inhalable agents (gases, vapours, dusts and fumes) 1...reoxidation the stability and behavior...
TRANSCRIPT
10
1.4.5.1 Inhalable agents (gases, vapours, dusts and fumes) 1
• The production of iron and steel involves the consumption and generation, of a
variety of inhalable agents including, but not limited to, gases, vapours, dusts,
fumes, smokes and aerosols. These agents comprise a variety of toxicological hazards including irritants, chemical asphyxiants, fibrogens, allergens, carcinogens
and systemic toxicants.
• The pulmonary system (lungs) can be affected by exposure to harmful agents
through acute (short-term) injury to lung tissue, the development of pneumoconiosis, pulmonary dysfunction and the development of lung cancer. Certain
harmful agents that are inhaled through the lungs can cause target organ damage
and/or systemic toxic effects. Certain asphyxiants can cause death in a matter of seconds at high concentrations by displacing oxygen.
• Specific agents that may be found in the iron and steel industry include heavy metals (e.g. lead, chromium, zinc, nickel and manganese) in the form of fumes, particulates
and adsorbates on inert dust particles. Acid mists from pickling areas can cause skin, eye and respiratory irritation. It is important to consider the solubility of metals and their compounds when addressing risk.
1.4.5.2 Confined space
A confined space is one that is large enough for the worker to enter bodily, has limited or restricted means of entrance or exit and is not designed for continuous employee occupancy, on a space which may accumulate a hazard which is present.
Examples of temporary occupancy might entail a person performing repairs on a furnace or servicing a fuel tank or trailer, sump, silo or bunker. Employers should be especially vigilant about all OSH hazards that may exist in a confined space, in particular the buildup of toxic or flammable gases, oxygen displacement and engulfment. Confined spaces require
additional safety and health precautions because their configurations hinder the activities of any workers who must enter, work in and exit from them. A confined space often has poor air quality. In addition, many fatalities occur to rescue personnel who respond without
adequate planning and protection.
Control of hazardous energy
The iron and steel industry regularly uses different sources of energy (electric, mechanical, hydraulic, pneumatic, etc.). The safe control of energy should be addressed by procedure
and carried out by appropriately trained personnel in accordance with the nature of the energy source and the characteristics of the facilities. To the extent possible, the source of energy itself should be isolated rather than the control mechanism. Energy sources for
equipment should be turned off or disconnected or de-energized and the switch locked or labeled with a warning tag.
1.5 CONTROL MEASURES FOR ABOVE HAZARDS IN PROPOSED EXPANSION
Out of above mention hazards, various control measures suggested based on their cause of
failure are as under.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 141
11
1.5.1 Molten metal spillage and splashing
• Diligently examining and treating scrap, following induction furnace safety
procedures, properly training and retraining personnel, and use of automated melt
shop equipment, founders can be confident their operations are as safe as possible.
• Bridging can be minimized by using proper charge material and by making sure the
different sizes of charge material are added correctly. If a bridge occurs, power
must be turned off and the melt deck and surrounding areas evacuated
immediately until enough time has elapsed to allow the molten metal to solidify.
• Bridging may reveal itself with several warning signs. The clearest warning sign
that bridging has occurred is that the melt is taking longer than calculated. Rather
than increase the power, the operator should switch off power immediately. Under
no circumstance should the operator increase power.
• Many serious foundry accidents occur during furnace charging, when foundry
workers come in close proximity to the molten bath. Splashes caused by dropping
large pieces of scrap and water/molten metal explosions caused by wet or damp
scrap can be reduced through the use of drying and preheating systems and
remotely controlled charging systems.
• Appropriate Personal Protective Equipment (PPE) protects melt shop workers from
both metal splash and radiant heat.
• Do not allow water or hydraulic fluid to accumulate in the pit. It is designed to hold
molten metal in case of an emergency and must be kept clean and dry.
• Choosing appropriate refractory lining material and their additives / bonding
material.
• Proper installation of the lining is as important as selection of the right material. If
the material is inadequately compacted during installation, voids or areas of low
density may form, creating a weak spot easily attacked by molten metal. If the
crucible is created with a lining form that is improperly centered, or one that has
been somehow distorted during storage or shipment, lining thickness will be
uneven. As a result, the lining may fail before the end of its predicted service life.
• The refractory manufacturer’s procedures for installation, drying and sintering must
be followed. If sufficient time is not allowed for refractory materials to bond, the
lining will be more prone to molten metal and slag attack.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 142
12
• The entire furnace should be visually inspected whenever it is emptied. Special
attention should be paid to the high wear areas described above. Observations
should be logged.
• Follow refractory manufacturer’s instructions for lining inspection and maintenance.
• operators should be properly trained to identify unevenness in operation through
• Visual inspection
• Attainment of maximum power at a lower than normal applied voltage.
• In a fixed-frequency power supply, an increase in the number of capacitors
needed to be switched into the circuit to maintain unity power factor.
• In a variable-frequency power supply, running at a higher than normal frequency.
Useful though they may be, changes in electrical characteristics must never be
thought of or used as a substitute for physical inspection of the lining itself.
• A magnetic contact thermometer attached to the steel shell of a channel furnace
will indicate lining wear by revealing the position of a hot spot. Infrared
thermometers make it possible to remotely measure temperature by looking at a
furnace through the eyepiece of a device resembling a hand-held video camera.
State-of-theart, automatic lining-wear detection systems that display the lining
condition graphically are available also.
• Bulky material should be lowered into the furnace. If it must be “dump charged,”
be sure there is adequate charge material beneath the charge to cushion its
impact.
• In the event of a prolonged power failure, a loss of coolant or other prolonged
furnace shutdown, the furnace must be emptied.
• Avoid excessive superheating of the molten bath providing controller for
temperature
• When working with a cold holding furnace, be sure it is properly preheated to the
refractory manufacturer’s specifications before filling it with molten metal to avoid
thermal shock.
• Ground leak detection system should be provided.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 143
13
1.5.2 CONTROL MEASURES OF CARBON MONOXIDE POISONING & SPONG IRON
REOXIDATION
The stability and behavior characteristics of DRI depend on a number of variables affecting
the pore surface area. These include the mineralogy of the oxide ore or agglomerate,
reduction temperature, time at the reduction temperature, gas composition, age and
previous history of exposure and handling. As one example, the DRI stability increases with
reduction temperature because the pore surface area decreases as the temperature is
raised. Other methods of improving the stability involve making the iron in the pore
surfaces unavailable for reoxidation or decreasing the pore surface area mechanically.
Control measures for carbon monoxide poisoning is as under:
• Special precautions should be taken to protect workers who may be potentially
exposed to gases containing large concentrations of carbon monoxide, such as
blast furnace gas and coke oven gas.
• The employer, in cooperation with workers and their representatives, should
conduct a hazard analysis and risk assessment process to determine areas from
which gas containing carbon monoxide could escape and accumulate, especially in
areas using new technologies.
• Workers who may be exposed to these gases should be appropriately trained in
order to recognize the symptoms of carbon monoxide poisoning.
• Areas where carbon monoxide might collect in such a way as eventually to enter
work areas should be equipped with continuous automatic carbon monoxide
sensors and alarms to provide adequate early warning of dangerous gas releases.
• Continuous monitoring of exposure levels should be carried out. Workers who enter
areas with gas hazards should carry portable gas monitors. Workers who enter
areas where immediate danger to life or health (IDLH) exists should also be
equipped with self contained breathing apparatus (SCBA).
• Self-contained breathing apparatus and resuscitation equipment should be
maintained in readiness for the emergency rescue team, and operators should be
instructed in their use.
• Gas area rescue drills should be held on a regular basis.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 144
14
1.5.3 CONTROL MEASURES FOR HANDLING AND STORAGE OF FUELS
1.5.3.1 Control measures to be adopted during storage of coal
• LDO should be stored in a suitable steel tank designed, constructed, and operated
according to standards for the prevention and control of fire and explosion hazards.
• LDO should be used in closed system. Employee handled HSD during unloading of
the tankers should be trained for standard operating procedures.
• LDO should be stored as per supplier’s instruction and MSDS should be made
available at site.
• Safety shower and Eye wash fountains should be made available nearby the area
for flushing in case of exposure.
• Personal Protective Equipments like apron, gloves, safety goggles, etc. should be
provided and ensured to be worn during working. Use of PPE is enforced 100%.
• Typical label, Warning and safety phrases such as 'flammable', etc should be
marked where applicable.
• Movement in LDO storage area should be restricted and smoking should be strictly
prohibited.
• Good Housekeeping is maintained at the facility.
• The storage tanks should be secured in the open air, and sited at a distance of 5m
from adjacent building and the facility. Tanks are located away from other
storages.
• All measures should taken to prevent potential heat and ignition sources reaching
the storage area. Typical label, Warning and safety phrases such as 'flammable',
poison', etc are marked where applicable.
• To avoid static electricity buildup proper grounding and bonding (including formal
procedures for the use and maintenance of grounding connections) should be
provided and other safety procedures for loading and unloading of product to
transport systems
• Facilities are properly equipped with fire suppression equipment that meets
recognized technical specifications for the type and amount of flammable and
combustible materials stored at the facility. Portable fire extinguishers are
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 145
15
maintained and readily available at the storage site. Fire buckets filled with dry
sand are provided for fire controls. Fire hydrants systems are also installed at the
facility. Fires are handled by trained firefighters.
• Special trainings are given to the employees regarding fire fighting through
demonstration and mock drills and in case of emergency only trained person are
permitted to handle the fire.
• Emergency telephone numbers are posted in a permanent place.
1.5.3.2 Control measures to be adopted during storage of coal
• Moisture content maintained up to silo process by water sprinkling to prevent
dusting in crushing plant and conveyer belt area.
• Static earthling provision made on all powder handling equipments.
• Emergency stop pull stop wire provided on belt.
• Safe guardings are provided on moving part of the machines.
• Proper ventilation and air draft available at all site of the plant.
• No high temperature exposure to workers near owns due to charging and discharge
work carried out by machines.
• Air circulating within a coal pile should be restricted as it contributes to heating;
compacting helps seal air out.
• Moisture in coal contributes to spontaneous heating because it assists the oxidation
process and should be limited to 3%.
• Coal having high moisture content should be segregated and used as quickly as
possible. Efforts should be made to keep stored coal from being exposed to moisture.
• Dry coal shall be kept dry and shall be not exposed to any rain during storage
period. This concerns what is known as the heat-of-wetting;
• Drying coal is an endothermic process [heat is absorbed] and lowers the temperature
of the coal. Wetting (or gaining moisture) is an exothermic process and the liberated
heat can accelerate the spontaneous heating of the coal.
• Following the "first in, first out" rule of using stock reduces the chance for hot spots
by helping preclude heat buildup for portions of stock which remain undisturbed for a
long term. The design of coal storage bins is important in this regard.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 146
16
• A high ambient temperature aids the spontaneous heating process.
• Use coal as quickly as practicable. The longer large coal piles are allowed to sit, the
more time the spontaneous process has to work.
• The shape and composition of open stockpiles can help prevent fires. Dumping coal
into a big pile with a trestle or grab bucket can lead to problems. Rather, coal should
be packed in horizontal layers, which are then leveled by scraping and compacted by
rolling. This method helps distribute the coal evenly and thus avoids breakage and
segregation of fine coal. Segregation of coal particles by size should be strenuously
avoided, as it may allow more air to enter the pile and subsequent heating of finer
sizes.
• Properly inspect, test and maintain installed fire protection equipment.
• Maintain an update pre-fire plan and encourage regular visits to coal facilities by the
site or local emergency response force.
1.6 IDENTIFICATION OF HAZARDS BY FIRE AND EXPLOSION INDEX & TOXICITY
INDEX
Fire and Explosion Index (F&EI) is an important technique employed for hazards
identification process. Consequence analysis then quantifies the vulnerable zone for a
conceived incident. Once vulnerable zone is identified for an incident, measures can be
formulated to eliminate or reduce damage to plant and potential injury to personnel.
Rapid ranking of hazard of an entire installation, if it is small, or a portion of it, if it is large,
is often done to obtain a quick assessment of degree of the risk involved. The Dow Fire and
Explosion Index (F&EI) and Toxicity Index (TI) are the most popular methods for Rapid
Hazard Ranking. These are based on a formal systematized approach, mostly independent
of judgmental factors, for determining the relative magnitude of the hazards in an
installation using hazardous (inflammable, explosive and toxic) materials.
The steps involved in the determination of the F & EI and TI are:
� Selection of a pertinent process unit
� Determination of the Material Factor (MF)
� Determination of the Toxicity Factor (Th)
� Determination of the Supplement to Maximum Allowable Concentration
(Ts)
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 147
17
� Determination of the General Process Hazard Factor (GPH)
� Determination of the Special Process Hazard Factor (SPH)
� Determination of the F&EI value
� Determination of the TI value
� Determination of the Exposure Area
1.6.1 HAZARDOUS MATERIAL IDENTIFICATION METHODOLOGY
From the preliminary appraisal of Material Safety Data Sheet, it is observed that Light diesel
oil (LDO) is hazardous. F&EI and TI values have been computed for LDO storage tank.
In general, the higher is the value of material factor (MF), the more inflammable and
explosive is the material. Similarly, higher values of toxicity factor (Th) and supplement to
maximum allowable concentration (Ts) indicate higher toxicity of the material. The
tabulated values of MF, Th and Ts are given in Dows Fire and Explosion Index Hazard
Classification Guide. For compounds not listed in Dow reference, MF can be computed from
the knowledge of flammability and reactivity classification, Th can be computed from the
knowledge of the National Fire Protection Association (NFPA) Index and Ts can be obtained
from the knowledge of maximum allowable concentration (MAC) values. The MF, Th and Ts
values are respectively 10, 0 and 50 for LDO.
General process hazards (GPH) are computed by adding the penalties applied for the
various process factors.
Special process hazards (SPH) are computed by adding the penalties applied for the process
and natural factors.
Both General process hazards and Special process hazards corresponding to various process
and natural factors are used with MF to compute F&EI value and with Th and Ts to compute
TI value.
1.6.2 F&EI Computation
F&EI value computed for TPS and CTT from GPH and SPH values using the following formula
F&EI = MF x [1 + GPH (total)] x [1 + SPH (total)]
1.6.3 Toxicity Index (TI)
Toxicity index (TI) is computed from toxicity factor (Th) and supplement to maximum
allowable concentrations (Ts) using the following relationship:
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 148
18
TI = (Th + Ts) x [1 + GPH (total) + SPH (total)]/100
Calculation for F&EI as well as TI is given in table shown below for Natural gas, Mono
Ethelene Glycol and Coal.
Table 4: Fire and Explosion Index for LDO
FIRE AND EXPLOSION INDEX FOR LDO
Material Factor 10 Nf=2, Nr=0
1 GPH
Penalty
factor
range
Penalty factor
used Remark
Base factor 1.00 1.00 Base factor
A Exothermic reaction 0.3-1.25 0.00 No reaction
B Endothermic process 0.2-0.4 0.00 NA
C Material handling and transfer 0.2-1.05 0.40 NFPA 2
D Enclosed or Indoor process unit 0.25-0.9 0.00 Not Enclosed
E Access 0.2-0.35 0.00
Two side easy access
so NA
F Drainage & spill control 0.25-0.5 0.00
Proper dike design so
NA
General process Hazard factor F1 1.40
2 SPH
Penalty
factor
range
Penalty factor
used
Base factor 1.00 1.00
A Toxic material 0.2-0.8 0.2 0.2×1
B Sub atmospheric pressure(<500 mmhg) 0.5 0.00 NA
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 149
19
C Operation in or near flammable range
1 Tank farm storage flammable liquid 0.5 0.5
2 Process upset or purge failure 0.3
3 Always in flammable range 0.8
D Dust Explosion 0.25-2.0 0 NA
E Pressure 0.86-1.5 0 NA
F Low temperature 0.2-0.3 0 NA
G Quantity of flammable / unstable material
1 Liquid or gases in process 0.2-3 0 NA
2 Liquid or gases in storage 0.1-1.6 0.5
3
Combustible solid in storage, dust in
process 0.2-4
H Corrosion & Erosion 0.1-0.75 0.1 <0.005 in per year
I Leakage joint and packing 0.1-1.5 0.1
possibility of minor
leakage
J Use of fired equipment 0.1-1 0 NA
K Hot oil heat exchange system 0.15-1.15 0 NA
L Rotating equipment 0.5 0 NA
Special process Hazard F2 2.4
Process unit hazard factor(F1×F2)=F3 3.4
Fire and Explosion Index(F3×MF) 34
TOXICITY INDEX
Toxicity number Th 50 Nh=1
Penalty factor Ts 50 TLV more than 50 ppm
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 150
20
Toxicity Index 5
Table 5: Conclusion for Fire, Explosion & toxicity Index
Applicable Fire and Explosion index range
1-60 Light
61-96 Moderate
97-127 Intermediate
128-158 Heavy
>159 Sever
CONCLUSION FOR TOXICITY INDEX
Applicable Toxicity index range
1-5 Light
6-9 Moderate
above 10 High
Table 6: Fire and explosion index for coal
FIRE AND EXPLOSION INDEX FOR COAL
Material Factor 16 st-1, Nr-0
Penalty Penalty
1 GPH factor range factor used Remark
Base factor 1.00 1.00 Base factor
For ongoing oxidation
A Exothermic reaction 0.3-1.25 0.50 process
B Endothermic process 0.2-0.4 0.00 NA
C Material handling and transfer 0.2-1.05 0.40 NFPA 2
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 151
21
Enclosed or Indoor process
D unit 0.25-0.9 0.00 Proper ventilation
E Access 0.2-0.35 0.00 Two side easy access
F Drainage & spill control 0.25-0.5 0.00 Flash point not applicable
General process Hazard
factor F1 1.90
Penalty Penalty
2 SPH factor range factor used
Base factor 1.00 1.00
A Toxic material 0.2-0.8 0.40 0.2×2
Sub atmospheric
B pressure(<500 mmhg) 0.5 0.00
Operation in or near flamable
C range 0.00 No operation storage
Tank farm storage flammable
1 liquid 0.5
2 Process upset or purge failure 0.3
3 Always in flammable range 0.8
D Dust Explosion 0.25-2.0 0.5 150-175 micron
E pressure 0.86-1.5 0
F Low temperature 0.2-0.3 0
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 152
22
Quantity of flammable /
G unstable material
1 Liquid or gases in process 0.2-3 0
2 Liquid or gases in storage 0.1-1.6 0
Combustible solid in storage,
37200 MT Coal storage
3 dust in process 0.2-4 0.6
H Corrossion & Eroission 0.1-0.75 0
I Leakage joint and packing 0.1-1.5 0
J Use of fired equipment 0.1-1 0
K Hot oil heat exchange system 0.15-1.15 0
L Rotating equipment 0.5 0
Special process Hazard F2 2.50
Process unit hazard
factor(F1×F2)=F3 4.75
Fire and Explosion
Index(F3×MF) 76
Toxicity number Th 50 Nh=1
Penalty factor Ts 50 TLV 0.5 ppm
Toxicity Index 3.40
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 153
23
1.6.4 Hazards Ranking
Table 7: Hazards Ranking
Substance F&EI value TI value F&EI range TI range
LDO & FO 34 5 Light Light
COAL 76 3.4 Moderate Light
From the above various hazards identified from the proposed project activities are as under:
• Fire hazard due to handling and storage fuels.
• Fire and explosion hazard due to handling of molten metal
Other hazards are:
• Occupational health hazards
• Other hazards
Consequences of hazards also depend on prevailing meteorological conditions and density of
population in surrounding areas.
1.7 OCCUPATIONAL HEALTH AND SAFETY
During the project work lot of activities will be involved such as construction, erection,
testing, commissioning, operation and maintenance, the men, materials and machines are
the basic inputs. Along with the boons, the industrialization generally brings several
problems like occupational health and safety.
The following occupational health and safety issues are specific to proposed plant activities
will arise during project work as well as regular operation of plant:
� Physical hazards
� Radiation hazards
� Respiratory hazards
� Electrical hazards
� Noise
� Burial hazard
� Entrapment hazards
� Fire and explosions
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 154
24
1.7.1 Physical Hazards
Industry specific physical hazards are discussed below.
Potential physical hazards in proposed plant are related to handling heavy mechanical
transport (e.g. trucks) and work at heights (e.g. platforms, ladders, and stairs).
Heavy Loads / Rolling during construction phase
Lifting and moving heavy loads at elevated heights using hydraulic platforms and cranes
presents a significant occupational safety hazard. Recommended measures to prevent and
control potential worker injury include the following;
� Clear signage in all transport corridors and working areas;
� Appropriate design and layout of facilities to avoid crossover of different activities
and flow of processes;
� Implementation of specific load handling and lifting procedures, including:
� Description of load to be lifted (dimensions, weight, position of center of
gravity)
� Specifications of the lifting crane to be used (maximum lifted load,
dimensions)
� Train staff in the handling of lifting equipments and driving
mechanical transport devices
� The area of operation of fixed handling equipment (e.g. cranes, elevated platforms)
should not cross above worker and pre-assembly areas;
� Material and product handling should remain within restricted zones under
supervision;
� Regular maintenance and repair of lifting, electrical, and transport equipment
should be conducted.
� Use appropriate PPE (e.g. insulated gloves and shoes, goggles to protect against
radiation, and clothing to protect against heat radiation and liquid metal splashes);
� Install cooling ventilation to control extreme temperatures;
� Implement work rotations providing regular work breaks, access to a cool rest
area, and drinking water.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 155
25
Physical hazards in foundry operations may be related to handling of large, heavy, and hot
raw materials and product (e.g. charging of furnaces); accidents related to heavy
mechanical transport (e.g. trains, trucks and forklifts); injuries from grinding and cutting
activities (e.g. contact with scrap material ejected by machine-tools); and injuries due to
falls from elevation (e.g. high platforms, ladders, and stairs).
Product Handling
Prevention and control of injuries related to handling, grinding and cutting activities, and
use of scrap, include the following:
� Locate machine-tools at a safe distance from other work areas and from walkways.
� Individual, enclosed workplaces should be provided to prevent accidents resulting
from fettling or the use of grinders;
� Conduct regular inspection and repair of machine-tools, in particular protective
shields and safety devices / equipments;
� Provide rails along the transfer plate with interlocked gates that open only when
machin is not in use;
� Train staff to properly use machines-tools, and to use appropriate personal
protection equipment (PPE).
Heat and Hot Liquid Splashes
High temperatures and direct infrared (IR) radiation are common hazards in foundries. High
temperatures can cause fatigue and dehydration. Direct IR radiation also poses a risk to
sight. Contact with hot metal or hot water may result in severe burns. Recommended
measures for prevention and control of exposure to heat and hot liquids / materials include
the following:
� Shield surfaces where close contact with hot equipment or splashing from hot
materials is expected (e.g. in cupola furnaces, EAF, induction melting ladles, and
casting);
� Implement safety buffer zones to separate areas where hot materials and items
are handled or temporarily stored. Rail guards around those areas should be
provided, with interlocked gates to control access to areas during operations;
� Use appropriate PPE (e.g. insulated gloves and shoes, goggles to protect against IR
and ultraviolet radiation, and clothing to protect against heat radiation);
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 156
26
� Implement shorter shift durations for work in high air temperature environments.
Provide regular work breaks and access to drinking water for workers in hot areas;
� Install cooling ventilation to control extreme temperatures.
1.7.2 Radiation hazards
Workers may be exposed to gamma rays and related ionizing radiation exposure risks. The
following techniques may be used to limit the worker exposure risk:
� Gamma ray testing should be carried out in a controlled, restricted area using a
shielded collimator. No other activities should be undertaken in the testing area;
� All incoming scrap should be tested for radioactivity prior to use as feedstock
material;
� If the testing area is near the plant boundary, ultrasonic testing (UT) should be
considered as an alternative to gamma ray techniques;
� Regular maintenance and repair should be conducted on testing equipment,
including protective shields.
1.7.3 Respiratory Hazards
Dust and Gas
Dust generated in foundries includes iron and metallic dusts, which are present in melting,
casting and finishing shops; and wooden and sand dusts, which are present in the molding
shop. In the former, workers are exposed to iron oxide, and silica dust that may be
contaminated with heavy metals such as chromium (Cr), nickel (Ni), lead (Pb), and
manganese (Mn). The dust present in the melting and casting shops is generated by high
temperature operations, and the fine particle size, and potential metallurgical fumes,
creates a serious occupational inhalation risk. In the molding shop, workers are exposed to
sand dust, which may contain heavy metals, and wood dust, which may have carcinogenic
properties, particularly if hard wood is used. Recommendations to prevent exposure to gas
and dust include the following:
� Sources of dust and gases should be separated and enclosed;
� Design facility ventilation to maximize air circulation. Outlet air should be filtered
before discharge to the atmosphere;
� Exhaust ventilation should be installed at the significant point sources of dust and
gas emissions, particularly the melting shop;
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 157
27
� Use automated equipment, especially in the fettling process;
� Provide separated eating facilities that allow for washing before eating;
� Provide facilities that allow work clothes to be separated from personal clothes and
for showering / washing after work and before eating;
� Implement a policy for periodic personnel health checks.
� Respiratory hazard control technologies should be used when exposure cannot be
avoided with other means, such as operations for creating sand moulds; manual
operations such as grinding or use of non-enclosed machine-tools; and during
specific maintenance and repair operations.
Recommendations for respiratory protection include the following:
� Use of filter respirators when exposed to heavy dust (e.g. fettling works);
� For light, metallic dust and gases, fresh-air supplied respirators should be used.
� Alternatively, a complete facial gas mask (or an “overpressure” helmet) can be
used, equipped with electrical ventilation;
� For carbon monoxide (CO) exposure, detection equipment should be installed to
alert control rooms and local personnel. In case of emergency intervention in areas
with high levels of CO, workers should be provided with portable CO detectors, and
fresh-air supplied respirators.
Insulation Materials
The use of insulation material is widespread in foundries and handling of this material
during construction and maintenance may release fibers and present an occupational health
hazard. Asbestos and other mineral fibers widely used in older plants may expose people to
inhalation risks of cancer-causing substances. In order to limit releases, appropriate and
material specific work practices should be applied.
1.7.4 Electrical Hazards
Workers may be exposed to electrical hazards due to the presence of heavy-duty electrical
equipment in plant.
1.7.5 Noise
The foundry process generates noise from various sources, including scrap handling,
furnace charging and EAF melting, fuel burners, shakeout and mould / core shooting, and
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 158
28
transportation and ventilation systems. Recommended noise management techniques
include the following:
� Enclose the process buildings and / or insulate them;
� Cover and enclose scrap storage and handling areas, as well as shake out and
fettling processes;
� Enclose fans, insulate ventilation pipes and use dampers;
� Implement management controls, including limitation of scrap handling and
transport during nighttime. Noise abatement measures should achieve the ambient
noise levels
1.7.6 Explosion and Fire Hazards
Handling of liquid metal may generate a risk of explosion, melt run out, and burns,especially
if humidity is trapped in enclosed spaces and exposed to molten metal. Other hazards
include fires caused by melted metal, and the presence of liquid fuel and other flammable
chemicals. In addition, iron foundry slag may be highly reactive if calcium carbide is used to
desulfurize the iron. Recommended techniques to prevent and control explosion and fire
hazards include the following:
� Design facility layout to ensure adequate separation of flammable gas and oxygen
pipelines, and storage tanks, away from heat sources;
� Separate combustible materials and liquids from hot areas and sources of ignition
(e.g. electrical panels);
� Protect flammable gas and oxygen pipelines and tanks during “hot work’
maintenance activities;
� emergency preparedness and response.
1.8 OTHER HAZARDS AND ITS CONTROLS
� The other hazards possible at site are as given below:
Table 8: Other Hazards and Its Controls
Name of
possible
hazard or
emergency
Its source &
reason
Its effects on
person, property &
environment
Place of effect Control measures
provided
Building • Any natural • Injuries & • All building & • Structure stability
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 159
29
collapse
Earthquake
Calamities
• Week
structure
• Over
loading
Fatalities
• Building damage.
sheds of the
company as
given in the
Fac. layout
is by competent
person for all
structure.
• No overloading of
structures and
building.
Electrical
Installation
failure like
Transformer,
PCC etc.
• Overload
Loose
contacts
Short circuit
• Fire
• Suffocation of
persons inside the
plant
• Electrical
transformer
switch yard
• Electrical
MCC rooms
• Power plant
• Installation as per
electricity rules.
• Other Controls
provided
• Rubber mat
provided
• Earthing provision
1.9 OCCUPATIONAL HEALTH MONITORING PLAN
All the potential occupational hazardous work places would be monitored regularly. The
health of employees working in these areas would be monitored periodically for early
detection of any ailment due to exposure.
For Occupational Health monitoring following plan should be implemented :
Medical Surveillance:
All employees should be medically examined by Factory Medical officers once in two years to
ascertain the health status of all workers in respect of Occupational Health hazard to which
they are exposed.
Medical officer will prepare a list of hazardous area both area wise and trade wise Specific
tests are performed for identification of such occupational hazard. No person is employed to
operate a crane, locomotive or work-lift or give signals unless his eye sight and color vision
have been examined by qualified ophthalmologist.
Employee information and training:
The industry will provide training program for the employees to inform them of the following
aspects; hazards of operations, proper usage of nose mask and earplugs, the importance of
engineering controls and work practices associated with job assignment(s).
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 160
30
List of Tests to be conducted and recorded every two years:
1. Eyes 8. Ears
2. Respirator system 9. Circulatory system (Blood Pressure)
3. Abdomen 10. Nervous System
4. Locomotor System 11. Skin
5. Hernia 12. Hydrocele
6. Urine 13. Blood for ESR Report
7. Audiogram 14. Chest X Ray
Medical Examination:
The following medical checkup/examinations will be done:
1. Comprehensive Pre-employment medical checkup for all employees.
2. X-ray of chest to exclude pulmonary TB, Silicosis etc.
3. Spirometry test
4. Lung function test.
5. Audiometer test to find deafness.
6. Vision testing (Near and far as well as colour vision)
Schedule of medical examination:
The following schedule for medical checkup will be followed:
1. Comprehensive Pre-employment medical checkup for all employees.
2. Chest X- Ray once a year
3. Chest X- Ray for all other employees once every 3 years.
4. Spirometry & Lung function test for all employees once every 6 months.
5. Clinical examination of all employees once every 6 months.
6. Comprehensive medical examination of all the employees after retirement and all those
employees with more than 5 years of service leaving the company.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 161
31
Report of schedule medical examination:
Report of schedule medical examination should be published within the company and also
report to higher management with safety & health magazines published within the
company. Also workers whose schedule examinations are pending to be intimated through
their respective department heads to avoid any worker / employee left out for schedule
medical examination.
Plan and fund allocation for occupational health & safety:
Occupational health and safety plan should be prepared and to be reviewed periodically in
top management meeting.
Fund allocation should be made from annual budget for occupational health & safety which
should also include occupational health and safety facility for contract and casual workers.
1.10 WORK AREA MONITORING PLAN
Work area monitoring plan should be develop and implemented as per Factory rules for air
born contamination including cement and silica dust. Periodic air sampling to be carried out
and their testing results should be noted in form number 37 prescribed in Gujarat Factory
rule and record of the same should be maintained.
Work are also to be monitored for lighting, temperature and other ambient condition.
1.11 AUTOMATIC FIRE DETECTION AND CONTROL MEASURES
1.11.1 General
The plant's fire protection shall consist of structural solutions, fire extinguishing systems
and fire alarm systems. The fire extinguishing system shall consist of the fire water system
with fire pumps distribution pipelines, hydrant valves and fire hoses and the portable fire
extinguishers.
1.11.2 FIRE WATER SYSTEM
Separate fire water tank is proposed for firefighting system. Water will be taken from
Gujarat water Infrastructure Limited (GWIL) and from there water require for firefighting
will be taken to fire water tank for firefighting system.
Details of fire water reservoir are as under:
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 162
32
Table 9: Existing Fire tank capacity details
Sr no P Volume m3
1 Fire hydrant tank in captive power plant 740.25
2 Fire hydrant tank in spong process plant 275.25
Total 1015.5
Further fire water tank requirement for new plant will be reconsidered and installed.
1.11.3 Fire Water / Hydrant System
Fire pumps
There shall be two fire pumps, one electric and one diesel engine driven. The pumps supply
water for the fire line and the fixed fire extinguishing systems. Either of these centrifugal
pumps can alone deliver the required amount of water. At the rated flow, the pressure
produced by the pumps shall be adequate, at least 6 bar by the rated flow, and at a zero
flow not exceed 10 bar.
Jockey Pumps
An electric motor driven jockey pump will maintain automatically system pressure in the fire
line. In case of emergency main pump will be turned on manually.
Pressure switches located in the fire water main shall sense sudden drop of pressure below
set point, due to opening of any hydrant valves, which shall provide the starting signal to
the jokey pumps. For stopping of the pumps only manual arrangement shall be provided.
The run and fault alarms from the fire pumps are led to the control room. The pumps will be
located in pump house which shall be constructed by purchaser based on input from
supplier.
Diesel Engine
Diesel engine shall be equipped with an approved automatic auxiliary starting device having
a sufficient capacity for at least six starts of fire pump. The diesel pump shall have a fuel
tank containing sufficient fuel to enable the pump to run on full load for at least three hours.
Water distribution system
Fire piping shall be of MS Class “C” with supports for above ground lines. For underground
piping GI class “C” pipes with necessary fittings will be used. The piping will be externally
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 163
1
Disaster ManagementDisaster ManagementDisaster ManagementDisaster Management 1 DISASTER MANAGEMENT PLAN
Emergencies may occur due to many reasons. It may occur due to natural causes like
earthquake, cyclone, flood etc. It may occur due to malfunction of standard working
systems or practices. There can be no set criteria for assessing the gravity of a disaster in
the abstract since this depends to a large extent on the physical, economic and social
environment in which it occurs. What would be consider a major disaster in a developing
country, will be equipped to cope with the problems involved, may not mean more than a
temporary emergency elsewhere. However, all disasters bring in their wake similar
consequences that call for immediate action, whether at the local, national or international
level, for the rescue and relief of the victims. This includes the search for the dead and
injured, medical and social care, removal of the debris, the provision of temporary shelter
for the homeless, food, clothing and medical supplies, and the rapid re-establishment of
essential services.
1.1 OBJECTIVES OF DISASTER MANAGEMENT PLAN
The Disaster Management Plan (DMP) is aimed to ensure safety of life, protection of
environment, protection of installation, restoration of production and salvage operations in
this same order of priorities. For effective implementation of the Disaster Management Plan,
it will be widely circulated and personnel training through rehearsals/drills.
The Disaster Management Plan would reflect the probable consequential severalties of the
undesired event due to deteriorating conditions or through 'Knock on' effects. Further the
management will be able to demonstrate that their assessment of the consequences uses
good supporting evidence and is based on currently available and reliable information,
incident data from internal and external sources and if necessary the reports of outside
agencies.
To tackle the consequences of a major emergency inside the factory or immediate vicinity of
the factory, a Plan has been formulated and this planned emergency document is called
"Disaster Management Plan".
The objective of the Industrial Disaster Management Plan is to make use of the combined
resources of the plant and the outside services to achieve the following:
• Effect the rescue and medical treatment of casualties;
• Safeguard other people;
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 164
33
painted. The codes IS1239/IS 3589 will be followed. All underground pipes shall have
cathodic protection. Sufficient no of isolation valve shall be provided to Isolate the area in
case of maintenance. The diameter of the fire pipes shall be sufficient for the effective use
of at least two fire hoses. The pipes and hydrants will be so placed that the fire hoses may
be easily coupled to them.
Hydrants
Hydrant type Fire Protection System essentially shall consist of a network of piping and
hydrant valves- both indoor & outdoor. The distance between any two hydrants shall not be
more than 45 meters. Each hydrant shall be provided with a hose cabinet (mounted along
side the hydrant on a steel column, lockable type) containing two nos. of 15 M long hoses
and branch pipes/nozzles. For multi-stored office building, a wet riser tapped off from the
hydrant main, shall be provided for each stair case inside the stair case and on this riser
hydrant outlet with first aid hose reel connection shall be provided on each floor. Each
hydrant shall be provided with a wall/column mounted on hose cabinet containing two nos.
of hose and branch pipe/nozzle.
The number and position of the hydrants shall be such that spray from at least two hoses
with combined jet and water fog nozzles may reach any part of the engine hall or auxiliary
room and spray from one combined jet and water fog nozzles may reach any part of other
places. A hydrant unit inside the power house shall consist of two hose couplings of size
DN50, both equipped with a shutoff valve. There will be two couplings beside each other to
make it possible to use the water hose and mobile foam unit simultaneously. Some hydrants
shall also to be installed on an external wall, to allow the use of hoses outside a building.
Fire hoses shall be cotton and nylon jacket seamless woven and rot proofed material
equipped with quick couplings and adjustable water fog nozzles. Hose couplings and nozzles
throughout the fire line shall be completely interchangeable. Hose couplings shall be made
of a copper alloy or other approved material.
Hose length : 15 m
Hose diameter : 63 mm
Busting pressure test : 32 kg/cm2
Sixty fire hydrant equipments are place for existing facility and required other fire hydrant
equipments for upcoming plant will be reconsidered and installed.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 165
34
1.11.4 Fire Alarm And Detection System
Fire alarm and detection system is already installed for existing plant and will also be
installed for new plant.
Siren
A siren with minimum range of 300 m in addition to flashing lights & alarm bells shall be
provided.
1.11.5 Fire Extinguishing Equipment
Total 40 fire extinguishers are placed of various types in different part of existing plant. Fire
extinguishers will be installed for new plant as well after evaluating their requirement in
adequate numbers.
1.11.6 PPEs
Adequate numbers of personal protecting equipments such as helmets, safety shoes, helmet
with glasses, Asbestose leg guard , apron, noise mask, earplug, safety belts etc are already
provided in adequate numbers for existing facility.
1.12 NEAREST FIRE STATION
All contact numbers of nearest fire station should be displaced in control room so, that in
case of emergency they can be contacted without any delay.
Nearest fire station is situated at Bhachau , which is around 42 kms from the proposed sit
and it will take around 10 minutes for fire tenders to reach to the site.
1.13 MEDICAL CENTRE
Even though negligible accident occurs at the site since observation of necessary safety
requirements has to be strictly followed. However, first aid should be made available at the
site and a 24 hour standby vehicle (ambulance) should also be available at the site for quick
transfer of any injured personnel to the nearest hospital, in case an accident occurs and
medical emergency arises.
Tie up with Government Dispensary, Bhachau and ambulance facilities should be made and
their contact numbers should be displayed. Contact numbers of for hospital and doctors
working in the hospitals should be displayed in medical centre. Trained medical officer
should also be appointed for regular check up and management of medical facilities. The
Factories Medical Officer shall be M.B.B.S. with a certificate of Training in Industrial Health
of minimum three months recognized by state government.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 166
35
Pre employment medical examination shall be conducted and details should be provided in
form number 33 as per factory act. Medical centre should be operated round the clock for
attending emergency arising out of accidents, if any. All workers shall be medically tested
once in a year and at the end of his term of employment and details to be maintained in
form number 32 as per factory act. Medical records of all employees should be maintained.
A qualified industrial hygienist should also be appointed on contract / part time basis to
check and comply applicable standard related to industrial hygiene and health.
1.14 SAFETY ORGANIZATION AND ITS ACTIVITIES
1.14.1 Construction and Erection Phase
A qualified and experienced safety officer will be appointed. The responsibilities of the safety
officer includes identification of the hazardous conditions and unsafe acts of workers and
advise on corrective actions, conduct safety audit, organize training programs and provide
professional expert advice on various issues related to occupational safety and health. He is
also responsible to ensure compliance of Safety Rules/ Statutory Provisions. In addition to
employment of safety officer by Plant, every contractor, who employs more than 250
workers, will also employ one safety officer to ensure safety of the worker, in accordance
with the conditions of contract.
1.14.2 Operation and Maintenance Phase
On completion of construction phase, the posting of safety officers would be in accordance
with the requirement of Factories Act and their duties and responsibilities would be as
defined thereof.
1.14.3 Strengthening of HSE and Meeting by Safety and quality circle
In order to fully develop the capabilities of the employees in identification of hazardous
processes and improving safety and health, safety and quality circles would be constituted
in area of work. The circle normally will meet for about an hour fortnight.
1.14.4 Safety Training
Safety training would be provided by the Safety Officers with the assistance of faculty
members called from Corporate Center, Professional Safety Institutions and Universities. In
addition to regular employees, limited contractor labors would also be provided safety
training. To create safety awareness safety films would be shown to workers and leaflets.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 167
2
• Minimize damage to property and the environment;
• Initially contain and ultimately bring the incident under control;
• Identify any dead;
• Provide for the needs of relatives;
• Provide authoritative information to the news media;
• Secure the safe rehabilitation of affected area;
• Preserve relevant records and equipment for the subsequent inquiry into the cause
and circumstances of the Emergency.
In effect, it is to optimize operational efficiency to rescue, rehabilitation and render medical
help and to restore normalcy.
1.2 MAJOR CAUSES OF EMERGENCY
Disastrous incident could be a local one causing damage to plant, equipment and material
only or additionally affecting the persons working in the plant/industry or if more serious,
affecting the neighboring environment including human population. The first two categories
can be termed as “On- site Emergency” and the last one as an “Off-site Emergency”.
There are number of factors that can be considered as causes for disastrous situation or
emergencies.
A good process technology has to be engineered properly by following accepted standards
in design, if the hazards are to be minimized. Improper sizing of plant and equipment,
inadequate schemes, faulty choice of material of construction may lead to unsafe
conditions. Risk evaluation, Hazard analysis and Hazard & operability will be emphasized
made mandatory when engineering the proposed project.
1.3 EMERGENCY ACTION PLAN
The emergency action plan consists of:
1. Site Controller:
He will retain overall responsibility for the factory and its personnel. As soon as he is
informed of the emergency he shall proceed to the control room and meet the P&A.
Manager. His duties shall be:
i) Assess the magnitude of the situation and decide if staff needs to be evacuated
from their assembly points.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 168
3
ii) Exercise direct operational control over areas other than those affected.
iii) Maintain a continuous review of possible development and assess in
consultation with Incident Controller and other Key personnel as to whether
shutting down of the plant or any section of the plant and evacuation of
persons is required.
iv) Liaison with Senior Officials of Police, Fire Brigade, Directorate of Industrial
Safety & Health, provide advice on possible effects on areas outside the factory
premises.
v) Control rehabilitation of affected areas on discontinuation of emergency.
vi) Issue authorized statements to news media, and ensure that evidence is
preserved for inquiries to be conducted by statutory authorities.
2. Incident Controller:
On hearing of an emergency siren he will rush to the scene of the occurrence and
take overall charge and report to Site Controller. On arrival he will assess the scale
of emergency and decide if major emergency exists or is likely and inform the
Communication Officer accordingly.
(1) Direct all operations within the affected areas with the priorities for safety of
personnel minimize damage to the plant, property and minimize loss of
materials.
(2) Pending arrival of Site Controller, assume the duties of his post and, in
particular.
(3) (a) Direct the shutting down and evacuation of plant and areas likely to be
adversely affected by the emergency.
(b) Ensure that all Key personnel and outside help are called in.
(4) Provide advice and information to the Fire squad & Security Officer and the
local fire service as and when they arrive.
(5) Ensure that all non-essential workers/staff of the areas affected are evacuated
to the appropriate assembly points, and the areas are searched for casualties.
(6) In the event of failure of electric supply and internal telephones, set up
communication point and establish contact with Emergency Control Centre.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 169
4
(7) Report on all significant developments to the P & A manager.
(8) Have regard to the need for preservation of evidence so as to facilitate any
inquiry into the causes and circumstances, which caused or escalated the
emergency.
3. Human Resources Manager:
He will also work as liaison Officer and will be stationed at the Main Entrance (Security
Office near Main Gate) during the emergency. He will under the direction of the site
Controller handle police, press and other inquiries, receive reports from roll-call leaders
from assembly points and pass on the absentee information to the Incident Controller. His
responsibilities shall include -
(1) To ensure that casualties receive adequate attention, to arrange additional help if required and information relatives.
(2) To control traffic movements into the factory and ensuring that alternative transport is available when need arises.
(3) When emergency is prolonged, arrange for the relief of personnel and
organize refreshments / catering facility.
(4) From information received, advise the Site Controller of the situation, recommending (if necessary) evacuation of staff from assembly points.
(5) Recruit suitable staff to act as runners between the Incident Controller and
himself if the telephone and other system of communication fails due to whatsoever
reasons.
(6) Maintain prior agreed inventory in the control centre.
(7) In case of prolonged emergency involving risk to outside areas by wind-blown materials, contact local Meteorological Office to receive early notification of changes in weather conditions.
4. Security Officer:
On hearing alarm advice fire squad and security staff in the factory of the incident zone and
cancel the alarm. He will also announce through telephone or messengers to the HR
Manager, Incident Controller and Site Controller that incident has occurred in such and such
zone. He will open the gates nearest to the incident and stand by to direct the emergency
service.
On hearing the emergency alarm, he will immediately contact Site Controller and on his
advice call the local fire brigade. In case fire is discovered but no alarm is sounding he shall
receive information about location from the person discovering the fire and thereafter
immediately consult the Site Incident Controller and make announcement on telephone
telling the staff location of the incident and to evacuate to their assembly points. He will
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 170
5
continue to operate the switchboard advising the calls connected with the incident to the
Communications Officer.
5. Departmental Heads:
The Departmental head wherein the incident has taken place will report to Incident
Controller and provide assistance as required. They will decide which members of their staff
they require at the scene.
6. first-aid Teams:
The Personnel Manager shall keep in security the roll call lists for the fire and first-aid teams
on duty. Each Departmental Head for his shift-team appoints roll call leaders and first
aiders. Roll call leaders shall check their roles as members of the services report for
emergency duty. Names of any unaccounted for absentees will be informed to the Security
Officer.
Members of first-aid Teams will report to the Incident Controller on hearing of the alarm in
daytime. The Emergency vehicle driver, if safe to do so, shall collect the emergency vehicle
and park nearest to the scene of the incident. First aider shall inform the incident controller
that the Emergency Vehicle is leaving the site, giving the name of the patient and
destination i.e. hospital or doctor’s room and request the Incident Controller to inform the
destination (hospital, etc.) advising them about the casualties reaching there.
7. Factory Fire Squad Personnel:
The duty Fire fighting Squad under the command of the Security Officer shall be responsible
for fire fighting and rescue. On hearing the alarm, they shall proceed to the place of
incident. The men at security gate shall find out the location of the emergency and proceed
to the site of the occurrence. At the incident scene, a team members detailed for this
purpose will check squad members against roll-call sheet. At the site, all the squad
members will respond to the advice and information given by the Incident Controller On
arrival of the local fire brigade, they will also assist in fire-fighting work with the advice of
the Incident Controller.
1.4 ORGANIZATIONAL PLAN
The Organization Plan is a systematic list of persons in the emergency management team
and their functions before, during and after emergency. The disaster management
organization shall be capable of quick response at any time of the day or night to meet the
emergency condition, both for ON- SITE as well as OFF-SITE. The plan given a detailed
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 171
6
chain of command, area of responsibility of each personnel involved in the plan, the
information flow pattern to be followed and co-ordination activities required to tackle the
emergency.
The Disaster Management Organization and functions proposed for an emergency situation
is as follows:
It can be seen from Disaster Management Organization that Chief Emergency Coordinator
shall take charge of the whole situation and shall guide the various coordinators to contain
and control the incident. Various activities are to be carried out by pre- designated key
personnel (Coordinators) and their team in quickest possible time.
The names, residential addresses and telephone numbers of key personnel shall be clearly
written in Disaster Management Manual as well as widely circulated in ECC, different control
rooms. It is to be noted that first few minutes after start of the incident is most vital in
prevention of its escalation.
Pre-emergency Actions
The proposed preventive and pre-emptive measures are as follows:-
• Ensure implementation of Disaster Planning.
• Ensure that all drafted for emergency undergo regular training and are prepared for
tackling emergency/disaster.
• Ensure that Mock Drills are performed under simulated emergency condition at
regular intervals to assess the strength and weaknesses of the response team/plan.
• Ensure awareness among employees through regular training.
• Ensure good liaison with all agencies and industries in the neighborhood for getting
help if situation arises.
• Ensure adequate stock of safety, personal protective appliances in good working
condition.
• Ensure awareness amongst public in the neighboring areas.
1.5 EMERGENCY CONTROL CENTRE
For the purpose of handling emergency, the following Emergency Control Centres has been
identified.
• During normal working hours - The Administrative Office
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 172
7
• During other times - The Security Office.
All communications to and from will originate at this CONTROL CENTRE. The Emergency
Control Center will have the following: -
a) A copy of ON-SITE EMERGENCY PLAN.
b) List of important telephone numbers such as Police, Fire
Brigade, Hospitals, and other outside Emergency Services, etc. (Refer Annexure B).
c) List of key Personnel with addresses and telephone numbers. (Refer Annexure C).
d) List of Fire and Rescue Squad Members (Refer Annexure E).
e) Plant layout indicating storage of hazardous materials
f) List Fire Extinguisher. (Refer Annexure G).
G) Fire Fighting System (layout of Fire Hydrants)
H) List of Personal Protective Equipment (Refer Annexure H)
I) First Aid box.
CODIFICATION OF SIRENS
Table 1:Condition of Sirens
Sr. SIRENS INDICATES AUTHORITY
1. 1 MINUTE
CONTINOUS
ON SITE
EMERGENCY (ALERT)
INCIDENT CONTROLLER
2. 30 SECOND
CONTINOUS
EMERGENCY
CONTROLLED
(ALL CLEAR)
SITE CONTROLLER
NOTE: 1) EMERGENCY SIREN TO BE SOUNDED ONLY IF REQUIRED
2) ALL EMPLOYEES IN AREAS OTHER THAN AFFECTED TO CONTINUE WORK UNLESS
EMERGENCY SIREN IS BLOWN.
3) NO EMERGENCY ORGANIZATION MEMBER WILL LEAVE THE EMERGENCY
SPOT UNLESS `ALL CLEAR’ SIREN BLOWN.
4) EMERGENCY SIREN IS TESTED ON EVERY SATURDAY AT 11:30 AM
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 173
8
Medical Services
The doctors in the nearby hospitals should be trained for treatment of personnel affected.
Necessary apparatus and drugs should also be available in first aid post and in State
Hospitals and also other Nursing Homes nearby. Manager (HR-Welfare) should have good
liaison with authorities of nearby hospitals and Nursing Homes as well as doctors outside so
that help may be available when required.
Transport and Communication
Ambulance Van will be available inside plant premises. The disaster management cell will
have the contact number of nearby hospitals or nursing home with Ambulance facility to call
them in case of emergency.
Assembly Point
In case of an EMERGENCY the employees should assemble near the defined Assembly Points, as indicated below: -
* In Front of Admin Office
Wind direction to be determined by the WIND SOCKS installed on top of the Admin
Building. THE EMPLOYEES SHOULD RUN PERPENDICULAR TO THE WIND
DIRECTION AND NOT AGAINST / ALONG THE WIND DIRECTION.
Emergency Shelter
Emergency shelter places shall be chosen sufficiently away from likely affected site.
Employees who are not in the emergency management team shall be asked to take shelter.
The place is chosen such that the employees taking shelter are not affected by fire or
explosion. More than one emergency shelter shall be designated so that proper shelter point
can be chosen depending on wind direction and other factors.
Wind Socks
Windsocks shall be provided on the top of tall buildings to indicate the wind direction.
Mock drills
• Inform all the employees about mock drill.
• Fix the date for mock drill.
• Observers will not be involved in the exercise. They will monitor the Mock drill.
• Emergency Siren / alarm will be raised.
• After hearing the Siren / alarm, Emergency procedure will be followed as mentioned
in the OSEP.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 174
9
• Observer will note down the activities with respect to the time.
1.6 FIRE SERVICES PERSONNEL
Fire service shall be manned by trained fire safety personnel. Fire services department shall
have adequate number of safety equipment for use during emergency. The list of safety
appliances is as follows:
• Gas Mask
• Asbestos Suit
• Fire Proximity Suit
• BA Set
• Electric Gloves (for 15000 volts)
• Hydraulic Tool
• Telephone
• Emergency Ladder, etc.
1.7 SAFETY AND PERSONAL PROTECTIVE APPLIANCES
Safety and personal protective appliances shall be provided in adequate numbers and shall
be distributed in different sections according to requirement. A list of such
appliances are as under:
• Industrial safety helmets
• Crash helmets
• Face shield with replacement acrylic vision
• Zero power plain goggles with cut type filters on both ends
• Zero power goggles with cut type filters on both sides and blue colour glasses
• Welders equipment for eye and face protection
• Cylindrical type earplug
• Ear plugs
• Canister gas masks
• Self contained breathing apparatus
• Leather apron
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 175
10
• Boiler suit
• Safety belt / line man’s safety belt
• Leather hand gloves
• Asbestos hand gloves
• Canvas cum leather hand gloves with leather palm
• Industrial safety shoes with steel toe
• Electrical safety shoes without steel toe and gum boots
• Heat resistant protective clothing - headgear, footwear, face shields, aprons, fire retardant
spats, coats and gaiters
• Eye protection with side shields
• Special UV and infra-red glasses
1.8 EMERGENCY ACTIONS
EMERGENCY WARNING
Communication of emergency would be made familiar to the personnel inside the plant and
people outside. An emergency warning system would be established.
EMERGENCY SHUT DOWN
There are number of facilities which can be provided to help in dealing with hazard
conditions. The suggested arrangements are
• Stop feed
• Deluge contents
• Remove heat
• Transfer contents
Methods of removing additional heat include removal the normal cooling arrangements or
use of an emergency cooling system. Cooling facilities which is vaporizing liquid may be
particularly effective since a large increase in vaporization can be obtained by dropping
pressure.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 176
11
EVACUATION OF PERSONNEL
There would have adequate number of exits and staircases. In the event of an emergency,
unconnected personnel have to escape to assembly point. Operators have to take
emergency shutdown procedure and escape. Time office maintains a copy of deployment of
employees in each shift at emergency communication centre. If necessary, persons can be
evacuated by rescue teams.
ALL CLEAR SIGNAL
At the end of emergency, after discussing with incident controllers and emergency
coordinators, the site controller orders an all clear signal.
1.9 HEALTH AND SAFETY MONITORING PLAN
All the potential occupational hazardous work places would be monitored regularly. The
health of employees working in these areas would be monitored once in a year for early
detection of any ailment. First aid centers and medical centre should be provided.
Transportation arrangement should be provided in case of emergency.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 177
Annexure 14: Land use studyAnnexure 14: Land use studyAnnexure 14: Land use studyAnnexure 14: Land use study
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 178
Satellite Data Analysis and Interpretation within 10 Km Area for Integrated Steel Plant of ASR Multimetals Pvt. Ltd. located at Chhadawada village of Bhachau taluka of Kachchh district, Gujarat Submitted To: DeTox Corporation Pvt. Ltd., Surat
Prepared By: Enviro-GIS Services, Vadodara
Submission Date: 7th December, 2015
Vondh Village
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 179
December, 2015 Enviro-GIS Service
Land use/cover study 2
1. Introduction and Background
1.1 Project Proponent ASR Multimetals Private Limited is a state-of-the-art Manufacturing unit of high
strength deformed steel Re-bars and Structural Steel Sections. ASR is fully equipped
to ensure quality at every stage of production, so as to deliver perfect product.
Modern and appropriate machinery, testing and quality checks along with qualified
operators make the task easy for the company to deliver the best every time.
The Group has a very strong presence in the various market of the country
domestically and a number of destinations abroad including Asia, Middle East,
Europe and Africa. The domestic market is also well aware of the brand “ASR” which
will give a further pushup to the marketing concern.
In order to meet the market demands, the company now propose to install a new
integrated steel plant and power plant at Survey no. 394/2, 398, 399 & 400,
394/1(P), 395, 397 Village: Chhadawada, Bhachau, District: Kutch (Gujarat)..
1.2 Project Information
Now the company proposes for expansion in their existing manufacturing capacity.
Company has procured additional land for the same. The Extended product profile is
as mentioned in Table 1.
Table 1: Product Profile for proposed Expansion Name of Products /By
Products & Intermediate Products
Existing quantity
Proposed quantity
MT/month
Total quantity MT/month
MS (MILD STEEL) Rods 5000 MT/Month
24000 MT/Month
36000 MT/Month
MS (MILD STEEL) Wires 2500 MT/Month
MS (MILD STEEL) Flats 2500 MT/Month
Re-Rolled Steel Products of MS (i.e. Channels, Angles Bars, Rounds, Sections & Profiles etc.)
2000 MT/Month
Steel Billets / Ingots (Semi Finished Products)
12333 MT/Month
24000 MT/Month (Along with
36333 MT/Month
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 180
December, 2015 Enviro-GIS Service
Land use/cover study 3
Preheater & LRF) Sponge Iron 5500
MT/Month 15000 MT/Month 20500 MT/Month
Power from AFBC Boiler (Coal Base)
4 MW 17 MW 21 MW
Power from WHRB (Waste Heat Gases from Rotary Kiln)
4 MW 8 MW 12 MW
1.3 Regulatory Framework The project fall under category A, section 3 (a) and 1 (d) of EIA notification
September 2006 and amendment thereof vide notification no. S.O 3067 (E) dated
1st December 2009.
1.4 Need of project and its importance to the country and or region
In order to meet the increasing demand of steel product in domestic as well as
international market the company proposes for an integrated steel plant.
1.5 Process details The production process of sponge iron involves four steps namely;
i. Raw material preparation plant: The raw material preparation plant consists of
crushers and screens through which the seized material required for process
is prepared. Normally, jaw crushers are used for iron ore crushing and roll or
impact crushers for coal. The feeding for the crushers are done through the
conveyors and vibrating feeders.
ii. Stock house: The stock house consists of the raw material storage bins;
which store material up to 24 hours plant requirement. There are four bins one
each for iron ore, feed coal, dolomite and injection coal. The raw materials are
fed into a rotary kiln through the volumetric/weigh feeders at a predetermined
rate.
iii. Reduction kiln: The processing of the materials consists mainly of kiln and
cooler system. The iron ore is pre-heated and reduced in a rotary kiln and
passes to the rotary cooler; where it gets cooled. The cooled material is then
passes to the belt conveyor; where the cooler discharge is fed to the product
house conveyor. The material is then led to the product separation circuit. An
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 181
December, 2015 Enviro-GIS Service
Land use/cover study 4
intermediate bin is provided to take care of any eventualities occurring due to
breakdown of the product separation circuit.
iv. Product separation plant: In the product separation section, the sponge iron
and the coal-char (un-burnt coal) are separated. The cooler discharge
material is screened to different sizes, and fed into magnetic separator. The
sponge iron is magnetic and hence, it gets attracted to the magnet present in
the magnetic separator and is discharged to separate bins the dust in the hot
gases settles and gets cleaned.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 182
December, 2015 Enviro-GIS Service
Land use/cover study 5
2. Study Area & Classification System
2.1 STUDY AREA The study area is within 10 km radius from center point of expansion project of ASR.
located at Chhadavada village of Bhachau taluka of Kachchh district. Area covers
total around 21 villages of Bhachau taluka mentioned above as shown in the Map 1.
Figure also depicts the major roads passing through the study area. The boundary of
the village locations has been derived from the Census of India maps 2011.
3.1.1 Classification of Land use and Land cover The classification system followed for land use/cover classification was same as
published by National Remote Sensing Agency (NRSA), Government of India, in the
year 1988-89. This is two level of classification system with seven classes in first
levels. This system of classification requires some modification and made to include
additional sub-categories which are more relevant in describing the land use/cover
for a particular study area. A synopsis of the classification is summarized and
presented in Table 2.
Table 2: Synopsis of Land use/cover Classification System
S. No. First Level Classification Second Level Classification
1. Built-up Land or Habitation Residential / Commercial Industrial
2. Agricultural Land Crop Land Fallow Land Plantations
3. Forests
Evergreen / Semi-Evergreen Forests Deciduous Forests Close Forests Open Forests Degraded Forest or Scrub Forest Blank Forest Plantations Mangroves
4. Wastelands Salt-Affected Land Waterlogged Land Marshy / Swampy Land / Mud Land Area
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 183
December, 2015 Enviro-GIS Service
Land use/cover study 6
S. No. First Level Classification Second Level Classification Gullied / Ravenous Land Land without Scrub Sandy Area (Coastal and Desertic) Barren Rocky / Stony Waste / Sheet Rock Area
5. Water Bodies Reservoir / Lakes / Ponds / Tanks
River Beds
6. Others Shifting Cultivation Grassland / Grazing Land Snow Covered / Glacial Area
7. Vegetation Cover
Scrub Open vegetation Close vegetation Mangroves
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 184
December, 2015 Enviro-GIS Service
Land use/cover study 7
3. Methodology & Ground Survey
3.1 METHODOLOGY DeTox Corporation Pvt. Ltd., Surat had entrusted the work to carry out - Satellite
Data Analysis and Interpretation for within 10 Km Area of ASR Multimetals Pvt. Ltd..
project site at Chhadavada village of Bhachau taluka, Kachchh district. To achieve
above objective following methodology was employed for preparation of land
use/cover report.
• Study and collection of relevant documents and maps
• Interpretation of satellite data
• Field Survey / Ground Truthing
• Generation of final land use and land cover map
• Impact assessment and mitigation measure suggestions
3.1.1 Study and collection of relevant documents and maps
Primary Data Collection The land use/land cover mapping was carried out using digital satellite imagery
procured from NRSA, Hyderabad. Details of the satellite data are as given in table 3
as under:
Table 3: Details of Satellite Data
Satellite Sensor Bands Year
Resourcesat 2
(91-56 A)
LISS IV 2,3,4 25th November,
2013
Secondary Data Collection
The ancillary data collected for the study were District planning series maps and
Census maps as base information for interpretation.
3.1.2 Interpretation of satellite data The study area was demarcated within the 10 km radius of the project site using
buffer option on the ancillary map collected. Satellite data was imported using
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 185
December, 2015 Enviro-GIS Service
Land use/cover study 8
importing of data, option and clubbing the three layers into the single layer for
interpretation. The data was in standard projection system universally followed as
UTM.
Considering the basic elements of interpretation such as tone, size, shape, texture,
pattern, location, association, shadow, aspect and resolution along with ground truth
and ancillary information collected during the preliminary reconnaissance survey the
interpretation was accomplished. The classification scheme followed in the project
was according to NRSA classification system as mentioned in previous chapter.
3.1.3 Ground truth study Ground truth study comprises of data collection of ground features along with the
respective geographical position in terms of latitudes and longitudes with GPS. Using
all the collected information the data was interpreted. A detailed ground truth was
carried out to check the discrepancy of the interpreted data. This comprises of
respective geographical positions in terms of latitudes and longitude of ground
features.
3.1.4 Final Map preparation The proportional presence of different land uses and land cover in terms of statistical
percentages was derived for the study area. Appropriate legends were used to
represent the various categories of land use and land cover, and were then written
on the prepared land use and land cover maps.
3.2 GROUND SURVEY The field survey was carried out around radial distance of 10 km from the project
site; the site was visited on 3rd June, 2014 for quality check of the map.
GPS readings were taken during the surveys wherever it was felt that additional
confirmation in interpretation of the data and also observations of land features were
noted. Additionally, spot checks were also done to confirm the land use / land cover
interpretation even where confidence of interpretation was high. Table 4 enumerates
the land features and its corresponding GPS readings of all the ground truthing
locations selected.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 186
December, 2015 Enviro-GIS Service
Land use/cover study 9
Table 4: GPS Readings within Study Area
Sr. No. Latitude Longitude Village Site
1. 230 18’ 00.2” 700 23’ 59.3” Vondh Village
2. 230 18’ 12.0” 700 23’ 59.2” Vondh Pond
3. 230 19’ 02.4” 700 24’ 17.5” Vondh Ag land Fallow
4. 230 19’ 09.1” 700 26’ 02.0” Vondh Canal work in progress
5. 230 19’ 18.2” 700 25’ 28.3” Vijpasar Habitation
6. 230 19’ 20.1” 700 25’ 25.1” Vijpasar Vegetation Cover
7. 230 19’ 27.2” 700 25’ 25.7” Vijpasar Pond
8. 230 22’ 15.6” 700 26’ 28.5” Ramapar old Pond
9. 230 23’ 29.4” 700 26’ 33.5” Ramapar old Ag field
10. 230 23’ 34.6” 700 29’ 57.6” Nr. Adoi River
11. 230 23’ 29.8” 700 30’ 12.7” Nr. Adoi Mango plantation
12. 230 20’ 49.1” 700 34’ 41.8” Lakadia Village
13. 230 18’ 28.4” 700 30’ 51.1” Samakhiyali- highway
Cement works machinery
14. 230 18’ 23.2” 700 30’ 29.1” Samakhiyali Pond
15. 230 18’ 42.0” 700 28’ 15.4” Chhadvada ASR factory
16. 230 19’ 14.1” 700 32’ 31.6” Lakadiya Scrubland
17. 230 15’ 01.3” 700 29’ 39.7” Amaliyara Pond
18. 230 16’ 29.3” 700 27’ 04.5” Chhadavada Open Vegetation inbetween Scrub
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 187
December, 2015 Enviro-GIS Service
Land use/cover study 10
4. Land Use/Cover Pattern of the Study Area
The land use and land cover in the region comprises of five first level classes and
nine second level classes as given in Table 5 below.
Table 5: Land use/cover Classification
S. No. First Level Classification Second Level Classification
1. Built-up Land or Habitation Residential / Commercial
Industrial
2. Agricultural Land Crop Land / Fallow land
Plantation
3. Wastelands Barren land
4. Water Bodies
Water body (Reservoir / Lakes / Ponds /
Tanks)
River bed
5. Vegetation Cover Scrub
Open vegetation
The image was classified into the above mentioned classes for different regions of
interest are given in Map 2. The photo documentation is as given in Annexure1. Brief
description of each type of the class forming land use and land cover, derived from
the remote sensing data analysis and the ground observations are explained below.
4.1 HABITATION
There were 21 villages covered within the study area.
4.2 INDUSTRIAL AREA
There were few industries along the Samakhiyari highway and in rest of the area
there were mostly solar plant.
4.3 AGRICULTURE
The agricultural land covered major region in the study area which covers 82 per
cent of the study area. The major crop cultivated in the study area was Green gram
(Vigna radiata), castor (Ricinus Communis), cotton (Gossypium spp.), Guvar
(Cyamopsis tetragonolobus), Til (Sesamum indicum) during rainy season. Mostly in
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 188
December, 2015 Enviro-GIS Service
Land use/cover study 11
summer castor and fodder crop are grown and at places bajra. Jeera (Cuminum
cyminum), Fenugreek (Trigonella foenum-graecum), and Mustard (Brassica juncea)
during winters. The irrigation is essentially through rainwater and at places dam, well
and bore water was used which goes upto 250 feets.
4.4 PLANTATION
Plantation area covers just 23 hectares of land which was at Adhoi village and was
of Mangifera sp.
4.5 BARREN LAND These are lands having no vegetation having bluish tone on data was segregated as
barren land, covering 0.21 sq.km. of land.
4.6 WATER BODY The area covered by natural or impounded inland fresh water lakes, ponds, or other
inland impoundments covered by water was designated as water bodies. They were
well distributed in the region.
4.7 RIVER BED Two rivers flows through the region, they are non-perennial rivers. In the northern
region there was Adhoi nadi.
4.8 SCRUB There are areas having sparse vegetation it is mainly covered by grasses these
areas are delineated as Scrub. As per the classification based on Forest Survey of
India the category denotes land having bushes and poor tree growth with canopy
density less than 10 percent. The Scrub category covered only 7.1 percent of the
area dominated by ravenous region along rivers and the base of the hillocks.
4.9 OPEN VEGETATION The vegetation category Open was segregated based on the canopy density of 10 to
20 per cent. Open Vegetation was seen mostly near coastal area.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 189
December, 2015 Enviro-GIS Service
Land use/cover study 12
4.10 AREA STATISTICS OF LAND USE/ COVER CLASSES
The area statistics of these classes are presented in Table 6. The major portion of
the study region is covered by agriculture, scrub, and open vegetation respectively in
descending order of the area covered.
Table 6: Land use/cover Classes Area Statistics within 10 km Radius of Project Site
Sr. No. Class Area (Ha.) Area (sq. km.) Area (%)
1. Habitation 473.01 4.73 1.51
2. Industrial Area 230.56 2.31 0.73
3. Agriculture Land 25783.74 257.84 82.11
4. Plantation 23.20 0.23 0.07
5. Barren Land 21.40 0.21 0.07
6. Water Body 272.63 2.73 0.87
7. River bed 180.73 1.81 0.58
8. Scrub 2237.54 22.38 7.13
9. Open Vegetation 2177.19 21.77 6.93
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 190
December, 2015 Enviro-GIS Service
Land use/cover study 13
5. Environmental Impacts and Suggested Mitigation Measures
5.1 Identification of Impacting Activities for the Proposed Project
The environmental aspects and impacts have been identified based on an
assessment of environmental aspects associated with the project. Potential impacts
on land use and land cover are given in Table 7.
Table 7: Aspect – Impact Identification
5.2 Land Acquisition
The present project is brown field project i.e. within the factory premises so no
requirement of land acquisition.
5.3 Construction Phase
Site Preparation leading to change in land use / cover
The present project is expansion project of Sponge Iron, Steel Billets, Rolling Mill
products and Power plant which is within factory premises. So this activity will not
have any direct impact on the land use/ cover pattern.
S. No.
Project Activities / Aspects
Potential Environmental Impacts on Land use Land cover (LU/LC)
C1 C2 C3
1 Land Acquisition
1.1 Land lease or purchase of
project site Brown field project so no land acquisition
2 Site preparation 2.1 Site preparation Change in land use/cover
3 Approach Road 3.1 Approach road Use of existing infrastructure
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 191
December, 2015 Enviro-GIS Service
Land use/cover study 14
5.4 Approach Road
It has been studied that existing approach road which is Samakhiyali highway will be
sufficient even if there will be new establishment. So there will not be land take area
for preparing access roads.
Considering the above impact as well as the operating and other conditions
mentioned above, there is no direct impact on land use/cover pattern of the present
expansion project.
There are few suggested mitigation measures though there is not direct impact of the
present project on land use/cover pattern.
Table 8: Environment Management Program
Impacting Activities and Aspect that will impact land use/cover
Mitigation Measures and Rationale
Implementation and Management
Remarks Location Timing Respon
sibility Monitoring Records
Site Preparation – change in LULC
The vegetation cover clearing should only be done on which construction is to take place and less disturbing the vegetation in adjacent areas
Within the demarcated project site area
Once ASR Approvals from Environmental division
Record of clearing of land and its area
-
The compensatory green cover to be developed.
Within the demarcated project site area
Once during construction activity
ASR Regular monitoring
Record of growth of species
-
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 192
December, 2015 Enviro-GIS Service
Land use/cover study 15
Annexure 1
PHOTO DOCUMENTATION
Photo1: Scrub At Lakadiya Photo 2: Fodder Crop At Adhoi
Photo 3: Open Vegetation At Chhavada Photo 4: Industrial Area at Samakhiyari
Photo 5: Adhoi River Photo 6: Water body at Vondh
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 193
December, 2015 Enviro-GIS Service
Land use/cover study 16
Annexure 2: Impact Scoring Methodology The steps in identifying environmental impact follow.
1. Scoring the Impact Severity / Consequence The consequences on various environmental receptors have been ranked into 5 levels ranging from insignificant to extreme consequence and are given inTable 1. Table 1: Impact Scoring System – Consequence Assessment
S. No.
Environmental Component Impacted
Impact and Score1
Insignificant (+/-) 1 point
Minor (+/-) 2 points
Moderate (+/-) 3 points
Major (+/-) 4 points
Extreme (+/-) 5 points
C1 C2 C3 C4 C5 C6 C7
Duration
1.
Land use / land cover (Average Score to be taken based on Duration, Extent and Intensity)
Very short term (upto 1 year)
Short term (>1 - 3 years)
Medium term (>3 - 5 years)
Long term (> 5-10 years)
Very long term (>10 years)
Extent (Area affected)
2. Very Limited (Within core zone)
Limited (<1 km around core zone)
Medium Range >1 – 3.0 km around core zone)
Long Range (>3 – 7 kms around core zone)
Extensive (>7.0 kms around core zone)
Effect on land use classes
3. Non-agricultural land
Scrub land Water body
Agricultural land & Vegetation Cover
Forest Area
2. Quantifying the Probability of Occurrence of the Impact After identifying the consequence severity as shown in Table 1, the probability of occurrence also needs to be estimated to arrive at a complete picture of environmental impact. Table 2 provides probability / likelihood ratings on a scale of 1-5. These ratings are used for estimating the likelihood of each occurrence.
1 In case none of the impacts are applicable, then Not Applicable (NA) is written in the appropriate cell.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 194
December, 2015 Enviro-GIS Service
Land use/cover study 17
Table 2: Probability of Occurrence Description Environment/Health and Safety Probability
Frequent Will happen every time during the project activity 5 Often Occur several times during the project activity 4 Likely Might occur at least once during the project activity 3
Possible Might occur during the project activity 2 Rare Very rarely encountered during the project activity 1
3. Identifying Activities Causing Unacceptable Levels of Environmental Impact Environmental impacts are now clubbed into four levels from extreme to low impact activities. Extreme impact activities are unacceptable and therefore need to be either stopped or modified such that they are brought to a lower level of environmental impact. This is summarized in Table .
Table 3: Environmental Impact Categorization
Scoring Negative Impacts (-)
Colour Code and Score
Range Type of Risk Inference
>20 Extremely Severe Activity should not proceed in current
form
14-20 Very Severe
Activity should be modified to
include remedial planning and
actions and be subject to detailed
ecological assessment
8-13 Moderately Severe
Activity can operate subject to management and / or modification
4-8 Less Severe
No action required unless
escalation of risk is possible
1-3 Minor / Negligible Negligible Risk of activity
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 195
Annexure 15: Socio Economic StudyAnnexure 15: Socio Economic StudyAnnexure 15: Socio Economic StudyAnnexure 15: Socio Economic Study
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 196
1
SocioSocioSocioSocio----Economic Environment Study ReportEconomic Environment Study ReportEconomic Environment Study ReportEconomic Environment Study Report 1 INTRODUCTION
The present report is a part of the Environmental Assessment Report for the proposed
project of Sponge iron, Steel billets, TMT, Power Plant (AFBC) at Village: Chhadawada,
Taluka: Bhachau, District: Kutch, Gujarat. The project is proposed by ASR Multimetals Pvt.
Ltd.
The present report prepared by Prof. Dilip Shah (retired) and Head of the Department of
Rural Studies, Veer Narmad South Gujarat University, who has been accredited as
Functional Area Expert in Socio Economic aspects by NABET and work for Detox Corporation
Pvt. Ltd. who has prepared the Environment Impact Assessment Report.
The basic objective of the study is to focus on Socio Economic Environment and Impact of
the Project. On the basis of the preliminary study of the Project design and field visit to the
project area and interactive field study. It is an attempt to sketch the Socio Economic
Environment and positive and negative impact and issues of proposed project on has been
recorded on the basis of interactive dialog with project area village community.
Appropriate suggestions are made to mitigate the issues arising out of the study and
satisfactory, sustainable and feasible Socio Economic development plan is suggested.
Necessary documents are presented in the appendix of the Report.
2 METHODOLOGICAL STEPS
The present report is carefully prepared with systemic methodological steps with Social
science related principles and techniques.
Long experience of present author of the report is also usefully related. These
methodological steps are as follow:
• We had first internal meeting with Project coordinator to understand the techno
economic aspects of the project under consideration of impact assessment.
• We had tried to satisfy the need of the total assessment study as our study will be
the components of the total Study.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 197
2
• We had first meeting with Project proponent’s representative to understand their
views and CSR activities and plans of the project.
• We have spent enough time to do full study of Project coverings all aspects of such
productive investment, inputs-outputs, processes, provisions of acquiring basic
inputs like land, water etc. and use of local resources including infrastructure.
Potential benefits to project area due to the project and provisions to satisfy
mitigation measures and development funds.
• Our office assistant collected secondary data useful to understand that Socio
economic Environment.
• However to get the real idea of the Socio economic environment and people’s
perception of the project, we have a pointed an agency to work under our direct
guidance of the functional area expert to collect most important Socio economic
primary data, interactive dialogs etc.
• On the basis of Available information facts and data, we had done analysis in four
parts:
a) Emerging Socio economic environment of the project area
b) People’s perception of the project
c) Mitigation Steps
d) Development Activities Plan
3 SOURCE OF DATA
Our present study is based on the all available and relevant sources of Secondary and
Primary data. Both the type of data is used either for supplement, Complement and
sometimes cross check the validity.
Technical data and related understanding of the project have been provided by internal
discussion as well as Project Proposal.
4 PROJECT NATURE AND SCOPE OF THE PROJECT RELATED INPUTS-OUTPUTS
ASR Multimetals Pvt Ltd. is located in Chhadawada village of Bhachau Taluka, District of
Kutch. It is an integrated Steel and Power Plant operative since March 2005.
Rolling mill products include MS Rods, Wires, and Flats, Steel angels, bars, rounds etc. and
Steel billets/Ingots. The brief description of nature of product states that it falls under the
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 198
3
category A Section (3) and 1(d) of EIA Notification Sept,2006 and amendment there of vide
notification no S.O.3067 (E) dated 1st December 2009.
The proposed project is Expansion Project. It is forward and backward integration project to
meet the in-house requirement of the raw material as well as the market demand and
supply gaps.
Estimated Project cost is Rs. 250 Crores. The land is already acquired when established the
manufacturing unit. There is 94433 Sq. m total land plot area out of which 50433 is be
industrial plot area while 3100 Sq. m green belt for proposed expansion project, company
would also allocate 6000 Sq. M residential area. There is no forest, National Park, Wild life
sanctuary area in 10 km radius of the project boundary.
Drinking water and industrial water and for domestic use will be obtained from Gujarat
water infrastructure limited (GWIL). 1000 m3/day will be used without use of ground or
surface water will not be used for construction etc. Electricity power will not be made
available from SEB grid but also from Captive Power Plant and D.G Sets.
The Social infrastructure is available from 3.9 km away human settlement from project site.
A basic community like primary health center, School communication and road network for
transportation is available in the vicinity.
The analysis of sources of land, water, social infrastructure sources shows that it will not be
extra burden on local supply as land is also acquired. Water is ensured from established
agency since (GWIC) new population will be almost insignificant as the project will be run by
local residents to a large extend.
5 SOCIO-ECONOMIC ENVIRONMENT
Socio Economic Environment is benchmark scenario of social and economic structure and
their relevant aspects. This benchmark status provides us idea of the development status,
development constraints and development potential of project area village and residing
people.
Socio Economic Environment data collected from the field study focusing on their project
area Villages Samakhiyari, Chhadawada and Vijpasara.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 199
4
Development status of the villages are not same Samakhiyali is relatively better while other
two villages are relatively less developed in terms of Social Development and even
economic well being we may state basic observations based on the field study to reflect on
the Social economic status.
5.1 EDUCATION:
Education level of the villages is not same. Samakhiyali has 73.14% literacy while
Chhadawada and project is established is having 49% and Vijpasara has 56% literacy level.
It means more than 50% are not literate at all.
5.2 HEALTH STATUS:
Though people are poor but their understanding of health care is appreciable. However,
except Samakhiyari health care infrastructure do not exists. Samakhiyali has Sub centre
and own private clinic, however, even small villages do have private clinics but unaffordable
hence, have to travel away to Samakhiyali.
5.3 LIVELY HOOD SOURCES:
The means to support to survival is mainly available from there sources directly Agricultural
and Cultivation. Agricultural labour and wage labour in other sectors on an average 60%,
20% and 15% people get their income from agriculture, Agri-labour and other wage labour
in relatively better. Village Samakhiyali 50% Chhadwada people are in Agri 20% in Agri
labour while 20% in wage labour in non-farm sector Vijpasar has much as much 70%
occupied in Agricultural and 20% in Agri labour but only 5% in non-farm labour. It may be
noted that overall income generated is hardly adequate.
The employment and income are highly seasonal. The 5-10% people are lucky to get
private job, 10% jobs are provide Chhadwada due to industrial unit. Average wage is Rs.
150-200 per day in Agriculture while they get Rs. 250-300 per day based on the skill in the
private sector, however since 90% are very tiny farmer and belong to weaker sectors.
Animal husbandry mostly constitutes milk production of cows and buffaloes based on
homemade inputs, however, 50-60% villages do sell milk to private dairy.
Sanitation and drinking water are minimum need of the community. The position of these
villages is such that out of these two villages deserve much attention. For example,
Samakhiyali and Chhadwada have over head tanks and complete system of drinking water
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 200
5
with septic tanks and household connections with assesses source of underground tank and
ponds. Vijpasar has got deprived of such facilities. So far as facility and use of toilets have
concerned, Samakhiyali has 80% individual household toilets while Chhadwada and Vijpasar
have only 15 to 20% toilets respectively.
Thus we can observe that two project villages are very poor in all aspects but samakhiyali is
little better in terms of development status and development constrains.
Development Potential of the project areas could be located in terms of the following:
− Infrastructure
− Institutional Support
− Women Empowerment
5.3.1 Infrastructure
Infrastructure is basis of development. The position of these villages are very good, good &
worst in respect to Samakhiyali, Chhadwada and Vijpasar.
Roads, electricity and transport (Bus+ Shared Auto) are very good in case of 1st village
samakhiyali but very poor in other two villages. Two villages are not having 100%
electricity.
5.3.2 Benefits of Government Schemes
Though people’s awareness of the programme is less, it is reported that government
scheme benefits are available to the villages. They could get the results and benefits Indira
Awas, Sardar Awas Yojana, Thus villages are not ignored by the government.
5.3.3 Women Empowerment
Though women empowerment in terms of economic social freedom is yet to be gained at
least in Samakhiyali, there is establishment of Self help group and they are yet banking
stage only. But given the opportunity women are ready to work for income generation
activity.
5.3.4 Institution of local self governance
Panchayats are working actively at least in major village Samakhiyali. It is potential to work
as a nodal agency and development of all the surrounding villages as it appears from their
suggestions with them.
Thus Socioeconomic environment is such that the development status, constrains and
potential are not same in three village in view of there size of population and location
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 201
6
Samakhiyali has better development and can take lead to assist the other two villages also.,
which are far smaller in terms of their populations as Samkhiyali has 10000, Chhadawada
has just 1953, while Vijpasar has only 876 population (A cluster of 12000 population of
these villages could be development unit)
6 VILLAGE PEOPLE’S PERCEPTION REGARDING PROJECT PROPONENT AND
PROJECT
The village people perception in the project area regarding ASR Company is positive as the
plant is already established and working since 2005.
The field survey provides at least five reasons for expected positive response of the people
towards expanded steel mill
• The project authority is quite liberal and has provided employment to local village
people and depended much less on non village labour except highly skilled ones. It
is expected that approx. 400-800 individual employment are already employed and
may be about 100-150 will get job out of expansion of the project.
• Social infrastructure of the area has got improved and well maintained due to use of
these infrastructures by company. A Plantation on road side done not only has
added beautification but also reduced erosion of the road sides.
• Project has provided funds to improve health awareness and medical assistance in
the primary health center.
• It is reported that the company is already spending Rs. 70 lacs for social welfare
activity.
• Finally it is reported in the field study that under C.S.R also company has provided
(a) Fodder to the Gaushala
(b) Committed fund of Rs. 2.5 lakh for construction of Toilets and
(c) In Chhadawada it has built up Protection wall on pond in 2015 which helps for
water Management and also adding some infrastructure values.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 202
7
7 MITIGATION ACTION PLANS
Our analysis shows that the question of the Rehabilitation and Resettlement plan is
irrelevant as no one get any displacement of any kind due to expansion of the project.
There are issues concerning Environment cost to be paid by the village on account of the
Project, however, the company has already committed specific measures to eliminate the
adverse environmental Impact. This is well documented in the Pre-feasibility report as
follow.
Table 1: EMP Budgetary Allocation
Environmental Issues Capital Cost (Rs. Lakh) Remarks
Air Pollution Control 250 The detailed plan will be
done by EIA Agency in EIA
Report.
Water Pollution Control 50
Noise Pollution Control 15
Environment Monitoring and
Management
7 per day
Occupational health 5 per day
Green Belt 12 per day
Total budgetary provision for
Environment Control
3.39
8 DEVELOPMENT ACTIVITY PLAN
We proposed the appropriate development action plan to the welfare of the villages’
community of project area villages i.e. Samakhiyali, Chhadawada & Vijpasar
During the field study, our research team had done interaction with respondent to identify
the development needs & the priorities to the villages.
Expected allocation of budget has also made clear in the prefeasibility report which may be
70 +30 lakhs rs. Thus One crore are available over a period of next two to five years to
meet the priority needs of villages communities, we may list out the following development
activity with estimated allocation of funds.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 203
8
Table 2: Expected allocation of budget in Development Activity
Sr
No.
Development Activities Maximum
Allocation (Rs.
Lakh)
Minimum
Allocation (Rs.
Lakh)
1 Employment & Income
generation through self help
groups
25 15
2 Toilet construction 25 15
3 Roads Maintenance & approach
Roads
10 05
4 Education Assistance to School 15 05
5 Health Awareness & Preventive
Action Support
15 05
6 Drainage Support Fund 10 05
Total Allocation(Rs. Lakh) 100.00 50.00
Implementation mechanism & the development activities could be suggested as follow,
i. Company should appoint responsible person with authority to co-ordinate the
development activities.
ii. A small village community Representation committee may be formulated for effective
participation of community & monitoring of works.
iii. An appropriate work plan is designed instead of casual demand driven activities.
iv. Regular quarterly meeting may be organized to monitor the works.
Conclusion:
The project proponent is well known to village community. Project is an expansion project &
due to positive perception of people with committed mitigation & development action plan.
The project is expected to contribute development of economy at both the ends rural as well
as urban.
Appendix: Detail Report of Field Based Socio economic Study.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 204
1
Name of the Project: Socio Economic Survey
ASR Multimetal Pvt.Ltd. (Kutch)
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 205
2
Covered Area:
District: Kutch
Taluka: Bhachau
Village: Samakhiyali
Chhadavada
Vijpasar
Vondh
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 206
3
Contents
1. Geographical Information .......................................................................................................................... 4
2. Study Design ................................................................................................................................................ 6
3. Data Findings based on FGD and Village Profile ....................................................................................... 7
Health ............................................................................................................................................................... 7
Education ......................................................................................................................................................... 7
Livelihood ......................................................................................................................................................... 8
Animal Husbandry ........................................................................................................................................... 9
Women Empowerment .................................................................................................................................. 9
Benefits of the government schemes .......................................................................................................... 10
Infrastructure facilities .................................................................................................................................. 10
Sanitation and Drinking water facilities ....................................................................................................... 11
Source of fuel ................................................................................................................................................. 12
4. Data Findings based on individual interaction and FGD with the community members .................... 13
CSR Activities ................................................................................................................................................. 13
Needs to be focused for the development.................................................................................................. 15
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 207
4
1. Geographical Information
Study was conducted in 1 district of the Gujarat namely kutch Total 1 taluka and 4 villages
were covered during the socio economic study of the project area.
Kutch
Kutch literally means something which intermittently becomes wet and dry; a large part of
this district is known as Rann of Kutchwhich is shallow wetland which submerges in water
during the rainy season and becomes dry during other seasons. The same word is also used
in the languages of Sanskrit origin for a tortoise. The Rann is famous for its marshy salt
flats which become snow white
after the shallow water dries up
each season before
the monsoon rains. Kutch District is
surrounded by the Gulf of
Kutch and the Arabian Sea in south
and west, while northern and
eastern parts are surrounded by
the Great and Little Rann (seasonal
wetlands) of Kutch. When there
were not many dams built on its rivers, the Rann of Kutch remained wetlands for a large
part of the year. Even today, the region remains wet for a significant part of year.1 In 2011,
Kachchh District had population of 2,092,371 of which male and female were 1,096,737
and 995,634 respectively. 2
Bhacahu
Bhachau is a Taluka in Kachchh District of Gujarat State, India. It is located 81 KM towards
East from District head quarters Bhuj. 275 KM from State capital Gandhinagar towards East.
Bhachau Taluka is bounded by by Gandhidham Taluka towards South , Adipur Taluka
towards west , Anjar Taluka towards west , Rapar Taluka towards North . Gandhidham City ,
1 http://en.wikipedia.org/wiki/Kutch_District
2 http://www.census2011.co.in/census/district/182-kachchh.html
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 208
5
Adipur City , Rapar City , Bhuj City are the nearby Cities to Bhachau. Gujarati is the Local
Language here. Also People Speaks Sindhi, And Hindi, Kutchi .3
Table: 1 Coverage Details
No. Name of the District Name of the Taluka
Name of the Village
1
Kutch Bhachau
Samakhiyali
2 Chhadavada
3 Vijpasar
Looking to the below table data shows that population is varies in each village form 800 to
10,500, approximately 500 to 200 HHs. Samakhiyali having more population compare to
other 2 villages. Looking to average country literacy rate 74.04% compare to this Chhadawad
and Vijpasar rate is very low
Table: 2 Basic information about villages
Name of the village Population Literacy level
Samakhiyali 10,402 73.24 %
Chhadawada 1,953 49.07 %
Vijpasar 876 56.25 % ReF: http://www.census2011.co.in/data/village
3 http://www.onefivenine.com/india/villag/Kachchh/Bhachau
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 209
6
2. Study Design
Pre designed and pre tested tools with multiple research methods like qualitative and quantitative
were utilized during the study to collect the
data from the various types of target groups.
Through focus groups discussion and individual
interviews socio economic status, culture,
practices, status of the education, occupation
scenario etc. information have been collected.
Al the data were analyzed through SPSS
(Statistical Package for Social Science).
Thorough village profile data was collected on
various indicators;
• Infrastructure availability
• Caste
• Occupation
• Heath and education services
• Financial institutions
• Social institutions
• Community infrastructure
• Sanitation and drinking water facility
Covered topics:
• Basic profile of village
• Health
• Education
• Livelihood
• Agriculture
• Animal Husbandry
• Women Empowerment
Types of Respondents:
• Community members
o Youth, Elder etc.
• Service Providers
o Teachers
o ASHA Workers
o Aganwadi Workers etc.
• PRI members
Various caste groups covered
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 210
7
3. Data Findings based on FGD and Village Profile
In this part of the report all the findings have been elaborated in detail, all this data gathered
from the community at grass root level.
Health
Health is a state of complete physical, mental and social well being, and not merely the
absence of disease or infirmity. During the discussion on this topic community shared many
things related to health, looking to these3 villages they are not in interior part of the rural area
so generally people are aware about the health care.
Table: 3 Availability of Health facilities
Name of the Villages
Health Centers
PHC Sub
Centre Private Clinics
Govt. Hospital
RMP Doctors
Traditional Healers
Home Remedies
Samakhiyali YES YES YES NA NA NA NA Chhadawada NA NA YES NA NA NA NA Vijpasr NA NA yes NA NA NA NA Source: Data based on data collection (NA-Not Available)
During the field visit we came to know that out of 3 villages, only 1 village having Public Health
center, rest of the villages do not have this facility. From all this villages community is going to
Samakhiyali for the treatment. Some of the special information mentioned below;
• In the some of the villages like Chhadavada, Vijpasar of Bhachau taluka do not have any
PHC or sub center in the village, so they are going to nearby village or taluka level for
the health treatment. Needs to provide tem some basic health facility on monthly or
weekly basis.
• Mainly in all the villages they are facing problem at the time of delivery, but 108 helping
a lot.
Education
Education means to discover new things which we don't know about and increase our
knowledge. An educated person can contribute to the society. From the interaction with the
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 211
8
community we came to know that education level in the village is comparatively good, means
more than 75% people are literate4. There are some education facilities which are listed below.
Table : 4 Availability of Education facilities
No Name of the
Villages
Education Facilities
Anganvadi Primary Upper
Primary High School Intermediary College
1 Samakhiyali YES YES YES NA NA NA
2 Chhadawada YES YES NA NA NA NA
4 Vijpasr YES YES YES NA NA NA Source: Secondary Data, data coolection
(NA-Not Available)
Aganwaid is basic amenities at village level, as per the Govt. rule almost each and every village
having Aganwadi, in this all three village having aganwadi which needs some beautification and
up gradation for better services.
Government is doing many efforts to promote primary education. In the village people mindset
have been changed compare to past, parents are taking interest in their children education. Table
4 shows available education facilities in the village.
• All three villages having primary school
• Two villages Samkhyali and Vijpasar having upper primary school.
• Students are going to Bhachau or Adipur for the higher studies.
• Limited teachers are the basic problem in all the schools
• Quality of infrastructure is also one of the weak point
• School Management Committee should be strengthen.
Livelihood
A “livelihood” is defined as one’s “means of support or subsistence” or the activities that
economically support a person and his/her family. We are focused on providing opportunities for
the working poor (in various occupations) to increase their income-generating capacity. In all
the villages community is associated with various occupations, the details mentioned below.
4 Based on census 2011 data
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 212
9
Table: 5 Occupation Details
No Name of the
Villages Agriculture Agriculture
Labor
Working as wage labor in other sectors
Private Job
1 Samakhiyali 60% 20% 15% 5%
2 Chhadawada 50% 20% 20% 10%
3 vijpasar 70% 20% 5% 5%
Source: secondary data, data collection
Data shows that majority of the population are associated with agriculture related activities. Out
of 12 months people are getting work more than 4 months in the agriculture.
The most important and good thing is there is no wage discrimination between male and female.
Rs. 150-200/day they are getting from the agriculture work, while in private sector they are
getting Rs. 250-300/day based on the skill of the worker.
Only one village is name of the lakhpat having good irrigation facility because of that people are
associated with the agriculture for the entire year.
Majority of the farmers (90%) are small farmers, rest of the big farmers having more than 5 acer
land.
Animal Husbandry
A large number of farmers in India depend on animal
husbandry for their livelihood. In addition to
supplying milk, meat, eggs, wool and hides, animals,
mainly bullocks, are the major source of power for both
farmers and dryers.
Almost 50% to 60% villagers are selling milk at the dairy in
the village. all three village having facility of pvt. Dairy, only
vijpasar don’t have any dairy.
Women Empowerment
Only Samakhiyali village having Self Help Groups and women are doing saving activities in the
groups but not associated with any type of income generation work.
Skill development, absence of advanced knowledge and information are the basic problems for
the women empowerment.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 213
10
Benefits of the government schemes
Government Schemes plays important roles in development of society. During interaction with
community and PRI members we came to know that, in most of the villages’ people received
benefits of Indira Awas, Sardar Awas, Chiranjivi Yojna. While there is very less awareness
about sanitation in all the villages, approx only 5 to 15% villagers having sanitation facility at
their home.
Infrastructure facilities
Infrastructure is the most important contributors to the economy of the State. Infrastructure is the
subset of the infrastructure sector and plays a significant role in generating revenue for the
economy. During the study we have received information about facilities available in the
villages, which are listed below.
Table: 6 Facilities available
No Name of the
Villages
Facilities
Road (Nos) Internal road
Electricity
in HHs
Public Transportation in a day (Nos)
Pucca Katcha Mud Bus Share Auto
Other
1 Samakhiyali 52 3 NA 100% 100 250 NA
2 Chhadawada 6 2 2 95% NA 20 NA
3 Vijpasar 1 2 3 90% 1 2 NA Source : Secondary data, data colleciton
(NA-Not Available)
Road facilities are most important in any village. While we talking about our study area, from
the table we can see that road facility is moderate in Samakhiyali,. In other 2 village
(Chhadawada,Vijpasr) it is very poor.
While we talking about electricity, it is the basic facility of any households. In our study area,
we can see good scenario in all the villages. Frequency of the public transport is also good in
all the study villages except Chhadavada and vijpasr
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 214
11
Table : 7 Common facilities
No Name of the
Villages
Facilities
PDS Panchayat/Sarpanch
Office Community
Hall SHG
Building TV
Room 1 Samakhiyali Available Available Available NA Available
2 Chhadavada Available Available NA NA NA
3 vijpasar Available Available NA NA NA
Source: Secondary data, data collection, (NA-Not Available)
While we talking about common facilities in the villages, it is quite moderate in all the villages
except Samakhiyali. Panchayt CEO is one of he good concept, under CSR activity it should be
covered so village community will able to get hand holding support for administration work.
Sanitation and Drinking water facilities
Sanitation generally refers to the provision of facilities and services for the safe disposal of
human urine and feces. Inadequate sanitation is a major cause of disease world-wide and
improving sanitation is known to have a significant beneficial impact on health both in
households and across communities. The word 'sanitation' also refers to the maintenance of
hygienic conditions, through services such as garbage collection and wastewater disposal.
During the study we have received some information about availability of Sanitation and
Drinking water facilities which are listed below.
Table: 8 Facilities of Sanitation and Drinking water
No Name of
the Villages
Facilities Sanitation Drinking Water
Individual HHs (%)
Common Toilets
School Toilets
Market Place
Overhead
tanks
Hand Pump
Street/Public taps
Individual
Connections
Undergroun
d tanks
Ponds
1 Samakhiy
ali
80% YES YES NA YES NA YES YES YES YES
2 Chhadaw
ada
15% NA YES NA YES NA YES YES YES YES
3 Vijpasr 20% NA YES NA NA NA NA YES YES NA Source: Secondary data, data collection
(NA-Not Available)
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 215
12
From the above mentioned data we can say that result about sanitation is very poor except
Samakhiyali village.
Government has launched the scheme for sanitation and gives subsidy for toilet construction, but
still they are not ready to build toilets at home.
Source of fuel
During the visit we came to know that level of fuel source is very low in the study villages. Very
few HHs has LPG connection in every village. They are still using wood for cooking.
Table: 9 Availability of fuel source
No Name of
the Villages
Sources Sources Fuel Wood
LPG (%)
Bio-gas Kerosene Solar
energy Natural Forest
Mangrove Forest
Tank bund
1 Samakhiy
ali
YES NA YES NA YES NA NA
2 Chhadaw
ada
YES
2%
NA YES NA YES NA NA
4 Vijpasr YES
3%
NA YES NA YES NA NA
Source: Secondary data, data collection
(NA-Not Available)
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 216
13
4. Data Findings based on individual interaction and FGD
with the community members
CSR Activities
Company has done CSR activities in VONDH village, in this village they have provided basic
sanitation facilities to the community during FGD and individual interaction we found that
Ronadh is not developed village only one aganwadi, one primary school and limited
infrastructure, literacy rate s also not match with avg, country rate. Youth needs more guidance
on future development
Name of village: Vondh Name of Tehsil: Bhachau
Name of visitor: Vipul Pandya Date:30/11/15
Name of Participants:
Sr.No. Name
1 Rakabhai Mistry
2 Manjibhai Bava
3 Rameshbhai Valmiki
4 Laxman Medaji Mistry
5 Shamji Someshbhai Sohil
6 Govindbhai Bava
7 Babubhai Mistry
8 Selabhai Sobhatbhai Vaniya
Under CSR company has provided 12 individual ,
earlier they were facing many problems , in winter or
in rainy season it was difficult to go out for sanitation
in open area.
Rameshbhai Valmiki
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 217
14
Name of village: Sadavada Name of Tehsil: Bhachau Name of jilla: Kutch
Name of visitor: Vipul Pandya Date:30/11/15
Name of Participants:
Sr.No. Name
1 Bavia Samaria Kohli
2 Ransod kana Donngar
3 Viram Amra Rabari
4 Maka Arjan Harijan
5 Govingbhai Panchabhai Rabari
Under CSR activities Company is giving facility to
provide fodder into Gaushala.
In Chadawad, company has built up
protection wall on pond in 2015 which helps
for water management and also adding some
infrastructure value.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 218
15
Needs to be focused for the development
• During the interaction with respondents research team has collected information about
the bottlenecks of the development and major issue which are impede into development
of the village.
Village Specific needs:
Table 13: Village wise requirements
Source: Secondary data, data collection
To know about the impact of the CSR activities and to know about community need FGD were
planned in all the villages. In this part of the report details have been mentioned.
Village: Chhadavada
Health: in this village health facility is not good, people are going to Bhachau for the treatment
which is 14 Kms far from the village because of the health seeking beahivour is very low in the
community.
Education-
Values (%) Respondents
Detail Samakhiyali Chhadavada
Vondh Vijpasr
Road 35.7 81.8 69.2 30.8
Drainage 14.3 18.2 30.8 30.8
Transportation 21.4 36.4 0 0
Loan 14.3 0 15.4 7.7
Government
Help
14.3 0 23.1 0
Toilets 14.3 45.5 30.8 30.8
Housing 7.1 9.1 23.1 38.5
Street Light 7.1 36.4 23.7 7.7
Employment 14.3 27.3 7.7 0
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 219
16
Only Primary school available in this village. 75% people are literate, female literacy level is
comparatively low in the community (30-40%).
Girls are not allowed for higher education, parents are not allow their girls to go outside of the
village, also they are having mentality that why should we invest money for girl education?
Livelihood
In the village majority of the population are associated with agriculture and animal husbandry.
20%people are going to saltpan; people do not have any skill to do other work. theyhave not
received much benefit from the company for the livelihood, only two people are getting job in
the company.
Agriculture
People are taking two corps in a year; main crops are Guvar, Bajara and castor. Main market is
Bhacahu. Land is very dry in the village which is the major problem.
Animal Husbandry
People are not happy with current dairy structure, they are not getting good price of the milk.
CSR activities
ET and Essar Company have provided some funds for the fodder of the Animals.
Village: VONDH
This is common for Scio ecomomic and impact of CSR activities. As per the study will cover all
the topics. In the cash of CSR impact theme wise before and after condition will be asked.
Health:
In the village Sub center is not available and PHC is far away 8km in bhachau. ANM is coming
near samakhyali village so people are going to nearby village or taluka(Bhachau) level for the
health Treatment. Delivery time women are going to Bhachau Private Hospitals.
Education
2 Primary schools available in this village. One is girls school (1 to 8 std.) and other Boys
School(1 to 8std ) and one highschool availebal in this villege.
Students are going to Samakhiyali or bhachau for the higher studies. Paretns are not sending their
girls for higher education because of transportation and also worried for their safety.
Livelihood
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 220
17
Only agriculture and animal husbandry are the major options in the village.
The most important and good things is there is no wage discrimination between male and female.
Rs 200- 250/day they are getting from the agriculture work. While in private sector they are
getting Rs 250 – 300/day based on the skill of the worker.
1 people are working with asr multiMetal Limited for draiving work
Animal Husbandry
Two Private dairies are available in this village. No any Government dairy available in this
village. Vondh village members are not happy with private dairy structure, They are not getting
satisfactory price.
Women empowerment
This village don’t have any Self Help Groups.
CSR Activity
• asr Company has approved 2.5 lakhs for the construction of toilet for fodder of the
individual, from which they have credited 2.5 lakhs in the year of 2015.
Village: vijpasar
Health
Any one heth survic are not available in this village but only ANM is vailabel for health
services, basic treatment is providing to women and children. Male members are going to
samakhyali or Bhachau.
Education
Only Primary school available in this village. 80% people are literate. 20% people are illiterate.
Girds education for higher study and for high school is one of the sensitive issue in the village,
parents are not allow their girls to go out of the village for the education, safety and financial
conditions are major problems behind that.
Livelihood:
Mainly community is associated with agriculture work, 60% of the members having their own
land and others are doing agriculture labour in the village. Because of good irrigation in the
village people are taking three crops in the year.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 221
18
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 222
Annexure 16: NABET certificateAnnexure 16: NABET certificateAnnexure 16: NABET certificateAnnexure 16: NABET certificate
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 223
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 224
Annexure 17: TOR copyAnnexure 17: TOR copyAnnexure 17: TOR copyAnnexure 17: TOR copy
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 225
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 226
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 227
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 228
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 229
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 230
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 231
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 232
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 233
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 234
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 235
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 236
5. Revised Corporate Environment Resposibility based on the issues emerged during PH
along with time bound action plan and budgetary provision as per revised CER norms.
6. Proof of application for drawl of groundwater
7. Revised Corporate Environment Policy inter alia including standard operating process
/ procedures to bring into focus any infringement / deviation / violation of the
environmental or forest norms / conditions; hierarchical system or Administrative order
of the company to deal with the environmental issues and for ensuring compliance with
the environmental clearance conditions; and system of reporting of non-compliances /
violations of environmental norms to the Board of Directors of the company and / or
shareholders or stakeholders at large.
31.17. Proposed expansion project by M/s ASR Multimetals Private Limited, located at
Village Chhadwada, Tehsil, Bhachau, District, Kutch, Gujarat [Online Proposal
No. IA/GJ/IND/27526/2015; MOEFCC File No. F. No. J-11011/251/2007-IA II (I)]
– Extension of validity of ToR.
1.0 M/s ASR Multimetals Private Limited made online application vide proposal no.
IA/GJ/IND/27526/2015 dated 5th April 2018 seeking extension of validity of terms of reference
issued vide F. No. J - 11011/251/2007 - IA II (I) dated 07.07.2015.
2.0 It was informed that the plant is operative from 2005. Initially company had installed
rolling mill products. The details of rolling mill products for existing plant are as mentioned
below:
Product Quantity Remarks
MS Rods 5000 MT/month EC was not applicable to
these products.
CCA was renewed vide order
no. AWH 55787 dated
25/07/2013 and valid up to
13.05.18
MS Wires 2500 MT/month
MS Flats 2500 MT/month
Re rolled steel products of MS i.e
channels, angles, bars, rounds,
sections and profiles etc
2000 MT/month
Steel billets/ ingots 12,333 MT/month
3.0 Company later applied for expansion project for sponge iron, pig iron and captive
power plant. The products were covered under EIA notification 2006 and accordingly EC was
applied to MoEF. EC was obtained for the same vide letter no. F. No. J- 11011/ 251/2007- IA
II (I) dated 31st March 2008 with validity of five years. Products considered for EC are:
Product Granted
capacity
Installed
capacity
Remark
Sponge iron 6000
MT/month
5500
MT/month
Company has obtained
consent to operate for sponge
iron plant and captive power
plant vide order no. AWH
55787 dated 25/07/2013 and
the plant has commissioned.
Captive power plant
• Coal/ lignite based CPP
• WHRB
20 MW
• 16 MW
• 4 MW
8 MW
• 4 MW
• 4 MW
Pig iron 5400
MT/month
--- Pig iron plant was not
installed and accordingly
Consent to operate was not
obtained.
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 237
4.0 Now the company proposes for expansion in their existing manufacturing capacity.
Company has procured additional land for the same. The Extended product profile is as
mentioned below:
Name of Products /By Products
& Intermediate Products
Existing quantity Proposed quantity
MT/month
Total quantity
MT/month
MS (MILD STEEL) Rods 5000 MT/Month 24000 MT/Month
36000
MT/Month MS (MILD STEEL) Wires 2500 MT/Month
MS (MILD STEEL) Flats 2500 MT/Month
Re-Rolled Steel Products of
MS (i.e. Channels, Angles
Bars, Rounds, Sections &
Profiles etc.)
2000 MT/Month
Steel Billets / Ingots (Semi
Finished Products)
12333 MT/Month 24000 MT/Month
(Along with
Preheater & LRF)
36333
MT/Month
Sponge Iron 5500 MT/Month 15000 MT/Month 20500
MT/Month
Power from AFBC Boiler
(Coal Base)
4 MW 17 MW 21 MW
Power from WHRB (Waste
Heat Gases from Rotary Kiln)
4 MW 8 MW 12 MW
5.0 Terms of reference was issued to the proposed project by MoEF vide letter no. J -
11011/251/2007 - IA II (I) dated 07.07.2015. Due to market viability the project was kept on
hold. As per the office memorandum vide letter no. J-11013/41/2006 IA.II(I) dated 29.08.2017,
ToR will get expire on 07.07.2018. Therefore, requested to extend the validity of ToR for one
more year to for preparation of EMP and PH.
6.0 After detailed deliberations the committee recommended for extension of validity of
ToR one more year i.e. up to 06.07.2019.
31.18. Expansion of Ferro Alloys plant at Manesamudram&Malguru Villages, Hindupur
Mandal, Ananthpur District, Andhra Pradesh by M/s M.B. Smelters Private
Limited [Online proposal No. IA/AP/IND/6013/2011; MoEFCC File No. J-
11011/647/2009-IA.II(I)] - Validity of extension & amendment to EC
Consideration of the proposal was deferred as the Project Proponent did not attend the meeting.
The proposal may be considered subject to satisfactory explanation of the reasons of absence
by the applicant
31.19. Enhancement of production (in pulp from 2,20,000 to 2,30,000 BDTPA and in paper &
paper board from 3,00,000 to 3,20,000 TPA) by de-bottlenecking of present equipment
& processes in existing pulp, paper and paper board and power plant at village Chandili,
District Rayagada, Odisha by M/s JK Papers Limited [Online Proposal No.
IA/OR/IND/3049/2011; MoEFCC File No. J-11011/172/2010-IA.II(I)] – Expansion
under clause 7(ii) of EIA Notification, 2006
1.0 M/s JK Papers Limited has made an application vide online proposal no.
IA/OR/IND/3049/2011 dated 8th March 2018 for Enhancement of production (in pulp from
ASR Multimetals Private Limited EIA FOR STEEL AND POWER PLANT
DETOX CORPORATION PVT LTD A - 238