imi flow design standard kits...imi flow design standard kits pre-configured automatic and manual...
TRANSCRIPT
![Page 1: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/1.jpg)
IMI Flow Design Standard Kits
Pre-configured Automatic and Manual Coil Hook-up Kits
![Page 2: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/2.jpg)
Standard Kit Ordering Instructions
NOTE: If ordering just (1) kit, add GPM, Venturi #, or "UB" to the end of the model #
If ordering multiple kits, include tagging schedule with tag #, SK size, and GPM, Venturi #, or "UB" (for shutoff kits) Only 2 reductions are allowed in body size. EX: an AC can be 1 ¼” on the ball valve end and ¾” on the union end
Step #1 Choose your base configuration
option Kit includes
1 Balancing device with dual PT ports and manual air vent and strainer with PT port and drain
2 Balancing device with dual PT ports, union with air vent and PT port, and strainer with PT port and drain
3 02 components + manual shutoff valve for bypass and T2 bypass adapter port in strainer (available in sizes 050, 075, 100)
3T 02 components + manual shutoff valve for bypass & tee (TE) from IMI FDI or others (available in sizes 125, 150, 200)
Step #2 Choose A for Automatic Balancing and M for Manual Balancing
Step #3 Choose A, B, C, or D
A Standard length accessories
B Extend all accessories
C Standard length accessories and add 2' hoses
D Extend all accessories and add 2' hoses
Step #4 Tell us the size and connection type for your kit components (from left to right in the drawing)
Coil What is the size of the coil connection (1-6)? What type of valve connection to the coil (F or S)?
ATC What is the size of the ATC (1-6)? What type of valve connection do you need (typically this is male - M)?
System What is the size of the system connection (1-6)? What type of valve connection to the system do you need (F or S)?
Sizes See example below but 1 = 050, 2 = 075, 3 = 100, 4 = 125, 5 = 150, & 6 = 200
Types F = female, S = sweat, & M = male
Model # Builder
SK 1 A A Coil ATC System Additions / Exchanges GPM & H/L; V # or UB
1 A A EX: 2F EX: 1M EX: 2F EX: XUP (extra union) Ex: 1.7L (L for 2-32 psid)
2 M B EX: UPB (UP in bypass) EX: 2.5H (H for 5-60 psid)
3 C EX: XUP-UPB (both) EX: V4
3T D
* TE from IMI FDI is included by including a "T" after
the 3 in the model # EX: UB (for shutoff kit)
Example: SK2MA-2F-1M-2F-V1 would include … (bagged and tagged)
UAA - V1 – 075F - 050UM (manual balancing valve with single reduction to ATC – fixed female X union male)
UP 050F - 050M - PT - AV (union with PT and air vent - female x male)
YC 075FF - PT - HN (strainer with PT and drain, female x female)
![Page 3: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/3.jpg)
Quick Reference Guide to Base Model Numbers for Drawings
Base Model Description
SK1AA 1 Way Automatic Hookup (no ATC) & standard length accessories; AC/YC
SK1AB 1 Way Automatic Hookup (no ATC) & extended accessories; AC/YC extended
SK1AC 1 Way Automatic Hookup (no ATC), standard length accessories, & hoses; AC/YC & 2’ hoses
SK1AD 1 Way Automatic Hookup (no ATC), extended accessories, & hoses; AC/YC extended & 2’ hoses
SK1MA 1 Way Manual Hookup (no ATC) & standard length accessories; UA/YC
SK1MB 1 Way Manual Hookup (no ATC) & extended accessories; UA/YC extended
SK1MC 1 Way Manual Hookup (no ATC), standard length accessories, & hoses; UA/YC & 2’ hoses
SK1MD 1 Way Manual Hookup (no ATC), extended accessories, & hoses; UA/YC extended & 2’ hoses
SK2AA 2 Way Automatic Hookup & standard length accessories; AC/YC/UP
SK2AB 2 Way Automatic Hookup & extended accessories; AC/YC/UP extended
SK2AC 2 Way Automatic Hookup, standard length accessories, & hoses; AC/YC/UP & 2’ hoses
SK2AD 2 Way Automatic Hookup, extended accessories, & hoses; AC/YC/UP extended & 2’ hoses
SK2MA 2 Way Manual Hookup & standard length accessories; UA/YC/UP
SK2MB 2 Way Manual Hookup & extended accessories; UA/YC/UP extended
SK2MC 2 Way Manual Hookup, standard length accessories, & hoses; UA/YC/UP & 2’ hoses
SK2MD 2 Way Manual Hookup, extended accessories, & hoses; UA/YC/UP extended & 2’ hoses
SK3AA 3 Way Automatic Hookup & standard length accessories; includes manual valve for bypass & port in strainer for bypass line
SK3AB 3 Way Automatic Hookup & extended accessories; includes manual valve for bypass & port in strainer for bypass line
SK3AC 3 Way Automatic Hookup, standard length accessories & hoses; includes manual valve for bypass & port in strainer for bypass line
SK3AD 3 Way Automatic Hookup,extended accessories & hoses; includes manual valve for bypass & port in strainer for bypass line
SK3MA 3 Way Manual Hookup & standard length accessories; includes manual valve for bypass & port in strainer for bypass line
SK3MB 3 Way Manual Hookup & extended accessories; includes manual valve for bypass & port in strainer for bypass line
SK3MC 3 Way Manual Hookup, standard length accessories & hoses; includes manual valve for bypass & port in strainer for bypass line
SK3MD 3 Way Manual Hookup,extended accessories & hoses; includes manual valve for bypass & port in strainer for bypass line
SK3AA(T) 3 Way Automatic Hookup & standard length accessories; includes manual valve for bypass & assumes tee by others
SK3AB(T) 3 Way Automatic Hookup & extended accessories; includes manual valve for bypass & assumes tee by others
SK3AC(T) 3 Way Automatic Hookup, standard length accessories & hoses; includes manual valve for bypass & assumes tee by others
SK3AD(T) 3 Way Automatic Hookup,extended accessories & hoses; includes manual valve for bypass & assumes tee by others
SK3MA(T) 3 Way Manual Hookup & standard length accessories; includes manual valve for bypass & assumes tee by others
SK3MB(T) 3 Way Manual Hookup & extended accessories; includes manual valve for bypass & assumes tee by others
SK3MC(T) 3 Way Manual Hookup, standard length accessories & hoses; includes manual valve for bypass & assumes tee by others
SK3MD(T) 3 Way Manual Hookup,extended accessories & hoses; includes manual valve for bypass & assumes tee by others
![Page 4: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/4.jpg)
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
SK1AA
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE, AIR
VENT, AND P/T PORTS
CO
IL
![Page 5: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/5.jpg)
SK1AB
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, EXT P/T PORT, EXT HOSE END DRAIN, CAP
AND RETAINER STRAP,
AND EXT HANDLE
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE, EXT AIR
VENT, EXT P/T PORTS,
AND EXT HANDLE
CO
IL
![Page 6: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/6.jpg)
SK1AC
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE, AIR
VENT, AND P/T PORTS
![Page 7: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/7.jpg)
SK1AD
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, EXT P/T PORT, EXT HOSE END DRAIN, CAP
AND RETAINER STRAP, AND EXT HANDLE
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE, EXT AIR
VENT, EXT P/T PORTS, AND EXT HANDLE
![Page 8: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/8.jpg)
SK1MA
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS,
AIR VENT, AND MEMORY STOP
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
CO
IL
![Page 9: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/9.jpg)
SK1MB
CO
IL
YC - COMBINATION BALL VALVE, Y-STRAINER
WITH UNION, EXT. HANDLE, EXT. P/T PORT, HOSE END DRAIN,
CAP, RETAINER STRAP
AND STEM EXT.
UA - UNIBODY
MANUAL VENTURI BALANCING VALVE
WITH EXT P/T PORTS, EXT. AIR VENT, EXT
HANDLE, AND MEMORY STOP
![Page 10: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/10.jpg)
SK1MC
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS,
AIR VENT, AND MEMORY STOP
![Page 11: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/11.jpg)
SK1MD
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION BALL VALVE, Y-STRAINER
WITH UNION, EXT. HANDLE, EXT. P/T PORT, HOSE END DRAIN,
CAP, RETAINER STRAP
AND STEM EXT.
UA - UNIBODY
MANUAL VENTURI BALANCING VALVE
WITH EXT P/T PORTS, EXT. AIR VENT, EXT
HANDLE, AND MEMORY STOP
![Page 12: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/12.jpg)
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
SK2AA
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
CO
IL
![Page 13: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/13.jpg)
ATC
BY OTHERS
SK2ABC
OIL
UP - UNION
WITH MANUAL AIR
VENT, STEM EXT.
AND EXT. P/T PORT
AC - AUTOFLOW AUTOMATIC BALANCING VALVE WITH UNION,
SHUTOFF VALVE, EXT P/T PORTS, AND EXT HANDLE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, EXT P/T PORT, EXT HOSE END DRAIN, CAP
AND RETAINER STRAP, AND EXT HANDLE
![Page 14: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/14.jpg)
SK2AC
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR
VENT AND P/T PORT
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
![Page 15: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/15.jpg)
SK2AD
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR
VENT, STEM EXT.
AND EXT. P/T PORT
AC - AUTOFLOW AUTOMATIC BALANCING VALVE WITH UNION,
SHUTOFF VALVE, EXT P/T PORTS, AND EXT HANDLE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, EXT P/T PORT, EXT HOSE END DRAIN, CAP
AND RETAINER STRAP, AND EXT HANDLE
![Page 16: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/16.jpg)
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
SK2MA
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
CO
IL
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 17: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/17.jpg)
ATC
BY OTHERS
SK2MBC
OIL
UP - UNION
WITH MANUAL AIR
VENT, STEM EXT.
AND EXT. P/T PORT
UA - UNIBODYMANUAL VENTURI BALANCING
VALVE WITH EXT P/T PORTS, EXT
HANDLE, AND MEMORY STOP
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION, EXT P/T PORT,
EXT HOSE END DRAIN, CAP AND RETAINER
STRAP, AND EXT HANDLE
![Page 18: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/18.jpg)
SK2MC
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN, CAP
AND RETAINER STRAP
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR
VENT AND P/T PORT
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 19: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/19.jpg)
SK2MD
CO
IL
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
FIXED MALE
MALE SWIVEL
H2 - STAINLESS STEEL
BRAIDED HOSE
ATC
BY OTHERS
UP - UNION
WITH MANUAL AIR
VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, EXT P/T PORT, EXT HOSE END DRAIN, CAP
AND RETAINER STRAP, AND EXT HANDLE
UA - UNIBODYMANUAL VENTURI BALANCING
VALVE WITH EXT P/T PORTS,
EXT HANDLE,
AND MEMORY
STOP
![Page 20: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/20.jpg)
SK3AA
ATC
BY OTHERS
PIPING
BY OTHERS
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, T2 BYPASS ADAPTER, P/T PORT, HOSE
END DRAIN , CAP AND RETAINER STRAP
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
CO
IL
T2
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
![Page 21: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/21.jpg)
SK3(T)AA
ATC
BY OTHERS
PIPING
BY OTHERS
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
CO
IL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN , CAP AND
RETAINER STRAP
![Page 22: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/22.jpg)
SK3AB
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
T2
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
AC - AUTOFLOW AUTOMATIC
BALANCING VALVE WITH
UNION, SHUTOFF VALVE,
EXT P/T PORTS, AND EXT HANDLE
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
![Page 23: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/23.jpg)
SK3(T)AB
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
AC - AUTOFLOW AUTOMATIC
BALANCING VALVE WITH
UNION, SHUTOFF VALVE,
EXT P/T PORTS, AND EXT HANDLE
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
![Page 24: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/24.jpg)
SK3AC
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, T2 BYPASS ADAPTER, P/T PORT, HOSE
END DRAIN , CAP AND RETAINER STRAP
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
![Page 25: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/25.jpg)
SK3(T)AC
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
AC - AUTOFLOW AUTOMATIC BALANCING
VALVE WITH UNION, SHUTOFF VALVE,
AND P/T PORTS
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN , CAP AND
RETAINER STRAP
![Page 26: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/26.jpg)
SK3AD
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
AC - AUTOFLOW AUTOMATIC BALANCING VALVE WITH UNION,
SHUTOFF VALVE, EXT P/T PORTS, AND EXT HANDLE
![Page 27: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/27.jpg)
SK3(T)AD
ATC
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
AC - AUTOFLOW AUTOMATIC BALANCING VALVE WITH UNION,
SHUTOFF VALVE, EXT P/T PORTS, AND EXT HANDLE
![Page 28: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/28.jpg)
SK3MA
ATC
BY OTHERS
PIPING
BY OTHERS
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, T2 BYPASS ADAPTER, P/T PORT, HOSE
END DRAIN , CAP AND RETAINER STRAP
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
CO
IL
T2
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 29: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/29.jpg)
SK3(T)MA
ATC
BY OTHERS
PIPING
BY OTHERS
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
CO
IL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN , CAP AND
RETAINER STRAP
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 30: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/30.jpg)
SK3MB
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
T2
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
UA - UNIBODYMANUAL VENTURI BALANCING
VALVE WITH EXT P/T PORTS, EXT
HANDLE, AND MEMORY STOP
![Page 31: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/31.jpg)
SK3(T)MB
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
UA - UNIBODYMANUAL VENTURI
BALANCING VALVE WITH EXT P/T PORTS,
EXT HANDLE, AND MEMORY STOP
![Page 32: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/32.jpg)
SK3MC
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, T2 BYPASS ADAPTER, P/T PORT, HOSE
END DRAIN , CAP AND RETAINER STRAP
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 33: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/33.jpg)
SK3(T)MC
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
UP - UNION
WITH MANUAL AIR VENT
AND P/T PORT
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
AND MEMORY STOP
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
YC - COMBINATION SHUTOFF VALVE, Y-STRAINER
WITH UNION, P/T PORT, HOSE END DRAIN , CAP AND
RETAINER STRAP
UA - UNIBODY MANUAL VENTURI BALANCING
VALVE WITH P/T PORTS, AND MEMORY STOP
![Page 34: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/34.jpg)
SK3MD
ATC
BY OTHERS
PIPING
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
UA - UNIBODYMANUAL VENTURI BALANCING
VALVE WITH EXT P/T PORTS, EXT HANDLE, AND MEMORY STOP
![Page 35: IMI Flow Design Standard Kits...IMI Flow Design Standard Kits Pre-configured Automatic and Manual Coil Hook-up Kits . Standard Kit Ordering Instructions NOTE: If ordering just (1)](https://reader034.vdocument.in/reader034/viewer/2022051902/5ff1b980a70aac46607a3aaa/html5/thumbnails/35.jpg)
SK3(T)MD
ATC
BY OTHERS
CO
IL
FIXED MALE
FIXED MALE
H2 - STAINLESS STEEL
BRAIDED HOSE
H2 - STAINLESS STEEL
BRAIDED HOSE
MALE SWIVEL
MALE SWIVEL
PIPING BY OTHERS
EXTRA UNION & TEE
BY OTHERS OR IMI FDI
UB- UNIBODY SHUTOFF
VALVE WITH UNION,
EXT HANDLE
AND MEMORY STOP
UP - UNION WITH MANUAL
AIR VENT, STEM EXT.
AND EXT. P/T PORT
YC - COMBINATION SHUTOFF VALVE,
Y-STRAINER WITH UNION,
EXT P/T PORT, EXT HOSE END DRAIN,
CAP AND RETAINER STRAP, AND EXT HANDLE
UA - UNIBODYMANUAL VENTURI BALANCING VALVE WITH EXT P/T PORTS,
EXT HANDLE, AND MEMORY STOP