5
elita CT-700 _ See complete EPA-certified test results at: www.alkaviva.com. • Chloramine • VOCs • THMs • Pesticides • Detergents • Pharmaceuticals • Agricultural Chemicals • Industrial Waste • Chlorine • Fluoride • Lead • Arsenic • Aluminum • Mercury • Chromium 6 • Pathogens Removes up to 99.9% of the following contaminants: inside AlkaViva’s proprietary patent- pending UltraWater filtration technology is included in the , providing peace of mind and the cleanest, healthiest water. Only from USER MANUAL

Upload: others

Post on 09-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: inside elita CT-700 - AlkaViva · elita CT-700 _ See complete EPA-certified test results at: . • Chloramine • VOCs • THMs • Pesticides • Detergents • Pharmaceuticals •

elitaCT-700

_

See complete EPA-certified test results at:www.alkaviva.com.

• Chloramine

• VOCs

• THMs

• Pesticides

• Detergents

• Pharmaceuticals

• Agricultural Chemicals

• Industrial Waste

• Chlorine

• Fluoride

• Lead

• Arsenic

• Aluminum

• Mercury

• Chromium 6

• Pathogens

Removes up to 99.9% of the

following contaminants:

insideAlkaViva’s proprietary patent-

pending UltraWater filtration

technology is included in the

, providing peace

of mind and the cleanest,

healthiest water.

Only from

USER MANUAL

Page 2: inside elita CT-700 - AlkaViva · elita CT-700 _ See complete EPA-certified test results at: . • Chloramine • VOCs • THMs • Pesticides • Detergents • Pharmaceuticals •

UltraWater cartridgehousing

Important Instructions

‧Never run hot water through your ionizer as this can damage your UltraWater Filter.

‧Wash with warm, soapy water and a soft cloth or sponge. Using harsh materials may result in scratches in the finish.

‧Protect your from freezing temperatures.

‧Install only on a hard and level surface. ‧Forcefully pushing in the diverter valve pull-out tab to return the flow of water to your faucet while your water is still running will damage the diverter valve. To turn off the flow of water from your , simply turn off the water at your tap.

‧Make sure to use your only with potable water which is suitable for human consumption.

‧For the best pH and ORP results, allow the filter to soak inside of the housing overnight activating the media inside. (The water is safe to drink immediately after flushing and will be clean and contaminant free, but will need to soak for optimal results.)

‧Do not close, bend, pinch, press or otherwise obstruct output port or hose.

‧If you plan on not using your for an extended period (more than 3 weeks) , remove the filter and store it in a plastic bag in your refrigerator.

‧Contact Technical Support at (775) 324-2400 Option 2 if repair is needed.

Congratulations

on Your New Purchase!

Page 3: inside elita CT-700 - AlkaViva · elita CT-700 _ See complete EPA-certified test results at: . • Chloramine • VOCs • THMs • Pesticides • Detergents • Pharmaceuticals •

The electronic filter monitor blinks and emits an audible sound notifying you that the filter has reached its capacity. Replace the filter immediately for the cleanest, healthiest water.

a. Once the diverter and the cold water line are attached, the is ready for use. Turn on the faucet, then pull the diverter knob toward you (Fig. 4) This diverter valve diverts the water from your tap to the unit where it flows through the UltraWater filter and out the faucet.

b. The first time you use your please flush the carbon from the filter for a minute or two – until the water is clear. This carbon flush is not harmful.

c. When in use, the filter monitor shows the remaining filter life on the LCD. The LCD automatically turns off to save battery power, 10 seconds after the water stops flowing.

Slide off the battery cover and put in 2 AAA batteries.Then slide back the batterycover and close. (Fig.1)

Place the water ionizer nearthe sink where the ionizerwill be installed.

1 2

4

5

3Remove the aerator from thefaucet

Remove the compression nutfrom the diverter valve andthread the plastic supplytubing through it, making sure to keep the threads of the compression nut facing the diverter valve.

Attach the plastic supplytubing to the diverter by pressing it onto the compres-sion nipple and securingthe compression nut to thediverter valve.

Attach the diverter valve tothe faucet using any includedadapter rings necessary. Besure to clean any exposedthreads and apply plumber’stape to prevent leaks. Ifinstalling to a pull-out/spraystlye faucet, please contactyour dealer for informationon a specialty adapter thatmay be required.

Attaching to Faucet

Page 4: inside elita CT-700 - AlkaViva · elita CT-700 _ See complete EPA-certified test results at: . • Chloramine • VOCs • THMs • Pesticides • Detergents • Pharmaceuticals •

Use the plastic wrench to twist the housing of the water filter counter-clockwise. Take out the old UltraWater cartridge, and replace with a new one. Then twist the housing of the water filter clockwise until snug. (Fig 5)

After the filter cartridge is replaced, press the reset button to reset the filter counter to zero. Should you choose to reset the filter counter before it reaches capacity, Press the Reset button while holding down the Display button (then let go of the buttons). The LCD monitor will begin blinking indicating it is resetting the counter. It will stop blinking within 10 seconds once it resets to zero.

When the battery power is low, the electronic filter monitor will generate an audible sound and you will see a blinking battery symbol in the upper right corner of the LCD display indicating a battery replacement is needed. Once you have replaced the batteries, this alert will stop.

The LCDuses two AAA alkaline batteries that last approximately one year. Should the batteries fail before you replace them, the last data recorded will automatically be saved.

Replacing Your UltraWater Filter

Reset the Counter

Low Battery Power Alert

Saves YourUsage Data

If you have never consumed alkaline water, let your body adjust slowly and naturally for 4 to 7 days. This can be accomplished by introducing the alkaline water by alternating 1/2 UltraWater and 1/2 the other water that you normally drink.

As your body naturally adjusts, you can begin to introduce 100% alkaline water into your daily regimen. (If you are taking time-released medication, it is recommended that you take it with filtered water since medications are absorbed more quickly with alkaline water.)

Getting Started Drinking Alkaline Water

Warranty / Return Policy

If at any time in the first 14 days you wish to return your non-electric ionizer, we will give you a full refund, less 20% restocking fee, as long as your non-electric ionizer is returned in‘as new’condition and in its original packing. The warranty is for 3 years and begins on the original purchase date. The warranty covers all parts and 100% of labor costs due to manufacturing defects only. Customer is responsible for shipping costs both ways unless the unit is defective out of the box. The warranty expressly excludes damage caused by environmental damage, including but not limited to mineral buildup due to hardwater, or high levels of iron, or poor source water quality. For complete warranty information see www.alkaviva.com/alkaviva-return-policy.aspx