indigenous software for quantification of autonomic tone

22
Indigenous software for quantification of autonomic tone Prof. K K Deepak MD, PhD, MNAMS Professor of Physiology [email protected] All India Institute of Medical Sciences New Delhi 110029 India

Upload: kennan-riddle

Post on 31-Dec-2015

13 views

Category:

Documents


1 download

DESCRIPTION

Indigenous software for quantification of autonomic tone. Prof. K K Deepak MD, PhD, MNAMS Professor of Physiology [email protected]. All India Institute of Medical Sciences New Delhi  110029   India. ECG. HRV pattern. Autonomic Control of Function of Heart. PNS. High freq. Aff. Nvs. - PowerPoint PPT Presentation

TRANSCRIPT

Indigenous software for quantification of autonomic

tone

Prof. K K Deepak     MD, PhD, MNAMS  Professor of Physiology [email protected]

All India Institute of Medical SciencesNew Delhi  110029   India

Aut

onom

ic c

ontr

olle

r

PNS

SNS

High freq.

Low freq.

Aff. Nvs.

ECG

Autonomic Control of Function of Heart

HRV pattern

Respiration

Blood Pressure

Cardiac Output

Renin-Angioten.

Thermoregul.

Others inputs Aut

onom

ic c

ontr

olle

r

PNS

SNS

High freq.

Low freq.

Aff. Nvs.

ECG

Autonomic Control of Function of Heart

HRV pattern

• Cardiovascular pathophysiology

• Myocardial Infarction

• Diabetic neuropathy

• Estimation of vagal tone

• Neurological disorders

•Migraine

Applied aspect of Cardiac tone (HRV)Applied aspect of Cardiac tone (HRV)

•MSA

• Assessment of neonatal ANS

• Hypertension

• Cardiac Transplant Rejection

• End organ failure

• Hypertension

• Hypertensive Pregnancy Disorders

Applied aspect of vascular tone (BPV)Applied aspect of vascular tone (BPV)

• Risk factor for stroke / SCD / SIDS

• Prognosis in CHF

Autonomic Tone (HRV) in health and disease

Healthy Healthy

Heart Attack Heart transplant

Indigenously Developed HRV Software for the Quantification of Autonomic

ToneObjectives

Software development for measurement of Heart Rate Variability (HRV_Soft) and Blood Pressure Variability (BPV_Soft)

Offline Data Analysis

Online Data Acquisition

Done

Done

Done

Development & Acquisition Tools Used

1. National Instruments USB-6008 DAQ

2. National Instruments (NI) Labview FDS 8.0

3. NI Measurement and Automation Libraries

1) Colin BP-508 BP Monitor 2) Finapres Ohmeda 2300 BP Monitor3) DAS port (Nevrokard)4) Analog ECG from any source

Patient

DAQ Module

(USB Based)

Analysis & Storage

Signal Source Flow Diagram

Blood Pressure

ECG

HRV_Soft

BPV_Soft

Main Panel of Indigenously Developed Software (HRV_Soft)

Heart Rate Variability

Validation of our HRV_Soft & studies carried out

• We acquired the ECG and BP Signal from the Nevrokard DAS port and FINAPRES simultaneously on our Software and Nevrokard Software.

• We compared the Time Domain, Frequency Domain & Non Linear Parameters

• The results were found to be Statistically comparable

Testing Model 1

AnalysisAnalysis

Analog Signal Acquisition

Nevrokard

Digitization Digitization

Analog Signal Acquisition

Single patient source (ECG)

HRV_Soft

Time Domain Parameters

Mean

894.17 894.32

0.00

200.00

400.00

600.00

800.00

1000.00

Nevrokard Our Software

Varaince

2196.30 2178.49

0.00

1000.00

2000.00

3000.00

Nevrokard Our Software

NN50 Count

25.39

30.82

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

SDNN

42.19 42.15

0.00

10.00

20.00

30.00

40.00

50.00

Our SoftwareNevrokard

RMSDD

36.85 36.58

0.00

10.00

20.00

30.00

40.00

50.00

Our SoftwareNevrokard

N=22

SDANN

36.86 36.63

0.00

10.00

20.00

30.00

40.00

50.00

Our SoftwareNevrokard

FREQUENCY DOMAIN PARAMETERS

LF/HF

2.00 1.98

0.00

0.50

1.00

1.50

2.00

2.50

Our SoftwareNevrokard

% VLF

37.10 38.77

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

% LF

32.76 34.46

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

%HF

30.13 29.40

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

N=22

AnalysisAnalysis

Nevrokard

Digitization & Peak detection by our software

BPV_SoftHRV_Soft

Testing Model 2

Analog Signal Acquisition ( our software)

Patient ECG

Pearson Correlation Test of HRV parameters obtained from 45 subjects as measured from HRV soft and Neurokard

Varaince

2196.30 2178.49

0.00

1000.00

2000.00

3000.00

Nevrokard Our Software

NN50 Count

25.39

30.82

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

SDNN

42.19 42.15

0.00

10.00

20.00

30.00

40.00

50.00

Our SoftwareNevrokard

RMSDD

36.85 36.58

0.00

10.00

20.00

30.00

40.00

50.00

Our SoftwareNevrokard

LF/HF

2.00 1.98

0.00

0.50

1.00

1.50

2.00

2.50

Our SoftwareNevrokard

% VLF

37.10 38.77

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

% LF

32.76 34.46

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

%HF

30.13 29.40

0.00

10.00

20.00

30.00

40.00

Our SoftwareNevrokard

Statistical Parameters r2 rp Value(p<0.05)

Range 0.9995 1.000 0.000

Mean 0.9999 1.000 0.000

Median 0.8862 0.944 0.000

Variance 1.0000 1.000 0.000

VLF% 0.8597 0.928 0.000

LF% 0.9445 0.975 0.000

HF% 0.8855 0.941 0.000

LF(nu) 0.8455 0.920 0.000

HF(nu) 0.8997 0.949 0.000

SD1 1.0000 1.000 0.000

SD2 0.8649 0.959 0.000

SD1/SD2 0.8394 0.957 0.000

One more feature has been developed which can trace the path of Non Linear behavior. This actually analyses the phases of development of Poincare plot.

What is being delivered ?

Unique features of our software

1.Complete report generation in printable format as shown in fig below. Also all the parameter of time frequency & non-linear analysis are transferred to Excel sheet for maintaining Database

2. Additional Parameters than commercially available software. 3.Poincare tracking feature in poincare plot (Non-linear analysis) allows

user to observe point-by-point movement of the plot 4.Provision for deleting artifacts present in the ECG waveform before

performing Peak detection.

5.Robust fully automatic peak detection algorithm.

6.USB/Serial port connectivity & Easy to use Graphical User Interface.

7.Flexible & Cost Effective.

HRV-SoftBPV-Soft

Analog to Digital

Converter

Any device thatcan pick

ECG signals

Any Biological signal:

EEG/ EMG/ENG/

Resp/ EGG/ ICG

Any device thatcan record

Continuous BP

Compatibility with existing systems

General compatibility

2007

1996 2004

2002