Improved Image Reconstruction Software for safer and less expensive Tomographic Scanning (CT, PET, SPECT) CT = Computed Tomography PET = Positron Emission Tomography SPECT = Single-Photon Emission Computed Tomography 1

Upload: others

Post on 19-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Improved Image Reconstruction Software

for safer and less expensive Tomographic Scanning(CT, PET, SPECT)

CT = Computed TomographyPET = Positron Emission TomographySPECT = Single-Photon Emission Computed Tomography

1

Page 2: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

The Problem

• Medical imaging using ionizing radiation saves lives

• Ionizing radiation is harmful*

• Tomographic imaging techniques are the most usefulbut cause the most harm (excluding MRI)

- Powerful diagnostic technique for cardiology, oncology, neurology, other- CT, PET and SPECT

* From GE Healthcare web page: “You and your patients continue to demand lower dose, but not at the expense of diagnostic image quality.”

- Can damage DNA, increasing a person’s lifetime risk of developing cancer

- CT scan is equivalent to 100 – 800 chest X-rays- PET/SPECT scan is equivalent to 10 – 2,050 chest X-rays

2

Page 3: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

The Opportunity

• Reducing radiation dose in tomographic scanning is a current top priority of the NIH

- Exposure to ionizing radiation for diagnostic purposes has nearly doubled in US between 1960 and 2006

• From 3.6 mSv to 6.3 mSv

• Scanner throughput is a function of dose and time

- Only way to reduce patient time in expensive equipment is to increase dose or increase imaging sensitivity

3

Page 4: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

The Solution

Powerful new image reconstruction algorithm for CT, PET, and SPECT

• Based on previously unidentified mathematical relations between special orthonormal basis functions

• Significant reduction (by the order of magnitude) in required scanning data without degrading image quality

Much lower radiation dose, scanning time and angular range

• Applicable to different scanning geometries (parallel-beam, fan-beam, cone-beam, etc.) for 2D and 3D reconstruction

• Patent pending

4

Page 5: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Inverse Radon Transform based on new algorithm

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

from 20 parallel-beam projections (within 60 range)

The new proprietary algorithm requires about 9 times lower radiation dose to produce the same image quality as current standard-of-care CT reconstruction engines

Original Phantom

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000

-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

180/20 = 9

Inverse Radon Transform based on Filtered Back Projection

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000

-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

from 180 parallel-beam projections (within 180 range) 5

Page 6: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

Inverse Radon Transform based on new algorithm

from 29 parallel-beam projections (within 29 range)

Original Phantom

180/29 6.2

Inverse Radon Transform based on Filtered Back Projection

from 180 parallel-beam projections (within 180 range)

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

X

Y

0 500 1000 1500 2000

200

400

600

800

1000

1200

1400

1600

1800

2000-0.2

-0.15

-0.1

-0.05

0

0.05

0.1

0.15

Medical Imaging and Industrial CT Applications

6

Page 7: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

X

Y

0 200 400 600 800 1000

100

200

300

400

500

600

700

800

900

1000-0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

0.25

0.3

X

Y

0 200 400 600 800 1000

100

200

300

400

500

600

700

800

900

1000 -0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

0.25X

Y

0 200 400 600 800 1000

100

200

300

400

500

600

700

800

900

1000 -0.15

-0.1

-0.05

0

0.05

0.1

0.15

0.2

0.25

Robustness to Noise

Inverse Radon Transform based on new algorithm

Original Phantom

Inverse Radon Transform based on Filtered Back Projection

180/20 = 9

from 20 parallel-beam projections (within 60 range)

from 180 parallel-beam projections (within 180 range) 7

Page 8: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

• 2D/3D Reconstruction Engine:

- Software and hardware which converts raw data into 2D/3D models to allow lower dose diagnoses- Incorporates AlgoTerra’s proprietary algorithm which requires significantly less scan data for accurate

reconstruction

• Business Models:

- Aftermarket device sales: plug and play replacement for current 2D/3D reconstruction hardware and software

- SaaS provider: radiologist sends raw 2D scanner data, company sends back 3D reconstruction

- License: license algorithm and software to CT, PET, and SPECT equipment manufacturers

Business Proposition

8

Page 9: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

CT, PET, SPECT scanner

Image display

Drop-inReplacementReconstructionEngine

Current Reconstruction

Engine*

Post-reconstruction

Image Processor

DICOM DICOM

DICOM DICOM

OR

Reconstruction provided over the Internet (SaaS)

Intern

et DICOM

Intern

etDICOM

* The current reconstruction engine may be incorporated into the scanner or a separate computing device

DICOM (Digital Imaging and Communications in Medicine) is a standard for handling, storing, printing, and transmitting information in medical imaging, and includes a file format definition and a network communications protocol. It is used by all CT, PET, SPECT and MRI scanner manufactures.

9

Page 10: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Markets

CT scanning

CT systems market had revenues of $4,336.0M in 2016 across the 39 major markets (US, France, Germany, Italy,

Spain, UK, Japan, Brazil, China, India, South Korea, Australia, Canada, Mexico, Russia, Austria, Belgium, Czech

Republic, Denmark, Finland, Greece, Hungary, Ireland, Netherlands, Norway, Poland, Portugal, Sweden,

Switzerland, Turkey, Taiwan, New Zealand, Argentina, Chile, Egypt, Israel, Saudi Arabia, South Africa, and the

United Arab Emirates). It is predicted that, by the end of 2023, the global CT systems market will increase to

$12,135.2M, with a Compound Annual Growth Rate (CAGR) of 18.2%.

The key drivers for the market are:

• Increased interest in high-slice CT systems due to wider applications and improved patient throughput

• High growth in the utilization of computed tomography, particularly in countries with emerging

economies such as China and India

• Strong anticipated growth in the number of annual CT scans due to increasing disease burdens and

aging populations

10

Page 11: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Nuclear Medicine Imaging Market

• PET/SPECT market: 6,390 units sold in 2015

• 2012 sales of PET/SPECT - $1,547B

( US: $444M; EU: $309M; Japan: $259M; China: $160M )*

• Installed base:

- in US: SPECT units – 13,000+; PET units – 2,000+

- Global growth rate: 3.0% CAGR (6.4% for PET in EU)

• PET – primarily used for oncology

- 70% of units sold are hybrid PET/CT scanners

- Avg. Price: Hybrid - $1.6M; PET alone - $750k

• SPECT – primarily used for cardiology

- 60% of SPECT units sold are hybrid SPECT/CY scanners

- Avg. Price: Hybrid - $413k; SPECT alone - $325k

* Frost & Sullivan 11

Page 12: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Other Markets

An increasing number of industries are discovering that X-ray CT scanning is a vital tool to ensure the highest product quality. Not only X-ray computed tomography can detect internal defects during a quality assurance process but it also permits a quantitative analysis of a defect as well, and the highly accurate 3D model can be compared with the original CAD data.

Industrial Non-Destructive Testing

Cargo Scanning andVehicle Screening

Baggage Screening

Mail and Parcel Inspection

Food Inspection

Industrial CT

Electronics Inspection

12

Page 13: Improved Image Reconstruction Software for safer and less …algotomo.com/AlgoTOMO_presentation.pdf · 2019. 2. 19. · X Y 0 500 1000 1500 2000 200 400 600 800 1000 1200 1400 1600

Contact Information

Alex DavydovTel: (301) 675-1137

Email: [email protected]

13