india default parameters
TRANSCRIPT
-
8/8/2019 India Default Parameters
1/22
C Parameter name Unit Rec. Def Mumbai aharashtr
No of Preferred Cells (NPC)
MS distance behaviour (DISB)
HO preference order interference DL (HDL)
HO preference order interference UL (HUL)
Answer to paging call on FACCH (EPF)Call re-establishment on FACCH (ERF)
Emergency call on FACCH (EEF)
Ordinary call on FACCH (EOF)
TCH rate internal HO (HRI)
Lower limit for FR TCH resources (HRL)
Upper limit for FR TCH resources (HRU)
Variable DL Step Use, S9 (VDLS)
Territory Update Guard Time GPRS, S9 (GTUGT)
-
8/8/2019 India Default Parameters
2/22
Gujarat Orissa Bihar
3
255
Inter-cell
Inter-cell
NoNo
No
No
Best candidate
30
70
No
5
-
8/8/2019 India Default Parameters
3/22
Parameter name
Cell Access Parameters
Cell Barred (BAR)
Call Reestablishment Allowed (RE)
Emergency Call Restricted (EC)Power Offset (PO)
GPRS enabled, S9 (GENA)
plmn permitted
Cell Reselect Hysteresis (HYS)
Ms Tx Pwr Max Cch (TXP1)
Ms Tx Pwr Max Cch 1x00 (TXP2)
Rx Lev Access Min (RXP)
Radio Link Timeout (RLT)
Number of Blocks for AGCH (AG)
Number of MultiFrames (MFR)Timer Periodic Update MS (PER)
Allow IMSI Attach/Detach (ATT)
Queueing Parameters
Max Queue Length (MQL)
Time Limit Call (TLC)
Time Limit Handover (TLH)
MS Priority Used (MPU)
Queue Priority Used (QPU)
Queueing Priority Call (QPC)
Queueing Priority Handover (QPH)Queue Priority Non-urgent HO (QPN)
Diversity Used (RDIV)
DTX Mode (DTX)
BTS Measure Average (BMA)
MS Tx Power Max GSM (PMAX1)
MS Tx Power Max GSM 1800/1900 (PMAX2)
MS Tx Power Min (PMIN)
Max Number Retransmission (RET)
Max Number of Repetition (NY1)Number of Slot Spread Trans (SLO)
SMS CB used (CB)
BTS Load Threshold (BLT)
MS Max Distance in Call Setup (DMAX)
TCH Rate Intra Cell HO (TRIH)
Early Sending (ESI)
TRX Priority in TCH Alloc. (TRP)
Prefer BCCH TRXs in GPRS..., S9 (BFG)
Double BA-Lists Option
Idle State BCCH Allocation List Use
Identification of BCCH Frequency List (IDLE)
-
8/8/2019 India Default Parameters
4/22
BCCH Allocation Usage for Active MS (ACT)
C2 Reselection Option
Cell Reselection Param. Index (PI)
Cell Bar Qualify (QUA)
Cell Reselect Offset (REO)Temporary Offset (TEO)
Penalty Time (PET)
Half Rate Option
Lower Limit for FR TCH Res. (FRL)
Upper Limit for FR TCH Res. (FRU)
Dual Band Option
Dual Band (DBC)
Multi Band Cell Reporting (MBR)
Directed Retry / Intelligent Directed Retry Option
Directed Retry used (DR)
Intelligent DR used (IDR)
DR method (DMR)
Max Time Limit DR (MADR)
Min Time Limit DR (MIDR)
Directed Retry Threshold
FACCH Call Setup Option
New Establ. Causes Support (NECI)
TRX Parameters
Optimum RX level uplink (BLEV)
Optimum RX level downlink, S9 (LEVD)
-
8/8/2019 India Default Parameters
5/22
Recommended setting
No
No0
Yes
= Only allocated NCC's for that PLMN
6.0 dB
33.0 dBm for 900NW's
30.0 dBm for 1800NW's
To be decided after trial
20.0 SACCH
2
44.0 Hours
Yes
0.5
5.0 sec
5.0 sec
Yes
Yes
9
911
On
Shall
0 SACCH
33.0 dBm (GSM900)
30.0 dBm (GSM1800)
0.0 dBm
4
514
Yes
70
255
No constraints
Allowed
From BCCH TRX
No
BCCHs of adjacent cells
BA list used
Yes+MAX WAIT TIME FOR RE-ESTABREQ =15secs in all MSC's
-
8/8/2019 India Default Parameters
6/22
BCCHs of adjacent cells
0
0
00.0 dBm
20.0 sec
0.1
0.3
No
1
Yes
No
Yes
6 sec
2 sec
-80 dBm
No
Not used
Not used
-
8/8/2019 India Default Parameters
7/22
-
8/8/2019 India Default Parameters
8/22
-
8/8/2019 India Default Parameters
9/22
Parameter name Recommended setting Mumbai
POC General
Power Control Enabled (PENA) Yes Yes
Maximum Transmit Power (PMAX) (max- 0.0) dB (max- 0.0) dB
Minimum Transmit Power (PMIN) (max- 30.0) dB (max- 30.0) dB
Power Increasing Step Size (INC) 4.0 dB 6.0 dBPower Reducing Step Size (RED) 2.0 dB 2.0 dB
Power Control Interval (INT) 2.0 sec 2.0 sec
Power Decr Limit Band 0 (PD0) No change 19.0 dB
Power Decr Limit Band 1 (PD1) No change 19.0 dB
Power Decr Limit Band 2 (PD2) No change 19.0 dB
Power Decr Qual Factor (PDF) 1 1
ALA Enabled (AENA) No No
Power Limit ALA (ALIM) 10.0 dBm 10.0 dBm
Min Int between ALA (AMIN) 10.0 sec 10.0 sec
POC Averaging
PC Averaging Lev DL Wind Size (LDS) 4 4
PC Averaging Lev DL Weighting (LDW) 1 1
PC Averaging Lev UL Wind Size (LUS) 4 4
PC Averaging Lev UL Weighting (LUW) 2 2
PC Averaging Qual DL Wind Size (QDS 1 4
PC Averaging Qual DL Weighting (QD 1 1
PC Averaging Qual UL Wind Size (QUS 1 4
PC Averaging Qual UL Weighting (QU 2 2
POC ThresholdsPC Lower Thresholds Level DL Rx (LD -85.0 dBm -78.0 dBm
PC Lower Thresholds Level DL Px (LDP 1 1
PC Lower Thresholds Level DL Nx (LD 1 2
PC Upper Thresholds Level DL Rx (UD -70.0 dBm -70.0 dBm
PC Upper Thresholds Level DL Px (UD 1 1
PC Upper Thresholds Level DL Nx (UD 1 2
PC Lower Thresholds Level UL Rx (LUR -85.0 dBm -78.0 dBm
PC Lower Thresholds Level UL Px (LUP 1 1
PC Lower Thresholds Level UL Nx (LU 1 2
PC Upper Thresholds Level UL Rx (UU -70.0 dBm -70.0 dBmPC Upper Thresholds Level UL Px (UUP 1 1
PC Upper Thresholds Level UL Nx (UU 1 2
PC Lower Thresholds Qual DL Rx (LDR
-
8/8/2019 India Default Parameters
10/22
PC Upper Thresholds Qual UL Px (UUP) 32 1
PC Upper Thresholds Qual UL Nx (UUN 32 1
PC Lower Threshold Qual 144 (LQR)
-
8/8/2019 India Default Parameters
11/22
Maharashtra Gujarat Orissa Bihar
Yes Yes Yes Yes
(max- 0.0) dB (max- 0.0) dB (max- 0.0) dB (max- 0.0) dB
(max- 30.0) dB (max- 30.0) dB (max- 30.0) dB (max- 30.0) dB
4.0 dB 4.0 dB 4.0 dB 6.0 dB2.0 dB 2.0 dB 2.0 dB 2.0 dB
2.0 sec 2.0 sec 2.0 sec 2.0 sec
6.0 dB 12.0 dB 19.0 dB 19.0 dB
5.0 dB 10.0 dB 19.0 dB 19.0 dB
3.0 dB 6.0 dB 19.0 dB 19.0 dB
1 1 1 2
No No No No
6.0 dBm 6.0 dBm 6.0 dBm 6.0 dBm
10.0 sec 10.0 sec 10.0 sec 10.0 sec
4 4 4 4
1 1 1 1
4 4 4 4
1 2 1 2
1 4 1 4
1 1 1 1
1 4 1 4
1 2 1 2
-82.0 dBm -85.0 dBm -85.0 dBm -85.0 dBm
1 1 1 1
1 2 1 1
-74.0 dBm -70.0 dBm -70.0 dBm -70.0 dBm
1 1 1 1
1 2 1 1
-85.0 dBm -90.0 dBm -85.0 dBm -85.0 dBm
1 1 1 1
1 2 1 1
-75.0 dBm -75.0 dBm -70.0 dBm -70.0 dBm1 1 1 1
1 2 1 1
-
8/8/2019 India Default Parameters
12/22
1 1 32 32
1 1 32 32
-
8/8/2019 India Default Parameters
13/22
Parameter name Recommended setting
HO General
Min Int Between HO Req (MIH) 5.0 sec
Min Int Between Unsucc HO Att (MIU) 3.0 sec
HO Period Umbrella (HPU) 6.0 SACCH
HO Period PBDGT (HPP) 6.0 SACCHEnable Fast Ave Call Setup (EFA) No
Enable Fast Ave HO (EFH) No
Enable Fast Ave PC (EFP) No
Power budget HO (EPB) Yes
MS distance process (EMS) No
SDCCH HO (ESD) No
Umbrella HO (EUM) No
Intra Cell HO intf DL (EIH) Yes
Intra Cell HO intf UL (EIC) Yes
HO Averaging
HO Averaging Lev DL Wind Size (LDWS) 6
HO Averaging Lev DL Weighting (LDW) 1
HO Averaging Lev UL Wind Size (LUWS) 6
HO Averaging Lev UL Weighting (LUW) 2
HO Averaging Qual DL Wind Size (QDWS) 1
HO Averaging Qual DL Weighting (QDW) 1
HO Averaging Qual UL Wind Size (QUWS) 1
HO Averaging Qual UL Weighting (QUW) 2
HO ThresholdsHO Thresholds Lev DL Rx (LDR) -110/-90 dBm
HO Thresholds Lev DL Px (LDP) 1
HO Thresholds Lev DL Nx (LDN) 1
HO Thresholds Lev UL Rx (LUR) -110/-96 dBm
HO Thresholds Lev UL Px (LUP) 1
HO Thresholds Lev UL Nx (LUN) 1
HO Thresholds Qual DL Rx (QDR)
-
8/8/2019 India Default Parameters
14/22
All Adjacent Cells Averaged (AAC) No
MS Distance Parameters
MS Dist Averag Par Wind Size (MSWS) 10
MS Dist Averag Thresholds Par (MSR) 63
Px (MSP) 1Nx (MSN) 1
Chained Cells in Rapid Field Drop Option
Count of Successuive Rapid Drop Thresholds (CNT 0
Threshold Level Uplink for Rapid Field Drop (RPD) -110.0 dBm
MS Speed Option
Threshold Nx (STN) 6
Threshold Px (STP) 3
Averaging (MSA) 4
Lower Speed Limit (LSL) Verifying not made
Upper Speed Limit (USL) Verifying not made
C/I Based HO Candidate Evaluation Option
C/I Estimation Method Not used
Enable Enhanced Rapid Field Drop (ERFD) No
Deep Dropping Edge Monitor Window (ERMW) 1 SACCH frames
Modified Averaging Window (ERAW) 2
Modified Number of Zero Results (ERZ) 1Enhanced Rapid Field Drop Duration (ERD) 9 sec
Adjacent Cell Parameters
Synchronization (SYNC) No
HO Priority Level (PRI) 3
Rx Level Minimum Cell (SL) -100 dBm
HO Margin Power Budget (PMGR) 6
HO Margin Level (LMGR) 3
HO Margin Quality (QMGR) 0
HO Level Umbrella (AUCL) -47 dBm
Enable HO Margin for Qual and Lev Yes
HO Load Factor (OF) 1
Optimisation of MS Power Level (POPT) Non Optimised
Chained Adjacent Cell (CHAIN) No
Threshold Target Level (TRHO) Not Used dBm
Fast Moving Threshold (FMT) 0
Adjacent Cell Layer (ACL) Not used
-
8/8/2019 India Default Parameters
15/22
Mumbai Maharashtra Gujarat Orissa Bihar
5.0 sec 5.0 sec 5.0 sec 5.0 sec 5.0 sec
3.0 sec 3.0 sec 3.0 sec 3.0 sec 3.0 sec
6.0 SACCH 6.0 SACCH 6.0 SACCH 6.0 SACCH 6.0 SACCH
6.0 SACCH 6.0 SACCH 6.0 SACCH 6.0 SACCH 6.0 SACCHNo No No No No
No No No No No
No No No No No
Yes Yes Yes Yes Y
No No No No No
No No No No No
No No No No No
Yes No Yes Yes Y
Yes No Yes Yes Ye
4 6 4 4 4
1 1 1 1 1
4 6 4 4 4
2 1 2 1 2
3 1 3 1 1
1 1 1 1 1
3 1 3 1 1
2 1 2 1 2
-110.0 dBm -110.0 dBm -90.0 dBm -95.0 dBm -110.0 dBm
3 1 3 1 3
4 1 4 1 4
-110.0 dBm -110.0 dBm -95.0 dBm -98.0 dBm -110.0 dBm
3 1 3 1 3
4 1 4 1 4
-
8/8/2019 India Default Parameters
16/22
No No No No No
10 10 10 10 10
63 63 63 63 63
2 10 2 1 12 16 2 1 1
0 0 0 0 0
-110.0 dBm -110.0 dBm -110.0 dBm -110.0 dBm -110.0 dBm
6 6 6 6 6
3 3 3 3 3
4 4 4 4 4
Verifying not madeVerifying not madeVerifying not madeVerifying not madeVerifying not made
erifying not made erifying not made erifying not made erifying not made erifying not made
Not used Not used Not used Not used Not used
No No No No No
2 SACCH frames 2 SACCH frames 2 SACCH frames 2 SACCH frames 2 SACCH frames
2 2 2 2 2
1 1 1 1 110 sec 10 sec 10 sec 10 sec 10 sec
No No No No No
3 3 3 3 3
-96 dBm -105 dBm -100 dBm -98 dBm -98 dBm
6 4 6 6 6
3 3 3 3 3
0 0 0 0 0
-47 dBm -47 dBm -47 dBm -47 dBm -47 dBm
Yes Yes Yes Yes Yes
1 1 1 1 1
Non Optimised Non Optimised Non Optimised Non Optimised Non Optimised
No No No No No
Not Used dBm Not Used dBm Not Used dBm Not Used dBm Not Used dBm
0 0 0 0 0
Not used Not used Not used Not used Not used
-
8/8/2019 India Default Parameters
17/22
-
8/8/2019 India Default Parameters
18/22
-
8/8/2019 India Default Parameters
19/22
Parameter name Recommended setting
Cell Access Parameters
Cell Barred (BAR) No
Call Reestablishment Allowed (RE)
Emergency Call Restricted (EC) NoPower Offset (PO) 0
GPRS enabled, S9 (GENA) Yes
plmn permitted = Only allocated NCC's for that PLMN
Cell Reselect Hysteresis (HYS) 6.0 dB
Ms Tx Pwr Max Cch (TXP1) 33.0 dBm for 900NW's
Ms Tx Pwr Max Cch 1x00 (TXP2) 30.0 dBm for 1800NW's
Rx Lev Access Min (RXP) To be decided after trial
Radio Link Timeout (RLT) 20.0 SACCH
Number of Blocks for AGCH (AG) 2
Number of MultiFrames (MFR) 4
Timer Periodic Update MS (PER) 4.0 HoursAllow IMSI Attach/Detach (ATT) Yes
Queueing Parameters
Max Queue Length (MQL) 0.5
Time Limit Call (TLC) 5.0 sec
Time Limit Handover (TLH) 5.0 sec
MS Priority Used (MPU) Yes
Queue Priority Used (QPU) Yes
Queueing Priority Call (QPC) 9
Queueing Priority Handover (QPH) 9
Queue Priority Non-urgent HO (QPN) 11
Diversity Used (RDIV) On
DTX Mode (DTX) Shall
BTS Measure Average (BMA) 0 SACCH
MS Tx Power Max GSM (PMAX1) 33.0 dBm (GSM900)
MS Tx Power Max GSM 1800/1900 (PMAX2) 30.0 dBm (GSM1800)
MS Tx Power Min (PMIN) 0.0 dBm
Max Number Retransmission (RET) 4
Max Number of Repetition (NY1) 5
Number of Slot Spread Trans (SLO) 14
SMS CB used (CB) Yes
BTS Load Threshold (BLT) 70
MS Max Distance in Call Setup (DMAX) 255
TCH Rate Intra Cell HO (TRIH) No constraints
Early Sending (ESI) Allowed
TRX Priority in TCH Alloc. (TRP) From BCCH TRX
Prefer BCCH TRXs in GPRS..., S9 (BFG) No
Yes+MAX WAIT TIME FOR RE-ESTABREQ =15secs in all MSC's
-
8/8/2019 India Default Parameters
20/22
Double BA-Lists Option
Idle State BCCH Allocation List Use BCCHs of adjacent cells
Identification of BCCH Frequency List (IDLE) BA list used
BCCH Allocation Usage for Active MS (ACT) BCCHs of adjacent cells
C2 Reselection Option
Cell Reselection Param. Index (PI) 0
Cell Bar Qualify (QUA) 0
Cell Reselect Offset (REO) 0
Temporary Offset (TEO) 0.0 dBm
Penalty Time (PET) 20.0 sec
Half Rate Option
Lower Limit for FR TCH Res. (FRL) 0.1
Upper Limit for FR TCH Res. (FRU) 0.3
Dual Band Option
Dual Band (DBC) No
Multi Band Cell Reporting (MBR) 1
Directed Retry / Intelligent Directed Retry Option
Directed Retry used (DR) Yes
Intelligent DR used (IDR) No
DR method (DMR) Yes
Max Time Limit DR (MADR) 6 sec
Min Time Limit DR (MIDR) 2 sec
Directed Retry Threshold -80 dBm
FACCH Call Setup Option
New Establ. Causes Support (NECI) No
TRX Parameters
Optimum RX level uplink (BLEV) Not used
Optimum RX level downlink, S9 (LEVD) Not used
-
8/8/2019 India Default Parameters
21/22
-
8/8/2019 India Default Parameters
22/22