Page 1: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

A7877C08/10

Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Installation InstructionsHarmony Series H1Mortise Lock

Page 2: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

A7877C•800-810-WIRE(9473)•www.sargentlock.com2

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

2/10

1

2

3

4

5

6

7

Table of ContentsWarning ...................................................................................2

General Description .................................................................3

Hardware Specifications .........................................................3

Electronics Specifications .......................................................3

Features ...................................................................................3

Parts Breakdown .....................................................................4

Installation Instructions ..........................................................6

Wiring Diagrams ....................................................................14

UL 294 Compliance ................................................................18

Mechanical Operational Check .............................................19

Electrical Operational Check .................................................19

8

9

10

ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.

Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresi-dentialinstallation.

Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethattheinter-ferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:

• Reorientorrelocatethereceivingantenna

• Increasetheseparationbetweentheequipmentandreceiver

• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected

• ConsultthedealeroranexperiencedTVtechnicianforhelp

ThisClassBdigitalapparatuscomplieswithCanadianICES-003.

CetappareilnumériquedelaclasseBestconformeaveclanormeNMB-003duCanada.

met.ThisClassBdigitalapparatusmeetsallrequirementsoftheCanadianInterferenceCausingEquipmentRegula-tions.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.

CetappareillagenumériquedelaclasseBrépondàtouteslesexigencesdel’interférencecanadiennecausantdesrèglementsd’équipement.L’opérationestsujetteauxdeuxconditionssuivantes:(1)cedispositifpeutnepascauserl’interférencenocive,et(2)cedispositifdoitacceptern’importequelleinterférencereçue,ycomprisl’interférencequipeutcauserl’opérationpeudésirée.

Observeprecautionsforhandlingelectrostaticsensitivedevices.!

Warning 1 Warning:Changesormodificationstothisunitnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatetheequipment.

11

Page 3: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com3

Electronics Specifications

General DescriptionTheSARGENTHarmonySeriesH1MortiseLockisdesignedtointerfacewithexistingWiegandElectronicAccessControl(EAC)panels.Thereaderrequires12VDCforpowerandisavailablewith125kHzHIDproxim-itytechnology.TheH1technologyisbackedbySARGENT’sGrade1hardware.ThemortiselockincludesRequesttoExitanddoorpositionmonitoringallinsidethelockbodyandisavailablein12or24VDC.Weath-ersealgasketsarealsoincludedforoutsideuseonexteriordoorapplicationsonly.TheHarmonyH1readerprovidesvisual(LED)andaudibleindicationoflockstate(locked/unlocked).

3

4

2

5 Features• Completemonitoringofdoorviaintegratedlock

• RXSetting(DIP-SwitchConfigurableforN/O,N/Candhanding)

• DoorPosition(IntegratedSecured/Unsecured)

• 24VDClockbodyavailable

• FailSafeorFailSecuresolenoidversion(mustspecify)

• AcceptsallHID125kHzstandardWiegandbitformats

• UsesMcKinneyQC12HingewithElectroLynx®(orderseparately)

Total One-Way Length of

Wire Run (ft)

Load Current @ 12VDC

1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A

100 20 18 16 14 14 12 12 10

150 18 16 14 12 12 12 10 —

200 16 14 12 12 10 10 — —

250 16 14 12 10 10 10 — —

300 16 12 12 10 10 — — —

400 14 12 10 — — — — —

500 14 10 10 — — — — —

750 12 10 — — — — — —

1,000 10 — — — — — — —

1,500 10 — — — — — — —

Total One-Way Length of

Wire Run (ft)

Load Current @ 24VDC

1/4A 1/2A 3/4A 1A 1-1/4A 1-1/2A 2A 3A

100 24 20 18 18 16 16 14 12

150 22 18 16 16 14 14 12 10

200 20 18 16 14 14 12 12 10

250 18 16 14 14 12 12 12 10

300 18 16 14 12 12 12 10 —

400 18 14 12 12 10 10 — —

500 16 14 12 10 10 — — —

750 14 12 10 10 — — — —

1,000 14 10 10 — — — — —

1,500 12 10 — — — — — —

Hardware Specifications• Latch-Stainlesssteel3⁄4”projectionone-piece

• Deadbolt-One-piecehardenedstainlesssteel

• Guardbolt-Stainlesssteel,non-handed

• Handed-Easilyfieldreversiblewithoutopeningcase

• Case-12gaugeheavydutywroughtsteel

• Outsidelevercontrolledbyany125kHzHIDproximitycredential

• InsideleverprovidesRXsignalandretractslatchanddeadbolt

• Doorpositionswitchwithinlockbody

• Locksfurnishedfor1-3/4”doors.Otherdoorthicknessesrequireconfirmationwithfactory.

• ULandCULlistedforuseonFireDoors

• ListedtoUL294(AccessControlSystemUnits)withintheU.S.only

• WirefromEACPaneltodoormustbeshieldedwithdrainterminatedatEACPanelcontroller

12VDC System• ReaderDraw=150mA

• 12VDCSolenoidDraw=500mA

• TotalSystemDraw=650mA

Wire Gauge Charts

24VDC System• ReaderDraw=150mA(Readerisalways12VDC)

• 24VDCSolenoidDraw=250mA

• TotalSystemDraw=400mA

McKinneyElectric

Hinge

HarmonySeriesH1Patented

WiegandAccessControlSystem

HID and Edge are trademarks or registered trademarks of HID Global Corporation.

Sargent Manufacturing Company (New Haven, CT). 2010. U.S. Patent D601,001S; D601,002S; D601,003S; D602,762S.

Page 4: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com4

Parts Breakdown6

Left Hand Reverse Door

Tools Required:•PhillipsScrewDriver(Standardsize)

•SlottedScrewDriver(Standardsize)

•1/8"AllenWrench

11A

2

3

5

66A

5

13

13

11A

11

10

9

14

17

1515A 19

16

8

18

20

7

Page 5: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com5

ITEM PART # Description Req.

1 52-5188 Outside Harmony Escutcheon With Cylinder Prep 1

1A 52-5189 Outside Harmony Escutcheon Without Cylinder Prep 1

2 52-0796 Outside Weather Gasket 1

3 52-0795 Inside Weather Gasket 1

5 52-5236 Screw Pack (5A; 5B; 5C; 5D) 1

5A 77-1467 8 x 32 x 2" Phillips Head Flat Head Machine Screw 2

5B 01-9242 8 x 32 x 5/8" Phillips Head Flat Head Undercut Machine Screw 2

5C 01-1028 8 x 32 x 1/4"Phillips Head Flat Head Undercut Machine Screw 1

5D 01-1176 8 x 32 x 3/8" Phillips Head Flat Head Undercut Tapping Screw 4

6 52-5184 Inside Escutcheon w/ Turn Assembly 1

6A 52-5185 Inside Escutcheon w/out Turn Prep 1

7 Reference Harmony Series Catalog For Available Lever Styles 1

8 Reference Harmony Series Catalog For Available Rose Styles 1

9 82-0368 Inside Spindle 1

10 01-1495 8-32 x 5/8" Screws 2

11 82-3088 Inside Adapter Plate And Bushing Assembly 1

11A 82-4577 Inside Adapter Plate And Bushing Assembly (Dl) 1

12 Reference Harmony Series Catalog For Available Lever Styles 1

13 Reference Harmony Series Catalog For Available Cylinders (Size 43) 1

14 Lock Body "H1-82270-12/24 VDC x Finish" w/out Deadbolt, Fail Safe 1

"H1-82271-12/24 VDC x Finish" w/out Deadbolt, Fail Secure 1

"H1-82272-12/24 VDC x Finish" w/out Deadbolt, Fail Safe, Both Levers Lock 1

"H1-82273-12/24 VDC x Finish" w/out Deadbolt, Fail Secure, Both Lever Lock 1

"H1-82280-12/24 VDC x Finish" w/ Deadbolt, Fail Safe 1

"H1-82281-12/24 VDC x Finish" w/ Deadbolt, Fail Secure 1

"H1-82282-12/24 VDC x Finish" w/ Deadbolt, Fail Safe, Both Levers Lock 1

"H1-82283-12/24 VDC x Finish" w/ Deadbolt, Fail Secure, Both Levers Lock 1

15 82-0579 Outside Faceplate w/ Deadbolt 1

15A 82-0578 Outside Faceplate w/out Deadbolt 1

16 82-0110 Strike Plate 1

17 01-2299 #12 X 1 1/4" Phillips Flat Head Wood Screw 2

18 01-1019 12-24 X 1/2" Phillips Flat Head Undercut Machine Screw 4

19 01-1028 8-32 X 1/4" Phillips Flat Head Undercut Machine Screw 2

20 01-2298 #12 X 1" Phillips Flat Head Wood Screw 2

21 A7944 Field Prep Template (not shown) 1

21B 4590 Door Manufacturer Template (not shown) 1

22 A7877 Installation Instructions (not shown) 1

Parts Breakdown (Continued)Left Hand Reverse Door

Page 6: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com6

Installation Instructions7

Step #1 – Door Preparation

LeftHandHingesLeft.

OpenInward.“LH”

LeftHandReverseBevelHingesLeft.

OpenOutward“LHRB”

RightHandHingesRight.OpenInward.

“RH”

RightHandReverseBevelHingesRight.OpenOutward

“RHRB”

A. Verify Hand and Bevel of Door

Standonoutsideoflockeddoorwhendeterminingdoorhand.

B. Door PreparationPreparedooraccordingtoappropriatetemplate.Ifnecessary,refertowebsite,www.intelligentopenings.com:

•Priortoinstallation,makesureallholesarefreeofburrs,debrisandsharpedges.

•IfdoorsarenotproperlyreinforcedperANSI115.2,commerciallyavailablereinforcementsshouldbeinstalled.

•Templates:

oField:A7944templateshipswithproduct.

oManufacturer:4590metalandwooddoor.

Fig. 1A

Outside of Door Inside of Door

Racewayfor12ConductorNetwork/PowerCable(ElectroLynx)fromMcKinney

HoleforCablefromReadertoControllerBoard

Pre-drilledand/orTappedHoles(2places)

InsideCylinderHole

Through-boltHoles(2places)

OutsideCylinderHole(70/71,80/81

functionsonly)

LeverHandleHole

ThumbTurnHole

LeverHandleHole

MortiseArea

Pre-drilledand/orTappedHoles(2Places)

Fig. 1B Wood Door

Page 7: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com7

TriangularSlot

Latchbolt

Installation Instructions (Continued)Step #2 – How to Reverse Lock Hand/Latch

Redsurfaceoflockingpiecemustfacetheoutside/lockedsideofdoor.Torotatelockingpiece(Fig.2A):

1.Positionlockbodywithredsurfaceoflockingpiecevisible.

2.Insertslottedscrewdriverintolockingpieceslottorotatelockingpiecetowardbackoflockbody.

3.Rotatethelockingpiece180°untilREDsurfaceisonoppositeside.

Note:Redindicateslockedside(outside).

WireharnessMUSTexitthroughnon-cylinderside.

Makesuretheplasticretainingringisseatedcorrectly(Fig.2B):

A. Reverse Lock Hand

C. Reverse Latch HandBeveledsurfaceoflatchmustfacestrike(Fig.2C).

Thedeadlatchisselfadjusting.

Tochangehandoflatchbolt:

1.Insertscrewdriverbladeintothespadeshapedslot.

2.Rotatescrewdriver90ºtopushlatchoutuntilbackoflatchclearslockfront;thenrotatelatch180º.

Latchwillthenre-enterlockbody.

Note:Latchcannotbeunscrewed.

IMPORTANT:Mustsetthe4positionDIP-switchRXsettingslocatedontherearofthemortiselockbodypriortolockinstallation(Step3).

Fig. 2C

Fig. 2A

LockingGuideSlot:Redcolorindicates

lockedside.

PushIn

Right HandLock Shown

PlasticRetainingRing

Outside of Door

Fig. 2B

B. Retaining RingMakesuretheplasticretainingringisseatedcorrectly(Fig.2B):

1.Thewiresandtheplasticretainingringmustbelocatedonthenon-cylinderside.

2.OrienttheplasticretainingringsothatthewordBottomislocatedatthebottomofthecylinderhole.

3.Routethewiresfromthetopofthecyl-inderholeintotheslotonthetopoftheplasticretainingring,NOTthroughtheretainingring.

Page 8: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com8

BlackcirclesindicatepositionofDIPswitchFig. 3B

LeftHandHingesLeft.

OpenInward.“LH”

LeftHandReverseBevelHingesLeft.

OpenOutward.“LHRB”

RightHandHingesRight.OpenInward.

“RH”

RightHandReverseBevelHingesRight.

OpenOutward.“RHRB”

Step #3 – Mortise Lock Body RX Switch Settings Four Position DIP (Dual Inline Practice) SwitchThefourpositionDIPswitchRXsettingslocatedontherearofthemortiselockbodymustbesetpriortolockinstallation.

Setfour-positionDIPswitchsettingforappropriatedoorapplication.BesuretofollowthedirectionsontheRXDIPSwitchstickerexactly.

FailuretofollowstickerdirectionswillcauseinaccurateRXactivitytobereportedtotheaccesscontrolpanel.

Fig. 3A

Step #4 – Install Lock Body Wiresandconnectorsgointothemortisedareaandoutoftheinsidecylinderhole.

1.Insertmortiselockbodyintomortisedoorpreparation.

2.Carefullyfeedwiresfrommortiselockthroughthenon-cylindersideholeofthedoorpreparation.

3.Installappropriatehardwarelockbodyscrews.

NOTE:Donottightenscrewscompletelyatthistime.

Cylindershouldbeinstalledpriortotightening.

Inside of Door

(2)#12x1-1/4”LongF!atHeadWoodScrews(WoodDoors)

Fig. 4A

(2)#12-24x1/2”LongFlatHeadPhilipsScrews(MetalDoors)

Feedconnectorsandwiresthroughnon-cylinderside.

ON

ON

1234

1234

ON

ON

1234

1234

LHandLHReverseDoor

NormallyOpen

NormallyClosed

RHandRHReverseDoor

NormallyOpen

NormallyClosed

Page 9: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com9

Fig. 5B

Requiredforexteriordoorapplications

ReaderCable

Outside of Door

Step #6 – Install GasketAddGasket(ifnecessary):

Remembertoplacetheinsidegasketwheninstallinginanoutdoorapplication.

Gasketfitssnugaroundplateattopandsides,leavingroomfortheholeatthebottom.

Removebackingandplacegasketondoor(Fig.6A).

Requiredforexteriordoorapplications.

Fig. 6A

Inside of Door

Fig. 5A

(2)8-32x3/8”PhillipsFlatHeadUndercutComboScrew

(2)8-32x3/8”PhillipsFlatHeadScrew

Inside of Door

Step #5 – Outside Escutcheon and Inside Mounting Plate InstallationNOTE:Feedmortiseconnectorsthroughthecorrespondingholeonthemountingplate.

1.Attachthemountingplateusing(2)8-32x3/8"Phillipsflatheadundercutcomboscrewsintheupperleftandmiddlerightpositionsofthemountingplateand(2)8-32x3/8"Phillipsflatheadscrewsinthebottompositions(Fig5A).

2.Feedthereadercablelocatedonthebackoftheoutsideescutcheonthroughthedoorprep.Remember,theoutsidegasketmustbeusedwheninstallingHarmonyinanoutdoorapplication(Fig5B).

3.Securethemountingplatetotheoutsideescutcheonwith(2)#8-32x2”flatheadmachinescrews(Fig5C).

Page 10: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com10

Step #7 – Connect Earth GroundConnectpin5green/yellowgroundwireringterminaltotoprightscrew.

Fig. 7B Detail

Fig. 7A

(2)#8-32x2”PhillipsFlatHeadMachineScrew

Fig. 8B

Step #8 – Outside Cylinder Installation1.VerifyorientationofcylindersothatSARGENTlogoisright-sideup(Fig.8A).

2.Withdrawthekeyabout25%outofthecylinderbeforeinsertingintotheescutcheon(Fig8B).

3.UsethekeytorotatethecylinderclockwiseuntilitisflushatthebottomandtheSARGENTlogoisright-sideup.

Donotattempttotightenalltheway.

4.Tightenthecylinderclampsetscrewtopreventunscrewingofthecylinder(Fig8C).

5.Testcylinderfunction:

• 70/71Function:Keyretractslatch.

• 80/81Function:Keyretractslatchandprojectsandretractsdeadbolt.

• Ensuresmoothoperationoflatchboltanddeadbolt.

NOTE:Useleverhandleholestomanipulatemortisetoeasethreadengagementofcylinder.

Fig. 8C

CylinderSetScrew

PhillipsScrewdriver

Outside of Door

IMPORTANT:PositioncylindersothattheSARGENTlogoisright-sideup.

Correct Incorrect

Fig. 8A

Page 11: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com11

Step #9 – Install Outside Lever and Inside Adapter Plate Assembly 1.Withoutsideleverhorizontal,insertthemountingpostthroughoutsideofdoorandlockbody.

Makecertaintheleverspindleisproperlyengagedinsidethelockbody(Fig9A).

2.Ontheinsideofthedoor,insertspindleintosquareholeofmortiselock(Fig9B).

3.Slideinsideadapterandplateassemblyoverspindleandlooselysecurewith(2)8-32X5/8”Phillipsovalheadandlockwashermachinescrews.

Besuretorotatethesetscrewholesothehole(StudioCollectiononly)facesthehingesideandseattheinsidespindlefullyintothelockbody.

4.Securelytightenthelockbodyscrews.

Fig. 9BFig. 9A

MortiseLockbodyScrew

8-32X5/8”PhillipsOvalHeadandLockWasherMachineScrew

MortiseLockbodyScrew

Step #10 – Attach Connectors (Interior PCB Assembly) 1.ConnectP3(2-pinconnector)fromlockbodytoJ3oninteriorPCBassembly.

2.ConnectP4(6-pinconnector)fromlockbodytoJ4oninteriorPCBassembly.

3.ConnectP5(7-pinconnector)fromReaderboardtoJ5oninteriorPCBassembly.

4.ConnectElectroLynxharness(4and8-pin)fromdoorharnesstoElectroLynxharnessoninteriorPCBassembly.

NOTE:Connectorsgoononlyoneway.

Donotoffsetconnectorandbesuretheyarecompletelyseated.

Fig. 10A

Inside of Door

Outside of Door

PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)J2 J1

1-Violet Lock Neg

(Solenoid, neg)

3-Pink

DPS (NC)

1- Black

PWR NEG

3-White

DATA 1

5-Orange

RX (NO/NC)

7-Brown

EGND

2-Gray Lock Pos

(Solenoid, pos)

4-Tan

DPS (COM)

2-Red

PWR POS

4-Green

DATA 0

6-Blue

RX (COM)

8-Yellow

LED

J 5

J 4 J 3

FromReaderBoardP5toJ5

FromLockBodyP3toJ3

FromLockBodyP4toJ4

ToElectroLynxHarness

J1J2

Page 12: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com12

Step #11 – Position Outside WiresPleasefollowthesestepspriortoinstallinginsideescutcheonassemblytopreventanydamagecausedbypinchingwires:

1.InserttheElectroLynxconnectors(8and4-pin)andestablishtheirpositioninsidethedoorprep(Fig.11A).

2.Neatlyfoldthewiresontothemselvesandintotheremainingspacetopreventpinchingofwireswhenmountingescutcheon(Fig.11B).

Donottuckextramortiselockbodywiresbackinsidethelockbodycylinderhole.

Fig. 11A Fig. 11B

Outside of Door

Step #12 – Install Inside Escutcheon Assembly1.TightentheinsideescutcheonsecurelytothemountingplatewiththePhillipsflatheadmachinescrewsprovided.Usethe8-32x5/8”forthetopoftheescutcheonandthe8-32x1/4”screwsforthebottomoftheescutcheonlocatedundertheturnlever.RemembertheinsidegasketmustbeusedwheninstallingHarmonyinanoutdoorapplication.

2.Besuretheturnassemblyisfunctionalandthedeadboltfunctionsproperly.

Requiredforexteriordoorapplications.

Fig. 12A

8-32X1/4”PhillipsFlatHeadUndercutMachineScrew

8-32X5/8”PhillipsFlatHeadUndercutMachineScrew

Inside of Door

Page 13: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com13

Step #13 – Install Inside Rose and Inside Lever Assembly 1.Rotatetheinsiderose-firstcounterclockwisetoseatthethreadsandthen,clockwisetosecurelytighten.

2.Slideleverhandleontospindleuntilfullyseated.Besurehandleishorizontalandfacingthehingesideofthedoor.Pushleverontospindlesominimumgapisvisible.

3.Tightenthesetscrewsecurelywitha1/8”hexwrench.

4.Beforeclosingthedoor,testthatleverisfunctionalandensuresmoothoperationofthelatchboltanddeadbolt.

Fig. 13A Fig. 13B

Step #14 – Attach Front Plate1.Attachfrontplatewith(2)8-32x1/4”flatheadscrewsandtightensecurely.

Fig. 14A

SetScrew

InsideLever

Spindle

Inside of Door

(2)8-32x1/4”FlatHeadScrews

LockBodyScrew

LockBodyScrew

Rose

Outside of Door

Page 14: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com14

Product 8PINCONNECTION 4PINCONNECTOR

1-Black 2-Red 3-White 4-Green 5-Orange 6-Blue 7-Brown 8-Yellow 9-Violet 10-Gray 11-Pink 12-Tan

ACCESSCONTROLDEVICES:HarmonyH1Mortise,ElectroLynxwireColor/Functionassignments

12VDCReaderPower

WIE-GAND

WIE-GAND

RX(NO/NC)

RX(COM)

EGND LED 12OR24VDC(LOCKRELAY

DPS(NC)

DPS(COM)

SARGENT-HARMONY

SERIES,H1Mortise

NEG POS DATA_1 DATA_0 REF.STEP2A

REF.STEP

2A

REF.DIA-

GRAMS

REF.DIA-

GRAMS

NEG POS DPS DPS

Wiring Diagrams8

Reader LED ConfigurationTheHarmonySeriesreadercanbeconfiguredfor(3)modesofLEDoperation:

Mode 1:•RedLED‘ON’whenpowered.

•Presentinga125kHzproximitycardwillcauseLEDto‘FLICKER’GreenandreturntoRedstate.

•ReferenceDiagram#1orDiagram#4asafunctionofpowerrequirement(12VDCor24VDC).

Note:LEDwireisunconnected.

Mode 2:•GreenLED“ON”whenpowered.

•(NoFlicker)afterpresentingvalid125kHzproximitycard.

•ReferenceDiagram#2orDiagram#5asafunctionofpowerrequirement(12VDCor24VDC).

Note:LEDwiremustbeconnectedtocircuitGROUNDofthesystem’spowersupply.

Mode 3:•EACPanelcontrolsLEDoperation.

•ReferenceDiagram#3orDiagram#6asafunctionofpowerrequirement(12VDCor24VDC).

Note:ControlofLEDisafunctionoftheEACpanelequipment(ie.Relay)totogglebetweenGreen&Red.

Note:WhenLEDwireistieddirectlyintoEACpanelrelay,noACsignalsshouldbeappliedonwireordoorreaderperformancewillbeimpacted(Ref.Diagram#3orDiagram#6).

PIN8 (Yellow – LED)PIN 6 (Blue – RX)

PIN 4 (Green – Data 0)PIN 2 (Red – Reader POS)

PIN 1 (Black – Reader NEG)PIN 3 (White – Data 1)

PIN 5 (Orange – RX)PIN 7 (Brown)

PIN 4 (Tan – DPS)PIN 2 (Gray – Lock POS)

PIN 1 (Violet – Lock NEG)PIN 3 (Pink – DPS)

Page 15: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com15

Typical Harmony Mortise Application Diagram (12VDC Lock)

DIAGRAM #1 – MODE 1: LED WIRE NOT USED = RED LED ON WHEN POWERED

12VDC System• ReaderDraw=150mA

• 12VDCSolenoidDraw=500mA

• TotalSystemDraw=650mA

*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.

Failure to follow proper ESD safe grounding procedures could lead to equipment failure.

Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)

Reader Electronics Requires 12VDC Filtered and Regulated

READERNEG-Black,1

READERPOS-Red,2

DATA1-White,3

DATA0-Green,4

RX(NO/NC)-Orange,5

RX(COM)-Blue,6

*EGND-Brown,7

LED-Yellow,8

LOCKNEG-Violet,9

LOCKPOS-Gray,10

DPS(NC)-Pink,11

DPS(COM)-Tan,12

NotUsed

12/24VDC

HNG

-+

120VACInput

H1 Harmony Series

(-)12VDC

(+)

DATA1

DATA0

RX

RX

Electronic Access Control

Panel (By Others)

Use(NC)forFailSafe

Operation

Lock Relay

(NO)FailSecure

Operation

DPS

DPS

Black(Hot)

White(N

eutral)

G

reen(Gnd)

12ConductorElectroLynxHarness

FromMcKinney

QC12ElectricHingeFromMcKinney

24VDC System• ReaderDraw=150mA(readeralways12VDC)

• 24VDCSolenoidDraw=250mA

• TotalSystemDraw=400mA

LockbodyPower Supply(By Others)

Page 16: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com16

DIAGRAM #2 – MODE 2: LED WIRE TIED TO GROUND = GREEN LED ‘ON’ WHEN POWERED

Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)

*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.

Failure to follow proper ESD safe grounding procedures could lead to equipment failure.

Typical Harmony Mortise Application Diagram (12VDC Lock)

Black(Hot)

White(N

eutral)

G

reen(Gnd)

12/24VDC

HNG

-+

120VACInput

H1 Harmony Series

(-)12VDC

(+)

DATA1

DATA0

RX

RX

Electronic Access Control

Panel (By Others)

Use(NC)forFailSafe

Operation

Lock Relay

(NO)FailSecure

Operation

READERNEG-Black,1

READERPOS-Red,2

DATA1-White,3

DATA0-Green,4

RX(NO/NC)-Orange,5

RX(COM)-Blue,6

*EGND-Brown,7

LED-Yellow,8

LOCKNEG-Violet,9

LOCKPOS-Gray,10

DPS(NC)-Pink,11

DPS(COM)-Tan,12DPS

DPS

12ConductorElectroLynxHarness

FromMcKinney

QC12ElectricHingeFromMcKinney

12VDC System• ReaderDraw=150mA

• 12VDCSolenoidDraw=500mA

• TotalSystemDraw=650mA

Reader Electronics Requires 12VDC Filtered and Regulated

24VDC System• ReaderDraw=150mA(readeralways12VDC)

• 24VDCSolenoidDraw=250mA

• TotalSystemDraw=400mA

LockbodyPower Supply(By Others)

Page 17: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com17

DIAGRAM #3 – MODE 3: LED WIRE TO EAC PANEL = EAC PANEL CONFIGURABLE

Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)

*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.

Failure to follow proper ESD safe grounding procedures could lead to equipment failure.

Typical Harmony Mortise Application Diagram (12/24VDC Lock)

(-)12VDC

(+)

DATA1

DATA0

RX

RX

LED

Electronic Access Control

Panel (By Others)

Use(NC)forFailSafe

Operation

Lock Relay

(NO)FailSecure

Operation

LockbodyPower Supply(By Others)12/24VDC

HNG

-+

120VACInput

H1 Harmony Series

Black(Hot)

White(N

eutral)

G

reen(Gnd)

READERNEG-Black,1

READERPOS-Red,2

DATA1-White,3

DATA0-Green,4

RX(NO/NC)-Orange,5

RX(COM)-Blue,6

*EGND-Brown,7

LED-Yellow,8

LOCKNEG-Violet,9

LOCKPOS-Gray,10

DPS(NC)-Pink,11

DPS(COM)-Tan,12DPS

DPS

12ConductorElectroLynxHarness

FromMcKinney

QC12ElectricHingeFromMcKinney

12VDC System• ReaderDraw=150mA

• 12VDCSolenoidDraw=500mA

• TotalSystemDraw=650mA

Reader Electronics Requires 12VDC Filtered and Regulated

24VDC System• ReaderDraw=150mA(readeralways12VDC)

• 24VDCSolenoidDraw=250mA

• TotalSystemDraw=400mA

Page 18: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

Cop

yrig

ht ©

201

0, S

arge

nt M

anuf

actu

ring

Com

pany

, an

AS

SA

AB

LOY

Gro

up c

ompa

ny. A

ll rig

hts

rese

rved

. R

epro

duct

ions

in w

hole

or

in p

art w

ithou

t exp

ress

writ

ten

perm

issi

on o

f Sar

gent

Man

ufac

turin

g C

ompa

ny is

pro

hibi

ted.

08/0

1/10

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com18

9 UL 294 ComplianceHarmony H1 8200 UL 294 Application DiagramUL 294 Requirements• HIDEDGEE400orES400

• POEInjectorAltronixNetway1

• SARGENT3540/SecuritronBPS-24-2

• HES2001MMOV/Bridge(Optional)

• LEDWireUseasRequired

12ConductorElectroLynxHarness

FromMcKinney

QC12ElectricHingeFromMcKinney

Harmony Series H1

P22GND

P23PWR

P23DATA1

P23DATA0

P106REX(+)

P106REX(-)

P105DSCOM

P105DSNO

P106DOORMON(+)

P106DOORMON(-)

READERNEG-Black,1

READERPOS-Red,2

DATA1-White,3

DATA0-Green,4

RX(NO)-Orange,5

RX(COM)-Blue,6

EGND-Brown,7

LED-Yellow,8

LOCKNEG-Violet,9

LOCKPOS-Gray,10

DPS(NC)-Pink,11

DPS(COM)-Tan,12

HES

2001M

P1

P2

P3

P4

R1

R2

R3

R4

H

F2

FA

F1

H

N

G 120

VAC

Inp

utFi

reA

larm

Con

tact

s

24V

DC

Pos

itive

Out

put

s24

VD

CN

egat

ive

Out

put

s

ToN

CF

ireA

larm

Con

tact

s

120VAC

HID EDGE E400/ES400

RJ45PORT

ALTRONIX NETWAY1

OUTIN

ALTRONIXRJ45PORTS

ALTRONIXPOWERINPUTS

NON-POLAR

CAT5e OR GREATER

CABLE

IN used for Networking/

Monitoring Connection

TapePurple/BlackWires(Unused)

Red

Red/Green

Black

Black

*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.

Failure to follow proper ESD safe grounding procedures could lead to equipment failure.

*UL 294 is a United States based standard.

UseasRequired

Page 19: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

08/0

1/10

Copy

right

© 2

010,

Sar

gent

Man

ufac

turin

g Co

mpa

ny, a

n AS

SA A

BLOY

Gro

up co

mpa

ny. A

ll rig

hts r

eser

ved.

Re

prod

uctio

ns in

who

le o

r in

part

with

out e

xpre

ss w

ritte

n pe

rmiss

ion

of S

arge

nt M

anuf

actu

ring

Com

pany

is p

rohi

bite

d.

Harmony Series H1 Mortise Lock

A7877C•800-810-WIRE(9473)•www.sargentlock.com19

For82280-82283&82270-82273Functionmortiselockswithcylinders:

1.Insertkeyintocylinderandrotate:Thereshouldbenofrictionagainstlockcase,wireharnessoranyotherobstructions.

2.Thekeywillretractthelatch:Keyshouldrotatefreely.

3.Whenthedeadboltisthrown:Ensurethatthekeyretractsboththedeadboltandthelatch.

4.Insidelever:Whenused,ensureitretractsboththelatchanddeadbolt(ifprovided).

5.Closedoor:Ensurelatchanddeadboltfullyextendanddonotbind.

Mechanical Operational Check

Note:Onceelectricalwiringhasbeensuccessfullycompletedaccordingtoproperapplication,followthefollowingstep:

1.TurnpowerON.

2.VerifyLEDlocatedonreaderisON(RedorGreendependingonreaderconfiguration(SeereaderLEDConfiguration).

3.PresentproximitycredentialandverifyLEDandsounderactivity.

4.VerifyvalidcardreadatEACpanel.

5.Verifysystemoperationfunctions;i.e.,whenProxcredentialispresentedtoreaderthatthedoorunlocks.

Electrical Operational Check

10

11

Page 20: Installation Instructions Harmony Series H1 Mortise Lock H1...The SARGENT Harmony Series H1 Mortise Lock is designed to interface with existing Wiegand Electronic Access Control (EAC)

A7877C-08/10

SARGENT Manufacturing100 Sargent DriveNew Haven, CT 06511 USA800-727-5477 • www.sargentlock.com

Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,electro-mechanical products and access control systems for new construction, renovation, and replacement applications.The company’s customer base includes commercial construction, institutional, and industrial markets.

Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

ASSA ABLOY is the global leader in door opening solutions, dedicated tosatisfying end-user needs for security, safety and convenience.