 Human Development Consultants Ltd.

Describe and Operate 

Indirect-F

ired 

Line Heaters

Training Module

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 2/25

 

Cover PhotoC ou r te sy  of P r e ss on E N E RF LEX and Pet r o -C anada 

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 3/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

 © 2006 and 2014 HDC Human Development Consultants Ltd.

All   ri ght s   r e s e r v ed . No part of this  publication may  be copied, reproduced, stored in a computer  or retrieval system, published, distributed, or transmitted in any form or by any means whatsoever, including

without limitation by mechanical means, photo copying, recording, digital or electronic media, the Internet,or otherwise, without the express prior written permission of HDC Human Development Consultants Ltd.(HDC). HDC grants to the purchaser of a Single User License (as defined in the agreement with suchpurchaser)  a limited license to store the electronic  file(s)  on one computer  only  and to make a singlepaper  copy  of this  publication. HDC  grants  to the purchaser  of a Site License (as  defined in theagreement with such purchaser) a limited license to store the electronic file(s) on one local area network server accessible by individual users' computers at one site or location only and to make paper copies ofthis publication for a company’s employees at the same site or  location only. Each site or  location mustpurchase a separate Site License for employees at that site. HDC grants the purchaser of a CorporateLicense (as defined in the agreement with such purchaser) a limited license to store the electronic file(s) on its  intranet and on computers at company sites or  locations and to make paper copies  for any or all employees. Nothing in the foregoing restricts, amends  or  abrogates  the provisions  of the agreementbetween HDC and the purchaser of the applicable license. Any copying or  use other  than pursuant tosuch a license is illegal. For further information, please consult the applicable license agreement.

This  publication is  designed to provide general  information regarding the sub ject matter covered. Carehas  been taken to ensure the accuracy  of the information and that the instructions  contained in this publication are clear  and reflect sound practice. The user  understands  that HDC  is  not providingengineering services. The user  understands  that any  procedures  (task  steps)  that are published or referenced may  have to be modified to comply  with specific  equipment, work  conditions, company standards, company policies and practices, legislation, and user qualifications. HDC does not make any representations, guarantees, or warranties of any kind whatsoever with respect to the content hereof andthe results to be achieved by  implementing the procedures  (task steps) herein. To the maximum extentpermitted by  applicable law, in no event shall HDC  be liable for  any  damages  whatsoever  (includingwithout limitation, direct or indirect damages for personal in jury, damages to the environment, damages tobusiness property, loss of business profit, or any other pecuniary  loss). The use of the information andprocedures (task steps) herein is undertaken at the sole risk of the user.

ISBN 1-55338-040-1

Canadian Cataloguing in Publication Data 

1. Pipelines—Equipment and supplies. I. HDC Human Development Consultants.TP757.F48 2005 665.7’44 C2005-906879-5

This training kit consists of the following parts: 

Training Module and Self-Check Knowledge Check and Answer Key Blank Answer Sheet

Performance Check ExerciseJob Aid 

Published by HDC Human Development Consultants Ltd.

Published in Canada

HDC Human Development Consultants Ltd.

Website:  www.hdc.ca E-mail: [email protected] Phone: (780) 463-3909 

Augu s t , 2014  

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 4/25

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 5/25

 

Contents Training Objectives 1

1 Introduction  1

2 Heat Medium Components 7 

2.1 Heater Shell  7

2.2 Produced Gas Flow Coil  8

3  Combustion Components 12 3.1 Fuel Gas Supply  12

3.2 Fuel Gas Conditioning System  16

3.3 Burner Fuel Gas  17

3.4 Burner Assembly  21

3.5 Fire Tube Assembly  27

4 Combustion Safety Controls 28 

4.1 Hazardous / Upset Conditions that Shut Down the

Line Heater  29

4.2 Pneumatic Combustion Safety Controls  29

4.3 Microprocessor-Based Combustion Safety Controls  32

5 Site Layouts 37 

5.1 Gas Wellsites  37

5.2 Gathering System Sites  39

6 Choke Operation  40

Augu s t , 2014 Pa g e i of  ii

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 6/25

 

Augu s t , 2014 Pa g e ii of  ii

Contents (continued) 

7  Site Systems and Equipment  41 7.1 Cold-Climate Enclosure Building 41

7.2 Chemical In jection Systems  44

7.3 Downhole Heat String 44

7.4 Flow Measurement 46

7.5 Combustible Gas, Toxic Gas, and Fire Detection 48

7.6 SCADA (Supervisory Control and Data

Acquisition) System  49

7.7 Electrical Power System  51

7.8 Emergency Shutdown (ESD) Pushbuttons  52

8 Line Heater Safety 52 

8.1 Safety While Traveling to the Line Heater Site 52

8.2 Safety at the Line Heater Site 53

8.3 Safety at the Line Heater Building 57

8.4 Safety When Leaving the Line Heater Site 58

9 Operating Variables 58

10 Prepare Line Heater for Startup  59 

10.1 Investigate Line Heater Shutdown 59

10.2 Restart Line Heater  61

11 Light Line Heater Burner Manually 61

12  Self Check 66

13 Answer Key 77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 7/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Training 

Objectives 

Upon completion of this training kit, you will be able to:

Describe the purpose and importance of indirect-fired line

heaters 

Describe line heater:

components and their function

combustion safety controls 

Describe line heater site layouts 

Describe line heater site systems and equipment

Describe line heater safety 

Describe manual lighting of line heater burner 

Describe line heater operating variables and operations 

monitoring

Troubleshoot line heaters 

1 Introduction Indirect-fired line heaters are used to heat natural gas before

the gas is shipped by pipeline for processing or for distribution

to residential and industrial customers.

During shipping, processing, and distribution, the natural gas 

cools as:

heat is lost to cooler surroundings (e.g., a subsurface gas pipeline loses heat to the surrounding soil) 

the pressure of the gas is reduced

Gas cooling can cause problems downstream on the pipeline:

the formation of hydrates which can block the pipeline (see

the textbox on page 4 about hydrates and their hazards) 

hydrates formed in meters can cause inaccurate readings 

the chilling of downstream equipment:

in mechanical equipment (e.g., meters, regulators, and

valves), cold temperatures may prevent lubricatedinternal components from operating effectively 

in gas analysis instrumentation, cold temperatures may 

contribute to inaccurate sampling results 

Augu s t , 2014 Pa g e 1 of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 8/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Figure 1 —Typical Line Heater Locations in Natural Gas Processing/ Distribution

Augu s t , 2014 Pa g e 2  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 9/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Indirect-fired line heaters heat the natural gas to prevent

hazardous hydrate blockages and frozen downstream 

equipment.

Line heaters are typically installed:

at gas wellsites where the high wellhead pressure must be

reduced so that gas can flow via lower pressure piping to a

downstream gas plant. A ma jor drop in gas pressure causes 

significant cooling of the gas to the point where hydrates 

could form. Line heaters are installed at the site to heat the

gas to prevent hydrate formation.

along gas gathering system pipelines that link remote gas 

fields to gas processing plants. Gas cools as it passes 

through the pipeline and loses heat to the surrounding

subsoil. Line heaters along gas gathering system pipelines 

reheat the gas to prevent hydrates from forming.

at city gate stations where local distribution companies 

purchase, meter, regulate, and odorize the processed

natural gas received from transmission pipelines. The city 

gate station’s pressure regulators reduce the gas pressure

from its high transmission line pressure to the lower local 

distribution line pressure. Line heaters at city gate stations 

provide enough heat to prevent chilling of downstream 

equipment.

This module focuses on the operation of indirect-fired line

heaters at gas wellsites and along gas gathering system 

pipelines.

Figure 2 — Indirect-Fired Line Heater atWellsite(C ou r te sy  of P r e ss onE N E RF LEX and Pet r o - C anada  ) 

Augu s t , 2014 Pa g e 3  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 10/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Hydrates and Their Hazards 

Hydrates are a mixture of water and gas that forms crystals under certain temperature

and pressure conditions. In a hydrate, gas molecules (such as methane, ethane,

propane, butane, hydrogen sulphide, and carbon dioxide) are embedded inside a

lattice of water molecules. Hydrate crystals deposit on solid surfaces and restrict gas 

flow. Hydrates can plug valves, meters, instruments, and flow lines.

Hydrates:

-  can form at high pressure, even when the temperature

of the flowing gas is above the freezing point of water 

-  can form when free water condenses in the gas stream 

-  tend to form at sharp bends in flow lines and at locations where the pressure drops. However, hydrates can occur 

anywhere the temperature drops below the hydrate

formation point.

Hydrate formation can be prevented by:

-  operating at high gas temperatures 

-  operating at low gas pressures 

-  operating at a lower water content

-  in jecting a hydrate inhibitor, such as methanol 

Preventing hydrates from forming is important:

-  Clearing hydrate blockages is a high-risk activity. Incorrect hydrate removal can

cause pipeline/equipment rupture and put people in harm’s way.

-  Hydrate blockages interrupt business: a hydrate blockage means that gas is unable

to flow.

TEMPERATURE

HYDRATE "TRIANGLE"

HYDRATE    P    R    E   S   S    U    R

    EF     R     

E     E      W     A    T     E     R     

Indirect-Fired Line Heater ––Operating Principle

In an i nd ir e c t -fired line heater, a fire tube immersed in a heat

medium (HM), such as glycol, heats the HM (Figure 3). Thenatural gas passes through a flow coil that is also immersed in

the HM bath and is heated indirectly.

NOTE  In a d ir e c t -fired line heater, the fire tube is immersed in the

product being heated.

Augu s t , 2014 Pa g e 4  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 11/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Augu s t , 2014 Pa g e 5  of  77

NOTE  In this module, the terms li ne heate r  and heate r  refer only to

indirect-fired line heaters.

Figure 3 ––Line Heater Operating Principle

The fire tube heats the HM bath as follows:A fire tube is submerged in the lower part of the HM bath. A

flame travels down the fire tube and transfers heat to the

HM. Cooled combustion gases flow from the fire tube and

rise up a stack.

As the HM’s temperature increases, its density decreases to

create thermal circulation in the bath:

Hot, less dense HM rises to the upper part of the shell.

The gas flowing in the gas flow coil absorbs heat from 

the HM.

The HM’s temperature decreases and its density 

increases. The cooled HM sinks to the bottom of the

shell to be reheated.

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 12/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Line Heater Application and Site Requirements 

A line heater must be appropriate for site conditions: it must be

able to heat the gas enough to prevent hydrate formation.

Line heaters are usually skid-mounted and can be transferred

between sites. Before a line heater is transferred to a new site,

your company will ensure that:

the heater’s design specifications match conditions at the

new site

the heater and its components comply with regulatory 

requirements for the new site

This module describes line heaters that are correctly designed

for site conditions and meet regulatory requirements.

Indirect-Fired Line Heater ––Operator’s Role

Careful monitoring and control of indirect-fired line heaters 

contribute to the safe and efficient operation of the heater and

prevents hydrate formation in downstream piping. Operations 

include:

monitoring operating variables (temperature, pressure, bath

level, flow) to assess /optimize heater operation

starting up and shutting down the heater 

troubleshooting heater problems and rectifying minor problems 

promptly reporting ma jor problems 

Additional Operator responsibilities are described in Section 10.

Module Contents 

For indirect-fired line heaters, this module describes:

heat medium components 

combustion components 

combustion safety controls site layouts 

site systems and equipment

safety 

line heater burner lighting

operating variables and operations monitoring

troubleshooting

Augu s t , 2014 Pa g e 6  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 13/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Augu s t , 2014 Pa g e 7  of  77

2 Heat Medium Components This section describes the indirect-fired line heater’s shell and

produced gas flow coil.

NOTE  In this module:

the term p r odu c ed ga s  refers to the natural gas flowing

through the coil and being heated

the term fue l  ga s  refers to the gas that fuels the burner 

the term i n s t r u m entat i on ga s  refers to the natural gas or 

propane used to operate pneumatic controls 

2.1 Heater Shell

The heater shell is a horizontal, cylindrical vessel that operates 

at atmospheric pressure. The shell holds the large volume of

HM that transfers heat from the fire tube to the produced gas 

flow coil. The heater shell has two end flanges:

the produced gas flow coil is installed through one end

flange

the fire tube is installed through the other end flange

WARNING

 

For colder climates, the shell may be insulated. On older line

heaters, asbestos may have been used for insulation. Follow your company procedures for handling asbestos.

Expansion Tank

The heater shell has a top expansion tank (also called a s u r ge

tan k  or r e s e r v o ir ). The tank has sufficient volume:

to ensure that the heater shell is completely filled with HM 

(i.e., the liquid fully covers the produced gas flow coil) 

to accommodate HM expansion when the HM temperature

increases during cold startup

The expansion tank has a top hatch (thief hatch) that serves as 

both an HM fill port and a vent/breather. Because the shell can

only withstand atmospheric pressure, the hatch’s vent/breather 

provides both overpressure and vacuum protection:

Venting prevents shell rupture:

During line heater startup, the HM is heated to operating

temperature and expands. Air is pushed out the hatch.

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 14/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Augu s t , 2014 Pa g e 8  of  77

In case the flow coil ruptures, venting protects the shell 

from overpressure rupture.

Breathing prevents shell vacuum collapse. After the line

heater is shut down, the HM cools and contracts. Air is 

drawn in through the hatch to compensate for the decrease

in HM volume.

NOTE  For line heaters that have w ate r  baths, the expansion tank 

minimizes water vapor loss. This type of expansion tank is 

known as a w ate r  s a v e r . The lower temperature at the top of

the expansion tank condenses the steam rising off the liquid

surface.

Heating Medium 

The HM is either water or a glycol-water solution. A glycol-

water mixture has a lower freezing point and a higher boiling

point than water. The type of HM used depends on the climate

and required heating:

Water is used in hot climates where the HM does not have

to be protected from freezing. When using a water bath, a

line heater is operated below water’s boiling point to protect

against boiling off the bath water.

Distilled water may be used in colder climates. Compared

to water with impurities, distilled water freezes at a lower temperature.

Glycol-water bath solutions are used:

in cold climates where the bath must not freeze (in case

the line heater shuts down during cold weather 

operations) 

in any climate where a high bath temperature is required

The water and glycol-water solutions used in line heaters are

treated with corrosion inhibitors to prevent internal fouling and

corrosion. Your company may stipulate that:

a specific glycol-water mixture be used instead of vehicle

antifreeze

HM be sampled regularly to verify glycol / water 

concentration, freezing/boiling points, and corrosion inhibitor 

strength

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 15/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

The level of the heat medium is determined by two factors:

The fire tube and gas flow coils must be covered

Some empty space is required for thermal expansion

Follow the manufacturer’s recommendations for the required

level of the heat medium.

2.2 Produced Gas Flow Coil

The produced gas flow coil (also called the tube bundle) is a

removable length of piping installed above the fire tube in the

HM bath. Pressurized produced gas from the wellhead or 

pipeline is directed through the flow coil for heating.

The gas flow coil must always be completely submerged in theHM during line heater operation. Keeping the coil submerged

ensures that the produced gas in the coil is effectively heated.

The coil must remain submerged even after the line heater is 

shut off and has cooled. Remaining submerged ensures that

the coil is not exposed to the corrosive effects of the air (drawn

in through the vent/breather during cool down).

Engineering and/or regulatory codes dictate how the produced

gas flow coil is manufactured, pressure-tested, and re-tested/

inspected during the coil’s service life to ensure the coil canwithstand the high gas pressures.

The configuration of the coil depends on both:

the number of heating stages needed by the produced gas 

heating application (either one or two stages) 

the number of coils needed to handle the produced gas flow 

rate (either one coil for low flow rates or multiple parallel 

coils for higher gas flow rates) 

Heating Stages 

One heating stage is used on line heaters which must provide

only a moderate temperature increase (such as those on

gathering system pipelines).

Figure 4 on the following page show a one heating stage line

heater.

Augu s t , 2014 Pa g e 9  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 16/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Figure 4 —One-StageProduced Gas Flow Coil 

Two heating stages are used on line heaters which must

provide a great amount of heating to counter the intense

cooling caused by a large pressure reduction. (Large pressure

reductions commonly occur at sites where the wellhead gas 

pressure must be reduced to match lower gathering system 

pressure.) On two-stage line heaters (see Figures 5 and 6), the

coil provides a preheating stage befo r e  the pressure reduction

and a reheating stage afte r  the pressure reduction. (Preheating

the gas before a large pressure reduction ensures that the

cooling caused by the pressure drop does not chill the gas to

below hydrate-formation temperature.) 

The produced gas flows through the two-stage heater as 

follows:

the produced gas flow enters the preheat coil and is heated

the heated produced gas flow leaves the preheat coil and

passes through the pressure reduction valve (choke) 

after pressure reduction (and resulting cooling), the

produced gas flows into the line heater’s reheat coil, is 

heated to the final temperature, and then exits the line

heater. (The reheat coil is also known as the post-heat coil.) 

For line heaters equipped with preheat and reheat coils:

The preheat coil is built to withstand higher pressure than

the reheat coil.

The configuration of the pressure reduction valve (choke) 

between the preheat and reheat coils can vary:

Augu s t , 2014 Pa g e 10  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 17/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

The valve may be a manual valve whose body is 

immersed in the HM bath.

The valve may be an external control valve that is 

automatically positioned as part of a wellhead pressure

control or flow control strategy to maintain flow and/or 

pressure setpoint (as described in Section 6).

NOTE  For a detailed description of process control and control loop

strategies, refer to these HDC training kits:

D e sc ri be Ba s i c  In s t r u m entat i on and C ont r o l  St r ateg i e s  

D e sc ri be P r o c e ss  C ont r o l  M ode s  and P r o c e ss  C ont r o l  

T e c hno l og y  

Figure 5 —Two-StageProduced Gas Flow Coil 

Refer to the next page for a picture of a two stage gas coil and

choke.

Number of Produced Gas Coils 

Depending on the gas flow to be heated, a line heater’s 

produced gas coil may consist of a single coil or multiple,

parallel coils:

single coil. A single coil may be sufficient to heat a small 

gas flow. A single coil is configured as a spiral-wound

bundle or as a tube-type bundle (where the coil makes 

numerous passes back and forth before leaving the line

heater).

Augu s t , 2014 Pa g e 11 of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 18/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Figure 6 —Line Heater with Two-Stage Produced Gas Coil and Choke(C ou r te sy  of La r s en & D’ Ami c o M fg. Ltd. ) 

multiple, parallel coils. To heat a large gas flow, the flow to the line heater branches outside of the heater to feed

multiple, parallel, tube-type coils. After passing through the

heater, the flows recombine.

3 Combustion Components The burner directs a flame into the submerged fire tube to heat

the HM. The following components support the heater’s 

combustion operation (see Figure 7):

fuel gas supply fuel gas conditioning system 

burner fuel gas train

burner assembly 

fire tube assembly 

flame arrestor / wind box 

Augu s t , 2014 Pa g e 12  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 19/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

3.1 Fuel Gas Supply 

A line heater needs a reliable source of fuel gas. The fuel gas 

source may be:

a drawoff from the line heater produced gas outleta natural gas utility distribution network or nearby gas 

processing plant

a propane storage system 

Figure 7 —Line Heater’s Combustion Components 

Drawoff from Line Heater Outlet 

The produced gas heated in the gas flow coil may be of

sufficient quality to support efficient combustion. In this case, a

slipstream of heated produced gas is withdrawn downstream of

the line heater. The produced gas may contain toxic 

contaminants at trace levels that do not impair reliable

combustion. However, some contaminants are hazardous /toxic,

even at trace levels. Refer to Section 8.3 for safety precautions 

at line heater sites.

Augu s t , 2014 Pa g e 13  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 20/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Augu s t , 2014 Pa g e 14  of  77

In applications where produced gas is used as the fuel gas 

source, the fuel gas drawoff may be equipped with:

a manual isolation block valve

a pressure regulator to reduce the gas pressure

WARNING

 

When produced gas is used as fuel gas, the fuel gas typically 

does not contain a leak detection odorant. Although the fuel 

gas may have a petroleum odor, don’t assume that you will be

able to smell a fuel gas leak.

Natural Gas Utility or Nearby Gas Plant 

If the produced gas is not suitable, fuel gas may have to be

supplied from offsite. Two sources are:

commercial-quality natural gas piped from a gas utility distribution network 

sales-quality natural gas from a nearby gas plant

NOTE  At some remote gas plants, a slipstream of sales gas is 

withdrawn to supply equipment in the surrounding gas fields.

In applications where the fuel gas arrives from offsite, the fuel 

gas piping may be equipped with:

a manual isolation block valve

an ESD (emergency shutdown) valve to close automatically in case of a site emergency 

a pressure regulator to reduce the gas pressure to an

intermediate pressure

a flowmeter to record fuel gas consumption

WARNING 

Find out if the fuel gas at your site is odorized:

Fuel gas arriving from an offsite location may contain a leak 

detection odorant.

Fuel gas from a gas utility is typically odorized, whereas 

fuel gas from a gas processing plant may not be. Don’t

assume that you will be able to smell a fuel gas leak.

Propane Storage System 

If the produced gas is not suitable for use as fuel gas, another 

option is to use propane supplied from a storage system. The

propane storage system consists of an outdoor propane

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 21/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

storage tank that holds a large volume of liquid propane under 

pressure. The propane is withdrawn from the tank using either:

propane li qu i d  drawoff (for larger capacity systems) 

propane v apo r  drawoff (for smaller capacity systems) 

Propane Liquid Drawoff 

Propane liquid flows or is pumped from the bottom of the tank 

through the tank’s manual liquid isolation valve. The propane

liquid is then heated in a specialty heater known as a propane

vaporizer.

Propane Vapor Drawoff 

Propane vapor leaves the top of the tank through the tank’s 

manual isolation valve and is directed through a regulator to

reduce the propane pressure.

A propane tank configured to supply propane vapor may have

difficulty supplying sufficient vapor during cold weather. A

propane tank’s ability to discharge vapor declines as the

outdoor temperature drops and the tank’s propane level drops.

To prevent an interruption in propane vapor flow, the propane

tank may be winterized with an external flameless heater (a

catalytic heater, described in Section 7.1). The heater provides 

radiant heat to the tank’s wall to ensure sufficient propane

vapor.

Propane System Monitoring 

The Operator checks the propane system to ensure continued

fuel gas supply:

monitors propane storage tank pressure and requests a

propane refill, if necessary 

confirms that the propane system’s valves are correctly 

configured

during the winter, confirms the operation of the propane

tank’s heater and flow of propane vapor from the tank 

WARNING 

At sites where propane is used as fuel gas, your personal 

combustible gas detector must be able to detect:

propane fuel gas leaks 

methane produced gas leaks 

Consult your company’s health and safety practices.

Augu s t , 2014 Pa g e 15  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 22/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

3.2 Fuel Gas Conditioning System 

All fuel gas undergoes conditioning (see Figure 7):

fuel gas preheating

fuel gas scrubbingadditional fuel gas filtration

Fuel Gas Preheating 

The fuel gas passes through a preheat coil immersed in the HM 

bath. After heating, the fuel gas flow branches and flows 

through pressure regulators in the main burner and pilot burner 

supply lines. Preheating the fuel gas before it flows through the

pressure regulators prevents hydrates from forming.

Fuel Gas Scrubbing 

Liquids entrained in the fuel gas must be removed to prevent:

poor burner operation; the liquids may not burn consistently:

the burning liquids may produce a smoky flue gas 

exhaust

the liquids may not burn and may pool at the bottom of

the firebox housing. This pooled liquid may drain out of

the firebox flame arrestor, creating a fire hazard. The

pooled liquid may suddenly ignite or explode.

discharge of flammable droplets out the top of the flue stack 

which may ignite surrounding vegetationliquid entry into instrumentation lines. Liquids interfere with

the operation of pneumatic controls and instrumentation.

The fuel gas scrubber is a small separator where liquids in the

incoming fuel gas settle to the bottom and the gas rises to the

top outlet.

In case of a high liquid level in the scrubber, the scrubber’s 

protective controls stop the flow of fuel gas, shutting down the

line heater burner. The scrubber’s high level protective controls may consist of:

an internal float ball that rises with the liquid until the ball 

seals off the scrubber’s fuel gas outlet

a float level switch that is triggered at a preset liquid level to

stop the flow of fuel gas by closing a shutoff valve.

Augu s t , 2014 Pa g e 16  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 23/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

The scrubber’s drain valve depends on the liquid content of the

fuel gas:

At sites where the fuel gas normally contains liquid, the

scrubber has a drain valve that automatically opens at a

preset level to empty the scrubber to a liquid drain system.

At sites where the fuel gas does not normally contain

liquids, the scrubber may have only a manual drain valve.

Because liquid accumulation in the scrubber is abnormal,

any liquid would be drained manually to a portable container 

and disposed by the Operator. The Operator must perform 

liquid drainage/disposal in accordance with company safety 

procedures and company / regulatory waste/effluent disposal 

policies.

The fuel gas scrubber has a pressure safety valve (PSV) that

opens to relieve excessive pressure to prevent scrubber 

rupture. Overpressurizing of the scrubber can be caused by 

upstream regulator failure.

Additional Fuel Gas Filtration 

Some line heaters may be equipped with fuel gas filtration,

depending on the contaminant(s) to be removed:

To remove solids, a metal mesh strainer or a particulate

filter is used. The strainer’s removable mesh element can

be cleaned and reinstalled; a particulate filter’s internal elements are replaceable.

To remove liquid mist, a coalescing filter is used. The

coalescing filter’s elements are replaceable.

3.3 Burner Fuel Gas 

The burner fuel gas piping/ valving assembly:

receives conditioned fuel gas 

branches to direct the fuel gas to the heater’s main burner 

and pilot burner controls the flow of fuel gas to ensure safe operation of the

heater’s main burner and pilot burner 

The specific fuel gas valving/ control configuration is determined

by regulatory and insurance requirements and company 

policies.

Augu s t , 2014 Pa g e 17  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 24/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

The more stringent requirements incorporate a higher level of:

safety redundancy 

burner safety controls to automate burner operation and the

burner’s safe startup/ shutdown

instrumentation to enable local and remote monitoring

This section describes fuel gas valving; Section 4 describes 

how the valving is controlled as part of safe line heater 

operation, startup, and shutdown. Figure 8 shows the main

burner and pilot burner fuel gas flows.

Figure 8 —Main Burner and Pilot Burner Fuel Gas Flows 

Augu s t , 2014 Pa g e 18  of  77

7/21/2019 Indirect Fired Heater Training Module

http://slidepdf.com/reader/full/indirect-fired-heater-training-module 25/25

D escri b e a nd  O p era t e

I nd irec t-F ire d  Li n e H ea t ers

Augu s t , 2014 Pa g e 19  of  77

Fuel Gas Flow to the Main Burner 

Conditioned fuel gas flows to the burner fuel gas train and

passes through the following components to feed the main

burner:a manual block valve used to isolate the line heater from 

the fuel gas supply when the line heater is shut down

a pilot gas drawoff. As described later, this drawoff may be

located either upstream or downstream of the burner safety 

shutoff valve.

a pressure regulator that reduces the fuel gas pressure to

the optimum main burner pressure. The regulator is typically 

equipped with a pressure gauge.

one or two main burner safety shutoff valves that

automatically closes to shut off the fuel gas flow duringabnormal operation. Shutting down the flow prevents an

accumulation of fuel gas, which could lead to a line heater 

explosion. Abnormal operation includes:

End of Sample