Installation Instructions Iconic™ Series PIR Motion Sensor Mechanism 41EPIRM-TN DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH It is illegal for persons other than an appropriately licensed electrical contractors or other persons authorised by legislation to work on the fixed wiring of any electrical installation. To comply with all safety standards, the product must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed. There are no user serviceable parts inside the product. Failure to follow these instructions will result in death or serious injury. DANGER RISK OF ELECTRIC SHOCK Hazardous voltage and electrical current may be present at the wire leads of this product even when the device is switched off. Lock out and tag the input circuit before accessing the wiring connections. A circuit breaker (250 V a.c. 10 A) Type C must be installed according to AS/NZS 60898. Use a terminal block to connect the PIR Mechanism to the electrical circuit. After wiring, wrap the terminal block with insulating tape. Failure to follow these instructions will result in death or serious injury. CAUTION EQUIPMENT DAMAGE HAZARD Install the device according to instructions in this document. Pay attention to the specifications and wiring diagrams related to the installation. Do not use this product for any other purpose than specified in this instruction. Failure to follow these instructions can result in minor injuries, or equipment damage. NOTICE RISK OF EQUIPMENT DAMAGE OR MALFUNCTION (WIRING CONNECTIONS) To avoid damaging the equipment and possibly voiding the warranty: Test operation during installation and correct any wiring errors immediately. Keep cable insulation away from the sides of the enclosure to avoid possible damage or long term degradation of the cable insulation. Failure to follow these instructions can result in equipment damage or malfunction. Installation example: hallway A 1× sensor to cover hallway front entrance. B 1× sensor to cover hallway back entrance. C Zone mask used to prevent detection near the pet door. D Sensor covering lounge area. Zone mask used to prevent detection in the hallway zone. (See Zone masking.) PET DOOR PET DOOR HALL LOUNGE ZONE MASK SEGMENTS ZONE MASK SEGMENTS A B D C Detection pattern and range 100° Horizontal Max. 5 m @ 20–25 °C 82° Vertical Sensor locations Orientation for multi-gang installation Vertical Grid Horizontal Grid 4 1 E P IR M 3 5 2 M P I R 4 1 E P I R M 3 5 2 M P I R Fitting the PIR mechanism to the grid 1 Open the locking bar A. 2 Push the head of the PIR mechanism into the grid aperture until the head clicks into place B. 3 Close the locking bar C. A B C Cabling and connections Single PIR mechanism N A N L A N L L A N PIR MECHANISM LOAD PE PE A Active N Neutral L Load PE Protective Earth 2× PIR mechanisms (e.g. hallway application) N A PE L N A N L A N L L L A A N N PIR MECHANISM PIR MECHANISM PE LOAD A Active N Neutral L Load PE Protective Earth Securing the PIR mechanism fly leads Note: Ensure that the PIR mechanism fly leads are tied back or otherwise secured in accordance with the wiring rules and regulations that apply in the location where the mechanism is installed. Mounting the grid Wall box depth: min. 41 mm

Upload: others

Post on 30-Dec-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation Instructions - F2842 - 41EPIRM Iconic Series

InstallationInstructions

Iconic™ Series PIR Motion Sensor

Mechanism

41EPIRM-TN

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• It is illegal for persons other than an appropriately

licensed electrical contractors or other persons authorised by legislation to work on the fixed wiring of any electrical installation.

• To comply with all safety standards, the product must be used only for the purpose described in this instruction and must be installed in accordance with the wiring rules and regulation in the location where it is installed.

• There are no user serviceable parts inside the product.Failure to follow these instructions will result in death or serious injury.

DANGERRISK OF ELECTRIC SHOCK• Hazardous voltage and electrical current may be present

at the wire leads of this product even when the device is switched off.

• Lock out and tag the input circuit before accessing the wiring connections.

• A circuit breaker (250 V a.c. 10 A) Type C must be installed according to AS/NZS 60898.

• Use a terminal block to connect the PIR Mechanism to the electrical circuit.

• After wiring, wrap the terminal block with insulating tape.Failure to follow these instructions will result in death or serious injury.

CAUTIONEQUIPMENT DAMAGE HAZARD• Install the device according to instructions in this

document.• Pay attention to the specifications and wiring diagrams

related to the installation.• Do not use this product for any other purpose than

specified in this instruction.Failure to follow these instructions can result in minor injuries, or equipment damage.

NOTICERISK OF EQUIPMENT DAMAGE OR MALFUNCTION (WIRING CONNECTIONS)To avoid damaging the equipment and possibly voiding the warranty:• Test operation during installation and correct any wiring

errors immediately.• Keep cable insulation away from the sides of the

enclosure to avoid possible damage or long term degradation of the cable insulation.

Failure to follow these instructions can result in equipment damage or malfunction.

Installation example: hallway

A 1× sensor to cover hallway front entrance.B 1× sensor to cover hallway back entrance.C Zone mask used to prevent detection near the pet door.D Sensor covering lounge area. Zone mask used to prevent

detection in the hallway zone. (See Zone masking.)

PETDOOR

PETDOOR

HALLLOUNGE

ZONEMASK

SEGMENTS

ZONEMASK

SEGMENTS

A

B

D

C

Detection pattern and range

100° Horizontal

Max. 5 m @ 20–25 °C

82° Vertical

Sensor locations

Orientation for multi-gang installation

Vertical Grid Horizontal Grid

41EP

IRM

352

MPIR

41E

PIRM

352

MPIR

Fitting the PIR mechanism to the grid

1 Open the locking bar A.2 Push the head of the PIR mechanism into the grid aperture

until the head clicks into place B.3 Close the locking bar C.

A B C

Cabling and connections

Single PIR mechanism

NAN L

A

N

L

L

A

NPIR MECHANISM

LOAD

PE

PE

A ActiveN NeutralL LoadPE Protective Earth

2× PIR mechanisms (e.g. hallway application)

NAPE

L N

A

N

L

A

N

L

L L

AA

NNPIR MECHANISM PIR MECHANISM

PE

LOAD

A ActiveN NeutralL LoadPE Protective Earth

Securing the PIR mechanism fly leads

Note: Ensure that the PIR mechanism fly leads are tied back or otherwise secured in accordance with the wiring rules and regulations that apply in the location where the mechanism is installed.

Mounting the grid

Wall box depth:min. 41 mm

Page 2: Installation Instructions - F2842 - 41EPIRM Iconic Series

F2842 October 2017

Schneider Electric reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein.© Schneider Electric 2017This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Schneider Electric.

Schneider Electric (Australia) Pty LtdCustomer Care Australia: 1300 369 233Email: customercare.au@schneider-electric.comwww.schneider-electric.com.au

Customer care

Warranty informationWe warrant this product for 2 years. For details, please visit http://www.schneider-electric.com.au/en/about-us/legal/terms-and-conditions.jsp.Our goods also come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Manual override option 1

Adjusting the timer and lux settings

min. 2 lx

(Approx.10 mins)

max.15 mins

max.2000 lx

min. 10 secs

Timer

Lux

Installing the skin Removing the skin

Fitting the carrier or zone mask to the skin

Zone masking

1 Remove zone mask segments to allow sensor to detect movement A.

2 Remaining segments prevent detection of movement B.

50°

50°

BAMasked

zone

Manual override option 2

Manual override option 3

Add a 1/2 way switch. Labelled dolly recommended (“Auto/Manual” shown).

Add a 3-position switch. Labelled dolly recommended (“Sensor/Off/On” shown).

C

2

1

N A

A

N

L

LLL

A

A

A

A

A

A

N

N

N PIR MECHANISM

SWITCH (1/2 WAY)

C

2

1

A

N

L

PIR MECHANISM

Optional 2nd sensor + switch(e.g. hallway application)

SWITCH (1/2 WAY)

N L

LOAD

PEPE

A ActiveN NeutralL LoadPE Protective Earth

Technical specifications

C

2

1

N A

A

N

L

N

AA

L

LL

L

L A

A

A A

A

N

NPIR MECHANISM

SWITCH (1/2 WAY)

C

2

1

A

N

L

PIR MECHANISM

Optional 2nd sensor + switch(e.g. hallway application)

SWITCH (1/2 WAY)

N L PEPE

LOAD

A ActiveN NeutralL LoadPE Protective Earth

C

1

2

C

1

2

A

N

L

N

N

N

N

APE

A

N

L

A

PIR MECHANISM

SWITCH (3-POS)

PIR MECHANISM

Optional 2nd sensor + switch(e.g. hallway application)

SWITCH (3-POS)

NL

A

A

A

A

LL

LL

L

LOAD

PE

A ActiveN NeutralL LoadPE Protective Earth

Cabling and connections for option 3

Cabling and connections for option 1

Cabling and connections for option 2

Add a 1/2 way switch.

SensorOffOn

SensorOffOn

A

C

B

A

B

Auto

Manual

Auto

Manual

A

B

Operating voltage 220–240 V a.c., 50 Hz

Load ratings Incandescent lamps: 750 W

Fluorescent lamps: 100 W

LED lamps: 150 W (max. 4 lamps)

Motor: M.3

AC halogen lamps: 400 W

LV halogen lamps: 400 VA

Timer setting range min. 10 s, max. 15 mins

Lux setting range min. 2 lx, max. 2000 lx

Detection technology Passive Infrared (PIR)

Angle of coverage 100° horizontal, 82° vertical

Detection range max. 5 m (at 20–25 °C)

Environmental rating IP20 (for indoor use only)

Operating temperature –10 °C to 50 °C

Compliance AS/NZS 60669-2-1

Specifications typical at 25 °C.

Sensor-activated override• Toggle the switch to position B and back to A within 1.5 seconds.• Sensor toggles the load state On or Off and maintains that state for the

duration of the sensor timer setting.• Sensor resumes normal operation once timer expires.Note: If power to sensor is interrupted for 1.5 seconds, the load is switched on for about 1 minute, then sensor resumes normal operation.

Manual OFF• Operate switch to position B (turns sensor and load Off).• Operate switch to position A to resume sensor operation.

Manual ON• Operate switch to position B to override sensor and keep load On.• Operate switch to position A for normal sensor operation.

Manual OFF• Operate switch to position B (turns sensor and load Off).• Operate switch to position A to resume sensor operation.

Manual ON• Operate switch to position c to override sensor and keep load On.• Operate switch to position A for normal sensor operation.

Manual override options

Depending on the wiring and the type of switch used, the following manual override options are possible:Option 1: Manual override activated by the sensor using a

rocker switch.Option 2: Manual override bypassing the sensor using a

rocker switch.Option 3: Manual override with 3-position switch.

Choose a manual override option to suit the desired operation.

48.5 mm

49 mm 23.5 mm

Manual override option

Desired operation 1 2 3

Switch load On when movement detected. Yes Yes Yes

Switch load Off when no movement detected and sensor timer has expired.

Yes Yes Yes

Manually switch load Off indefinitely until manual switch back to sensor operation.

Yes No Yes

Manually switch load On indefinitely until manual switch back to sensor operation.

No Yes Yes

Manually switch sensor Off indefinitely until manual switch back to sensor operation.

Yes No Yes

Manually switch load Off on exit, then sensor resumes normal operation automatically.

Yes No Yes

Manually switch load On when entering room (e.g. if sensor hasn’t detected movement) then sensor resumes normal operation automatically.

Yes No Yes