industrial manufacturing of caustic soda flakes at tamilnadu petroproducts ltd

84

Click here to load reader

Upload: hemant-gaule

Post on 12-Nov-2014

4.497 views

Category:

Documents


7 download

DESCRIPTION

the report describes the Industrial Manufacturing Process of caustic soda flakes, as employed by tamilnadu petroproducts limited, manali, chennai.

TRANSCRIPT

Page 1: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Vocational Training Report

ONManufacturing of Caustic Soda Flakes

Heavy Chemicals Division,Tamilnadu Petroproducts Ltd, Manali

By: Hemant Gaule (U04CH115)

B.Tech-IV, Chemical Engineering

Page 2: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Acknowledgements

The period of my vocational training at the Heavy Chemicals Division of Tamilnadu Petroproducts Limited was a great learning experience for me. It helped me relate the theoretical aspects of Chemical engineering to the practical working and functioning of various phases of production of caustic soda flakes. This, however, could not have been without the efforts and co-operations of the employees and mentors at TPL. This report is credit to the contributions and generous aids provided by the members of TPL, and hence I am obliged to say a word of thanks to everyone who helped me with their guidance throughout the training program.

I am thankful to Dr. R. Krishnan, Technical Head, Heavy chemicals division for his generous help throughout the training.

I would like to thank Mr. R. Joseph Premkumar, Executive (Training) for giving me the opportunity to undergo this training program.

I would like to thank Mr. M. Yerumalai, Technical Head, Brine House for his help and support.

I am thankful to Mr. V. Malayan, Operator, Brine House for all his help and co-operation.

I express my thanks to Mr. M, Vijayamohan, Chief of safety, HCD, for his generous guidance.

I would also like to thank all the employees at HCD, TPL for all their support and co-operation.

HEMANT GAULE

Page 3: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Contents

Chapter 1 General Outline

Chapter 2 Process Description2.1 Primary Brine Treatment

2.1.1 Anthracite Filters2.1.2 Precoat Filters

2.2 Secondary Brine Treatment2.2.1 Polishing Filters2.2.2 Depleted Brine Dechlorination

2.3 Electrolyzers2.4 Caustic Concentration

2.4.1 Caustic Evaporation Plant2.4.2 Fusion Plant

Chapter 3 Demand, supply and manufacturers in India

Chapter 4 Line Sizing

Chapter 5 Instrumentation

Chapter 6 Pumps and valves

Chapter 7 Motors, RPM, make types;

Chapter 8 Environmental Issues

Summary

Page 4: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

1.General Outline

The plant is designed to produce close to 100 TDP of caustic soda by Ion Exchange Membrane electrolysis process. This process has replaced the Mercury Cell process as it produced huge amounts of mercury as waste, which was highly toxic to the environment. Chlorine and Hydrogen gases are liberated as side products.

The raw materials are raw salt, water and power. The final products are a) 32.5 wt% caustic soda (concentrated to 48% in existing mercury cell)b) liquid chlorinec) hydrogen gas

The plant consists of sections for raw material treatment, electrolysis, product treatment and utility supply. The chemical process, however, may be broadly classified into three sections:

Table 1General Outline

Section No. Section nameI Brine treatment section

a) Primary brine precipitation and chemical preparationb) Primary brine filtrationc) Sludge treatmentd) Secondary brine purificatione) Brine dechlorination

II Electrolysis (32% caustic, H2, Cl2 as products)III Caustic concentration

a) Caustic Evaporation Plant (32% caustic to 48% caustic lye)b) Fusion Plant (48% caustic lye to 98% caustic flakes)

Page 5: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2. Process description

2.1 Primary brine purification

The depleted brine after vacuum dechlorination and sodium sulfite treatment is sent to, the saturators. Two saturators are provided; one working and one stand by. However, when one is in service, a small quantity of depleted brine is sent through the other saturators to prevent clogging of dip pipe as well as to remove the impurities by leaching.

During the electrolysis, some amount of water from brine will be transported to the cathode compartment along with the sodium ions. This water loss from brine is made up by adding DM water tom the depleted brine before tit enters the saturators. The concentration of crude brine is controlled by mixing some amount of lean brine with saturated brine from the saturators inside a strainer tank.

Raw salt contains many insoluble matters, which get settled at the bottom of the saturators. These insolubles are removed periodically from the bottom of saturator. The bottom discharge is collected in a saturator recovery pit. When the insolubles are settled, the clean brine is recovered back to the saturator by the raw salt sludge pump.

The crude brine contains impurities like calcium, magnesium, sulphates, heavy metals etc. the calcium, magnesium and sulphates are eliminated by treating the crude brine with the sodium carbonate, sodium hydroxide and barium carbonate respectively. The reactions are carried out in two reactors. The sodium carbonate and barium carbonate are added to the first reactor and sodium hydroxide in the second rector. To speed up the reaction and to prevent settling of precipitators, both reactors are provided with agitation. The first reactor is agitated with air and the second one with mechanical agitator (since any air bubble trapped in the brine affects the settling efficiency of clarifier, in the second reactor air agitation is not used.).

Following reaction occur in the reactors:

Na2SO4 + BaCo3 BaSO4 + Na2CO3

CaSO4 + BaCO3 BaSO4 + CaCO3

MgCl2 + 2NaOH Mg(OH)2 + 2NaClCa+ + + Na2CO3 CaCO3 + 2 Na+

The flow rate of 10 % Na2CO3 and 20 % NaOH supplied to the reactor are controlled to get an excess sodium hydroxide content of 150 – 200 mgpl and excess carbonate content of 250 – 300 mgpl in the brine at the outlet of second reactor. Barium carbonate slurry concentration is kept at around 16 wt%. The brine recovered from various operations are collected in a pit and supplied to the first reactor at constant flow rate. For the stable operation of the clarifier, it is advisable not to allow major variations in the flow rate of recovered brine.

Crude brine overflowing from the second reactor enters a flocculants mixing tank where 0.05 wt% flocculants solution so that the concentration of flocculants in brine is maintained at around 5 ppm. (This quantity may further be reduced as per the actual performance of the clarifier).

The brine then overflows into the clarifier where the residence time is long. In the clarifier, all the reactions are completed and the precipitates get settled at the bottom. The precipitates are periodically removed from the bottom and sent to the vacuum drum filter using clarifier sludge pump.

Page 6: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The clarifier is a water seal type, where a layer of water is always maintained on the surface of brine to prevent heat loss from brine due to radiation and to prevent convection current (thereby settling is improved). If the water layer decreases, the sealing water temperature increases. Then the clarifier is to be supplied with additional sealing water supply at the top. DM water is used as the sealing water.

The clarifier brine overflows into the CB tank. The suspended solid of this brine is about 20 ppm or less.

SLUDGE FILTRATION AND BRINE RECOVERY

1. Clarifier underflows, precipitates underflow and the backwash from polishing filter are collected in the sludge pit.

2. The polishing filter backwash, clarifier underflow are filtered using vacuum filter and the filtrate is collected in recovered brine pits.

3. The backwash brine from Anthracite filters, various tank overflows and the filtrate from vacuum drum filter are collected in the recovered brine pits.

4. From the pit recovered brine is continuously fed to the brine circuit at a constant flow rate using recovered brine pumps.

Page 7: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Fig 1 Primary Brine Treatment

DMWater

DepletedBrine

FIC

Saturator

StrainerMixing Reactor

I

Mixing Reactor

II

pH

Mixing Tank

16%BaCO3

10%Na2CO3

20%NaOH Floxin

Clarifier

ClarifiedBrine Pump

FIC

FIC

Backwash pump

ClarifiedBrine Tank

LIC

FilterBackwash

Filtered Brine Tank

Filtered BrinePump

Body Feed Tank

Na2SO3

Prep Tank

LIC

Polishing Filter

AIC

Polished BrineTank

Polished Brine Pump

To Secondary Brine System

Page 8: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Table 2(a) Parameters

PRIMARY BRINE PURIFICATION

NO. ITEM STANDARD UPPER LIMIT

LOWER LIMIT

1 Saturator brine concentration

305 gpl 315 gpl 270 gpl

2 Agitation air flow rate to reactor I

500 NM3/HR

3 Flocculant solution flow rate

1-2 mg/l 5 mg/l 1 mg/l

4 Crude brine pH 9.5 10.5 95 Water seal layer

temperature of clarifier (V.112)

Ambient Ambient + 15 Deg.C

-

CHEMICAL PREPARATION

6 Agitation air flow to V.114 A/B

50 NM3/hr 100 NM3/hr -

7 Agitation air flow to V.116 A/B

50 NM3/hr 100 NM3/hr -

8 Agitation air flow to V.117 A/B

50 NM3/hr 100 NM3/hr -

PRIMARY BRINE FILTRATION

9 Clarified brine tank level

70% 80% 40%

10 Filtered brine tank level

70% 80% 40%

11 Clarified brine flow rate to

anthracite filters

74 M3/hr 80 M3/hr -

12 Brine flow rate to individual

anthracite filters

37 M3/hr 45 M3/hr -

13 Differential pressure across the

anthracite filters

0.5 ksc 1.5 ksc -

14 Turbidity of filtered brine

Less than 10 ppm

10 ppm -

Page 9: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.1.1 ANTHRACITE FILTERS

The clarified brine from is fed to the primary brine filters to reduce suspended solids content in brine to les than 10 ppm. Out of three filters, two will be working in parallel and one will remain as stand by.

Anthracite is used as filtering medium. The filtered brine is collected in a filtered brine tank. During the operation, when one filter becomes saturated, the pressure drop across it increases. The differential pressure across the anthracite filters is monitored by individual differential pressure indicators. when the pressure drop across the filter increases then the stand by filter is taken in line and the saturated filter undergoes backwashing. Filtered brine sent from using the backwash pump is used for backwashing.

Backwashing carried out in 3 steps:

1) Surface washing 2) Backwashing3) Resetting (preparation )

Step -1: SURFACE WASHING:

This is provided to loosen the sludge cake at the surface of filter medium.

Step -2: BACKWASHING:

During backwashing, the filtered brine is introduced from the bottom of the filter and all the precipitators trapped in the filter medium are removed and sent to the recovered brine pit.

Step -3: RESETTING: (Preparation)

After the backwashing step, the clarity of filter outlet is established by passing the filtered brine from top to bottom of filter (resetting) for a small duration.

All the steps are carried out either automatically from the DCS or manually from local control station. The selection of the operation shall be through a local/auto selection from DCS. This local/auto selection shall be done by the engineers on the DCS panel.

During each stage of regeneration steps, step break provision is provided to stop the operation. Unless the step break step is activated, the operation goes to the next step automatically, by pass provision also provided for each step of operation. In case of malfunctioning of any value, mishap alarm appears, indicating valve malfunctioning.

Page 10: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Table 2 (b) Valve Opening Time

STEP VALVE OPENING TIME FLOW RATE

1. SURFACE WASHING XC 123 5 MIN 40 M3/HR XC 125

2. BACKWASHING XC 121 15 MIN 80 M3/HR XC 125

3. RESETTING XC 126 5 MIN 40 M3/HR XC 124

4. NORMAL RUNNING XC 127 --- 37 m3/hr XC 122 (MAX 40 m3/hr /filter)

VALUE DETAILS

1) XC 121 Backwash inlet (6”)2) XC 122 Running outlet (4”)3) XC 123 Surface wash inlet (4”)4) XC 124 Preparation outlet (4”)5) XC 125 Backwash outlet (6”)6) XC 126 Preapration inlet (4”)7) XC 127 Running inlet (4”)

Table 2 (c) Quantity of Anhtracite in each filter and size distribution

Size (mm) Height (cm) Cu.m Top 0.6 - 1.2 600 4.6

3.0 – 4.0 75 0.555.0 – 10.0 100 0.7311.0 – 15.0 100 0.7316.0 – 30.0 130 0.94

Bottom 4.0 – 50.0 630 2.70

Page 11: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.1.2 PRECOAT FILTERS

The filtered brine from is fed to the polishing filters to reduce suspended solids to less than 0.5 ppm. This is a candle type precoat filter. Two such filters are provided – one operating and while the remaining one stays in stand by mode after backwashing.

The polished brine after adjusting the pH to 9 after adding 32 wt% HCl is sent to the polished brine storage tank. DM water is added to the 32 % HCl in small quantities to prevent crystallization of brine at the point of entry of HCl.

The pH is adjusted to 9 to facilitate converting all the suspended impurities to their ionic forms (chelate resins can absorb only the ionic impurities).

Each operating filter is a cylindrical vessel MS rubber lined. Inside this vessel, a perforated plate having 73 holes is provided in the upper portion of the vessel. Carbon filter candles are suspended from the holes of the perforated plate. Each candle has 3 carbo elements. Total no. of elements present is 219 in each filter.

The filter elements used in this unit are porous cylinders SCHUMACHER “CARBO 40”. This material is composed of pure carbon with an average pore size of 110 micron.

The filter aid used is - Alpha cellulose (BWW 40)

FILTERATION

Filtration cycle : Pressure drop : 2 Kg/cm2 (max.) Operating time: 48 Hrs

Whatever expires first i.e., pressure drop exceeds 2 kg/cm2 or operating time 48 hrs filter is isolated.

Filtration area 41 m2Design temp. 80 Deg.CDesign pressure 5 kg/cm2Capacity 80 m3/hr (normal)

SPECIFICATION OF INLET BRINE

Fluid : Saturated NaCl BrineFlow rate : 80 m3/hr (normal)

Page 12: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

COMPOSITION OF BRINE

NaCl -- 300 – 310 g/lNaClO3 -- 20 g/l (max.)Na2SO4 -- 5 g/l (max.)Na2CO3 -- 300 mg/l (max.)NaOH -- 300 mg/l (max.)CaCO3 and Mg(OH)2 -- 5 mg/l (max.)Cl2 (free chlorine) -- 0

BaSO4 has to be prevented as it can lead to the clogging of the carbo-cylinders.

Density - 1.190 kg/m3pH – value - 9.5 – 11Temperature - (max.) 70 Deg.CSuspended solids - normal 5.0 mg/l

(max.) 10.0 mg/l

QUALTIY OF POLISHED BRINE

Suspended solids: Less than 1 mg/l suspended solids in the treated brine.

Page 13: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

SUMMARY OF OPERATION

The operation can be divided into 4 steps.

I Preparation of precoat/body feed II Precoat III Filtration IV Washing

I PREPARATION OF PRECOAT

The precoat tank (V.142) is filled with polished brine up to 80%. The required alpha cellulose (41 kgs) is added. Start the agitator (A.142) and run it for 10 min.

MIXING BY CIRCULATION

The mixing aims to make a uniform alpha cellulose concentration in the precoat tank and filter vessel. The precoat suspension from the precoat tank (V.142) is sent to the filter vessel using precoat pump (P.142), through three air vent valves (V.9, V.10, V.11) at the upstream side of the filter. The brine liquid is circulated back to the precoat tank. Precoat pump (P.142) discharge flow rate is kept 103 m3/hr.

II PRECOATING

In precoating the precoat layer is formed on the surface of the filter elements. In order to do this, the precoat outlet valve (V.15) is opened (after completion of precoat mixing by circulation) and then the upstream air vent valves V.9, V.10, V.11 are closed. Precoat tank level is monitored. The precoat suspension is pushed from the outside to the inside through the filter elements and is returned to the precoat tank.

The filter aid (alpha cellulose) deposits on the surface of the filter elements. Precoat layer formed. The precoat layer contributes to achieve a fine filtration quality by preventing filter elements from blinding.

A FLOW STOP OR A SUDDEN FLOW CHANGE AFTER THIS STEP CAN CAUSE BLINDING OF THE FILTER ELEMENTS

Flow rate changed from precoat (103 m3/hr) to filtration (80 m3/hr) in acceptable time.

III FILTRATION

a) PREFILTRATION: The filtrate recycle valve is opened (V.16). the polished brine which is coming out of the filter is pumped into filtered brine inlet valve V.1 and V.2 (P.121 A/B discharge) opened and V.3 – precoat inlet valve is closed.

Page 14: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The valves V.1, V.2 should be opened and V.3 should be closed slowly and simultaneously. The prefiltration starts when the above mentioned steps are carried out.The prefiltration i.e., the circulation of brine between filter and filtered brine tank, is intended to secure full and fine filtration efficiency.

Flow rate of brine is changed by control valve (V.5). Setting of flow: 80 m3/hr.

Once the above steps are over, polished brine is sent to polished brine tank (V.143). When the filtered brine has passed through the precoat layer formed on the surface of the filter elements from the upstream side to downstream side, the fine impurities are trapped and removed.The control of filtration process made by

- filtration time (48 hrs) - The differential pressure inlet and outlet of filter vessel (2 kg/cm2)

whichever is earlier.Once a filter is isolated, the next filter should be lined up. Accordingly the stand by filter should be precoated and kept ready for lining up.

b) DOSING BODY FEED SUSPENSION When process has entered precoating, start body feed.

BODY FEED METHOD

Body feed method is one for mixing filtered brine feed with alpha cellulose by body feed pump. The body feed suspension is filtered together with filtered brine. This method gives advantages to prevent filter elements from blinding and to extend the filteration time.

IV WASHING

Normally the washing process is carried out four times. The washing steps to be made each time are as follows:

The upstream air vent valves V.9, V.10, V.11 are mounted below the perforated plate at 120 Deg. gap around the vessel. During the over flow through sight glass, open the upstream air vent valves V.9, V.10, V.11 one by one in turn, in order to wash evenly the surface under the perforated plate.

Page 15: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Table 3 VALVE DETAILS

V 1 Filtered brine inlet isolation (Manual)

V 2 Filtered brine inlet actuated type (ON/OFF)

V 3 Precoat inlet

V 4 Mud discharge (Backwash outlet)

V 5 Inlet flow control valve

V 6 Downstream air vent valve

V 7 Plant air inlet isolation valve

V 8 NRV Plant air

V 9 Upstream air vent valve

V 10 Upstream air vent valve

V 11 Upstream air vent valve

V 12 Filter outlet to V.143 polished brine tank (ON/OFF)

V 13 Outlet isolation valve (manual)

V 14 Backwash inlet (or) washing brine inlet

V 15 Precoat outlet

V 16 Recycle to V.121

V 17 Precoat outlet, air vent overflow to sludge

V 18 Filtered brine to Body feed tank filling

V 19 Precoat recycle to V.142 isolation

V 20 Precoat recycle to V.142 (ON/OFF)

V 21 Backwash pump discharge to V.142 filling

Page 16: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Table 4 location and operating range of filters and accessoriesNo. Item Location Standard Upper limit Lower limit

PARAMETERS

SECONDARY BRINE FILTRATION

1. Brine flow rate to polishingFilter

FIC-140 A/B 74 m3/hr 80 m3/hr

2. Differential pressure acrosspolishing filter

PDI-140 A/B Less than 2 kg/cm2

2 kg/cm2

3. Polished brine tank level

LIA-143 70% 80% 40

4. Polished brine pH

AICA-141 9 10 8

5. SS in polished brine

Less than 0.5 ppmppm

LessThan

0.5 ppm

6. Body feed flow rate

P-141 A/B

SECONDARY BRINE PURIFICATION

7. Polished brine temperature

TICA-151 60 Deg.C 65 Deg.C 55

Page 17: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

8. Polished brine flow rate toChelate resin tower

FIA-151 74 m3/hr 80 m3/hr

9. Super purified brine pH

AIC-151 4 5

10. Super purified brine hardness(Ca & Mg)

AI-152 Less than20 ppb as

Ca

20 ppb as Ca

11. Super purified brine hardness(Sr)

SampleAnalysis

Less than100 ppb as

Sr

100 ppb as Sr

Page 18: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.2 Secondary Brine Purification Unit

The secondary brine unit consists of two chelate resin towers. The tower is a cylindrical MS rubber lined vessel having a perforated plate in the lower portion of the vessel. Around 264 nos. of strainers are fitted in the perforated plate. The strainers are made up of PPO (Poly phenylene oxide). Four cubic meter of DIOION-r-II is kept filled over the strainers. The height of the resin will be around 1.43 mts from the perforated plate. Brine inlet distribution consists of four poly propylene pipes fitted at the top dish end. HCL injection distribution pipe made up of poly propylene wrapped by poly propylene cloth is fitted just above the resin surface. There are 3 sight glasses fitted in the resin tower vessel. This will indicate the resin level during the various stages of regeneration. The resin level during HCL injection will be in the lower most level due to shrinkage of resin. After the second backwash step, the resin level will be in the top sight glass level, due to expansion of the resin particles.

The polished brine after adjusting the temperature to 60 Deg.C is sent to the CHELATE resin columns. Temperature of polished brine to Chelate resin columns is controlled by regulating LP steam flow rate to polished brine heater (E.151). in the chelate resin columns, the hardness of brine is reduced to less than 20 ppb by absorption with chelate resin. Two columns are provided in series and are operated in a merry go round mode.

The two ion exchange vessels are normally operated in series while in service. The brine solution passes from one ion exchange vessel (primary) to the second ion exchange vessel (secondary). When the ion exchange resin in the primary vessel is exhausted the primary vessel is passed and total brine flow diverted to the secondary vessel. The primary vessel is then regenerated. After regeneration, the brine flow is again diverted to pass through the regenerated vessel, which is taken back in service as secondary ion exchanger.

When the hardness at the outlet of the first resin column in the series reaches more than 100 ppb or 24 hrs service (whichever is earlier) it is isolated for regeneration.

REGENERATION INVLOVES FOLLOWING MAJOR STEPS:

1 BACKWASH: DM water is introduced from the bottom of the chelate resin column to make the resin loose and remove any suspended solids or broken resin to outside the column.

2 ELIMINATION BY HCL: HCl diluted to about 4 wt% is fed to the column at its top exposure of the entire resin to the acid causes exchange of all the hardness and heavy metals with H+ ions. After the elimination any excess of HCl in the column is washed out with DM water.

3 REPLACEMENT OF H+ WITH Na+ BY NaOH: Sodium hydroxide diluted to about 5 wt% is introduced from the bottom of the resin column. Exposure of the entire resin to NaOH causes exchange of H+ ion with Na+ ions. After the replacement, any excess NaOH is washed out with DM water.

4 BRINE REPLACEMENT: Before the chelate resin column (T.151 A/B) is put into operation the fluid in the column is replaced with secondary brine.

Page 19: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The regenerated resin is put into service as secondary column in the series. All the secondary brine purification plant operations are carried out automatically by a PLC. However, it is interfaced with a DCS for indications.

EFFLUENT: The effluent generated during the backwashing which is acidic in nature are collected in a waste water pit (V.152) neutralized with NaOH and pumped to the main effluent treatment plant using waste water pumps (P.152 A/B0. the total quantity of effluents generated per regeneration is approx. 65 cu.m.

Table 5 Parameters of Secondary Brine (Resin Tower Outlet)

NaCl 300-310 gplCa & Mg Less than 20 gpl

Sr 0.06 ppmSiO2 4ppmpH 9.0

Temperature Around 60 deg. CSuspended solids 1 ppm

Ba 0.4 5 gplNaClO3 20 gplNa2SO4 5 gpl

I 0.2 ppmAl 0.1 ppmFe 0.2 ppmMn 0.2 ppmNi 0.01 ppm

Total organic content (TOC) 10 ppm

Page 20: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

TIC

PIC

HC

Feed Brine Pump

LIC

LIC

DepletedBrine Tank

To ChlorineSection

Polished BrineHeater

AIC

Polished Brine Pump

LIC

Chelate ResinTower

Secondary Brine Tank

SuperPurifiedBrine Head

Electrolyzer

AIC

DepletedBrine Pump

DechlorinatedBrine Tank

To Cl2 First Cooler

TIC

Vacuum PumpDrain Separator

Recovered Cl2 Cooler 10% Na2CO3

Saturator

20% NaOH

pH

Dechlorinised Brine Pump

By Pass

AIC

Brine Dechlorination

Tower

Fig 2 Secondary Brine Treatment & Dechlorination

Page 21: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.2.2 Depleted Brine Dechlorination Section

To carry out effective dechlorination, chlorinated brine of which the pH is 4-5 under normal operating conditions is acidified to a pH of about 2 by adding 32 wt% HCl in the line before entering the depleted tank. The acid addition under automatic pH control drives the hydrolysis reaction to the left.

Cl2 + H2O ---------- HOCl +HCl

Most of the free chlorine exceeding the equilibrium solubility under acidic brine conditions escapes to the main chlorine gas header.The brine is then sent to the dechlorination tower. In the dechlorination tower, operated at about 230 torr vacuum by a dechlorination vacuum pump, free chlorine is stripped from the chlorinated brine by lowering the chlorine gas equilibrium partial pressure. At the tower outlet, the active chlorine content in the brine will be as low as 20 ppm. This dechlorinated brine after the tower outlet is called “lean brine”. The dechlorinated brine is collected in a dechlorinated brine tank. The condensate collected from the hydrogen gas cooler is also added in this tank.The lean brine is neutralized with 209 wt% NaOH to a pH of 8. The 10wt% Na2SO3 solution is added to the lean brine to eliminate the active chlorine content completely according to the following reaction.

NaClO + Na2SO3 ---------- NaCl + Na2SO4

The élan brine with no active chlorine is then sent to the saturators for further saturation with the raw salt. A part of the lean brine is purged out to maintain the chlorate level (NaClO3) less than 27 gpl.The 10 wt% Na2SO3 solution is prepared by dissolving Na2SO3 powder in DM water. Two tanks are provided for preparation and supply of Na2SO3 solution. The solution is supplied to the lean brine using metering pumps. The HCl required for acidification of brine is collected in the HCl day tank and supplied to various users by HCl feed pump. To ensure the availability of HCl to all users, one pressure control system is provided in the HCl supply ring.The free chlorine removed from the depleted brine at the dechlorination tower is sucked by a vacuum pump through recovered chlorine coolers. In recovered chlorine coolers, the chlorine gas is cooled to about 50 deg C to reduce its volume. The condensate is returned to depleted brine tank.The vacuum system consists of two liquid ring vacuum pumps (one working and the other standby) one gas separator and one cooler. The cooled chlorine gas from the recovered chlorine gas cooler is sucked by vacuum pump under a controlled pressure of about 230 torr and then sent at a slightly negative pressure to wet chlorine gas main header for further treatment.

NOTE: If alkaline brine comes in contact with ceramic packing inside the vacuum tower, it will pick up silica from it which is not desirable for membrane cell operation.

Page 22: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Na2SO3 Addition.It is recommended to add 10 wt% Na2SO3 solution in the line two times the quantity required for treating the chlorine in dechlorinated brine.Flow rate of 10 wt% Na2SO3 solution is calculated as follows.

Vss = 0.0346 X CNaClO X Vdb

Vss : actual flow rate of 10 wt % Na2SO3 solution (l/h)CNaClO : NaClO concentration in dechlorinated brine after vacuum dechlorination (ppm)Vdb : dechlorinated brine flow rate

Depleted brine composition

NaCl -- 200-220 gplNa2SO4 -- less than 10 gplNaClO3 -- less than 27 gplTemperature -- 80-90 deg CFlow rate -- 58 m3/hr

Chlorate removal system

Chlorate is an undesirable by-product in the electrolyzers; the production rate is subjected to the current efficiency level of the electrolyzers in the operation.A build up of NaClO3 level in the brine loop towers the NaCl saturation limit because the solubility of NaClO3 is higher than that of NaCl and can increase the NaClO3 content in the product caustic. Therefore the NaClO3 level in the feed brine is generally maintained at 10 5 g/l. in order to maintain this level, periodically brine will be purged from dechlorinated brine pump discharge to sea disposal.

Page 23: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.3 Electrolyzer

BASIC PRINCIPLE

NaOH is produced by the following principle.

Electrochemical reaction in an Ion-Exchange-Membrane Electrolyzer by utilization of super purified brine.

Sodium chloride is dissolved in the brine solution in the anode compartment according to the following equation.

NaCl Na+ + Cl-

The principal anodic reaction involves oxidation of the anion Cl- to produce gaseous chlorine

2Cl- Cl2 + 2e-

The cation Na+ in the anode compartment is transferred with water to the cathode compartment through the ion-exchange – membrane. Water is electrolyzed in the cathode compartment according to the following equation.

2H2O + 2e- 2H+ + 2OH- H2 + 2OH-

The primary cathodic reaction is the reduction of the cation H+ to produce gaseous H2 and to regenerate hydroxyl ions.The sodium cation Na+ combines with OH- to form NaOH

Na+ + OH- NaOH

Overall electrochemical reaction

2NaCl + 2H2O 2NaOH + Cl2 + H2

Demineralised water is fed in recycle NaOH line in order to regulate the NaOH strength in cathode compartment. Depleted brine is discharged with chlorine from the anode compartment. Caustic soda produced in the cathode compartment is discharged with hydrogen from cathode compartment.

Recycled caustic diluted with DM water is fed into the cathode compartment.

REACTIONS AND SIDE REACTIONS

Page 24: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Reaction in the cathode chamberThe main reaction on the cathode surface is H2O reduction.

H2O + e- ½ H2 (g) + OH- --- (1)

1/F mol of OH- is generated in the cathode side and (1/EK) mol of OH - is back migrated to the anode side through the ion exchange membrane where EK is a current efficiency in the cathode side.

Reaction in the anode chamber

The main reaction on the anode surface is Cl- oxidation i.e.

Cl- ½ Cl2 (g) + e- --- (2)

The electrochemical side reaction is O2 (g) generation by H2O oxidation i.e.

H2O ½ O2 (g) + 2H+ +2e- --- (30

The first chemical side reaction in chlorine dissolution without dissociation according to the equation 4

Cl2 (g) Cl2 (aq) --- (4)

The second chemical side reaction is free chlorine dissolution in water according to equation 5

Cl2 (aq) + H2O HOCl (aq) + H+ + Cl- --- (5)

The third chemical side reaction is dissociation with the hypochlorus acid, HOCl according to the equation 6

HOCl (aq) + OCl- OCl- + H+ --- (6)

The fourth chemical side reaction is CLO3- generation according to the equation 7

2HOCl (aq) + OCl- ClO3 + 2H+ + 2Cl- --- (7)

The fifth chemical side reaction is neutralization between H+ ions generated by the side reactions (eq. 3, 5, 6 & 7) and OH- ions back migrated from the cathode side i.e.

H+ + OH- H2O --- (8)

The sixth chemical side reaction is neutralization between H+ ions and Na2CO3 and NaHCO3 in the feed brine according to the following reactions.Na2CO3 + 2HCl 2NaCl + H2O + CO2

Page 25: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

NaHCO3 + HCl NaCl + H2O + CO2

SPECIFICATION

1 Type: DCM 405 x 22 No. of unit cells: 5 x 23 Anode effective area : 15.15 M2 x 24 Anode : DSA5 Cathode : Activated cathode6 Rated current : 54.24 KA7 Current density : 3.29 KA/m2 (rated : 3.59)8 Cell voltage : 3.18 V9 Dimensions : 2560 W x 1360 H x 1058 L10 Weight (empty) -- 4.9 mt11 Weight (operating) -- 7.4 mt12 Cathode current efficiency : 95.5 %13 Power consumption at rectifier terminal : 2250

(DC KWH/metric ton of NaOH)14 Caustic conc. : 32.5 %15 Cell operation temp: 90 C (Max.)16 Life of anode coating: 8 yrs (min)17 Life of cathode coating : 8 yrs (min)18 Membrane and gasket life ; 4 yrs (min)

STRUCTURE

The DCM 405 x 2 consists of DAM – 405 monopolar electrolyzers, i.e., two DCM – 405 are combined with one set of tie rods structurally and connected electrically in series with one set of under cell bus bars. An insulation element is positioned between DCM – 405 electrolyzers.

Each DCM – 405 is electrochemically divided into 5 unit cells and structurally consists of 2 anode elements, 1 half anode element, 2 cathode elements, one half cathode elements and between the elements membranes are positioned.

CIRCUIT OF ELECTRIC CURRENT

The electric current flow for each electrolyzer is as under.

The Electric current from the positive side of the rectifier flows through 8 under cell bus bars and enters into each anode element of the first set of DCM 405 x 2 twin electrolyzer.

Then it flows to the cathode element through ion exchange membrane and to the under cell bus bars.

Page 26: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

From the under cell bus bars, the current, flows to the anode element, of the second half of DCM 405 x 2. There it follows similar current path as in the case of first half and goes to the next electrolyzer through inter cell bus bars.

Finally from the cathode side of the last electrolyzer, current flows back to the negative terminal of rectifier.

PROCESS DESCRIPTION

1 Electrolyzer circuitThe electrolyzer circuit has 44 no.s of DCM 405 x 2 electrolyzers and a rectifier unit.The circuit is arranged in two rows. Both rows are connected to the rectifier unit with power supply bars and one row is connected to the other with cross over bus bars at the opposite side of the rectifier unit. Each electrolyzer in a row is connected with each other through inter cell bus bars.

2 Fluid stream (Super purified brine)Super purified brine from the brine treatment section is fed into the feed brine manifold of each DCM 405 X 2 electrolyzer through a header pipe and each branch pipe. Brine is distributed to each anode chamber. A restriction orifice is provided at the inlet of each anode chamber respectively. Brine flow rate to each DCM 405 X 2 electrolyzer is adjusted by a brine flow gauge mounted on each branch pipe.

3 Anode chamberSuper purified brine fed into anode chamber is decomposed electrically into Cl- and Na+ by direct current in the anode chamber.

The Cl- ions are oxidized at the anode surface and from chlorine gas. Depleted brine and wet chlorine gas at 80 – 90 C form a two phase system and overflow out of the anode chamber.

The two phase flows from each anode chamber and are collected into the manifold of each electrolyzer and flows by gravity into depleted brine tank (V.201) from the depleted brine tank chlorine gas goes to chlorine gas treatment section and depleted brine pumped to brine treatment section.

Reaction:Sodium chloride is dissociated in brine solution in the anode compartment according to the following equation:

NaCl Na+ + Cl-

Principle of anodic reaction involves oxidation of the anion Cl-

2Cl- Cl2 + 2e-

Page 27: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The sodium ions in the anode chamber pass through the membrane and enter into the cathode chamber together with water.

Cathode chamber

In the cathode chamber water is decomposed electrolytically into H+ and OH- by direct current.The H+ ions are reduced on the cathode surface and form Hydrogen gas. The OH- ions combine with Na+ ions and form caustic soda. The two phase stream of NaOH + H 2 at 80-90 Deg.C overflows out of each cathode chamber and are collected into the manifold; they flow by gravity to NaOH circulation tank (V.202).

From the NaOH circulation tank, Hydrogen gas and NaOH separated. Hydrogen gas goes to the Hydrogen circulation pump (P.202 A/B). This caustic soda is separated into two streams.

a) 32.5 wt% caustic head tank for conc. In Mercury cell up to 48%.b) Recycle NaOH to the electrolyzer.

Recycled caustic is fed to the recycle caustic manifold of each DCM 405 X 2 electrolyzer through a header pipe and each branch pipe and distributed to each cathode chamber. Caustic flow gauge mounted on each branch pipe is used for adjusting the caustic flow rate to each electrolyzer.The caustic strength is generally kept about 32.5 wt% at the outlet of the electrolyzer by controlling feed quantity of DM water which is added into the recycle caustic stream.

CAUSTIC SODA HEAT EXCHANGERA caustic soda heat exchanger is installed in the recycled caustic steam to control electrolysis temperature by cooling down or by heating up. This heat exchanger functions as a heater to warm up the electrolyte in the electrolyzer during the plant startup. As the membranes become colder and the electrolyzers become less energy efficient due to increase in cell voltage, this heat exchanger functions as a cooler.The gas pressure control in the anode and the cathode chambers are very important for stable electrolyzer operation. The hydrogen gas pressure is controlled to avoid membrane rubbing with the rough cathode surface leading to membrane damage. A differential pressure indicator is provided in the main header to monitor the differential pressure between both chambers. In case of large surge in gas pressure, the interlock system will work to protect the electrolyzers. Moreover a hydrogen gas vent stack is installed top protect the circuit against extremely high pressures of the hydrogen gas and two chlorine gas seal pots against extremely high/low pressures of chlorine gas respectively. The hydrogen vent stack is also used to vent hydrogen gas to atmosphere during startup.

Page 28: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Operating conditions for electrolyzer

1. Current increase and decrease.Sudden current load change will abruptly affect the bubbling ratio in electrolyte and could cause the overflow stream to sprout or stop. Also membrane vibration due to gas pressure fluctuation and the membrane exposure to pressure zone will shorten the membrane life. Therefore the current load should be increased or decreased only gradually at the rate of 1 KA/min.

2. Feed brine flow ratea) Current load increase. Before increasing the current load, the feed brine flow rate is

increased to the value corresponding to the projected current load.b) Current load decrease. The current load is decreased before decreasing the feed brine

flow rate to the projected current load.

In either case of increase/decrease in current load, the NaCl strength in depleted brine is analyzed and checked if it is more than 180 gpl in order to prevent membrane damage.

3. DM Water supply rate.

The DM water supply rate to the recycled caustic soda will be controlled to maintain the caustic soda strength in the catholytic constant.

a) Current feed increase. Before increasing the current, the DM water flow rate to the valve corresponding to the projected current load is increased.

b) Current load decrease. The current load is decreased before decreasing the DM water flow rate corresponding to the projected current load.

Page 29: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.4.1 Caustic Evaporation Plant

The purpose of the plant is to concentrate the 32% caustic coming out of the electrolyzers to 48% caustic lye. This concentration is achieved by three multi effect evaporators. These evaporators concentrate the 32% caustic to 36%, 41% and eventually 48% caustic lye. Multi effect evaporators are usually fed by 3 possible feed systems:

1. Forward feed system: where feed and the heating medium both enter the first evaporator, in other words, co-currently.

2. Backward feed system: In this system the feed enters counter-currently with respect to the heating medium.

3. Mixed feed system: In this feed system the feed enters from the first evaporator, and the fresh heating medium may be introduced anywhere between the evaporators.

The caustic evaporation plant at TPL employs the backward feed system. The evaporators are shell and tube type. The caustic flows in the tube side and steam circulates on the shell side. Glass wool insulated steel lines are used for circulation of steam. The caustic is carried in stainless steel lines up to a concentration of 36%, after which glass wool insulated Titanium lines are used for it. Steam is used as the heating medium. 32% caustic from the electrolyzers is preheated to 90 C by the 48% caustic coming out of the CEP plant. Steam coming from 2nd evaporator is fed into the 1st one, and caustic is concentrated to 36%. It is sent to a vapor separator, which is connected to a steam ejector, which separates the vapors from the caustic which are cooled and sent for recovery.

The vapors separated from the 3rd evaporator are used to pre-heat the 36% caustic before it enters the 2nd evaporator; it is heated up to 110 C. Out coming steam from the 3rd evaporator is circulated inside the 2nd one and the caustic is concentrated to 41%, and the temperature to 120 C. The vapor is separated and the used up steam is re-used in the 1st evaporator.

The steam and caustic from the 3rd evaporator pre-heat the 41% caustic to 160 C for more efficient concentration. Fresh steam enters the evaporator and concentrates the caustic to 48% caustic lye. The out coming caustic is cooled down by using its heat to pre heat the caustic feeds to the other evaporators. It is finally cooled by cooling water lines to 45 C caustic lye. This is either sold as a product or sent for further concentration in the fusion plant.

Page 30: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Cold water In

Water Out

EVI

EVII

EVIII

Steam Ejector

Condensate to BH

Vapor Separator

ToRecovery

Vapor Separator

Vapor Separator

Pump

Heat Exchangers Heat

Exchangers

Pump

Pump

Pump

32%Fresh Caustic

Heat Exchangers

32% NaOH, 90C

36%NaOH100 C

36% NaOH, 110 C

41%NaOH120 C

41% NaOH, 160 C

48% NaOH, 180 C

48% NaOH, 100 C

41%NaOH,45 C

(Product)

SteamInlet

IntWaterTank

Fig 3 Caustic Evaporation Plant (CEP)

Page 31: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

2.4.2 Fusion Plant

The purpose of this plant is to concentrate the 48% caustic from the CEP plant to 98% Caustic flakes.

The plant consists of three different multi effect evaporators. The temperature of the caustic goes as high as 420 C in this plant. Normal steel apparatus may get corroded in such a highly alkaline and hot environment. Hence all lines and inner lining of the equipments are made up of Nickel. The plant consists of:

1. Pre-Concentrator (PC)2. Rising Film Evaporator (RFE)3. Falling Film/Final Evaporator (FFE)

48% caustic liquor is fed by pump to the PC from top, operating on the product side under a pressure of approximately 65 torr (87 mbar). During a single pass through the PC, the caustic is concentrated up to approximately 55.4-55% caustic.

The PC is heated by the vapors coming out of FFE.Before entering PC, a 5% sugar solution is added to the caustic. Sugar acts as a

corrosion inhibitor. This forms a layer of Nickel oxide on the lines. This layer prevents further oxidation of Ni. The quantity of sugar to be added will be adjusted to the plant capacity each time. The NaOH 55% pump conveys the dilute acid to the pre heater at about 90 C.

The pre-concentrated caustic liquor is passed through a double tube type heat exchanger heated by condensed steam off the RFE. The outlet NaOH temperature is about 140-145 C. when passing the steam heated RFE, caustic soda is concentrated under a pressure of approximately 200 torr (267 mbar) up to 76% NaOH.

The 76% caustic leaving the RFE is dipped into barometric seal pot. The PC and the RFE work under vacuum, which in both cases is produced by the vacuum ejector pump.

The vacuum of 65 torr is required for the PC is produced by the 3 step injection group. The vapors from the PC are condensed in the mixing condenser via a barometric dipping tube. The condensed vapors and he cooling water are carried in to the waste water pit. For the RFE, a vacuum of 200 torr is produced by the 2 step injection group.

The 76% NaOH pump carried the caustic soda to the molten salt heated FC, where it is evaporated under normal pressure up to a min of 98.5%Naoh. The distributing device is fixed to the lower part of the separator and by this device; the caustic soda can be switched to either placer or drum filling station.

In order to exclude atmospheric oxygen from penetrating into the system and to avoid corrosion the distributing system is superposed with nitrogen. The filling tubes to the flaker and to the drum filling station have been provided with a molten salt heating and the tube for NaOH 55-76% with steam heating.

Page 32: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The well cooled flakes are then filled into 50 kg bags by means of the bagging scale. The balance to the nominal capacity of 100 tpd (37-20, maximum 50 tpd) of caustic melt can be fed via existing distributing devices to the drum filling unit.

Control High Pressure Steam and Condensate System.RFE is heated with high pressure steam concentration of the leaving NaOH solution

is determined by it outlet temperature, therefore a thermometer is installed in the outlet tube. Above the temperature controller TIC, the temperature of 160 C is adjusted which corresponds to the concentration of NaOH to 76% at 200 torr.

From there corresponding command variable is given to the steam pressure control valve TCV in the steam tube, thus increasing or diminishing the steam throughput. The steam leaves RFE at the lower end. A level transmitter LT built in keeps the condensate which is under pressure constantly on a certain level. Control valve LCV is arranged in the flow direction after following caustic pre heater and receives its command variable from level control LIC.

This arrangement guarantees an effective heat transfer in rising film evaporator and exploitation of the condensate cooling in the caustic pre heater.

Design DescriptionThe dehydration line consists of the following three stages:

1. Preconcentrator.It is designed as a tube bundle FFE. In the concentration head, the caustic solution is

distributed as follows.Above the tube plate, concentration tubes are provided with vertical slits through

which caustic solution flows evenly through the tubes and down the inside surface of the tubes forming an unbroken film along the inside wall. The PC works at 65 torr vacuum on product side.

The vacuum is produced by steam ejector vacuum pump. The PC caustic leaves the PC at 55% concentration and reaches the vapor separator installed beneath the PC. The vapors produced in the PC are removed by the vacuum pumps and leave the PC through a demister consisting of very fine nickel wire meshing which permits the separation of even the smallest caustic droplets carried along by the vapor. In the subsequent mixing condenser the vapors are condensed.

The PC is heated with vapors from the FC.

2. Rising Film Evaporator.The caustic enters the lower part of the RFE with concentration of NAOH at 55% fills

it up and distributes into the individual tubes of the tube bundle. The rising film evaporator is on the product side under a vacuum of 200 torr.

Heating is done with steam in reverse direction, i.e. the steam entrance is located at the upper part of the tube bundle and the condensate leaves the lower part.The NaOH solution to be evaporated thus enters the tubes at the bottom surrounded by steam.

Due to condensation enthalpy of the steam set free, the evaporation process in the tubes is initiated and the liquid rises to the top according to the air lift pump principle, or

Page 33: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

is driven through the tubes by the existing vapor respectively. The liquid/steam mixture reaches the vapor chamber which is located directly above the tube bundle.

Immediately above the upper plate, a buffer plate is mounted acting as a liquid separator. By exploitation of the different densities of both the phases, here an intense liquid separation is achieved. The remaining liquid evaporated to the desired concentration is collected in the area around the upper tube bottom and leaves through a nozzle.

The vapors deviated at the baffle plate reach the demister made of fine nickel wire meshing. Caustic droplets carried along are separated by this knitmesh and drop back into the liquid collecting chamber. The vapors leave the vapor room and reach the mixing condenser via a duct, where they’re condensed. The non condensable gases are sucked off by the vacuum pump. The heating or blanketing room of the tube bundle is equipped with a venting nozzle at its upper end. At the lower end there are 2 level control nozzles for the level transmitter.

3. Final Concentrator. It consists of individual tube elements, concentrator tubes and the vapor separator.

The caustic is evaporator in the falling film concentrator at atmospheric pressure by means of heat supplied from outside. The PC caustic is fed to the caustic collector by means of the caustic transfer pump. Causes even distribution to the individual concentrator elements where the caustic forms an unbroken film over the whole inside surface flows from top to bottom. Propeller inserts built into the center of each concentrator tube prevent the caustic film from being blown off the inside wall surface due to rapid evaporation taking place. The water contained in the caustic is evaporated while flowing down the concentrator tube. The caustic film, now with a concentration of 98.5% leaves the concentrator element and is fed by a collecting element to the seal pot.

Each element is provided with an individual heating jacket in which the heat transfer medium flows in the reverse direction to the caustic to be concentrated. The heat transfer medium is fed through these jackets and led off through collection. Each heating jacket is provided with throttle valves on the outlet side which permit even distribution of the heat transfer medium to all concentrated elements.

The collectors of the heating jackets of the individual concentrator elements are provided with steam trace heating, to prevent the heat transfer medium from freezing during start-up. Shortly before heat transfer medium reaches operating temperature steam tracing is turned off and vented. Thus formation of inadmissibly high temperature in the steam tracing system is prevented.

The vapors resulting from evaporation stream, together with the caustic, flow form top to bottom of the concentrator tube. Then flow velocity, together with the effect of the above mentioned propeller inerts, cause the caustic film to adhere to the inside wall surface of the concentrator tube. At the bottom of the concentrator tubes, the vapors flow into the horizontal collection channel which leads them to the separator. Caustic droplets possibly carried along by the vapors are separated by the gravitation at considerably reduced flow velocity.

The vapors roughly clean, then leave the separator through a mattress type demister made of fine nickel wire meshing. This demister offers largest possible surface contacts, greatest number of deflection and still causes the least possible pressure drops. The fine

Page 34: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

mist is transformed into large caustic droplets which due to gravity fall back into the collector and are led together with the concentrated caustic to the caustic outlet nozzle. The vapors now almost completely cleaned are led to the PC which removes their heat.

Sucrose System

All equipment components and piping coming in contact with the concentrated caustic are made up of pure Nickel (low carbon Nickel) because of its corrosion resistance. Oxygen acts highly corrosively, particularly combined with high temperature. Therefore, oxygen must be kept out of the equipment components by all means. If corrosion occurs, oxidized nickel would be there in the caustic melt.

Penetration of atmospheric oxygen into the equipment is prevented by designing the plant as air tight as possible and by additionally blanketing the distributing device of the final concentrator with nitrogen. However, the caustic solution itself brings down the oxygen into the equipment in the form of Sodium Chlorate (NaClO3). This type of oxygen is eliminated by adding sugar solution to the feed caustic as corrosion inhibitor. The sugar solution reacts with NaClO3 to form Na2CO3 which is harmless from the point of view of Ni corrosion.

Depending on the chlorate content of feed caustic and feed quality, granulated sugar is added to the feed as an aqueous solution prior to its entry into the NaOH piping. 0.05 kg of sugar per ton of 100% NaOH is added, whereby the nickel pickup of caustic melt is reduced to about 1 ppm. Food quality granulated sugar is use and pumped into the feed liquor as a 5% aqueous solution before being led to the concentrator. At startups, restarts or during any interruptions in the operation, the nickel pickup drops within 24 hours from startup value (approximately 20-30 ppm) to the operating value.

The sugar solution is prepared in the dissolving vessel together with the condensate coming off the condensate tank resulting in a 5% sugar solution. The complete sugar solution is led into the NaOH piping before the PC by means of a dosing pump.

Molten Salt Heating System

The heating system using molten salt as a heating medium mainly consists of a salt tank and an immersion pump, forced circulation heater with a built in burner, the sir preheater with incorporated fuel gas stack and salt piping system.

Concept of the Heat Transfer Circuit.

The heat transfer salt is molten in the salt tank i.e. kept hot and in liquid phase during interruption of operation. During operation salt is circulated by means of an immersion pump from bottom to top by heating coils of the heaters.

The heat produced by the burner is transferred to the salt circulation in the heater coil. From the heater the molten salt goes to the FC. There it heats up and concentrates the caustic, and is circulated back to the salt tank. A by-pass valve regulates the quantity of molten salt in circulation through FC, permitting a part of salt quantity to be returned directly into the salt tank if required.

Page 35: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The whole salt piping system is arranged such that in case of interruption of operation of salt pump (as in case of power failure) the whole salt contents can freely flow back into the salt tank installed at the lowest point of the plant.Heat Transfer Salt.

The salt used for final concentration is a mixture of three salts :1. KNO3 (53%)2. NaNO2 (40%)3. NaNO3 (7%)

The advantages of using this mixture are: It has excellent heat transfer properties Pressureless operation to 500 C Non-flammable Non-corrosive

The disadvantages of this salt mixture are: It has a high crystallization point.

This is countered by making sure that whole system is heatable and can be easily emptied.

Behavior of heat transfer medium. Provided normal operating conditions, the heat transfer salt can be used for many

years. A certain oxidation of NaNO2 occurs in presence of atmospheric oxygen, causing

a rise in point of crystallization. This is prevented by blanketing the salt tanker with Nitrogen.

In case molten salt is heated over a larger period, (for instance quantity of salt circulating through the heater is insufficient due to faulty operation), the component NaNO2 may decompose to Na2O, O2 and N2, which also lead to higher point of crystallization of the salt mixture. Such conditions are, however, prevented by temperature control of the wall of temperature of the salt heater.

Despite above mentioned precautionary measures, the heat transfer salt has to be regenerated after several years of operation.

Page 36: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

5% SugarSoln

48% NaOH, 50C

55% NaOH,90C

LIC

48%Pump

55%Pump

76%Pump

SaltPump

55% NaOH,150C

Steam

TIC

MixingCondenser

76% NaOH,160C

76% NaOH, 160C

PIC

MoltenSalt,420C

Oil

H2 Air

Seal Pot

Steam, 330C

UsedSalt,390C

Salt Tank

Flaker Drum

98% Caustic Flakes,

45C

Cold Water

Pit

Cold Water

Pit

IntTank

Fig 4 Fusion PLant

Page 37: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 3

Demand, supply and manufacturers in India

In India the chloralkali industry is over 100 years old. Its products, chlorine and caustic soda are two basic chemicals. Chlorine is used for disinfecting drinking water bleaching of textiles and pulp, manufacture of insecticides, pesticides, weedicides, pharmaceuticals, pyro/plastics and refrigerants, industrial solvents, rocket fuels and treatment of cooling water for electricity generation etc. chlorine production in our country in 1995-96 was 1.61 Mn tons. Though it is highly toxic and hazardous, it has become indispensable for mankind.

Caustic soda is used for manufacture of paper and pulp, textiles, soap and detergents, aluminium, rayon /viscoelastic fibre, inorganic chemicals, dyestuffs petroleum refining and pharmaceuticals etc caustic production in our country was 1.308 Mn tons.

There are three basic processes for caustic soda production:1. Diaphragm cell process (1865)2. Mercury cell process (1892)3. Membrane cell process (1970)

Each method represents a different method of keeping the chlorine produced at the anode separate form the hydrogen produces, directly or indirectly at the cathode.

Membrane process has the following advantages over the diaphragm and mercury cell process.

1. 25% lower energy consumption2. Pollution free operation3. Higher production purity4. Easier and more flexible operation5. Lower operation temperature

India is self-sufficient in caustic soda. The present installed capacity is distributed amongst different processes as under.

Table 6 membrane cell capacity as 31.3.2002

Sr. No. Companies Capacity(1000 MTPY)

1. Gujarat Alkalies, Vadodara 1702. Grasim Inds, Nagoda 85.53. Standard Alkalis, Kumool 534. Modi Alkali, Alwar 19.85. Chemfab alkalis, pondicherry 16.56. Century chemicals, kalyan 55.77. Hukumchand jute mills, amlai 15.6

Page 38: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

8. Atul products, valsad 11.29. Shree gopal, yamunanagar 13.210. B&T, balarshah 13.211. Punjab alkalis, naya mangal 3312. Tata chemicals 26.413 Kadakja alkalis, ankleshwar 18.514. Search chemical Indus., Jhagada 16.515. DCM Con solidated, Bharuch 49.5

Indian chloralkali products expect to see caustic soda exports to increase from 90,000 tonne in 2001-02 to 210,000 tonnes onwards to close to 3.5 Mn tonnes/year of new capacity and incremental expansions will be added in 2003-04 will almost double the Indian chloralkali capacity. Live growth in domestic alumina production is one factor that could prompt even higher exports long-term. India has no option but to export 20-25% of the total caustic soda production.

A number of new alumina units are at the planning stage, but it will take some time before they can be counted as secure caustic soda consumers. Another factor pushing up Indian exports of caustic soda stems from the duties charged on the imported technologies. Indian caustic soda manufacturers face power from 95 cent/KWhr, compared with 10-15 cents/KWhr in Saudi Arabia, and 20-25 cents/KWhr in the US.

To compete internationally, Indian producers have switched to membrane cell technology and invested in captive power plant generation to ensure reliable low cost supply. However, the current import of 25% on both membrane cell plant and captive power plant in India made it a little uneconomical to implement both options together.

Page 39: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 4

Line sizing

The chloralkali plant at TPL uses mainly five types of lines in the process; namely 1. Mild Steel Rubber Lined (MSRL) 2. Stainless Steel (SS)3. Fibre Reinforced Plastic4. Titanium lines5. Ni plated or entirely Ni lines.

The first three types can be generally used about anywhere in the process, except for lines transporting high temperature or highly acidic/ corrosive media. The fourth type, i.e., Nickel lines are used wherever the media being transported is highly alkaline caustic or that at a high temperature. Nickel is used for this purpose because of its resistance against high temperature and alkalinity. Titanium lines are used where high strength and certain resistivity towards heat and alkalinity is desired.

The line size, however, varies according to the following factors:1. Type of transported media2. The driving force of the media3. Flow rate of the media

This implies that, for instance, that a media of high viscosity or rich in suspended impurities will require a line a larger diameter. Also, if the media is being transported by a pump, a line of smaller diameter will be favorable. Based on such factors, the size of lines connecting various parts across the plant can be tabulated as follows:

Table 7 (a) Line SizingTransported

mediaLine from Line to Line size, MOC

Primary Brine treatment

DM water DM water Saturator 16’‘, SS

Depleted Brine Depleted brine tank Saturator 16’‘, MSRL

Saturated Brine Saturator Mixing reactor-I 32’‘, SS

16% BaCO3 Barium chloride storage tank

Mixing reactor -I 2’‘, MSRL

10% Na2CO3 Sodium chloride storage tank

Mixing reactor -I 2’‘ MSRL

Page 40: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

26% NaOH Caustic head tank Mixing reactor –II 2’‘ MSRL

Mixing tank outflow Mixing reactor -II Mixing tank 8’‘, MSRL

0.05% Floxin Floxin tanks- I&II Mixing tank 1’‘, MSRL

Mixing tank outflow Mixing tank 2 m to clarifier 16’‘, SS

Rest Open channel

Clarified brine clarifier Clarified brine tank 8’‘ SS

Clarified brine Clarified brine tank Anthracite filters 8’‘ FRP

Filtered brine Anthracite filters Filtered brine tank 8’‘FRP

Filtered brine Filtered brine tank Polishing filters 8’‘ FRP

Body feed (alpha cellulose)

Body feed tank Precoat filters 1’‘ FRP

Na2SO3 Na2SO3 preparation tank

Precoat filters 1’‘ FRP

HCl HCl storage tank Polished brine tank 1’‘ FRP

Polished brine Polished brine tank Secondary Brine treatment

8’‘, FRP(/PVC)

Secondary Brine and Dechlorination

Polished brine Primary brine treatment facility

Polished brine heater 8’‘, FRP

Heated polished brine

Polished brine heater Chelate resin tower 8’’, FRP

Super purified brine Chelate resin tower Secondary brine tank 8’’, FRP

Super purified brine Secondary brine tank Super purified brine head tank

8’’, FRP

Super purified brine Super purified brine head tank

Electrolyzer 8’’, FRP

Depleted brine Electrolyzer Depleted brine tank 8’’, FRP

Recycled caustic Caustic storage tank Electrolyzer 6’’, Ni plated SS

Feed brine Super purified brine head tank

Electrolyzer 8’’, MSRL

Depleted caustic Electrolyzer NaOH drain 18’’, MSRL

H2+32% Caustic Electrolyzer Caustic concentration 15’’, MSRL

Page 41: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

plantDepleted brine Depleted brine tank Brine dechlorination

tank8’’, FRP

10% Na2SO3 Sod. Sulfite Head tank

Dechlorinated brine tank

2’’, MSRL

Table 7 (b) Line Sizing

Caustic Evaporation PlantUpto 36% caustic 2’’, SSAbove 36% caustic 2’’, TiSteam lines 2’’, SS, Glass wool insulatedCooling water lines 2’’, MSRL

Page 42: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 5

Instrumentation

The instruments used in the caustic soda plant work on the following principle.

Flow Control : flow control is done with the help of the “I to P” apparatus. This produces a pneumatic pressure in the tube in accordance with the current that it receives, thereby controlling the amount of fluid that passes through. Other devices used for this purpose are rotameter, control valves etc.

o Mass Flow Meter – Works on the “Caroli’s principle”Caroli’s principle: When the flow of a liquid flowing in a tube varies, the frequently with which it vibrates/shakes, the tube also changes. This change can be used to calculate the mass flow/density of the fluid.

o Electromagnetic flow meter: (Anthracite filters)Principle: electromagnetic plates are kept or either sides of the line, and electromagnetic waves are transmitted. The consequent emf induced varies with the flow rate of the fluid. Hence, the induced emf can be used to indicate the flow rate.

o Oval Meter: This is used for flow metering the oil used as fuel in boilers. This consists of oval leads inside the lines which rotates as the oil flows and their rotations are used to detect the flow rate if oil.

o Rotameter: these are extensively used throughout the plant. A rotameter contains a floating device which stays afloat due to the force of the flowing fluid. The elevation gained by the float is used to predict the flow rate of the fluid. This is used for metering the flow of HCl.

o Critical Control valve. This is a device used to control the flow of a fluid, if it goes above a particular value.

o I to P (Current to Pressure) flow controller: if its current input changes, this device produces a consequent change in pneumatic pressure over that liquid, thereby controlling its flow. It is used in dechlorinised brine tank.

o

Shut Off Valves : These are used to completely stop/restart the flow automatically can be controlled directly from the control room, without manual involvement. It can’t be used to control the flow rate, however, but only to stop/restart.These are used in every line, to stop the flow automatically, say in case of emergencies

o Hydrogen Shut Off Valve: This is used for the supply lines in the boiler. It is equipped with a leak detector which measures pressure of hydrogen on either side

Page 43: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

of valve. If the pressure is same on either side, it indicates no leak. But if the pressure on either side differs, then this is an indication of leak. Similarly, there are oil, and water control valves which work on the same principle.

o Solenoid Valve for Oil Control. It opens and lets the oil inside the burner when relay is received.

o Positioner: used in the Electrolyzer unit and it displays the position of the control valve after it has been operated on.

o Photocensor. This is a special type of control used in the salt heater. Since hydrogen and oil are used as fuel in the heater, it checks the spark generated for ignition. As soon as it’s sensor detects the spark created by the arc, it sends the power in relay, cutting it off and putting it in standby mode.

Level Measurement/Indication.

o Level Indicators: (Indicate the level of the liquid inside a vessel)These work on the Bernoulli’s principle as well, and indicate the level of the fluid inside the vessel under a given pressure.

o Ultrasonic Sensors: transmits ultrasonic waves towards the fluid level and the time lag after which they are received can be used to calculate the level.

o Bubbler System: this simply indicates weather the fluid level is high or low, by measuring the pressure of the gas above it. This is a form of approximate measurement.

o Displacement Type Level Transmitter. This is primarily used in the whole of fusion plant. It consists of a float inside the tube which on moving up/down deflects a “torque-tube” and its consequent displacement displays the level.

Calcium Analyzer : This is used to measure the quantity of Calcium and Magnesium present in brine, right before it enters the membrane cells.

It uses three reagents:1. Potassium Hydroxide2. Ethylene Glycol3. Phenolphthalein

These are mixed with a sample of brine. The mixer contains a magnetic stirrer and is connected to a colorimeter via fiber optic lines. The color of the sample changes on mixing the reagents and the intensity of the change is detected by the colorimeter, to calculate the amounts of calcium and magnesium in ppm. It can be caliberated from time to time using a standard reagent.

Temperature Indication. This is done by the following instruments.o Radiation Temperature Detectors: these are extensively used in the plant, also in

the membrane cells for indication of the temperature of vessel contents. This works on the principle of thermal radiation, that every hot body emits some

Page 44: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

thermal radiation proportional to the fourth power of its temperature, and this instrument uses the intensity of the radiation to indicate the temperature of the body.

o Flame Temperature Measurement: the device consists of a Ultra-violet sensor, which compares the color of the flame with standard colors to determine the temperature. For instance, a flame of higher temperature would be more reddish, sometimes whitish in color, and so on. Naturally, this is used only wherever the temperature of a flame is required to be measured. It has a relatively high range; of up to 3000ºC. it is used in the burner of the fusion plant.

Pressure Indication: o Pressure transmitters: These are diaphragm type pressure transmitters and work

on Bernoulli’s principle, i.e. indicate pressure when height of the liquid in a column is already known.

o Pressure Switch: these are used to measure the pressure of a flowing fluid. Consists of a diaphragm or a metal sheet lodged inside the line. A switch is placed in the direction opposite to the flow. As the fluid slows, it exerts some pressure on the diaphragm or the metal sheet, which pushes the switch that it is in contact with. The switch displays the pressure it has received.

Following table shows a list of the instruments, their range and accuracy for the primary brine treatment section of the plant.

Table 8 InstrumentationSr No. Description Range Accuracy1 POLISHED BRINE

pH0-14 pH ±0.2 pH

2 FEED BRINE pH 0-14 pH ±0.2 pH3 EFFLUENT pH 0-14 pH ±0.2 pH4 DECHLORINATED

BRINE pH0-14 pH ±0.2 pH

5 SATURATED BRINE DENSITY

144-364 gpi ± 5%

6 D.P. IN ANTHRACITE FIKTERS

0-2500 mm WC

± 1%

7 BRINE FLOW TO ANTHRACITE FILTERS

0-50 m3/hr ± 1%

8 ANTHRACITE FILTER BACKWASH FLOW

0-100 m3/hr ± 1%

9 RESIN TOWER BRINE FLOW

0-100m3/hr ± 1%

10 Na2CO3 TANK-A 0-4200 mm ± 1%

Page 45: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

LEVEL WC111 Na2CO3 TANK-B

LEVEL0-4200 mm WC

± 1%

12 FLOXIN TANK-A LEVEL

0-1800 mm WC

± 1%

13 FLOXIN TANK-B LEVEL

0-1800 mm WC

± 1%

14 CLARIFIED BRINE TANK LEVEL

0-4720 mm WC

± 1%

15 FILTERED BRINE TANK LEVEL

0-3900 mm WC

± 1%

16 BODY FEED TANK LEVEL

0-2900 mm WC

± 1%

17 PRE-COAT TANK LEVEL

0-2900 mm WC

± 1%

18 POLISHED BRINE TANK LEVEL

0-4700 mm WC

± 1%

19 SECONDARY BRINE TANK LEVEL

0-6250 mm WC

± 1%

20 FEED BRINE TANK LEVEL

0-3200 mm WC

± 1%

21 DECHLORINATED BRINE TANK LEVEL

0-3400 mm WC

± 1%

22 SODIUM SULFATE TANK-A,B LEVEL

0-2000 mm WC

± 1%

23 CLARIFY BRINE TEMP

0-80 DEG ± 2 DEG

24 POLISHED BR TEMP

0-100 DEG ± 2 DEG

25 VACUUM PUPM SUCTION TEMP

0-100 DEG ± 1%

26 CAUSTIC STORAGE TANK TEMP

0-100 DEG ± 1%

27 20% NAOH TANK LVL

0-2000 mm WC

± 1%

28 32%TANK FLOW 0-25 m3/hr ± 1%29 STEAM INLET

PRESSURE0-16 KSC ± 1%

Page 46: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 6

Pumps and Valves

The chlor-alkali plant employs the following types of pumps:

Centrifugal pump Reciprocating pump Metering pump

The 4 wetting parts; front casing, impeller, stuffing box,/back casing and sleeve usually differ in MOC according to the application of the pump. The rest of the parts are made of the same MOC for almost every application. The following materials of construction are used for pumping various materials:

Pure brine: Stainless steel

Pure brine + chlorine gas: titanium

Acids

o H2SO4: Alloy 20

o HCl: polypropylene, Ceramic, Fibre reinforced plasic

NaOH: 3% Nickel casting or just Nickel

Molten salt: alloy of Cobalt and Molybdenum

For any other non-corrosive medium at normal temperature: Cast iron, Mild steel, Stainless steel may be used.

Up to clarified brine tank, no valves or pumps are used, the flow of the substances is completely due to gravity. After clarified brine tank, the clarified brine is circulated using butterfly valve; having MOCs of either Teflon or MSRL. A level indicating valve is also used in the line from clarified brine tank. The backwater from clarified brine tank is pumped out by backwater pump, having the MOC as Ti. The filtered brine from the brine filters is pumped using filtered brine pump. More than 30 valves are used for polishing filters. Pneumatic control valves are used to control the flow of brine in this region. As16% slurry is pumped as slurry, for this purpose, ODS pumps are used (pneumatically controlled).

Page 47: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

For fusion plant, all the lines are Ni lines, and all the pumps used are centrifugal pumps, except for the sugar pumps, which is a reciprocatory pump. For the molten salt line, wetted parts of pumps are made up of an alloy of molybdenum and cobalt, as the circulatory medium s highly corrosive, and also because this MOC is highly suitable for high temperature. TPL uses VFD (variable frequency drive), which is a mode to save energy. Using this, they are able to run all motors at about 2100 rpm, which can be varied using VFD according to required flow rates.

Page 48: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 7

Motors RPM make types

Electric motors have a tremendous impact on overall energy use. Between 30 to 40 percent of all fossil fuels burned are used to generate electricity, and two-thirds of that electricity is converted by motors into mechanical energy. The two basic parts of an induction motor are the stationary stator located in the motor frame and the rotor that is free to rotate with the motor shaft. The basic simplicity of this design ensures high efficiency and makes them easily adaptable to a variety of shapes and enclosures. By varying the design of the basic squirrel-cage motor, almost any characteristic of speed, torque, and voltage can be controlled by the designer. The speed of an ac induction motor depends on the frequency of the supply voltage and the number of poles for which the motor is wound. The term pole refers to the manner in which the stator coils are connected to the three incoming power leads to create the desired rotating magnetic field. Motors are always wound with an even number of poles. The higher the input frequency, the faster the motor runs. The more poles a motor has, the slower it runs at a given input frequency. The synchronous speed of an ac induction motor is the speed at which the stator magnetic flux rotates around the stator core at the air gap. At 60 Hz the following synchronous speeds are obtained:

Table 9. RPM for No. of Poles

Number of poles RPM2 3,6004 1,8006 1,2008 90010 72012 600

Providing the motor is properly constructed, the output speed can be doubled for a given number of poles by running an ASD supplying the motor at an output frequency of 120 Hz. Induction motors are made with slip ranging from less than 5% up to 20%. A motor with a slip of 5% or less is known as a normal-slip motor. A normal-slip motor is sometimes referred to as a 'constant speed' motor because the speed changes very little from no-load to full-load conditions. A common four-pole motor with a synchronous speed of 1,800 rpm may have a no-load speed of 1,795 rpm and a full-load speed of 1,750 rpm. The rate-of-change of slip is approximately linear from 10% to 110% load, when all other factors such as temperature and voltage are held constant. Motors with slip over 5% are used for hard to start applications.

Page 49: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Historically a variety of terms have been used to describe a system that permits a mechanical load to be driven at user-selected speeds. These terms include, but are not limited to:

Variable-Speed DriveVariable-Frequency DriveAdjustable-Frequency DriveAdjustable-Speed Drive

The term variable implies a change that may or may not be under the control of the user. Adjustable is the preferred term since this refers to a change directly under control of the user. The term frequency can only be applied to drives with an ac output, while the term speed is preferred since this includes both ac and dc drives. Thus, the term most commonly accepted is Adjustable-Speed Drive (ASD).

Most ASD units consist of three basic parts. A rectifier that converts the fixed frequency ac input voltage to dc. An inverter that switches the rectified dc voltage to an adjustable frequency ac output voltage. (The inverter may also control output current flow, if desired.) The dc link connects the rectifier to the inverter. A set of controls directs the rectifier and inverter to produce the desired ac frequency and voltage to meet the needs of the ASD system at any moment in time.

The advantages of ASDs do not stop with saving energy and improving control. ASD technology can now be applied to manufacturing equipment previously considered too expensive or uneconomical. Such applications are often unique to a particular industry and its equipment, or even to a particular facility. Cost benefits, such as those obtained from improved quality, may be desirable for each application.

The motors at the Heavy Chemicals Division of TPL are powered by a pair of recently installed DG sets. These have greatly helped meet the power requirements of the chlor-alkali plant and have also ensured un-interrupted power supply to the fragile membrane cells which in turn avoided generation of effluents due to power shortages.

Page 50: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Chapter 8

Environmental Issues

I Impact Identification.

Introduction.

Environmental consequences which are generally known as impacts, is creation of a new set of Environmental conditions, adverse or beneficial inducted by the action or the set of actions under considerations. The impact analysis of different factors of the operation of the plant is shown below.

The impacts during operational phase:

1. Socio Economic Impacts.Replacement of the mercury cells by the membrane cells has helped abate the problem of effluent disposal, which no more contains mercury.The plant operation requires a total power of 4.5 lac units/day, which it gets from two sources, partially from Tamilnadu Electricity Board, and the rest from its owned DG sets. The installation of the DG sets helped meet the power requirement of the chlor-alkali plant and also ensured un-interrupted source of power supply to the fragile membrane cells which avoided the generation of effluents due to power shut-down.

And hence newer installations directly imply more number of job opportunities. This will help improve the status of the peripheral local communities whose living standards will go up considerably due to the higher income levels, better medical facilities and communication advances and access to better education facilities. Due to marginal increase in employment opportunities associated with the modernization, development is bound to occur. On the above scores, the impact will be marginally positive in this action.

2. Air Quality

a) Impact on air quality due to plant emission.Ambient air ambient air quality levels wit respect to SPM, SO2, NOx are well

within the prescribed limit by CPCB and MOEF in the core and buffer zone. The outlet compositions of the stacks existing within the premises of the plant are tabulated in table Note: As H2 is used as fuel in boiler there’ll be no SO2 emissions.

Page 51: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The emissions of SPM, SO2, NOx, acid mist and Cl2 from utilities as well as scrubbers are well within the limits. These stacks are monitored regularly enforce preventive measures in case of any excess.\

Table 10 Stack Data

No. Stack Attached To

Fuel Type

Stack Height

m

Stack Dia

m

Temperature

°C

Volume of gasNm3/hr

1. Caustic Fusion Plant

(Concentrator Stack)

H2 20 0.8 200 °C 3 MT/hr steam

2. Caustic Fusion Plant (Salt Heater)

H2 25 0.38 200 °C 2000

3. Steam Boiler H2 354. DG Cell Set Fuel Oil 8 0.15 200 °C 5005. WAD Plant 1 16 0.3 30 °C 11006. WAD Plant 2 16 0.3 15 °C 1100

The following control measures have been incorporated\ for controlling the emissions.1. Each HCl unit is filled with a tail gas scrubber for removing traces of HCl (acid

mist) present.2. Excess of NH3 from the NH4Cl plant is washed with DM water in mother liquor

scrubber packed with poly propylene packing to remove excess of NH33. Cl2 waste gases are removed by neutralization and absorption of caustic

soda/milk of lime towers.

Due to enforcement of various control measures, impact on air quality due to existing plant operations are well within sustainable limits.

a) Impact on air quality due to DG sets.Initially fuel oil was employed for the operation of DG sets which was later replaced by environmentally friendly fuels like LSHS, LSWR, and LNG etc. as liquid fuels are used. The impacts due to SPM are negligible. SO2 and NOx are major pollutants whose impacts are to be contained during the operational phase of the plant.

The impacts on air quality due to the following fuels are considered.(i) fuel oil with 4 % sulfur content(ii) LHS with 1.9 % sulfur content(iii) LNG with 0.001 % sulfur content

b) Impact on air quality due to heavy fuel oil.In the hot flue gases let out in the stack, SO2 and NOx are the major pollutants. The quantum of SO2 and NOx emission from the plant will be as below;

Page 52: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

SO2 emission(i) Total fuel (HFO) consumption = 3800 kg/hr(ii) S content (max) in HFO = 4.0%(iii) S load produced assuming 100% combustion = 4% of 3800 = 152 kg/hr(iv) Quantity of SO2 gas produced = 152*2 = 304 kg/hr = 84.4 kg/sec

Considering that 3 DG sets (2 running and 1 standby) will give an output of 30 MW the emission rate of SO2 from each stack is 42.2 g/sec

NOx emissionThe NOx emission from the stack will be restricted to 1100 ppm which will lead to emission rate of 61.6 g/sec

c) Impact on air quality due to LNG

LNG is the most environmentally friendly fuel with S content as low as 0.001 % which will lead to almost negligible SO2 emission. The NOx emission will also be 61.6 g/sec

Air Quality ModelingThe emission rates calculated above have been subjected to the PTDIS model to asses the impact on the air quality due to dispersion effects. Inputs to the model are given below:

Stack height : 65.5 mStack Diameter: 1.7 mStack temperature: 453 KExit Velocity : 12.22 m/secEmission rate For SO2 : 42.2 g/sec

PTDIS ModelIt is an interactive program that estimates the short term concentration directly down wind of a point source at a distance specified by the user. The effect of estimation vertical dispersion by mixing heat can be included. The model uses Briggs-Phume residency method and Pasquilli-Grifford Dispersion methods for this.The various inputs required to run this model are:

Number of sources Number of receptors Emission rate, physical stack height and diameter, stack gas temperature and stack

gas velocity for each value entered. Number of meteorological scenarios. For each scenario, the meteorological information required is wind velocity,

ambient temperature and mixing heights.

Page 53: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The PTDIS model was run for respective wind velocities (1.5 m/s, 2 m/s, 6.5 m/s and 8.0 m/s) and stability classes 2 and 4 taking into account the natural stability.

Analysis of dispersion model

The ground level concentrations have been worked out as mentioned earlier for each of the gas from the stack and predicted in a consolidated form for each parameter namely SO2, NOx in tables 2 for short term concentrations and corresponding 8 hourly and 24 hourly values. For SO2, the max short term concentration, 8 hourly and 24 hourly values due to the use of HFO are 339.0, 99.0, and 66.0 respectively at a downwind distance of 1 km where LSHS is used.The SO2 maximum 8 hourly and 24 hourly values will be 150.0, 45.0 and 30.0 at a distance of 1 km.For NOx the maximum short term concentration 8 hourly and 24 hourly values due to the stack are 351.0, 105.3, and 10.20 mg/m3 respectively at a downwind distance of 1.0 km for 3 stacks. In reality, GLC will be less due to changing wind direction, combined effects of alternating sources and other Environmental factors. Even after addition of projected ground level concentrations to the existing background loads when 2 GD sets are in operation the ambient air quality will be maintained within prescribed limits both in core and buffer zones.With introduction of LSHS and LNG as fuels, levels of SO2, NOx are relatively reduced.

Table 2 Level Concentration For SO2 (HFO as fuel) in mg/m3

No. Distance Short Term Concentration

(1 stack)

3 stacks 8 hourly 24 hourly

1. 0.50 34.00 102.00 30.60 1.212. 1.00 110 330.00 99 1.553. 2.00 48.40 145.2 43.56 2.24. 3.00 23.70 71.1 21.53 2.425. 4.00 13.90 41.7 12.51 2.726. 5.00 9.09 27.27 8.18 3.177. 6.00 6.61 19.83 5.95 3.978. 7.00 5.29 15.87 4.96 5.459. 8.00 4.53 13.59 4.08 8.3410. 9.00 4.04 12.12 3.64 14.2211. 10.00 3.67 11.01 3.3 29.0412. 15.00 2.58 7.74 2.32 66.0013. 20.00 2.02 6.06 1.82 20.40

3. Impact on water quality

Page 54: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

The entire water requirement of 1980 m3/day will be met from the metro water supply or from ground water sources located within the factory area. The auxiliary cooling water will be recycled and only make up water will be supplied. The domestic waste water generated which is about 80 m3/day will be treated with the existing sewage treatment plan. As such no waste water will be discharged from the process. Occasionally waste water containing oil and grease generated due to washing will also be treated in the ETP. Due to various Environmental control measures environmental aged the impact on water quality will be less.

Environmental Control Measures

General

The adverse affects of the various impacts due to the modernizations during the operational phase of the plant. These can be ameliorated and brought to sustainable limits by planning and adapting necessary measures.

1. Land UseThere was no agricultural land spoilage while setting up of the plant. As no forest land or hutments exist in the core zone, the question of rehabilitation and corresponding compensatory afforestation does not arise.

Socio Economic factorsThe plant is amidst an industrial area. Hence it enjoys all the conveniences of being close to other industries. The Manali industrial area is situated about 30 kms away from the metro Chennai. Consequently, the plant provides employment opportunities to people of many sections of society.

Air Quality.Ambient air quality is well within the limits of CPCB and MOEP. Also, LNG is being used as fuel instead of Heavy Fuel Oil, so less sulfur dioxide is released as pollutant gas.

Chlorine Neutralization of Vent Gases. (Wad Section)

Chlorine waste gases generated from chlorine storage and vent gases during start up are neutralized in two absorption towers where caustic lye is circulated. This system has additional caustic soda polishing column to ensure no chlorine escapes to the atmosphere. The vent gases being released into the atmosphere are been continuously monitored by an analyzer and being shown in the control room. Further, a sodium hypo system has also been introduced where chlorine is completely removed as sodium hypochloride by effective neutralization with caustic soda. The sodium hypochloride produced is saleable and does not contribute to any solid or liquid waste.

Capacity of Sodium Hypo System : 1 MT/hr Chlorine

Page 55: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Around 10 KL/day of sodium hypochloride solution is produced per day in this section and dispatched out as a by-product.

Water Quality

Water quality is maintained well within the prescribed limits as a result of treatment procedures described below:Waste water is treated using the principle of attraction while process waste water is disposed into the sea after pH neutralization. The total quantity of waste water from different sections is given below:

Process : 290 m3/dayDomestic : 80 m3/day

The treatment procedures for the two types of effluents are described below:

Method of Treatment of Sewage Effluent

Effluent waster from canteen contains oily matter and solid food particles that are bio degradable. The water is treated biologically for recovery and reuse in the canteen waste water treatment plant. Solids in the waste water are retained by a mesh screen and then sent to the oil removal pit, where the mater is relieved of its oil content. From the oil removal pit, the waste water flows from the collection tank by gravity. The water is then pumped to the equalization tank, which serves to smooth the variation in quality of effluent coming from the collection tank.A feed pump delivers waste water from equalization tank to the aeration tan, which is provided with two aerators. Reduction of Biological Oxygen Demand (BOD) takes place in the aeration tank, where microorganisms are allowed to grow for this purpose. From the aerator tank, water flows to the settling tank, where microbial sludge is separated. Clean water overflows to the treated water tank, from where it is pumped for reuse. Part of sludge is sent to sludge pits for disposal.

Effluent Treatment Process System

The process effluents come from the following sections:1. IEM plant floor washing - 20m3/day2. Brine section - 90 m3/day3. Boiler blowdown - 5 m3/day4. Caustic Soda Evaporation - 5 m3/day5. DM water plant - 100 m3/day6. Cooling water - 45 m3/day7. Hydrogen Unit - 15 m3/day8. Ammonium Chloride - 5 m3/day9. DG set (floor washing) - 5 m3/day

_______________

Page 56: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

290 m3/day _______________

The non-mercury bearing effluent stream is collected in the main effluent pit. 12 dia HDPE pipes laid underground connects effluents generated from different sections to collection pits/ main effluent pit.

Since cleaner technology is used, the effluents from the plant will not contain any hazardous chemicals. pH correction, if required, will be done and pumped to final disposal point along with the treated effluent from the canteen waste water treatment plant.

The combined treated effluents will continue to be pumped into the sea.

Water Quality Monitoring:

It is required to carry out continuous monitoring of treaded effluent quality in and around factory premisesThe quality of treated effluents in and around factory premises is being continuously monitored. The treated effluent quality is monitored at the outlet of individual in-plant effluent treatment as well as from the outlet after neutralization. Automatic sampler collectors are installed to collect samples continuously. From each point minimum eight hours composite samples will be collected and analyzed for the relevant pollutants as indicated in the respective treatment scheme. Regular sampling is conducted at the discharge point of the diffuser system to detect any deterioration of the treated effluent quality.

Environmental Management PlantIt is imperative to device in advance a proper management plant for Environmental control during operation phase of the plant so these measures can be enforced promptly. The HCD at TPL has a well lad out management plan and proper implementations of various control measures have helped to keep the Environmental quality within sustainable limits. The main environmental factors which are to be included have been given due consideration in the management plan are the following.

1. Ambient air quality for the monitoring of SPM, SO2 and NOx emissions to asses the efficiency of control measures incorporated.

2. Ecological factors3. Ambient noise in the plant area and the surrounding buffer zone.

a. Water analysis due to discharge of treated effluents.b. Safety and health measures.

Regular systematic and sustained program schedule for implementation and monitoring of various control measures are to be devised in advance with clear cut guidelines for various plants for keeping a continuous surveillance on the environmental quality of the

Page 57: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

area. It is noteworthy to highlight here that a full fledged control scheme to minimize the impacts on environmental factors has already been adapted.

Statutory Fulfillments

The monitoring schedules will be planned to aim at regular and systematic study of various pollution levels with respect to air and water qualities, noise levels, etc., to ensure that they conform to the standards laid down by the Central and State Pollution Control Board limits. Stack emissions are and shall be monitored regularly to check the efficacy of the control equipments.All the stipulations in respect of methodologies and studies of various parameters by MOEF and State Pollution Control Board should be followed.Wherever excess levels are noticed, prompt control measures will have to be effected to bring the quality parameters under control.Socio-economic status with respect to health, education occupational health, communication welfare measures etc are reviewed at least once in three years to bring them on par with the population growth, social development etc.HCD at TPL has adapted environmental control and management as a corporate policy to ensure that all the parameters for various environmental components such as air, water, noise, soil, etc conform strictly to standards of Central and State Pollution Control Board. The general manager will over see the environmental management system directly, duly supported by the concerned departmental executives.

Environmental Management Cell

This cell will oversee the measures to be taken under the Environmental Management Plan to ensure the impacts arising from the pollutional parameters of the power plant are within prescribed limits. For this purpose the cell will comprise of a monitoring group and a pollution control equipment maintenance group.The environmental management cell will oversee the following aspects.a) Conducting environmental audits and reporting to TNPCBb) Sending periodical monitoring reports as prescribed by TNPCB and other statutory

authorities.c) Recommending in advance necessary measures to improve the environmental aspects.d) Conducting safety audits and programs and safety awareness among workers/staff.e) Conduct annual health audits to detect any health problems promptly in the

workers/staff.

Ambient Air Quality and Stack Monitoring.For ambient air quality monitoring, necessary instruments such as high volume

samples are available. Stack monitoring is conducted regularly in the existing unit available stack monitoring kits, SO2 Analyzer, Automatic Recording emitter, Weather data etc. these will be adapted by respective instruments having high accuracy.

Water Quality Monitoring

Page 58: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

It is required to carry out monitoring of treated effluent quality in and around factory premises. The treated effluent quality should be monitored at the outlet of individual in-plant effluent treatment units as well as from the outlet after neutralization. Automatic sample collectors are installed to collect the samples continuously from each point. Minimum 8 hours of composite samples shall be collected and analyzed for relevant pollutants as indicated in the respective treatment schemes described. The effluent samples are collected and analyzed daily. Regular sampling is conducted at the discharge point of the diffuser system to detect any deterioration of the treated effluent quality. The marine ecosystem will also be continuously monitored.

Soil Quality Monitoring.Monitoring program for the soil will help in the improvement in physical and

chemical properties of the soil corresponding improvement in ground water quality and water table levels. Thus, monitoring measures may provide useful guidelines and for taking remedial measures in time for the result and any further development in the activities in the area.

Environmental Control CostTowards pollution control, a capital investment of Rs. 287 lacs has been made of

which Rs. 207 lacs has been spent for pollution control schemes to control water pollution. During the modernization program, Rs. 40 lacs were spent towards air pollution control equipment and Rs. 30 lacs was spent on Green Belt Development.Besides, the annual expenditure for operation and management is about Rs. 69 lacs for air pollution and Rs. 10 lacs for ETP.

Page 59: Industrial Manufacturing of Caustic Soda Flakes at Tamilnadu Petroproducts Ltd

Summary

The heavy chemicals division of tamilnadu petroproducts limited produces about 100 MT/day of Caustic Soda Flakes (98%), along with hydrogen and chlorine as by-products. the mere raw materials it uses are water, electricity and raw salt. The plant is powered by a set of 3 Deisel generator Sets, 2 always operational and one on standby. The plant makes the use of Membrane Cell technology in the electrolyzers, which relatively more eco-friendly, cheap and efficient in terms of quality of the product. Despite of a few power cuts due to heavy rains, it was observed during the training period that the plant was operating at par with the demand of caustic soda flakes. It makes good use of the gases it generates as by-products in generating power or other chemical substances. TPL takes complete care of all the safety norms required to be followed to ensure the safety of its employees, workers and the surrounding environment. The training was a healthy learning experience.