industrial control products - schaedler yesco distribution inc
TRANSCRIPT
Schaedler Yesco
Industrial Control Product Update
Review of new product lines and additions to existing product offerings offered by Allen-Bradley Industrial Control Components.
•1606-XLP15A (5Vdc)
•1606-XLP15B (12Vdc)
•1606-XLP15E (24Vdc)
Small Size, only 22.5mm wide! Wide Range AC Input (100-240AC) Screw Terminals (To slim for spring clamps)
***LOW COST*** 1606-XLP15E List price = $65.00
***1606-XLP15…***
1606-XLE80E
• 3.3A (80Watt) Power Supply
• 100-240Vac input (Wide range voltage input)
• 120% continuous power boost
• Low AC inrush
1606-XLS Product Family
1606-XLS Line Extensions:
•120W (5A)
•80W (3.3A)
•240W (10A)
•960W (40A Three Phase, 20A Single and Three Phase)
•DNET (4 & 8 amp)
•Redundant Module
What are the RA Power Quality Products?
Product Overview – Ethernet Media
M12 Connectivity
RJ45 Connectivity
Accessories
Branch Circuit Type Lighting Contactor
Feeder Type Lighting Contactor
500L, 500FL, 500LP
Lighting Panelboard
Lighting Panelboard
500LC
500LG
To turn ON and OFF large blocks of lights
To control a specific number of branch circuits or luminaries
Suitable for areas requiring periodic maintenance
Combination Lighting
Contactor 502L, 503L
A-B NEMA Lighting Contactor Family
Contactor available in 2 to 12 power poles configuration Power poles available in 1-pole or 2-pole configuration Power pole rating: • up to 30A max for ballast, general use and AC
resistive load types • up to 20A max for tungsten load type • up to 15 HP motor rated (3-phase) Wide range of voltages with 50/60Hz options
A600 Auxiliary Contacts Enclosed contacts resist contaminants for greater
reliability Available in both mechanically and electrically held options Mechanically held version is available with either 2-wire or 3 wire control module
Bulletin 500LG
30A
2…12 poles
Electrically Held
Bulletin 500LG
30A
2…12 poles
2 wire or 3 wire control
Mechanically Held
500LG Mechanically Held Product Overview
Copyright © 2010 Rockwell Automation, Inc. All rights
reserved. 9
MachineAlertTM Monitoring Relays
MachineAlert Monitoring Relays • Panel builders, electrical controls designers and OEMs are
looking for cost effective ways to protect their electrical equipment investment
• These monitoring relays provide supplemental electronic motor protection including: – Current Monitoring Relay – Voltage Monitoring Relay – Active Power (kW) Monitoring Relay – Power Factor (cosθ) Monitoring Relay – Thermistor Monitoring Relay
Provides supplemental protection in conjunction with the
E1 Plus and E3 Plus Electronic Overload Relays
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. 10
Bulletin 931 – Analog Signal Conditioners
Solutions for all common analog signal conditioning requirements Isolation Conversion (e.g. 0-10Vdc to 4-20mA, etc.) Transmission/Amplification/Linearization
(thermocouples, RTDs, etc.) Extensive offering
Simple (fixed function) to universal (programmable)
Variety of form factors – 6mm to 45mm Global Approvals
• CE • cULus or cURus/CSA • Hazardous Location Approvals
• cULusEx (Class 1, Div 2 and Zone 2
11
Bulletin 931 – Analog Signal Conditioners
Highest level of isolation, accuracy
Increased level of isolation, accuracy
Basic, simple signals
Universal - 12.5mm or 45mm
Standard - 12.5, 17.5 or 22.5mm
High Density -6mm
Fixed or DIP switch configurable
Inputs • Current, Voltage, Temperature, Potentiometer, Frequency
Outputs • Current, Voltage • Alarm/Relay output (Threshold Monitoring)
Inputs • Current, Voltage, Temperature, Potentiometer, Frequency, Bridge
Outputs • Current, Voltage • Alarm/Relay output (Threshold Monitoring) • Splitter
Inputs • Current, Voltage, Temperature
Outputs • Current, Voltage • HART pass through
931U 931S 931H
Fixed or DIP switch/Jumper configurable
Software configurable
Bulletin 156 Solid State Product Overview Compact modular design
complete with heatsink Simple Installation LED Status indication Panel or DIN rail mountable Zero Cross Switching Available in single phase,
dual, or three phase versions
AC, DC, and Analog control options
Product Overview
Operational Voltage Ratings: Current Ratings (A):
Single Phase (20, 30, 45, 50, 70, 75, 90 Amps)
Dual Phase (25 and 32 Amps)
Three Phase (20, 25, and 32 Amps)
Current Monitoring (30 and 50 Amp)
Analog Switching (30 and 50 Amp)
24-265 V AC 24-600 V AC
Control Voltage Ratings:
5-24 V DC 24-230 V AC/DC Analog Control (4…20mA ,
0…10V)
Copyright © 2009 Rockwell Automation, Inc. All rights reserved.
800B 16 mm Push Buttons
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 15
New Product Announcement
• Rockwell Automation – Allen-Bradley is pleased to announce a new line of 16 mm Push Buttons
• Replaces and Expands Existing 16 mm Product Offering • Modular Design – No Composite Catalog Numbers
– Simple Assembly At Customer Location – Reduced Distributor and RA Inventory – Same as Other RA Push Button Product Offerings
• New Offerings – Emergency Stop Operator and Legend Plates – Illuminated Selector Switches
• AFC – January 2011
800B 16 mm Push Buttons
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 16
Applications/Target Markets
Key Industries • Manufacturing • CNC Machines • Process Control Equipment • Packaging • Instrumentation
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 17
Product Overview - Operators
• Operators – Momentary Push Buttons and Pilot Lights – Cap less
• Round, Square, Rectangle and Large Square – Maintained Push Buttons – Cap less
• Round, Square, Rectangle and Large Square – Selector Switches – Round only
• 2- and 3-Position • Maintained and Spring Return • Keyed and non-keyed • Illuminated (Optional)
– Emergency Stop – Trigger Action
• Twist-to-Release • Non-Illuminated
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 18
Product Overview – Lens/Bezel
• Lens and Diffuser – Round, Square, Rectangle
and Large Square – Green, Red, White, Yellow and Blue
• Bezels – For Round Operators – Square, Rectangle and Large Square – Selector Switch Applications
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 19
Product Overview - Illumination
• Illumination – LED
• Green, Red and White • 12 … 24V AC/DC, 120V AC
– Incandescent
• 6V AC/DC, 12V AC/DC, 24V AC/DC
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 20
• Slow Make/Break Contact Blocks • E-Stops, Push Buttons & Selector Switches
– 1 NC Slow Make/Break
– 2 NC Slow Make/Break
– 1 NO / 1 NC Slow Make/Break
Product Overview – Contact Blocks
• Snap Action Contact Blocks • Push Buttons & Selector Switches
– 1 NO / 1 NC Snap Action
– 2 NO / 2 NC Snap Action
– Pilot Light Block
Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 21
Product Overview – Customer Assembly
• Ease of Assembly Sequence 1. Operator into Panel
– Mounting Ring 2. Illumination Option 3. Lens Cap 4. Contact Block
1
1A
2
3 4
(Confidential – For Internal Use Only) Copyright © 2008 Rockwell Automation, Inc. All rights reserved. 22
New 800T/H Universal LED Illumination
Universal Means:
• Wide input voltage range – 12 … 130V AC/DC
• Broad product compatibility
– 800T/H 30.5mm – 800H/HL Type 7&9 Exceptions: 18mm and pigtail pilot lights
• Extensive device compatibility
– Pilot Lights (Standard and Push-to-Test) – Illuminated Push-Buttons – Illuminated Push-Pull Devices – Illuminated Selector Switches
(Confidential – For Internal Use Only) Copyright © 2008 Rockwell Automation, Inc. All rights reserved. 23
New 800T/H Universal LED Illumination
Product Overview
• New Universal power module (800TC-N374) – 12…130V ac/dc input voltage range – Pass-through plunger – Solid-state output compatibility
• shunts up-to 3mA of leakage current – Finger-safe terminals as standard – Ring lug compatible
• New LED lamps (800T-N376*)
– Green, Red and White • white used with amber, blue, clear, and white color lenses
– Bright, state-of-the-art LED technology – T3-1/4 bayonet base
• allows lamp replacement
* G (green), R (red), W (white)
New 800T/H Universal LED Illumination
(Confidential – For Internal Use Only) Copyright © 2008 Rockwell Automation, Inc. All rights reserved. 24
Universal LED module pass-through plunger
• Allows stacking - addition of third contact block – Illuminated push-buttons – Illuminated push-pull devices – Push-to-test pilot lights
pass-thru plunger
(Confidential – For Internal Use Only) Copyright © 2008 Rockwell Automation, Inc. All rights reserved. 25
New 800T/H Universal LED Illumination
Cat. No. Explanation - Pilot Lights
800T - QH __ __
Voltage Rating Lens Color • 2 12 ... 130V ac/dc A amber • 06 6V ac/dc B blue • 10 120V ac C clear • 12 12V ac/dc G green • 13 130V ac/dc R red • 24 24V ac/dc W white • 32 32V ac/dc • 48 48V ac/dc
Discontinued (for LED)
140U-D Product Overview
Compact current limiting UL489 circuit breaker
• Protection Functions – Short circuit protection – Thermal overcurrent protection
• Features
– Fixed magnetic / fixed thermal trip – Short circuit trip level 15...20 x In – Current limiting – Interrupting rating @480Y/277: up to 100kA – 100% rated up to 15A
• Standards
– UL489 / CSA22.2 No.5 – IEC60947-2
• Footprint
– 45W x 102H x 85D mm / 1.77W x 4.02H x 3.53D inch
Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
140U-D Product Overview
• Product Range – 2 & 3 pole
• 140U-D6D2.. & 140U-D6D3.. – 0.5...30A
• 14 device ratings: 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 15, 20, 25, 30 Amp
• Accessories – Compact busbar and feeder blocks – 140M front mount accessories (aux. contacts,
knobs, door handle) – Contactor connection modules
3-pole
2-pole
2 & 3 pole devices up to 30A Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
• Compact bus bar 64A • Terminal block 64A • Connection Modules
– Eco connection module 25A – Flexible wire module 32A
• Accessories from 140M line – Front mount auxiliary contacts – Lockable knobs – Door handles Series E (and later), AFC
July 11 – Shunt and under voltage trip units Series
B (and later), AFC Sept 11
• Load side terminal cover for UL489 compliance when front mount auxiliary contacts are installed
140U-D Accessories overview
Simplify product use in many applications Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
140U-D Circuit Breaker
Device Rating
Test trip actuator
Handle trip position @ 45°
Trip differentiation flag (differentiation between short
circuit and overload trip)
Handle with 3 positions - ON - OFF - Trip
Marker holder for 1492-MS10X17, 1492-M6X12 or 100-FM
Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
140U-D Circuit Breaker
• Trip indication & differentiation – separate trip position of handle – short circuit trip indicator flag
• Easy fault finding – trip indicator distinguish between overload and
short circuit trip – makes fault finding less time consuming – assists operators in troubleshooting and
minimizing downtime
Trip differentiation – Unique feature
Overload trip indication
Short circuit trip indication
Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
Thermal-Magnetic, Fixed Thermal-Fixed MagneticRated Magnetic
Current Trip [A]Im
I n [A]
Icu Ics Icu Ics Icu Ics
0.5 15...20 x In 100 65 65 65 50 50 100 100 50 140U-D6D2-A50 140U-D6D3-A50
1 15...20 x In 100 65 65 65 50 50 100 100 50 140U-D6D2-B10 140U-D6D3-B10
2 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B20 140U-D6D3-B20
3 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B30 140U-D6D3-B30
4 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B40 140U-D6D3-B40
5 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B50 140U-D6D3-B50
6 15...20 x In 100 65 65 65 18 10 100 100 50 140U-D6D2-B60 140U-D6D3-B60
8 15...20 x In 100 65 65 65 10 6 100 100 50 140U-D6D2-B80 140U-D6D3-B80
10 15...20 x In 100 65 65 65 10 6 100 100 50 140U-D6D2-C10 140U-D6D3-C10
12 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C12 140U-D6D3-C12
15 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C15 140U-D6D3-C15
20 15...20 x In 65 50 65 50 10 6 65 65 35 140U-D6D2-C20 140U-D6D3-C20
25 15...20 x In 65 50 65 25 10 6 65 65 35 140U-D6D2-C25 140U-D6D3-C25
30 15...20 x In 65 50 65 25 10 6 65 65 35 140U-D6D2-C30 140U-D6D3-C30
Up to 15A suitable for continuous operation at 100% of rating only if used in a cubicle space of 250 x 175 x 150 mm (10 x 7 x 6 inch)‡ Current Limiting - data see specification or www.ab.com/catalogs
3 Pole
Cat. No.‡
480Y/277V 600Y/347V
Breaking Capacity (50 Hz) Interrupting Rating (60 Hz) 2 Pole
Cat. No.‡
[kA] [kA]
400…415V 525V 690V 240V
140U-D Interrupting Ratings
High Interrupting Ratings Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
Key Benefits 1. Safety: Removable fuse carriers –
for J, CC, DIN, BS88 and NFC fuses
Fuse carriers interlock with switch when switch is ON
IP20 finger-safe terminals Blown fuse indication in fuse carriers (optional) Internal handle for
compliance with NFPA 79 requirements
(optional)
194R Next Gen 30/60A Benefits
Copyright © 2012 Rockwell Automation, Inc. All rights reserved. Copyright © 2012 Rockwell Automation, Inc. All rights reserved. 33
Bulletin 194R Fused & Non-Fused Disconnects (100 through 1250A)
Product extension to our family of disconnect switches, molded case circuit breakers, motor protection circuit breakers and motor circuit protectors
194R-NU100-1753
194R-D160-1753
194R New Product Announcement
Copyright © 2012 Rockwell Automation, Inc. All rights reserved.
Construction:
• Modular Construction
• Each phase is capsulated (electrically isolated)
• Minimizing possible phase to phase short
• Clearance & Creepage distances per UL98
• 200 kA Short Circuit rating for UL Disconnects
• 200kA Short Circuit rating for 100A IEC Disconnect
• 100kA Short Circuit rating for 200, 400, 600 & 800A IEC Disconnects
Fused Disconnect - Construction
(Confidential – For Internal Use Only) Copyright © 2012 Rockwell Automation, Inc. All rights reserved.
35
854J & 854K Tower Lights Overview
• 854J (40 mm) and 854K (60 mm) – Modular construction design – Offered as separate components or as Pre-
configured arrangements from factory – Spring Clamp Terminal blocks on the bases. – “Tool-free” lens assembly that ease installation time. – Ingress Protection cULus Type 4/4x/13, IP66 in all
bases, Light and sound modules • Suitable for Indoor/ Outdoor use
– Wide variety of mounting options and accessories
The modular design of the 854J and 854K allows easy, tool free assembly and customization in the field or plant floor
(Confidential – For Internal Use Only) Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
854J & 854K -Bases
• Versatile offering of mounting options: – Vertical mounting base – Pole Mount Bases (10 and 25 cm length)
– Threaded Tube bases (10 and 25 cm length)
– Quick release Base (10 and 25 cm. length)
– ½ in. NPT Base – Surface Mount Base- Flange Style – Surface Mount w/ preinstalled screws – Double Sided Base
• Can accommodate up to10 modules in one single arrangement
Note: All Bases will be supplied with cap.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 36
½” NPT Base
Surface Mount –Flange Style Base
Vertical Mount Base
Double Sided Base
854J & 854K -Light Modules
• Available in 24V DC, 120V AC and 240V AC • Light Modules functionality (for both 854J & 854K):
– Steady Incandescent – Steady LED – Flashing LED – LED Strobe
• Exclusive for the 854K: – Multi flash LED (available in 24VDC only)
• Six Colors available for every function – Red, Green, Amber, Blue, Clear, Yellow – LED color matches Lens Color – Color coded nameplate to identify module’s operating voltage
• There is no restriction on having different illumination technologies in the same tower Light.
• Incandescent Light modules are field assembled and requires to purchase Lens and bulb separately
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 37
854J & 854K -Sound Modules
• Single Circuit Sounder – Piezoelectric technology – Selectable Continuous/Pulsing via DIP Switch – Estimated output level @ 1 m:
• 80dB(A) for the 854J • 90 dB(A) for the 854K - Volume adjustable
– Preserves the IP66 rating when installed on the stack. • Always mounted on top
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 38
854J Sounder
Continuous/Pulsing DIP Switch
854K Sounder
854J & 854K -Accessories
• 4 Watts Incandescent bulbs – Sold in packs of 5 pieces per box – Incandescent solution for the 854J and 854K Tower Lights
• 10 cm plastic base extension – Works with Surface, ½ in NPT or Vertical Mount bases – Adds 10 cm height to the Tower Light assembly and preserves IP 66 rating
• Double Sided Mount base – Allows to have up to (10) modules in one single stack arrangement – It could be used for vertical or horizontal mounting
39
10 cm base extension
Double Sided base
Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
854J & 854K Preconfigured versions
• Pre-configured versions available for
24V AC/DC and 120V AC
• Bases available as configured option – ½” NPT, Vertical mount, Surface Flange style,
Pole Mount (10&25 cm) and Quick Release Base (10 & 25 cm length)
• Light Module options:
– Steady LED, Flashing LED and Strobe LED
• Sounders – Piezoelectric Single circuit
40 Copyright © 2011 Rockwell Automation, Inc. All rights reserved.
Ideal for applications that require always the same stack configuration
Copyright © 2012 Rockwell Automation, Inc. All rights reserved.
Bulletin 855H Recordable Horn
855H Recordable Horn Overview
• Logical migration on applications that require an additional level of audible annunciation beyond the traditional sounder tones
• The new 855H-R will allow customers to download or record in the same unit: – Voice – Melodies – Customized tones provided by the user
• Displays clear messages to avoid confusion or to provide specific advice
in the actions to take when an alarm is present.
• Preserves the same “Look and Feel” of our High Performance Horns
Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H Recordable Horn Frame Sizes
Frame C (DC Version)
Frame E (AC & DC Versions)
Frame C (AC Version)
Flare Style Version
Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H Recordable Horn Product Overview
• Three sizes available to cover most of the applications: – Frame C
• dB Output : 101db(A) @ 1m Voice, 110dB(A) @ 1 m Tone – Frame E and Flare Style:
• dB Output : 111db(A) @ 1m Voice, 126dB(A) @ 1 m Tone
• Extended Voltage Operating range for all frames – 10…30V DC (Frame C Horn) – 12….30V DC (Frame C combo) – 14…30 V DC (Frame E and Flare Style Horns and frame E combo) – 90…260V AC (AC version for all Frames)
• cULus Type 4/4X/13/3R, IP 66 Ingress protection rating. • Available as stand-alone Horn or Combination Unit (Horn and Beacon)
– Continuous/ Flashing LED Beacon (DIP Switch Selectable) – 2Hz Flashing frequency – LED Colors available: Green, Red and Amber
The highest dB(A) output level for Messages in the Industry! Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H Recordable Horn Recording Features
• Two ways to record a message in the unit: – Via the On-Board Microphone (ideal for single Installations) – Via the 3.5 mm Audio Input (allows recording from analog sources)
• Total of 2 minutes of recording capacity – Split in 4 channels (stages) of 30 sec. max per channel – The Horn will edit time to match recorded content
• Exceptional CD Quality recording – 32KHz recording sample rate- CD Quality – 16KHz playback sample rate that produces exceptional clarity – Depends on the original quality of recorded content
• Line Level Peak indicator – Indicates that output volume has been set at the optimum level at the source device – Ensures maximum SPL (Sound Pressure Level) at message play-back
• “Message only” or “Message and Tone” Playback selectable
No additional Hardware needed to record a message! Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H Recordable Horn Additional Features
• Separate Volume control for Tone and recorded content – Enables independent output levels for Tones and Messages
• Up to 4 remote selectable stages – Selected by standard “Negative switching” on DC Units
• 45 Tones to select via Dip Switches – Optimized selection for better tone contrast between stages
Automatically pre-set when Stage 1 is selected via DIP switch
Stage 1 selected via DIP switch
Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H- Recordable Horn Stage Remote Selection
• “Negative Switching” to enable the (4) Stages: Stages Control for DC Units
Message 1 will be played when (+) and (-) are present Message 2 will be played when (+) and (-) are present and S2 is closed Message 3 will be played when (+) and (-) are present and S3 is closed Message 4 will be played when (+) and (-) are present and S4 is closed
DC Units AC Units
Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
855H Recordable Horn Additional Features
• “Play-through” capability – Listen the content as it is being recorded – Available when downloading is made from an analog source
• Master-Slave Functionality – The message is recorded only in the Master unit. – Replicate content to other devices using a single cable – If the recording is missed in the master unit the messages can be retrieved from a slave unit.
• Synchronized output in multi-horn installations – Similar to the High Performance Horns by Daisy chain the (+) and ( -) Terminals in the Horns. – Jumper in the Synch mode
• No need to perform message format conversion – No proprietary Software required – No third-party freeware/shareware required.
Functionality that saves Installation and Commissioning time
Copyright © 2010 Rockwell Automation, Inc. All rights reserved.
Thank You !!
November 7-8, 2012 100+ Vendors
16 Hands-On Labs, 63 Technical Sessions (Each Day)
Schaedler Yesco will be offering transportation and lodging packages Details coming Summer 2012