Page 1: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Improvement of efficiency by automation

[email protected]@wur.nl

Page 2: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

RIKILT

Page 3: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Mission

RIKILT contributes to the safety and health

of the Dutch food supply

Page 4: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Antibiotics

ongoing

Dioxins in chickenMay 1999

Melamine in Chinese (milk) products 2007- 2009

Nicotine in mushrooms

2009

Meltdown Tsjernobyl

April 1986DES in meat

1979

MPA in Dutch pig meat

Summer 2002

Chloorm

equat in

pears

1999

BSENovember 1986

Incidents:

Dioxins in Irish pork

2008 /2009

Dioxins in ………..

1999 - 2009

Dioxins in CPP 1998

Dioxins in milk 1989

Page 5: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

© FSAI

How did the dioxins get into the feed?How did the dioxins get into the feed?

Contaminated Contaminated Contaminated Contaminated Contaminated Contaminated Contaminated Contaminated

OilOilOilOilOilOilOilOil

BurnerBurnerBurnerBurnerBakery

Waste

Suspected Contamination source: Transformer Oil like Aroclor 1260

Page 6: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

© FSAI

•Nearly € 20 Billion Food Industry

•€ 8.16 Billion in Exports in 2008

•1,800 pig processing workers laid

off by 10th Dec

•10,000 Indirect Jobs Threatened

•Reputation Gone for Years

National economy under threatNational economy under threat……..

Page 7: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Automation of DIOXIN method

� Automation is needed :

� To increase sample throughput from 25 � 100 per week

� To reduce delivery time from 10-15 � 3 - 4 workings days

� To improve quality• Better reproducibility � reduction of measurement uncertainty• Better recovery• Etc

� To reduce costs

Page 8: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Method from 1989 -2005

Sample

Sample extraction

Extract clean�up

GC�HRMS

concentration

concentration

spike with 13C labelled standards←

add clean�up standard

add Recovery standards

Page 9: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Extraction and Clean-up 1989-2005

Semi automated system; combination of three columns using three different HPLC based systems

GPC� Al2O3 � CarbonSoxhlet

In between evaporation is necessaryIn between evaporation is necessaryIn between evaporation is necessaryIn between evaporation is necessary

Page 10: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Concentration

� First evaporation step using the Rotavapor:

From 100 ml to < 5 ml

Takes 15 min

Page 11: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Concentration

� Second evaporation step using the Pierce heating module:

5 ml � 10 µl in six steps

Takes at least 45 min.

Page 12: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Cost of DIOXIN analysis; approach (1989-2005)

� Serie : n =25 +QC

� Sample prep 3 FTE (MBO)

� Measurement using GC-HRMS; 2 FTE (HBO)

� Supervision; 0,5 FTE (scientist)

Page 13: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Cost of instrument

((price / depletion) + maintenance + C))

--------------------------------------------------------- = € xx per day

Days of use

Page 14: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Cost of instrument

((2*350.000 / 5) + (10% van 700.000) + 25000))

--------------------------------------------------------- = € 1500 per day

160

Page 15: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Cost of DIOXIN analysis 1989-2005

� Cost of instrument = € 7.500,--

� Cost of labour = € 20.750,--

� Cost of chemicals = € 2.500,--

� Cost for sample handling = € 825,--

� Total cost = € 30.325,--

� Per sample € 1.200,--

25 samples

Page 16: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Method from 2005

Sample

Sample extraction

Clean�up

GC�HRMS

concentration

concentration

spike with 13C labelled standards←

add clean�up standard

add Recovery standards

Page 17: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Main Transducer

Pump

Transducer

G

Extract collector

Pressure Gauge

PLE cell.

Solvents

PRESS. Relief Valve

Inlet Valve

Nitrogen

Output valve

Nitrogen Valve

Calibration Valve

5 ml loop

Main Transducer

Pump

Transducer

G

Extract collector

Pressure Gauge

PLE cell.

Solvents

PRESS. Relief Valve

Inlet Valve

Nitrogen

Output valve

Nitrogen Valve

Calibration Valve

5 ml loop

Automated Extraction

Page 18: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Method from 2005

Sample

Sample extraction

Clean�up

GC�HRMS

concentration

concentration

spike with 13C labelled standards←

add clean�up standard

add Recovery standards

Page 19: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Clean�up after 2005

� Still a three step procedure, however:

� In�line by coupling a combination of four columns

• Acidified silica column + silica column (capacity 3 gram fat)

• Al2O3 column

• Carbon column

Page 20: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

PowerPrep

� Purification of ASE�extract

� Silica – oxidation of fat

� Al2O3 – removal of interferences

� Carbon separation ofa. PBDEs & MO�PCBs & Ind.

PCB’s

b. Dioxins & NO�PCBs

Page 21: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

21

12

1

2

2

Pump

P.S.

M2 Step 1: Wet Silica Column

1 2 3 4 5 6

1 2 3 4 5

common

com

M5

Alumina

Carbon

Reverse

Forward

M6com

com

M6

M7com

M7

M8

com

Waste

1. Hexane

2. 2% CH2CL2

3. 50% CH2CL2

4. EtAc/Benz

5. Toluene

6. Sample

1. PCDD

2. PCB

3. Fraction 1

4. Fraction 2

5. Fraction 3

6. Waste6

collectors

Power-Prep System/DioxinPCDDs/ PCDFs

Separation Program

1

M3

Silica

com

com

M421

21

21

21

com

com

com

21

21

Step Flow Volume M1 M2 M3 M4 M5 M6 M7 M81 10 50 0 1 1 2 2 0 0 6

M3

M4

M5

com

Legend:

M2 and M8: 6 Way Valves

M3 - M7: 2 Way Valves

POwerprep method rikilt.ppt

Page 22: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Clean�up after 2005

� Both fractions are automatically unattended concentrated using Turbovap (recovery standard and keeper is added)

� Endpoint = 500 ul

� Concentrated fractions are analysed on two GC�HRMS

� Fraction A 10 =l using LVI (Gerstel CIS 4)

� Fraction B 100 =l using LVI (Gerstel CIS 4)

Page 23: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Cost of DIOXIN analysis automated approach

� Cost of instrument = € 7.500,�� € 9.000,��

� Cost of labour = € 20.750,�� € 17.750,��

� Cost of chemicals = € 2.500,�� € 6.500,��

� Cost for sample handling = € 825,�� € 1.650,��

� Total cost = € 30.325,�� € 34.900,��

� Per sample € 1.200,�� � € 700,��

25 samples *1 50 samples *2

*1 Max capacity

*2 Can be increased to 100

Page 24: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

� Future

Page 25: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

100ml &nitrogen

On-lineevaporation

20mlsharp pulse

ECF Integrated System

Jef Focant

Page 26: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

� LIMS

Page 27: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

What is SQL*LIMS?

Laboratory

Tests (to be) performed

Tracking progress of samples from receipt until

tests are completed.

Information Management System

Use it to enter information about

Results.

Samples,

Page 28: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

� Data stored in an oracle database

� SQL*LIMS

� SQL*LIMS Client application

� Forms, ExcelResults, Reports

WEB based system

SQL*LIMS WAT IS DAT?

Page 29: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Approving

results

Sample receive

Performing

analyses

Principal

Keten van monster tot resultaat.

Workflow from sample to result.

Page 30: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Validation of the results and samples

Analyst.Stores the final results in SQLLIMS: Validation 1.

Specialist.Checks the final results on task�level according to laboratory�specifications: Validation 2.

Projectmanager.Checks the final results on sample� or submissions�level: according to the law. Validation 3.

Page 31: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Reporting sample(s) result(s)

Keten van monster tot resultaat.

Page 32: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Coupling GC-HRMS with LIMS

Page 33: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Radio activity; Coupling of “Gammaster” with LIMS

Page 34: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Summary / Conclusion

� Automation of method achieved by:

� Automated extraction (ASE /PLE)

� Automated clean-up (Power Prep)

� Automated concentration (Turbovap)

� LVI +ALEX (Gerstel)

� Coupling analytical instrument with LIMS

Page 35: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Summary / Conclusion

� Automation of method results in:

� Higher sample throughput (factor 4) with same

number of staff

� Shorter delivery time

� Better quality

� Reduction of cost

Page 36: Improvement of efficiency by automation traag.pdf · Automation of DIOXIN method Automation is needed : ... Calibration Valve 5 ml loop Automated Extraction. Method from 2005 Sample

Summary / Conclusion

� Coupling analytical instruments to LIMS results in: