IMPLANT OCCLUSION
Sulieman Al-Johany BDS, MSDDiplomate, American Board of Prosthodontics
June 25, 2009
College of DentistryKing Saud University
Is implant differ?
• Vertical Movement Initial vertical tooth movement→ 28 µmImmediate rebound → 7 µm (4 hours for full recovery) Muhlemann HR. Tooth mobility: a review of clinical aspects and research findings. J Periodont 1967,38:686-708
Implant vertical movement → 2-3 µm 10 µm Sekine H et al. Mobility characteristics and tactile sensitivity of osseointegrated fixture-
supporting systems. In van Steenberghe D, editor: Tissue integration in oral maxillofacial reconstruction, Amsterdam, 1986, Elsiver
• Horizontal MovementNatural teeth: 56-108 µm
Parfitt GS. Measurement of the physiologic mobility of Individual teeth in an axial Direction. J Dent Res 1960,39:608-12
• Implant: 12- 66 µm Sekine et al. 1986
• 40 to 115 µm in M-D direction• 11 to 66 µm in B-L direction Komiyama Y. Clinical and research experience with osseointegrated implants in
Japan.In Albrektsson T, Zarb G, editor: The Branemark osseointegrated implant, Chicago,1989, Quintessence
Rangert and Colleagues suggested that part of this movement may be due to component flexure
Rangert B et al. Vertical load distribution on a three-unit prosthesis supported by a natural
tooth and a single Branemark implant: an in vivo study. Clin Oral Implants Res 1995,6:40-6
• Crestal bone loss around implant Occlusal overload on implant may increase the
incidence of marginal bone loss
Misch CE et al. A positive Correlation between occlusal trauma and peri-implant bone loss: Literature review. Imp Dent 2005;14:108-16
• In the presence of peri-implant mucosal health, a period of 8 months of excessive occlusal load on titanium implants did not result in loss of osseointegration or marginal bone loss when compared with non-loaded implants.
Heitz-Mayfield L. et al. Does excessive occlusal load affect osseointegration? An experimental study in dog. Clin Oral Imp Res 2004,15:259-68
The primary concern has now shifted to the durability and lifespan of the prosthesis. Maintenance issues with implant-supported prosthesis are strongly related to occlusal loading
Goodacre C. et al. Clinical complications with implants and Implant prostheses. J Prosth Dent 2003 ;90(2): 121-32