G1.0
INDEX, LEGEND,
AND GENERAL
NOTES
SYMBOLS LEGEND
INTERIOR ELEVATION SYMBOL
COLUMN LOCATION IDENTIFICATION
EXTERIOR ELEVATION SYMBOL
EXISTING HEIGHT ELEVATION SYMBOL
NEW HEIGHT ELEVATION SYMBOL
1 1
NORTH ARROW
LOBBY100
1
1
1
FINISH/FIXTURE
1
DRAWING WHERE ELEVATION IS SHOWN
DIRECTION WHERE ELEVATION IS VIEWED
ROOM NUMBER
ROOM NAME
ROOM IDENTIFICATION
(SEE SCHEDULES)
SCHEDULE IDENTIFICATION
KEYED GENERAL NOTE
MARK (NUMBER)
MARK (NUMBER/LETTER)
DIRECTION WHERE SECTION IS VIEWED
DRAWING WHERE SECTION IS SHOWN
BUILDING SECTION SYMBOL
DRAWING WHERE SECTION IS SHOWN
DIRECTION WHERE SECTION IS VIEWED
WALL SECTION SYMBOL
ELEVATION IDENTIFICATION
DRAWING WHERE ELEVATION IS SHOWN
SECTION IDENTIFICATION (NUMBER)
SECTION IDENTIFICATION (NUMBER)
1
DETAIL IDENTIFICATION
DESCRIPTION
ELEVATION IDENTIFICATION
DOOR IDENTIFICATION
WINDOW IDENTIFICATION
DRAWING WHERE DETAIL IS SHOWN
MARK (NUMBER)
MARK (LETTER)
LOCATION OF ELEVATION
LOCATION OF ELEVATION
DETAIL SYMBOL
REVISION IDENTIFICATION
MARK (LETTER/NUMBER)
MARK (NUMBER)
WALL TYPE
0'-0"
RATED WALLS
8" CMU WALL
CONCRETE PANEL P3
DEMO WALL SYMBOL
WALL TO BE REMOVED
ONE HOUR
FIRE RATED BARRIER
MATCH LINE
UP or DN
STAIR DIRECTION SYMBOL
MTL STUD PARTITION WALL
W/ BATT INSULATION
MTL STUD PARTITION WALL
GENERAL NOTES
PROJECT SITE
PARCEL #:
15-25-18-0000-00300-0000
LOCATION MAP
N
A. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK BY THE CONTRACTOR. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED
BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL; PERFORMANCE BY THE CONTRACTOR SHALL BE REQUIRED ONLY TO THE
EXTENT CONSISTENT WITH THE CONTRACT DOCUMENTS AND REASONABLY INFERABLE FROM THEM AS BEING NECESSARY TO
PRODUCE THE INTENDED RESULTS.
B. ALL CONTRACTORS (GENERAL AND SUB) WILL COORDINATE THEIR WORK PRIOR TO INSTALLATION OF ANY ITEMS SHOWN ON THE
DRAWINGS.
C. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL SUBCONTRACTORS ALL NECESSARY INFORMATION. DO NOT GIVE
PARTIAL SETS TO SUBCONTRACTORS, AS COORDINATION WILL SUFFER..
D. ALL DRAWINGS WERE PREPARED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION 2017.
Alteration II
BUILDING CODE SUMMARY:
IIIB
County
StateCorporate
City
City/County
Proposed Use:
Parcel #:
Name of Project:
Owned By:
Code Enforcement
Jurisdiction:
Owner or Authorized Agent:
Business
Construction Type:
BUILDING DATA
NoSprinklers:
YEAR EDITION OF CODE:
Yes
Repairs
Business, BOccupancy:
Pasco County Sheriffs Tactical Lab
15-25-18-0000-00300-0000
Livestone Consulting, Inc.
FBC 2017 6th Edition, FPC 2017 6th Edition, FMC 2017 6th Edition, Fire Prevention
Code 2017 6th Edition, NEC 2011.
THESE DRAWINGS WERE PREPARED IN ACCORDANCE WITH AND SHALL COMPLY WITH
THE FOLLOWING:
2017 BUILDING CODE, BUILDING, PLUMBING, MECHANICAL
TO THE EXTENT REQUIRED BY THE
EXISTING BUILDING CODE.
2017 FIRE PREVENTION CODE, 5TH EDITION
2014 NATIONAL ELECTRICAL CODE
2015 NFPA 1
2015 NFPA 101
2013 NFPA 13, 13R, 13D
2013 NFPA 72
2014 NFPA 70 (UPDATED)
2017 CODES ARE 6TH EDITION
CODE REVIEW
Pasco
New Construction
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
Private
A CODE INFORMATION
N/A NOTE:
G1.0 INDEX, LEGEND & GENERAL NOTES
G1.1 SITE PLAN
G1.2 LIFE SAFETY PLAN
A1.0 PROPOSED FLOOR PLAN, DETAILS, AND NOTES
A2.0 FOUNDATION PLAN, DETAILS AND NOTES
A2.1 SECOND FLOOR FRAMING PLAN, DETAILS AND NOTES
A3.0 REFLECTED CEILING PLAN AND NOTES
A3.1 ELECTRICAL PLAN AND NOTES
A4.0 BUILDING ELEVATIONS AND NOTES
A4.1 BUILDING ELEVATIONS
M1.0 MECHANICAL SHEETS
M2.0 MECHANICAL SHEETS
M3.0 MECHANICAL SHEETS
E1.0 ELECTRICAL SHEETS
E2.0 ELECTRICAL SHEETS
E3.0 ELECTRICAL SHEETS
P1.0 PLUMBING SHEETS
P2.0 PLUMBING SHEETS
INDEX OF DRAWINGS
ARCHITECT:
LIVESTONE CONSULTING, INC.
2901 WEST BUSCH Blvd. STE. 204,
TAMPA, FL 33618
(813) 645-2612
WWW.LIVESTONECONSULTING.COM
PROJECT TEAM
B INDEX OF DRAWINGS
N/A NOTE:
D LOCATION INFORMATION
N/A NOTE:
C NOT USED
N/A NOTE:
SCOPE OF WORK
FLORIDA PRODUCT APPROVAL NUMBER:
MANUFACTURE PRODUCT NAME CATEGORY SUBCATEGORY APPROVAL NUMBER
EMC WINDOWS AND DOORS, LLC MEDIUM STILE STOREFRONT DOOR EXTERIOR DOORS SWINGING EXTERIOR FL-3204.1
(IMPACT) DOOR ASSEMBLIES
PGT INDUSTRIES SINGLE HUNG WINDOW WINDOW SINGLE HUNG FL-239.3-R26
SCHLAGE LOCK COMPANY, LLC EXPIDOOR METAL BUILDING DOOR EXTERIOR DOORS SWINGING EXTERIOR
/EXPIDOOR SYSTEM DOOR ASSEMBLIES FL-4031.1
YKK AP AMERICA YHS 50 PANEL WALLS STOREFRONTS FL-14218-R10
SIMPSON STRONG-TIES CBSQ STRUCTURAL COMPONENTS WOOD CONNECTORS FL-10860-R4
SIMPSON STRONG-TIES HU STRUCTURAL COMPONENTS WOOD CONNECTORS FL-10655-R4 / FL-10531-R4
NOTES:
1. ALL OTHER FLORIDA PRODUCT APPROVAL NUMBERS ARE TO BE SUBMITTED BY THE GENERAL CONTRACTOR AND ARE TO BE PROVIDED AS PART OF PLAN
REVIEW SUBMITTAL PACKET.
2. METAL BUILDING BY METAL BUILDING MANUFACTURER, INCLUSIVE OF ROOFING SYSTEM
THE CONSTRUCTION OF A PRE-ENGINEERED METAL BUILDING THAT WILL SERVE AS AN OFFICE
AND TRAINING BUILDING FOR PASCO SHERIFF CANINE UNIT. THIS BUILDING WILL NOT BE OPEN
TO THE PUBLIC AND IS FOR USE BY THE SHERIFF'S DEPARTMENT ONLY.
ENGINEER:
RENNA ENTERPRISES, INC.
3231 DRANE FIELD ROAD,
LAKELAND, FL 33811
(836) 646-1258
G1.1
SITE
PLAN
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
1 SITE PLAN
NA NOTE:
PROPOSED SITE
3,196 SF
32
73 SF
U
443 SF
U
UP
DOWN
447 SF
U
10
10
10
2
6
'
-
1
"
M
A
X
T
R
A
V
E
L
33
' - 5
"
MA
X T
RA
VE
L
3
8
'
-
9
"
M
A
X
T
R
A
V
E
L
G1.2
LIFE
SAFETY
PLAN AND
NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
2 LIFE SAFETY PLAN - GROUND FLOOR
3/16" = 1'-0" NOTE:
DENOTES MAXIMUM LOAD
PER EXTERIOR EGRESS ELEMENT
ROOM OCCUPANT LOAD
ROOM OCCUPANT LOAD NOT COUNTED (STORAGE, HALLWAY,
MECH, ETC.)
DENOTES PATH OF
TRAVEL & DISTANCE
2
U
LIFE SAFETY LEGEND
THE ARCHITECTURAL DRAWINGS ARE IN COMPLIANCE
TO THE BEST OF OUR KNOWLEDGE WITH
THE FOLLOWING CODES AND STANDARDS:
FLORIDA BUILDING CODE - BUILDING 2017, 6TH EDITION
FLORIDA BUILDING CODE - PLUMBING 2017, 6TH EDITION
FLORIDA BUILDING CODE - FUEL GAS 2017, 6TH EDITION
FLORIDA BUILDING CODE - MECHANICAL 2017, 6TH
EDITION
FLORIDA BUILDING CODE - ACCESSIBILITY 2017, 6TH
EDITION
NATIONAL ELECTRICAL CODE - 2014 EDITION
NFPA 101 LIFE SAFETY CODE W/ FLORIDA
MODIFICATIONS - 2015 EDITION
ASHRAE (STANDARD 90.1) - 2010 EDITION
FLORIDA FIRE PREVENTION CODE - 2014, 5TH EDITION
CLASSIFICATION OF WORK: NEW CONSTRUCTION
CONSTRUCTION TYPE: TYPE IIIB, NOT SPRINKLED
AREA LIMITATION: 19,000 SF PER STORY
HEIGHT LIMITATION: 3 STORIES, 55' MAX.
PROPOSED HEIGHT: 21'-0":
OCCUPANCY CLASSIFICATION: BUSINESS GROUP B
(PER FBC 304.1)
PROPOSED AREA : 4,000 SF
(CONDITIONED)
GROSS AREA : 4,000 SF (UNDER
ROOF)
PROPOSED FACILITY OCCUPANT LOAD: 32 PERSONS
PROPOSED # OF OUTDOOR FIXED SEATS: 0
EGRESS WIDTH:
OCCUPANT LOAD: 32 PERSONS
DOOR WIDTH REQUIRED: 6.4" (32 @ .2" PER
PERSON)
DOOR WIDTH PROVIDED: 180" (900 PERSONS)
MAXIMUM ALLOWABLE EXIT
ACCESS TRAVEL DISTANCE: 250' (W/O SPRINKLER
SYSTEM)
MAXIMUM TRAVEL DISTANCE: 38' - 9"
MIN. # OF EXITS FOR OCCUPANT LOAD: 2 (1-500
PERSONS)
# OF EXITS PROVIDED: 3
LIFE SAFETY GENERAL NOTES
GENERAL NOTES:
1. POST TACTILE SIGNAGE AS REQUIRED AT ALL MEANS OF EGRESS; REF. A/G1.3
THE GENERAL CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE
BARRIER FREE REQUIREMENTS FOR THE APPLICABLE STATES AND
THE AMERICAN DISABILITIES ACT (ADA) AND SHALL ENSURE THAT
THIS FACILITY WILL BE ACCESSIBLE ACCORDING TO THE STRICTER
REQUIREMENTS OF THE APPLICABLE STANDARDS. THE FOLLOWING
IS A PARTIAL LIST OF REQUIREMENTS.
1. DOOR HARDWARE SHALL BE MOUNTED BETWEEN 36" AND 42"
ABOVE FLOOR AND BE LEVER TYPE.
2. PROVIDE ALL APPLICABLE REQUIRED A.D.A. SIGNAGE
ADA NOTES:NFPA OCCUPANCY LOAD FACTOR:
USE SF / PERSON AREA OCCUPANTS
STORAGE 500 963 2
BUSINESS 100 3,196 32
TOTAL 34
ALL OCCUPANT FACTORS ARE BASED OFF NFPA 101: TABLE 7.3.1.2
NOTE:
1. UPPER FLOOR IS FOR GENERAL STORAGE ONLY. THIS AREA WILL NOT BE OCCUPIED
3 LIFE SAFETY PLAN - ATTIC
3/16" = 1'-0" NOTE:
4 NOT USED
N/A NOTE:
1 NOT USED
N/A NOTE:
4" CONCRETE WITH # 5 W.W.F.
CENTERED
EXTERIOR
SIDING PER
BUILDING
MANUFACTURE
4
1
4
"
STRUCTURAL
METAL COLUMN
BEYOND
3-5/8" 230 GA. METAL
BASE PLATE
1
2
" P.T. PLYWOOD; LEAVE
UNFINISHED
R19
INSULATION
3-5/8" 20 GA METAL
STUD; AT 24" O.C.
SEE FOOTERS ON SHEET A4.0
FOR MORE INFORMATION
CE
IL
IN
G H
EIG
HT
1
2'-0
"
TYPE "B"
CE
IL
IN
G H
EIG
HT
1
2'-0
"
TYPICAL DOUBLE HUNG
STOREFRONT DOOR
TYPICAL SINGLE HUNG
DOOR WITH VENT
TYPE "A"
TYPICAL SINGLE
HUNG DOOR
TYPE "C"
FLOOR
5
8
" GYP. WALL
BOARD OR TILE
BACKER BOARD
FINISHED
CEILING
3-5/8" 230 GA. METAL
BASE PLATE
3-5/8" 230 GA. METAL
BASE PLATE
201D
201A
201F
201B
201C
201E
202B
202A
202C
OPEN OFFICE/
CLASSROOM TRAINING
201
MECHANICAL ROOM
200
STORAGE AREA
202
STORAGE AREA
203
50'-0"
34'-5"15'-7"
80'-0"
37'-2"
23'-0"
19'-10"
50'-0"
19'-10"8'-0"13'-10"
80'-0"
67'-8"
12'-4"
8'-4"
10'-2"
4'-5"
10'-5"
12'-4"
6'-2"
4'-9"3'-5"4'-3"
50'-0"
11'-1"
6'-5"
4'-5" 4'-0"
UP
DOWN
A A
NOTE:
1. FINISHED FLOOR HEIGHT TO BE 9'-6" ABOVE GROUND FLOOR
2
A2.0
2
A2.0
A1.0
PROPOSED
FLOOR
PLAN
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
FLOOR FINISH NOTES:
DOOR SCHEDULE
NO.
CLASSROOM/TRAINING
SIZE
DOUBLE HUNG
TYPE
201B
GLASSLOCATION
NOTES:
1. ALL DOORS ARE TO BE INSTALLED TO MATCH SWING SHOWN ON FLOOR PLAN.
2. ALL INTERIOR INSWING/OUTSWING DOORS TO BE JELD-WEN COLONIST PRIMED (RIGHT-HAND OR LEFT-HAND) TEXTURED SOLID CORE MOLDED COMPOSITE MDF SINGLE PREHUNG INTERIOR DOOR,
OR EQUAL, UNLESS OTHERWISE SPECIFIED BY OWNER.
3. ALL INTERIOR DOORS TO BE UNDERCUT, NOT EXCEEDING
3
8
" ABOVE FINISH FLOOR, U.N.O.
4. EXTERIOR DOORS SHALL MEET WIND PRESSURE CRITERIA OF 145 MPH WIND ZONE; G.C. TO PROVIDE FLORIDA PRODUCT APPROVAL FOR THE DOORS AS REQUIRED .
5. ALL DOORS AND TRIM TO BE PAINTED PER OWNER'S REQUIREMENTS.
6. PROVIDE LOCK BOX FOR MASTER KEY TO MEET FIRE MARSHAL'S REQUIREMENTS.
CLASROOM/TRAINING 3'-0" x 7'-0"
201C
HARDWARE
CLASSROOM/TRAINING 3'-0" x 7'-0" SINGLE HUNG
201D NO
201A
SINGLE HUNG
DOUBLE HUNG
SINGLE HUNG
NO
CLASSROOM/TRAINING
CLASSROOM/TRAINING201E
202A
3'-0" x 7'-0"
YES
NO
NO
NO
ROLLER DOOR
REMARKS
NOSTORAGE AREA
202B
DOUBLE HUNG
6'-0" x 7'-0"
6'-0" x 7'-0"
10'-0" x 7'-0"
6'-0" x 7'-0"
DOOR HARDWARE SCHEDULE:
GROUP 1:
THREE HINGES
KEY LOCKED BOTH SIDES
EGRESS PUSH BAR
GROUP 3:
THREE HINGES
STANDARD KNOB
NOSTORAGE AREA DOUBLE HUNG
NOSTORAGE AREA ROLLER DOOR
6'-0" x 7'-0"
10'-0" x 7'-0"
201F CLASSROOM/TRAINING
202C
MECHANICAL NEEDS TO BE VENTED
MECHANICAL NEEDS TO BE VENTED
GROUP 1
GROUP 3
GROUP 3
GROUP 1
GROUP 1
GROUP 1
GROUP 3
GROUP 3
GROUP 1
WINDOW SCHEDULE:
NO. SIZE
4'-0" X 6'-0"
OBSCURE
1. ALL QUANTITIES AND SIZES SHALL BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO ORDERING
MATERIALS.
2. UNLESS OTHERWISE NOTED, WINDOW DIMENSIONS ARE NOMINAL; WINDOW MANUFACTURER SHALL
PROVIDE STOCK UNITS APPROXIMATING SIZES GIVEN AS CLOSELY AS POSSIBLE.
3. THE GENERAL CONTRACTOR SHALL COORDINATE WINDOW MANUFACTURER'S ACTUAL UNIT SIZES WITH
ROUGH OPENINGS AS REQUIRED FOR A PROPER FIT.
4. HEIGHT OF WINDOW SILL AND HEAD IS BASED FROM TOP OF CONCRETE SLAB OR FINISH SUBSTRATE,
NOT FINISH FLOOR.
5. WINDOW PROFILES ARE INTENDED TO BE GENERIC AND DO NOT REPRESENT A PARTICULAR
MANUFACTURER OR PRODUCT.
6. EXTERIOR WINDOWS SHALL MEET WIND PRESSURE CRITERIA OF 145 MPH WIND ZONE; THE GENERAL
CONTRACTOR IS TO PROVIDE FLORIDA PRODUCT APPROVAL FOR WINDOWS AS REQUIRED.
7. AFTER INSTALLATION, ALL WINDOWS SHALL HAVE LOW EXPANSION FOAM INSULATION SEALANT BETWEEN
PRODUCT AND WOOD BUCK FRAMING SO AS TO CREATE AN AIR-TIGHT SEAL.
8. INSTALL ALL WINDOWS PER MANUFACTURER'S RECOMMENDATIONS.
9. ALL WINDOWS SHALL TO BE LARGE MISSILE RATED IMPACT.
NO
REMARKSQUANTITY
2A
NOTES:
LINTELS
5 EXTERIOR WALL TYPE "B"
1/2"=1'-0" NOTE: TYPICAL EXTERIOR WALL TYPE "B" - LOCATED BETWEEN COLUMNS
3 TYPICAL DOOR TYPES
1/4" = 1'-0" NOTE:
BY BUILDING MANUFACTURER
4 TYPICAL INTERIOR WALL TYPE "A"
1/2"=1'-0" NOTE: TYPICAL INTERNALL WALL TYPE "A"
GENERAL NOTES:
1. ALL INTERNAL WALL TYPES ARE TO BE TYPICAL WALL TYPE A.
2. ALL EXTERNAL WALLS ARE TO BE TYPICAL WALL TYPE B.
3. GENERAL CONTRACTOR TO VERIFY ALL
4. SITE CONDITIONS BEFORE STARTING WORK.
5. DOOR SCHEDULE CAN BE FOUND ON A1.0.
DOOR TYPE
TYPE C
TYPE C
TYPE C
TYPE C
TYPE B
TYPE B
TYPE A
1. ALL FLOORING IS TO BE POLISHED
CONCRETE UNLESS OTHERWISE NOTED.
PLUMBING NOTES:
1. THERE IS TO BE NO PLUMBING IN THIS BUILDING.
2. ALL PLUMBING FIXTURES ARE LOCATED IN THE INDOOR
TRAINING FACILITY OFFICE BUILDING LOCATED NEXT DOOR.
2 PROPOSED FLOOR PLAN - GROUND FLOOR
3/16" = 1'-0" NOTE:
7 PROPOSED FLOOR PLAN - ATTIC
3/16" = 1'-0" NOTE:
1 NOT USED
N/A NOTE:
6 NOT USED
N/A NOTE:
F3
3
F3
3
F3
3
F3
3
F2 F2
1
2
2
2
2
2
F1
F1
F1
F1
F1
F1
80'
10'
26'-6"
7'
26'-6"
10'
10' 30' 10'
50'
25' 25'
20'
20'
20'
20'
7'
7'
3 3
3-5/8" 20 GA METAL
BASE PLATE
5
8
" TYPE X GYP. WALL
BOARD OR
3
4
" PLYWOOD
3-5/8" 20 GA METAL
STUD AT 24" O.C.
8" SIDING
BOARD
STRUCTURAL
METAL COLUMN
2'-3
1
4
"
2'-4
"
10'-0"
3-5/8" 20 GA METAL
BASE PLATE
5
8
" TYPE X GYP. WALL
BOARD OR
3
4
" PLYWOOD
3-5/8" 20 GA METAL
STUD AT 24" O.C.
8" SIDING
BOARD
STRUCTURAL
METAL COLUMN
2'-3
1
4
"
2'-4
"
7'-0"
(7) #5 BAR BOTH
WAYS; TOP AND
BOTTOM
(10) #5 BAR BOTH
WAYS; TOP AND
BOTTOM
SEE KEY NOTE 1
SEE KEY NOTE 1
5
8
" TYPE X
GYPSUM WALL
BOARD
18 GAUGE
STEEL BOX
HEADER
18 GAUGE
HORIZONTAL
BRACING; @ 24"
O.C.
18 GAUGE
STEEL FRAMING
2X4 P.T.
WOOD BASE
PLATE
2X4 P.T. WOOD
RAILING POST
U 3-5/8" 18
GAUGE METAL
TRACK
1
2
" PLYWOOD
COVERING
3
4
"
PLYWOOD
DECKING
2X2 P.T. WOOD
BALUSTER;
MAX. 4" APART
10'-4"
9'-6" T
O F
IN
IS
HE
D F
LO
OR
≈ 10'-7" T
O C
EN
TE
R O
F V
AU
LT
ED
C
EILIN
G
FLOOR
18 GAUGE
HORIZONTAL
BRACING
ENGINEERED
METAL BUILDING;
SEE SHOP
DRAWINGS FOR
MORE
INFORMATION
A2.0
FOUNDATION
PLAN, DETAILS,
AND NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
1 PROPOSED FOUNDATION PLAN
3/16" = 1'-0" NOTE:
FOOTER SCHEDULE:
NO. SIZE
2'-0" X CONTINUOUS 18"
DEPTH
F2
REINFORCEMENT
(3) #5 BARS CONTINUOUS
REMARKS
7'-0" X 7'-0"
F3
(7) #5 BARS BOTH WAYS TOP AND BOTTOM
10'-0" X 10'-0" 28" (10) #5 BARS BOTH WAY TOP AND BOTTOM
F1
28"
KEY NOTES:
1. 6" CONCRETE SLAB WITH 4" X 4" - W2.9 X W2.9 W.W.M. REINFORCEMENT AT
CENTER OF SLAB IN 3000 PSI CONCRETE OVER 6 MIL VAPOR BLOCK AND 6"
COMPACTED SAND BASE ON TERMITE TREATED CERTIFIED COMPACT SOIL.
2. CONTROL JOINTS SHALL BE APPROVED IN ALL SLABS ON EARTH BY MEANS OF
DEEP SAW CUTS, A MINIMUM OF
1
4
" OF SLAB DEPTH AT 20'-0" CONTINUOUSLY
O.C. EACH WAY, UNLESS NOTED OTHERWISE WITHIN 24 HOURS OF POUR.
3. #5 REBAR HAIR PIN WITH 10' LEGS AND 12" HOOKS.
3 FOOTER LOCATED AT COLUMN (TYP.)
1/2" = 1'-0" NOTE:
CONCRETE NOTES:
1. ALL REINFORCEMENT STEEL SHALL BE NEW BILLET STEEL CONFORMING TO AST. A615 GRADE 60.
2. UNLESS OTHERWISE NOTED, ALL DETAILING, FABRICATION AND PLACING OF REINFORCING STEEL SHALL CONFORM TO THE MANUAL OF STANDARD
PRACTICE FOR DETAILING REINFORCED CONVRETE MEMBERS.
3. LAB ALL REBAR SPLICINES WITH 41 X REBAR DIAMETERS, (12" MIN.) UNLESS OTHERWISE NOTED.
4. ALL CONCRETE SHALL DEVELOP A MINIMUM OF 3,000 PSI COMPRESSIVE STRENGTH IN 28 DAYS UNLESS OTHERWISE NOTED.
5. WIRE MESH REINFORCEMENT SHE BE WELDED SMOOTH WIRE FABRIC CONFORMING TO ANSI/AW D14 WITH A YELD STRENGTH OF 60,000 PSI.
6. WIRE MESH REINFORCEMENT SHALL LAB ONE FULL MESH +2" AND BE SECURELY WIRED AT EACH SIDE AND END.
7. MINIMUM COVER FOR REINFORCEMENT STEEL UNLESS OTHERWISE NOTED SHALL BE:
A - CONCRETE DEPOSITED AGAINST GRADE - 3"
B - CONCRETE EXPOSED TO THE WEATHER OR IN CONTACT WITH GROUND - 2"
C - SLAB AND WALLS NOT EXPOSED TO THE WEATHER - 3/4"
D - BEAMS COVER MAIN REINFORCING - 2"
E - SLAB ON GRADE (NOT STRUCTURAL) - AT CENTERLINE
F - COLUMNS COVER MAIN REINFORCING - 2"
8. WHEN POURING AND CURING CONCRETE THE MINIMUM TEMPERATURE SHALL BE 50° AND SHALL BE MAINTAINED AT LEAST 50° FOR SEVEN DAYS
2 STORAGE AREA BUILDING SECTION
1/2" = 1'-0" NOTE:
CONTROL JOINT NOTES:
1. CUT SLAB AS SOON AS AGGREGATE DOES NOT DISLODGE (MUST BE WITHIN THE SAME DAY AS CONCRETE
PLACEMENT)
2. HAND TOOL JOINT TO FACE OF WALL WHERE SAWCUT DOES NOT REACH
FOUNDATION NOTES:
1. ALLOWABLE SOIL BEARING CAPACITY IS 2,500 PSF.
2. CONCRETE SLAB SHALL BE 4" THICK (U.N.O) 3,500 PSI @ 28
DAYS WITH 6X6-W1.4/W1.4 W.W.R. (CENTERED) OVER 10 MIL
VAPOR RETARDER ON TERMITE TREATED, CLEAN
COMPACTED FILL (U.N.O.); (2) LAYERS W.W.F. WHERE NOTED.
3. ALL EXTERIOR THRESHOLDS SHALL BE IN ACCORDANCE W/
FLORIDA ACCESSIBILITY CODE 11-4.5.2.
4. SUB-GRADE SHALL BE WELL DRAINED AND OF UNIFORM
BEARING STRENGTH.
5. SUB-GRADE SHALL BE ROLLER COMPACTED TO MINIMUM 95%
PROCTOR DENSITY, UNLESS A HIGHER VALUE IS SPECIFIED
IN GEOTECHNICAL REPORT.
6. SUB-GRADE SHALL BE MOIST DURING CONCRETE
PLACEMENT.
7. THE TOP OF ALL FOOTERS IS TO BE PLACED 1'-6" MINIMUM
BELOW GRADE U.N.O.
8. CONTRACTORS SHALL ENSURE THAT CONCRETE COVER TO
REBAR IN THE SLAB IS IN ACCORDANCE WITH ACI316.
9. CONTRACTOR SHALL ENSURE THAT CONCRETE
CONSTRUCTION CONFORMS TO ACI 301 (CURRENT),
SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS, ACI 302 (CURRENT), GUIDE FOR CONCRETE
FLOOR AND SLAB CONSTRUCTION, AND ACI 318 (CURRENT),
BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE, AS MODIFIED HEREAFTER.
10. CONCRETE SUPPLIER SHALL PROVIDE A MIX RESULTING IN
MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS, (f'c = 3,000
PSI) AS MEASURED BY TESTING CYLINDRICAL SPECIMENS
PER ASTM C-39 (U.N.O.).
11. A LAYER OF 10 MIL VAPOR RETARDER SHALL BE PROVIDED
AS A VAPOR BARRIER UNDER THE SLAB (TAPE JOINTS: 6"
LAPPED AND TAPED).
12. PROVIDE
1
2
" THICK X 4" WIDE BITUMINOUS EXPANSION JOINT
MATERIAL (U.N.O.) AT ALL SURFACES WHERE EXTERIOR
SLABS ABUT FLOOR SLABS.
13. PROVIDE STEEL TROWEL FINISH FOR INTERIOR SLAB AREAS,
CREATE BROOM FINISH TEXTURE FOR EXTERIOR SLABS.
24"
(TYP.)
LIGHTWEIGHT STEEL
FLOOR JOIST
24"
(T
YP
.)
4X4 WOOD POST
FOR RAILING ABOVE
WOOD STAIR; SEE
STAIR FRAMING
6/A2.1 FOR MORE
INFORMATION
HORIZONTAL
BRACING; @ 24" O.C.
STAGGERED
GUARDRAIL POST
2X6 P.T. WOOD JOIT
DOUBLE 2X8 P.T.
WOOD RIM BEAM
DECKING
4X4 P.T. WOOD
POST
SIMPSON CBSQ44;
INSTALL PER
MANUFACTURER
3'-0" MIN.
34
" - 3
8"
PE
R L
OC
AT
IO
N
SE
E
FN
D.
PL
AN
2X6 P.T. WOOD
HORIZONTAL BRACING
9'-0"
34" - 38"
5
8
" TYPE X GYPSUM WALL BOARD
18 GAUGE STEEL BOX HEADER
18 GAUGE HORIZONTAL
BRACING; @ 24" O.C.
18 GAUGE STEEL FRAMING
2X4 P.T. WOOD BASE PLATE
2X4 P.T. WOOD RAILING POST
3-5/8" 18 GAUGE METAL TRACK
1
2
" PLYWOOD COVERING
5
8
" TYPE X GYPSUM WALL BOARD
3
4
" PLYWOOD DECKING
2X2 P.T. WOOD BALUSTER;
MAX. 4" APART
(2) 2X8 P.T.
WOOD JOIST
2X6 P.T. WOOD
JOIST
HORIZONTAL
WOOD BRACING
PRE-ENGINEERED
WOOD STAIR
STRINGER
STEEL FRAMING; SEE DETAIL 5/A2.1
FOR MORE INFORMATION
LOCATE POST BESIDE
STRUCTURAL STEEL
SUPPORT
BUILDING
STRUCTURAL STEEL
SUPPORT; SEE
MANUFACTURE
DRAWINGS FOR FINAL
LOCATION
SEE TYPICAL WOOD LANDING
DETAIL 3/A2.1 FOR MORE
INFORMATION
2X2 P.T. WOOD
BALUSTER
4X4 P.T. WOOD POST
2 BY WOOD RAILING
SEE TYPICAL WOOD LANDING
DETAIL 3/A2.1 FOR MORE
INFORMATION ON CONNECTION
TO SLAB
PRE-ENGINEERED
WOOD STAIR
4" M
AX
SE
PA
RA
TIO
N
34
" - 3
8"
34
" - 3
8"
1'-0"
MIN.
A2.1
SECOND
FLOOR FRAMING
PLAN, DETAIL
AND NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
5 STEEL DECKING FRAMING PLAN
1/4" = 1'-0" NOTE:
GENRAL NOTES:
4 NOT USED
NA NOTE:
3 TYPICAL STAIR LANDING DETAIL
1-1/2" = 1'-0" NOTE:
1 TYPICAL FLOOR JOIST AND RAILING DETAIL
1-1/2" = 1'-0" NOTE:
6 WOOD STAIR DECKING FRAMING PLAN
1/4" = 1'-0" NOTE:
7 NOT USED
N/A NOTE:
2 TYPICAL RAILING DEATIL
1/2" = 1'-0" NOTE:
UP
DOWN
OC
SD
OCSD
OC
LED-6
LED-
4
LED-
4
LED-
4
LED-
4
LED-6 LED-6
LED-6 LED-6 LED-6
LED-6 LED-6 LED-6
LED-6 LED-6 LED-6
LED-6
LED-6
FL
FL
FL
FL
EE
EE
EE
PX-03
9'-0"
PX-03
9'-0"
PX-03
9'-0"
OP
±9'-0"
OP
±18'-0"
OP
±18'-0"
A3.0
REFLECTED
CEILING PLAN
AND NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
REFLECTED CEILING PLAN NOTES:
1. IN THE MAIN AREA THE CEILING IS TO BE EXPOSED TRUSSES.
2. STORAGE ROOM AND MECHANICAL ROOM TO BE
5
8
" TYPE X GYPSUM
WALL BOARD CEILING @ 9'-0" A.F.F. U.N.O.
4. ALL LIGHTING SHOWN IS FOR REFERENCE ONLY; REFER TO
ELECTRICAL DRAWING BY ENGINEER FOR MORE INFORMATION.
LIGHTING SCHEDULE:
DESCRIPTION MANUFACTURER
LIGHTING SCHEDULE
CODE MODEL # REMARKS
1. PROVIDE ALL FIXTURES COMPLETE WITH LAMPS
2. PROVIDE ALL REQUIRED MOUNTING OR HANGING HARDWARE
3. THE QUANITIES SHOWN IN THE LIGHTING SCHEDULE ARE BASED ON THE NUMBER OF FIXTURES SHOWN IN THE CONSTRUCTION DOCUMENTS; REFER TO GENERAL NOTE #2 ON SHEET A2.1
LED-4 2' X 2' LED VOLUMETRIC WHITE TROFFER LIGHT ENVIROLITE EVTR22DI23WD
OC CEILING SENSOR LOW VOLTAGE BY PIR SWITCH MOTION DETECTOR, OCCUPANCY SENSOR
MOUNT, CEILING LIGHT SENSOR, WHITE
ENERLITES MPC-50L-STICKER
LED-6 VERIFY INSTALLATION WITH OWNER
TO BE LOCATED EXTERIOR OF THE BUILDING
VERIFY INSTALLATION WITH OWNER
FL GOOD EARTH LIGHTING 6.25-IN 2-HEAD LED WHITE SWITCH-CONTROLLED FLOOD LIGHT GOOD EARTH LIGHTING SE1092-WH3-00LF0-G
QUANTITIES
4
3
14
4
WIRE FOR DAYLIGHTING WITH MANUAL CUT OFF
4 NOT USED
N/A NOTE:
HVAC NOTES:
1. SEE MECHANICAL DRAWINGS FOR LOCATIONS OF AIR SUPPLY AND RETURNS.
2. GENERAL CONTRACTOR TO COORDINATE MECHANICAL DRAWINGS WITH
REFLECTED CEILING PLAN TO AVOID CONFLICT.
LEGEND:
SDSMOKE DETECTOR
LED-4
LED-6
4" X 4' LED TROFFER LIGHT
2 X 2 LED TROFFER LIGHT
EXTERIOR FLOOD LIGHT
FL
OCCUPANCY CENSOROC
2 NOT USED
N/A NOTE:
EMERGENCY EXIT FLOOD LIGHT
EE
1 FT. X 4 FT. 50-WATT INTEGRATED LED EDGE-LIT PANEL FLUSH MOUNT WRAPAROUND LIGHT
COMMERCIAL ELECTRIC 74031/HD-G2
EE COMBO 14-WATT WITH NICAD 9.6 VOLT BATTERY WHITE INTEGRATED LED EXIT SIGN AND
EMERGENCY LIGHT
COMMERCIAL ELECTRIC EECLEDRG120277 3
1 REFLECTED CEILING PAN - GROUND FLOOR
3/16" = 1'-0" NOTE:
3 REFLECTED CEILING PLAN - ATTIC
3/16" = 1'-0" NOTE:
CEILING FINISH SCHEDULE:
CODE MATERIAL MANUFACTURER PRODUCT INFORMATION REMARKS
PX-03 5/8" GYPSUM WALL
BOARD, TYPE X
AMERICAN GYPSUM N/A LIGHT ORANGE PEEL FINISH U.N.O.; PAINT WITH
SHERWIN WILLIAMS SW7006, EXTRA WHITE, FLAT
WALL AND CEILING FINISH CLASSIFICATION
CLASS A PER FBC 803
NOTES:
1. ANY MATERIAL SUBSTITUTES ARE TO BE SUBMITTED FOR APPROVAL BY ARCHITECT
2. COORDINATE AND VERIFY ALL CEILING FINISH INSTALLATIONS WITH MECHANICAL AND ELECTRICAL DRAWINGS TO AVOID OVERLAP; INCLUDING EMERGENCY EXIT FIXTURES, SUPPLY REGISTERS AND RETURN GRILLS - CONTACT
ARCHITECT WITH CONFLICTS
OP OPEN EXPOSED CEILING TRUSSES
UP
DOWN
TO SECOND
FLOOR
TO FIRST FLOOR
S
4
GF
I
S
S
3
S
S
4
S
4
S
3
GF
I
A3.1
ARCHITECTURAL
ELECTRICAL PLAN
AND NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
ELECTRICAL LEGEND:
GFI
S
DUPLEX OUTLET
GFI OUTLET; LOCATED @ 42" A.F.F.
UNLESS OTHERWISE NOTED
LIGHT SWITCH
3 WAY LIGHT SWITCH
GENERAL NOTES:
1. REFER TO LIGHTING SCHEDULE ON A2.0 FOR MORE
INFORMATION ON FIXTURE MAKE AND MODEL.
2. LIGHTING PLANS ARE FOR REFERENCE ONLY; ALL FINAL
DECISIONS ON QUANTITY, FIXTURE MAKE AND MODEL,
AND LOCATIONS ARE TO BE DETERMINED BY OWNER.
3. GENERAL CONTRACTOR'S ELECTRICIAN TO PROVIDE
COMPLETED DRAWINGS AND CALCULATIONS REQUIRED
BY THE AUTHORITY HAVING JURISDICTION.
4. GENERAL CONTRACTOR'S ELECTRICAL
SUB-CONTRACTOR TO PROVIDE PANEL SCHEDULE AND
ALL REQUIRED DOCUMENTATION TO THE AUTHORITY
HAVING JURISDICTION.
5. THE POWER SHOWN IS FOR GENERAL LOCATION
PURPOSES ONLY; CONTRACTOR TO PROVIDE
SUFFICIENT SERVICE AND CIRCUIT LOADING TO ALL
ELECTRICAL DEVICES.
6. ALL ELECTRICAL RECEPTACLES ARE TO BE MOUNTED @
18: AFF UNLESS OTHERWISE NOTED.
7. ALL FLOOD LIGHTS ARE TO BE ON A LIGHT SENSOR
CONNECTED TO A MANUAL CUT OFF SWITCH.
8. GENERAL CONTRACTOR TO COORDINATE WITH OWNER
ON FINAL LOCATION OF OUTLETS.
9. ALL ELECTRICAL SHOWN IS FOR REFERENCE ONLY;
REFER TO ELECTRICAL DRAWING BY ENGINEER FOR
MORE INFORMATION.
3
S
2 NOT USED
N/A NOTE:
4 NOT USED
N/A NOTE:
1 ELECTRICAL PLAN - GROUND FLOOR
3/16" = 1'-0" NOTE:
3 ELECTRICAL PLAN - ATTIC
3/16" = 1'-0" NOTE:
SIDING BY BUILDING MANUFACTURER
18'-0"
50'-0"
6'-0"
7'
2'-10"
7'-0"
6'-0"
1 X 3 P.T. ALUM. TRIM AROUND
DOORS AND WINDOWS
ROOF BY BUILDING MANUFACTURER;
SLOPE MAY VERY
20'-11"
7'-0"
10'-0"
ROLL UP METAL DOOR
18'-0"
50'-0"
20'-11"
1 X 3 P.T. ALUM. TRIM AROUND
DOORS AND WINDOWS
ROOF BY BUILDING MANUFACTURER;
SLOPE MAY VERY
A4.0
BUIDLING
ELEVATIONS
& NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
1 NORTH ELEVATION
1/4" = 1'-0" NOTE:
GENERAL NOTES:
1. BUILDING SIDING FINISH AND STYLE BY BUILDING MANUFACTURE.
2. ALL TRIM AROUND DOORS AND WINDOWS IS TO BE P.T. WOOD; PAINT COLOR TO BE SELECTED
BY OWNER.
4 NOT USED
N/A NOTE:
2 SOUTH ELEVATION
1/4" = 1'-0" NOTE:
3 NOT USED
N/A NOTE:
7'-0"
3'-0"
18'-0" F
LO
OR
H
EIG
HT
80'-0"
ROOF BY BUILDING MANUFACTURER;
SLOPE MAY VERY
SIDING BY BUILDING MANUFACTURER
20'-11"
12'-6"
18'-0" F
LO
OR
H
EIG
HT
7'-0"
6'-0"
7'-0"
80'-0"
ROLL UP METAL DOORROOF BY BUILDING
MANUFACTURER; SLOPE MAY VERY
SIDING BY BUILDING MANUFACTURER
20'-11"
9'-10" 10'-0" 17'-2"
A4.1
BUILDING
ELEVATIONS
& NOTES
C 2020 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
DATE ISSUED:
REVIEWED BY: GBL
DRAWN BY: JEM
PROJECT NUMBER
SHEET TITLE
DESIGNED BY: JEM
DESCRIPTIONNO. DATE
G19-0004-001
04/14/2020
www.LivestoneConsulting.com
GILAD LIVINGSTONE
AR 94331
PROJECT
PARCEL #:
15-25-18-0000-00300-0000
NEW CONSTRUCTION
INDOOR
OWNER
L1302130000320
L1302130000317
TRAINING
Pasco County
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
Phone: 813-345-2612
OPEN
Sheriff Department
7220 Osteen Road
New Port Richey, FL 34653
2 EAST ELEVATION
1/4" = 1'-0" NOTE:
3 NOT USED
N/A NOTE:
1 WEST ELEVATION
1/4" = 1'-0" NOTE:
4 NOT USED
N/A NOTE:
OPEN OFFICE/
STORAGE AREA
STORAGE AREA
MECH.
ROOM
PR
ELIM
IN
AR
Y, N
OT
F
OR
C
ON
ST
RU
CT
IO
N
M1.0
MECHANICAL
FLOOR PLAN
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
NEW CONSTRUCTION
OWNER
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
G19-0004-001
04/01/2019
PROJECT
XXXXX
XXXXX, FL 33XXX
NET
AREA Outdoor Based on Outdoor
S.F. Floor Area
Person(s)
CFM
Code
CFM
PR
ELIM
IN
AR
Y, N
OT
F
OR
C
ON
ST
RU
CT
IO
N
M2.0
MECHANICAL
SCHEDULES,
LEGEND AND
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
NEW CONSTRUCTION
OWNER
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
G19-0004-001
04/01/2019
PROJECT
XXXXX
XXXXX, FL 33XXX
NOTES
PR
ELIM
IN
AR
Y, N
OT
F
OR
C
ON
ST
RU
CT
IO
N
M3.0
MECHANICAL
DETAILS
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
NEW CONSTRUCTION
OWNER
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
G19-0004-001
04/01/2019
PROJECT
XXXXX
XXXXX, FL 33XXX
ABBREVIATION
AFG ABOVE FINISH GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AVAILABLE INTERRUPTING CURRENT
AL ALUMINUM
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIAL
AWG AMERICAN WIRE GAUGE
BLDG BUILDING
C. CONDUIT
C.T. CURRENT TRANSFORMER
CU COPPER
DISC. DISCONNECT SWITCH
EQ EQUAL
EQPT. EQUIPMENT
ETC. ET CETERA
EX EXISTING
GFI GROUND FAULT INTERRUPTER
GND GROUND
KV KILOVOLTS
KVA KILOVOLT AMPERES
KWH KILOWATT HOUR
MAX MAXIMUM
MIN. MINIMUM
MPH MILES PER HOUR
MTD. MOUNTED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
PRE-FAB PRE-FABRICATED
PVC POLYVINYL CHLORIDE
RGSC RIGID GALVANIZED STEEL CONDUIT
SCT SECTION
SYS SYSTEM
TYP. TYPICAL
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
WP WATERPROOF
XFMR TRANSFORMER
MANUAL MOTOR STARTER WITH THERMAL OVERLOAD
PROTECTION, NEMA TYPE 1 ENCLOSURE UNO.
GFIWP
4' STRIP FLUORESCENT LIGHTING FIXTURE.
2'X4' RECESSED MOUNTED FLUORESCENT LIGHTING
FIXTURE.
SYMBOL
ELECTRICAL SYMBOL LEGEND
SINGLE POLE TOGGLE SWITCH (DIMMING TYPE FOR
DINING AREA), "3" DENOTES 3-WAY SWITCH, 48" AFF.
LOWER CASE LETTER INDICATES SWITCH CONTROLS.
DUPLEX RECEPTACLE, "GFI" DENOTES GROUND FAULT
CIRCUIT INTERRUPTER (HUBBELL CAT. NO. GF5352-A,
"WP" DENOTES WEATHERPROOF OUTLET BOX & COVER
(TAYMAC CAT. NO. 72204, LOCKABLE & KEYED ALIKE), 18"
AFF UNO.
JUNCTION BOX, SIZE AS REQUIRED, 4" SQUARE MINIMUM.
FUSIBLE DISCONNECT SWITCH, HORSEPOWER RATED,
NEMA TYPE 1 ENCLOSURE UNO, "WP" DENOTES NEMA
TYPE 3R ENCLOSURE.
NON-FUSIBLE DISCONNECT SWITCH, HORSEPOWER
RATED, NEMA TYPE 1 ENCLOSURE UNO, "WP" DENOTES
NEMA TYPE 3R ENCLOSURE.
RECESSED MOUNTED PANELBOARD, 120/208V, 3Ø
DESCRIPTION
CIRCUIT HOMERUN
RECESSED MOUNTED COMPACT FLUORESCENT DOWN
LIGHT. CAPITAL LETTER INDICATE FIXTURE TYPE.
PENDANT MOUNTED LIGHTING FIXTURE.
COMBINATION CEILING MOUNTED FAN WITH LIGHTING
FIXTURE.
a
K
F
NF
SINGLE RECEPTACLE.
EXIT SIGN.
COMBINATION EXIT SIGN AND EMERGENCY LIGHTING
UNIT.
FAN SWITCH
WALL MOUNTED EMERGENCY LIGHTING UNIT.
CEILING MOUNTED EMERGENCY LIGHTING UNIT.
DATA OUTLET.
P
DOUBLE DUPLEX (QUAD) RECEPTACLE, "GFI" DENOTES
GROUND FAULT CIRCUIT INTERRUPTER, 18" AFF UNO.
GFI
SURFACE MOUNTED PANELBOARD, 120/208V, 3Ø
WET LOCATION WALL PACK
J
GENERAL PROJECT TECHNICAL NOTES:
1. CONDUCTORS NO. 8 AWG AND LARGER SHALL BE STRANDED. CONDUCTORS
NO. 10 AWG AND SMALLER SHALL BE SOLID. ALL CONDUCTORS SHALL BE
COPPER. MINIMUM SIZE FOR BRANCH CIRCUITS SHALL BE NO. 12 AWG.
COLOR SHALL BE GREEN FOR EQUIPMENT GROUNDING CONDUCTORS AND
WHITE FOR NEUTRALS. CONDUCTORS SHALL BE 600 VOLT, 75 DEGREE
INSULATION, TYPE "THHN/THWN".
2. TOGGLE SWITCHES: FS W-S-896, TOTALLY ENCLOSED WITH BODIES OF
THERMOSETTING PLASTIC AND MOUNTING STRAP. HANDLES SHALL BE
IVORY. WIRING TERMINALS SHALL BE SCREW TYPE, SIDE WIRED SWITCHES,
QUIET TYPE, 20 AMPERE, 120/277VAC, AND NUMBER OF POLES AS INDICATED.
UL LISTED TO FEDERAL SPECIFICATIONS.
3. RECEPTACLES: UL 498 AND NEMA WD 1, GENERAL GRADE, HEAVY DUTY,
GROUNDING TYPE, NEMA 5-20R CONFIGURATION. PROVIDE SCREW TYPE,
SIDE WIRED, WIRING TERMINALS. CONNECT GROUNDING POLE TO
MOUNTING STRAP.
4. CIRCUIT BREAKERS SHALL CONFORM TO FS W-C-376, UL 489, THERMAL
MAGNETIC TYPE WITH MINIMUM INTERRUPTING RATING AS SHOWN.
BREAKER DESIGN SHALL BE SUCH THAT OVERLOAD IN ONE POLE SHALL
AUTOMATICALLY CAUSES ALL POLES TO OPEN. MAINTAIN PHASE SEQUENCE
THROUGHOUT EACH PANEL SO THAT ANY TWO ADJACENT BREAKER POLES
ARE CONNECTED TO PHASE A AND B RESPECTIVELY. CIRCUIT BREAKERS
SHALL BE OF THE PLUG-ON TYPE WHERE AVAILABLE FROM THE
MANUFACTURERS.
5. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) RECEPATCLES: UL 943,
DUPLEX TYPE FOR MOUNTING IN STANDARD OUTLET BOX. DEVICE SHALL BE
CAPABLE OF DETECTING CURRENT LEAK OF 6 MILLIAMPERES OR GREATER
AND TRIPPING PER REQUIREMENTS OF UL 943 CLASS A GFCI DEVICES.
6. DEVICE PLATES: SMOOTH NYLON, STANDARD NEMA DESIGN, COLOR
MATCHING SCREWS. COLOR TO BE SELECTED BY OWNER.
7. OUTLET BOX SHALL CONFORM TO UL 514A, CADMIUM OR ZINC COATED,
FERROUS METAL.
8. DISCONNECT SWITCHES SHALL BE GENERAL DUTY TYPE, 240VAC,
HORSEPOWER RATED, FUSED OR NON-FUSED AS INDICATED, NEMA TYPE 1
ENCLOSURE (FOR INDOOR), NEMA TYPE 3R ENCLOSURE (FOR OUTDOOR),
WITH PADLOCK PROVISIONS AND CONFORMING TO NEMA KS-1.
9. PROVIDE CONDUCTOR IDENTIFICATION WITHIN EACH ENCLOSURE WHERE
TAP, SPLICE, OR TERMINATION IS MADE. FOR CONDUCTORS NO. 6 AWG AND
SMALLER DIAMETER, COLOR CODING SHALL BE BY FACTORY APPLIED,
COLOR IMPREGNATED INSULATION. FOR CONDUCTORS NO. 4 AWG AND
LARGER DIAMETER, COLOR CODING SHALL BE PLASTIC COATED, SELF
STICKING MARKERS; COLORED NYLON CABLE TIES AND PLATES; OR HEAT
SHRINK TYPE SLEEVES.
10. MAKE SPLICES IN ACCESSIBLE LOCATIONS. MAKE SPLICES IN CONDUCTORS
NO. 10 AWG AND SMALLER DIAMETER WITH INSULATED, PRESSURE TYPE
CONNECTOR IN ACCORDANCE WITH UL 486A OR UL 486C (TWISTED ON
SPLICING CONNECTOR). MAKE SPLICES IN CONDUCTOR NO. 8 AWG AND
LARGER MATERIAL WITH SOLDERLESS CONNECTOR IN ACCORDANCE WITH
UL 486A AND COVER WITH INSULATION MATERIAL EQUIVALENT TO
CONDUCTOR INSULATION.
11. INSTALL COVERS AND DEVICE PLATES WITH EDGES IN CONTINUOUS
CONTACT WITH FINISHED WALL SURFACES WITHOUT USE OF MATS OR
SIMILAR DEVICES. PLASTER FILLINGS ARE NOT PERMITTED. INSTALL
PLATES WITH ALIGNMENT TOLERANCE OF 1/6 INCH.
12. LIQUIDTIGHT FLEXIBLE CONDUIT SHALL BE STEEL (PVC JACKET)
CONFORMING TO UL 360 AND FITTINGS CONFORMING TO UL 1660.
13. ALL ELECTRICAL EQUIPMENT SHALL BE NEW (OBTAINED WRITTEN APPROVAL
FROM OWNER FOR REUSING EXISTING EQUIPMENT AND CONDUIT), UL
LISTED AND APPROVED FOR INTENDED USE.
14. ALL CONDUITS AND JUNCTION BOXES SHALL BE LABEL WITH BLACK
PERMANENT MARKER AT EACH ENDS INDICATING THE PANEL AND CIRCUIT
NUMBER(S).
15. PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR EACH 120V CIRCUIT.
16. WITHIN 30 DAYS AFTER THE DATE OF CERTIFICATE OF OCCUPANCY,
CONTRACTOR SHALL PROVIDE "AS-BUILT" ELECTRICAL DRAWINGS
DEPICTING THE ACTUAL ELECTRICAL FIELD INSTALLATIONS IN ACCORDANCE
WITH THE FBC 13-413.1.ABC.2.1.1 TO THE BUILDING OWNER.
17. WITHIN 30 DAYS AFTER THE DATE OF CERTIFICATE OF OCCUPANCY,
CONTRACTOR SHALL PROVIDE OPERATING MANUAL AND MAINTENANCE
MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER, INCLUDING
SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS
FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, CLEARLY
IDENTIFIED REQUIRED ROUTINE MAINTENANCE ACTIONS, AND NAMES AND
ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY PER FBC
13-413.1.ABC.2.2.1
18. THE FOLLOWING CONDUCTOR SIZES SHALL BE OBSERVED FOR ALL BRANCH
CIRCUITS:
CONDUCTOR SIZE 120V 208V
#12 AWG 0-70 FT 0-135 FT
#10 AWG 71-120 FT 136-220 FT
#8 AWG 121-315 FT 221-325 FT
19. CONDUCTORS SHALL HAVE THE FOLLOWING COLOR CODES:
VOLTAGE SYSTEM PHASE A PHASE B PHASE C NEUTRAL
120/208V, 3Ø, 4W BLACK RED BLUE WHITE
RECESSED MOUNTED LIGHTING CONTROL PANELBOARD
SMOKE DETECTORSD
GENERAL PROJECT TECHNICAL NOTES:
1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA 101, AND
STATE AND LOCAL CODE ORDINANCES.
2. DO NOT SCALE DRAWINGS, USE FIELD MEASUREMENTS.
3. CONTRACTORS SHALL VISIT THE SITE AND THOROUGHLY EXAMINE ALL
CONTRACT DOCUMENTS, DRAWINGS, AND DETAILS TO HAVE COMPLETE
UNDERSTANDING OF THE SCOPE OF THIS PROJECT AND ALL EXISTING
CONDITIONS BEFORE SUBMITTING THEIR PROPOSAL BID. ALSO, ANY
QUESTION, DISCREPANCY OR IRREGULARITY THAT A SUCCESSFUL
CONTRACTOR MAY HAVE OR FIND SHALL BE CLARIFIED PRIOR TO
CONTRACT FINALIZATION. FAILURE TO DO SO SHALL NOT RELIEVE THE
CONTRACTOR OF RESPONSIBILITY TO PERFORM ALL WORK AND ALL
MATERIALS AND EQUIPMENT REQUIRED FOR COMPLETE AND
SATISFACTORY INSTALLATION AS INTENDED BY THIS DESIGN AND THE
SCOPE OF THIS PROJECT.
4. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ADDITIONAL
GENERAL NOTES WHICH SHALL APPLY HERE.
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE
WITH ALL UTILITY COMPANIES.
6. VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK AND
NOTIFY THE GENERAL CONTRACTOR IF A CONDITION PREVENTS THE
INTENT OF THESE PLANS.
7. REFER TO ARCHITECTURAL PLANS AND SPECIFICATIONS FOR ADDITIONAL
GENERAL NOTES WHICH SHALL APPLY HERE.
8. NOTES ON DRAWINGS SHALL APPLY TO ALL SIMILAR CONDITIONS
WHETHER THEY ARE REPEATED OR NOT.
9. ELECTRICAL CONTRACTOR SHALL VERIFY TOTAL CONNECTED LOAD/HP
WITH MECHANICAL CONTRACTOR PRIOR TO WIRING OF ALL HVAC
EQUIPMENT. MAKE ANY CHANGES TO OVERCURRENT DEVICES OR
FEEDER SIZE PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL
CODE.
10. BOXES LOCATED ON OPPOSITE SIDES OF NON-FIRE RATED WALLS SHALL
BE OFFSET A MINIMUM OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES
OF FIRE RATED WALL SHALL BE OFFSET A MINIMUM OF 24" HORIZONTALLY.
"THRU-THE WALL" BOXES SHALL NOT BE ALLOWED WITHOUT PRIOR
WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.
11. ALL TEMPERATURE CONTROL WIRING SHALL BE FURNISHED AND
INSTALLED BY OTHERS.
12. ELECTRICAL CONTRACTOR SHALL VERIFY TOTAL CONNECTED LOAD/HP
WITH MECHANICAL CONTRACTOR PRIOR TO WIRING OF ALL HVAC
EQUIPMENT. MAKE ANY CHANGES TO OVERCURRENT DEVICES OR FEEDER
SIZE PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.
13. PROVIDE GROUNDING IN ACCORDANCE WITH THE LATEST NEC, IN
PARTICULAR ARTICLE 250. GROUND RESISTANCE SHALL NOT EXCEED 25
OHMS. PROVIDE INSULATED GREEN EQUIPMENT GROUNDING
CONDUCTORS FOR ALL RACEWAYS. GROUNDING CONDUCTORS SHALL BE
SEPARATE FROM ELECTRICAL SYSTEM NEUTRAL CONDUCTORS.
14. GROUNDING CONDUCTORS (ALL GROUNDING REQUIREMENTS) SHALL BE
INSTALLED AS DIRECTED BY EQUIPMENT MANUFACTURER AND AS SHOWN
ON DRAWINGS.
15. GROUND EXPOSED, NON-CURRENT CARRYING METALLIC PARTS OF
ELECTRICAL EQUIPMENT, METALLIC RACEWAY SYSTEMS, GROUNDING
CONDUCTOR IN METALLIC AND NON-METALLIC RACEWAYS, AND NEUTRAL
CONDUCTORS OF WIRING SYSTEMS AND IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE, ARTICLE 250.
16. PROVIDE LAMINATED PLASTIC NAMEPLATES FOR EACH PANELBOARD.
EACH NAMEPLATE INSCRIPTION SHALL IDENTIFY THE FUNCTION, AND,
WHEN APPLICABLE, THE POSITION. NAMEPLATE SHALL BE MELAMINE
PLASTIC, 0.125 INCH THICK, WHITE WITH BLACK CENTER CORE. SURFACE
SHALL BE MATTE FINISH. CORNERS SHALL BE SQUARE. ACCURATELY
ALIGN LETTERING AND ENGRAVE INTO THE CORE. MINIMUM SIZE OF
NAMEPLATES SHALL BE 1 X 2.5 INCHES. LETTERING SHALL BE A MINIMUM
OF 0.25 INCH HIGH NORMAL BLOCK STYLE. FASTEN NAMEPLATES TO THE
DEVICE WITH A MINIMUM OF TWO SHEET METAL SCREWS OR TWO RIVETS.
PROVIDE LAMINATED PLASTIC NAMEPLATES FOR EACH PIECE OF
EQUIPMENT BEARING THE AVAILABLE FAULT CURRENT AND DATE OF
CALCULATION. PROVIDE LAMINATED PLASTIC NAMEPLATES INDICATING
ALTERNATE POWER SOURCE TO SERVICE EQUIPMENT AND INDICATE
POINT OF ORIGINATION AND LOCATION.
17. ALL CONDUCTORS SHALL BE COPPER. MINIMUM SIZE FOR BRANCH
CIRCUITS SHALL BE NO. 12 AWG. COLOR SHALL BE GREEN FOR
EQUIPMENT GROUNDING CONDUCTORS AND WHITE FOR NEUTRALS.
CONDUCTORS SHALL BE 600 VOLT, 75° INSULATION, TYPE "THHN/THWN".
18. PROVIDE #10 AWG CONDUCTORS FOR PHASE, NEUTRAL, AND EQUIPMENT
GROUNDING CONDUCTORS FOR ALL 20A, 120V CIRCUITS EXCEEDING 75LF
AND IS IN COMPLIANCE WITH FBC 13-413.
19. SECURELY SUPPORT ALL EQUIPMENT AND CONDUITS INDEPENDENTLY OF
ALL OTHER SYSTEMS, PRIMARILY TO BUILDING STRUCTURE. UNLESS
INDICATED OTHERWISE, CONCEAL CONDUIT WITHIN FINISHED WALLS,
CEILING, OR FLOOR SLAB. INSTALL CONDUIT PARALLEL WITH OR AT RIGHT
ANGLES TO CEILINGS, WALLS, AND STRUCTURAL MEMBER.
20. PANELBOARD SHALL CONFORM TO UL 67 AND UL 50 AND SHALL BE
CIRCUIT BREAKER EQUIPPED. PROVIDE SEPARATE NEUTRAL AND
EQUIPMENT GROUND BUS. ALL BUS BARS SHALL BE COPPER.
21. INSTALL CONDUIT PARALLEL WITH OR AT RIGHT ANGLES TO CEILINGS,
WALLS, AND STRUCTURAL MEMBER. SUPPORT CONDUIT BY PIPE STRAPS,
WALL BRACKETS, HANGERS, OR CEILING TRAPEZE. FASTEN BY WOOD
SCREWS TO WOOD; BY TOGGLE BOLTS ON HOLLOW MASONRY UNITS; BY
STUDS, OR SPRING TENSION CLAMPS ON STEEL WORK. THREADED
C-CLAMPS MAY BE USED ON RIGID STEEL CONDUIT ONLY. DO NOT WELD
CONDUITS OR PIPE STRAPS TO STEEL STRUCTURES. LOAD APPLIED TO
FASTENERS SHALL NOT EXCEED ONE-FOURTH PROOF TEST LOAD.
FASTENERS ATTACHED TO CONCRETE CEILING SHALL BE VIBRATION
RESISTANT AND SHOCK RESISTANT. HOLES CUT TO DEPTH OF MORE
THAN 1-1/2 INCHES IN REINFORCED CONCRETE BEAMS OR TO DEPTH OF
MORE THAN 3/4 INCH IN CONCRETE JOINTS SHALL NOT CUT MAIN
REINFORCING BARS. FILL UNUSED HOLES.
22. MAKE CHANGES IN DIRECTION OF RUNS WITH SYMMETRICAL BENDS OR
CAST METAL FITTINGS. MAKE FIELD MADE BENDS AND OFFSETS WITH
HICKEY OR CONDUIT BENDING MACHINE. DO NOT INSTALL CRUSHED OR
DEFORMED CONDUIT. AVOID TRAPPED CONDUITS. PREVENT PLASTER,
DIRT, OR TRASH FROM LODGING IN CONDUIT, BOXES, FITTINGS, AND
EQUIPMENT DURING CONSTRUCTION. FREE CLOGGED CONDUIT OF
OBSTRUCTIONS.
23. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE
RESISTANCE RATED WALLS, FLOORS, OR CEILINGS SHALL BE SEALED
WITH APPROVED FIRESTOPPED MATERIALS.
24. JUNCTION AND PULL BOXES SHALL CONFORM TO UL 50, HOT-DIP, ZINC
COATED, IF SHEET STEEL.
25. ALL INDOOR CONDUIT SHALL BE "EMT" CONFORMING TO UL 797/ANSI C80.2
AND FITTINGS CONFORMING TO UL 514B OR RACEWAY INSTALLED IN
ACCORDANCE WITH NEC. ALL UNDERGROUND CONDUITS SHALL BE PVC
SCHEDULE 40 BURIED AT A MINIMUM OF 24" BELOW FINISH GRADE OR
FLOOR. PROVIDE RGSC FOR ALL ELBOWS AND EXPOSED CONDUITS.
26. ALL ELECTRICAL EQUIPMENT SHALL BE NEW, UL LISTED AND APPROVED
FOR INTENDED USE.
27. VOICE AND DATA OUTLETS AND CABLING WILL BE PROVIDED BY OTHERS.
28. ALL EXPOSED CONDUIT SHALL BE INSTALLED AT LEAST 6" OFF THE FLOOR
AND 1" AWAY FROM THE WALL TO FACILITATE CLEANING.
29. PROVIDE PULL ROPES IN ALL EMPTY CONDUITS. PULL ROPES SHALL BE
PLASTIC HAVING MINIMUM 200 POUND TENSILE STRENGTH. LEAVE
MINIMUM OF 12 INCHES OF SLACK AT EACH END OF EMPTY CONDUITS.
30. ALL ELECTRICAL WORK AND MATERIALS SHALL BE PROVIDED (FURNISHED
AND INSTALLED) BY THE CONTRACTOR UNLESS INDICATED OTHERWISE.
31. ALL ELECTRICAL EQUIPMENT SHALL BE NEW (OBTAINED WRITTEN
APPROVAL FROM OWNER FOR REUSING EXISTING EQUIPMENT AND
CONDUIT), UL LISTED AND APPROVED FOR INTENDED USE.
OCCUPANCY SENSOR - WALL MOUNTED
CONSTRUCTION DOCUMENTS NOTES:
C405.6.4 COMPLETION REQUIREMENTS.
C405.6.4.1 DRAWINGS.
CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30 DAYS AFTER THE DATE OF SYSTEM
ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING
OWNER, INCLUDING:
1.A SINGLE-LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND
2.FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION.
C405.6.4.2 MANUALS.
CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT AN OPERATING MANUAL AND MAINTENANCE MANUAL BE
PROVIDED TO THE BUILDING OWNER. THE MANUALS SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING:
1.SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT
REQUIRING MAINTENANCE.
2.OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING
MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED.
3.NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY.
C408.3.2 DOCUMENTATION REQUIREMENTS.
THE CONSTRUCTION DOCUMENTS SHALL SPECIFY THAT DOCUMENTS CERTIFYING THAT THE INSTALLED
LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF SECTION C405 ARE TO BE PROVIDED
TO THE BUILDING OWNER WITHIN 90 DAYS FROM THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY.
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
G19-0004-001
04/01/2019
www.LivestoneConsulting.com
Irving Ho, PE
PE 85232
PROJECT
XXXXX
XXXXX, FL 33XXX
NEW CONSTRUCTION
OWNER
L1302130000320
L1302130000317
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
E1.0
SYMBOL LEGEND
& GENERAL
NOTES
FEET
SCALE: 3/16" = 1'-0"
0 1 2 4 8 106
1
LIGHTING PLAN
GENERAL NOTES:
1. ALL PENETRATIONS IN THE RATED WALLS AND CEILINGS SHALL BE SEALED WITH A MATERIAL
CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GAS. THE SEALANT SHALL
HAVE A T-RATING OF ONE HOUR.
2. ALL PIPING, CONDUIT, AND OUTLET BOXES IN THE RATED WALLS OR CEILING SHALL BE
CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.
3. ALL TOGGLE SWITCHES SHALL BE WALL MOUNTED AT 48" A.F.F TO CENTER.
4. COORDINATE WITH OWNER IN-FIELD FOR ALL FINAL LOCATIONS OF TOGGLE SWITCH
CONTROLS PRIOR TO ROUGH-IN.
5. ALL EXIT SIGNS SHALL BE INSTALLED COMPLETE WITH ALL INSTALLATION AND HANGING
ACCESSORIES TO PROVIDE AN UNOBSTRUCTED VIEW OF EACH SIGN FACE AS REQUIRED.
MOUNT SIGNS AT MAXIMUM +8'-0" AFF IN HIGH CEILING AREA. SIGNS SHALL BE ADJUSTED AS
NECESSARY WITHOUT ADDITIONAL COST TO THE OWNER.
6. PROVIDE EACH LIGHTING FIXTURE COMPLETE WITH FRAMES AND ALL OTHER INSTALLATION
AND HANGING HARDWARE AS REQUIRED FOR A COMPLETE AND FINISHED INSTALLATION AT
EACH FIXTURE LOCATION.
7. ALL LIGHTING FIXTURES SHALL BEAR THE UL LABELED.
8. COORDINATE ALL LIGHTING FIXTURE LOCATIONS, FINISHES, VOLTAGE AND CEILING TYPES
WITH ARCHITECT PRIOR TO ORDERING FIXTURES.
9. CONNECT EMERGENCY AND EXIT SIGNS AHEAD OF LOCAL TOGGLE SWITCHES.
10. BRANCH CIRCUITS MAY BE CONSOLIDATED INTO A SINGLE HOMERUN WITH MAXIMUM 3-120V
BRANCH CIRCUITS PER CONDUIT PRIOR TO ENTERING PANELBOARD.
11. DO NOT CONNECT EXIT SIGNS AND EMERGENCY LIGHTING UNITS ON ONE DEDICATED
CIRCUIT. CONNECT FIXTURES TO CIRCUIT NUMBERS AS INDICATED ON FLOOR PLAN.
FEET
SCALE: 3/16" = 1'-0"
0 1 2 4 8 106
2
POWER PLAN
OPEN OFFICE/
CLASSROOM TRAINING
201
STORAGE AREA
203
OPEN OFFICE/
CLASSROOM TRAINING
201
MECHANICAL ROOM
200
STORAGE AREA
202
STORAGE AREA
203
STORAGE AREA
202
MECHANICAL ROOM
200
A-8
A-2
A-2
OS
OS
OS
OS
TO STORAGE
AREA
TO FIRST
FLOOR
PANEL "A"
FIXTURE "XY" (TYPICAL)
FIXTURE "D" (TYPICAL)
FIXTURE "C" (TYPICAL)
REMOTE HEAD (TYPICAL)
A-1
A-1
A-1
A-1
A-4
A-4
A-4
A-6
A-6A-6
CU-1
A-31,35
AHU-1
A-23,25
NF
NF
CU-2
A-37,39NF
AHU-2
NF
A-27,29
1. PROVIDE MINIMUM CLEARANCE OF 3'-0" IN FRONT OF DISCONNECT SWITCH. SEE ELECTRICAL
SCHEDULE FOR MECHANICAL EQUIPMENT ON THIS SHEET FOR BRANCH CIRCUIT CONDUCTORS
AND CONDUIT AND ADDITIONAL INFORMATION. SEE PANEL SCHEDULE "A" FOR CIRCUIT NUMBERS
(TYPICAL FOR ALL AHUs AND CUs).
#
1
1
11
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
G19-0004-001
04/01/2019
www.LivestoneConsulting.com
Irving Ho, PE
PE 85232
PROJECT
XXXXX
XXXXX, FL 33XXX
NEW CONSTRUCTION
OWNER
L1302130000320
L1302130000317
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
E2.0
LIGHTING
PLAN
XFMR
PANEL
"B"
MAIN
DISC.
SWITCH
ELECTRICAL ROOMEXTERIOR
7
1
FINSIH GRADE
5
42
7
3
1. UTILITY PAD MOUNTED TRANSFORMER, 120/240V, 1Ø.
2. PROVIDE SERVICE ENTRANCE CONDUCTORS, 3#4/0 CU IN 2 1/2"C.
3. PROVIDE SELF-CONTAINED METER PER POWER COMPANY STANDARDS. EQUIPMENT SHALL BE
APPROVED BY POWER COMPANY PRIOR TO PURCHASE AND INSTALLATION. CONTRACTOR IS
RESPONSIBLE FOR ELECTRICAL COORDINATION WITH UTILITY COMPANY.
4. PROVIDE SERVICE GROUNDING ELECTRODE SYSTEM. #2 SERVICE GROUNDING ELECTRODE
CONDUCTOR.
5. PROVIDE MAIN DISCONNECT SWITCH, 120/240V, 1Ø, 225A ENCLOSED BREAKER.
6. SURGE PROTECTIVE DEVICE, 120/240V, 1Ø. PQ PROTECTION, MODEL# PQM200 OR EQUAL.
7. PROVIDE 3#4/0 CU & 1#4 CU IN 2 1/2"C.
8. PANELBOARD, REFER TO PANEL SCHEDULE FOR DETAILS.
#
SPD
6
8
NTS
ELECTRICAL ONE-LINE DIAGRAM
NTS
SERVICE GROUNDING ELECTRODE SYSTEM DETAIL
MAIN SERVICE
EQUIPMENT
GROUNDING BUS
SERVICE ENTRANCE
CONDUIT
GROUNDING
CONDUCTOR
EXISITNG 2-3/4" DIA. X 10'
LONG COPPER CLAD
GROUND ROD, NOT LESS
THAN 24" BELOW GRADE
(TYPICAL)
EXOTHERMIC CADWELD
PROCESS
MAIN SERVICE
EQUIPMENT
NEUTRAL BUS
BONDING JUMPER
NOTES:
COPPER CONDUCTOR TO
STRUCTURAL STEEL/
METALLIC WATER PIPE
SERVICE EQUIPMENT
COPPER CONDUCTOR TO
GROUNDING BUS BAR
NOTE: RESISTANCE TO
GROUND ROD SHALL NOT
EXCEED 25 OHMS
1. DO NOT CONNECT THE BUILDING
GROUNDING ELECTRODE SYSTEM WITH
THE SERVICE TRANSFORMER GROUNDING
SYSTEM.
2. A WRITTEN RECORD OF THE GROUND
PERFORMANCE TEST RESULTS SHALL BE
MADE AVAILABLE UPON REQUEST TO THE
AUTHORITY.
FBC ENERGY CONSERVATION C405.7.3 VOLTAGE DROP
THE FEEDERS AND BRANCH CIRCUITS HAVE BEEN DESIGNED TO COMPLY WITH
THE VOLTAGE DROP ALLOWANCES SET FORTH IN THE 2014 FLORIDA BUILDING
CODE-ENERGY CONSERVATION.
1. WHEN A GFCI CIRCUIT BREAKER IS UTILIZED WITHIN CIRCUITS THAT ARE GROUPED TOGETHER IN
A SINGLE HOMERUN, A SEPARATE NEUTRAL CONDUCTOR SHALL BE RUN FOR EACH PHASE
CONDUCTOR.
2. WHEN CIRCUITS ON PLANS SHOW GROUPED WITHIN A SINGLE HOMERUN, THE CIRCUIT BREAKERS
THAT FEED THOSE CIRCUITS SHALL BE PROVIDED WITH ONE OF THE FOLLOWING PER NEC 210.4:
A SEPARATE NEUTRAL FOR EACH CIRCUIT; A SINGLE HANDLE TIE TO SIMULTANEOUSLY
DISCONNECT THE GROUPED CIRCUITS; OR A 2-POLE OR 3-POLE CIRCUIT BREAKER AS REQUIRED.
THIS DOES NOT APPLY TO DEDICATED 2-POLE AND 3-POLE CIRCUITS.
PANEL SCHEDULE GENERAL NOTES
SEE PANEL
SCHEDULE
REFER TO MECHANICAL SCHEDULE
MECH UNIT
1. ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT, CIRCUIT BREAKER, ASSOCIATED
WIRING AND CONDUIT WITH MECHANICAL SHOP DRAWINGS PRIOR TO ORDERING ELECTRICAL
EQUIPMENT. IF SIZE(S) OF ELECTRICAL EQUIPMENT REQUIRED DIFFERS FROM WHAT IS INDICATED
ON ELECTRICAL PLANS, NOTIFY ELECTRICAL ENGINEER OF CHANGES.
2. DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACCESS PANELS.
3. PROVIDE A 3/4" EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS (I.E. WALLS, UNDER SLAB)
FOR CONTROL WIRING. COORDINATE WITH MECHANICAL PLANS.
4. ELECTRICAL DESIGN IS BASED ON THE MANUFACTURER AND MODEL NUMBER LISTED ON THE
MECHANICAL PLANS. IF THERE IS AN EQUAL OR ALTERNATE MANUFACTURER PROVIDED, THE
MECHANICAL/GENERAL CONTRACTOR SHALL BEAR ANY AND ALL ADDITIONAL COST RELATED TO
THE ELECTRICAL CHANGES ASSOCIATED WITH SUCH SUBSTITUTIONS.
5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL STARTERS FURNISHED BY MECHANICAL
CONTRACTOR UNLESS STARTERS ARE SPECIFICALLY NOTED ON MECHANICAL PLANS TO BE
FACTORY INSTALLED (SEE NOTE 4). MAKE ALL FINAL CONNECTIONS.
NOTES
NTS
HVAC WIRING DETAILS
SENSOR
LINE-VOLTAGE
LOAD
GRD
NEUT
HOT BLK
LOAD
RED
NTS
NIGHT/EMER/EXIT
LIGHTS
SINGLE SWITCH
(3-WAY SWITCH,
IF SHOWN)
LINE-VOLTAGE WALL OR CLG. OCCUPANCY SENSOR
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
G19-0004-001
04/01/2019
www.LivestoneConsulting.com
Irving Ho, PE
PE 85232
PROJECT
XXXXX
XXXXX, FL 33XXX
NEW CONSTRUCTION
OWNER
L1302130000320
L1302130000317
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
E3.0
POWER
PLAN
MECHANICAL ROOM
OPEN OFFICE/
CLASSROOM TRAINING
STORAGE AREA
STORAGE AREA
PLUMBING LEGEND
PR
ELIM
IN
AR
Y, N
OT
F
OR
C
ON
ST
RU
CT
IO
N
P1.0
PLUMBING
FLOOR PLAN
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
NEW CONSTRUCTION
OWNER
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
G19-0004-001
04/01/2019
PROJECT
XXXXX
XXXXX, FL 33XXX
PLUMBING FIXTURE SCHEDULE
PR
ELIM
IN
AR
Y, N
OT
F
OR
C
ON
ST
RU
CT
IO
N
P2.0
PLUMBING
C 2019 LIVESTONE CONSULTING INC.
SEAL
SHEET NUMBER
REVISIONS
PROJECT NUMBER
SHEET TITLE
DESCRIPTIONNO. DATE
www.LivestoneConsulting.com
NEW CONSTRUCTION
OWNER
2901 West Busch Blvd. Ste. 204
Tampa, FL 33618
XXXXX
XXXXX, FL 33XXX
G19-0004-001
04/01/2019
PROJECT
XXXXX
XXXXX, FL 33XXX
RISERS, NOTES
AND DETAILS