of-position, run stringer beads.Donʼt whip, break the arc, move out of the puddle, ormove too fast in any direction. Use Wire Feed Speed(WFS) in the low portion of the range. The generaltechnique and proper gun angle is illustrated in FigureB.16.

Generally, keep the electrode nearly perpendicular tothe joint as illustrated. The maximum angle above per-pendicular may be required if porosity becomes aproblem.

45°

WARNING

B-12

SP-175 PLUS

B-12 LEARNING TO WELD

FIGURE B.16

Vertical-down WeldingRefer to Figure B.17 Vertical-down welds are appliedat a fast pace. These welds are therefore shallow andnarrow and, as such, are excellent for sheet metal.Vertical-down welds may be applied to 5/32” (3.9 mm)and lighter material.

Use stringer beads and tip the gun in the direction oftravel so the arc force helps hold the molten metal inthe joint. Move as fast as possible consistent withdesired bead shape.

The important thing is to continue lowering the entirearm as the weld is made so the angle of the gun doesnot change. Move the electrode wire fast enough thatthe slag does not catch up with the arc. Vertical-downwelding gives thin, shallow welds. It should not beused on heavy material where large welds arerequired.

FIGURE B.17

PROPER GUN ANGLE FOR GMAW PROCESS WELDING IN THE VERTICAL UP POSITION

PROPER GUN ANGLE FOR FCAW PROCESS WELDING IN THE VERTICAL UP POSITION

MACHINE SET UP FOR THE SELF-SHIELDED FCAW PROCESS

1. See PROCESS GUIDELINES in the OPERATIONsection for selection of welding wire and shieldinggas, and for range of metal thicknesses that can bewelded.

2. See the Application Guide on the inside of wirefeed section door for information on setting thecontrols.

3. Set the “Voltage” and “Wire Speed” controls to thesettings suggested on the Application Guide for thewelding wire and base metal thickness being used.The voltage control is marked “V” and the wire feedspeed is marked ʻʼolo.ʼʼ

4. Check that the polarity is correct for the weldingwire being used. Set the polarity for DC(–) whenwelding with NR-211-MP Innershield electrode.See Work Cable Installation in the INSTALLATIONsection for instructions on changing polarity.

5. When using Innershield electrode, the gasless noz-zle may be used instead of a gas nozzle to improvevisibility of the arc.

6. Connect work clamp to metal to be welded. Workclamp must make good electrical contact to thework piece. The work piece must also be groundedas stated in the “Arc Welding Safety Precautions”at the beginning of this manual.

WELDING TECHNIQUES FOR THE SELF-SHIELDED FCAW PROCESS

Four simple manipulations are of prime importancewhen welding. With complete mastery of the four,welding will be easy. They are as follows:

1. The Correct Welding PositionFigure B.18 illustrates the correct welding positionfor right handed people. (For left handed people, itis the opposite.)

Hold the gun (of the gun and cable assembly) inyour right hand and hold the shield with your lefthand. (Left handers simply do the opposite.)

When using the FCAW Process, weld from left toright (if you are right handed). This enables you toclearly see what you are doing. (Left handers dothe opposite.) Tilt the gun toward the direction oftravel holding the electrode at an angle as shownin Figure B.18.

B-13

SP-175 PLUS

B-13 LEARNING TO WELD

ARC RAYS can burn eyes and skin.

When using an open arc process, itIs necessary to use correct eye,head and body protection.

Protect yourself and others, read“ARC RAYS can burn” at the frontof this manual.

2. The Correct Way To Strike An Arc1. Be sure the work clamp makes good electrical

contact to the work.

2. Position gun over joint. End of wire may belightly touching the work.

3. Position face shield to protect face and eyes,close gun trigger, and begin welding. Hold thegun so that the contact tip to work distance isabout 3/8 to 1/2 inch (10 – 12 mm).

4. To stop welding, release the gun trigger andthe pull the gun away from the work after thearc goes out.

5. A ball may form at the tip end of the wire afterwelding. For easier restrikes (with Innershieldwire) the ball may be removed by feeding out afew inches of wire and simply bending the wireback and forth until it breaks off.

6. When no more welding is to be done, turn offthe machine.

3. The Correct Electrical Stickout (ESO)The electrical stickout (ESO) is the distance fromthe end of the contact tip to the end of the wire.

See Figure B.19.

Once the arc has been established, maintainingthe correct ESO becomes extremely important.The ESO should be approximately 3/8 to 1/2 inch(10 to 12 mm) long.

FIGURE B.20

FIGURE B.18

WARNINGFIGURE B.19

3/8 – 1/2” (10 – 12 mm)Electrical Stickout (ESO)

Contact Tip

Wire Electrode

Solidifying ridge

Molten puddle

The easiest way to tell whether the ESO is the cor-rect length is by listening to its sound. The correctESO has a distinctive “crackling” sound, very muchlike eggs frying in a pan. A long ESO has a hollow,blowing or hissing sound. If the ESO is too short,you may stick the contact tip or nozzle to the weldpuddle and/or fuse the wire to the contact tip.

4. The Correct Welding SpeedThe important thing to watch while welding is thepuddle of molten metal right behind the arc. SeeFigure B.20. Do not watch the arc itself. It is theappearance of the puddle and the ridge where themolten puddle solidifies that indicates correct weld-ing speed. The ridge should be approximately 3/8”(10 mm) behind the wire electrode.

Most beginners tend to weld too fast, resulting in athin uneven, “wormy” looking bead. They are notwatching the molten metal.

B-14

SP-125 PLUS

B-14 LEARNING TO WELD

Mild Steel 16 gauge or 1/16 inch(1.6 mm)

Electrode 0.035" (0.9 mm)NR-211-MP

Innershield Wire

Voltage Setting “V” B

Wire Feed Speed “o|o” 2

For the SP-175 Plus , use the following:Helpful Hints

1. For general welding, it is not necessary to weavethe arc, neither forward or backward nor sideways.Weld along at a steady pace. You will find it easier.

2. When welding on thin plate, you will find that youwill have to increase the welding speed, whereaswhen welding on heavy plate, it is necessary to gomore slowly in order to get good penetration.

3. When welding sheet metal 16 gauge (1.5 mm) andlighter, heat buildup may cause part warpage andburn through. One way to eliminate these problemsis to use the back-stepping method illustrated inFigure B.21.

FIGURE B.21

Practice

The best way of getting practice in the four skills thatenable you to maintain:

1. Correct welding position

2. Correct way to strike an arc

3. Correct electrical stickout

4. Correct welding speed

is to perform the following exercise.

Refer to Figure B.22.

1. Learn to strike an arc by positioning the gun overthe joint and touching the wire to the work.

2. Position face shield to protect face and eyes.

3. Depress gun trigger, hold gun so contact tip towork distance is about 3/8 to 1/2 inch (10 to 12mm) and the gun is at proper angle.

4. After you strike the arc, practice the correct electri-cal stickout. Learn to distinguish it by its sound.

5. When you are sure that you can hold the correctelectrical stickout, with a smooth “crackling” arcstart moving. Look at the molten puddle constantly,and look at the “ridge” where the metal solidifies.

6. Run beads on a flat plate. Run them parallel to thetop edge (the edge farthest away from you). Thisgives you practice in running straight welds, andalso gives you an easy way to check yourprogress. The 10th weld will look considerably bet-ter than the first weld. By constantly checking onyour mistakes and your progress, welding will soonbe a matter of routine.

First weld from A to B; then from C to A; thenfrom D to C; then from E to D, and so on.

B A C D E

Back-Stepping

FIGURE B.22

ContactTip

Gun Angle

ESO

B-15

SP-175 PLUS

B-15 LEARNING TO WELDMACHINE SET UP FOR THE GMAW (MIG)PROCESS

1. See PROCESS GUIDELINES in the OPERATIONsection for selection of welding wire and shieldinggas, and for range of metal thicknesses that can bewelded.

2. See the Application Guide on the inside of wirefeed section door for information on setting thecontrols.

3. Set the “Voltage” and “Wire Speed” controls to thesettings suggested on the Application Guide for thewelding wire and base metal thickness being used.The voltage control is marked “V” and the wire feedspeed is marked ʻʼolo.ʼʼ

4. Check that the polarity is correct for the weldingwire being used. Set the polarity for DC(+) whenwelding with the GMAW (MIG) process. See WorkCable Installation in the INSTALLATION section forinstructions for changing polarity.

5. Check that the gas nozzle and proper size linerand contact tip are being used and that the gassupply is turned on. If adjustable, set for 15 to 20cubic feet per hour (7 to 10 l/min.) under normalconditions, increase to as high as 35 CFH (17I/min.) under drafty (slightly windy) conditions.

6. Connect work clamp to metal to be welded. Workclamp must make good electrical contact to thework piece. The work piece must also be groundedas stated in the “Arc Welding Safety Precautions”at the beginning of this manual.

WELDING TECHNIQUES FOR THE GMAW(MIG) PROCESS

Four simple manipulations are of prime importancewhen welding. With complete mastery of the four,welding will be easy. They are as follows:

1. The Correct Welding PositionFigure B.23 illustrates the correct welding positionfor right handed people. (For left handed people, itis the opposite.)

When GMAW (MIG) welding on sheet metal, it isimportant to use the “forehand” push technique.

Hold the gun (of the gun and cable assembly) inyour right hand and hold the shield with your lefthand. (Left handers simply do the opposite.)

FIGURE B.23

When using the GMAW process on light gauge mater-ial, weld from right to left (if you are right handed).This results in a colder weld and has less tendency forburn through.

2. The Correct Way To Strike An Arc

ARC RAYS can burn eyes and skin.

When using an open arc process, itIs necessary to use correct eye,head and body protection.

Protect yourself and others, read“ARC RAYS can burn” at the frontof this manual.

1. Be sure the work clamp makes good electrical con-tact to the work.

2. Position gun over joint. End of wire may be lightlytouching the work.

3. Position face shield to protect face and eyes, closegun trigger, and begin welding. Hold the gun sothat the contact tip to work distance is about 3/8 to1/2 inch (10 – 12 mm).

4. To stop welding, release the gun trigger and pullthe gun away from the work after the arc goes out.

5. A ball may form at the tip end of the wire afterwelding. For easier restrikes, the ball may beremoved by feeding out a few inches of wire andcutting off the end of the wire with wire cutters.

6. When no more welding is to be done, close thevalve on the gas cylinder, momentarily operate thegun trigger to release gas pressure, then turn offthe machine.

WARNING

Helpful Hints

1. For general welding, it is not necessary to weavethe arc, neither forward or backward nor sideways.Weld along at a steady pace. You will find it easier.

2. When welding on thin plate, you will find that youwill have to increase the welding speed, whereaswhen welding on heavy plate, it is necessary to gomore slowly in order to get good penetration.

3. When welding sheet metal 16 gauge (1.5 mm) andlighter, heat buildup may cause part warpage andburn through. One way to eliminate these problemsis to use the back-stepping method illustrated inFigure B.21.

Practice

The best way of getting practice in the four skills thatenable you to maintain:

1. Correct welding position

2. Correct way to strike an arc

3. Correct electrical stickout

4. Correct welding speed

is to perform the following exercise.

Refer to Figure B.22.

1. Learn to strike an arc by positioning the gun overthe joint and touching the wire to the work.

2. Position face shield to protect face and eyes.

3. Depress gun trigger, hold gun so contact tip towork distance Is about 3/8 to 1/2 inch (10 to 12mm) and the gun is at proper angle.

B-16

SP-175 PLUS

B-16 LEARNING TO WELD

Mild Steel 16 gauge or 1/16 inch(1.6 mm)

Electrode Lincolnweld 0.030 L-56electrode

CO2 or 75/25% Ag/CO2

Voltage Setting “V” E

Wire Feed Speed “o|o” 5

For the SP-175 Plus , use the following:

FIGURE B.24

3. The Correct Electrical Stickout (ESO)The electrical stickout (ESO) is the distance fromthe end of the contact tip to the end of the wire.See Figure B.24.

Once the arc has been established, maintainingthe correct ESO becomes extremely important.The ESO should be approximately 3/8 to 1/2 inch(10 to 12 mm) long.

The easiest way to tell whether the ESO is the cor-rect length is by listening to its sound. The correctESO has a distinctive “crackling” sound, very muchlike eggs frying in a pan. A long ESO has a hollow,blowing or hissing sound. If the ESO is too short,you may stick the contact tip or nozzle to the weldpuddle and/or fuse the wire to the contact tip.

4. The Correct Welding SpeedThe important thing to watch while welding is thepuddle of molten metal right behind the arc. SeeFigure B.25. Do not watch the arc itself. It is theappearance of the puddle and the ridge where themolten Puddle solidifies that indicates correct weld-ing speed. The ridge should be approximately 3/8”(10 mm) behind the wire electrode.

Most beginners tend to weld too fast, resulting in athin, uneven, “wormy” looking bead. They are notwatching the molten metal.

FIGURE B.25

Contact Tip

Wire Electrode

ESO

Molten puddle

Base metalWeld metal ridge

B-17 B-17LEARNING TO WELD4. After you strike the arc, practice the correct electri-

cal stickout. Learn to distinguish it by its sound.

5. When you are sure that you can hold the correctelectrical stickout, with a smooth “crackling” arc,start moving. Look at the molten puddle constantly.

6. Run beads on a flat plate. Run them parallel to thetop edge (the edge farthest away from you). Thisgives you practice in running straight welds, andalso gives you an easy way to check yourprogress. The 10th weld will look considerably bet-ter than the first weld. By constantly checking onyour mistakes and your progress, welding will soonbe a matter of routine.

TROUBLESHOOTING WELDSGood welds have excellent appearance.

To Eliminate Porosity (in order of importance):

1. Turn on gas supply, if used

2. Decrease voltage.

3. Increase stickout.

4. Increase WFS (wire feed speed).

5. Decrease drag angle.

6. Decrease travel speed.

NOTE: Always be sure the joint is free from moisture,oil, rust, paint or other contaminants.

To Eliminate a Ropy Convex Bead(in order of importance):

1. Increase voltage

2. Decrease stickout.

3. Decrease WFS (wire feed speed.

4. Decrease travel speed.

5. Decrease drag angle.

6. Check for correct gas, if used.

To Reduce Spatter (in order of importance):

1. Increase voltage.

2. Increase drag angle.

3. Decrease stickout.

4. Increase WFS (wire feed speed).

5. Decrease travel speed.

6. Check for correct gas, if used.

To Correct Poor Penetration (in order of impor-tance):

1. Decrease stickout.

2. Decrease WFS (wire feed speed).

3. Increase voltage.

4. Decrease speed.

5. Decrease drag angle.

6. Check for correct gas, if used.

If Arc Blow Occurs (in order of importance):

NOTE: Try different ground connection locationsbefore adjusting procedures.

1. Decrease drag angle.

2. Increase stickout.

3. Decrease voltage.

4. Decrease WFS (wire feed speed.

5. Decrease travel speed.

To Eliminate Stubbing* (in order of importance):

1. Increase voltage

2. Decrease WFS (wire feed speed)

3. Decrease stickout

4. Increase drag angle

* Stubbing occurs when the electrode drives throughthe molten puddle and hits the bottom plate tendingto push the gun up.

SP-175 PLUS

B-18

SP-125 PLUS

B-18 LEARNING TO WELDProper Gun Handling

Most feeding problems are caused by improper han-dling of the gun cable or electrodes.

1. Do not kink or pull the gun around sharp corners

2. Keep the gun cable as straight as practical whenwelding.

3. Do not allow dolly wheels or trucks to run over thecables.

4. Keep the cable clean.

5. Innershield electrode has proper surface lubrica-tion. Use only clean, rust-free electrode.

6. Replace contact tip when it becomes worn or theend is fused or deformed.

B-19 B-19 APPLICATION CHART

SP-175 PLUS

C-1 C-1

SP-175 PLUS

ACCESSORIES6. K695-2 Spot / Stitch Timer Kit — Includes spot

timer to control the spot welding arc time, and astitch timer to control the on/off cycle time of thearc to prevent burnthrough on thin gauge metals.Also includes spot welding nozzle.

The Spot/Stitch Timer Kit installs inside the wirefeed compartment, replacing the blank panel locat-ed below the gun trigger lead connectors, per theinstallation instructions included with the kit.

7. K549-1 .035 (0.9 mm) Innershield Welding KitIncludes a contact tip, a gasless nozzle and acable liner to permit the Magnum™ 100L gun andcable to use .035” (0.9 mm) diameter flux-coredelectrode. Also included is a spool of .035 (0.9mm) Innershield NR-211-MP.

OPTIONAL ACCESSORIES

1. K520 Utility Cart — Designed to transport theLincoln family of small welders. Has provisions formounting a single gas cylinder. Has front castersand large rear wheels. Handle height is easilyadjustable. Bottom tray provided for tools andaccessories. Easy assembly required; takes lessthan 15 minutes.

2. K1800-1 CO2 Adjustable Regulator and Hose Kit —Includes an adjustable pressure flow regulator foruse on CO2 cylinders. Weld shielding gas may be obtained from a weld-ing supply distributor.

Also included is a gas hose which connects to therear of the welder.

See “Gas Connection” in Installation section forinstallation instructions.

3. K1799-1 Argon-Mixed Gas AdjustableRegulator and Hose Kit (1)

Includes an adjustable pressure and flow regulatorfor use on argon-mixed gas cylinders. Also includ-ed is a gas hose which connects to the rear of thewelder.

4. K586-1 Deluxe Adjustable Gas Regulator &Hose KitAccommodates CO2 or mixed Gas Cylinders.

5. K663-2 Aluminum Welding Kit — This kitrequired for welding with .035” aluminum wire.Included with this kit are a drive roll and idle rollassembly, liner and guide tubes and a contact tip.It is important when changing between weldingwith steel wire and aluminum to exchangethese components due to the lubricant appliedto steel wire. Failure to do so may result in con-taminated welds when welding aluminum.

See Maintenance section for instructions on installingdrive roll, cable liner, contact tip and their proper con-figuration.

C-2 C-2 ACCESSORIESINNERSHIELD (FCAW)CONVERSION

Several changes are needed to convert the unit foroperation with the Innershield (FCAW) process. TheInnershield Kits include all the necessary accessoriesfor this conversion and are provided for this purpose.The following conversions should be made using thecontents of a kit:

1. Change the output polarity to DC(-). See “WorkCable Installation” section for details.

2. Install proper drive roll for the wire size selected.See “Changing Drive Roll” in Maintenance sectionfor details.

3. Install the proper gun liner and tip for the wire sizeselected. See “Component Replacement” inMaintenance section for details.

4. Remove gas nozzle (if installed) and install gaslessnozzle. To remove, simply unscrew.

REPLACEMENT PARTS

Complete Gun and Cable AssemblyL8311-6

Contact Tip .025” (0.6 mm)S19726-1

Contact Tip .030” (0.8 mm)S19726-2

Contact Tip .035” (0.9 mm)S19726-3

Contact Tip .045” (1.2 mm)S19726-4

Contact Tip-Tapered .025” (0.6 mm)S20278-1

Contact Tip-Tapered .030” (0.8 mm)S20278-2

Contact Tip-Tapered .035” (0.9 mm)S20278-3

Contact Tip-Tapered .045” (1.2mm)S20278-4

Contact Tip .035A” (0.9 mm)S24221-1 (Aluminum Tip)

Liner .023 - .030” (0.6 - 0.8 mm)M16291-2

Liner .030 - .035” (0.8 - 0.9 mm)M16291-5

Liner .035/.045” (0.9/1.2 mm)M16291-1

Liner - Nylon .035/.045” (0.9/1.2 mm)M18971-1 (Aluminum Feed)

Gas DiffuserS19728

Gas NozzleM16294

Gas Nozzle-Tip Recessed 3/8” (9.5 mm) Opening I.D.M16684

Gas Nozzle-Tip Recessed 1/2” (12.7 mm) Opening I.D.M16684-1

Gas Nozzle-Tip Recessed 5/8” (15.9 mm) Opening I.D.M16684-2

Spot Welding NozzleM17846-1

Gasless Nozzle (Innershield Only)M16418

SP-175 PLUS

MAINTENANCE

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Disconnect input power by remov-ing plug from receptacle beforeworking inside SP-175 Plus . Useonly grounded receptacle. Do nottouch electrically “hot” partsinside SP-175 Plus .

• Have qualified personnel do themaintenance and trouble shootingwork.

ITEMS REQUIRING NO MAINTENANCE

• Drive Motor and Gearbox – Lifetime lubrication• Fan Motor- Lifetime lubrication.• Wire Reel Spindle – Do NOT lubricate shaft.

ROUTINE AND PERIODIC MAINTE-NANCE

BEFORE EACH USE• Check over machine and accessories for any obvious

condition that may prevent safe performance or oper-ation, repair or replace items as necessary to correctany abnormal condition.

AFTER 5 MINUTES OF WELDING or when spatter accumulates in nozzle

• Clean nozzle to avoid bridging between nozzle andcontact tip which results in shorted nozzle, poor weldsand overheated gun. Hint: Anti-stick spray or gelavailable from a welding supply distributor mayreduce buildup and aid in spatter removal.

AFTER EACH SPOOL OF WIRE FEED

• Remove contact tip and clean inside diameter withshort piece of wire

• Clean cable liner – when rough and erratic wire feed-ing occur.

MAINTENANCED-1 D-1

WARNING

AFTER FEEDING 50# OF FLUX COREDWIRE OR 300# OF SOLID WIRE

• Unplug machine or turn power switch to OFF – “O”position. Remove gun and cable from machine.

• Remove gas nozzle and contact tip from gun.

• Lay cable out straight - blow out gently into gun endwith compressed air. Bend cable back and forth –blow out again – Repeat until clean.

Excessive pressure at start may cause the dirt toform a plug.

PERIODICALLY AS REQUIRED

• Blow dirt out of the welder with low pressure air toeliminate excessive dirt and dust buildup that couldcause welder to run hot.

• Blow dirt out of: Rectifier & Fan Motor Assembly;PC Board located on Case Side Assembly; andCenter Assembly components.

• Vacuum accumulated dirt from gearbox and wirefeed section.

• Inspect the incoming guide tube and clean insidediameter if necessary. Replace when excessivelyworn.

• Replace Contact Tip – when hole is enlarged orelongated (refer to “CHANGING THE CONTACTTIP”, in this section).

• Replace gas nozzle.

• Replace Liner – when wire feeding problems occurand other items have been checked (refer to“CHANGING LINER” procedure in this section).

• Replace internal gun handle parts as necessary(see Procedure at the end of this section).

WARNING

SP-175 PLUS

D-2

SP-175 PLUS

D-2 MAINTENANCE

GUN AND CABLE MAINTENANCE

FOR MAGNUM™ 100L GUN

Gun Cable CleaningClean cable liner after using approximately 300 lbs(136 kg) of solid wire or 50 lbs (23 kg) of flux-coredwire. Remove the cable from the wire feeder and lay itout straight on the floor. Remove the contact tip fromthe gun. Using low pressure air, gently blow out thecable liner from the gas diffuser end.

Excessive pressure at the start may cause the dirtto form a plug.

Flex the cable over its entire length and again blowout the cable. Repeat this procedure until no furtherdirt comes out.

Contact Tips, Nozzles, and Gun Tubes1. Dirt can accumulate in the contact tip hole and

restrict wire feeding. After each spool of wire isused, remove the contact tip and clean it by push-ing a short piece of wire through the tip repeatedly.Use the wire as a reamer to remove dirt that maybe adhering to the wall of the hole through the tip.

2. Replace worn contact tips as required. A variableor “hunting” arc is a typical symptom of a worn con-tact tip. To install a new tip, choose the correct sizecontact tip for the electrode being used (wire size isstenciled on the side of the contact tip) and screw itsnugly into the gas diffuser.

3. Remove spatter from inside of gas nozzle and fromtip after each 10 minutes of arc time or as required.

4. Be sure the gas nozzle is fully screwed onto thediffuser for gas shielded processes. For theInnershield® process, the gasless nozzle shouldbe screwed onto the diffuser.

5. To remove gun tube from gun, remove gas nozzleor gasless nozzle and remove diffuser from guntube. Remove both collars from each end of thegun handle and separate the handle halves.Loosen the locking nut holding the gun tube inplace against the gun end cable connector.Unscrew gun tube from cable connector. To installgun tube, screw the locking nut on the gun tube asfar as possible. Then screw the gun tube into thecable connector until it bottoms. Then unscrew (nomore than one turn) the gun tube until its axis isperpendicular to the flat sides of the cable connec-tor and pointed in the direction of the trigger.Tighten the locking nut so as to maintain the properrelationship between the gun tube and the cableconnector. Replace the gun handle, trigger and dif-fuser. Replace the gas nozzle or gasless nozzle.

CAUTION

CONFIGURATION OF COMPONENTS IN WIRE FEEDING SYSTEMContact Tip Cable Liner Drive Roll

Components shipped with S19726-1(In Gun) M16291-5 M15448SP-175 Plus .025” (0.6mm) .030-.035” 2 Smooth grooves

S19726-2&-3(Loose) (0.8-0.9 mm) Small .023-.025” (Stenciled .025).030” & .035” Large .030-.035” (Stenciled .030-.035)

K549-1 .035” (0.9mm) S19726-3 M16291-6 Use Large groove Innershield Welding Kit .035” (0.9mm) .035” (0.9mm) KP666-035

K549-4 .045 (1.2 mm) S19726-4 M16291-1 M15448-2 .035/.045”Innershield Welding Kit .045” (1.2mm) .045” (1.2mm) Dual groove both sides

K663-2 .035” S24221-1 M18971-1 S24220 .035-3/64” (drive rollAluminum or Stainless Kit*• .035A” (0.9mm) .045” (1.2mm) S24219 (idle roll)

KP666-035C M15448-12 Knurled grooves for .035” (0.9mm)

• If .030 Solid wire feeding is desired obtain an S19726-2 Contact Tip, an M16291-2 Cable Liner and an M15448 Drive Roll (Smaller Groove).

* It is important when changing between welding with steel wire and aluminum to exchange feeding components due to the lubricant applied to steel wire. Failureto do so may result in contaminated welds when welding aluminum.

D-3 D-3 MAINTENANCECOMPONENT REPLACEMENT PROCEDURES

CHANGING THE CONTACT TIP

1. Unplug or turn power switch to Off “O” position.

2. Refer to Figure D.2. Remove the gas nozzle fromthe gun by unscrewing counter-clockwise.

3. Remove the existing contact tip from the gun byunscrewing counter-clockwise.

4. Insert and hand tighten desired contact tip.

5. Replace gas nozzle.

CHANGING THE SP-175 Plus FOR USEWITH INNERSHIELD FLUX CORED WIRE

• Change The Contact Tip• Acquire Innershield Welding Kit (See ACCES-

SORIES section). Note: Feeding .035” Innershieldrequires nothing extra but feeding will be optimizedwith the use of the KP666-035C drive roll.

1. Refer to Figure D.2. Remove the gas nozzle fromthe gun by unscrewing counter-clockwise.

2. Remove the existing contact tip from the gun byunscrewing counter-clockwise.

3. Insert and hand tighten the contact tip for use with.035” or .045” (.045” requires a liner change also)Innershield Flux Cored Wire.

4. Replace gas nozzle – The gasless nozzle may beused instead of the gas nozzle to give improvedvisibility of the arc.

CHANGING DRIVE ROLL

The drive roll, Figure D.1 Item 1, has two grooves; onefor .023" – .025" (0.6mm) solid steel electrode and a larg-er groove for .030" (0.8mm) solid and .035" (0.9mm) flux-cored steel electrode. As shipped, the drive roll isinstalled in the .023" – .025" (0.6mm) position.

If .030"-.035" (0.9mm) wire is to be used, the drive rollmust be reversed as follows:

1. Turn the power switch to OFF (marked “O”).

2. Release the spring-loaded idle arm tensioner, Figure D.1Item 2, and lift the idle roll arm, Figure D.1 Item 3, awayfrom the drive roll.

3. Loosen the Phillips Head screw holding the driveroll onto the drive shaft.

When inching the welding wire, the drive rolls,gun connector block, and gun contact tip areenergized relative to work and ground and remainenergized for several seconds after the gun trig-ger is released.

4. Remove the drive roll, flip over and reinstall with theopposite groove closest to the gearbox.

NOTE: The stencil of the groove that you want to useis marked on the outside of the drive roll(when installed)

5. Push a length of straightened welding wire throughthe wire feeder guide tubes and reset the PhillipsHead screw to secure the drive roll onto the shaft.

6. Reapply the spring loaded idle arm tensioner.

7. Turn the power “ON” (I) and check the drive roll forslipping when feeding wire. DO NOT OVERTIGHTEN - Ifnecessary, tighten or loosen the spring loaded idle arm tension-er (2).

FIGURE D.1

CAUTION

3

2

1

SP-175 PLUS

D-4

SP-175 PLUS

D-4MAINTENANCECHANGING LINER

NOTICE: The variation in cable lengths prevents theinterchangeability of liners. Once a liner has beencut for a particular gun, it should not be installed inanother gun unless it can meet the liner cutofflength requirement. Refer to Figure D.2.

1. Remove gun and cable assembly from machine.

2. Remove the gas nozzle from the gun byunscrewing counter-clockwise.

3. Remove the existing contact tip from the gun byunscrewing counter-clockwise.

4. Remove the gas diffuser from the gun tube byunscrewing counter-clockwise.

5. Lay the gun and cable out straight on a flat sur-face. Loosen the set screw located in the brassconnector at the wire feeder end of the cable.Pull the liner out of the cable.

6. Insert a new untrimmed liner into the connectorend of the cable. Be sure the liner bushing isstenciled appropriately for the wire size beingused.

7. Fully seat the liner bushing into the connector.Tighten the set screw on the brass cable con-nector. At this time, the gas diffuser should notbe installed onto the end of the gun tube.

8. With the gas nozzle and diffuser removed fromthe gun tube, be sure the cable is straight, andthen trim the liner to the length shown in theFigure D.2. Remove any burrs from the end ofthe liner.

9. Screw the gas diffuser onto the end of the guntube and securely tighten.

10. Replace the contact tip and nozzle.

1-1/4 (31.8 mm)Liner Trim Length

Gas Diffuser

Gas Nozzle orGasless NozzleSet Screw Brass Cable

Connector

Liner Assembly (Liner bushing to be sealed tightagainst brass cable connector)

FIGURE D.2Liner trim length

D-5

SP-125 PLUS

D-5 MAINTENANCEGUN HANDLE PARTS

The gun handle consists of two halves that are heldtogether with a collar on each end. To open up thehandle, turn the collars approximately 60 degreescounter-clockwise until the collar reaches a stop. Thenpull the collar off the gun handle. If the collars are diffi-cult to turn, position the gun handle against a corner,place a screwdriver against the tab on the collar andgive the screwdriver a sharp blow to turn the collarpast an internal locking rib. See Figure D-3.

FIGURE D.3➣

Counter-clockwise

E-1

SP-175 PLUS

E-1 TROUBLESHOOTING

If for any reason you do not understand the test procedures or are unable to Performthe tests/repairs safely, contact your LOCAL AUTHORIZED LINCOLN ELECTRICFIELD SERVICE FACILITY for assistance before you proceed.___________________________________________________________________

If machine case sides and top are removed, the case front must be supported.Failure to do this could result in mechanical or electrical damage to the SP-175 Plus.___________________________________________________________________

CAUTION

CAUTION

This Troubleshooting Guide is provided to help youlocate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.

Step 1. LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptomsthat the machine may exhibit. Find the listing thatbest describes the symptom that the machine isexhibiting.

Step 2. POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” liststhe obvious external possibilities that may contributeto the machine symptom.

Step 3. RECOMMENDED COURSE OF ACTIONThis column provides a course of action for thePossible Cause, generally it states to contact yourlocal Lincoln Authorized Field Service Facility.

If you do not understand or are unable to perform theRecommended Course of Action safely, contact yourlocal Lincoln Authorized Field Service Facility.

HOW TO USE TROUBLESHOOTING GUIDE

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician andmachine operator and will invalidate your factory warranty. For your safety and to avoid ElectricalShock, please observe all safety notes and precautions detailed throughout this manual.

__________________________________________________________________________

WARNING

E-2

SP-175 PLUS

E-2 TROUBLESHOOTING

PROBLEMS(SYMPTOMS)

Major physical or electrical damageis evident.

No wire feed, weld output or gasflow when gun trigger is pulled. Fandoes NOT operate.

No weld output or wire feed whengun trigger is pulled. Fan runs andgas flows normally.

No weld output when gun trigger ispulled. Fan runs, gas flows andwire feeds normally.

No Wire feed, weld output or gasflow when the gun trigger is pulled -Fan operates normally.

POSSIBLE AREAS OFMISADJUSTMENT(S)

Contact your LOCAL LINCOLNAUTHORIZED FIELD SERVICEFACILITY.

1. Make sure correct voltage isapplied to the machine (208 or230 VAC 60 Hz.).

2. Make certain that power switchis in the ON position.

Contact your LOCAL LINCOLNAUTHORIZED FIELD SERVICEFACILITY.

1. Arc voltage may be set too low.

2. Gun tip may be worn – Replace.

3. Check for correct input voltageto machine.

4. Gun or work cable may befaulty.

1. Check the circuit breaker locat-ed in the machineʼs wire drivecompartment. Reset if tripped.

2. The thermostat may be trippeddue to overheating. Let machinecool. Weld within the duty cycleor remove any air obstruction tomachine.

3. Wire feed motor may be over-loaded. Correct feeding prob-lem. (Check brake adjustment-could be to tight)

4. Gun trigger may be faulty.

RECOMMENDEDCOURSE OF ACTION

Contact your local LincolnAuthorized Field Service Facility.

OUTPUT PROBLEMS

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact yourLOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

Observe Safety Guidelines detailed in the beginning of this manual.

E-3

SP-175 PLUS

E-3TROUBLESHOOTING

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact yourLOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

No wire feed when gun trigger ispulled. Fan runs, gas flows andmachine has correct open circuitvoltage (33 VDC maximum) – weldoutput.

Wire feed speed motor runs veryfast. Weld output, gas flow and fanoperate normally.

POSSIBLE AREAS OFMISADJUSTMENT(S)

1. If the wire drive motor is runningcheck to see if the correct wireis in the machine.

2. If the wire drive motor is runningmake sure that the correct driverolls are installed in themachine.

3. Check for clogged cable liner orfeeding problems.

4. Check brake adjustment (couldbe too tight).

1. Make sure that the wire speedcontrol is not set at maximum.

RECOMMENDEDCOURSE OF ACTION

Contact your local LincolnAuthorized Field Service Facility.

FEEDING PROBLEMS

PROBLEMS(SYMPTOMS)

Low or no gas flow when guntrigger is pulled. Wire feed, weldoutput and fan operate normally.

POSSIBLE AREAS OFMISADJUSTMENT(S)

1. Check gas supply, flow regulatorand gas hoses.

2. Check gun connection tomachine for obstruction or leakyseals.

RECOMMENDEDCOURSE OF ACTION

Contact your local LincolnAuthorized Field Service Facility.

GAS FLOW PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

E-4

SP-125 PLUS

E-4 TROUBLESHOOTINGObserve Safety Guidelines detailed in the beginning of this manual.

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact yourLOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

Arc is unstable – Poor starting

POSSIBLE AREAS OFMISADJUSTMENT(S)

1. Check for correct input voltageto machine – 208 or 230 VAC.

2. Check for proper electrodepolarity for process.

3. Check gun tip for wear or dam-age – Replace.

4. Check for proper gas and flowrate for process.

5. Check work cable for loose orfaulty connections.

6. Check gun for damage orbreaks.

7. Check wire feed to assuresmooth wire feeding (checkbrake adjustment).

RECOMMENDEDCOURSE OF ACTION

Contact your local LincolnAuthorized Field Service Facility.

WELDING PROBLEMS

F-1

SP-175 PLUS

F-1 WIRING DIAGRAMS

M19

060

L1L2

31

H2

202

201

D5

D7D2

D8

204

204

203

203

203

204

-+O

UTP

UT

CH

OK

E

TO WO

RK

ELEC

TRIC

AL S

YMB

OLS

PER

E15

37

CIR

CU

ITB

REA

KER

31A

12

3

45

6

LATC

H

FAN

MO

TOR

12

34

LATC

H

5

67

89

10

J1J2

CAV

ITY

NU

MB

ERIN

G S

EQU

ENC

E

12

34

56

12

34

56

78

910

7 32A

CO

NTR

OL

P.C

. BO

ARD

539

541

207

205

206

541

539

203

204

210

209

213

208

211

T1

WIR

E FE

ED M

OTO

R

213A

GU

N T

RIG

GER

THER

MO

STAT

(MO

UNTE

D TO

DIO

DE H

EATS

INK)

+

208

209

210

5KW

IRE

SPEE

D

205

206

207

5K

( J1

)

( J2

)

*

**CO

NN

ECTO

R C

AVIT

Y N

UM

BER

ARC

VOLT

AGE

R1 R2

7 32A

N.A

.

N.C

.

N.C

.N

.D.

24 V

ACAU

X W

DG

.

NOTE

S:

N.C.

CO

MPO

NENT

VIE

WED

FRO

M R

EAR.

HIG

H V

OLT

AG

Eca

n ki

ll

Only

quali

fied

pers

ons

shou

ld in

stall

, use

or

serv

ice th

is m

achin

e.

Do n

ot o

pera

te w

ith c

over

s re

mov

ed.

Do n

ot to

uch

elect

ricall

y live

par

ts

Disc

onne

ct in

put p

ower

by u

nplug

ging

powe

r cor

d be

fore

ser

vicing

WHI

CH IS

CLO

SEST

TO

THE

CEN

TER

PANE

L.

N.B

., N

.D.

(CO

MPO

NEN

T SI

DE

OF

BO

ARD

)N.

D. B

OLT

ED A

LUM

INUM

CO

NNEC

TIO

NS R

EQUI

RE T

1283

7 JO

INT

COM

POUN

D (D

OW

CO

RNIN

G 3

40) W

HEN

REAT

TACH

ING

.

SP

-175

Plu

s W

IRIN

G D

IAG

RA

M C

OD

E 10

542

12

34

5

LATC

HJ3

54

32

1

JUM

PERE

D PL

UG S

TAND

ARD

SPO

T/ST

ITCH

TIM

ER O

PTIO

NAL

215

215

213

( J3

)*

203

203

D4

D6

D1

204

204

C1

N.D

.+

THER

MO

STAT

(MO

UNTE

D TO

SEC.

CO

IL)

31A

32H

1

H1

(230

V)

208/

230

60H

zG

ASSO

LEN

OID

H1

H3

G

C

AS

EG

RO

UN

DIN

G

STU

D

TO E

ARTH

GRO

UND

PER

NATI

ONA

L,LO

CAL

OR

OTH

ERAP

PLIC

ABLE

ELEC

TRIC

ALCO

DES.

H3

(208

V)

N.A.

DIO

DES

D1, D

3, D

5 &

D7 A

RE M

OUN

TED

ON

THE

OUT

SIDE

HEA

TSIN

K.N.

B. D

IODE

S D2

, D4,

D6

& D8

ARE

MO

UNTE

D O

N TH

E IN

SIDE

HEA

TSIN

K,

CU

STO

MER

VO

LTA

GE

REC

ON

NEC

TIO

N F

OR

DU

AL

VOLT

AG

E M

AC

HIN

EM

ACHI

NES

ARE

SHIP

PED

FRO

M F

ACTO

RY C

ONN

ECTE

D FO

R 23

0V A

S SH

OW

N. T

O C

ONN

ECT

WEL

DER

FOR

REVE

RSE

OF

ABO

VE P

ROCE

DURE

. SEE

INST

RUCT

ION

MAN

UAL

FOR

DETA

ILS.

SLEE

VING

, REI

NSTA

LL C

ASE

SIDE

BEF

ORE

CO

NNEC

TING

INPU

T PO

WER

. RE

CONN

ECTI

ON

TO 2

30V

IS

D3

ON

-OFF

SWIT

CH

S1

FRO

M T

AB T

ERM

INAL

H1.

REM

OVE

TAP

E SE

CURI

NG H

3 TO

LEA

D SL

EEVI

NG A

ND C

ONN

ECT

H3 T

O T

ABTE

RMIN

AL H

1. IN

SULA

TE U

NUSE

D H1

LEA

D FO

R 30

0V W

ITH

ELEC

TRIC

AL T

APE

AND

SECU

RE T

O L

EAD

208V

INPU

T. D

ISCO

NNEC

T W

ELDE

R FR

OM

INPU

T PO

WER

, REM

OVE

CAS

E SI

DE, R

EMO

VE L

EAD

MAR

KED

H1

GU

N C

ABLE

CO

ND

UC

TOR

BLO

CK

120,

000

f50

V

.004

7 f

3KV

.004

7 f

3KV

C

AS

EG

RO

UN

DIN

G

STU

D

RF

CH

OK

EAS

'BLY

4-16

-99G

NO

TE

: Thi

s di

agra

m is

for

refe

renc

e on

ly. I

t may

not

be

accu

rate

for

all m

achi

nes

cove

red

by th

is m

anua

l. T

hesp

ecifi

c di

agra

m fo

r a

part

icul

ar c

ode

is p

aste

d in

side

the

mac

hine

on

one

of th

e en

clos

ure

pane

ls.

NOTES

Now Available...12th EditionThe Procedure Handbook of Arc Welding

With over 500,000 copies of previous editions publishedsince 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry.

This printing wil l go fast so donʼt delay. Place your order now using the coupon below.

The hardbound book contains over 750 pages of weldinginformation, techniques and procedures. Much of this material has never been included in any other book.

A must for all welders, supervisors, engineers anddesigners. Many welding instructors will want to use the bookas a reference for all students by taking advantage of the lowquantity discount prices which include shipping by4th class parcel post.

$15.00 postage paid U.S.A. Mainland

How To Read Shop Drawings

The book contains the latest information and applicationdata on the American Welding Society Standard WeldingSymbols. Detailed discussion tells how engineers anddraftsmen use the “short-cut” language of symbols to passon assembly and welding information to shop personnel.

Practical exercises and examples develop the readerʼs abilityto visualize mechanically drawn objects as they will appearin their assembled form.

187 pages with more than 100 illustrations. Size 8-1/2” x 11”Durable, cloth-covered board binding.

$4.50 postage paid U.S.A. Mainland

New Lessons in Arc WeldingLessons, simply written, cover manipulatory techniques;

machine and electrode characteristics; related subjects,such as distortion; and supplemental information on arcwelding applications, speeds and costs. Practice materials,exercises, questions and answers are suggested for each lesson.

528 pages, well illustrated, 6” x 9” size, bound in simulated,gold embossed leather.

$5.00 postage paid U.S.A. Mainland

Need Welding Training?The Lincoln Electric Company operates the oldest and

most respected Arc Welding School in the United States at itscorporate headquarters in Cleveland, Ohio. Over 100,000 stu-dents have graduated. Tuit ion is low and the training is “hands on”

For details write: Lincoln Welding School22801 St. Clair Ave. Cleveland, Ohio 44117-1199.

and ask for bulletin ED-80 or call 216-383-2259 and ask for theWelding School Registrar.

Lincoln Welding SchoolBASIC COURSE $700.00

5 weeks of fundamentalsThere is a 10% discount on all orders of $50.00 or more for shipment at one time to one location.Orders of $50 or less before discount or orders outside of North America must be prepaid with charge, check or money order in U.S. Funds Only.Prices include shipment by 4 th Class Book Rate for U.S.A. Mainland Only. Please allow up to 4 weeks for delivery.UPS Shipping for North America Only. All prepaid orders that request UPS shipment please add:

$5.00 For order value up to $49.99$10.00 For order value between $50.00 & $99.99$15.00 For order value between $100.00 & $149.00

For North America invoiced orders over $50.00 & credit card orders, if UPS is requested, it will be invoiced or charged to you at cost.Outside U.S.A. Mainland order must be prepaid in U.S. Funds. Please add $2.00 per book for surface mail or $15.00 per book for air parcel post shipment.METHOD OF PAYMENT: (Sorry, No C.O.D. Orders)

CHECK ONE:Name: _______________________________________________

Please Invoice (only if order is over $50.00)Address: _______________________________________________

Check or Money Order Enclosed, U.S. Funds only _______________________________________________

Credit Card - Telephone: _______________________________________________

Signature as it appears on Charge Card:Account No. |_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_|_| Exp Date |_|_| |_|_| ______________________Month Year

USE THIS FORM TO ORDER: Order from: BOOK DIVISION, The Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199BOOKS OR FREE INFORMATIVE CATALOGS Telephone: 216-383-2211 or, for fastest service, FAX this completed form to: 216-361-5901.

Lincoln Welding School Titles: Price Code Quantity Cost(ED-80) New Lessons in Arc Welding $5.00 L

Seminar Information Procedure Handbook “Twelfth Edition” $15.00 PH(ED-45) How to Read Shop Drawings $4.50 H

Educational Video Information Incentive Management $5.00 IM(ED-93) A New Approach to Industrial Economics $5.00 NA

James F. Lincoln Arc Welding The American Century of John C. Lincoln $5.00 ACFoundation Book Information Welding Preheat Calculator $3.00 WC-8

(JFLF-515) Pipe Welding Charts $4.50 ED-89SUB TOTAL

Additional Shipping Costs if anyTOTAL COST

VISA ®MasterCardMasterCard

®

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BEUSED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOSCONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS AETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

● Do not touch electrically live parts orelectrode with skin or wet clothing.

● Insulate yourself from work andground.

● No toque las partes o los electrodosbajo carga con la piel o ropa moja-da.

● Aislese del trabajo y de la tierra.

● Ne laissez ni la peau ni des vête-ments mouillés entrer en contactavec des pièces sous tension.

● Isolez-vous du travail et de la terre.

● Berühren Sie keine stromführendenTeile oder Elektroden mit IhremKörper oder feuchter Kleidung!

● Isolieren Sie sich von denElektroden und dem Erdboden!

● Não toque partes elétricas e elec-trodos com a pele ou roupa molha-da.

● Isole-se da peça e terra.

● Keep flammable materials away.

● Mantenga el material combustiblefuera del área de trabajo.

● Gardez à l’écart de tout matérielinflammable.

● Entfernen Sie brennbarres Material!

● Mantenha inflamáveis bem guarda-dos.

● Wear eye, ear and body protection.

● Protéjase los ojos, los oídos y elcuerpo.

● Protégez vos yeux, vos oreilles etvotre corps.

● Tragen Sie Augen-, Ohren- und Kör-perschutz!

● Use proteção para a vista, ouvido ecorpo.

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.

● Keep your head out of fumes.● Use ventilation or exhaust to

remove fumes from breathing zone.

● Los humos fuera de la zona de res-piración.

● Mantenga la cabeza fuera de loshumos. Utilice ventilación oaspiración para gases.

● Gardez la tête à l’écart des fumées.● Utilisez un ventilateur ou un aspira-

teur pour ôter les fumées des zonesde travail.

● Vermeiden Sie das Einatmen vonSchweibrauch!

● Sorgen Sie für gute Be- undEntlüftung des Arbeitsplatzes!

● Mantenha seu rosto da fumaça.● Use ventilação e exhaustão para

remover fumo da zona respiratória.

● Turn power off before servicing.

● Desconectar el cable de ali-mentación de poder de la máquinaantes de iniciar cualquier servicio.

● Débranchez le courant avantl’entretien.

● Strom vor Wartungsarbeitenabschalten! (Netzstrom völlig öff-nen; Maschine anhalten!)

● Não opere com as tampas removidas.● Desligue a corrente antes de fazer

serviço.● Não toque as partes elétricas nuas.

● Do not operate with panel open orguards off.

● No operar con panel abierto oguardas quitadas.

● N’opérez pas avec les panneauxouverts ou avec les dispositifs deprotection enlevés.

● Anlage nie ohne Schutzgehäuseoder Innenschutzverkleidung inBetrieb setzen!

● Mantenha-se afastado das partesmoventes.

● Não opere com os paineis abertosou guardas removidas.

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •