installation instructions -...

12
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53300104-01 Printed in U.S.A. Form 30/38-11SI Pg 1 11-12 Replaces: 30/38-7SI Installation Instructions Part Number 38AP-900---022 CONTENTS SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10 Install Harness and Make Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Controls Configuration for EMM Options . . . . . . . . . 6 SAFETY CONSIDERATIONS Installation of this accessory can be hazardous due to sys- tem pressures, electrical components, and equipment loca- tion (such as a roof or elevated structure). Only trained, qualified installers and service technicians should install, start up, and service this equipment. When installing this accessory, observe precautions in the literature, labels attached to the equipment, and any other safety precautions that apply. Follow all safety codes. Wear safety glasses and work gloves. Use care in handling and installing this accessory. GENERAL The energy management module (EMM) accessory (Fig. 1) package is required for additional temperature reset, de- mand limit, and remote set point features of the Com- fortLink controls for 30MP, 30RAP and 38AP units. Chilled water temperature reset by return water, outside air or space temperature do NOT require the addition of this ac- cessory. The following additional features are supported by this accessory: temperature reset by 4 to 20 mA field-supplied signal. demand limit control via field-supplied two-step switch input. demand limit control by 4 to 20 mA field-supplied signal. support of unoccupied operation for ice making through field-supplied contacts (30MP, 30RAP only). cooling set point control by 4 to 20 mA field-supplied signal. ACCESSORY PACKAGE CONTENTS LEGEND INSTALLATION NOTE: Component arrangement drawings and wiring dia- grams show available options that may not be applicable to your unit. 1. Inspect the package contents for missing or damaged parts. File a claim with shipping agency if parts are dam- aged. Notify your Carrier representative if any items are missing. 2. Open and tag all electrical disconnects. 3. Access control box: a. Model 30RAP010-030, 30MP015-045 and 38AP025-030 units: Open control box door and remove inner cover. b. Model 30RAP035-150 and 38AP040-130 units: Open center control box door. 4. For 30RAP and 38AP units, loosen the four screws secur- ing the scrolling marquee display bracket. Lift the bracket up and slide it in the holding slots at the top of its mount- ing bracket. For 30MP units, carefully suspend the display bracket from the wiring harness. WARNING Electrical shock can cause personal injury and death. Shut off all power to this equipment during installation. There may be more than one disconnect switch. Tag all discon- nect locations to alert others not to restore power until work is completed. ITEM PART NO. QUANTITY Energy Management Module 30GT515218 1 Harness (38APD,S025-060) 38APHLSBCE-A00 1 Harness (38APD,S065-130) 38APHLSLCE-A00 1 Harness, EMM to LVT (30RAP, 30MP) 38APHSCALE-A00 1 Harness, EMM to MBB/EXV (Power - 30RAP, 30MP) 38APHSCALECA10 1 Harness, EMM to MBB/EXV (Comm. - 30RAP, 30MP) 38APHSCALECA00 1 Harness, EMM to AUX (Comm. - 30RAP, 30MP) 38APHSCALXCA00 1 Screw, no. 6, 1-in. long AL56AU130 1 Wire Tie 4 EXV Electronic Expansion Valve LVT Low Voltage Terminal MBB Main Base Board WARNING Before beginning installation of this equipment, be sure all power to the unit is disconnected, and that tags are properly placed to alert others. Electrical shock can cause personal injury and death. 30MP015-045, 30RAP010-150 38APD025-130, 38APS025-065 Energy Management Module (EMM) Accessory 50/60 Hz

Upload: duongkhuong

Post on 26-Mar-2018

226 views

Category:

Documents


1 download

TRANSCRIPT

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53300104-01 Printed in U.S.A. Form 30/38-11SI Pg 1 11-12 Replaces: 30/38-7SI

Installation InstructionsPart Number 38AP-900---022

CONTENTS

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10Install Harness and Make Wire

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Controls Configuration for EMM Options . . . . . . . . . 6

SAFETY CONSIDERATIONS

Installation of this accessory can be hazardous due to sys-tem pressures, electrical components, and equipment loca-tion (such as a roof or elevated structure).Only trained, qualified installers and service techniciansshould install, start up, and service this equipment.When installing this accessory, observe precautions in theliterature, labels attached to the equipment, and any othersafety precautions that apply.• Follow all safety codes.• Wear safety glasses and work gloves.• Use care in handling and installing this accessory.

GENERALThe energy management module (EMM) accessory (Fig. 1)package is required for additional temperature reset, de-mand limit, and remote set point features of the Com-fortLink controls for 30MP, 30RAP and 38AP units.Chilled water temperature reset by return water, outside airor space temperature do NOT require the addition of this ac-cessory. The following additional features are supported bythis accessory:• temperature reset by 4 to 20 mA field-supplied signal.• demand limit control via field-supplied two-step switch

input.• demand limit control by 4 to 20 mA field-supplied

signal.• support of unoccupied operation for ice making through

field-supplied contacts (30MP, 30RAP only).• cooling set point control by 4 to 20 mA field-supplied

signal.

ACCESSORY PACKAGE CONTENTS

LEGEND

INSTALLATION

NOTE: Component arrangement drawings and wiring dia-grams show available options that may not be applicable toyour unit.

1. Inspect the package contents for missing or damagedparts. File a claim with shipping agency if parts are dam-aged. Notify your Carrier representative if any items aremissing.

2. Open and tag all electrical disconnects.3. Access control box:

a. Model 30RAP010-030, 30MP015-045 and38AP025-030 units: Open control box door andremove inner cover.

b. Model 30RAP035-150 and 38AP040-130 units:Open center control box door.

4. For 30RAP and 38AP units, loosen the four screws secur-ing the scrolling marquee display bracket. Lift the bracketup and slide it in the holding slots at the top of its mount-ing bracket. For 30MP units, carefully suspend the display bracketfrom the wiring harness.

WARNING

Electrical shock can cause personal injury and death. Shutoff all power to this equipment during installation. Theremay be more than one disconnect switch. Tag all discon-nect locations to alert others not to restore power until workis completed.

ITEM PART NO. QUANTITYEnergy Management Module 30GT515218 1Harness (38APD,S025-060) 38APHLSBCE-A00 1Harness (38APD,S065-130) 38APHLSLCE-A00 1Harness, EMM to LVT(30RAP, 30MP) 38APHSCALE-A00 1

Harness, EMM to MBB/EXV(Power - 30RAP, 30MP) 38APHSCALECA10 1

Harness, EMM to MBB/EXV(Comm. - 30RAP, 30MP) 38APHSCALECA00 1

Harness, EMM to AUX(Comm. - 30RAP, 30MP) 38APHSCALXCA00 1

Screw, no. 6, 1-in. long AL56AU130 1Wire Tie — 4

EXV — Electronic Expansion ValveLVT — Low Voltage TerminalMBB — Main Base Board

WARNING

Before beginning installation of this equipment, be sure allpower to the unit is disconnected, and that tags are properlyplaced to alert others. Electrical shock can cause personalinjury and death.

30MP015-045, 30RAP010-15038APD025-130, 38APS025-065

Energy Management Module (EMM) Accessory50/60 Hz

2

5. Using the no. 6 screw provided and the existing retainingclips in the control box, mount the EMM module to theback of the control box. See Fig. 2-8 for the mounting lo-cation of each unit.

6. The board address is set through a 4-position DIP switch.All switches should be set to ON.

CEBD430351-0396-01C

TE

ST

1

CE

PL1

3035

1-01

PW

R

TEST 2

J1 J2

J4 J3

J5

J6J7

LEN

STATUS

RED LED - STATUSGREEN LED -LEN (LOCAL EQUIPMENT NETWORK)

ADDRESSDIP SWITCH

Fig. 1 — EMM Board

LVT

Fig. 2 — Mounting EMM — 38AP025-030 Units

LEGEND

CB — Circuit BreakerEMM — Energy Management ModuleEQUIP — EquipmentGND — GroundLVT — Low Voltage TerminalMBB — Main Base Board

TB — Terminal BlockTRAN — Transformer

Terminal Block Connection a30-4937

3

LVT

LVT

EMM EXV

LON

AUX

UPC

TB1 TB4

CSB-A1

MBB

CHCCCB

FB-1TRAN

DISCONNECTOPTION/TB

C-A1MM

MS-CWP1

CWP1

MS-CWP2

CWP2

LVT

Fig. 4 — Mounting EMM — 38AP065-130 Units

Fig. 5 — Mounting EMM — 30RAP010 and 015 Units

LEGEND FOR FIG. 3-5

CB — Circuit BreakerCCB — CompressorCircuit BreakerCXB — Compressor Expansion BoardEMM — Energy Management ModuleEQUIP — EquipmentGND — GroundLVT — Low Voltage Terminal

MBB — Main Base BoardTB — Terminal BlockTRAN — Transformer

Terminal Block Connection

Fig. 3 — Mounting EMM — 38AP040-060 Units a30-4938

a30-4939

a30-4940

4

a30-4941

a30-4942

EMM EXV

CCB-1

TB1

TB4

CHC

AUX

LON UPC

FC1/MM

CSB-A1

MBBC-A1

FB-3TRAN

CCB-2

CSB-A2

DISCONNECTOPTION/TB

FC2 C-A2

FB-1

CWP1 CWP2

MS-CWP1

MS-CWP2

LVT

TRAN-1

CB-1 CB-2 FCB-1/2/3

TRAN-2CSB-A1 CSB-A2

C-A1

FR-1 FR-2

C-A2

FC-1MM

FC-2 FC-3

AUX LON

EMM EXV

UPC

TB1

TB4

MBB

MS-CWP1

MS-CWP2

FR-3

C-B1

CSB-B1

CB-3CHC

CWP1 CWP2FR-4

CSB-B2

C-B2

CB-4

DISCONNECTOPTION/TB

LVT

Fig. 6 — Mounting EMM — 30RAP018-030 Units

Fig. 7 — Mounting EMM — Typical 30RAP035-150 Units, 035-060 Shown

LEGEND FOR FIG. 6 AND 7

CB — Circuit BreakerCCB — Compressor Circuit BreakerEMM — Energy Management ModuleEQUIP — EquipmentGND — GroundLVT — Low Voltage TerminalMBB — Main Base Board

TB — Terminal BlockTRAN — Transformer

Terminal Block Connection

5

Install Harness and Make Wire Connections38AP025-060 UNITS WITH AUX BOARD — Perform thefollowing procedure to install the harness and make the wiringconnections. See Fig. 9 for wiring.

1. Disconnect the MBB-J3 connector and plug it into theEMM-J3 connector.

2. Install the new harness 38APHLSBCE-A00 provided.a. Install plug labeled MBB-J3 to MBB-J3 and other

end labeled EMM-J4 to EMM-J4.b. Install plug labeled MBB-J2 connector to MBB-J2

and other end labeled EMM-J1 to EMM-J1.c. Install plugs labeled EMM-J6 and J7 to EMM-J6

and J7 and other end labeled LVT-J10 to LVT ter-minal strip.

38AP025-060 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness andmake the wiring connections. See Fig. 9 for wiring.Install the new harness 38APHLSBCE-A00 provided.

1. Install plug labeled MBB-J3 to MBB-J3 and other end la-beled EMM-J4 to EMM-J4.

2. Install plug labeled MBB-J2 connector to MBB-J2 andother end labeled EMM-J1 to EMM-J1.

3. Install plugs labeled EMM-J6 and J7 to EMM-J6 and J7and other end labeled LVT-J10 to LVT terminal strip.

38AP065-130 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 10 for wiring.

1. Disconnect the CXB connector J4 and plug it into theEMM connector J3.

2. Install the new harness 38APHLSLCE-A00 provided.a. Install plug labeled CXB-J4 to CXB-J4 and other

end labeled EMM-J4 to EMM-J4.

b. Install plug labeled CXB-J2 connector to CXB-J2and other end labeled EMM-J1 to EMM-J1.

c. Install plugs labeled EMM-J6 and J7 to EMM-J6and J7 and other end labeled LVT-J10 to LVT ter-minal strip.

38AP065-130 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness andmake the wiring connections. See Fig. 10 for wiring.Install the new harness 38APHLSLCE-A00 provided.

1. Install plug labeled CXB-J4 to CXB-J4 and other end la-beled EMM-J4 to EMM-J4.

2. Install plug labeled CXB-J2 connector to CXB-J2 andother end labeled EMM-J1 to EMM-J1.

3. Install plugs labeled EMM-J6 and J7 to EMM- J6 and J7and other end labeled LVT-J10 to LVT terminal strip.

30RAP010-060 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 11 for wiring.

1. Disconnect the EXV connector J4 and plug it into theEMM connector J4.

2. Install the new harness 38APHSCALECA00. Install pluglabeled EXV-J4 to EXV-J4 and other end labeled EMM-J3 to EMM-J3.

3. Install the new harness 38APHSCALECA10. DisconnectMBB connector J2 and plug it into the EMM-J2. Installplug labeled MBB/EXV-J2 to MBB-J2 and other end la-beled EMM-J1 to EMM-J1.

4. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and other endlabeled LVT-J10 to LVT terminal strip.

5. Install the new harness 38APHSCALXCA00 provided.Install plug labeled EMM-J3 to EMM-J3 and other endlabeled AUX-J9 to AUX-J9.

DISCONNECTOPTION CB1A/TB1A

TRAN1

FB1

CA1 CA2 CA3

CSB-A1 CSB-A2 CSB-A3

CCB-1 CCB-2 CCB-3

CCH

MBB

EMM

LVT

UPCUPC LONOPTIONTB3

OFF

ON

SW2

ENABLE

SW1

REMOTECONTROL

CB1 CB2 CB3

LOCATED OVER EMM

OFF

L1 L2 L3

12345678910111213141516171819202122232425

EQUIPGND

2 4 6

Fig. 8 — Mounting EMM — 30MP015-45 Units

LEGEND

CB — Circuit BreakerCCB — Compressor Circuit BreakerEMM — Energy Management ModuleEQUIP — EquipmentFB — Fuse BlockGND — GroundLVT — Low Voltage TerminalMBB — Main Base BoardTB — Terminal BlockTRAN — Transformer

Terminal Block Connection

a38-7210

6

30RAP010-060 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness andmake the wiring connections. See Fig. 11 for wiring.

1. Install the new harness 38APHSCALECA00. Installplug labeled EXV-J4 to EXV-J4 and other end labeledEMM-J3 to EMM-J3.

2. Install the new harness 38APHSCALECA10. Install pluglabeled MBB/EXV-J2 to MBB-J2 and other end labeledEMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and other endlabeled LVT-J10 to LVT terminal strip.

30RAP070-150 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 12 for wiring.

1. Disconnect the CXB connector J4 and plug it into theEMM connector J4.

2. Install the new harness 38APHSCALECA00. Install pluglabeled EXV-J4 to CXB-J4 and other end labeled EMM-J3 to EMM-J3.

3. Install the new harness 38APHSCALECA10. Install pluglabeled MBB/EXV-J2 to CXB-J2 and other end labeledEMM-J1 to EMM-J1.

4. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and other endlabeled LVT-J10 to LVT terminal strip.

30RAP070-090 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness andmake the wiring connections. See Fig. 11 for wiring.

1. Install the new harness 38APHSCALECA00. Install theplug labeled EXV-J4 to CXB-J4 and other end labeledEMM-J3 to EMM-J3.

2. Install the new harness 38APHSCALECA10. Install pluglabeled MBB/EXV-J2 to CXB-J2 and other end labeledEMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and other endlabeled LVT-J10 to LVT terminal strip.

30MP015-045 UNITS WITH AUX BOARD — Performthe following procedure to install the harness and make thewiring connections. See Fig. 13 for wiring.

1. Disconnect the MBB connector J3 and plug it into theEMM connector J3.

2. Install the new harness 38APHSCALECA00. Install oneend of the harness in MBB connector J3 and the other endin EMM connector J4.

3. Install the new harness 38APHSCALECA10. Install pluglabeled MBB/EXV-J2 to MBB-J2 and other end labeledEMM-J1 to EMM-J1.

4. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and the otherend labeled LVT-J10 to J10 of the LVT terminal strip.

5. Install the new harness 38APHSCALXCA00 provided.Install plug labeled EMM-J3 to EMM-J3 and other endlabeled AUX-J9 to AUX-J9.

30MP015-045 UNITS WITHOUT AUX BOARD — Per-form the following procedure to install the harness andmake the wiring connections. See Fig. 13 for wiring.

1. Install the new harness 38APHSCALECA00. Installone end of the harness in MBB connector J3 and theother end in EMM connector J4.

2. Install the new harness 38APHSCALECA10. Install pluglabeled MBB/EXV-J2 to MBB-J2 and other end labeledEMM-J1 to EMM-J1.

3. Install the new harness 38APHSCALE-A00. Install plugslabeled EMM-J6 and J7 to EMM-J6 and J7 and the otherend labeled LVT-J10 to J10 of the LVT terminal strip.

FIELD WIRING CONNECTIONS — Refer to Fig. 9-13for field wiring interfaces with the LVT terminal strip.

Controls Configuration for EMM Options —Refer to the 38AP controls and troubleshooting manual forsplit system configuration of controls. Refer to the 30RAPcontrols and troubleshooting manual for Aquasnap® configu-ration of controls. Refer to the 30MP controls and trouble-shooting manual for configuration of controls.

7

FIOP/

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

3

2

1

3

2

1

6

5

4

3

2

1

J9

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

LVT

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DEMANDLIMITSTEP 1OR Y3

DEMANDLIMITSTEP 2OR Y4

DGS ORMM

FIOP

DUS

2

1

8

7

2

1

8

7

J2

J6DTT

VIO

BRN

RED

BLK

2

12

1RED

BLKJ4

CH1

-

CH11

-

CH9

-

2

12

1

J5CH10

-

TO MM-A

J10

AUX

LEGEND

Fig. 9 — Typical Wiring Connections (38AP025-060 Units)

EMM — Energy Management Module MBB — Main Base BoardFIOP — Factory-Installed Option Field WiringLVT — Low Voltage Terminal

a30-4943

A38-7212

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

24-V POWER CONNECTION

8

FIOP/

12

11

10

9

8

7

6

5

4

3

2

1

6

5

4

3

2

1J5

CXB4

3

2

1

4

3

2

1

J3

CSBB3

2

3

1

RED

ORN

BRN

CSBA3

2

3

1

RED

ORN

BRN

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

DUS

3

2

1

3

2

1

6

5

4

3

2

1

J9 2

1

8

7

2

1

8

7

J2

J6DTT

RED

WHT

BLK

DGS ORMM

FIOP

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

LVT

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DEMANDLIMITSTEP 1OR Y3

DEMANDLIMITSTEP 2OR Y4

VIO REDPL50-1

BRN BLK

PL50-2

RED REDPL50-3

BLK BLK

PL50-4

2

12

1RED

BLKJ4

CH1

-

CH11

-

CH9

-

-

+

G

-

+

G

2

12

1RED

BLKJ5CH10

-

TO MM-A

TO MM-B

(090-130 ONLY)

J10

AUX

LEGEND

Fig. 10 — Typical Wiring Connections (38AP065-130 Units)

CXB — Compressor Expansion Board MBB — Main Base BoardEMM — Energy Management Module Field WiringFIOP — Factory-Installed Option

a30-4944

A38-7212

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

24-V POWER CONNECTION

9

FIOP/

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

1

1

2

3

4

5

6

1

2

3

4

5

6

10

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mAPNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

14

15

4

3

12

13

6

5

11

RED

RED

BLU

BLUDLS STEP 2

DLS STEP 1

LVT

16

17

2

1GRA

GRAICE DONE

J10

Fig. 11 — Typical Wiring Connections (30RAP010-060 Units)

a30-4945

A38-7212

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

24-V POWER CONNECTION

Fig. 12 — Typical Wiring Connections (30RAP070-150 Units)LEGEND FOR FIG. 11 AND 12

CXB — Compressor Expansion Board LVT — Low Voltage TerminalEMM — Energy Management Module MBB — Main Base BoardFIOP — Factory-Installed Option Field Wiring

10

Fig. 13 — Typical Wiring Connections (30MP015-45 Units)

MAINBASEBOARD

FIOP/

ON

OFF

1 2 3 4 5 6 7 8DARK = SWITCH LOCATION

DUS

3

2

1

3

2

1

6

5

4

3

2

1

J9

2

1

8

7

2

1

8

7

J2

J6DTTRED

WHT

BLK

DGS

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7

J7

EMM4

3

2

1

4

3

2

1

J3

4

3

2

1

4

3

2

1

J4

RED

WHT

BLK

RED

WHT

BLK

12

11

10

9

8

7

6

5

4

3

2

1

12

11

10

9

8

7J6

14

1314

13

ACCESSORY

1

1

2

3

4

5

6

1

2

3

4

5

6

14

15

4

3

12

13

6

5

10

11

7

8

9

8

6

7

4

5 9

2

3

10 +

-

COOLINGSETPOINT4-20mA

RED

RED

BLU

BLU

PNK

ORN

BRN

VIO

+

-

TEMPRESET4-20mA

+

-

DEMANDLIMIT4-20mA

DLS STEP 2

VIO

BRN

RED

BLK

CH1

-

CH11

-

-

+

G

-

+

G

DLS STEP 1

LVT

16

17

2

1GRA

GRAICE DONE

3

44

32

21

1

BLK

WHT

RED

J3

FIOP

J10

AUX2

LEGENDEMM — Energy Management Module MBB — Main Base BoardFIOP — Factory-Installed Option Field WiringLVT — Low Voltage Terminal

A38-7212

A38-7211

33

22

11

J2BRN

VIO

22

1

J1

1

33

MBB BRN

RED

33

22

11

J22

J1

1

3

FIOP/ACCESSORY

EMM

24-V POWER CONNECTION

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53300104-01 Printed in U.S.A. Form 30/38-11SI Pg 12 11-12 Replaces: 30/38-7SI

© Carrier Corporation 2012