infrared spectroscopy

28
INFRARED SPECTROSCOPY Pramod K Singh School of Basic Sciences &Research Sharda University, Greater Noida, INDIA

Upload: rendor

Post on 22-Jan-2016

61 views

Category:

Documents


4 download

DESCRIPTION

INFRARED SPECTROSCOPY. Pramod K Singh School of Basic Sciences &Research Sharda University, Greater Noida, INDIA. What is Infrared ?. IR radiation lies betn the visible and microwave portions of the em spectrum. *Infrared waves have wavelengths longer than visible and shorter - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: INFRARED SPECTROSCOPY

INFRARED SPECTROSCOPY

Pramod K SinghSchool of Basic Sciences &Research

Sharda University, Greater Noida, INDIA

Page 2: INFRARED SPECTROSCOPY

What is Infrared?IR radiation lies betn the visible and microwave portions of the em spectrum.

*Infrared waves have wavelengths longer than visible and shorter

than microwaves, and have frequencies which are lower than visible and higher than microwaves.

• The IR region is divided into: near, mid and far-infrared.

– Near-infrared refers to the part of the infrared spectrum that is closest to visible light

– far-infrared refers to the part that is closer to the microwave region.

– Mid-infrared is the region between these two.

Page 3: INFRARED SPECTROSCOPY

What is Infrared?• The primary source of infrared radiation is thermal radiation. (heat)

• It is the radiation produced by the motion of atoms and molecules in an object.

• The higher the temperature, the more the atoms and molecules move and the more infrared radiation they produce.

• Any object radiates in the infrared. Even an ice cube, emits infrared.

Page 4: INFRARED SPECTROSCOPY

*The IR region of the em spectrum covers a wide range of wavelengths, from about 800 nm (end of the visible region) to about 0.2 mm (beginning of the microwave region).

*The units of wavelength commonly employed in the infrared region is wave number, = 1/, in reciprocal cm (cm-1).

Page 5: INFRARED SPECTROSCOPY

Infrared radiations• IR does not have sufficient energy to cause the

excitation of e, however it causes atoms and group of atoms of organic compounds to vibrate faster about the covalent bonds which connect them.

• The vibrations are quantised as they occur, the compound absorbs infrared energy in particular regions of the spectrum.

Page 6: INFRARED SPECTROSCOPY
Page 7: INFRARED SPECTROSCOPY

What is a vibration in a molecule?

Any change in shape of the molecule- stretching of bonds, bending of bonds, or internal rotation around single bonds

Page 8: INFRARED SPECTROSCOPY

Molecular VibrationsCovalent bonds vibrate at only certain

allowable frequencies.

Page 9: INFRARED SPECTROSCOPY

Calculation of vibrational frequencies :Let us consider a chemical bond to be a stretched spring. Then according to the Hooke’s law the frequency of vibration depends upon the strength of the bond.

Stronger the bond more is the amount of energy required to stretch it.

Wave numbers are proportional to energy. K is force constant

Page 10: INFRARED SPECTROSCOPY

Conditions for I R activity (Selection Rule)The necessary conditions for a molecule to be IR active are:

*The frequency of IR radiation must be equal to the vibrating frequency of a particular group or bond in the molecule

*The molecule must have finite dipole moment.

* If it does not have dipole moment,Some of its vibrations must produce an induced dipole moment.

Page 11: INFRARED SPECTROSCOPY

Asymmetrical stretching/bending and internal rotation change the dipole moment of a molecule. Asymmetrical stretching/bending are IR active.

Symmetrical stretching/bending does not and hence Not IR active

Page 12: INFRARED SPECTROSCOPY

IR-Active and Inactive

• A polar bond is usually IR-active.

• A nonpolar bond in a symmetrical molecule will absorb weakly or not at all.

Page 13: INFRARED SPECTROSCOPY

Infrared spectrometerdouble – beam infrared spectrometer. Its essential features are described briefly as follows:

Page 14: INFRARED SPECTROSCOPY

(i) Radiation source : *Small ceramic rod, heated electrically in the range 1100 – 18000C and is made

of either silicon carbide (Glowbar) or Nernst filament (a high – resistance, brittle element composed of mixture of sintered oxides of zirconium, thorium and cerium held together by a binding material).

The radiation is divided into two beams, one of which passes through the sample while the other function as a reference beam. The reference and the sample beams are then passed alternately into a monochromator at very short intervals by means of a rotating mirror.

Page 15: INFRARED SPECTROSCOPY

(ii) Absorption cells and sample preparation : The cells generally employed are made up of rock salt or potassium bromide

*(glass and quartz cells are unsuitable as these materials themselves absorb IR radiation).

Page 16: INFRARED SPECTROSCOPY

(iii) Monochromator : The pulse beam enters the monochromator through an entrance slit and is dispersed by a grating or by a Littrowmount prism.

In the monochromator the emergent beams are sorted out into individual wave lengths by means of sodium chloride prism which is transparent to infrared radiation throughout the range 4000 – 550 cm-1.

Page 17: INFRARED SPECTROSCOPY

(iv) Detector, Amplifier and Recorder : The pulsating single beam now emerging through the exit slit is a narrow band consisting of only a very few frequencies

After this sorting out (dispersion), the beams are focused alternately at each particular wave length throughout the spectral range, by means of a mirror system on to the detector, usually a sensitive fast thermocouple.

Page 18: INFRARED SPECTROSCOPY

The signals from this are amplified electronically and by means of a mechanical arrangement, the spectrum is recorded on a special graph paper mounted on a rotating drum.

Page 19: INFRARED SPECTROSCOPY

FT-IR Spectrometer• Fourier transform infrared spectroscopy is a technique for

obtaining high quality infrared spectra by mathematical conversion of an interference pattern into a spectrum.

• Uses an interferometer.• Has better sensitivity.• Less energy is needed from source.• Completes a scan in 1-2 seconds.• Takes several scans and averages them.• Has a laser beam that keeps the instrument accurately

calibrated.

Page 20: INFRARED SPECTROSCOPY

FTIR seminar

Interferometer

He-Ne gas laser

Fixed mirror

Movable mirror

Sample chamber

Light source

(ceramic)

Detector

(DLATGS)

Beam splitter

FT Optical System Diagram

Page 21: INFRARED SPECTROSCOPY

How the IR spectra of solid, liquid and gaseous compounds recorded?

1. The spectrum of a solid sample is determined with an alkali halide pellet. About 1-3 mg of substance and 100-200 mg of alkali halide are ground together, dried to remove moisture and pressed at room temperature under high pressure into a small disc. KBr does not absorb IR radiation in the region 4000-650 cm-1 a complete spectrum of the solid is obtained. 2. For free flowing liquids a neat spectrum may be recorded. 3. Spectrum of a substance in a solution can also be done by using cells of 0.1 mm with 10% solution are used. CCl4, CS2

and CHCl3 are the solvents to be used. 4. The spectra of gases or low boiling liquids can be obtained by expansion of the sample into an evacuated cell.

Page 22: INFRARED SPECTROSCOPY

An Alcohol IR Spectrum

Page 23: INFRARED SPECTROSCOPY

An Amine IR Spectrum

Page 24: INFRARED SPECTROSCOPY

Carbonyl Stretching

• The C=O bond of simple ketones, aldehydes, and carboxylic acids absorb around 1710 cm-1.

• Usually, it’s the strongest IR signal.

• Carboxylic acids will have O-H also.

• Aldehydes have two C-H signals around 2700 and 2800 cm-1.

Page 25: INFRARED SPECTROSCOPY

A Ketone IR Spectrum

Page 26: INFRARED SPECTROSCOPY

An Aldehyde IR Spectrum

Page 27: INFRARED SPECTROSCOPY

O-H Stretch of a Carboxylic Acid

This O-H absorbs broadly, 2500-3500 cm-1, due to strong hydrogen bonding.

Page 28: INFRARED SPECTROSCOPY

Thank you