in the name of god microwave technology for reshaping of cornea sh.hanjani , m.d ophthalmologist

7
IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani , M.D Ophthalmologist

Upload: rajah-merrill

Post on 30-Dec-2015

21 views

Category:

Documents


0 download

DESCRIPTION

IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani , M.D Ophthalmologist. Microwave for reshaping of cornea Microwave technology uses since 15 years. Currently in initial testing. Is known as keraflex . Single low energy microwave pulse lasting less than one second. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist

IN THE NAME OF GOD

Microwave Technology For Reshaping OF

Cornea

Sh.Hanjani , M.DOphthalmologist

Page 2: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist

Microwave for reshaping of cornea

- Microwave technology uses since 15 years.- Currently in initial testing.- Is known as keraflex.- Single low energy microwave pulse lasting less

than one second.- Energy applied in an annular pattern to

corneal mid-periphery.- Single pulse raises the temp of stroma to 65°

in the upper 150µ of stroma .- Evaporative cooling technique protect

epithelium and bowman’s membrane.

Page 3: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist

- Shrinkage of collagen applies tensile

stress to the central cornea causes

flattening and reduction of myopia.

- Refractive results depends to depth and

diameter of the induced collagen.

- More peripherally and deeper stromal

tensioning causes steepening the cornea

for correct hyperopia.

Page 4: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist
Page 5: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist

Total treatment time is about 2 seconds No pain Transient superficial haze is lost within

minutes First day post OP seems noting done. Keraflex corrections lifespan : 18-24

months , may extend with CCL Keraflex KXL for keratoconus. induced refractive effect as well as

stabilize the KC

Page 6: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist
Page 7: IN THE NAME OF GOD Microwave Technology For Reshaping OF Cornea Sh.Hanjani  , M.D Ophthalmologist

The protruding KC cone seen here is substantially de-centered and has a K reading of 52.7 diopters

Keraflex effected an 8.1 diopter reduction in the cone and a more prolate shaped cornea