installation manual optika -minilaneinstallation manual optika -minilane seilusaoptmontage.doc...
TRANSCRIPT
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 1 von 1
1
Installation manual OPTIKA -Minilane
Content
1. Overview
2. Wiring of the devices
3. HiVoltage-Box
3.1. Single phase
3.2. Two phases
3.3. Three phases
4. The components
4.1. Interface to the pinsetter
4.2. Wiring of the components on the RS485 bus
4.3. Wiring Hivoltage Box – Interface
4.4. Wiring Interface - Pinsetter
5. Interface to the pinsetter
6. Lanecomputer
7. Settings on Lanecomputer
8. Attachment A (In- und Outputs on the Seil-Interface)
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 2 von 2
2
1. Overview
Overview
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 3 von 3
3
2. Control Unit
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 4 von 4
4
3. HiVoltageBox
3.1. Single phase
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 5 von 5
5
3.2. Two phases
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 6 von 6
6
3.3. Three phases
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 7 von 7
7
4. The components
4.1. Interface to the pinsetter
Interface for
Lane 2:
Jumper is set
If this interace is last
component on the cat5-bus:
All 3 Jumpers are set
(Termination Jumpers)
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 8 von 8
8
4.1. Lanecomputer
VGA-Monitor Lane 2
(LCD-TV )
VGA-Monitor Lane 1
(LCD-TV)
Network-Plug
CCS2000 – Communication bus
1 = -
2 = +
Plug for RS485 bus (to the interfaces)
3 = -
4 = +
5 = Earth (GND)
NOTE: The Plugs on the interfaces have 5
wires !!
Use only wires 3,4,5
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 9 von 9
9
(Lanecomputer)
4.2. Wiring of the components on the RS485 bus
Interface-(or Coin-Interface) Interface Lane 1 Interface Lane 2 Lanepc
(Wiring of the components on the RS485 bus)
Note:
On the interafce for lane 2: Set the jumper (see 4. Interface for the pinsetter)
On the last component on the bus (either interface for the pinsetter or coin-interface) set the
termination jumpers. In the example above this is the coin-interface.
Cat-5 cable
1+2 = 12V AC
3=Communication (-)
4=Communication (+)
5=Earth (GROUND)
Cat-3 cable
3=Communication (-)
4=Communication (+)
5=Earth (GROUND)
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 10 von 10
10
4.3 Wiring Hivoltage Box - Interface
3pins plug
Common elevator
4pins plug
1,2 Ballcounter
3,4 Remote Manager Switch
To the pinsetter(s) To the HiVo Box
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 11 von 11
11
4.4 Wiring Interface - Pinsetter
(Interface to pinsetter)
Cable to pinsetter
36pin flat cable
Cable to motor
control
14pin flat cable
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 12 von 12
12
PPPP RRRR OOOO GGGG PPPP
5. Lanecomputer Setup
OPTIKA supports various types of pinsetters in different countries, with
different needs and requirements. To achive this the systems offers many options and features for
customization. For Minilane bowling (for pinsetters with strings) the most important settings are
pointed out below.
Entering the setup mode using a standard BMS-Keyboard:
Hold down the „Eye“ buttohn and
type:
When a standard PC-Keyboard is used (PS-2 only):
Hold down the “Shift” button and press “PROGP”
Navigation:
Use the arrow keys for navigation:
or: or: or:
When a standard PC-Keyboard is used (PS-2 only):
Use the arrow buttons
Selection:
Press „Start“ :
When a standard PC-Keyboard is used (PS-2 only):
Press the “PageUp” button
START
RT
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 13 von 13
13
Setupscreen
Note: The appropriate setup is usually made from factory. Do not change or modify them if not
necessary.
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 14 von 14
14
Subject Default value Important
for Minilane
measuring delay ball 1+2[ms] 1500 Yes
Lane number (left) 1 (or 3 or 5..) Yes
language English Yes
top-5 (automatic top-5 management) 1 Yes
graphic-Set 0 No
distance of photocells 30 No
display of graphics 0-3 Open+League No
display of ball speed No No
keyboard USA No
handicap 200 75 60 No
showtime picture [sec]: max. timeout for graphics 6 Yes
speedlimit 0 No
showtime waitpictures [sec]: display time for graphics
when system is idle
19 Yes
Time delay between ball
passes the photocell and
machine is starting impuls
Lanenumber (left lane only)
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 15 von 15
15
Subject Default value Important
for Minilane
show scrolltext 1 Yes
speed 0 No
pulstime trigger relay 1000 No
pulstime set relay 1000 No
pulstime set relay (10th
frame) 12000 No
puls set relay 0 No
ON-time set relay 5000 No
OFF-time set relay 1000 No
pulstime stepper1-relay 1000 No
pulstime stepper2-relay 1000 No
pulstime ball lift-relay [sec] (relay time for preference
when ball passes the photocell)
180 Yes
bumper-relay: Puls=1; Cont=0 0 Yes
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 16 von 16
16
Subject Default value Important
for Minilane
pulstime bumper-relay [msec] 999 No
pulstime call relay [sec] 10 No
delay time pinsetter OFF [sec] 10 No
time for practice [min] 10 No
pinsetter sets in practice 1 No
automatic correction 0 No
count frame 11/12 0 No
monitor: VGA=2 15khz=1 25Khz=0 2 No
pulstime stepper3-relay 1000 No
pinsetter A-2/S=1 GSxx=2 0 No
foul set: 0=normal; 1=A-2 0 No
block keyb. After name entry(0,1) 0 No
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 17 von 17
17
Subject Default value Important
for Minilane
pinsetter ON/OFF Relay 2 Yes
trigger No No
set No No
stepper 1 No No
stepper 2 No No
stepper 3 No No
Ball lift Relay 5 Yes
bumper Relay 3 Yes
call No No
set 10th
frame No No
Relay 2nd
ball-lamp No No
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 18 von 18
18
Subject Default value Important
for Minilane
foul input No No
2nd
throw input No No
free input No No
sweeper input No No
3rd serial port No No
IRT No No
TCP/IP (0,1) 1 Yes
IP (Port 23)
This address depends on the lanenumber
defaults:
lane 1+2 : 192.168.001.020
lane 3+4 : 192.168.001.021
lane 5+6 : 192.168.001.022
..
192.168.001.020
(12 digits notation
required !)
Yes
counter (build-in counters) No
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 19 von 19
19
Subject Default value Important
for Minilane
foul inversion 0 No
max. 6 player (limit number of players to 6) 0 Yes
prepaid: timeout[s] (Delay at game end before switching
to idle. Only for prepaid games
60 Yes
bungee timeout No No
delay PinRel. After O [ms]
delay for the spick
50 Yes
Stop in O
0: no, stop only after detangle
1: Always stop in O
0 Yes
No, foul or Fast-Reset 0 No
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 20 von 20
20
Attachment A (In- and Outputs on the interface)
Inputs :
Input
1 Photocell
2 Detangle
3 ON/OFF
4 U-Signal
5 O-Signal
Outputs:
Rel.
1 Pinsetter-Motor
2 ON/OFF
3 Bumper
4 CrossLight
5 Ball-Lift
6 TrainLight
Additional Relais ChaseLight
Installation manual OPTIKA -Minilane
SeilUSAoptmontage.doc
Version 1.0
Seite 21 von 21
21
- SWITCH OFF POWER before any manipulation !
IMPORTANT: