inglewood unified school district - …measuregg.myiusd.net/wp-content/uploads/2016/11/iusd...kd...
TRANSCRIPT
INT INTERIORINV INVERT
J-BOX JUNCTION BOXJAN JANITORJST JOISTJT JOINT
KD KNOCK DOWNKIT KITCHENKO KNOCK OUT
LAB LABORATORYLAM LAMINATELAV LAVATORYLDG LANDINGLKR LOCKERLOS LINE OF SIGHTLT LIGHT
MACH MACHINEMAX MAXIMUMMECH MECHANICALMEMB MEMBRANEMEZZ MEZZANINEMFG MANUFACTURINGMFR MANUFACTURERMH MANHOLEMIN MINIMUMMIR. MIRRORMISC MISCELLANEOUSML METAL LATHEMO MASONRY OPENINGMTD MOUNTEDMTL METALMULL MULLION
(N) NEWNA NOT APPLICABLENC NURSE CALLNCA NURSE CALL ANNUNCIATORNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNR NO RATINGNTS NOT TO SCALE
OA OVERALLOC ON CENTEROD OUTSIDE DIAMETEROF/CI OWNER FURNISHED,
CONTRACTOR INSTALLEDOF/OI OWNER FURNISHED, OWNER
INSTALLEDOFF OFFICEOH OPPOSITE HANDOP OVERFLOW PIPEOPNG OPENINGOPP OPPOSITEOPT OPTIONALORIG. ORIGINAL
LB POUNDSPART PARTITIIONPERM PERIMETERPERP PERPENDICULARPG PAINT GRADEPIP PROTECT IN PLACEPL PLATEPLAM PLASTIC LAMINATEPLAS PLASTERPLAS PLASTICPLYWD PLYWOODPR PAIRPRCST PRECASTPT PAINTPTD PAINTEDPTN PARTITION
R RISERRAD RADIUSRCP REFLECTED CEILING PLANRD ROOF DRAINRE REFERREF REFERENCEREF REFRIGERATORREINF REINFORCEDREQD REQUIREDRESIL RESILIENTRM ROOMRO ROUGH OPENINGRT RIGHTRTU ROOF TOP UNIT (MECH)RUB RUBBER
# NUMBER, POUND@ ATAB ANCHOR BOLTABV ABOVEACOUS ACOUSTICALACT ACOUSTICAL CEILING TILEAD AREA DRAINADJ ADJUSTABLEAFF ABOVE FINISH FLOORAGGR AGGREGATEALT ALTERNATEALUM ALUMINUMAPPROX APPROXIMATEARCH ARCHITECTASPH ASPHALT
BALC BALCONYBD BOARDBETW BETWEENBITUM BITUMINOUSBLDG BUILDINGBLKG BLOCKINGBLKHD BULKHEADBLW BELOWBM BEAMBOT BOTTOMBRKT BRACKETBU BUILT UPBULKHD BULKHEADBUR BUILD UP ROOF
CAB CABINETCALK CAULKINGCB CATCH BASINCEM CEMENTCER CERAMICCG CORNER GUARDCI CAST IRONCJ CONTROL JOINTCL CENTER LINECLG CEILINGCLOS CLOSETCLR CLEARCMU CONCRETE MASONRY UNITCO CASED OPENINGCOL COLUMNCONC CONCRETECONN CONNECTIONCONST CONSTRUCTIONCONT CONTINUOUSCORR CORRIDORCP CONTROL PANELCPT CARPETCT CERAMIC TILECTR CENTERCTSK COUNTERSINK
DBL DOUBLEDEMO DEMOLITIONDEPT DEPARTMENTDET DETAILDF DRINKING FOUNTAINDF WLMTD
DRINKING FOUNTAIN, WALLMOUNTED
DIA DIAMETERDIAG DIAGONALDIFF DIFFUSERDIM DIMENSIONDISP DISPENSERDN DOWNDOCS. DOCUMENTSDR DOORDS DOWNSPOUTDWG DRAWING
(E) EXISTINGEA EACHEIFS EXTERIOR INSULATION &
FINISH SYSTEMEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRIC(AL)ELEV ELEVATOREMER EMERGENCYENCL ENCLOSUREENG ENGINEERINGEOS EDGE OF SLABEQ EQUALEQUIP EQUIPMENTETR EXISTING TO REMAINEW EACH WAYEWC ELECTRIC WATER COOLEREWH ELECTRIC WATER HEATEREXIST EXISTINGEXP EXPOSEDEXPAN EXPANSIONEXT EXTERIOR
REFERENCE GRID INDICATOR -EXISTING
REFERENCE GRID INDICATOR - NEW
DETAIL ENLARGEMENT
BUILDING SECTION
DESCRIPTIONSYMBOL
MATCHLINEN
NORTH ARROW
LEVEL 1100'-0"
VERTICAL ELEVATION DATUMRELATIVE TO FIRST LEVEL
(E) LEVEL 1100'-0"
VERTICAL ELEVATION DATUM(EXISTING)RELATIVE TO FIRST LEVEL
ROOM TAGROOM NAME101
ROOM NAME101
100 S.F.
WALL TAG1S4Ab
DOOR TAG101
1 WINDOW TAG
A101
1
1 1
1
EXTERIOR ELEVATION
A101
1
1 1
1
INTERIOR ELEVATION
1
A101
SIMDETAIL INDICATOR
WALL SECTION
1i FURNITURE, CASEWORK,EQUIPMENT TAG,SPECIALTYEQUIPMENT
FINISH 1 FINISH 2 FLOOR FINISH TRANSITION
101
BA
2
1
SYMBOLS LEGEND
INTERIOR FINISHSCHEDULE
DRAWING TITLE
SAFB SOUND ATTENUATION FIBERBATT
SC SCUPPERSC SOLID CORESCHED SCHEDULESEAL SEALANTSECT SECTIONSFSHR SHOWERSHT SHEETSIM SIMILARSPEC SPECIFICATIONSQ SQUARESS STAINLESS STEELSTD STANDARDSTL STEELSTOR STORAGESTRUCT STRUCTURALSUSP SUSPENDEDSYM SYMETRICAL
T TREADT&G TONGUE & GROOVETEL TELEPHONETER TERRAZZOTHK THICKTHR THRESHOLDTO TOP OFTOC TOP OF CURBTOM TOP OF MASONRYTOP TOP OF PARAPETTOR TOP OF ROOFTOS TOP OF SLABTYP TYPICAL
UC UNDERCUTUNFIN UNFINISHEDUNO UNLESS NOTED OTHERWISEUON UNLESS OTHERWISE NOTEDUTIL UTILITY
VCT VINYL COMPOSITION TILEVERT VERTICALVIF VERIFY IN FIELDVTR VENT TERMINATION PIPVWC VINYL WALL COVERING
W/ WITHW/O WITHOUTWC WATER CLOSETWD WOODWIN WINDOWWP WATERPROOFWP WORKING POINTWS WETSTACKWSCT WAINSCOTWT WEIGHT
CON
TACT
INFO
RMAT
ION
:
INGLEWOOD UNIFIED SCHOOL DISTRICTRESTROOM INTERIOR UPGRADE- PHASE 1
PROJECT DATA
1. SCHOOL NAME: PAYNE ELEMENTARY SCHOOLADDRESS: 215 W 94TH ST, INGLEWOOD, CA 90301PHONE: (310) 680-5410
2. SCHOOL NAME: INGLEWOOD HIGH SCHOOLADDRESS: 231 S GREVILLEA AVE, INGLEWOOD, CA 90301PHONE: (310) 680-5200
3. SCHOOL NAME: WILLIAM H. KELSO ELEMENTARY SCHOOLADDRESS: 809 E KELSO ST, INGLEWOOD, CA 90301PHONE: (310) 680-5480
4. SCHOOL NAME: OAK STREET ELEMENTARY SCHOOLADDRESS: 633 S OAK ST, INGLEWOOD, CA 90301PHONE: (310) 680-5340
5. SCHOOL NAME: CLAUDE HUDNALL ELEMENTARY SCHOOLADDRESS: 331 W OLIVE ST, INGLEWOOD, CA 90301
PHONE (310) 680-5420
6. SCHOOL NAME: HILLCREST HIGH SCHOOLADDRESS: 441 W HILLCREST BLVD. INGLEWOOD, CA 90301
PHONE: (310) 680-5300
BID SET - 11/04/2016
DRAWING SHEET INDEXSHT # SHEET NAME
ARCHITECTgkkworks155 S Fair Oaks Pasadena, CA 91105P:(626) 666-6906 F:(626) 988-1085CONTACT : Javan [email protected] : Albert Quesada/ [email protected]
OWNERInglewood Unified SchoolDistrict401 S. Inglewood Ave.Inglewood, CA 90301P:(310) 680-4812CONTACT : Mark Ferguson/ Dir. of [email protected]
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
G001
TITLE SHEETCONTACT INFORMATIONDRAWING SHEET INDEX
-
-
- -
1. 2013 CALIFORNIA ADMINISTRATIVE CODE (CAC)PART 1, TITLE 25, CALIFORNIA CODE OF REGULATIONS (CCR)
2. 2013 CALIFORNIA BUILDING CODE (CBC)PART 2, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) (BASED ON THE 2012INTERNATIONAL BUILDING CODE (IBC) AND 2013 CALIFORNIA AMENDMENTS)
3. 2013 CALIFORNIA ELECTRICAL CODE (CEC)PART 3, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) (BASED ON THE 2011NATIONAL ELECTICAL CODE (NEC) AND 2010 CALIFORNIA AMENDMENTS)
4. 2013 CALIFORNIA MECHANICAL CODE (CMC)PART 4, TITLE 24, CALIFORNIA CODE OF REGUILATIONS (CCR) (BASED ON THE 2012UNIFORM MECHANICAL CODE (UMC) AND 2010 CALIFORNIA AMENDMENTS)
5. 2013 CALIFORNIA PLUMBING CODE (CPC)PART 5, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) (BASED ON THE 2012UNIFORM PLUMBING CODE (UPC) AND 2010 CALIFORNIA AMENDMENTS)
6. 2010 CALIFORNIA ENERGY CODE (PART 6, TITLE 24, CCR)(2011 CALIFORNIA ENERGY COMMISSION BUILDING ENERGY EFFICIENCY STANDARDS)
7. 2013 CALIFORNIA FIRE CODE (CFC)PART 9, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) (BASED ON THE 2012INTERNATIONAL FIRE CODE (IFC) AND 2010 CALIFORNIA AMENDMENTS)
8. 2013 CALIFORNIA EXISTING BUILDING CODE (CEBC)PART 10, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR) (BASED ON THE 2009INTERNATIONAL EXISTING BUILDING CODE (IEBC) AND 2010 CALIFORNIA AMENDMENTS)
9. 2013 CALIFORNIA REFERENCED STANDARDS CODE (CRSC)PART 12, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
10. 2013 CALGREEN CODE
11. NFPA 13 - 2013 STANDADRD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
12. NFPA 72 - 2013 NATIONAL FIRE ALARM AND SIGNALING CODE
13. N.F.P.A. - 101 LIFE SAFETY CODE
14. O.S.H.A.- OCCUPATIONAL SAFETY AND HEALTH ACT
APPLICABLE CODES
G001 TITLE SHEET / CONTACT INFORMATION / DRAWING SHEET INDEXA103 PAYNE ELEMENTARY SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA107 INGLEWOOD HIGH SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA108 KELSO ELEMENTARY SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA110 OAK STREET ELEMENTARY SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA111 HUNDALL ELEMENTARY SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA117 HILLCREST HIGH SCHOOL DEMO & REMODEL RESTROOM FLOOR, CEILING
PLANS & ELEVATIONSA201 MOUNTING HEIGHT AND DETAILS
ABBREVIATIONS
BOYSE-3
4
GIRLSF-6
3
30"x48"30"x48"
30"x48"
BCD A
BCD A
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
21/4" = 1'-0"
BOYS & GIRLS RESTROOM REMODEL PLAN
11/4" = 1'-0"
BOYS & GIRLS RESTROOM DEMO PLAN
31/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONS
41/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
61/4" = 1'-0"
BOYS & GIRLS RESTROOM RCP PLAN
RESTROOM INTERIOR
UPGRADE
5N.T.S.
SITE PLAN
AREA OF WORK
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
1---
2---
6---
DEMO (E) CERAMIC TILE FLOORING & MORTAR SET
DEMO (E) TOILET FIXTURE
DEMO (E) LAVATORY
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE ALL TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) TILE WAINSCOT & MORTAR SET TO FRAMING.
DEMO (E) URINAL
REPLACE GLAZING WITH NEW FROSTED TYPE.
DEMO (E) WALL FINISH TO FRAMING.
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
CLEAN (E) MECHANICAL DIFFUSER/REGISTERS
NOT USED
NOT USED
(E) DOOR & HARDWARE TO REMAIN - PAINT DOOR
(E) WINDOW & FRAME TO REMAIN. REFURBISH OPERATINGHARDWARE SO WINDOW OPENS/ LOCKS PROPERLY.
(E) FLOOR DRAIN TO REMAIN. CLEAR DRAIN LINE (100 LF).
NOT USED
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT EXISTING LOCATION.
REMOUNT AV STROBE DEVICE AT EXISTING LOCATION.TEST DEVICE FOR PROPER FUNCTION.
PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL CERAMIC TILE FLOORING & SETTING BED
INSTALL CERAMIC TILE WAINSCOT & SETTING BED.SEE A201/ DETS. 17 & 18.
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROWBODY, MODEL # AW-2- 32-AR-MVOLT-GEB10IS
NEW W.P. GYP.WALLBOARD FINISH. PAINT WALL
NOT USED
PAINT CEILING.
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
9
19
20
21
28
10
29
SCOPE OF WORK
A103
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
PAYNE ELEMENTARY SCHOOL
7EXISTING SITE PHOTO
30INSTALL NEW LED LIGHT FIXTURE. EXTEND CIRCUIT TONEW FIXTURE LITHONIA NARROW BODY,MODEL # AW-2- 32-AR-MVOLT-GEB10IS
31 INSTALL NEW THRESHOLD SADDLE - SEE DET. 4/A201
1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
30"x48"
GIRLSF-6
4
MANCHESTER BOULEVARD
SO
UTH
GR
EV
ILLE
A A
VE
NU
E
A B C DA.1
A B C D
30"x48"
3
BOYSE-3
30"x48"
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
11/4" = 1'-0"
BOYS RESTROOM REMODEL PLAN71/4" = 1'-0"
BOYS RESTROOM DEMO PLAN
31/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
41/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONS
N.T.S.SITE PLAN
8EXISTING SITE PHOTO
51/4" = 1'-0"
91/4" = 1'-0"
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
INGLEWOOD HIGH SCHOOL
RESTROOM INTERIOR
UPGRADE
21/4" = 1'-0"
BOYS RESTROOM RCP PLAN61/4" = 1'-0"
AREA OF WORK
DEMO (E) CERAMIC TILE FLOORING & MORTAR SET
DEMO (E) TOILET FIXTURE
DEMO (E) BUILT-IN SINK UNIT.
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE ALL TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) TILE WAINSCOT & MORTAR SET TO FRAMING.
DEMO (E) URINAL
DEMO PORTION OF (E) NON-BEARING PLUMBINGCHASE WALL FOR NEW WORK
DEMO (E) WALL FINISH TO FRAMING
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
CLEAN (E) MECHANICAL DIFFUSER/REGISTERS
REPLACE WINDOW GLAZING WITH NEW FROSTED TYPE.
DEMO (E) ROOF VENTILATOR. PROVIDE NEW VENTILATOR,GREENHECK MODEL GRS-15. PATCH ROOF.
(E) DOOR & HARDWARE TO BE REMOVED. (E) FRAME &SIDE PANELS TO REMAIN. PAINT.
(E) WINDOW & FRAME TO REMAIN. REFURBISH OPERATINGHARDWARE SO WINDOW OPENS/ LOCKS PROPERLY.
(E) FLOOR DRAIN TO REMAIN. CLEAR DRAIN LINE (100 LF).
(E) PLUMBING CHASE WALL TO REMAIN
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT EXISTING LOCATION.
REMOUNT AV STROBE DEVICE AT EXISTING LOCATION.PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL CERAMIC TILE FLOORING & SETTING BED
INSTALL CERAMIC TILE WAINSCOT & SETTING BED. SEEDETL. 17/ A201
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROW BODY, MODEL # AW-2- 32-AR-MVOLT-GEB10IS
NEW W.P. GYP.WALLBOARD FINISH - PAINT WALL
PAINT EXISTING POLE
PAINT EXISTING CEILING.
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
INSTALL NEW H.M. DOOR & HARDWARE - PAINT FRAME& SIDE PANEL
INSTALL NEW SS THRESHOLD SADDLE-SEE DETAIL 4/A201
9
19
20
21
28
10
29
SCOPE OF WORK
A107
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
INGLEWOOD HIGH SCHOOL
30
31
BOYS
GIRLS
INTERIOR UPGRADE OF EXISTING RESTROOMS INCLUDES:
1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
N.T.S.DOOR HARDWARE
30"x48"
BOYSE-3
3
30"x48"
30"x
48"
4
GIRLSF-6
A B C D
A B C D
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
11/4" = 1'-0"
BOYS RESTROOM REMODEL PLAN63/16" = 1'-0"
BOYS RESTROOM DEMO PLAN
31/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
41/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONS
N.T.S.SITE PLAN
2EXISTING SITE PHOTO
51/4" = 1'-0"
83/16" = 1'-0"
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
KELSO ELEMENTARY
SCHOOL RESTROOM
INTERIOR UPGRADE
73/16" = 1'-0"
BOYS RESTROOM RCP PLAN
AREA OF WORK
93/16" = 1'-0"
GIRLS RESTROOM RCP PLAN
DEMO (E) CERAMIC TILE FLOORING & MORTAR SET
DEMO (E) TOILET FIXTURE.
DEMO (E) LAVATORY.
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE (E) TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) TILE WAINSCOT & MORTAR SET TO FRAMING.
DEMO (E) URINAL.
EXISTING PARTIAL HEIGHT WALL TO REMAIN.
DEMO (E) WALL FINISH TO FRAMING
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
DEMO (E) CEILING COMPLETE FOR NEW WORK.
NOT USED.DEMO (E) EXHAUST FAN. INSTALL NEW FAN & GRILLE.MATCH SIZE AND POWER REQUIREMENT.
(E) DOOR & HARDWARE TO REMAIN. PAINT DOOR.
(E) WINDOW, GLAZING & FRAME TO REMAIN. REPLACEGLAZING PANEL WITH NEW FROSTED TYPE.(E) FLOOR DRAIN TO REMAIN. CLEAR DRAIN LINE (100 LF).
(E) PLUMBING CHASE WALL TO REMAIN
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT EXISTING LOCATION.
NOT USED.
PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL CERAMIC TILE FLOORING & SETTING BED
INSTALL CERAMIC TILE WAINSCOT & SETTING BED. SEESHEET A201/ DETS. 17 & 18.
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROW BODY, MODEL # AW-2- 32-AR-MVOLT-GEB10IS
INSTALL NEW W.P. GYP. BD. FINISH - PAINT WALL
PAINT EXISTING POLE.
INSTALL NEW W.P. GYP BOARD CEILING; PAINT.
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
NOT USED
INSTALL NEW S.S. THRESHOLD SADDLE-SEE DET. 4/A201
9
19
20
21
28
10
29
SCOPE OF WORK
A108
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
KELSO ELEMENTARY SCHOOL
INTERIOR UPGRADE OF EXISTING RESTROOMS INCLUDES:1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
30
31
BOYS
GIRLS
30"x48"
7
BOYS
30"x
48"
8
GIRLS
A B C D
GIRLS
BOYS
W SPRUCE AVENUE
S OA
K ST
REET
BOYS
GIRLS
A B C D
A110
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
11/4" = 1'-0"
BOYS RESTROOM REMODEL PLAN51/4" = 1'-0"
BOYS RESTROOM DEMO PLAN
21/4" = 1'-0"
GIRLS RESTROOM REMODEL PLAN61/4" = 1'-0"
GIRLS RESTROOM DEMO PLAN
71/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
81/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONS
3N.T.S.
SITE PLAN
91/4" = 1'-0"
BOYS RESTROOM RCP PLAN
101/4" = 1'-0"
GIRLS RESTROOM RCP PLAN
RESTROOM
INTERIOR UPGRADE
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
DEMO (E) CERAMIC TILE FLOORING & MORTAR SET
DEMO (E) TOILET FIXTURE
DEMO (E) LAVATORY
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE ALL TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) TILE WAINSCOT & MORTAR SET TO FRAMING.
DEMO (E) URINAL
REPLACE WINDOW GLAZING w/ NEW FROSTED TYPE.
DEMO (E) WALL FINISH TO FRAMING
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
NOT USED.
NOT USED.
INSTALL NEW WALL MOUNT FAN & GRILLE, GREENHECKMODEL CW-060, PROVIDE COMPLETE SYSTEM & (N) POWER.
(E) DOOR & HARDWARE TO REMAIN - PAINT DOOR
(E) WINDOW & FRAME TO REMAIN. REFURBISH OPERATINGHARDWARE SO WINDOW OPENS/ LOCKS PROPERLY.(E) FLOOR DRAIN TO REMAIN. CLEAR DRAIN LINE (100 LF).
(E) PLUMBING CHASE WALL TO REMAIN
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT EXISTING LOCATION.
REMOUNT AV STROBE DEVICE AT EXISTING LOCATION.TEST DEVICE FOR PROPER FUNCTION.
PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL CERAMIC TILE FLOORING & SETTING BED
INSTALL CERAMIC TILE WALL FINISH & CEMENT MORTAR.SEE A201/ DETS. 17 & 18.
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROW BODY, MODEL # AW-2- 32-AR-MVOLT-GEB10IS
NEW W.P. GYP. WALLBOARD FINISH- PAINT WALL
INSTALL NEW ACCESS PANEL- MATCH EXISTING SIZE.
PATCH EXISTING CEILING & PAINT.
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
INSTALL NEW SS TRESHOLD SADDLE-SEE DETAIL 4/A201
9
19
20
21
28
10
29
SCOPE OF WORK
11EXISTING SITE PHOTO
AREA OF WORK
30
BOYS
GIRLS
1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
30"x48"
4
3
BOYS
GIRLS
30"x
48"
30"x48"
30"x
48"
BOYS
GIRLS
MANCHESTER BLVD
OLIVE STREET
DCBA
BOYS GIRLS
A B DC
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
31/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONS
41/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
N.T.S.SITE PLAN
61/4" = 1'-0"
GIRLS RESTROOM RCP PLAN
HUDNALL ELEMENTARY
SCHOOL RESTROOM
INTERIOR UPGRADE
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
SCOPE OF WORK
A111
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
HUDNALL ELEMENTARY SCHOOL
AREA OF WORK
2EXISTING SITE PHOTO
11/4" = 1'-0"
BOYS & GIRLS RESTROOM REMODEL PLAN51/4" = 1'-0"
BOYS & GIRLS RESTROOM DEMO PLAN
DEMO (E) CERAMIC TILE FLOORING & MORTAR SET
DEMO (E) TOILET FIXTURE
DEMO (E) LAVATORY
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE ALL TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) TILE WAINSCOT & MORTAR SET TO FRAMING.
DEMO (E) URINAL
NOT USED
DEMO (E) WALL FINISH TO FRAMING
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
CLEAN (E) MECHANICAL DIFFUSER/REGISTERS
DEMO (E) ACCESS PANEL
DEMO (E) EXHAUST FAN. INSTALL NEW FAN & GRILLE
(E) DOOR & HARDWARE TO REMAIN - PAINT DOOR
NOT USED
(E) FLOOR DRAIN TO REMAIN. CLEAR DRAIN LINE (100 LF).
(E) PLUMBING CHASE WALL TO REMAIN
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT EXISTING LOCATION.
REMOUNT AV STROBE DEVICE AT EXISTING LOCATION.TEST DEVICE FOR PROPER FUNCTION.
PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL CERAMIC TILE FLOORING & SETTING BED
INSTALL CERAMIC TILE WALL FINISH & CEM. MORTAR BEDSEE A201/ DETS. 17 & 18.
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROW BODY, MODEL # AW-2- 32-AR-MVOLT-GEB10ISNOT USED
INSTALL NEW ACCESS PANEL- MATCH EXISTING SIZE.
PATCH EXISTING CEILING & PAINT
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
INSTALL NEW SS TRESHOLD SADDLE-SEE DETAIL 4/A201
9
19
20
21
28
10
29
30
INTERIOR UPGRADE OF EXISTING RESTROOMS INCLUDES:
1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
BOYS GIRLS
330
"x48
"
30"x
48"
4
BOYSGIRLS
ABCD
GIRLS
BOYS
ABCD
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
11/4" = 1'-0"
BOYS & GIRLS RESTROOM REMODEL PLAN
21/4" = 1'-0"
BOYS & GIRLS RESTROOM DEMO PLAN
41/4" = 1'-0"
BOYS RESTROOM INTERIOR ELEVATIONS
31/4" = 1'-0"
GIRLS RESTROOM INTERIOR ELEVATIONSN.T.S.
SITE PLAN
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGDIMENSIONS AND CONDITIONS, AND NOTIFY ARCHITECTOF ANY CONFLICTS/ DISCREPANCIES.
2. ANY ITEMS INDICATED AS DEMOLITION WITHIN AREA OFWORK SHALL BE DEMOLISHED OR REMOVED UNLESSNOTED OTHERWISE. DEMOLITION SHALL INCLUDE ITEMSSPECIFIED BELOW. MATERIALS, EQUIPMENT AND FINISHESSCHEDULED TO BE REMOVED SHALL BE STORED FORREUSE OR DISPOSED OF AS DIRECTED BY THE OWNER.
3. DEMOLISH/ REMOVE & PATCH EXISTING MATERIALS,ITEMS, OR FINISHES AS REQUIRED TO PERFORM NEWWORK WHERE INDICATED. MATCH EXISTINGWALL/FLOOR/CEILING TO MATCH ADJACENTMATERIALS/FINISHES UNLESS NOTED OTHERWISE.
4. ALL ABANDONED PLUMBING LINES, ELECTRICAL, CONDUITOR BOXES, A/C DUCTS OR DIFFUSERS AND TELEPHONECABLES SHALL BE REMOVED BACK TO CLOSEST FEEDERPOINT, AND PROPERLY CAPPED, SEALED, ETC.
5. ALL (E) ELECTRICAL SWITCHES & OUTLETS ARE TO BE RELOCATED & REWIRED TO MEET ACCESSIBILITY REQUIREMENTS AS NOTED ON PLANS.
6. ALL FLOORS SHALL BE PATCHED & LEVELED PRIOR TOINSTALLATION OF FINISH FLOORING. FLOOR SLOPES INRESTROOM SHALL NOT EXCEED 2%.
7. ACCESSORIES AND FIXTURES SCHEDULED, SHALL MATCHTHE INGLEWOOD USD STANDARD- SEE SPECIFICATION.
8. SEE SHEET A201, DETAILS 3 & 5, FOR TOILET FIXTURE &ACCESSORY MOUNTING HEIGHT REQUIREMENTS AND CLEARANCES. PROVIDE BACKING AS REQUIRED FORFIXTURES, PARTITIONS AND ACCESSORIES PERMANUFACTURERS TECHNICAL DATA SHEETS AND DETAILSINCLUDED ON SHEET A201.
9. SEE MANUFACTURERS TECHNICAL DATA SHEETS ANDRECOMMENDATIONS FOR FRAMING TO MAINTAINACCESSIBLE HEIGHTS AND CLEARANCES. NOTIFY THEARCHITECT OF ANY CONFLICTS/ DISCREPANCIES PRIOR TOFRAMING OR MOUNTING OF ANY ACCESSORIES.
10. TOILET FLUSH LEVER MUST BE LOCATED ON THE WIDESIDE OF THE ROOM, AWAY FROM THE INSIDE WALL ANDNARROW SIDE OF THE ROOM. CONTROLS SHALL BEOPERABLE WITH ONE HAND, & SHALL NOT REQUIRETIGHT GRASPING, PINCHING, OR TWISTING. THE FORCEREQUIRED TO ACTIVATE CONTROL SHALL BE NO GREATERTHAN 5 POUNDS (22.2 N) FORCE, PER CBC SECTION1127A.2.3
11. PROVIDE ALL NEW ACCESS PANELS IN-KIND TO REPLACEEXISTING AT SAME LOCATION- SEE SPEC.
GENERAL NOTES
LEGEND
(E) WALLS OR SITE ITEMS TO REMAIN
(E) WALLS OR SITE ITEMS TO BEREMOVED
(E) FIXTURE TOBE REMOVED
NEW FIXTURETO BE INSTALLED
ACCESSORY SCHEDULE(SEE SPEC FOR ACCESSORY & FIXTURE PRODUCTS)
GB-1
GB-2
HD-1
MI
PTD
SD-1
LAV
TLT
GRAB BAR-HORIZONTAL 36", 1 1/4" DIA.SEE A201/ DET. 11GRAB BAR-HORIZONTAL 42"/48", 1 1/4" DIA.SEE A201/ DET. 11
SURFACE MOUNTED ELECTRIC HAND DRYER
LAVATORY
MIRROR WITH STAINLESS STEEL CHANNEL FRAME& SHELF 40" TO BOTTOM OF REFLECTIVESURFACE OF MIRROR
SURFACE MOUNTED SOAP DISPENSER
TOILET
SURFACE MOUNTED PAPER TOWEL DISPENSER
SURFACE MOUNTED SEAT COVER DISPENSERTSCD
TPH
TS
WR
SND
MCU-1
PTDWR
UR
TOILET TISSUE DISPENSER
TOILET PARTITION
SURFACE MOUNTED WASTE RECEPTACLE
RECESSED PAPER TOWEL DISPENSER ANDWASTE RECEPTACLE
RECESSED MEN'S COMBINATION UNIT
URINAL
SURFACE MOUNTED SANITARY NAPKINDISPENSER
FD FLOOR DRAIN
NEW TILE FINISHSEE 17/ A201
51/4" = 1'-0"
BOYS & GIRLS RESTROOM CEILING PLAN
DEMO (E) EPOXY FLOOR FINISH FOR NEW WORK & VINYLBASE MATERIAL
DEMO (E) TOILET FIXTURE
DEMO (E) LAVATORY
DEMO (E) TOILET PARTITION, INCLUDING ALL HARDWARE
REMOVE ALL TOILET ACCESSORIES, INCLUDING HARDWARE
DEMO (E) GRAB BARS, INCLUDING ALL HARDWARE
DEMO (E) FRP PANEL WAINSCOT
DEMO (E) URINAL
NOT USED
DEMO (E) WALL FINISH TO FRAMING
KEYNOTES(APPLY ONLY AS REFERENCED ON THIS SHEET)
2
3
4
16
5
17
1
6
7
8
11
12
13
18
22
14
15
23
24
25
26
27
DEMO (E) LIGHTING FIXTURES & ASSOCIATED HARDWARE
NOT USED
NOT USED
DEMO EXHAUST FAN. INSTALL (N) FAN & GRILLE. MATCH SIZE
DOOR, HARDWARE & THRESHOLD TO REMAIN. PAINT DOOR
NOT USED
NOT USED
(E) PLUMBING CHASE WALL TO REMAIN
REVISE TOP OF SWITCH PLATE HEIGHT TO +48 AFF
INSTALL NEW HOSE BIBB FIXTURE AT NEW LOCATION.
NOT USED
PIPE WRAPS AT ALL EXPOSED LAVATORY PIPES
INSTALL NEW EPOXY FLOOR FINISH W/ VINYL WALL BASE.4" VINYL BASE BY JOHNSONITE, COLOR BY ARCHITECT.
INSTALL NEW CERAMIC TILE WALL FINISH & CEMENTMORTAR. SEE A201/ DETS. 17 & 18.
INSTALL NEW LED LIGHT FIXTURE LITHONIA NARROW BODY, MODEL # AW-2- 32-AR-MVOLT-GEB10IS
NOT USED
NOT USED
PAINT EXISTING CEILING.
DISCONNECT EXISTING HAND DRYER FOR NEW WORK-REINSTALL/ RECONNECT AT EXISTING LOCATION.
9
19
20
21
28
10
29
SCOPE OF WORK
6EXISTING SITE PHOTO
AREA OF WORK
A117
DEMO & REMODEL RESTROOM FLOOR, CEILING PLANS &
ELEVATIONS
HILLCREST HIGH SCHOOL
RESTROOM INTERIOR
UPGRADE
INTERIOR UPGRADE OF EXISTING RESTROOMS INCLUDES:
1. REPLACE EXISTING TILE FLOORS AND TILE WALL FINISHES.
2. REPAIR AND REPAINT EXISTING PLASTER OR GYPSUM BOARD CEILING.
3.REPLACE NEW TOILET FIXTURES AT EXISTING LOCATIONS, U.N.O.
4.REPLACE NEW LAVATORY FIXTURES AT EXISTING LOCATIONS, U.N.O.
5. CLEAR/SNAKE EXISTING DRAIN LINES FOR 100 LINEAR FEET TOWARDS MAIN LINE.
6.REPLACE TOILET PARTITIONS AND ALL RESTROOM ACCESSORIES.
7. REPLACE EXISTING LIGHT FIXTURES WITH NEW LED LIGHT FIXTURES AT SAME LOCATION.
8.REPLACE EXISTING VENTILATION SYSTEM EQUIPMENT; CLEAN AIR GRILLES.
9.EXISTING WINDOW, DOOR, AND THRESHOLD TO REMAIN AND PROTECT IN PLACE, U.N.O.
WALL OR ADJACENTPARTITION (WHEREOCCURS)
MIRROR,CENTEREDON LAVATORY
FLUSHACTIVATORON WIDE SIDE
WALL OR
WALL OR PARTITION
FLOOR OR WALLMOUNTEDWATER CLOSET
TOP OF
14"
15" MIN WHERE ADJACENTPARTITION IS <24" DEEP18" MIN WHERE ADJACENTPARTITION IS >24" DEEP
30"X48" LEVEL ANDCLEAR FLOOR SPACE
LAVATORY
Paper TowelDispensers
ElectricHand Dryer
Urinal Front ViewLavatory Plan MirrorSoap andTowel DispensersLavatory Front ViewLavatory
Water Closet Plan Toilet Tissue DispenserA B C D E F
G H J K L PN Urinal
Water Closet
Q R S T U V
PROVIDE PRE-MOLDEDINSULATIONON SUPPLYAND DRAIN LINES
SOAPDISPENSERSEE "U"
PAPER TOWELDISPENSERSEE "Q"
Sanitary NapkinDisposal
ALIGN WITHFRONT OFWATER CLOSET
RECESSED AS REQUIRED(3" MAXIMUM PROJECTION)
SanitaryNapkinVendor
GRAB BARGRAB GRAB
Side Grab BarFlush ValveToilet
Side Grab BarTank Type ToiletC.1 D.1
REQUIRED 30"X48" LEVELAND CLEAR SPACE
ADJACENT WALLOR PARTITION
RIM OR COUNTER
BOTTOM OF APRON
KNEE CLEARANCE
LAVATORY,WHERE OCCURS
TOILET SEAT COVERDISPENSER, SEE "S"
"V"
"S"
"S"
28" m
in
2'-0" min
"N" "O
" 24"
52" min (in stall)54" min (not in stall)
12"max
"P"
"W"
3" max projection
3'-4" min
12" min
1 1/
2" m
in
52" min (in stall)54" min (not in stall)
12"max
"P"
24"
3'-4" min
12" min
1 1/
2" m
in
3" max projection
12" max
1 1/
2" m
in
"P"
36" max
"Q"
36"
19" m
in
"S"
alig
n w
ith to
p of
sea
t
19" max
18" m
in
18" min
36" m
ax"T
""U
"27
"
9" m
ax
8" min kneeclearance
6" max toeclearance
3'-0"
18"min
8" m
axbo
wl d
epth
"T" "S
"
"S"
12" 6"
<24"
>24"
15
20" to 24" max
"W"
3'-6" min
4'-0" min 4'-0" min
6"max
6" max
18
48" A
dult
(36"
at G
rade
s K
-5)
(Side View)(Side View)
(Side View)
2" CLR
12" max 42" min52" min
36" m
in6" max
BAR
SEAT
PARTITIONWALL OR
GRAB BAR
PARTITION
BAR
FLUSHACTIVATORON WIDE SIDE
(WHERE OCCURS0
M Urinal Plan
13"-
15"
Partition
PartitionFlush valveon wide side
Partition
Outward Swing SelfClising Door
clea
r ope
ning
clear opening
Partition or face of wall
48"min 48" clr. min
60" m
in42" m
in
24" m
in32
" min
4" m
ax
32" m
in
60" min.
97" MIN. (IN SWING DOOR WITH FLOOR MOUNTED WC)
Flush valveon wide side
60" m
in42" m
in32
" min
18" min
34" min
36" min
42" min.12" max.
60" min.
32" m
in.
18" c
lr. 36" w
ide
36"
94" MIN. (IN SWING DOOR WITH WALL MOUNTED WC)
Partition or face of wallPartition or face of wall
18" c
lr.
18" c
lr.
2'-0" 2'-0" 2'-0"
1"4"
1"
1-1/2"1-1/2"
BACKING PLATE: 2 X 6 WOOD TUBING: 11/4" Ø X 18 GA. WALL. 18-8 TYPE 304STAINLESS STEEL, W/ 180 GRIT SATINFINISH. FLANGES: 3" ROUND 14 GA.S.S. WITH 1/4" SCREW HOLES AND A 20GA. STEEL WITH 1/4" SCREW HOLES TOMATCH FLANGES, TO EQUAL WALLFINISH THICKNESS.
GRAB BARS: MODEL Q-36 (OR Q-42) / CS-1,BY TUBULAR SPECIALITIES MANUFACTURNGINC. LOS ANGELES , CA. 90061
ALTERNATE: PROVIDE ADDITIONAL BLOCKING ONMETAL STUDS AS INDICATED TO PROVIDE ENDATTACHMENT TO STUDS TO REPLACE BLOCKING.
#10 X 3" S.S. VANDAL PROOFSCREWS @ WOOD STUDS.2"x#10 S.S. VANDAL PROOFSCREWS @ METAL STUDS.
(E) WALL TILE OR PLASTER
WOOD / METAL STUDS
1-1/2" DIA. GRAB BAR W/ FLANGE
SNAP-LOCK FLANGE11 GA. 18-8 TYPE 304 STAINLESS STEELPLATE W/ 180 GRIT SATIN FINISH.
TOILET PARTITIONS
3" DIA. STAINLESS STEEL BACK PLATESW/ STUDS1-1/2" DIA. GRAB BAR W/ FLANGE
SNAP-LOCK FLANGE
# 10 STAINLESS STEEL MACHINESCREWS
(N) 2 X 6 WOOD BLKGTYPICAL SIMPSONFRAMING ANCHOR A-35
SEE PLAN FOR ADDITIONALDIMENSIONAL REQUIREMENTS
TYPE A - TOILET PARTITION CONNECTION TYPE B - WOOD / METAL STUD CONNECTION
GRAB BAR SUPPORT CONNECTION GRAB BAR SUPPORT CONNECTION
1 2"
4" or 5"
1/4"
max
.
TILE- FULLHEIGHT
TILE- WAINSCOT A201
MOUNTING HEIGHTAND DETAILS
626 666 3940 fax626 666 6906
155 South Fair Oaks, 2nd FloorPasadena CA 91105
53/8" = 1'-0"
FIXTURES AND ACCESSORIES MOUNTING HEIGHT
"W"
"X"
"V"
"O"
"P"
"Q"
"S"
"T"
"U"
"Y"
NOTES:
1. ROUGH-IN FOR FIXTURES, EQUIPMENT AND APPLIANCES SHALL BE AS INDICATED ONDRAWINGS AND AS SPECIFIED, INCLUDING THOSE ITEMS INDICATED AS FURNISHED BYOTHERS, FURNISHED BY OWNER, OR FUTURE CAPACITY. M WHEN CONNECTIONS TOEQUIPMENT FROM CAPPED OR PLUGGED LINES ARE REQUIRED, CAPS OR PLUGS SHALL BEREMOVED AT TIME EQUIPMENT IS SET AND STOPS OR VALVES INSTALLED AND CON-NECTIONS PROVIDED AS SPECIFIED.
2. UNLESS OTHERWISE INDICATED, FIXTURES SHALL BE INSTALLED WITH 5/16 INCH BRASSBOLTS OR SCREWS OF SUFFICIENT LENGTH TO SECURE FIXTURE TO BACKING, WALL ORCLOSET RINGS.
3. FIXTURES INSTALLED AGAINST CONCRETE OR MASONRY WALLS SHALL HAVE THEIR HAN-GERS FASTENED WITH THE 5/16" BOLTS, PHILIP SHIELD TYPE ANCHORS, OR 2 UNIT CINCHANCHORS. WOOD OR PLASTIC PLUGS ARE NOT PERMITTED.
4. BACKING FOR HANGING OF PLUMBING FIXTURE AND EQUIPMENT SHALL BE INSTALLED INSUPPORTING WALL AT TIMES ROUGH PIPING IS INSTALLED.
5. FOR WOOD STUDS USE STEEL PLATE 1/4" THICK, NOT LESS THAN 4 INCHES WIDE STEELPLATE SHALL BE ATTACHED TO STUD AT EACH END OF PLATE TO EACH STUD IT CROSSES.PLATE SHALL HAVE 2 PRE-DRILLED 1/8 INCH HOLES FOR NO.14 FLAT HEAD SCREWS 2INCHES IN LENGTH FORM EACH STUDS.
6. FOR METAL STUDS USE STEEL PLATE 1/4" THICK, NOT LESS THAN 4 INCHES WIDE STEELPLATE SHALL BE ATTACHED TO STUD AT EACH END OF PLATE TO EACH STUD IT CROSSES.PLATE SHALL BE ATTACHED TO METAL STUDS BY BOLTING WITH TWO 1/4" "U BOLTS" PERSTUD WITH BOLTS TROUGH PLATE AND AROUND STUD FLANGE OR BY WELDING WITH 1/8"FILLET WELD FULL WIDTH OF STUD FLANGE, TOP AND BOTTOM OF PLATE.
7. PIPING SHALL BE STUBBED OUT TO EXACT LOCATION OF FIXTURES AND STUBS SHALL BEINSTALLED SYMMETRICAL WITH FIXTURES. HOT AND COLD WATER SUPPLIES FOR CENTERSET FAUCETS ON LAVATORIES SHALL BE INSTALLED ON 8 INCH CENTERS, UNLESS OTHERWISE SPECIFIED OR REQUIRED.
8. FLUSH VALVE SHALL BE 1-1 2" CLR. FROM GRAB BAR.
ADULT/HIGHSCHOOLDESCRIPTION MIDDLE
SCHOOLELEMENTARY
SCHOOL
17"~19"
33"
19" MIN.
15"~17" 12"~15"
25"~27" 20"~25"
17"~19" 14"~17"
40" MAX. 36"~40" 36" MAX.
34" MAX. 29"~34" 29" MAX.
27" MIN. 24" MIN.24"~27"
17" MAX. 15" MAX.15"~17"
44" MAX. 37" MAX.37"~44"
36" MAX. 32" MAX.32"~36"
24" MIN.24"~27"27" MIN.
33/8" = 1'-0"
TYPICAL ACCESSIBLE TOILET LAYOUTS113/8" = 1'-0"
GRAB BAR DETAILS
46" = 1'-0"
DOOR THRESHOLD83/8" = 1'-0"
NON-BEARING FULL HEIGHT PARTITION
17RESTROOM TILE FINISH LAYOUT
19BACKING AT WOOD FRAMED WALL
RESTROOM INTERIORUPGRADE
MOUNTING HEIGHT REQUIREMENTS
TAG
*
(*SEE DETAIL 5 FOR TAG REFERENCES AND LOCATIONS)
203" = 1'-0"
BACKING AT BLACK CHANNEL IRON WALL
18RESTROOM TILE FINISH SCHEDULE