Leader inLevel Measurement
For Assistance Call 1-800-527-6297Outside North America 1-215-674-1234
Installation andOperating Instructions
((215) 674-1234 Drexelbrook Headquarters1-800-527-6297 Service Assistancehttp://www.drexelbrook.come-mail:[email protected]
Series 506-6000 LCS™Point Level Control
using 406-6000, 406-6100, or406-6300 Electronics
AMETEK Drexelbrook makes no warranty of any kind with regard to the material containedin this manual, including, but not limited to, implied warranties or fitness for a particularpurpose. Drexelbrook shall not be liable for errors contained herein or for incidental orconsequential damages in connection with the performance or use of material.
Copyright 2001 AMETEK Drexelbrook
Series 506-6000 LCS™Point Level Control
using 406-6000, 406-6100, or406-6300 Electronics
EDO #6-02-241506-6000-LM
205 Keith Valley Road Horsham, PA 19044US Sales 800-553-9092 24 Hour Service 800-527-6297International 215-674-1234Fax 215-674-2731E-mail [email protected] www.drexelbrook.comAn ISO 9001 Certified Company
DREXELBROOK
EDO # 6-02-241 506-6000-LM
Table of Contents1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
Introduction ............................................................................................. 31.1 System Description ....................................................................... 31.2 Models Available .......................................................................... 4
Specifications ............................................................................................ 62.1 Electronic Unit ............................................................................... 62.3 Connecting Cables ....................................................................... 62.3 Sensing Elements ......................................................................... 7
Theory of Operation .................................................................................. 83.1 Electronic Unit ............................................................................... 83.2 Sensing Element .......................................................................... 93.3 Connecting Cables ....................................................................... 9
Installation4.1 Unpacking ...................................................................................... 104.2 Mounting the Electronic Unit ........................................................ 104.3 Mounting the Sensing Element ................................................... 104.4 Wiring the Electronic Unit ............................................................ 114.5 Wiring the Sensing Element ........................................................ 124.6 Installation of Flush-Mounted Sensing Elements ..................... 13
Calibration .............................................................................................. 145.1 Start-Up ........................................................................................... 145.2 Controls ........................................................................................... 145.3 Calibration Procedures ................................................................. 15
Troubleshooting ......................................................................................... 206.1 Introduction .................................................................................... 206.2 Electronic Unit Checkout ............................................................. 206.3 Relay Circuit Checkout ................................................................ 206.4 Sensing Element Checkout ........................................................ 2 16.5 Cable Checkout ............................................................................ 226.6 Problems and Causes ................................................................. 23
Factory and Field Service Assistance .................................................... 247.1 Telephone Assistance.. ................................................................ 247.2 Equipment Return ......................................................................... 247.3 Field Service .................................................................................. 247.4 Customer Training ......................................................................... 24
Appendix A ............................................................................................. 25 406-6300 Supply Voltage Conversion (240/120 Vac) ......................... 25
Appendix B ............................................................................................. 26Shortening or Lengthening the Sensing Element ................................ 26
FM Installation Drawing ...................................................................................... 27
............................................................................................. 10
506-6000-LM/p2