1 7019-230H January 4, 2018 SANTA FE PELLET INSERT APPLIANCE Model: SANTAFEI-MBK Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL WARNING If the information in these instruc- tions is not followed exactly, a fire could result causing property damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • Do not over fire - If appliance or chimney connector glows, you are over firing. Over firing will void your warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace. Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. WARNING CAUTION Tested and approved for wood pellets and corn pellets. Burning of any other type of fuel voids your warranty. NOTE To obtain a French translation of this manual, please contact your dealer or visit www.quadrafire.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafire.com CAUTION Check building codes prior to installation. Installation MUST comply with local, regional, state and na- tional codes and regulations. Consult local building, fire officials or authorities having juris- diction about restrictions, installation inspection, and permits. Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.

Upload: truongtu

Post on 08-Mar-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

1 7019-230H January 4, 2018

SANTA FE PELLET INSERT APPLIANCE

Model: SANTAFEI-MBK

Installation ManualInstallation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.

NOTICE: DO NOT DISCARD THIS MANUAL

WARNING

If the information in these instruc-tions is not followed exactly, a fire could result causing property damage, personal injury, or death.

• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.

• Donotoverfire-Ifapplianceorchimneyconnectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.

• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.

HOT SURFACES! Glassandothersurfacesarehot duringoperationANDcooldown.

Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLY SUPERVISE children in same room as

fireplace.• Alertchildrenandadultstohazardsofhightemperatures• High temperatures may ignite clothing or other

flammable materials.• Keep clothing, furniture, draperies andother flammable

materialsaway.

WARNING

CAUTIONTestedandapprovedforwoodpelletsandcornpellets.Burningofanyothertypeoffuelvoidsyourwarranty.

NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyourdealerorvisitwww.quadrafire.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaîtcontactervotrerevendeurouvisitezwww.quadrafire.com

CAUTIONCheckbuildingcodespriortoinstallation.• InstallationMUSTcomplywithlocal,regional,stateandna-

tionalcodesandregulations.• Consultlocalbuilding,fireofficialsorauthoritieshavingjuris-

dictionaboutrestrictions,installationinspection,andpermits.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.

Page 2: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

2 7019-230H January 4, 2018

SANTA FE PELLET INSERT

TABLE OF CONTENTS

Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.

1 Important Safety Information ............3A.ApplianceCertification.......................................................3B.BTU&EfficiencySpecifications.........................................3C.GlassSpecifications..........................................................3D.ElectricalRating.................................................................3E.MobileHomeApproved..................................................... 3

2 Getting Started ...................................4A.Design,Installation&LocationConsiderations..........................4B.ThermostatWallControlLocation......................................5C.ToolsAndSuppliesNeeded...............................................5D.InspectApplianceandComponents.................................5E.InstallChecklist..................................................................6

3 Dimensions and Clearances .............7A.ApplianceDimensions.......................................................7B.ClearanceToCombustibles,ULandULC.........................8C.MinimumOpeningforMasonry& ZeroClearanceFireplaces................................................9D.HearthExtension...............................................................9E.FloorProtection.................................................................9F.InstallationintoaFactory-BuiltFireplace...........................10G.InstallationintoaMasonryFireplace.................................11H.PrefabricatedMetalChimney............................................11

4 Vent Information ...............................12A.VentingTerminationMinimumRequirements....................12B.AvoidingSmokeandOdors...............................................13C.NegativePressure.............................................................14D.Draft..................................................................................14E.ChimneyandExhaustConnection...................................14F.EquivalentFeetofPipe.....................................................15G.PipeSelectionChart.........................................................15

5 Venting Systems ..............................16A.FullRelineWithOutsideAir-Horizontal............................16B.FullRelineWithOutsideAir-Vertical...............................17

6 Appliance Set-Up .............................18A.LevelingSystem................................................................18B.OutsideAirKitInstructions.................................................18C.OptionalGrilleRemovalandInstallation...........................19D.DoorHandleRemoval.......................................................19E.DoorRemoval....................................................................19F.AdjustableHearthSupport................................................20G.PanelandTrimSet............................................................21H.ThermostatInstallation...................................................... 22I.ThermostatOperation.........................................................23J.OptionalLogSetPlacement..............................................23

7 Mobile Home Installation .................248 Reference Materials .........................25

A.Service&MaintenanceList...............................................25B.AccessoryList....................................................................27

Page 3: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 3

SANTA FE PELLET INSERT

Model SantaFePelletInsertLaboratory OMNITestLaboratories,Inc.Report No. 061-S-77d-6.2Type SolidFuelRoomAppliance/PelletFuel

BurningTypeInsertStandard ASTME1509-2004,ULCS628-93and

ULC/ORD-C1482-M1990RoomAppli-ancePelletFuelBurningTypeand(UM)84-HUD,MobileHomeApproved

FCC ComplieswithPart15ofFCCRules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.

TheQuadra-FireSanta FePellet Insertmeets theU.S.EnvironmentalProtectionAgency’semissionlimitsforpelletinsertssoldafterMay15,2015.This pellet insert needsperiodic inspectionand repair forproperoperation.Itisagainstfederalregulationstooperatethis pellet insert in amanner inconsistentwith operatinginstructionsinthismanual.B. BTU & Efficiency Specifications

EPACertification#: 940-14EPACertifiedEmissions: 1.8gramsperhour*LHVTestedEfficiency: N/A**HHVTestedEfficiency: N/A

***EPABTUOutput: 8,500to28,200/hr.****BTUInput: 11,600to38,700/hr.

VentSize: 3or4inches,“L”or“PL”HopperCapacity: 45lbs.

Fuel WoodPellets*WeightedaverageLHVefficiencyusingdatacollectedduringEPAemissionstest.**WeightedaverageHHVefficiencyusingdatacollectedduringEPAemissionstest.***ArangeofBTUoutputsbasedonEPADefaultEfficiencyandtheburnratesfromthelowandhighEPAtests.****Based on the maximum feed rate per hour multiplied byapproximately8600BTU’swhich is theaverageBTU’s fromapoundofpellets.

1 Important Safety Information

NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.

Improper installation, adjustment, alteration, service ormaintenancecancauseinjuryorpropertydamage.Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.

Quadra-FireisaregisteredtrademarkofHearth&HomeTechnologies.

• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• Installation other than as instructed by Hearth & Home

Technologies.• Installationand/oruseofanycomponentpartnotapprovedby

Hearth&HomeTechnologies.• Operatingappliancewithoutfullyassemblingallcomponents.• Operating appliancewithout legs attached (if suppliedwith

appliance).• DoNOTOverfire-Ifapplianceorchimneyconnectorglows,

youareoverfiring.Anysuchactionthatmaycauseafirehazard.

WARNING

Fire Risk.Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

C. Glass SpecificationsThisapplianceisequippedwith5mmceramicglass.Replaceglassonlywith5mmceramicglass.Pleasecon-tactyourdealerforreplacementglass.D. Electrical Rating115VAC,60Hz,Start4.1Amps,Run1.1Amps

E. Mobile Home Approved • Thisapplianceisapprovedformobilehomeinstalla-

tionswhennotinstalledinasleepingroomandwhenanoutsidecombustionairinletisprovided.

• Thestructuralintegrityofthemobilehomefloor,ceil-ing,andwallsmustbemaintained.

• The appliance must be properly grounded to theframeofthemobilehomeanduseonlyListedpelletventClass“L”or“PL”connectorpipe.

• OutsideAirKit,partOAK-ACCmustbeinstalledinamobilehomeinstallation.NOTE: Thisinstallationmustconformwithlocalcodes.In

theabsenceoflocalcodesyoumustcomplywiththeASTM E1509-2004, ULC S628-93, ULC/ORD-C-1482-M1990, (UM) 84-HUD

A. Appliance Certification

Page 4: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

4 7019-230H January 4, 2018

SANTA FE PELLET INSERT

Install Guide2 Getting Started

Marginal Location:• Below peak

Location NOT recommended:• Not the highest point of the roof• Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended:Outside Air Intakeon windward side

NOT recommended:Outside Air Intakeon leeward side

Recommended Location:• Above peak

Recommended:• Insulated exterior chase

in cooler climates

Recommended Location:• Above peak• Inside heated space

Location NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wall

Marginal Location:• Wind loading possible

Figure 4.1

A. Design, Installation & Location Considerations 1. Appliance Location

NOTICE: Check building codes prior to installation.• InstallationMUSTcomplywithlocal,regional,stateand

nationalcodesandregulations.• Consult insurance carrier, local building inspector, fire

officialsorauthoritieshavingjurisdictionoverrestrictions,installationinspectionandpermits.

Itisagoodideatoplanyourinstallationonpaper,usingexactmeasurements for clearances and floor protection, beforeactuallybeginningtheinstallation.Locationoftheapplianceandchimneywillaffectperformance.Considerationmustbegivento:• Safety,convenience,trafficflow• Placementofthechimneyandchimneyconnectorandto

minimizetheuseofchimneyoffsets. • Placetheappliancewheretherewillbeaclearpassage

foraListedchimneythroughtheceilingandroof(vertical)orthroughexteriorwall(horizontal).

• Installingtherequiredoutsideairkitwillaffectthelocationoftheventtermination.

Whenlocatingventandventingtermination,theidealloca-tionistoventaboverooflinewhenpossible.Thisminimizestheaffectsofwindloading.

Sincepelletexhaust cancontainash, sootor sparks, youmustconsiderthelocationof:• Windows• AirIntakes• AirConditioner• Overhang,soffits,porchroofs,adjacentwalls• Landscaping,vegetation• Horizontalorverticalventtermination

2. Floor SupportThe supporting floor under the appliancemust be able tohandletheweightoftheappliance,fuelloadandtheweightofthechimney.Ensure that your floor will support these weights prior toinstallation. Add sufficient additional support tomeet thisweight requirementprior to installation. Theweightof theapplianceis214lbs.

CAUTIONIfburningshelledfieldcorn,youmustuseapprovedventingspecif-icallydesignedforcorntopreventcorrosionordegradation.Followtheinstructionsfromtheventingmanufacturer.

Page 5: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 5

SANTA FE PELLET INSERT

WARNINGHearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

•Installationanduseofanydamagedappliance.•Modificationoftheappliance.• InstallationotherthanasinstructedbyHearth&HomeTechnologies.

• Installation and/or use of any component part notapprovedbyHearth&HomeTechnologies.

• Operating appliance without fully assembling allcomponents.

• Operatingappliancewithout legsattached (ifsuppliedwithappliance).

• DoNOTOverfireOr any such action that may cause a fire hazard.

ReciprocatingSaw ChannelLocksHammer PhillipsScrewdriverTapeMeasure PlumbLine1/4”Self-TappingScrews FramingMaterialHi-tempCaulkingMaterial GlovesSafetyGlasses FramingSquareElectricDrill&Bits(1/4”) Level

Mayalsoneed:VentSupportStraps VentingPaint

Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace:

C. Tools And Supplies Needed

B. Thermostat Wall Control LocationThe thermostatwallcontrol’slocationwillhavesomeaffecton the appliance’soperation.• Maximumwirelengthfromapplianceis100feet(30.48m)

continuousnon-splicedwire. Recommended20gaugewire,solidcopper.

• When located close to the appliance, itmay require aslightlyhighertemperaturesettingtokeeptherestofthehousecomfortable.

• Whenlocatedinanadjacentroomoronadifferentfloorlevel,youwillnoticehighertemperatures near the appli-ance.

D. Inspect Appliance and Components • Opentheapplianceandremoveallthepartsandarticles

packedinsidetheComponentPack.Inspectallthepartsandglassforshippingdamage.

• Reporttoyourdealeranypartsdamagedinshipment.

• Alllabelshavebeenremovedfromtheglassdoor.

• Platedsurfaceshavebeenwipedcleanwithasoftcloth,ifapplicable.

• Read all the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

• Follow pipe manufacturer instructions for installation and air clearance requirements.

WARNINGFire Risk.

Damagedpartscouldimpairsafeoperation.DoNOT installdamaged, incompleteorsubstitutecomponents.

Page 6: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

6 7019-230H January 4, 2018

SANTA FE PELLET INSERT

E. Install Checklist

Appliance Install

Appliance is leveled and connector is secured to appliance.Hearth extension size/height decided. Outside air kit installed.Floor protection requirements have been met.If appliance is connected to a masonry chimney, it should be cleaned and inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and clearances.

Chimney

Chimney installed, locked and secured in place with proper clearance. Chimney meets recommended height requirements (14-16 feet).

Terminations installed and sealed.

ClearancesCombustible materials not installed in non-combustible areas.

Mantels and wall projections comply with installation manual requirements. Protective hearth strips and hearth extension installed per manual requirements.

Appliance SetupAll packaging and protective materials removed.

All labels have been removed from the door.All packaging materials are removed from inside/under the appliance.Manual bag and all of its contents are removed from inside/under the appliance and given to the party responsible for use and operation.

ATTENTION INSTALLER:Follow this Standard Work Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.

Customer: __________________________________________________________________________Date Installed: __________________________________________________________________________Lot/Address: __________________________________________________________________________Location of Appliance: ______________________________________________________________Installer: __________________________________________________________________________Dealer/ Distributor Phone #: ______________________________________________________________Serial #: __________________________________________________________________________Model : __________________________________________________________________________

WARNING! Risk of Fire or Explosion!

Hearth & Home Technologies recommends the following:

• That this checklist remain visible at all times on the appliance until the installation is complete.

Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:Comments communicated to party responsible by on (Builder/Gen. Contractor) (Installer) (Date)

YES IF NO, WHY?

Page 7: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 7

SANTA FE PELLET INSERT

Figure 7.2- Front View with small basic panel set

Figure 7.1 - Top View Figure 7.3 -Side View

8 in[203mm]

28-7/8 in [732mm]

23-5/8 in [600mm]

9-5/8 in[246mm]

11-1/8 in[283mm]

21-1/2 in [546mm]

12-3/4 in[325mm]

9-1/2 in[243mm]

30 in[762mm]

40 in [1016mm]

14-5/8 in [373mm]

9-7/8 in[250mm]

Figure 7.4- Front View with large basic panel set

50 in [1270mm]50 in [1270mm]

33 in[838mm]

25-3/8 in[644mm]

8-5/8 in[221mm]

12-3/4 in[325mm]

23 in[584mm]

17-7/8 in[453mm]

3 Dimensions and ClearancesA. Appliance Dimensions

Page 8: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

8 7019-230H January 4, 2018

SANTA FE PELLET INSERT

B. Clearance To Combustibles, UL and ULC

NOTE:• IllustrationsreflecttypicalinstallationsandareFOR

DESIGNPURPOSESONLY.• Illustrations/diagramsarenotdrawntoscale.• Actualinstallationmayvaryduetoindividualdesign

preference.

FireRisk.Complywithallminimumclearancestocombusti-blesasspecified.

WARNING

Failuretocomplymaycausehousefire.

Figure 8.1

Be sure to follow vent manufacturers clearance to combustibles.

*If interior of chase will be drywalled, add the thickness to this measurement.

**From finished floor protection. The size of your floor protector choice must be added to this dimension.

25 in.**(635mm)25 in.**

(635mm)

32-7/8 in.(835mm)

15-1/4 in.*(387mm)

Page 9: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 9

SANTA FE PELLET INSERT

CD

A

B

C. Minimum Opening for Masonry & Zero Clearance Fireplaces

Figure 9.1

Figure 9.2

SID

E T

RIM

HEARTHEXTENSION

29-3/4 in(1010mm)

SID

E W

ALL

TOP TRIM

26-3/4 in(679mm)

20-3/4 in(527mm)

16 in(406mm)

Figure 9.3

FIRE

PLAC

E F

RON

T SU

RFAC

E

MANTEL

USA 12-1/2 in CANADA 12-1/2 po

(317mm)

37-3/8 in(975mm)

12 inmax * Note:Minimumopeningdimensionsincludea1/4”(6mm)

clearancearoundunit.

Note:Iftrimmeasurementisover3/4in(19mm)indepthusemantleorsideclearancestocombustibles.

NOTEItisnecessarytopermanentlysealanyopeningbetweenthemasonryofthefireplaceandthefacingmasonry.

Location Inches MillimetersA Height 23-1/4 591B FrontWidth 29-1/8 740C RearWidth 23-7/8 606D Depth 13 330

D. Hearth Extension

E. Floor Protection

Useanon-combustibleemberfloorprotector,extendingbeneaththeapplianceandtothefront,andtothesidesasindicatedinsub-sectionE.FloorProtection.

Figure 9.4

D

B

Page 10: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

10 7019-230H January 4, 2018

SANTA FE PELLET INSERT

Mark area offloor to cut

Starter hole

Keep sharp edge of metal floor away from power cord

F. Installation into a Factory-Built FireplaceThefollowingmodificationsarepermissible: • Removalofdamperorlockedinopenposition • Removalofsmokeshelforbaffle • Removalofembercatches • Removaloffiregrate • Removalofviewscreen/curtain • Removalofdoors

• Removaloffactory-builtfireplacefloor• Externaltrimpieceswhichdonotaffecttheoperationof

thefireplacemayberemovedprovidingtheycanbestoredonorwithin thefireplaceforreassembly if the insert isremoved.

• Thepermanentmetalwarning label providedmust beattached to the back of the fireplace,with screws ornails,statingthatthefireplacemayhavebeenalteredtoaccommodatetheinsert,andmustbereturnedtooriginalconditionforuseasaconventionalfireplace.Figure 10.1

Figure 10.2.Measure andmark themetalfloorforcutting.Withadrill,makeastarterholeineachcorner.

Figure 10.3. Usinga saws-all, cut out thefloor.

Figure 10.4.Placetheinsertintothefacto-ry-builtfirebox.Ensurethatthepowercordcan not be damaged by the sharp metaledge. Youmayneed tocutoutanotch toaccommodatethecord.

250-2061

WARNINGTHIS FIREPLACE MAY HAVE BEEN ALTEREDTO ACCOMMODATE AN INSERT. IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE. 250-2061

Heath & Home Technologies250-2061 5.5 in. width x 2 in. heightNON. ANOD. ALUM BLACK LETTERS ON SILVERwith 1/8 in. holes on both sides.Black letters

Figure 10.1

• Ifthehearthextensionislowerthanthefireplaceopening,theportionoftheinsertextendingontothehearthmustbesupported.

• Manufacturer designed adjustable support kit can beorderedfromyourdealer.

NOTE: Refer to chimney liner manufacturer for recom-mendations on supporting the liner. Installation into fireplaces without a permit will void the listing.•

• The firebrick (refractory), glass doors, screen rails,screenmeshandloggratescanberemovedfromafac-tory-builtfireboxinordertogainminimuminsertopen-ingrequirements.

• Anysmokeshelves,shieldsandbafflesmayberemovedfromafactory-builtfirebox ifattachedwithmechanicalfasteners.

• The metal floor of the factory-built firebox may beremoved to facilitate the installation of the insert onlywhena1inch(25mm)airspaceisprovidedbetweentheinsertandthefloorofouterwrap.

Thefollowingisonlyoneexampleastherearemanydiffer-entmodelsoffactory-builtfireplaces.NOTE: This example is for reference only. Any modifica-

tions must not compromise the structural integrity or reduce the protection for combustible materials.

Page 11: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 11

SANTA FE PELLET INSERT

NOTICE: InCanadawhenusingafactory-builtchim-neyitmustbesafetylisted, Type UL103 HT (2100oF) [1149oC] CLASS “A” orconformingtoCAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.

H. Prefabricated Metal ChimneyThechimneycanbeneworexisting,masonryorprefabricatedandmustmeetthefollowingminimumrequirements: •Must beminimum6 inch (152mm) inside diameter of

hightemperaturechimneylistedtoUL103HT(2100oF)orULC-S628.

•Mustusecomponentsrequiredbythemanufacturerforinstallation.

•Mustmaintainclearancesrequiredbythemanufacturerforinstallation.

•Refertomanufacturersinstructionsforinstallation •This insert is listed toASTME1509-12Standardand

isapproved for installation into listed factory-builtzeroclearancefireplaces listed toUL127conforming to thefollowingspecificationsandinstructions:

•The original factory-built clearance fireplace chimneycap must be re-installed after installing the approvedchimney liner meeting type UL 103 HT requirements(2100°F)perUL1777.

•IfthechimneyisnotlistedasmeetingHTrequirements,orifthefactorybuiltfireplacewastestedpriorto1998,afullheightlistedchimneylinermustbeinstalledfromtheappliancefluecollartothechimneytop.

•Thelinermustbesecurelyattachedtotheinsertfluecollarandthechimneytop.

•Theairflowofthefactory-builtzero-clearancefireplacesystemmustnotbealtered.Theflue liner topsupportattachmentmustnotreducetheairflowfortheexistingair-cooledchimneysystem.

•Nodilutionairisallowedtoenterthechimney. 1.Securethefireplacedamperintheopenposition.If

thiscannotbeaccomplished,itwillbenecessarytoremovethedamper

2.Seal damper area of chimney around chimneyconnectorwithahigh temperaturesealantor sealinsertagainstthefaceofthefireplace.

3.Bothmethodsmustberemovableandreplaceableforcleaningandre-installation.

• Removingflooroffireplacemustnotweakenstructureoffireboxorreduceprotectionforcombustiblematerials.

• Finalapprovalofthisinstallationtypeiscontingentupontheappropriatelocalauthorityhavingjurisdiction.

WARNING

G. Installation into a Masonry FireplaceAllmodifications thatcanbemade toaFactoryBuiltFire-placecanbemadetoaMasonryFireplace.

Inaddition DO NOT removeanybrickormortar from theexistingfireplace.

Risk of Fire!Follow ventingmanufacturer’s clearances andinstructionswheninstallingventingsystem.

WARNING

Page 12: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

12 7019-230H January 4, 2018

SANTA FE PELLET INSERT

4 Vent InformationA. Venting Termination Minimum Requirements

J or KXV

MI

HAV

G

BV

V

A

B

V

F V

C

B

B

E

LV

D

V

ElectricalService

V

NV N

V

N

N

V

Inside Corner

FIXED CLOSEDOPEN

OPEN

FIXED CLOSED

V X

G

GTermination Cap Air Supply Inlet Gas Meter Restricted Area

O

P

Figure 12.1

A 12in. AboveFinishGrade(thegradesurfacemustbeanon-combustiblematerial

B 12in.48in.noOAK

Opendoororwindow:belowortotheside

B 12in. Opendoororwindow:above

C 6in. Permanentlyclosedwindow:above,belowortotheside

D 18in.36in.noOAK

Verticalclearancetoaventilatedsoffitlocatedabovetheterminalwithinahori-zontaldistanceof2ftfromthecenter-lineoftheterminal

E 12in. Clearancetounventilatedsoffit

F 12in. Clearancetooutsidecorner

G 12in. Clearancetoinsidecorner

H 36in. Abovegasmeter/regulatormeasuredfromhorizontalcenter-lineofregulator

I 36in.USA72in.Canada

Clearancetoserviceregulatorventoutlet

J 12in.48in.noOAK

Clearancetonon-mechanicalairsupplyinlettothebuildingorthecombustionsairinlettoanyotherappliance

K 10fthorizontal3ftvertical

Clearancetomechanicalairsupply

L 7ft. Abovepavedsidewalk,paveddrivewaylocatedonpublicproperty

M 12in. Underanopenveranda,porch,deckorbalcony

N SeeNotebelow*

Electricservice:above,belowortotheside(locationmustnotobstructorinterferewithaccess)

O 24in. Adjacentbuilding,fencesandprotrudingpartsofthestructure

P 12in. Clearanceaboverooflineforverticalterminations

All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.

24in. Abovegrass,topofplants,woodoranyothercom-bustible

12in.36in.noOAK

Clearancefromanyforcedairintakeofotherappli-ance

12in. Clearancehorizontallyfromcombustiblewall

15in. Venteddirectlythroughawall,minimumlengthofhorizontalpipe

6in.horizontal12in.vertical

Minimumhorizontalorverticalterminationsmustprotrudefromwall

*NOTE: Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdic-tion.Localcodesorregulationsmayrequiredifferentclearances.

NOTICE:Do NOT Terminate Vent:• Inanylocationthatwillallowfluegasesorsootfromen-

teringorstainingthebuilding• Inanylocationwhichcouldcreateanuisanceorhazard• Inanyenclosedorsemi-enclosedareasuchasacarport,

garage,attic, crawl space,underasundeckorporch,narrowwalkway

• Closely fencedarea, or any location that canbuild upa concentration of fumes such as a stairwell, coveredbreezeway,etc.

NOTICE:

Termination must exhaust above air inlet elevation.

• Itisrecommendedthatatleast60inches(1.52m)ofverticalpipebeinstalledwhenapplianceisventeddirectlythroughawall.Thiswillcreateanaturaldraft,whichwillhelppreventthepossibilityofsmokeorodorventingintothehomeduringapoweroutage.

• Itwillalsokeepexhaustfromcausinganuisanceorhazardbyexposingpeopleorshrubstohightemperatures.

• Thesafestandpreferredventingmethodistoextendtheventverticallythroughtherooforabovetheroof.

Page 13: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 13

SANTA FE PELLET INSERT

B. Avoiding Smoke and Odors

Negative Pressure, Shut-Down and Electrical Power Failure

To reduce the probability of back-drafting or burn-back inthepelletapplianceduringpowerfailureorshutdowncon-ditions, it must be able to draft naturally without exhaustbloweroperation.Negativepressureinthehousewillresistthisnaturaldraftifnotaccountedforinthepelletapplianceinstallation.

Heatrisesinthehouseandleaksoutatupperlevels.Thisairmustbereplacedwithcoldairfromoutdoorswhichflowsintolowerlevelsofthehouse.Ventsandchimneysintobasementsandlowerlevelsofthehousecanbecome the conduit for air supplyand reverseundertheseconditions.

Outside Air

Anoutsideairkit isrecommended inall installations. TheOutsideAirKitmustbeorderedseparately.Pernationalbuildingcodes,considerationmustbegiventocombustionairsupplytoallcombustionappliances.Failuretosupplyadequatecombustionairforallappliancedemandsmayleadtoback-draftingofthoseandotherappliances.

Whentheapplianceisroofvented(stronglyrecommended): Theairintakeisbestlocatedontheexteriorwallorientedtowardstheprevailingwinddirectionduringtheheatingseason.

Whentheapplianceisside-wallvented:Theairintakeisbestlocatedonthesameexteriorwallastheexhaustventoutletandlocatedloweronthewallthantheexhaustventoutlet.

Theoutsideairsupplykitcansupplymostofthedemandsofthepelletappliance,butconsiderationmustbegiventothetotalhousedemand.Housedemandmayconsumetheairneededfortheappli-ance. Itmaybenecessarytoaddadditionalventilationtothespaceinwhichthepelletapplianceislocated.ConsultwithyourlocalHVACprofessionaltodeterminetheventilationdemandsforyourhouse.

Vent ConfigurationsWheninstallingapelletappliancewithahorizontalventcon-figurationthefrequencyofpoweroutagesshouldbeconsid-ered:

• Poweroutagesduringoperationwillcausetheappliancetoimmediatelyturnoffandmaycreateconditionswheresmokewillbackdraftintothehouse.Inordertoreducethe likelihood of smoke back drafting into the houseduringapoweroutage,HearthandHomeTechnologiesstronglysuggests:

• Installingthepelletventingwithaminimumverticalrunof5feet(1.52m).

• Installing theoutsideairkitat least4 feet (1.22m)belowtheventtermination.

Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:

• Maintain specified clearances towindows, doors andairinlets,includingairconditioners.

• Vents should not be placed below ventilated soffits.Runtheventabovetheroof.

• Avoidventingintoalcovelocations. • Ventsshouldnotterminateunderoverhangs,decksor

ontocoveredporches. • Maintain minimum clearance of 12 inches (305mm)

from the vent termination to the exteriorwall. If youseedepositsdevelopingonthewall,youmayneedtoextendthisdistancetoaccommodateyourinstallationconditions.

CAUTION• DONOTCONNECTTHISApplianceTOACHIMNEYFLUE

SERVICINGANOTHERAPPLIANCE.

• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.

Page 14: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

14 7019-230H January 4, 2018

SANTA FE PELLET INSERT

C. Negative PressureNegativepressure results from the imbalanceof air avail-ablefortheappliancetooperateproperly.Itcanbestrongestinlowerlevelsofthehouse.

Causesinclude:

• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustion air requirements for furnaces, water

appliancesandothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessedlighting - Attichatch - Ductleaks

Tominimizetheeffectsofnegativeairpressure:• Installtheoutsideairkitwiththeintakefacingprevailing

windsduringtheheatingseason• Ensureadequateoutdoorairforallcombustionappliances

andexhaustequipment• Ensurefurnaceandairconditioningreturnventsarenot

locatedintheimmediatevicinityoftheappliance• Avoid installing theappliancenear doors,walkwaysor

smallisolatedspaces• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams

tapedorsealed

D. Draft Draftisthepressuredifferenceneededtoventanappli-ancesuccessfully.Whenanapplianceisdraftingsuc-cessfully,allcombustionbyproductsareexitingthehomethroughthechimney.

Installthroughthewarmairspaceenclosedbythebuild-ingenvelope.Thishelpstoproducemoredraft,especiallyduringlightinganddie-downofthefire.Considerationsforsuccessfuldraftinclude:• Preventingnegativepressure• Locationofapplianceandchimney

NOTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the chimney system caused by:• Inadequate draft due to environmental conditions• Down drafts• Tight sealing construction of the structure• Mechanical exhausting devices

E. Chimney and Exhaust Connection 1. Chimney & Connector:Use3or4inch(76-102mm)diameter

type“L”or“PL”ventingsystem.Itcanbeventedverticallyorhorizontally.

2. Mobile Home: ApprovedforallListedpelletvent.Ifusingthe3inch(76mm)verticalTopVentAdapterKitorthe3to6inch(76-152mm)TopVentOffsetAdapter, use Listed doublewallflueconnector.AQuadra-FireOutsideAirKitmustbeusedwithmanufacturedhomeinstallations.

3. Residential: The3inch(76mm)verticalTopVentAdapterKitandthe3to6inch(76-152mm)TopVentOffsetAdapteraretestedtouse24gaugesinglewallflueconnectororListeddoublewallflueconnector toClassAListedmetal chimneys,ormasonrychimneysmeetingInternationalResidentialCodestandardsforsolidfuelappliances.

4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

5. Secureexhaustventingsystem to theappliancewithat least3screws.Alsosecureallconnectorpipejointswithatleast3screwsthrougheachjoint.

6. DONOTINSTALLAFLUEDAMPERINTHEEXHAUSTVENT-INGSYSTEMOFTHISAppliance.

7. DONOTCONNECTTHISApplianceTOACHIMNEYFLUESERVINGANOTHERAPPLIANCE.

NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only).

NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instructions from the venting manufacturer.

WARNINGRisk of Asphyxiation! Negativepressurecancausespillageofcombustionfumesandsoot.

Page 15: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 15

SANTA FE PELLET INSERT

Fire Risk.• OnlyLISTEDventingcomponentsmaybeused.

• NOOTHERventcomponentsmaybeused.

• Substituteordamagedventcomponentsmayimpairsafeoperation.

WARNINGRISK OF INJURY OR PROPERTY DAMAGE!•Improperinstallation,adjustment,alteration,serviceormaintenancecancauseinjuryorpropertydamage.

•Refertotheowner’sinformationmanualprovidedwiththisappliance.

• Forassistanceoradditionalinformationconsultaqualifiedinstaller,serviceagencyoryourdealer.

WARNING

F. Equivalent Feet of Pipe

Thetablebelowcanhelpyoucalculatetheequivalentfeetofpipewhichisamethodusedtodeterminepelletventsize.Figure 15.1.

2 ft.

2 ft.

3 ft.

2 ft.

Example of 3 Elbow-Rear Vent Termination Calculation

Pellet Venting Component

# of Elbows

Feet of Pipe

Multiplied By

Equivalent Feet

ComponentsEquivalent Feet

90oElboworTee 3 X 5 1545oElbow X 3HorizontalPipe 7 X 1 7VerticalPipe 2 X 0.5 1

Total Equivalent Feet 23

Note:Thisisagenericexampleandisnotintendedtorepresentanyspecificfueltype.

VentsurfacesgetHOT,cancauseburnsiftouched.Non-combustibleshieldingorguardsmayberequired.

WARNING

Figure 15.2

3 in. or 4 in. (76mm or 102mm) Diameter Pipe

Equivalent Pipe Length In Feet

ALTITUDE IN THOUSANDS OF FEET

0

20

30

1 2 3 4 5 6 7 8 9 10

4 in. (102mm) Diameter Pipe Only

10

Example 1

Example 2

Example 1:Iftheequivalentlengthofpipeis23feet(7m)withaltitudeof8,000feet(2438m)youmustuse4inch(102mm)diametertype“L”or“PL”vent.Example 2:Iftheequivalentlengthofpipeis12feet(3.7m)withaltitudeof6,000feet(1829m)youmayuse3or4inch(76to102mm)diametertype“L”or“PL”vent.

G. Pipe Selection Chart

Thechartwillhelpyouindeterminingproperventingsizeaccordingtotheequivalentfeetofpipecalculatedpreviouslyandthealtitudeabovesealevelofthisinstallation.Figure 15.2

a. Locatethecalculatedequivalentfeetofpipeontheverticalleftsideofthechart.

b. Movetotherighthorizontallyonthechartuntilyoureachyouraltitudeabovesealevel.

c. If you fall below the diagonal line, 3 or 4 inch (76 to102mm)pipemaybeused.

d. Ifitisanywhereabovethediagonalline,a4inch(102mm)diameterpipeisrequired.

NOTICE: • A90°elbowis5timesasrestrictivetotheflowofexhaust

gasesunderpositivepressureas1foot(305mm)ofhori-zontalpipe.

• Afootofhorizontalpipeistwiceasrestrictiveasafootofverticalpipe.

Figure 15.1

Page 16: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

16 7019-230H January 4, 2018

SANTA FE PELLET INSERT

NOTE:InCanada,wherepassagethroughawallorpartitionofcombustibleconstructionisdesired,theinstallationshallconformtoCAN/CSA-B365.

Figure 15.1

Fire Risk.InspectionofChimney:• Masonrychimneymustbeingoodcondition.• MeetsminimumstandardofNFPA211• Factory-builtchimneymustbeaminimum6inch

(152mm)UL103HT.

WARNINGCAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage

NOTE:• IllustrationsreflecttypicalinstallationsandareFORDESIGN

PURPOSESONLY.• Illustrations/diagramsarenotdrawntoscale.• Actualinstallationmayvaryduetoindividualdesign

preference.

Optional Outside Air through Rear Wall (Horizontal)

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insu-lation such as fiberglass, mineral wool or ceramic.

Do not use high temperature caulking materials to seal any edge to prevent furture service-ability.

Figure 16.1

5 Venting Systems

A. Full Reline With Outside Air - Horizontal

Page 17: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 17

SANTA FE PELLET INSERT

B. Full Reline With Outside Air - Vertical

Figure 17.3

NOTE: Checkclearancescarefullyforthistypeofinstal-lationtoensureadequateroomforoutsideairventing.

Checkbuildingcodespriortoinstallation.• InstallationMUST complywith local, regional, state and

nationalcodesandregulations.• Consultlocalbuilding,fireofficialsorauthoritieshavingjuris-

dictionaboutrestrictions,installationinspection,andpermits.

CAUTION

Direct Connect

45 degree elbow

Side view of Santa Fe Insert with side panel removed.

Figure 17.1

Figure 17.2

NOTE: InCanada,onlyafullrelineisallowedperULCS628-93,ORDULCC1482-M1990.

NOTE: InCanadathisfireplaceinsertmustbeinstalledwithacontinuouschimney linerextending fromthefire-placeinserttothetopofthechimney.ThechimneylinermustconformtotheClass3requirementsofCAN/ULC-S635,StandardforLiningSystemsforExistingMasonryorFactory-BuiltChimneysandVents,orCAN/ULC-S640,StandardforLiningSystemsforNewMasonryChimneys.

Outside Air Termination

at Chimney Top

12” (305mm) min. below

12” (305mm) min. above

NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic.

Do not use high temperature caulk-ing materials to seal any edge to prevent future serviceability

Page 18: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

18 7019-230H January 4, 2018

SANTA FE PELLET INSERT

6 Appliance Set-Up

A. Leveling SystemThelevelingboltsarelocatedattherearoftheappliance.Toaccessthebolts,removethefrontaccesspanels.Reachinandturnthebolttothedesiredheighttoleveltheappliance.

B. Outside Air Kit InstructionsPartsIncludedinKit:1pieceof2inchx3ft.flexhose,2hoseclamps,1collarassembly,1terminationcapassem-bly,1trimring,fasteners.ToolsNeeded:Phillipsheadscrewdriver;wirecutters;holesaworjigsaw.

1. Measuredistancefromfloortoairventopeninginapplianceandmarklocationonwall.2. Usesawtocutopeninginwall.Cuta2-1/2to3inch(64-76mm)openingoninsidewallanda3to3-1/2inch(76-89mm)openingonoutsideofhouse.3. Usehoseclamptosecureflexpipetocollaras-sembly.4. Slidetrimringoverflexpipeandrunpipethroughwall.5. Attachhosetooutsideterminationcapwithsecondhoseclamp.6. Secureterminationcaptooutsidesurface.7. Securetrimringtointeriorwall.

CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• EnclosedspacesuchasanatticorgarageFigure 18.1

Leveling Bolt on Each Side

Figure 18.2

Attach Termination Cap to Exterior Wall

2 inch diameter Flex Pipe

Page 19: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 19

SANTA FE PELLET INSERT

Figure 19.1

Grille Bracket Cover (shipped flat from factory)

Finger bend into position after grilles are installed on appliance

Insert heat exchanger rods through holes on second grille.

Heat Exchanger Rods

Install bottom 3 grilles before installing single top grille

Install in flat position

Bend after grilles installed

C. Optional Grille Removal and InstallationIncluded in Kit: (4)lowergrilles;(3)uppergrilles,(1)uppergrille;(4)grillebracketcovers;fastenersTools Required: #2 Phillipsheadscrewdriver

1. Openthedoor.Removethetop2screwsoneachsideofuppergrilleandremovethesinglegrille.Removethebottom2screwsoneachsideandremovethe3grillesattachedtogether.

2. Removing the ash drawer before taking off the lowergrillewillmakethelowergrilleeasiertoremove.UsingaPhillipsheadscrewdriver,removethe2screwsoneachsideandpull forwardwithadownwardmotion toavoidcatchingthegrilleonthefirepotpullrod.NOTE: The plated grilles, Nickel, Black Nickel and Gold, have 4 black grille bracket covers to eliminate the brightness of the bracket plating. The bracket covers are shipped flat, installed on the grilles, and after the grilles are installed on the appliance they are then finger-bent into position.

4. Attachthe4grillebracketcoverstothelower4grillesandthetop3grilles.Slipthemetalstripsthroughthegrilleopeningsandsecuretogrillewithscrewsprovided.Donotfingerbendthecoverbracketsatthistime.

5. Securethelowergrilletotheappliancewith2screwsoneachside. Fingerbend thebracketcoversaround theplatedbrackets.

6. Theuppergrillehas2separateparts.Installthe3grillesattachedtogetherfirst.Anglethegrillesdownwardandinserttheheatexchangercleaningrodsthroughtheholesinthesecondgrilleandthentwistforwarduntilhorizon-tallylevel.Attachthegrillewithonlythebottom2screwsoneachsideofgrille.Donotfingerbendthecoverbrack-etsatthistime.

7. Positionthesingletopgrilleoverthe3alreadyinplace.Attachwithonescrewoneachsidethroughthetopgrilleandtheother3grillestosecuretoappliance.

8. Fingerbend thebracketcoverson theuppergrille intoplace.

9. Re-installtheashdrawer.

D. Door Handle RemovalTools Required: 5/32Allenwrench

1. Open thedoor. Usinga5/32Allenwrench, loosensetscrewbyacoupleofturns,butdonotremove.

2. Pushthepincompletelyoutandremovethehandle.3. Re-installinreverseorder.

E. Door Removal1. Remove thedoorhandleand face. Follow instructions

fromDabove.2. Thedoorcannowbeliftedoffthehinges.3. Re-installinreverseorder.

Page 20: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

20 7019-230H January 4, 2018

SANTA FE PELLET INSERT

F. Adjustable Hearth Support Size: 9”d x 45”w, 2” to 10” Height Adjustment

Included in Kit: (1)trimtop,(1)trimfront,(2)trimsides,double-sidedtape(alreadyinstalled)Tools Needed: Phillipsheadscrewdriver,sheetmetalshears,measuringtape,gloves

1. The 10 screws on each set of scissorswill already beloosewhenshipped.Figure 20.1.

2. Expand scissors to desired height. Tighten screws tohold in place using Phillips head screwdriver. Figure 20.2.

3. Measurefrontandsidetrimstorequiredheighttocoverscissorsandmarkpiecesforcutting.Cutexcessmate-rial fromtopof trimsedge,not bottom.Thisedgewillbe sharp;wear gloves to prevent injury to your hands. Figure 20.3.

4. Using sheet metal shears, cut trim along the markededge.Thecutedgefitsunderlipoftoptrim,soitallowsforsomevarianceinyourstraightedge.

5. Thedouble-sidedtapethatholdsfrontandsidetrimstoscissorshasapowerfulbondingadhesive.Adjustmentsareextremelydifficultoncetrimhasadheredtotape.Doadryrunfirstwithoutremovingpaperfromtape.

6. Placecutedgeoftrimundertoplipandintopositiononscissors.Placesidepiecesonfirstandthenfrontpiece.Thefrontpieceoverlapssidepieces.

7. Onceyouaresatisfiedwiththepositioning,removetrimandsetaside.

8. Remove the paper from double-sided tape that is toaccepttrimside.Alignsideandthenpresshardagainsttapetosecuresidepiece.Repeatforotherside.Installfronttrimpiecelast.

9. Thereare3holesinthebackflangeofthetoptosecureittothewallifnecessary.Usetheappropriatefastenerforthetypeofwallmaterial,i.e.,brick,sheetrock,etc.

NOTE:3/8inch(9.5mm)thicktileorlikematerialcanbecuttosizeandfitunderlipoftoptrimedgeforadecora-tivetouch. Figure 19.3.

Figure 20.1

Figure 20.2

Figure 20.3

Figure 20.4

WARNINGSheetmetaltrimedgeswillbesharp.Forsafetypurposesweargloves.Injurycanoccur.

DOUBLE-SIDED TAPE DOUBLE-SIDED TAPE

SCREWS ARE CIRCLED

EXPLODED VIEW OF SCISSORS

Decorative tile may be installed

INSTALL FRONT TRIM LAST.CORNERS OVERLAP SIDE

TRIM PIECES

EXPAND SCISSORS TO DESIRED HEIGHT

CUT TOP EDGE OF TRIM, NOT BOTTOM EDGE

Page 21: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 21

SANTA FE PELLET INSERT

Access Panels

Open Hopper Lid for Easier Placement of Panel Set

Magnet

Hook

Figure 21.4

Figure 21.2

Figure 21.3

Figure 21.1- Completed View

G. Panel and Trim Set1. Laypaneltopandlegsfacedownonprotectivecovering

topreventscratching.

1. Attach the panel legs to the top panel using a Phillipshead screwdriver. There are 2 screws for each leg.Figure 21.2.

2. Openthehopperlidbypullingtowardyou.Thiswillmakeiteasiertosetthepanelsinplace.Securethepanelstotheinsert,2screwsperleg,asshowninFigure 21.3.

3. Connectthetrimpiecestogetherusingthe“L”Bracketssupplied.Figure 21.4.

4. Slidethetrimoverthetopofthepanels.

5. Install theaccesspanels. At thebottomof theaccesspanelthereare2hooksthatslipintoaslotatthebottomofthesidepanelandamagnetatthetopthatholdstheaccesspanelinplace.Figure 21.3.

Attach panellegs to top

Back view of panel

Access Panel

SidePanel

Page 22: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

22 7019-230H January 4, 2018

SANTA FE PELLET INSERT

Figure 22.1

Shockhazard.• DoNOTremovegroundingprongfromplug.• Plugdirectlyintoproperlygrounded3prong

receptacle.• Routecordawayfromappliance.• DoNOTroutecordunderorinfrontofappliance.

CAUTION

Junction Box

Cut Away

LEFT SIDE

Junction Box, Front

Power Cord Recepticle

Terminal Block Center 2 Screws for Thermostat wires or remote

110 Outlet for Remote Control Only (unfused)

Fuse Red Call Light

The 110 outlet on the junction box is for a remote con-trol ONLY. Do not use outlet for any other purpose. It can damage the appliance and it will void your war-ranty.

CAUTION

H. Thermostat Installation Thereisa4screwterminalblocklocatedonthejunction

boxtotherightofthepowercordinlet. Thecenter2screwsareforthethermostatwires.Theouter2arethemountingscrewsfortheterminalblock.Figure 22.1.

Theappliancecomesstandardwithawallthermostatand25’ofwire.Ifyouneedtorunmorethan25’makesureyouuseacontinuousstrandof18to22gaugethermostatwire.Foroptimumperformanceyourthermostatshouldbelocatedonaninsidewallapproximately5’upfromthefloor.

How to Install Your Wall Thermostat 1. Separatethebodyofthethermostatfromthemounting

platebygentlypullingthetwopiecesapart2. ConnectyourthermostatwiretotheWandRterminals

(seeFigure 22.2)3. Screwthebackerplatetothewallusingthehardware

included4. Snapthethermostattothebackerplate5. Connectthewirestothe2centerscrewsontheterminal

blockonthebackoftheproduct

Battery Installation and Replacement

NOTE: 2AAAbatteriesareincludedwiththethermostatandmustbeinstalledbeforetheappliancecanbeoper-ated.

InstallfreshbatteriesimmediatelywhentheREPLACE BATTERY warningbeginsflashing.Thewarningflashesabouttwomonthsbeforethebatteriesaredepleted.Evenifthewarningdoesnotappear,youshouldreplacebatteriesonceayear(seeFigure 23.1).Ifbatteriesareinsertedwithintwominutes,thetimeanddaywillnothavetobereset.Allothersettingsareperma-nentlystoredinmemory.

W RFigure 22.2

Page 23: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 23

SANTA FE PELLET INSERT

Figure 23.3

Figure 23.4

J. Optional Log Set Placement Two Piece Log Set Installation1. Opendoortoexposethefirebox.2. Install the left log firstandthentherightlog.Figure 23.33. Leanthelogsagainstthecastironbrickinthebackof

thefirebox.4. Pushthelogstothefarleftandfarrightagainstthesides

ofthefirebox.Figure 23.4.5. Tocleanthelogs,useavacuumcleanerandasoftbrush

attachmentorapaintbrush.

CAUTIONLogsareFRAGILE.Useextremecarewhenhandlingorcleaninglogs.

NOTE: Due to the abrasive nature of a pellet appliance fire, thelogsarenotcoveredunderwarranty.Anyplacementvari-ationotherthanshownherecancauseexcessiveheatandshallvoidtheappliancewarranty.

Figure 23.1

I. Thermostat Operation

Press and pull to removePress and pull to remove

Digital displayDigital display

Back light

Heat (On) or Off button

Temperature buttonsPress up or down to set preferred temperature.

Figure 23.2

Page 24: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

24 7019-230H January 4, 2018

SANTA FE PELLET INSERT

7 Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for installation in a mobile home.1. Anoutsideairinletmustbeprovidedforthecombustionairand

mustremainclearofleaves,debris,iceand/orsnow.Itmustbeunrestrictedwhiletheapplianceisinusetopreventroomairstarvationwhichcausessmokespillage.Smokespillagecanalsosetoffsmokealarms.

2. Thecombustionairductsystemmustbemadeofmetal. Itmustpermitzeroclearancetocombustibleconstructionandpreventmaterialfromdroppingintotheinletorintotheareabeneaththedwellingandcontainarodentscreen.

3. Theappliancemustbesecuredtothemobilehomestructurebyboltingittothefloor(usinglagbolts).Usethesameholesthatsecuredtheappliancetotheshippingpallet.

4. Theappliancemustbegroundedwith#8solidcopperground-ingwireorequivalent,terminatedateachendwithanNECapprovedgroundingdevice.

5. Refer toClearances toCombustibles and floor protectionrequirementsonpage 8forlistingstocombustiblesandappro-priatechimneysystems.

6. Usesiliconetocreateaneffectivevaporbarrierattheloca-tionwherethechimneyorothercomponentpenetratestotheexteriorofthestructure.

7. Followthechimneymanufacturer’sinstructionswheninstallingtheventsystemforuseinamobilehome.

8. InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.

NEVERINSTALLINASLEEPINGROOM.

WARNING

Spark Arestor Cap

Roof Flashing

Storm Collar

Joist Shield/Firestop Double Wall Connector Pipe

Figure 24.1

CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage

CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Anysupportingmaterialthatwouldaffectthestructural

integrity.

Thisapplianceistobeconnectedtoafactory-builtchimneyconformingtoCAN/ULC-S629,Standardfor650°CFacto-ry-BuiltChimneys.

Forremovalofthechimneyformobilehometransportation,contactthepropertransportationofficials.

WARNINGProductsofcombustiongeneratecarbonmonoxideand

differentfuelsgeneratedifferentlevels.Carbonmonoxide• Onlyuseapprovedfuelsinthisappliance.• Alwayskeepdoorshutduringoperation.Operatingthis

appliancewithdoorsopencanallowCOtoleakintothehome.

COcankillyoubeforeyouareawareitisinyourhome.Atlowerlevelsofexposure,COcausesmildeffectsthatareoftenmistakenfortheflu.Thesesymptomsincludeheadaches,dizziness,disorientation,nauseaandfatigue.TheeffectsofCOexposurecanvarygreatlyfrompersontopersondependingonage,overallhealthandtheconcentrationandlengthofexposure.

WARNINGIt is critical to have a working smoke detector installed in the home of appliance operation.

• Smokealarmsthatareproperlyinstalledandmaintainedplayavitalroleinreducingfiredeathsandinjuries.Havingaworkingsmokealarmreducesthechanceoffirerelatedinjuries..

Page 25: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 25

SANTA FE PELLET INSERT

8 Reference MaterialsA. Service & Maintenance List

Date of Service Performed By Description of Service

Page 26: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

26 7019-230H January 4, 2018

SANTA FE PELLET INSERT

Date of Service Performed By Description of Service

Page 27: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

January 4, 2018 7019-230H 27

SANTA FE PELLET INSERT

Service PartsR

SANTAFEI-MBKBeginning Manufacturing Date: Dec. 2009

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.

Stocked at Depot

ITEM DESCRIPTION COMMENTS PART NUMBERHopper Switch Magnet Bracket SRV7019-217 Y

Magnetic Switch SRV7000-375 YMagnet Round SRV7000-140 YPlate, Ash Cleanout 7001-186

Wire Harness Hopper Switch SRV414-1220 YACCESSORIES

Adjustable Hearth Support12” x 50”, 2-10” H ADJSPT-12

No longer available 841-0990

Log Set LOGS-30-OE

Log, Rear Left 7050-144

Log , Rear Right 7050-143

Outside Air Kit, Rear 811-0872

Channel, Air Intake SRV413-7040

Cover, Outside Air Kit, Floor 411-1071

Hose, Alum Flex, 2 Inch X 3 Ft SRV200-0860

Outside Air Cap Assembly 7001-044

Outside Air Collar Assembly SRV7001-045

Trim Plate, Outside Air Kit 412-7100

Panel Set, Large

Black Nickel SP-SFI3350-NB

No longer available SP-SFI3350-GD

Nickel SP-SFI3350-NL

Bracket, -L-, Trim 832-0840

Logo, Quadra-Fire Pkg of 10 7000-649/10

Trim, Panel SetBlack Nickel 7019-027

Gold SRV250-4660

Panel Set, Small

Black Nickel SP-SFI3040-NB

No longer available SP-SFI3040-GD

Nickel SP-SFI3040-NL

Bracket, -L-, Trim 832-0840

Logo, Quadra-Fire Nickel 7000-649/10

Trim, Panel Set, StdBlack Nickel 7019-026

Gold 811-0710

Reset Button Assembly SRV7000-040

Smart-Batt Il 841-0970

Smart-Stat Il 841-0960

Thermostat WALL-STAT YThermostat, Programmable WALL-STATP

Vent Adapter, 3-4” 811-0720

Additional service part numbers appear on following page.

B. Accessory List

Page 28: Installation Manual - Hearth N Homedownloads.hearthnhome.com/installmanuals/SANTAFEI_MBK_PELLET...E. Install Checklist ... Laboratory OMNI Test Laboratories, Inc. ... Since pellet

28 7019-230H January 4, 2018

CONTACT INFORMATION

Hearth & Home Technologies352 Mountain House Road

Halifax, PA 17032Division of HNI INDUSTRIES

Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer

log onto www.quadrafire.com

DO NOT DISCARD THIS MANUALCAUTION

• Important operating and maintenance instruc-tions included.

• Leave this manual with party responsible for use and operation.

• Read, understand and follow these instruc-tions for safe installa-tion and operation.

DO NOTDISCARD

We recommend that you record the following pertinent information for your heating appliance.

Date purchased/installed:_________________________________________________________________________

Serial Number:____________________________________ Location on appliance:___________________________

Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______

Notes:________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 or other U.S. and foreign patents pending.