installation and service instructions stopper station ...of arrow (clockwise) until button pops up....

8
Installation and Service Instructions Stopper ® Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9 Switch Rating 2 Form C Contacts LED Power 125/250 VAC, 10A, ½ HP 12-24 VAC/VDC, 21 mA 30 VDC, 6A (Power Supply Not Included) ADA Compliant We protect the things that protect you. ® NOTE For LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A, the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A maximum rating 30 VDC 3A. For access control installations, power for the LT-1 Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. REMARQUE Pour les modèles LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A est de 30 VCC 3A. Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1 doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. UL294 Performance Levels: LTUL Models Line Security: I Form “C” Contacts on Timer Attack: I Rated 30 VDC 3A Endurance: IV Standby Power: I

Upload: others

Post on 01-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

Installation and Service Instructions Stopper® Station Series Push Button

Models SS2xx2, SS2xx5, SS2xx9

Switch Rating 2 Form C Contacts LED Power125/250 VAC, 10A, ½ HP 12-24 VAC/VDC, 21 mA30 VDC, 6A (Power Supply Not Included)

ADACompliant

ADACompliant

We protect the things that protect you.®

NOTE For LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A, the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A maximum rating 30 VDC 3A. For access control installations, power for the LT-1 Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used.

REMARQUE Pour les modèles LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles LTUL Models, Form “C” contacts on timer, Rated 30 VDC 3A est de 30 VCC 3A. Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1 doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés.

UL294 Performance Levels: LTUL Models Line Security: I Form “C” Contacts on TimerAttack: I Rated 30 VDC 3AEndurance: IVStandby Power: I

Page 2: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 2 -

Wire Connections

CONTACTSET 1

CONTACTSET 2

CONTACT BOX CONTAINSTWO CONTACT SWITCHES

NC

NO

NC

NO

COM

COM

WIRE CONNECTIONS

NO NC

COM

9 in. QUICK CONNECT WIRE LEAD(6) PROVIDEDMAKE SURE LEAD IS

FULLY CONNECTED TOMOUNTING TAB

ASSUREZ-VOUS QUELE FIL EST ENTIÈREMENTCONNECTÉ À LA PATTEDE MONTAGE

Housing Installation

BUTTON AND SWITCH ASSEMBLY

SWITCH HOUSING

ALLEN HEAD SCREW#8-32 x 3/8 in.

(1) PROVIDED

REMOVE SCREW. PULL BOTTOM OF HOUSING OUT AND LIFT UP UNTILTABS ARE RELEASED FROM SLOTS IN TOP OF SWITCH ASSEMBLY.

3/32” HEX WRENCH(1) PROVIDED

Procedure1. Pull bottom of housing out and lift up until tabs are released from slots

in top of switch assembly.2. Once complete, secure cover with screw and hex wrench (shown).

Page 3: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 3 -

Product Dimensions

1.62 in.(41mm)

1.58 in.(40mm)

MODELS WITHOPTIONAL BACK BOX

MODELSWITHOUT BACK BOX

PNEUMATIC

1.62 in.(41mm)

1 in.(25mm)

3.22 in.(82mm)

4.86 in.(123mm)

1.62 in.(41mm)

1.37 in.(35mm)

COM

NO

NC

MODELSWITHOUT BACK BOX

3.22 in.(82mm)

4.86 in.(123mm)

Installation

BUTTON ILLUMINATION WIRING12-24 VAC/VDC, 21mA EACH COLORBLACK - GROUNDWHITE - WHITE LED (+)GREEN - GREEN LED (+)RED - RED LED (+)

WHITE

BLACK

GREENRED

INSULATINGBUSHING

SCREW #6-32 x 1 in.(2) PROVIDED

BUTTON CAP(PUSH SHOWN)

SCREW#6 x 1-1/4 in.(4) PROVIDED

BUTTON AND SWITCH ASSEMBLY

ANCHOR(4) PROVIDED

DRILL (4)3/16 in. DIA. HOLES

OPTIONAL SURFACEMOUNT BACK BOX

NOTEADA MOUNTING COMPLIANCE REQUIRESTHE OPERABLE PART OF THE INTITIATING DEVICESHALL NOT BE LESS THAN 1.1m (3 1/2 ft.) ORGREATER THAN 1.37m (4 1/2 ft.) ABOVE FINISHED FLOOR SERVICE.

DRILL POINT LOCATION PROVIDED TOP AND BOTTOMFOR 1/2” CONDUIT FITTINGS. DRILL AS NEEDED.

BUTTON ILLUMINATION*ASSEMBLY

BUTTON CAPALIGNMENT HOLE

BUTTON ILLUMINATION WIRES*

NOTEADA MOUNTING COMPLIANCE REQUIRES THE OPERABLE PART OF THE INITIATING DEVICE SHALL NOT BE LESS THAN 1.1 m (3 ½ ft.) OR GREATER THAN 1.37m (4 ½ ft.) ABOVE FINISHED FLOOR SURFACE.

*

Page 4: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 4 -

On Site Button Reconfiguration Stopper Station button is configured as ordered. If needed, installer can reconfigure function to: Key-to-Reset, Momentary or Turn-to-Reset.

Changing Push Button Function

1. Remove contact block screws from mounting plate.

2. To change button function remove the plate and use directions provided.

3. Reassemble backplate and contact box (ensure contact tabs are facing up as shown).

4. If reconfiguring from Turn-to-Reset, remove Turn-to-Reset label.

Note: If you remove stop pin and wedge block, consider keeping for potential future use.

REMOVE SCREWS,MOUNTING PLATEAND SWITCH ASSEMBLY

MOUNTING PLATE

SWITCH ASSEMBLY

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

WEDGE BLOCK

STOP PIN

RESET RING

WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

WEDGE BLOCK

CAUTIONDO NOTREMOVE

CAUTIONDO NOTREMOVE

CONTACT TABS

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK(INCLUDED BUT NOT REQUIRED FOR MOMENTARY FUNCTION)

CAUTIONDO NOTREMOVE

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET(INCLUDED WITH CP-SS43 KIT)

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

R03424 WEDGE BLOCK(NOT USED FORTURN-TO-RESET)

CAUTIONDO NOTREMOVE

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

Page 5: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 5 -

Button Function Momentary

Procedure

1. Rotate reset ring counterclockwise as shown above.

2. Place stop pin in position shown.

3. If converting from Key-to-Reset, disregard key.

REMOVE SCREWS,MOUNTING PLATEAND SWITCH ASSEMBLY

MOUNTING PLATE

SWITCH ASSEMBLY

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

WEDGE BLOCK

STOP PIN

RESET RING

WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

WEDGE BLOCK

CAUTIONDO NOTREMOVE

CAUTIONDO NOTREMOVE

CONTACT TABS

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK(INCLUDED BUT NOT REQUIRED FOR MOMENTARY FUNCTION)

CAUTIONDO NOTREMOVE

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET(INCLUDED WITH CP-SS43 KIT)

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

R03424 WEDGE BLOCK(NOT USED FORTURN-TO-RESET)

CAUTIONDO NOTREMOVE

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

Page 6: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 6 -

Button Function Set-up – Key-To-Reset

KEY-TO-RESET SLOTLOCATED UNDER BUTTON

KIT-H18061 RESET KEY(2) PROVIDEDWHEN ORIGINALCONFIGURATION ISKEY-TO-RESET(INCLUDED WITH CP-SS43 KIT)

Procedure

1. Remove stop pin from position shown.

2. Once pin is removed, reset ring will rotate clockwise as shown above.

3. Replace stop pin in right hole.

4. Call STI for wedge block if original configuration is Turn-to-Reset.

5. If converting from Turn-to-Reset or momentary, call STI for key (KIT-H18061).

REMOVE SCREWS,MOUNTING PLATEAND SWITCH ASSEMBLY

MOUNTING PLATE

SWITCH ASSEMBLY

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

WEDGE BLOCK

STOP PIN

RESET RING

WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

WEDGE BLOCK

CAUTIONDO NOTREMOVE

CAUTIONDO NOTREMOVE

CONTACT TABS

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK(INCLUDED BUT NOT REQUIRED FOR MOMENTARY FUNCTION)

CAUTIONDO NOTREMOVE

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET(INCLUDED WITH CP-SS43 KIT)

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

R03424 WEDGE BLOCK(NOT USED FORTURN-TO-RESET)

CAUTIONDO NOTREMOVE

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

Page 7: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

- 7 -

TO RESET, TURNBUTTON IN DIRECTIONOF ARROW (CLOCKWISE)UNTIL BUTTON POPS UP.

L16210 RESET LABEL(INCLUDED WITHCP-SS43 KIT)

Button Function Set-up – Turn-To-Reset

Procedure

1. Remove wedge block.

2. Remove stop pin from right hole.

3. Reset ring will rotate clockwise as shown.

4. Place stop pin in left hole.

5. If converting from either momentary or Key-to-Reset, call STI for reset label (L16210).

REMOVE SCREWS,MOUNTING PLATEAND SWITCH ASSEMBLY

MOUNTING PLATE

SWITCH ASSEMBLY

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

WEDGE BLOCK

STOP PIN

RESET RING

WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

WEDGE BLOCK

CAUTIONDO NOTREMOVE

CAUTIONDO NOTREMOVE

CONTACT TABS

ROTATE RESET RING IN DIRECTION OF ARROWAND PLACE STOP PIN IN POSITION SHOWN.WEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK(INCLUDED BUT NOT REQUIRED FOR MOMENTARY FUNCTION)

CAUTIONDO NOTREMOVE

PLACE STOP PIN IN POSITION SHOWNWEDGE BLOCK MUST BE IN PLACE.

STOP PIN

RESET RING

R03424 WEDGE BLOCK –MUST PURCHASE IFORIGINAL CONFIGURATIONIS TURN-TO-RESET(INCLUDED WITH CP-SS43 KIT)

CAUTIONDO NOTREMOVE

REMOVE WEDGE BLOCK AND PLACESTOP PIN IN POSITION SHOWN

STOP PIN

RESET RING

R03424 WEDGE BLOCK(NOT USED FORTURN-TO-RESET)

CAUTIONDO NOTREMOVE

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

ATTENTIONNE PAS ENLEVER

Page 8: Installation and Service Instructions Stopper Station ...OF ARROW (CLOCKWISE) UNTIL BUTTON POPS UP. L16210 RESET LABEL (INCLUDED WITH CP-SS43 KIT) Button Function Set-up – Turn-To-Reset

SSREVC_IS, OCT2018Printed in USA

Safety Notice to Installers and UsersThis push button has been tested according to UL2017. It is important to read, understand and follow all instructions provided with this product. Non-fire alarm initiating devices are listed in UL category UEHX. It is the installer’s responsibility to comply with NEC and Canadian electrical code, mounting specifications according to ADA and other applicable fire and electrical codes. To avoid electrical shock , DO NOT attempt to install this product when power is on. To avoid possible confusion with fire alarm initiating devices, do not mount a red stopper station near a manual fire alarm initiating device. ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above finished floor service. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and maintenance of this product. Push buttons for outdoor use must be mounted with STI outdoor rated covers.

Remarques sur l’installation: Ce bouton-poussoir a été testé selon UL2017. Il est important de lire, de comprendre et de suivre toutes les instructions fournies avec ce produit. Les dispositifs de déclenchement d’alertes non incendie sont répertoriés sous la catégorie UL UEHX. Il incombe à l’installateur de se conformer aux normes NEC et Code canadien de l’électricité, aux spécifications de montage selon l’ADA et aux autres codes de prévention des incendies et de l’électricité en vigueur. Pour éviter un choc électrique, NE tentez PAS d’installer ce produit lorsqu’il est sous tension. Pour éviter toute confusion possible avec les dispositifs de déclenchement d’alertes d’incendie, n’installez pas un avertisseur Stopper rouge à proximité d’un dispositif de déclenchement d’alarme d’in cendie manuel. La conformité aux règles d’installation de l’ADA exige que la partie utilisable du dispositif de déclenchement soit installée à une hauteur située entre 1,1 m (3 1/2 pi) et 1,37 m (4 1/2 pi) au-dessus du plancher fini. Une fois l’installation et les essais terminés, vous devez fournir une copie de ce manuel à l’ensemble du personnel chargé de l’essai et de l’entretien de ce produit. Les boutons poussoirs pour utilisation à l’extérieur doivent être installés avec couvercles pour l’extérieur de STI.

2306 Airport Rd • Waterford, MI 48327, USAPhone: 248-673-9898 • Fax: 248-673-1246

[email protected] • www.sti-usa.com

Taylor House • 34 Sherwood Road • BromsgroveWorcestershire • B60 3DR • England • Tel: +44 (0)1527 520 999

Fax: +44 (0)1527 501 999 • [email protected] • www.sti-emea.com

WarrantyThree year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14.

WARNING: This product can expose you to chemicals including Dichloromethane, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm.For more information go to www.P65Warnings.ca.gov.