Page 1: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

DEVIreg™ 534Electronic Thermostat

Installation Guide

www.DEVI.com

Page 2: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it
Page 3: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

Table of Contents

1 Introduction . . . . . . . . . . . . . . . 31.1 Technical Specifications . . . . . 41.2 Safety Instructions . . . . . . . . 6

2 Mounting Instructions . . . . . . . . . 6

3 Settings . . . . . . . . . . . . . . . . . 9

4 Warranty . . . . . . . . . . . . . . . . . 14

5 Disposal Instruction . . . . . . . . . . 14

1 Introduction

DEVIreg™ 534 is an electronic timer temperature controller,specially designed for floor heating systems. The thermo-stat is provided with a combination of a floor sensor and aroom sensor to measure and control the desired floor androom temperature. It can be either flush-mounted or sur-face-mounted.

Once set, the thermostat will automatically adjust the heatto meet your comfort requirements by measuring the floortemperature and combining it with the measured air tem-perature regardless of changing weather conditions.

DEVIreg™ 534

Installation Guide 3

Page 4: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

The thermostat has buttons for adjusting the temperaturesetting, and a LED indicator showing standby periods(green light) and heating periods (red light).

More information on this product can also be found at:devireg.devi.com

1.1 Technical Specifications

Operation voltage 220-240V~, 50Hz

Standby power consump-tion

Max 0.30W

Relay:Resistive loadInductive load

Max 15A / 3450W @ 230Vcos φ= 0.3 max 1A

Sensing units NTC 15kOhm at 25°C

Sensing values:0°C25°C50°C

42kOhm15kOhm6kOhm

Hysteresis ± 0.4°C with floor sensoronly

Ambient temperature -10°C to +30°C

Frost protection tempera-ture

5°C -

DEVIreg™ 534

4 Installation Guide

Page 5: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

Temperature range 15-32°C with floor sensoronly

Cable specification max 1x4mm2 or 2x2,5mm2

Ball pressure temperature 75°C

Pollution degree 2 (domestic use)

Type 1C

Storage temperature -20°C to +65°C

IP class 31

Protection class Class II -

Dimensions 85 x 85 x 54mm (in-walldepth: 24mm)

Weight 107g

The product complies with the EN/IEC Standard "Automaticelectrical controls for household and similar use":

▪ EN/IEC 60730-1 (general)▪ EN/IEC 60730-2-7 (timer)▪ EN/IEC 60730-2-9 (thermostat)

DEVIreg™ 534

Installation Guide 5

Page 6: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

1.2 Safety Instructions

Make sure the mains supply to the thermostat is turned offbefore installation.

Please also note the following:

▪ The installation of the thermostat must be done by anauthorized and qualified installer according to localregulations.

▪ The thermostat must be connected to a power supplyvia an all-pole disconnection switch.

▪ The sensor is to be considered as live voltage. Havethis in mind if the sensor must be extended.

▪ Always connect the thermostat to continuous powersupply.

▪ Do not expose the thermostat to moisture, water, dust,and excessive heat.

2 Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable heighton the wall (typically 80-170cm.).

DEVIreg™ 534

6 Installation Guide

Page 7: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

The thermostat should not be placed inwet rooms. Place it in an adjacent room.Always place the thermostat according toNFC15100 - part 7-701.

Do not place the thermostat in a way thatit will be exposed to direct sunlight.

Note: A floor sensor enables a more accu-rate temperature control and is recom-mended in all floor heating applicationsand mandatory under wooden floors toreduce the risk of over-heating the floor.

▪ Place the floor sensor in a conduit in an appropriateplace where it is not exposed to sunlight or draft fromdoor openings.

▪ Equally distant and >2cm from two heating cables.▪ The conduit should be flush with the floor surface -

countersink the conduit if necessary.▪ Route the conduit to the connection box.▪ The bending radius of the conduit must be min 50mm.

DEVIreg™ 534

Installation Guide 7

Page 8: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

Follow the steps below to mount the thermostat:

1. Open the thermostat:

devireg™550 devireg™550

▪ Gently press the release tab in the bottom of thethermostat by a flat object.

▪ Carefully pull off the front cover.

2. Connect the thermostat according to the connectiondiagram.

IP31

-10T30

D534

Mains

220-240V~

Max. Load

15 (1) A Se

nso

r

N L NTCNLOAD

LLOAD

Standby maximum 0.3W

DEVIreg™ 534

8 Installation Guide

Page 9: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

The screen of the heating cable must be connected tothe earth conductor of the power supply cable by us-ing a separate connector.

Note: Always install the floor sensor in a conduit in thefloor.

3. Mount and reassemble the thermostat.

▪ Fasten the thermostat to a socket or an exterior wallbox by driving the screws through the holes in eachside of the thermostat.

▪ Tighten the screws to fasten the thermostat.

4. Turn on the power supply.

Initially main supply the thermostat for 15 hours to fullycharge the battery. The current time and day is then keptfor 80 days if mains supply is off. All other settings are stor-ed permanently.

3 Settings

Sensor: How to specify whether an external floor sen-sor, the built-in room sensor or both is used to controlthe floor heatingNote: The floor sensor option is selected by default.

DEVIreg™ 534

Installation Guide 9

Page 10: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

1. Press the installation button D with a blade end.

devireg™550 devireg™550

D

2. Press the • button.

3. Select one of the following options using the ▲▼buttons:

If only a floor sensor is used, choose:The built-in room sensor is not used.This option is suitable for rooms inwhich a constant floor temperature isrequired, e.g. in a bathroom.

If both a room sensor and a floor sen-sor is used, choose:This option is suitable for all roomsbut wet rooms. The thermostat mustbe installed in the same room as thefloor sensor and the heating elements.

DEVIreg™ 534

10 Installation Guide

Page 11: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

If only a room sensor is used, choose .This option is not recommendabledue to an increased risk of overheat-ing the floor. The thermostat must beinstalled in the same room as theheating elements.

4. To accept the new selected sensor mode, press •.

5. Press installation button D to configure settings.

6. If you have chosen the floor sensor or room/floor sen-sor option, press ▲▼ (up/down) buttons to continueto the next setting.

How to set the maximum floor temperatureSpecial condition: This setting only applies if a floor sensoris used (the floor sensor or room/floor sensor option hasbeen set).Note: The maximum floor temperature is set to 28°C bydefault.

1. To change the default temperature setting - press the• button.

2. Select the new temperature by using the ▲▼ but-tons.

3. To accept the new selected temperature, press •.

DEVIreg™ 534

Installation Guide 11

Page 12: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

4. Press installation button D to configure settings.

devireg™550 devireg™550

D

5. Press ▲▼ (up/down) buttons to continue the nextsetting.

Note: Please contact the floor supplier before changing themaximum floor temperature and be aware of the following:

▪ The floor temperature is measured where the sensor isplaced.

▪ The temperature of the bottom of a wooden floor canbe up to 10 degrees higher than the top.

▪ Floor manufactures often specify the max temperatureon the top surface of the floor (usually 27-28˚C).

▪ Always use a floor sensor or a room + floor sensorcombination to control floor heating. Without a floorsensor, the temperature control may be less accurateand you risk overheating the floor.

DEVIreg™ 534

12 Installation Guide

Page 13: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

Thermalresist-ance[m2K/W]

Examples of floor-ing

Details Approximatesetting for25˚C floortemperature

0.05 8 mm HDF basedlaminate

> 800 kg/m3 28˚C

0.10 14 mm beech par-quet

650 - 800kg/m3

31˚C

0.13 22 mm solid oakplank

> 800 kg/m3 32˚C

< 0.17 Max. carpet thick-ness suitable forfloor heating

acc. to EN1307

34˚C

0.18 22 mm solid firplanks

450 - 650kg/m3

35°C

How to define the temperature scale

You can select the display type. The choice is either numeri-cal scale 1-6 or Celsius scale 15° to 28°. Default is Celsiusscale. When selecting Celsius, the display will show the ac-tual temperature at the floor sensor.1. To change the default temperature scale, press the •

button.

2. Select a scale, use the ▲▼ buttons.

3. To accept the selected temperature scale, press •.

DEVIreg™ 534

Installation Guide 13

Page 14: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

4. If desired, go back or forward through your installa-tion settings by pressing the ▲▼ (up/down) buttons.

5. Press installation button D to exit the installationmode.

6. Put the frame and front back on.

4 Warranty

2Y E A R

5 Disposal Instruction

DEVIreg™ 534

14 Installation Guide

Page 15: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

DEVIreg™ 534

Danfoss A/SElectric Heating SystemsUlvehavevej 617100 VejleDenmarkPhone: +45 7488 8500Fax: +45 7488 8501E-mail: [email protected]

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter itsproducts without notice. This also applies to products already on order provided that such alterations can be made without subsequential changesbeing necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logo-type are trademarks of Danfoss A/S. All rights reserved.

0809XXXX & VIGDS102 Produced by Danfoss © 05/2012

Page 16: Installation Guide DEVIreg™ 534 - Danfoss Heatingheating.danfoss.com/PCMPDF/DEVIreg534_X012205_VIGDS102.pdf · NFC15100 - part 7-701. Do not place the thermostat in a way that it

D53

4 D

elea

ge

1911

6611

Ther

mos

tat

Room

Sen

sor

Prod

uct D

ocum

enta

tion

Des

igne

d in

Den

mar

k fo

r Dan

foss

A/S

57

03

46

61

85

77

3